RESUMO
The purpose of this study was to estimate the radiation exposure of children, during cardiac catheterisations for the diagnosis or treatment of congenital heart disease. Radiation doses were estimated for 45 children aged from 1 d to 13 y old. Thermoluminescent dosemeters (TLDs) were used to estimate the posterior entrance dose (DP), the lateral entrance dose (DLAT), the thyroid dose and the gonads dose. A dose-area product (DAP) meter was also attached externally to the tube of the angiographic system and gave a direct value in mGy cm2 for each procedure. Posterior and lateral entrance dose values during cardiac catheterisations ranged from 1 to 197 mGy and from 1.1 to 250.3 mGy, respectively. Radiation exposure to the thyroid and the gonads ranged from 0.3 to 8.4 mGy to 0.1 and 0.7 mGy, respectively. Finally, the DAP meter values ranged between 360 and 33,200 mGy cm2. Radiation doses measured in this study are comparable with those reported to previous studies. Moreover, strong correlation was found between the DAP values and the entrance radiation dose measured with TLDs.
Assuntos
Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/radioterapia , Radiometria/métodos , Adolescente , Aorta/metabolismo , Calibragem , Criança , Pré-Escolar , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Lactente , Recém-Nascido , Radiação , Doses de Radiação , Radiografia Intervencionista , Dosimetria TermoluminescenteRESUMO
Radiation protection and estimation of the radiological risk in paediatric radiology is essential due to children's significant radiosensitivity and their greater overall health risk. The purpose of this study was to estimate the organ and effective doses of paediatric patients undergoing barium meal (BM) examinations and also to evaluate the assessment of radiation Risk of Exposure Induced cancer Death (REID) to paediatric patients undergoing BM examinations. During the BM studies, fluoroscopy and multiple radiographs are involved. Since direct measurements of the dose in each organ are very difficult if possible at all, clinical measurements of dose-area products (DAPs) and the PCXMC 2.0 Monte Carlo code were involved. In clinical measurements, DAPs were assessed during examination of 51 patients undergoing BM examinations, separated almost equally in three age categories, neonatal, 1- and 5-y old. Organs receiving the highest amounts of radiation during BM examinations were as follows: the stomach (10.4, 10.2 and 11.1 mGy), the gall bladder (7.1, 5.8 and 5.2 mGy) and the spleen (7.5, 8.2 and 4.3 mGy). The three values in the brackets correspond to neonatal, 1- and 5-y-old patients, respectively. For all ages, the main contributors to the total organ and effective doses are the fluoroscopy projections. The average DAP values and absorbed doses to patient were higher for the left lateral projections. The REID was calculated for boys (4.8 × 10(-2), 3.0 × 10(-2) and 2.0 × 10(-2) %) for neonatal, 1- and 5-y old patients, respectively. The corresponding values for girl patients were calculated (12.1 × 10(-2), 5.5 × 10(-2) and 3.4 × 10(-2) %).
Assuntos
Envelhecimento/fisiologia , Fluoroscopia , Modelos Estatísticos , Doses de Radiação , Vísceras/fisiologia , Contagem Corporal Total/métodos , Absorção de Radiação , Administração Oral , Bário/administração & dosagem , Pré-Escolar , Simulação por Computador , Meios de Contraste/administração & dosagem , Humanos , Lactente , Recém-Nascido , Masculino , Método de Monte Carlo , Especificidade de Órgãos/fisiologia , SoftwareRESUMO
Patient dose measurements of local entrance dose to the skin have been carried out using radiochromic film (Gafchromic XR-RV2) in a sample of interventional procedures. The major aim of the work was to measure patient entrance dose from such examinations using Gafchromic XR-RV2. Forty-five various interventional procedures (including nefrostomies and urinary stenting, biliary stenting and percutaneous transhepatic biliary drainage (PTBD) and aorta stent grafting) were evaluated. Maximum entrance doses were 537 ± 119 mGy in nephrostomies, 943 ± 631 mGy in biliary stenting and PTBD and 2425 ± 569 mGy in aorta stent grafting. Results indicate that all patients undergoing aorta stent grafting received skin dose above 1500 mGy, which means that there is an increasing potential to suffer radiation-induced skin injuries. The film provides dose mapping, the position of the skin area with highest dose and can be used for immediate qualitative and as well as for quantitative assessment of patient skin dose.