Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Obstet Gynaecol ; 37(8): 1076-1081, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28760055

RESUMO

Caesarean scar defect (CSD) can cause postmenstrual bleeding. Defect repair is an effective technique to improve this symptom, but there are still a few patients getting little improvement. This retrospective study evaluates the efficacy of scar repair and explores the factors associated with poor effect. In total, 123 patients were involved in the final analysis. All of them complained about menstruation period >7 days due to postmenstrual bleeding. Before surgery, 87.8% of patients had a menstruation period more than 10 days and 20.3% had a period more than 15 days. After surgery, a normal menstruation period (< =7 days) was achieved in 46.3% (95%CI 37.3%-55.6%) of patients and a menstruation period lasting no more than 10 days was achieved in 74.8% (95%CI 66.2%-82.2%). Through multivariate logistic analysis, four factors were found dependently associated with poor effect (defined as menstruation period >10 days after surgery): repeated caesarean section (OR 9.75, 95%CI 2.30-41.36, 0.002) was a risk factor, while defect volume >600 mm3 (OR 0.14, 95%CI 0.03-0.56, 0.006), interval from caesarean section to symptom emerging >3 months (OR 0.25, 95%CI 0.07-0.94, 0.041) and straight or retroflexed uterus (OR 0.19, 95%CI 0.05-0.79, 0.022) were protective factors. Impact statement What is already known on this subject? Caesarean scar defect can cause postmenstrual bleeding. Defect repair can improve this symptom, but there are still a few patients getting little improvement after surgery. What do the results of this study add? Defect volume >600 mm3, interval from caesarean section to symptom emerging >3 months and straight or retroflexed uterus are protective factors of poor effect (defined as menstruation period >10 days after surgery), and repeated caesarean section is a risk factor. What are the implications of these findings for clinical practice and/or further research? These findings may help in counselling the patients and in medical decision. Further researches are needed to explore other factors associated with surgical effect and build prediction models.


Assuntos
Cesárea/efeitos adversos , Cicatriz/cirurgia , Menstruação , Hemorragia Uterina/terapia , Adulto , Recesariana/efeitos adversos , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia , Hemorragia Uterina/epidemiologia
2.
J Biomed Biotechnol ; 2011: 917232, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22203787

RESUMO

A procedure for simultaneous identification and quantification of canrenone and its biotransformed product 11-α-hydroxy-canrenone by high-performance liquid chromatography with ultraviolet detector (HPLC-UVD) and mass spectrometry (LC-MS) methods was proposed. The optimal determination variables on the HPLC-UVD or LC-MS coupled with a ZORBAX Eclipse XDB-C18 column (150 mm × 4.6 mm, 5 µm) were set as follows: detection wavelength of 280 nm, mobile phase of water and methanol gradient elution, temperature for the chromatographic column of 30°C, flow rate of mobile phase of 0.8 mL/min, sample injection volume of 5 µL, and elution time of 40 min. The MS conditions were set as follows: the flow rate of sheath gas, aux gas, and sweep gas were kept at 35 arb, 5 arb, and 0 arb, respectively. The temperature of capillary was held at 300°C, and capillary voltage was set at 30.00 V. Tube lens were performed at 100.00 V. The proposed method was validated by linearity (r² ≥ 0.9910), average recovery (94.93%, RSD1.21%), precision (RSD ≤ 1.31%), limit of detection, and limit of quantification (LOD 0.1~0.12 mg/L, LOQ 0.5~0.67 mg/L), which proved to be affordable for simultaneously determining canrenone and its bio-transformed product 11-α-hydroxy-canrenone.


Assuntos
Canrenona/análogos & derivados , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Biotransformação , Canrenona/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA