Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Platelets ; 31(3): 373-382, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31311384

RESUMO

Platelets are central to thrombosis. However, it is unknown whether platelets slip at vascular or device surfaces. The presence of platelet slip at a surface would interrupt physical contact between the platelet and that surface, and therefore diminish adhesion and thrombosis. Unfortunately, no existing technology can directly measure platelet slip in a biological environment. The objective of this study was to explore whether microspheres-modeling platelets-slip at different vascular and device surfaces in an acrylic scaled-up model coronary artery. The microspheres (3.12 µm diameter) were suspended in a transparent glycerol/water experimental fluid, which flowed continuously at Reynolds numbers typical of coronary flow (200-400) through the model artery. We placed a series of axisymmetric acrylic stenoses (cross-sectional area reduction [CSAr], 20-90%) into the model artery, both without and with a central cylinder present (modeling a percutaneous interventional guide wire, and with a scaled-up Doppler catheter mounted upstream). We used laser Doppler velocimetry (LDV) to measure microsphere velocities within, proximal and distal to each stenosis, and compared to computer simulations of fluid flow with no-slip. For validation, we replaced the acrylic with paraffin stenoses (more biologically relevant from a surface roughness perspective) and then analyzed the signal recorded by the scaled-up Doppler catheter. Using the LDV, we identified progressive microsphere slip proportional to CSAr inside entrances for stenoses ≥60% and ≥40% without and with cylinder present, respectively. Additionally, microsphere slip occurred universally along the cylinder surface. Computer simulations indicated increased fluid shear rates (velocity gradients) at these particular locations, and logistic regression analysis comparing microsphere slip with fluid shear rate resulted in a c-index of 0.989 at a cut-point fluid shear rate of (10.61 [cm-1]×mean velocity [cm×sec-1]). Moreover, the presence of the cylinder caused disordering of microsphere shear rates distal to higher grade stenoses, indicating a disturbance in their flow. Finally, despite lower precision, the signal recorded by the scaled-up Doppler catheter nonetheless indicated slip at the entry into and at most locations distal to the 90% stenosis. Our validated model establishes proof of concept for platelet slip, and platelet slip explains several important basic and clinical observations. If technological advances allow confirmation in a true biologic environment, then our results will likely influence the development of shear-dependent antiplatelet drugs. Also, adding shear rate information, our results provide a direct experimental fluid dynamic foundation for antiplatelet-focused antithrombotic therapy during coronary interventions directed towards higher grade atherosclerotic stenoses.


Assuntos
Plaquetas/metabolismo , Constrição Patológica/metabolismo , Trombose/etiologia , Trombose/metabolismo , Velocidade do Fluxo Sanguíneo , Plaquetas/imunologia , Constrição Patológica/diagnóstico , Humanos , Microscopia , Modelos Biológicos , Trombose/patologia , Ultrassonografia Doppler
2.
Catheter Cardiovasc Interv ; 91(5): 874-883, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28707349

RESUMO

BACKGROUND: In vivo assessment of bioresorbable scaffold (BRS) is of growing clinical interest. The novel 60MHz high-definition intravascular ultrasound (HD-IVUS) has been developed to overcome the limitations of conventional 40 MHz IVUS. This study aimed to evaluate the performance and limitations of 60 MHz HD-IVUS compared with 40 MHz IVUS with respect to polymeric-strut visualization, quantitative and qualitative analysis, and feasibility of high-speed pullback in the assessment of BRS. METHODS AND RESULTS: In a bench-test model, 361 struts were analyzed to evaluate the influence of ultrasound-beam angles and proximity of adjacent struts on IVUS visualization of BRS struts. Various settings were created by deforming the BRS and positioning the transducer offcenter. In an in vivo swine coronary model, scaffold and lumen areas, degree of visible external elastic membrane, incomplete strut apposition, and strut fracture were evaluated in 59 matched cross-sections obtained at conventional (0.5 mm/sec) and high speed (10 mm/sec) pullbacks. Both studies utilized optical coherence tomography (OCT) as reference. Overall, 60 MHz HD-IVUS demonstrated significantly improved visualization of polymeric struts compared with 40 MHz IVUS (well-visualized: 84.5% vs 62.3%, not visible: 4.4% vs 13.9%, respectively. P < 0.001), which was less affected by the beam angle and adjacent strut proximity. In the in vivo model, 60-MHz HD-IVUS showed better agreement of area measurements and strut abnormalities with OCT than 40 MHz IVUS. These findings were also confirmed on high-speed pullback images of 60 MHz HD-IVUS. CONCLUSION: As referenced to OCT, this study showed superiority of 60 MHz HD-IVUS over 40 MHz IVUS in the assessment of BRS with feasibility of high-speed pullback imaging.


Assuntos
Implantes Absorvíveis , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Intervenção Coronária Percutânea/instrumentação , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Animais , Estudos de Viabilidade , Feminino , Teste de Materiais , Modelos Anatômicos , Modelos Animais , Valor Preditivo dos Testes , Desenho de Prótese , Sus scrofa
3.
Radiology ; 280(3): 826-36, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27332865

RESUMO

Purpose To quantitatively determine the limit of detection of marrow stromal cells (MSC) after cardiac cell therapy (CCT) in swine by using clinical positron emission tomography (PET) reporter gene imaging and magnetic resonance (MR) imaging with cell prelabeling. Materials and Methods Animal studies were approved by the institutional administrative panel on laboratory animal care. Seven swine received 23 intracardiac cell injections that contained control MSC and cell mixtures of MSC expressing a multimodality triple fusion (TF) reporter gene (MSC-TF) and bearing superparamagnetic iron oxide nanoparticles (NP) (MSC-TF-NP) or NP alone. Clinical MR imaging and PET reporter gene molecular imaging were performed after intravenous injection of the radiotracer fluorine 18-radiolabeled 9-[4-fluoro-3-(hydroxyl methyl) butyl] guanine ((18)F-FHBG). Linear regression analysis of both MR imaging and PET data and nonlinear regression analysis of PET data were performed, accounting for multiple injections per animal. Results MR imaging showed a positive correlation between MSC-TF-NP cell number and dephasing (dark) signal (R(2) = 0.72, P = .0001) and a lower detection limit of at least approximately 1.5 × 10(7) cells. PET reporter gene imaging demonstrated a significant positive correlation between MSC-TF and target-to-background ratio with the linear model (R(2) = 0.88, P = .0001, root mean square error = 0.523) and the nonlinear model (R(2) = 0.99, P = .0001, root mean square error = 0.273) and a lower detection limit of 2.5 × 10(8) cells. Conclusion The authors quantitatively determined the limit of detection of MSC after CCT in swine by using clinical PET reporter gene imaging and clinical MR imaging with cell prelabeling. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Genes Reporter , Coração/diagnóstico por imagem , Transplante de Células-Tronco Mesenquimais , Imagem Molecular/métodos , Imagem Multimodal/métodos , Animais , Radioisótopos de Flúor , Guanina/análogos & derivados , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Suínos
4.
Radiology ; 280(3): 815-25, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27308957

RESUMO

Purpose To use multimodality reporter-gene imaging to assess the serial survival of marrow stromal cells (MSC) after therapy for myocardial infarction (MI) and to determine if the requisite preclinical imaging end point was met prior to a follow-up large-animal MSC imaging study. Materials and Methods Animal studies were approved by the Institutional Administrative Panel on Laboratory Animal Care. Mice (n = 19) that had experienced MI were injected with bone marrow-derived MSC that expressed a multimodality triple fusion (TF) reporter gene. The TF reporter gene (fluc2-egfp-sr39ttk) consisted of a human promoter, ubiquitin, driving firefly luciferase 2 (fluc2), enhanced green fluorescent protein (egfp), and the sr39tk positron emission tomography reporter gene. Serial bioluminescence imaging of MSC-TF and ex vivo luciferase assays were performed. Correlations were analyzed with the Pearson product-moment correlation, and serial imaging results were analyzed with a mixed-effects regression model. Results Analysis of the MSC-TF after cardiac cell therapy showed significantly lower signal on days 8 and 14 than on day 2 (P = .011 and P = .001, respectively). MSC-TF with MI demonstrated significantly higher signal than MSC-TF without MI at days 4, 8, and 14 (P = .016). Ex vivo luciferase activity assay confirmed the presence of MSC-TF on days 8 and 14 after MI. Conclusion Multimodality reporter-gene imaging was successfully used to assess serial MSC survival after therapy for MI, and it was determined that the requisite preclinical imaging end point, 14 days of MSC survival, was met prior to a follow-up large-animal MSC study. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Genes Reporter , Transplante de Células-Tronco Mesenquimais/métodos , Imagem Molecular , Imagem Multimodal , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/terapia , Animais , Feminino , Luciferases de Vaga-Lume/metabolismo , Medições Luminescentes , Camundongos , Camundongos Nus , Tomografia por Emissão de Pósitrons , Transfecção
5.
Catheter Cardiovasc Interv ; 83(1): 19-24, 2014 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23413202

RESUMO

OBJECTIVES: The aim of this study was to evaluate the Sparrow sirolimus-eluting stent (Sparrow-SES) against the Sparrow bare-metal stent (Sparrow-BMS) and conventional balloon-expandable bare-metal stent (BMS: Driver/Micro-Driver stent, Medtronic Vascular, Santa Rosa, CA). BACKGROUND: The Sparrow stent (Biosensors International, Singapore) consists of a guide wire-based, self-expandable, ultra-thin nitinol stent. The performance of this device with sirolimus in a fully biodegradable polymer has not been determined. METHODS: A total of 74 patients were included in this intravascular ultrasound (IVUS) sub-study of the CARE II trial, which was a prospective, randomized, multicenter trial in the treatment of single de novo native coronary artery lesions in vessels ranging from 2.0 mm to 2.75 mm in diameter (Sparrow-SES: n = 31, Sparrow-BMS: n = 22, BMS: n = 21). RESULTS: Stent volume index (VI) was significantly increased 8-month later in Sparrow-SES and Sparrow-BMS, but not in BMS (4.0 ± 1.0 to 4.6 ± 1.0 mm(3) /mm, p<0.0001, 4.0 ± 0.6 to 4.4 ± 0.8 mm(3) /mm, p<0.05, and 5.2 ± 1.0 to 5.1 ± 0.9 mm(3) /mm, p=0.421, respectively). % neointimal obstruction in Sparrow-SES was significantly smaller than those in Sparrow-BMS and BMS at follow-up (17.6 ± 9.4 vs. 36.2 ± 13.8 and 39.9 ± 11.1%, p<0.001). Sparrow-SES showed a mean 15% stent expansion and good suppression of neointimal proliferation, resulting in a significantly lower percentage of change in lumen VI during follow-up period (Sparrow-SES: -6.2 ± 16.2%, Sparrow-BMS: -30.4 ± 11.6%, BMS: -40.4 ± 10.0%, p<0.001). CONCLUSIONS: The self-expanding Sparrow-SES demonstrated chronic stent expansion, good suppression of neointimal proliferation and resulted in a more preserved lumen in stented small vessels compared with the Sparrow-BMS and conventional balloon expandable BMS.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Sirolimo/administração & dosagem , Stents , Ultrassonografia de Intervenção , Idoso , Ligas , Angioplastia Coronária com Balão/efeitos adversos , Proliferação de Células , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 81(3): E173-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21805600

RESUMO

OBJECTIVES: The aim of this study was to evaluate a new fully automated lumen border tracing system based on a novel multifrequency processing algorithm. BACKGROUND: We developed the multifrequency processing method to enhance arterial lumen detection by exploiting the differential scattering characteristics of blood and arterial tissue. The implementation of the method can be integrated into current intravascular ultrasound (IVUS) hardware. METHODS: This study was performed in vivo with conventional 40-MHz IVUS catheters (Atlantis SR Pro™, Boston Scientific Corp, Natick, MA) in 43 clinical patients with coronary artery disease. A total of 522 frames were randomly selected, and lumen areas were measured after automatically tracing lumen borders with the new tracing system and a commercially available tracing system (TraceAssist™) referred to as the "conventional tracing system." The data assessed by the two automated systems were compared with the results of manual tracings by experienced IVUS analysts. RESULTS: New automated lumen measurements showed better agreement with manual lumen area tracings compared with those of the conventional tracing system (correlation coefficient: 0.819 vs. 0.509). When compared against manual tracings, the new algorithm also demonstrated improved systematic error (mean difference: 0.13 vs. -1.02 mm(2) ) and random variability (standard deviation of difference: 2.21 vs. 4.02 mm(2) ) compared with the conventional tracing system. CONCLUSIONS: This preliminary study showed that the novel fully automated tracing system based on the multifrequency processing algorithm can provide more accurate lumen border detection than current automated tracing systems and thus, offer a more reliable quantitative evaluation of lumen geometry.


Assuntos
Algoritmos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Ultrassonografia de Intervenção/instrumentação , Desenho de Equipamento , Humanos , Reprodutibilidade dos Testes
7.
Int J Cardiol ; 379: 24-32, 2023 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-36893856

RESUMO

OBJECTIVES: This study aimed to explore the impact of myocardial bridging (MB) on early development of cardiac allograft vasculopathy and long-term graft survival after heart transplantation. BACKGROUND: MB has been reported to be associated with acceleration of proximal plaque development and endothelial dysfunction in native coronary atherosclerosis. However, its clinical significance in heart transplantation remains unclear. METHODS: In 103 heart-transplant recipients, serial (baseline and 1-year post-transplant) volumetric intravascular ultrasound (IVUS) analyses were performed in the first 50 mm of the left anterior descending (LAD) artery. Standard IVUS indices were evaluated in 3 equally divided LAD segments (proximal, middle, and distal segments). MB was defined by IVUS as an echolucent muscular band lying on top of the artery. The primary endpoint was death or re-transplantation, assessed for up to 12.2 years (median follow-up: 4.7 years). RESULTS: IVUS identified MB in 62% of the study population. At baseline, MB patients had smaller intimal volume in the distal LAD than non-MB patients (p = 0.002). During the first year, vessel volume decreased diffusely irrespective of the presence of MB. Intimal growth diffusely distributed in non-MB patients, whereas MB patients demonstrated significantly augmented intimal formation in the proximal LAD. Kaplan-Meier analysis revealed significantly lower event-free survival in patients with versus without MB (log-rank p = 0.02). In multivariate analysis, the presence of MB was independently associated with late adverse events [hazard ratio 5.1 (1.6-22.2)]. CONCLUSION: MB appears to relate to accelerated proximal intimal growth and reduced long-term survival in heart-transplant recipients.


Assuntos
Doença da Artéria Coronariana , Transplante de Coração , Ponte Miocárdica , Humanos , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Ultrassonografia de Intervenção , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Transplante de Coração/efeitos adversos
8.
J Vasc Interv Radiol ; 23(4): 488-94, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22464713

RESUMO

PURPOSE: To determine the feasibility and efficacy of applying an established innovation process to an active academic interventional radiology (IR) practice. MATERIALS AND METHODS: The Stanford Biodesign Medical Technology Innovation Process was used as the innovation template. Over a 4-month period, seven IR faculty and four IR fellow physicians recorded observations. These observations were converted into need statements. One particular need relating to gastrostomy tubes was diligently screened and was the subject of a single formal brainstorming session. RESULTS: Investigators collected 82 observations, 34 by faculty and 48 by fellows. The categories that generated the most observations were enteral feeding (n = 9, 11%), biopsy (n = 8, 10%), chest tubes (n = 6, 7%), chemoembolization and radioembolization (n = 6, 7%), and biliary interventions (n = 5, 6%). The output from the screening on the gastrostomy tube need was a specification sheet that served as a guidance document for the subsequent brainstorming session. The brainstorming session produced 10 concepts under three separate categories. CONCLUSIONS: This formalized innovation process generated numerous observations and ultimately 10 concepts to potentially to solve a significant clinical need, suggesting that a structured process can help guide an IR practice interested in medical innovation.


Assuntos
Avaliação das Necessidades/organização & administração , Inovação Organizacional , Radiologia Intervencionista/métodos , Radiologia Intervencionista/tendências , California
9.
Int J Cardiol Heart Vasc ; 36: 100867, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34504947

RESUMO

INTRODUCTION: The present study aimed to compare the accuracy of quantitative measurements by contemporary intravascular imaging systems including optical frequency domain imaging (OFDI), frequency domain optical coherence tomography (FD-OCT), and 6 intravascular ultrasound (IVUS) systems. METHODS: We imaged five cylindrical phantom models made from an acrylic resin with known lumen diameters (1.51, 2.03, 3.04, 4.04, and 5.04 mm, respectively) using OFDI (FastView and LUNAWAVE, Terumo), FD-OCT (Dragonfly JP and ILUMIEN OPTIS, Abbott Vascular), and 6 mechanically rotating IVUS systems including a system, two 40-MHz, one 45-MHz, two 60-Mhz and one broad-band frequency IVUS systems. The OFDI, FD-OCT, and IVUS images were obtained using automated motorized pullback in a tank filled with 37-degree Celsius saline and, in cases of OFDI and FD-OCT, contrast-saline mixture (1:1 ratio) and contrast under the system setting of the refractive index for the corresponding flush medium. RESULTS: All the imaging systems showed good accuracy and excellent precision of lumen measurement with the relative differences between the measured diameter and actual phantom diameter being ranging from -2.9% to 8.0% and minimum standard deviations of the measured diameters (≤0.02 mm). CONCLUSION: The present study demonstrated that contemporary intravascular imaging systems including OFDI, FD-OCT, and IVUS provided clinically acceptable accuracy and excellent precision of quantitative lumen measurement in phantom models in vitro across a wide range of dimensions. Future research to confirm these findings in vivo are warranted.

10.
Int J Cardiol ; 333: 55-59, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-33741429

RESUMO

BACKGROUND: Accurate segmentation of the coronary arteries with intravascular ultrasound (IVUS) is important to optimize coronary stent implantation. Recently, deep learning (DL) methods have been proposed to develop automatic IVUS segmentation. However, most of those have been limited to segmenting the lumen and vessel (i.e. lumen-intima and media-adventitia borders), not applied to segmenting stent dimension. Hence, this study aimed to develop a DL method for automatic IVUS segmentation of stent area in addition to lumen and vessel area. METHODS: This study included a total of 45,449 images from 1576 IVUS pullback runs. The datasets were randomly split into training, validation, and test datasets (0.7:0.15:0.15). After developing the DL-based system to segment IVUS images using the training and validation datasets, we evaluated the performance through the independent test dataset. RESULTS: The DL-based segmentation correlated well with the expert-analyzed segmentation with a mean intersection over union (± standard deviation) of 0.80 ± 0.20, correlation coefficient of 0.98 (95% confidence intervals: 0.98 to 0.98), 0.96 (0.95 to 0.96), and 0.96 (0.96 to 0.96) for lumen, vessel, and stent area, and the mean difference (± standard deviation) of 0.02 ± 0.57, -0.44 ± 1.56 and - 0.17 ± 0.74 mm2 for lumen, vessel and stent area, respectively. CONCLUSION: This automated DL-based IVUS segmentation of lumen, vessel and stent area showed an excellent agreement with manual segmentation by experts, supporting the feasibility of artificial intelligence-assisted IVUS assessment in patients undergoing coronary stent implantation.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Algoritmos , Inteligência Artificial , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Ultrassonografia de Intervenção
12.
J Cardiol ; 78(3): 224-229, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33893022

RESUMO

BACKGROUND: The long-term prognostic impact of IVUS findings following Absorb BVS implantation remains uncertain. This study aimed to identify the IVUS predictors of long-term clinical outcomes following ABSORB bioresorbable vascular scaffold (BVS) implantation from the pooled IVUS substudy cohorts of the ABSORB III and Japan trials. METHODS: A total of 298 lesions in 286 patients were enrolled with 2:1 randomization to ABSORB BVS vs. cobalt-chromium everolimus-eluting stents. This sub-analysis included 168 lesions of 160 patients in the Absorb arm whose post-procedural quantitative IVUS were available. The primary endpoint of this analysis was device-oriented composite endpoint (DOCE) of target lesion failure, including cardiac death, target vessel-related myocardial infarction, or ischemia-driven target lesion revascularization. The median follow-up duration was 4.9 [3.1-5.0] years. RESULTS: During follow-up, DOCE occurred in 10.1% of lesions treated with Absorb BVS. Among several post-procedural IVUS indices associated with DOCE, non-uniform device expansion (defined as uniformity index = minimum / maximum device area) (hazard ratio 0.47 per 0.1 increase [95%CI 0.28 to 0.77]; p = 0.003) and residual reference plaque burden (hazard ratio 4.01 per 10% increase [95%CI 1.50 to 10.77]; p = 0.006) were identified as independent predictors of DOCE by Cox multivariable analysis. CONCLUSIONS: Nonuniform device expansion and substantial untreated residual plaque in reference segments were associated with long-term adverse events following BVS implantation. Baseline imaging to identify the appropriate device landing zone and procedural imaging to achieve uniform device expansion if possible (e.g. through post-dilatation) may improve clinical outcomes of BVS implantation. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01751906 (ABSORB III); NCT01844284 (ABSORB Japan).


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Japão , Desenho de Prótese , Resultado do Tratamento , Ultrassonografia de Intervenção
13.
Int J Cardiol Heart Vasc ; 31: 100623, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32944608

RESUMO

BACKGROUND: Device underexpansion is associated with late adverse outcomes after bioresorbable vascular scaffold (BVS) implantation. This study, representing official IVUS results of the ABSORB Japan trial, aimed to characterize IVUS findings, focusing specifically on acute device expansion, and to investigate its impact on late lumen loss (LLL) with Absorb-BVS compared with cobalt-chromium everolimus-eluting stents (CoCr-EES). METHODS: ABSORB Japan enrolled 148 patients (2:1 randomization) in the IVUS cohort. Serial IVUS was prescheduled at post-procedure and 3 years. Acute device expansion was evaluated with respect to the degree and uniformity of the implanted device. RESULTS: Overall, Absorb-BVS showed smaller and more nonuniform device expansion at post-procedure, compared with CoCr-EES, which was particularly prominent in small-vessel lesions. In serial analysis, Absorb-BVS showed unique associations of smaller device expansion (r = 0.40, p = 0.001) and more nonuniformity (r = 0.29, p = 0.007) at post-procedure with greater LLL at 3 years, primarily attributable to greater negative remodeling (r = 0.39, p = 0.006). In contrast, acute device expansion showed no relation with subsequent lumen change in CoCr-EES. In Absorb-BVS, ischemic-driven target lesion or vessel revascularization (ID-TLR or ID-TVR) at 3 years occurred more frequently in small- versus large-vessel lesions (12.5% vs. 0%, p = 0.04 for ID-TLR and 15.6% vs. 2.3%, p = 0.08 for ID-TVR). Conversely, Absorb BVS had no target lesion nor vessel failure, even in small-vessel lesions, when adequate device expansion was achieved at post-procedure. CONCLUSIONS: Unlike CoCr-EES, underexpansion was associated with greater negative remodeling and LLL in Absorb-BVS. This may in part account for the poorer outcomes of Absorb-BVS than CoCr-EES when under-expanded.

15.
Int J Cardiol ; 290: 27-32, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30987835

RESUMO

BACKGROUND: Acute allograft rejection (AAR) plays an important role in patient and graft survival; therefore, more emphasis should be placed on its prediction. This study aimed to investigate baseline clinical and diagnostic variables associated with subsequent AAR during the first year post-transplant, especially focusing on early physiologic and anatomic measures. METHODS: This study enrolled 88 heart transplant patients who underwent fractional flow reserve (FFR), coronary flow reserve (CFR), the index of microcirculatory resistance (IMR) and intravascular ultrasound (IVUS) in the left anterior descending artery at baseline (within 8 weeks post-transplant). Cardiac index (CI), pulmonary capillary wedge pressure (PCWP), mean pulmonary artery pressure (mPAP), right atrial pressure and left ventricular ejection fraction were also evaluated. AAR was defined as acute cellular rejection of grade ≥2R and/or pathological antibody-mediated rejection of grade ≥pAMR2. RESULTS: During the first year post-transplant, 25.0% of patients experienced AAR. Patients with AAR during the first year showed higher rates of recipient obesity, lower rates of recipient-donor sex mismatch and rATG and tacrolimus uses, higher PCWP, mPAP and IMR, and lower CFR at baseline, compared with those without. In the multivariate analysis, only baseline IMR ≥ 16.0 was independently associated with AAR during the first year, demonstrating high negative predictive value (96.7%). CONCLUSIONS: Invasively assessing microvascular resistance (baseline IMR ≥ 16.0) in the early post-transplant period was an independent determinant of subsequent acute allograft rejection during the first year post-transplant, suggesting that early assessment of IMR may enhance patient risk stratification and target medical therapies to improve patient outcome.


Assuntos
Angiografia Coronária/métodos , Circulação Coronária/fisiologia , Rejeição de Enxerto/diagnóstico por imagem , Transplante de Coração/tendências , Microcirculação/fisiologia , Adulto , Idoso , Diagnóstico Precoce , Feminino , Seguimentos , Rejeição de Enxerto/tratamento farmacológico , Rejeição de Enxerto/fisiopatologia , Humanos , Imunossupressores/uso terapêutico , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Estudos Retrospectivos , Volume Sistólico/fisiologia
16.
JACC Cardiovasc Interv ; 11(7): 648-661, 2018 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-29622143

RESUMO

OBJECTIVES: The aim of this study was to characterize post-procedural intravascular ultrasound (IVUS) findings in the ABSORB Japan trial, specifically stratified by the size of target coronary arteries. BACKGROUND: Despite overall noninferiority confirmed in recent randomized trials comparing bioresorbable vascular scaffolds (BVS) (Absorb BVS) and cobalt-chromium everolimus-eluting metallic stents (CoCr-EES), higher event rates of Absorb BVS have been reported with suboptimal deployment, especially in small coronary arteries. METHODS: In the ABSORB Japan trial, 150 patients (2:1 randomization) were scheduled in the IVUS cohort. Small vessel was defined as mean reference lumen diameter <2.75 mm. Tapered-vessel lesions were defined as tapering index (proximal/distal reference lumen diameter) ≥1.2. RESULTS: Overall, IVUS revealed that the Absorb BVS arm had smaller device expansion than the CoCr-EES arm did, which was particularly prominent in small- and tapered-vessel lesions. Higher tapering index was also associated with higher rates of incomplete strut apposition in Absorb BVS, but not in CoCr-EES. With respect to procedural techniques, small-vessel lesions were treated more frequently with noncompliant balloons at post-dilatation but using significantly lower pressure in the Absorb BVS arm. In contrast, tapered-vessel lesions were post-dilated at equivalent pressure but with significantly smaller balloon catheters in the Absorb BVS arm, compared with the CoCr-EES arm. CONCLUSIONS: The significantly smaller device expansion especially in small vessels may account for the poorer outcomes of Absorb BVS in this lesion type. Appropriate optimization strategy, possibly different between polymeric and metallic devices, needs to be established for bioresorbable scaffold technology. (AVJ-301 Clinical Trial: A Clinical Evaluation of AVJ-301 Absorb™ BVS) in Japanese Population [ABSORB JAPAN]; NCT01844284).


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
17.
Am Heart J ; 154(2): 361-5, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17643589

RESUMO

BACKGROUND: Recurrent restenosis may occur after drug-eluting stent implantation for in-stent restenosis (ISR) of bare metal stents (BMSs), especially in areas involving drug-eluting stent gaps. METHODS: To investigate the details of neointimal progression and luminal narrowing after the treatment of ISR using sirolimus-eluting stents (SESs), serial intravascular ultrasound analysis was performed in 65 patients with ISR at postintervention and at 6-month follow-up. The total stented segment was categorized into 3 compartments: new SES (N), new SES and old BMS overlap (N/O), and old BMS (O). In each of the 190 compartments, serial intravascular ultrasound parameters were analyzed at the cross section of the maximum change in neointimal area (delta neointimal area) from postintervention to follow-up or the minimum lumen area at follow-up if delta neointimal area was 0. Minimum lumen area in each compartment was also investigated serially. RESULTS: At postintervention, lumen area was the smallest in compartment N/O (N 5.8 +/- 1.5, N/O 5.1 +/- 1.3, O 6.0 +/- 1.4 mm2, P = .005). Not only the average of maximum delta neointimal area (N 0.2 +/- 0.4, N/O 0.2 +/- 0.4, O 0.8 +/- 1.0 mm2, P < .0001) but also the frequency of minimum lumen area decreasing from > or = 4.0 mm2 at postintervention to < 4.0 mm2 at follow-up (N 4.0%, N/O 5.1%, O 23.5%, P = .012) was the largest in compartment O. CONCLUSIONS: Neointimal progression and consequent luminal narrowing tend to occur where BMS is uncovered with SES in treatment of ISR, even in the absence of an obvious stenosis at postintervention.


Assuntos
Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/tratamento farmacológico , Imunossupressores/administração & dosagem , Sirolimo/administração & dosagem , Túnica Íntima/diagnóstico por imagem , Ultrassonografia de Intervenção , Idoso , Anatomia Transversal , Progressão da Doença , Sistemas de Liberação de Medicamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Stents
18.
Transplantation ; 84(9): 1097-102, 2007 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-17998863

RESUMO

BACKGROUND: We previously reported that negative remodeling, not plaque progression, correlated with lumen loss during the first year after cardiac transplantation and that cytomegalovirus antibody seropositivity correlated with increased negative remodeling and greater lumen loss. Whether these findings persist between years 1 and 2 after transplantation is unknown. METHODS: Serial 3-dimensional intravascular ultrasound analysis in the left anterior descending coronary artery was performed in 30 cardiac transplant recipients at year 1 and 2 after transplantation. Vessel, lumen, and plaque area were determined at 0.5-mm axial intervals in the first 50 mm of the left anterior descending coronary artery, and volumes were computed using Simpson's method. Univariate and multivariate regression analyses were performed to identify clinical predictors of change in coronary dimensions. RESULTS: Although mean vessel area did not change (13.6+/-3.4 to 13.4+/-3.3 mm/mm(3), P=0.45), mean plaque area increased (3.4+/-2.3 to 3.8+/-2.2 mm/mm(3), P=0.012), resulting in significant mean lumen area loss (10.3+/-2.5 to 9.6+/-2.3 mm/mm(3), P=0.016). However, the degree of luminal change strongly correlated with the degree of change in vessel size (R=0.81, P<0.0001), but not with change in plaque amount (R=-0.19, P=0.32). In fact, in 57% of the patients who demonstrated lumen loss, negative remodeling contributed more to lumen loss than did plaque progression. Diabetes at 2 years was the only significant independent clinical predictor of plaque progression and lumen loss. CONCLUSION: Despite significant plaque progression, negative remodeling correlated with coronary lumen loss between years 1 and 2 after cardiac transplantation.


Assuntos
Vasos Coronários/patologia , Transplante de Coração/patologia , Adulto , Aorta/diagnóstico por imagem , Aorta/patologia , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Infecções por Citomegalovirus/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Ultrassonografia
19.
Am J Cardiol ; 99(4): 491-3, 2007 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-17293191

RESUMO

Whether gender affects long-term outcomes after bare metal stent implantation remains controversial. The aim of this study was to examine the impact of gender on neointimal hyperplasia in a large cohort of patients after stent implantation using 3-dimensional intravascular ultrasound. Lumen and stent areas were manually traced at 0.5-mm intervals throughout the stented segment. Using Simpson's method, lumen, stent, and neointimal (stent - lumen) volumes were calculated and standardized by stent length. Women were older, presented more often with hyperlipidemia or hypertension, and had smaller reference vessel diameter and mean stent area, compared with men. Although neointimal hyperplasia and neointimal thickness in women were similar to that in men, the percentage of neointimal hyperplasia (neointimal area divided by stent area) was higher in women due to the smaller stent area. After adjusting for stent area, the percentage of neointimal hyperplasia did not differ by gender. In conclusion, the results of this study indicate that neointimal hyperplasia after bare metal stent implantation in women is similar to that seen in men. Despite the similarity in outcome, there are several gender-specific differences in baseline characteristics.


Assuntos
Reestenose Coronária/patologia , Stents , Túnica Íntima/patologia , Reestenose Coronária/diagnóstico por imagem , Feminino , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais , Resultado do Tratamento , Túnica Íntima/diagnóstico por imagem , Ultrassonografia de Intervenção
20.
Am J Cardiol ; 99(10): 1394-8, 2007 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-17493467

RESUMO

Coronary culprit lesions with plaque rupture (PR) have been treated with different coronary interventions. However, it is unknown whether the presence of PR affects the restenotic process after coronary intervention. One hundred forty-two patients undergoing coronary bare metal stent implantation were enrolled in the present retrospective analysis. Case selection was based on availability of intravascular ultrasound (IVUS) and quantitative coronary angiographic examinations at baseline (before and after intervention) and at follow-up. Serial comparative analyses included qualitative and quantitative features of the culprit lesion and reference segments. PR was defined as an intraplaque cavity in communication with the lumen in the presence of a residual, disrupted cap. Patients were categorized according to the presence/absence of PR. Pre-interventional IVUS detected PR in 54 patients (38%). Baseline patient demographics were similar between the +PR and -PR groups. Quantitative IVUS analysis showed higher rates of positive remodeling and larger vessel and plaque areas in the +PR compared with -PR lesions (p <0.001 for all). At follow-up (7.2 +/- 2.6 months), no statistically significant difference was observed between the 2 groups in quantitative coronary angiographic or IVUS measurements. In conclusion, culprit lesions with PR exhibited larger plaque mass and higher rates of positive remodeling at preintervention IVUS examination. However, when treated with bare metal stents, the absence/presence of preintervention PR was not found to affect the rate or severity of in-stent restenosis in these culprit lesions.


Assuntos
Angina Pectoris/cirurgia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Stents/efeitos adversos , Ultrassonografia de Intervenção , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/lesões , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Falha de Prótese , Projetos de Pesquisa , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA