Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 160
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Oral Investig ; 26(3): 2965-2973, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34812958

RESUMO

OBJECTIVES: The FTO gene has been reported as an obesity-associated gene and is also considered a risk gene for osteoarthritis (OA). However, its exact function is unclear, and there is conflicting evidence on the involvement of FTO polymorphisms in OA via obesity. The purpose of this study was to determine the effects of FTO polymorphism rs8044769 alleles on OA in the temporomandibular joint (TMJ), which is minimally affected by body weight. MATERIALS AND METHODS: A total of 324 TMJs (113 with OA and 211 without OA, serving as controls) from 162 Japanese patients with temporomandibular disorders and undergoing MRI examination were analyzed. Genotyping was conducted, and multivariate analysis was performed after adjusting for the effects of age, sex, body mass index, and TMJ disc abnormalities. RESULTS: Mean age, BMI, and sex did not differ between the TMJs with OA and the TMJs without OA, but a significant difference was found for positional and dynamic disc abnormalities (P < 0.05). The allele frequency of FTO polymorphisms also differed significantly between the TMJs with OA and the TMJs without OA (P = 0.011). Moreover, logistic regression analysis showed no significant association between BMI (P = 0.581) and the occurrence of TMJOA but also indicated that the CC allele of rs8044769 is a risk factor for TMJOA (P = 0.040). CONCLUSIONS: Our results show that rs8044769 in the FTO gene might be involved in TMJOA. CLINICAL RELEVANCE: The present study provides a basis for a deeper understanding of the mechanism underlying degenerative skeletal diseases and the more effective selection and development of treatment strategies based on the patients' genetic characteristics.


Assuntos
Osteoartrite , Transtornos da Articulação Temporomandibular , Dioxigenase FTO Dependente de alfa-Cetoglutarato/genética , Humanos , Polimorfismo Genético/genética , Articulação Temporomandibular , Disco da Articulação Temporomandibular , Transtornos da Articulação Temporomandibular/genética
2.
J Esthet Restor Dent ; 34(4): 583-591, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35182447

RESUMO

OBJECTIVE: This case report describes the orthodontic and prosthetic rehabilitation of a patient with resorption of the roots of the maxillary central incisors due to the ectopic maxillary canines. CLINICAL CONSIDERATIONS: A 16-year-old woman presented with severe resorption of the roots of the maxillary central incisors due to the ectopic maxillary canines. The impacted canines were orthodontically tracted with a lingual arch-supporting temporary central incisors and vertical elastics, and, undesirable root proximity was later corrected by moving the canines distally 1.5 mm apart. Gingival replacement cords were placed into the gingival sulcus of the canines, and tooth preparation was performed along with rotary gingival curettage of the interdental papilla. Convex form was provided for the mesial and labio-distal subgingival contour of the restorations. CONCLUSIONS: The creeping attachment of the interdental papilla was successfully achieved by the orthodontic arrangement of interdental distance and the prosthetic stimulus via the retraction cord, rotary curettage, and convex mesial subgingival contours. In addition, selective retraction of the labio-distal gingiva by overcontoured restorations moved the gingival zenith position (GZP) distally. Finally, the canine crown morphology and gingival level mimicked the central incisors. CLINICAL SIGNIFICANCE: This clinical report introduces a treatment workflow of to recover the esthetic disturbance due to severe root resorption of the maxillary central incisors associated with impacted maxillary canines. The present orthodontic and prosthetic procedure can improve both hard and soft tissue esthetics and could be used in similar cases, such as malformed teeth and tooth autotransplantation or transposition with disturbances in the interdental papilla height or the GZP.


Assuntos
Reabsorção da Raiz , Dente Impactado , Adolescente , Dente Canino , Humanos , Incisivo/anatomia & histologia , Maxila , Reabsorção da Raiz/terapia , Dente Impactado/complicações , Dente Impactado/terapia
3.
J Oral Rehabil ; 48(4): 375-383, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33372318

RESUMO

Dynamic articular disc abnormality (wR, with reduction; woR, without reduction) is well known as the risk factor for temporomandibular joint osteoarthritis (TMJOA). However, there are few speculations on the potential risk of positional disc abnormalities for TMJOA. The purpose of this study was to investigate the relative risk of positional abnormality and dynamic abnormality of the temporomandibular disc for OA after the three-dimensional interpretation of all the sagittal and coronal planes of magnetic resonance (MR) data in a large dataset of consecutive subjects. Experimental samples consisted of images of 1356 TMJs of patients. A diagnosis of disc state was established in each TMJ utilising a 1.5T MR imaging scanner. A binary logistic regression analysis was performed to identify the significant associations between the outcome (dependent variable: the presence of OA) and the predictors (covariates: age, sex, dynamic disc state [the presence of woR], and 5 categories of the positional disc state [NA, no abnormality; SW, sideways; pADD, partial anterior; cADD, complete anterior; PDD, posterior]). Based on the result of the binary logistic regression analysis, the presence of woR showed an odds ratio of 14.1 (P < .05). In addition, compared with the joints NA, those with SW and cADD showed odds ratios of 5.62 and 10.88, respectively (P < .05). Despite the limitations of the study, in the positional disc abnormalities, sideways disc displacement and complete anterior disc displacement could be associated with the occurrence of TMJOA. All the coronal and sagittal MR images should be evaluated to assess intra-articular joint disorders accurately.


Assuntos
Luxações Articulares , Osteoartrite , Transtornos da Articulação Temporomandibular , Humanos , Imageamento por Ressonância Magnética , Osteoartrite/diagnóstico por imagem , Risco , Articulação Temporomandibular , Disco da Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/diagnóstico por imagem
4.
J Prosthodont ; 28(2): e477-e484, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29194841

RESUMO

PURPOSE: Intraoral digital scanning can accurately record single abutment tooth preparations despite their geometry, and the algorithms of the CAD software can be set to manage different abutment forms. The purpose of this in vitro study was to evaluate the marginal and internal fit of CAD/CAM zirconia crowns fabricated over conventional and reverse-tapered preparations. MATERIALS AND METHODS: Crown preparations with known total occlusal convergence (TOC) angles (-8°, -4°, 0°, 8°, 12°, 16°, and 22°) were digitally created from a maxillary left central incisor and printed in acrylic resin. Next, casts were scanned with a TRIOS intraoral scanner, and crowns were designed with KaVo multiCAD software using default parameters (50 µm cement space) on abutments with positive TOC angles, whereas reverse-tapered abutments (negative TOC angles) were digitally blocked out at 0° and had an extra mesiodistal gap set to 50 µm. Then, zirconia crowns were fabricated, and their marginal and internal discrepancies were recorded with the silicone replica technique. All replicas were examined under a stereomicroscope at 50× magnification. Collected data were analyzed with one-way ANOVA and post hoc Tukey test for marginal fit. For the axial and incisal fit, measured values did not follow a normal distribution; therefore, the Kruskal-Wallis and the Dunn/Bonferroni multiple comparison tests were applied (p = 0.05). RESULTS: The mean marginal fit of -8° crowns (58.2 ± 6.0 µm) was statistically different (p < 0.0001) from all the remaining crowns (range 42.1-47.3 µm). Also, the internal fit was statistically significant when comparing crowns fabricated over abutments with positive and negative TOC angles (p < 0.0001). The largest median axial discrepancies were found in the -8° (165.5 µm) and -4° (130.8 µm) groups; however, when evaluating the incisal fit, they showed the smallest discrepancies (67.3 and 81.8 µm, respectively). CONCLUSIONS: Under the conditions of this study, the marginal and internal fit of zirconia crowns fabricated over inverse-tapered preparations is within clinically accepted values.


Assuntos
Desenho Assistido por Computador , Coroas , Planejamento de Prótese Dentária/métodos , Imageamento Tridimensional/métodos , Algoritmos , Técnica de Moldagem Odontológica , Adaptação Marginal Dentária , Materiais Dentários , Humanos , Incisivo , Maxila , Software , Zircônio
5.
Biochem Biophys Res Commun ; 496(1): 83-88, 2018 01 29.
Artigo em Inglês | MEDLINE | ID: mdl-29305867

RESUMO

The calcineurin/nuclear factor of activated T cell (NFAT) signaling pathway plays a major role in osteoclast differentiation; however, the proteins that react with the calcineurin-NFAT complex in osteoclasts to regulate osteoclastogenesis remain unclear. Here, we present evidence that PICK1 also positively regulates calcineurin B in osteoclasts to activate NFAT to promote osteoclastogenesis. mRNA and protein expression of PICK1 in murine primary bone marrow macrophages (BMMs) was significantly increased during RANKL-induced osteoclast differentiation. The interaction of PICK1 with calcineurin B in BMMs was confirmed by co-immunoprecipitation. An inhibitor of the PICK1 PDZ domain significantly decreased osteoclastogenesis marker gene expression and the number of TRAP-positive multinucleated cells among RAW264.7 osteoclast progenitor cells. Overexpression of PICK1 in RAW264.7 cells significantly increased the number of TRAP-positive mature osteoclasts. Increased NFAT activation with transcriptional activation of PICK1 during RAW264.7 osteoclastogenesis was also confirmed in a tetracycline-controlled PICK1 expression system. These results suggest that the PDZ domain of PICK1 directly interacts with calcineurin B in osteoclast progenitor cells and promotes osteoclast differentiation through activation of calcineurin-NFAT signaling.


Assuntos
Calcineurina/metabolismo , Proteínas de Transporte/metabolismo , Fatores de Transcrição NFATC/metabolismo , Proteínas Nucleares/metabolismo , Osteoclastos/citologia , Osteoclastos/fisiologia , Osteogênese/fisiologia , Domínios PDZ/fisiologia , Animais , Sítios de Ligação , Proteínas de Ciclo Celular , Diferenciação Celular/fisiologia , Camundongos , Ligação Proteica , Domínios Proteicos , Células RAW 264.7
6.
J Sleep Res ; 27(4): e12608, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-28960626

RESUMO

Rhythmic masticatory muscle activity can be a normal variant of oromotor activity, which can be exaggerated in patients with sleep bruxism. However, few studies have tested the possibility in naturally sleeping animals to study the neurophysiological mechanisms of rhythmic masticatory muscle activity. This study aimed to investigate the similarity of cortical, cardiac and electromyographic manifestations of rhythmic masticatory muscle activity occurring during non-rapid eye movement sleep between guinea pigs and human subjects. Polysomnographic recordings were made in 30 freely moving guinea pigs and in eight healthy human subjects. Burst cycle length, duration and activity of rhythmic masticatory muscle activity were compared with those for chewing. The time between R-waves in the electrocardiogram (RR interval) and electroencephalogram power spectrum were calculated to assess time-course changes in cardiac and cortical activities in relation to rhythmic masticatory muscle activity. In animals, in comparison with chewing, rhythmic masticatory muscle activity had a lower burst activity, longer burst duration and longer cycle length (P < 0.05), and greater variabilities were observed (P < 0.05). Rhythmic masticatory muscle activity occurring during non-rapid eye movement sleep [median (interquartile range): 5.2 (2.6-8.9) times per h] was preceded by a transient decrease in RR intervals, and was accompanied by a transient decrease in delta elelctroencephalogram power. In humans, masseter bursts of rhythmic masticatory muscle activity were characterized by a lower activity, longer duration and longer cycle length than those of chewing (P < 0.05). Rhythmic masticatory muscle activity during non-rapid eye movement sleep [1.4 (1.18-2.11) times per h] was preceded by a transient decrease in RR intervals and an increase in cortical activity. Rhythmic masticatory muscle activity in animals had common physiological components representing transient arousal-related rhythmic jaw motor activation in comparison to human subjects.


Assuntos
Mastigação/fisiologia , Músculos da Mastigação/fisiologia , Bruxismo do Sono/fisiopatologia , Sono/fisiologia , Adulto , Animais , Nível de Alerta/fisiologia , Eletrocardiografia/métodos , Eletroencefalografia/métodos , Eletromiografia/métodos , Feminino , Cobaias , Humanos , Masculino , Bruxismo do Sono/diagnóstico , Especificidade da Espécie , Fatores de Tempo , Adulto Jovem
7.
Clin Oral Investig ; 21(1): 309-317, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27003278

RESUMO

OBJECTIVES: The aim of the present study was to evaluate the bonding effectiveness of two resin core buildup systems using conventional methods in the field of adhesive dentistry and a new non-destructive method. MATERIALS AND METHODS: Twenty-four single-rooted human teeth were built up with dual-cure one-step self-etch adhesive and composite systems (SY1: Clearfil DC bond and Clearfil DC core automix, SY2: Clearfil bond SE one and Clearfil DC core automix one). The prepared samples were sectioned into approximately 1 × 1-mm-thick beams and subjected to micro-tensile bond strength (µTBS) testing (n = 24). The fractured beams after µTBS testing were analyzed by SEM and energy-dispersive X-ray (EDX) spectrometry. The three teeth filled with each resin core system were sectioned and embedded in epoxy resin to observe the dentin-bonding interface under TEM (n = 6). Moreover, three of each resin core-filled teeth without any processing were examined using µCT (n = 6). RESULTS: Two-way ANOVA revealed that the two factors "root region" (p < 0.001, F = 15.22) and "system" (SY1 < SY2; p < 0.001, F = 22.52) had a significant influence. The µTBS gradually decreased from the coronal side to the apical side of the root canal. Morphological evaluation revealed that SY2 was superior in terms of resin curing at the apical side. µCT non-destructive evaluation clearly revealed gap formation in SY1. CONCLUSION: SY2, which included a new light-independent catalyst, showed better bonding effectiveness and adhesive interface to dentin compared to that of SY1. CLINICAL RELEVANCE: The new catalyst, which is activated by contact with adhesive and resin composite, can be used for resin core buildup restorations.


Assuntos
Adesivos Dentinários/química , Técnica para Retentor Intrarradicular , Cimentos de Resina/química , Humanos , Técnicas In Vitro , Teste de Materiais , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Espectrometria por Raios X , Propriedades de Superfície , Resistência à Tração , Microtomografia por Raio-X
8.
J Prosthet Dent ; 118(3): 392-399, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28222873

RESUMO

STATEMENT OF PROBLEM: Direct (intraoral) and indirect (desktop) digital scanning can record abutment tooth preparations despite their geometry. However, little peer-reviewed information is available regarding the influence of abutment tooth geometry on the accuracy of digital methods of obtaining dental impressions. PURPOSE: The purpose of this in vitro study was to evaluate the influence of abutment tooth geometry on the accuracy of conventional and digital methods of obtaining dental impressions in terms of trueness and precision. MATERIAL AND METHODS: Crown preparations with known total occlusal convergence (TOC) angles (-8, -6, -4, 0, 4, 8, 12, 16, and 22 degrees) were digitally created from a maxillary left central incisor and printed in acrylic resin. Each of these 9 reference models was scanned with a highly accurate reference scanner and saved in standard tessellation language (STL) format. Then, 5 conventional polyvinyl siloxane (PVS) impressions were made from each reference model, which was poured with Type IV dental stone scanned using both the reference scanner (group PVS) and the desktop scanner and exported as STL files. Additionally, direct digital impressions (intraoral group) of the reference models were made, and the STL files were exported. The STL files from the impressions obtained were compared with the original geometry of the reference model (trueness) and within each test group (precision). Data were analyzed using 2-way ANOVA with the post hoc least significant difference test (α=.05). RESULTS: Overall trueness values were 19.1 µm (intraoral scanner group), 23.5 µm (desktop group), and 26.2 µm (PVS group), whereas overall precision values were 11.9 µm (intraoral), 18.0 µm (PVS), and 20.7 µm (desktop). Simple main effects analysis showed that impressions made with the intraoral scanner were significantly more accurate than those of the PVS and desktop groups when the TOC angle was less than 8 degrees (P<.05). Also, a statistically significant interaction was found between the effects of the type of impression and the TOC angle on the precision of single-tooth dental impressions (F=2.43, P=.002). Visual analysis revealed that the intraoral scanner group showed a homogeneous deviation pattern across all TOC angles tested, whereas scans from the PVS and desktop scanner groups showed marked local deviations when undercuts (negative angles) were present. CONCLUSIONS: Conventional dental impressions alone or those further digitized with an extraoral digital scanner cannot reliably reproduce abutment tooth preparations when the TOC angle is close to 0 degrees. In contrast, digital impressions made with intraoral scanning can accurately record abutment tooth preparations independently of their geometry.


Assuntos
Coroas , Dente Suporte , Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica , Imageamento Tridimensional , Polivinil , Siloxanas , Desenho Assistido por Computador , Humanos , Modelos Dentários
9.
Pflugers Arch ; 467(7): 1445-1456, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25163765

RESUMO

We previously demonstrated that the deletion of phospholipase C-related catalytically inactive protein-1/2 (PRIP-1/2) enhances the desensitization of GABAA receptors (GABAARs), while it facilitates their resensitization at the offset of GABA puff, causing a hump-like tail current (tail-I) in layer 3 (L3) pyramidal cells (PCs) of the barrel cortex. In the present study, we investigated whether inhibitory synaptic transmission in L3 PCs in the barrel cortex is altered in the PRIP-1/2 double-knockout (PRIP-DKO) mice, and if so, how the interaction between excitation and inhibition is subsequently modified. PRIP-1/2 deletion resulted in the prolongation of the decay phase of inhibitory postsynaptic currents/potentials (IPSCs/IPSPs) in L3 PCs evoked by stimulation of L3, leaving the overall features of miniature IPSCs unchanged. An optical imaging revealed that the spatiotemporal profile of a horizontal excitation spread across columns in L2/3 caused by L4 stimulation in the barrel cortex was more restricted in PRIP-DKO mice compared to the wild type, while those obtained in the presence of bicuculline were almost identical between the two genotypes. These findings suggest that PRIP-1/2 deletion enhances the lateral inhibition by prolonging inhibitory synaptic actions to limit the intercolumnar integration in the barrel cortex. Considering the present findings together with our previous study including a mathematical simulation, the prolongation of inhibitory synaptic actions is likely to result from an enhancement of desensitization followed by an enhanced resensitization in GABAARs.


Assuntos
Proteínas Adaptadoras de Transdução de Sinal/metabolismo , Potenciais Pós-Sinápticos Inibidores , Peptídeos e Proteínas de Sinalização Intracelular/metabolismo , Células Piramidais/metabolismo , Córtex Somatossensorial/metabolismo , Proteínas Adaptadoras de Transdução de Sinal/genética , Animais , Feminino , Deleção de Genes , Peptídeos e Proteínas de Sinalização Intracelular/genética , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Células Piramidais/fisiologia , Córtex Somatossensorial/citologia , Córtex Somatossensorial/fisiologia
10.
Pflugers Arch ; 467(2): 267-84, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24737248

RESUMO

Phospholipase C-related catalytically inactive proteins (PRIP-1/2) are previously reported to be involved in the membrane trafficking of GABAA receptor (GABAAR) and the regulation of intracellular Ca(2+) stores. GABAAR-mediated currents can be regulated by the intracellular Ca(2+). However, in PRIP-1/2 double-knockout (PRIP-DKO) mice, it remains unclear whether the kinetic properties of GABAARs are modulated by the altered regulation of intracellular Ca(2+) stores. Here, we investigated whether GABAAR currents (IGABA) evoked by GABA puff in layer 3 (L3) pyramidal cells (PCs) of the barrel cortex are altered in PRIP-DKO mice. The deletion of PRIP-1/2 enhanced the desensitization of IGABA but induced a hump-like tail current (tail-I) at the GABA puff offset. IGABA and the hump-like tail-I were suppressed by GABAAR antagonists. The enhanced desensitization of IGABA and the hump-like tail-I in PRIP-DKO PCs were mediated by increases in the intracellular Ca(2+) concentration and were largely abolished by a calcineurin inhibitor and ruthenium red. Calcium imaging revealed that Ca(2+)-induced Ca(2+) release (CICR) and subsequent store-operated Ca(2+) entry (SOCE) are more potent in PRIP-DKO PCs than in wild-type PCs. A mathematical model revealed that a slowdown of GABA-unbinding rate and an acceleration of fast desensitization rate by enhancing its GABA concentration dependency are involved in the generation of hump-like tail-Is. These results suggest that in L3 PCs of the barrel cortex in PRIP-DKO mice, the increased calcineurin activity due to the potentiated CICR and SOCE enhances the desensitization of GABAARs and slows the GABA-unbinding rate, resulting in their unusual resensitization following removal of GABA.


Assuntos
Potenciais de Ação , Proteínas Adaptadoras de Transdução de Sinal/metabolismo , Peptídeos e Proteínas de Sinalização Intracelular/metabolismo , Células Piramidais/metabolismo , Receptores de GABA-A/metabolismo , Proteínas Adaptadoras de Transdução de Sinal/química , Proteínas Adaptadoras de Transdução de Sinal/genética , Animais , Sinalização do Cálcio , Domínio Catalítico/genética , Antagonistas de Receptores de GABA-A/farmacologia , Peptídeos e Proteínas de Sinalização Intracelular/química , Peptídeos e Proteínas de Sinalização Intracelular/genética , Camundongos , Camundongos Endogâmicos C57BL , Células Piramidais/efeitos dos fármacos , Células Piramidais/fisiologia
11.
J Prosthodont ; 23(6): 501-3, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27588324

RESUMO

From the mid 1980s (approximately 10 years after titanium was first used as a medical metal), reports of suspected Ti sensitization began to emerge. In the present report,a 33-year-old Japanese woman presented with pruritus of the fingers and a specific reaction to mercury, nickel, and silver on lymphocyte stimulation testing (LST).Her condition improved after 17 restorations containing Hg or Ag were removed.Titanium and composite resin, both of which had no reaction on LST, were used in replacements of the intraoral restoration after the pruritus improved; however, cervical eczema emerged after 9 months, and repeat LST showed a specific reaction to Ti. The eczema improved after removal of the titanium. It is therefore likely that Ti allergy provoked the eczema. This report suggests that clinicians should be aware of the possibility of a titanium allergy from a dental restoration.


Assuntos
Coroas/efeitos adversos , Restauração Dentária Permanente/efeitos adversos , Eczema/induzido quimicamente , Hipersensibilidade/etiologia , Titânio/efeitos adversos , Adulto , Feminino , Humanos
12.
J Prosthodont Res ; 68(2): 283-289, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-37286502

RESUMO

Purpose This study aims to evaluate the effects of resin primers containing methyl methacrylate (MMA) and silane agent on the bonding effectiveness of indirect resin composite blocks with three different filler contents.Methods A commercially available computer-aided design/computer-aided manufacturing (CAD/CAM) resin composite block and two experimental resin composite blocks with different filler contents were alumina-blasted and two surface treatments (primer and silane agent) were applied. The resin cement was built up, and the micro-tensile bond strength (µTBS) was measured after 24 hours, 1 month or 3 months of water storage (n = 24 per group). The fracture surfaces after µTBS measurements and resin block/cement interface were observed by scanning electron microscopy (SEM).Results The primer treatment group showed a significantly higher bond strength than the silane group only in F0 (filler content 0 wt%) group (P < 0.001). In the primer group, F0 and F41 (filler content 41 wt%) groups showed significantly higher bond strengths than F82 (filler content 82 wt%) group (P < 0.001). In contrast, in the silane group, F41 group showed significantly higher bond strength than F0 and F82 groups (P < 0.001), and F82 group showed significantly higher bond strength than F0 group (P < 0.001). SEM revealed that the matrix resin was partially destroyed on the fracture surface of the primer group, and an uneven interface surface was observed compared with that of the silane group.Conclusions MMA-containing primers showed higher bonding effectiveness to CAD/CAM resin composite blocks than the silane treatment.


Assuntos
Colagem Dentária , Silanos , Silanos/química , Propriedades de Superfície , Teste de Materiais , Cimentos de Resina/química , Resinas Compostas/química , Coroas , Resistência à Tração , Desenho Assistido por Computador
13.
J Prosthodont Res ; 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432943

RESUMO

PURPOSE: This study aimed to investigate the effects of the age and sex of tooth donors on dentin bond strength. METHODS: A total of 38 extracted teeth (12 male and 26 female donors; age range: 17-82 years) were used in this study. In addition to donor age and sex, four other microtensile bond strength (µTBS) test specimen factors were evaluated: dentin position, bonding area, presence of voids at the interface, and computed tomography (CT) values of dentin. The µTBS was measured immediately (24 h) and 6 months after storage in water. After the µTBS testing, linear mixed and nonlinear regression models were used to analyze the effects of these factors on the µTBS data. RESULTS: The results from the linear mixed model revealed that the bonding area (P = 0.02), presence of voids at the interface (P = 0.04), and storage time (P < 0.001) significantly affected bond strength. In contrast, no correlation was observed between the µ TBS and dentin position (P = 0.08) or sex (P = 0.07). The results of the nonlinear regression model with robust variance-covariance estimators revealed that age significantly affected bond strength (P < 0.001). In addition, a significant positive correlation was found between µTBS and age (P < 0.001), with nonlinearity (P = 0.002). However, no correlation was observed between the µTBS and CT values (P = 0.69) without nonlinearity (P = 0.39). CONCLUSIONS: These findings suggest that bond strength increases with age until 60 years but not afterward.

14.
Clin Oral Implants Res ; 24(10): 1117-22, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22712431

RESUMO

OBJECTIVES: The aim of this study was to devise an optical impression method that could make impressions of dental implants accurately and rapidly. MATERIALS AND METHODS: Four paper markers (4 × 3 mm, 8 × 6 mm, 16 × 12 mm, and 24 × 18 mm) and one titanium marker (8 × 6 mm) were prepared to determine the measuring accuracy of the three-dimensional optical tracker. For a proposed and conventional impression taking method, we compared the reproduction accuracies of the positions and orientations of dental implants and the times to obtain impressions. Finally, we fabricated computer-aided designing (CAD)/computer-aided manufacturing (CAM) superstructure frameworks to determine the adaptation accuracy. RESULTS: The 8 × 6-mm titanium marker was optimal among the prepared markers. Dental implants made by the proposed and conventional impression taking methods had measurement errors of 71 ± 31 µm and 32 ± 18 µm, respectively. The proposed method took a significantly shorter time to obtain an impression than did the conventional method. The connection between the CAD/CAM superstructure frameworks and four implant analogs had uplifts of 55 ± 10 µm, 94 ± 35 µm, 2 ± 1 µm, and 66 ± 3 µm. CONCLUSION: Our proposed method and fabricated titanium markers enabled us to measure the positions and orientations of dental implants both accurately and rapidly. We then used the reproducible measurement results for the positions and orientations of the dental implants to fabricate CAD/CAM superstructure frameworks within an acceptable accuracy range.


Assuntos
Implantes Dentários , Planejamento de Prótese Dentária/instrumentação , Imagem Óptica , Algoritmos , Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Humanos , Imageamento Tridimensional , Reprodutibilidade dos Testes , Fatores de Tempo , Titânio
15.
J Prosthodont Res ; 67(1): 77-86, 2023 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-35185110

RESUMO

Purpose The involvement of oral mucosa cells in mechanical stress-induced bone resorption is unclear. The aim of this study was to investigate the effects of cyclic pressure-induced cytokines from oral mucosal cells (human gingival fibroblasts: hGFs) on osteoclast activity in vitro.Methods Cyclic pressure at 50 kPa, which represents high physiologic occlusal force of dentures on the molar area, was applied to hGFs. NFAT-reporter stable RAW264.7 preosteoclasts (NFAT/Luc-RAW cells) were cultured in conditioned medium collected from hGF cultures under cyclic pressure or static conditions. NFAT activity and osteoclast formation were determined by luciferase reporter assay and TRAP staining, respectively. Cyclic pressure-induced cytokines in hGF culture were detected by ELISA, real-time RT-PCR, and cytokine array analyses.Results Conditioned media from hGFs treated with 48 hours of cyclic pressure significantly induced NFAT activity and increased multinucleated osteoclast formation. Furthermore, the cyclic pressure significantly increased the bone resorption activity of RAW264.7 cells. Cyclic pressure significantly increased the expression of major inflammatory cytokines including IL-1ß/IL-1ß, IL-6/IL-6, IL-8/IL-8 and MCP-1/CCL2 in hGFs compared to hGFs cultured under static conditions, and it suppressed osteoprotegerin (OPG/OPG) expression. A cytokine array detected 12 cyclic pressure-induced candidates. Among them, IL-8, decorin, MCP-1 and ferritin increased, whereas IL-28A and PDGF-BB decreased, NFAT activation of NFAT/Luc-RAW cells.Conclusions These results suggest that cyclic pressure-induced cytokines from hGFs promote osteoclastogenesis, possibly including up-regulation of IL-1ß, IL-6, IL-8 and MCP-1, and down-regulation of OPG. These findings introduce the possible involvement of GFs in mechanical stress-induced alveolar ridge resorption, such as in denture wearers.


Assuntos
Perda do Osso Alveolar , Citocinas , Humanos , Citocinas/metabolismo , Citocinas/farmacologia , Osteoclastos/metabolismo , Interleucina-6/metabolismo , Interleucina-6/farmacologia , Perda do Osso Alveolar/metabolismo , Interleucina-8/metabolismo , Interleucina-8/farmacologia , Células Cultivadas , Fibroblastos/metabolismo , Dentaduras , Ligante RANK/metabolismo , Ligante RANK/farmacologia , Diferenciação Celular
16.
J Prosthodont Res ; 67(3): 392-399, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-36288977

RESUMO

PURPOSE: This observational study aimed to elucidate the pathophysiology of subchondral cysts (SC) in the temporomandibular joint (TMJ) and examine the results of conservative therapy administered to patients with SCs in the TMJ. METHODS: The study included 41 patients with SCs, extracted from 684 consecutive patients who underwent magnetic resonance imaging (MRI). The anatomical features of SCs and positional abnormalities of the articular disc were initially evaluated using MRI. A second MRI examination was performed for 28/41 patients at 40-107 months (mean, 66 months) after the first MRI. The joint space, anteroposterior width of the condylar head (WiC), articular eminence angle (AEA), and visual analog scale of jaw pain (VAS) were assessed alongside the MRI examinations. RESULTS: Most SCs were present in the anterosuperior and central condyle. Disc displacement was observed in 100% of 42 TMJs with SCs. Of the 29 joints in 28 patients, SCs in 19 joints resolved with time, whereas SCs in 10 joints persisted. A significant increase in the WiC and a significant decrease in AEA and VAS scores were observed on the second MRI scan. CONCLUSIONS: SCs tended to form in the anterosuperior and central parts of the condyle, where mechanical loading was likely to be applied. SCs are strongly associated with articular disc displacement. Two-thirds of SCs resolved over time, accompanied by resorption and osteophytic deformation of the condyle. SC might not be an indicator for the start of surgical treatment, and nonsurgical treatment could improve the clinical symptoms of patients with SCs.


Assuntos
Cistos Ósseos , Luxações Articulares , Transtornos da Articulação Temporomandibular , Humanos , Seguimentos , Estudos Transversais , Côndilo Mandibular/diagnóstico por imagem , Côndilo Mandibular/patologia , Transtornos da Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/terapia , Articulação Temporomandibular/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Cistos Ósseos/diagnóstico por imagem , Cistos Ósseos/patologia , Luxações Articulares/patologia , Luxações Articulares/terapia
17.
J Prosthodont Res ; 67(2): 189-195, 2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35644569

RESUMO

PURPOSE: To investigate the effect of prosthodontic treatment on the ingestible food profile in adult Japanese outpatients, and to identify the related risk factors that can deteriorate the profile. METHODS: The participants were 277 outpatients who visited university-based specialty clinics in Japan for prosthodontic treatment. The demographic data, number of present teeth assessed via intraoral examination, and oral health-related quality of life assessed by the total Oral Health Impact Profile (OHIP-J54) scores of all participants were recorded before treatment. Ingestible food profile score (IFS) was recorded using a validated food intake questionnaire. Eligible participants who answered the questionnaire before and after treatment were categorized into five groups based on the prosthodontic treatments they received (i.e., crowns, bridges, removable partial dentures, removable complete dentures, and removable complete and partial dentures). RESULTS: Multivariate analysis of covariance revealed a statistically significant main effect of prosthodontic intervention (time course: before and after treatment) on mean IFS (P=0.035, F=4.526), even after adjusting for covariates (age, number of present teeth, and treatment modality). Multiple linear regression analysis revealed that the low number of present teeth (r=0.427, P<0.001) and a high OHIP-J54 total score (r=-0.519, P<0.001) of the patients at the baseline were significantly associated with their baseline IFSs, even after adjusting for confounding variables. CONCLUSIONS: The findings of this multicenter follow-up study indicate the importance of prosthodontic rehabilitation in improving patients' ingestible food profiles.


Assuntos
Prótese Parcial Removível , Qualidade de Vida , Adulto , Humanos , População do Leste Asiático , Seguimentos , Saúde Bucal , Pacientes Ambulatoriais , Prostodontia , Alimentos , Dieta
18.
Sci Rep ; 12(1): 12915, 2022 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-35902714

RESUMO

Temporal summation of second pain (TSSP) has been suggested as a psychophysical index for central sensitization, one of the critical mechanisms in the chronification of pain. However, there is no gold standard for protocols to measure TSSP. The purpose was to establish the stimulus intensity for measuring TSSP. Female patients with chronic myofascial temporomandibular disorders pain (n = 16) and healthy female volunteers with no pain (n = 15) participated. Pain thresholds (PT °C) were measured, and repetitive heat stimuli at three stimulus intensities (PT °C, PT + 1 °C, PT + 2 °C) were applied. TSSP parameters were quantified as TSSP magnitude (TSm) and TSSP frequency (TSf). In healthy female volunteers, pain ratings significantly decreased at PT °C (p < 0.050), besides TSm and TSf at PT + 2 °C were significantly higher than those at PT °C (p < 0.025). In chronic pain patients, pain ratings significantly increased at PT + 1 °C and PT + 2 °C (p < 0.050). At PT + 2 °C, TSm and TSf in chronic pain patients were significantly higher than those in healthy volunteers (p < 0.050). It could be helpful to measure TSSP with the stimulus intensity adjusted individually to the patient's pain thresholds + 2 °C for assessing central sensitization.


Assuntos
Dor Crônica , Medição da Dor , Limiar da Dor , Dor Crônica/diagnóstico , Feminino , Temperatura Alta , Humanos , Dor/etiologia , Medição da Dor/métodos , Somação de Potenciais Pós-Sinápticos
19.
Biomedicines ; 10(2)2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35203635

RESUMO

Small-molecule compounds strongly affecting osteogenesis can form the basis of effective therapeutic strategies in bone regenerative medicine. A cell-based high-throughput screening system might be a powerful tool for identifying osteoblast-targeting candidates; however, this approach is generally limited with using only one molecule as a cell-based sensor that does not always reflect the activation of the osteogenic phenotype. In the present study, we used the MC3T3-E1 cell line stably transfected with the green fluorescent protein (GFP) reporter gene driven by a fragment of type I collagen promoter (Col-1a1GFP-MC3T3-E1) to evaluate a double-screening system to identify osteogenic inducible compounds using a combination of a cell-based reporter assay and detection of alkaline phosphatase (ALP) activity. Col-1a1GFP-MC3T3-E1 cells were cultured in an osteogenic induction medium after library screening of 1280 pharmacologically active compounds (Lopack1280). After 7 days, GFP fluorescence was measured using a microplate reader. After 14 days of osteogenic induction, the cells were stained with ALP. Library screening using the Col-1a1/GFP reporter and ALP staining assay detected three candidates with significant osteogenic induction ability. Furthermore, leflunomide, one of the three detected candidates, significantly promoted new bone formation in vivo. Therefore, this double-screening method could identify candidates for osteogenesis-targeting compounds more reliably than conventional methods.

20.
Dent Mater J ; 41(2): 317-322, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34980768

RESUMO

A two-bottle self-curing universal adhesive (Tokuyama Universal Bond; Tokuyama Dental) that does not require a long waiting time or light curing after application of the bonding material has been developed. This study aimed to evaluate the influence of tooth and adhesive temperature during the bonding procedure on the effectiveness of dentin bonding. The results showed that the tooth temperature affected the effectiveness of the dentin bonding; therefore, to determine the precise bonding ability in the laboratory, the temperature of the tooth must be raised until it is the same as that of the oral cavity. In addition, the temperature of the material did not affect bonding effectiveness; this result confirms that it does not matter whether the refrigerated product is used soon after its removal from the refrigerator or after it reaches room temperature in the clinic.


Assuntos
Colagem Dentária , Adesivos Dentinários , Adesivos/química , Colagem Dentária/métodos , Cimentos Dentários , Dentina , Adesivos Dentinários/química , Teste de Materiais/métodos , Cimentos de Resina/química , Temperatura , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA