Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Analyst ; 149(10): 2784-2795, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38647233

RESUMO

Patients with end-stage kidney disease (ESKD) rely on dialysis to remove toxins and stay alive. However, hemodialysis alone is insufficient to completely remove all/major uremic toxins, resulting in the accumulation of specific toxins over time. The complexity of uremic toxins and their varying clearance rates across different dialysis modalities poses significant challenges, and innovative approaches such as microfluidics, biomarker discovery, and point-of-care testing are being investigated. This review explores recent advances in the qualitative and quantitative analysis of uremic toxins and highlights the use of innovative methods, particularly label-mediated and label-free surface-enhanced Raman spectroscopy, primarily for qualitative detection. The ability to analyze uremic toxins can optimize hemodialysis settings for more efficient toxin removal. Integration of multiple omics disciplines will also help identify biomarkers and understand the pathogenesis of ESKD, provide deeper understanding of uremic toxin profiling, and offer insights for improving hemodialysis programs. This review also highlights the importance of early detection and improved understanding of chronic kidney disease to improve patient outcomes.


Assuntos
Falência Renal Crônica , Insuficiência Renal Crônica , Toxinas Urêmicas , Humanos , Falência Renal Crônica/terapia , Insuficiência Renal Crônica/terapia , Insuficiência Renal Crônica/diagnóstico , Toxinas Urêmicas/análise , Progressão da Doença , Análise Espectral Raman/métodos , Biomarcadores/análise , Biomarcadores/sangue , Diálise Renal
2.
Angew Chem Int Ed Engl ; 63(23): e202403317, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38578721

RESUMO

We demonstrate directed translocation of ClO4 - anions from cationic to neutral binding site along the synthetized BPym-OH dye molecule that exhibits coupled excited-state intramolecular proton-transfer (ESIPT) and charge-transfer (CT) reaction (PCCT). The results of steady-state and time-resolved spectroscopy together with computer simulation and modeling show that in low polar toluene the excited-state redistribution of electronic charge enhanced by ESIPT generates the driving force, which is much stronger than by CT reaction itself and provides more informative gigantic shifts of fluorescence spectra signaling on ultrafast ion motion. The associated with ion translocation red-shifted fluorescence band (at 750 nm, extending to near-IR region) appears at the time ~83 ps as a result of electrochromic modulation of PCCT reaction. It occurs at substantial delay to PCCT that displayed fluorescence band at 640 nm and risetime of <200 fs. Thus, it becomes possible to visualize the manifestations of light-triggered ion translocation and of its driving force by fluorescence techniques and to separate them in time and energy domains.

3.
Clin Kidney J ; 17(1): sfad304, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38213491

RESUMO

Background: Intradialytic hypotension (IDH) is a common hemodialysis complication causing adverse outcomes. Despite the well-documented associations of ambient temperatures with fluid removal and pre-dialysis blood pressure (BP), the relationship between ambient temperature and IDH has not been adequately studied. Methods: We conducted a cohort study at a tertiary hospital in southern Taiwan between 1 January 2016 and 31 October 2021. The 24-h pre-hemodialysis mean ambient temperature was determined using hourly readings from the weather station closest to each patient's residence. IDH was defined using Fall40 [systolic BP (SBP) drop of ≥40 mmHg] or Nadir90/100 (SBP <100 if pre-dialysis SBP was ≥160, or SBP <90 mmHg). Multivariate logistic regression with generalizing estimating equations and mediation analysis were utilized. Results: The study examined 110 400 hemodialysis sessions from 182 patients, finding an IDH prevalence of 11.8% and 10.4% as per the Fall40 and Nadir90/100 criteria, respectively. It revealed a reverse J-shaped relationship between ambient temperature and IDH, with a turning point around 27°C. For temperatures under 27°C, a 4°C drop significantly increased the odds ratio of IDH to 1.292 [95% confidence interval (CI) 1.228 to 1.358] and 1.207 (95% CI 1.149 to 1.268) under the Fall40 and Nadir90/100 definitions, respectively. Lower ambient temperatures correlated with higher ultrafiltration, accounting for about 23% of the increased IDH risk. Stratified seasonal analysis indicated that this relationship was consistent in spring, autumn and winter. Conclusion: Lower ambient temperature is significantly associated with an increased risk of IDH below the threshold of 27°C, irrespective of the IDH definition. This study provides further insight into environmental risk factors for IDH in patients undergoing hemodialysis.

4.
Adv Sci (Weinh) ; : e2404725, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39078745

RESUMO

Lately, carbazole-based self-assembled monolayers (SAMs) are widely employed as effective hole-selective layers (HSLs) in inverted perovskite solar cells (PSCs). Nevertheless, these SAMs tend to aggregate in solvents due to their amphiphilic nature, hindering the formation of a monolayer on the ITO substrate and impeding effective passivation of deep defects in the perovskites. In this study, a series of new SAMs including DPA-B-PY, CBZ-B-PY, POZ-B-PY, POZ-PY, POZ-T-PY, and POZ-BT-PY are synthesized, which are employed as interfacial repairers and coated atop CNph SAM to form a robust CNph SAM@pseudo-planar monolayer as HSL in efficient inverted PSCs. The CNph SAM@pseudo-planar monolayer strategy enables a well-aligned interface with perovskites, synergistically promoting perovskite crystal growth, improving charge extraction/transport, and minimizing nonradiative interfacial recombination loss. As a result, the POZ-BT-PY-modified PSC realizes an impressively enhanced solar efficiency of up to 24.45% together with a fill factor of 82.63%. Furthermore, a wide bandgap PSC achieving over 19% efficiency. Upon treatment with the CNph SAM@pseudo-planar monolayer, also demonstrates a non-fullerene organic photovoltaics (OPVs) based on the PM6:BTP-eC9 blend, which achieves an efficiency of 17.07%. Importantly, these modified PSCs and OPVs all show remarkably improved stability under various testing conditions compared to their control counterparts.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA