Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Am J Physiol Heart Circ Physiol ; 327(1): H000, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38819383

RESUMO

Nitric oxide (NO) inhalation improves pulmonary hemodynamics in participants with pulmonary arterial hypertension (PAH). Although it can reduce pulmonary vascular resistance (PVR) in PAH, its impact on the dynamic mechanics of pulmonary arteries and its potential difference between control and participants with PAH remain unclear. PA impedance provides a comprehensive description of PA mechanics. With an arterial model, PA impedance can be parameterized into peripheral pulmonary resistance (Rp), arterial compliance (Cp), characteristic impedance of the proximal arteries (Zc), and transmission time from the main PA to the reflection site. This study investigated the effects of inhaled NO on PA impedance and its associated parameters in control and monocrotaline-induced pulmonary arterial hypertension (MCT-PAH) male rats (6/group). Measurements were obtained at baseline and during NO inhalation at 40 and 80 ppm. In both groups, NO inhalation decreased PVR and increased the left atrial pressure. Notably, its impact on PA impedance was frequency dependent, as revealed by reduced PA impedance modulus in the low-frequency range below 10 Hz, with little effect on the high-frequency range. Furthermore, NO inhalation attenuated Rp, increased Cp, and prolonged transmission time without affecting Zc. It reduced Rp more pronouncedly in MCT-PAH rats, whereas it increased Cp and delayed transmission time more effectively in control rats. In conclusion, the therapeutic effects of inhaled NO on PA impedance were frequency dependent and may differ between the control and MCT-PAH groups, suggesting that the effect on the mechanics differs depending on the pathological state.NEW & NOTEWORTHY Nitric oxide inhalation decreased pulmonary arterial impedance in the low-frequency range (<10 Hz) with little impact on the high-frequency range. It reduced peripheral pulmonary resistance more pronouncedly in pulmonary hypertension rats, whereas it increased arterial compliance and transmission time in control rats. Its effect on the mechanics of the pulmonary arteries may differ depending on the pathological status.


Assuntos
Óxido Nítrico , Artéria Pulmonar , Resistência Vascular , Animais , Masculino , Óxido Nítrico/metabolismo , Artéria Pulmonar/fisiopatologia , Artéria Pulmonar/efeitos dos fármacos , Administração por Inalação , Resistência Vascular/efeitos dos fármacos , Monocrotalina , Ratos , Ratos Sprague-Dawley , Modelos Animais de Doenças , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/induzido quimicamente , Hipertensão Pulmonar/tratamento farmacológico , Hipertensão Arterial Pulmonar/fisiopatologia , Hipertensão Arterial Pulmonar/tratamento farmacológico , Hipertensão Arterial Pulmonar/induzido quimicamente , Pressão Arterial/efeitos dos fármacos
2.
Am J Physiol Regul Integr Comp Physiol ; 326(3): R230-R241, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38223938

RESUMO

Although body fluid volume control by the kidneys may be classified as a long-term arterial pressure (AP) control system, it does not necessarily follow that the urine flow (UF) response to changes in AP is slow. We quantified the dynamic characteristics of the UF response to short-term AP changes by changing mean AP between 60 mmHg and 100 mmHg every 10 s according to a binary white noise sequence in anesthetized rats (n = 8 animals). In a baro-on trial (the carotid sinus baroreflex was enabled), the UF response represented the combined synergistic effects of pressure diuresis (PD) and neurally mediated antidiuresis (NMA). In a baro-fix trial (the carotid sinus pressure was fixed at 100 mmHg), the UF response mainly reflected the effect of PD. The UF step response was quantified using the sum of two exponential decay functions. The fast and slow components had time constants of 6.5 ± 3.6 s and 102 ± 85 s (means ± SD), respectively, in the baro-on trial. Although the gain of the fast component did not differ between the two trials (0.49 ± 0.21 vs. 0.66 ± 0.22 µL·min-1·kg-1·mmHg-1), the gain of the slow component was greater in the baro-on than in the baro-fix trial (0.51 ± 0.14 vs. 0.09 ± 0.39 µL·min-1·kg-1·mmHg-1, P = 0.023). The magnitude of NMA relative to PD was calculated to be 32.2 ± 29.8%. In conclusion, NMA contributed to the slow component, and its magnitude was approximately one-third of that of the effect of PD.NEW & NOTEWORTHY We quantified short-term dynamic characteristics of the urine flow (UF) response to arterial pressure (AP) changes using white noise analysis. The UF step response approximated the sum of two exponential decay functions with time constants of ∼6.5 s and 102 s. The neurally mediated antidiuretic (NMA) effect contributed to the slow component of the UF step response, with the magnitude of approximately one-third of that of the pressure diuresis (PD) effect.


Assuntos
Pressão Arterial , Barorreflexo , Animais , Ratos , Barorreflexo/fisiologia , Pressão Sanguínea/fisiologia , Artérias Carótidas , Diurese
3.
Am J Physiol Regul Integr Comp Physiol ; 324(2): R260-R270, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36572552

RESUMO

Accentuated antagonism refers to a phenomenon in which the vagal effect on heart rate (HR) is augmented by background sympathetic tone. The dynamic aspect of accentuated antagonism remains to be elucidated during different levels of vagal nerve stimulation (VNS) intensity. We performed VNS on anesthetized rats (n = 8) according to a binary white noise signal with a switching interval of 500 ms at three different stimulation rates (low-intensity: 0-10 Hz, moderate-intensity: 0-20 Hz, and high-intensity: 0-40 Hz). The transfer function from VNS to HR was estimated with and without concomitant tonic sympathetic nerve stimulation (SNS) at 5 Hz. The asymptotic low-frequency (LF) gain (in beats/min/Hz) of the transfer function increased with SNS regardless of the VNS rate [low-intensity: 3.93 ± 0.70 vs. 5.82 ± 0.65 (P = 0.021), moderate-intensity: 3.87 ± 0.62 vs. 5.36 ± 0.53 (P = 0.018), high-intensity: 4.77 ± 0.85 vs. 7.39 ± 1.36 (P = 0.011)]. Moreover, SNS slightly increased the ratio of high-frequency (HF) gain to the LF gain. These effects of SNS were canceled by the pretreatment of ivabradine, an inhibitor of hyperpolarization-activated cyclic nucleotide-gated channels, in another group of rats (n = 6). Although background sympathetic tone antagonizes the vagal effect on mean HR, it enables finer HR control by increasing the dynamic gain of the vagal HR transfer function regardless of VNS intensity. When interpreting the HF component of HR variability, the augmenting effect from background sympathetic tone needs to be considered.


Assuntos
Estimulação do Nervo Vago , Ratos , Animais , Frequência Cardíaca/fisiologia , Nervo Vago/fisiologia , Sistema Nervoso Simpático/fisiologia , Estimulação Elétrica
4.
Bioorg Med Chem Lett ; 58: 128519, 2022 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-34952176

RESUMO

A decrease in pH is observed in most solid tumors, thus, the development of drug delivery systems that respond to slightly acidic extracellular pH environment is important in providing tumor-targeted therapies. DNA aggregates can act as useful drug delivery agents, and therefore, we designed an artificial oligodeoxynucleotides (ODNs) that formed an aggregate only under acidic conditions in this study. In other words, we expected that if we could make DNA aggregates that form only in an acidic environment and that encapsulate drugs, it would be possible to transport drugs to tumor tissues selectively. Nitrophenol derivatives, which underwent protonation and deprotonation in response to pH changes, was introduced into ODNs. The ODNs formed aggregates under weakly acidic conditions because of expression of amphiphilicity, which was induced by protonation of nitrophenol unit, and were smoothly taken up into cells. We also found that the aggregates transported anticancer drug, 5FU, into acidified cells to show cytotoxic effects.


Assuntos
Antimetabólitos Antineoplásicos/farmacologia , Sistemas de Liberação de Medicamentos , Fluoruracila/farmacologia , Nitrofenóis/química , Oligodesoxirribonucleotídeos/química , Células A549 , Antimetabólitos Antineoplásicos/química , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Relação Dose-Resposta a Droga , Ensaios de Seleção de Medicamentos Antitumorais , Fluoruracila/química , Humanos , Concentração de Íons de Hidrogênio , Estrutura Molecular , Relação Estrutura-Atividade
5.
Circ J ; 85(7): 979-988, 2021 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-33907051

RESUMO

BACKGROUND: The effect of sex on mortality is controversial; furthermore, sex differences in left ventricular (LV) remodeling after transcatheter aortic valve implantation (TAVI) remain unknown.Methods and Results:This study included 2,588 patients (1,793 [69.3%] female) enrolled in the Optimized CathEter vAlvular iNtervention (OCEAN)-TAVI Japanese multicenter registry between October 2013 and May 2017. We retrospectively analyzed the effect of sex on mortality, and evaluated changes in the LV mass index (LVMI) after TAVI. Female sex was significantly associated with lower all-cause and cardiovascular mortality (log-rank P<0.001 for both). Multivariate analysis showed that female sex was independently associated with lower cumulative long-term mortality (hazard ratio 0.615; 95% confidence interval 0.512-0.738; P<0.001). Regression in the LVMI was observed in both sexes, and there was no significant difference in the percentage LVMI regression from baseline to 1 year after TAVI between women and men. Women had a survival advantage compared with men among patients with LVMI regression at 1 year, but not among patients with no LVMI regression. CONCLUSIONS: We found that female sex is associated with better survival outcomes after TAVI in a large Japanese registry. Although LVMI regression was observed in women and men after TAVI, post-procedural LV mass regression may be related to the sex differences in mortality.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Hipertrofia Ventricular Esquerda , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Remodelação Ventricular
6.
Indian Pacing Electrophysiol J ; 21(2): 67-72, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33556501

RESUMO

BACKGROUND: Difficulties are often encountered while controlling atrial fibrillation (AF), especially in hemodialysis (HD) patients. Previous data revealed that cryoballoon ablation (CBA) for treating paroxysmal atrial fibrillation (PAF) was not inferior to radiofrequency ablation (RFA); however, HD patients were excluded in this prior trial. Thus, the efficacy of CBA for HD patients is still unknown. METHODS: This retrospective study analyzed HD patients who underwent catheter ablation (CA) for AF from August 2011 to June 2019. Patients who received CBA (CBA group) and those who received RFA (RFA group) were compared. The primary endpoint was defined as freedom from a composite outcome (a documented recurrence of any atrial tachyarrhythmia or a prescription of antiarrhythmic drugs) at one year after CA. RESULTS: The RFA and CBA groups were composed of 21 and 23 patients, respectively. Freedom from a composite outcome was 58.4% in the RFA group and 68.2% in the CBA group (Log-rank: p = 0.571). CONCLUSION: Our results suggest that patients on HD with AF who were treated with CBA tended to have better outcomes than patients treated with RFA. Therefore, CBA could be a suitable ablation method for HD patients.

7.
Catheter Cardiovasc Interv ; 96(1): 20-28, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32096918

RESUMO

OBJECTIVE: To evaluate the short-, long-term clinical and angiographic outcomes after treatment of true bifurcation lesions using a modified jailed balloon technique (MJBT). BACKGROUND: Percutaneous coronary intervention (PCI) for true bifurcation lesions has high risk for adverse events. Side branch (SB) occlusion is one of the most serious complications. Therefore, novel strategies to avoid SB occlusion during main branch stenting and to keep its patency are important. METHODS AND RESULTS: Between February 2015 and February 2018, 328 patients with 349 true bifurcation lesions underwent PCI using MJBT. True bifurcation lesions were defined as Medina classifications (1.1.1), (1.0.1) or (0.1.1) lesions. We investigated the procedural and long-term clinical outcomes. Furthermore, angiographic outcomes were assessed at follow-up diagnostic angiography. The mean age of patients was 71.6 ± 9.9 years. Procedural success was achieved in all patients; postoperative SB occlusion was noted in only one patient (0.3%). The cumulative incidence of all-cause death was 23 patients (7.0%) in the follow-up period (median 717 days). Target lesion revascularization was performed in 19 patients (5.8%) with 23 lesions (6.6%), and 0.6% of myocardial infarction and 0% of definite stent thrombosis were observed. Angiographic follow-up was performed in 243 patients (74.1%); the percent diameter stenosis in SB was not significantly different between after the index procedure and follow-up angiography. CONCLUSIONS: This MJBT is safe and effective in preserving SB patency for true bifurcation lesions. Furthermore, long-term clinical and angiographic outcomes after MJBT are feasible.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana/terapia , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
8.
Heart Vessels ; 35(10): 1323-1330, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32296926

RESUMO

Coronary artery disease is common in patients on dialysis; there is a high rate of bleeding events after percutaneous coronary intervention (PCI) in such patients. We investigated the impact of bleeding events after PCI on mortality in patients on hemodialysis. We included 386 consecutive hemodialysis patients who underwent PCI using a drug-eluting stent (DES) between September 2004 and December 2017 in our hospital, and investigated the impact of bleeding events on all-cause mortality after PCI. Bleeding events were assessed by the Thrombolysis in Myocardial Infarction (TIMI) bleeding definition within 24 months after PCI. A total of 42 patients experienced bleeding events. Of these, 30 patients (71.4%) had TIMI major bleeding events and 12 patients (28.6%) had TIMI minor bleeding events. Patients with bleeding events had significantly higher mortality than patients without bleeding events (survival rate, 55.1% vs 81.5%, log-rank: p < 0.001). These results suggest that bleeding events after PCI with a DES are notably associated with all-cause mortality among patients on hemodialysis. This is the first report about relationship between bleeding events and mortality to focus on patients on hemodialysis.


Assuntos
Doença da Artéria Coronariana/terapia , Hemorragia/etiologia , Nefropatias/terapia , Intervenção Coronária Percutânea/efeitos adversos , Diálise Renal , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Stents Farmacológicos , Feminino , Hemorragia/mortalidade , Humanos , Nefropatias/diagnóstico , Nefropatias/mortalidade , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Diálise Renal/efeitos adversos , Diálise Renal/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
J Interv Cardiol ; 2019: 5345178, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31772534

RESUMO

OBJECTIVES: This study investigated the relationship between the timing of ventricular tachycardia or ventricular fibrillation (VT or VF) and prognosis in patients undergoing primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI). BACKGROUND: It is unknown whether the timing of VT/VF occurrence affects the prognosis of patients with AMI. METHODS: From January 2004 to December 2014, 1004 patients with AMI underwent primary PCI. Of these patients, 888 did not have VT/VF (non-VT/VF group) and 116 had sustained VT/VF during prehospitalization or hospitalization. Patients with VT/VF were divided into two groups: early VT/VF (VT/VF occurrence before and within 2 days of admission, 92 patients) and late VT/VF (VT/VF occurrence >2 days after admission; 24 patients) groups. RESULTS: The frequency of VT/VF occurrence was high between the day of admission and the 2nd day and between days 6 and 10 of hospitalization. The late VT/VF group had a significantly longer onset-to-balloon time, lower ejection fraction, poorer renal function, and higher creatine phosphokinase (CK)-MB level on admission (p< 0.001). They also had a lower 30-day cardiac survival rate than the early VT/VF and non-VT/VF groups (42% vs. 76% vs. 96%, p < 0.001). Moreover, independent predictors of in-hospital cardiac mortality among patients with AMI who had sustained VT/VF were higher peak CK-MB [Odds ratio (OR: 1.001, 95%confidence interval (CI): 1.000-1.002, p= 0.03)], higher Killip class (OR: 1.484, 95%CI 1.017-2.165, p= 0.04), and late VT/VF (OR: 3.436, 95%CI 1.115-10.59, p= 0.03). CONCLUSIONS: The timing of VT/VF occurrences had a bimodal peak. Although late VT/VF occurrence after primary PCI was less frequent than early VT/VF occurrence, patients with late VT/VF had a very poor prognosis.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Complicações Pós-Operatórias , Taquicardia Ventricular , Fibrilação Ventricular , Idoso , Feminino , Humanos , Incidência , Japão , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Prognóstico , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade , Fatores de Tempo , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/mortalidade
10.
Vet Immunol Immunopathol ; 269: 110716, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38308864

RESUMO

Myeloid-derived suppressor cells (MDSCs) are immature cells with immunosuppressive properties found in the tumor microenvironment. MDSCs are divided into two major subsets: polymorphonuclear MDSCs (PMN-MDSCs) and monocytic MDSCs (M-MDSCs). Both MDSC subsets contribute to the creation of an immunosuppressive environment for tumor progression. In humans, patients with high levels of MDSCs show worse outcomes for several types of cancers. However, the association between MDSCs and clinical features has rarely been investigated in canine studies. In the present study, we measured the proportion of PMN-MDSCs and M-MDSCs in the peripheral blood and tumor tissue of dogs with hepatocellular carcinoma (HCC), prostate cancer (PC), transitional cell carcinoma (TCC), lymphoma, and pulmonary adenocarcinoma. Additionally, we examined immunosuppressive ability of PMN-MDSCs and M-MDSCs in peripheral blood mononuclear cells of TCC case on CD4+, CD8+ and interferon-γ+ cells and investigated the relationships of MDSCs with clinical features and outcomes. PMN-MDSCs increased in HCC, PC, TCC, and lymphoma. In contrast, M-MDSCs increased in the TCC. Both PMN-MDSCs and M-MDSCs exhibited immunosuppressive effects on CD8+, CD4+ and interferon-γ+ cells. In dogs with TCC, lymph node metastasis was associated with high level of PMN-MDSCs but not with M-MDSCs. High levels of both PMN-MDSCs and M-MDSCs were related to advanced tumor stage. Kaplan-Meier analysis revealed that high levels of both PMN-MDSCs and M-MDSCs were significantly associated with shorter overall survival. In addition, the Cox proportional hazard regression model showed that M-MDSCs and the tumor stage were independent prognostic factors for TCC. These results suggest that PMN-MDSCs and M-MDSCs may be involved in tumor progression and could be prognostic factors and promising therapeutic targets in dogs with TCC.


Assuntos
Carcinoma Hepatocelular , Carcinoma de Células de Transição , Doenças do Cão , Neoplasias Hepáticas , Linfoma , Células Supressoras Mieloides , Humanos , Masculino , Animais , Cães , Células Supressoras Mieloides/metabolismo , Carcinoma Hepatocelular/veterinária , Neoplasias Hepáticas/veterinária , Interferon gama/metabolismo , Leucócitos Mononucleares , Carcinoma de Células de Transição/veterinária , Prognóstico , Linfoma/veterinária , Microambiente Tumoral , Doenças do Cão/metabolismo
11.
Hypertens Res ; 47(5): 1298-1308, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38485776

RESUMO

The acetylcholinesterase inhibitor donepezil restores autonomic balance, reduces inflammation, and improves long-term survival in rats with chronic heart failure (CHF) following myocardial infarction (MI). As arterial hypertension is associated with a significant risk of cardiovascular death, we investigated the effectiveness of donepezil in treating CHF in spontaneously hypertensive rats (SHR). CHF was induced in SHR by inducing permanent MI. After 2 weeks, the surviving SHR were randomly assigned to sham-operated (SO), untreated (UT), or oral donepezil-treated (DT, 5 mg/kg/day) groups, and various vitals and parameters were monitored. After 7 weeks of treatment, heart rate and arterial hypertension reduced significantly in DT rats than in UT rats. Donepezil treatment improved 50-day survival (41% to 80%, P = 0.004); suppressed progression of cardiac hypertrophy, cardiac dysfunction (cardiac index: 133 ± 5 vs. 112 ± 5 ml/min/kg, P < 0.05; left ventricular end-diastolic pressure: 12 ± 3 vs. 22 ± 2 mmHg, P < 0.05; left ventricular +dp/dtmax: 5348 ± 338 vs. 4267 ± 114 mmHg/s, P < 0.05), systemic inflammation, and coronary artery remodeling (wall thickness: 26.3 ± 1.4 vs. 34.7 ± 0.7 µm, P < 0.01; media-to-lumen ratio: 3.70 ± 0.73 vs. 8.59 ± 0.84, P < 0.001); increased capillary density; and decreased plasma catecholamine, B-type natriuretic peptide, arginine vasopressin, and angiotensin II levels. Donepezil treatment attenuated cardiac and coronary artery remodeling, mitigated cardiac dysfunction, and significantly improved the prognosis of SHR with CHF.


Assuntos
Donepezila , Indanos , Infarto do Miocárdio , Piperidinas , Ratos Endogâmicos SHR , Remodelação Ventricular , Animais , Donepezila/uso terapêutico , Donepezila/farmacologia , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/complicações , Piperidinas/farmacologia , Piperidinas/uso terapêutico , Ratos , Masculino , Indanos/farmacologia , Indanos/uso terapêutico , Remodelação Ventricular/efeitos dos fármacos , Hipertensão/tratamento farmacológico , Hipertensão/complicações , Prognóstico , Progressão da Doença , Pressão Sanguínea/efeitos dos fármacos , Inibidores da Colinesterase/uso terapêutico , Inibidores da Colinesterase/farmacologia , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca/efeitos dos fármacos
12.
Int J Cardiol ; 410: 132244, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38851541

RESUMO

BACKGROUND: Left ventricular (LV) unloading by Impella, an intravascular microaxial pump, has been shown to exert dramatic cardioprotective effects in acute clinical settings of cardiovascular diseases. Total Impella support (no native LV ejection) is far more efficient in reducing LV energetic demand than partial Impella support, but the manual control of pump speed to maintain stable LV unloading is difficult and impractical. We aimed to develop an Automatic IMpella Optimal Unloading System (AIMOUS), which controls Impella pump speed to maintain LV unloading degree using closed-feedback control. We validated the AIMOUS performance in an animal model. METHODS: In dogs, we identified the transfer function from pump speed to LV systolic pressure (LVSP) under total support conditions (n = 5). Using the transfer function, we designed the feedback controller of AIMOUS to keep LVSP at 40 mmHg and examined its performance by volume perturbations (n = 9). Lastly, AIMOUS was applied in the acute phase of ischemia-reperfusion in dogs. Four weeks after ischemia-reperfusion, we assessed LV function and infarct size (n = 10). RESULTS: AIMOUS maintained constant LVSP, thereby ensuring a stable LV unloading condition regardless of volume withdrawal or infusion (±8 ml/kg from baseline). AIMOUS in the acute phase of ischemia-reperfusion markedly improved LV function and reduced infarct size (No Impella support: 13.9 ± 1.3 vs. AIMOUS: 5.7 ± 1.9%, P < 0.05). CONCLUSIONS: AIMOUS is capable of maintaining optimal LV unloading during periods of unstable hemodynamics. Automated control of Impella pump speed in the acute phase of ischemia-reperfusion significantly reduced infarct size and prevented subsequent worsening of LV function.


Assuntos
Coração Auxiliar , Hemodinâmica , Infarto do Miocárdio , Função Ventricular Esquerda , Cães , Animais , Hemodinâmica/fisiologia , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Função Ventricular Esquerda/fisiologia , Masculino , Modelos Animais de Doenças , Automação
13.
Intensive Care Med Exp ; 12(1): 13, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38361021

RESUMO

BACKGROUND: ECPELLA, a combination of veno-arterial (VA) extracorporeal membrane oxygenation (ECMO) and Impella, a percutaneous left ventricular (LV) assist device, has emerged as a novel therapeutic option in patients with severe cardiogenic shock (CS). Since multiple cardiovascular and pump factors influence the haemodynamic effects of ECPELLA, optimising ECPELLA management remains challenging. In this study, we conducted a comprehensive simulation study of ECPELLA haemodynamics. We also simulated global oxygen delivery (DO2) under ECPELLA in severe CS and acute respiratory failure as a first step to incorporate global DO2 into our developed cardiovascular simulation. METHODS AND RESULTS: Both the systemic and pulmonary circulations were modelled using a 5-element resistance‒capacitance network. The four ventricles were represented by time-varying elastances with unidirectional valves. In the scenarios of severe LV dysfunction, biventricular dysfunction with normal pulmonary vascular resistance (PVR, 0.8 Wood units), and biventricular dysfunction with high PVR (6.0 Wood units), we compared the changes in haemodynamics, pressure-volume relationship (PV loop), and global DO2 under different VA-ECMO flows and Impella support levels. RESULTS: In the simulation, ECPELLA improved total systemic flow with a minimising biventricular pressure-volume loop, indicating biventricular unloading in normal PVR conditions. Meanwhile, increased Impella support level in high PVR conditions rendered the LV-PV loop smaller and induced LV suction in ECPELLA support conditions. The general trend of global DO2 was followed by the changes in total systemic flow. The addition of veno-venous ECMO (VV-ECMO) augmented the global DO2 increment under ECPELLA total support conditions. CONCLUSIONS: The optimal ECPELLA support increased total systemic flow and achieved both biventricular unloading. The VV-ECMO effectively improves global DO2 in total ECPELLA support conditions.

14.
Front Vet Sci ; 11: 1374356, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38881786

RESUMO

Introduction: Intra-operative hypotension is a common complication of surgery under general anesthesia in dogs and humans. Computer-controlled closed-loop infusion systems of norepinephrine (NE) have been developed and clinically applied for automated optimization of arterial pressure (AP) and prevention of intra-operative hypotension in humans. This study aimed to develop a simple computer-controlled closed-loop infusion system of NE for the automated control of the mean arterial pressure (MAP) in dogs with isoflurane-induced hypotension and to validate the control of MAP by the developed system. Methods: NE was administered via the cephalic vein, whereas MAP was measured invasively by placing a catheter in the dorsal pedal artery. The proportional-integral-derivative (PID) controller in the negative feedback loop of the developed system titrated the infusion rate of NE to maintain the MAP at the target value of 60 mmHg. The titration was updated every 2 s. The performance of the developed system was evaluated in six laboratory Beagle dogs under general anesthesia with isoflurane. Results: In the six dogs, when the concentration [median (interquartile range)] of inhaled isoflurane was increased from 1.5 (1.5-1.5)% to 4 (4-4)% without activating the system, the MAP was lowered from 95 (91-99) to 41 (37-42) mmHg. In contrast, when the concentration was increased from 1.5 (1.0-1.5)% to 4 (4-4.8)% for a 30-min period and the system was simultaneously activated, the MAP was temporarily lowered from 92 (89-95) to 47 (43-49) mmHg but recovered to 58 (57-58) mmHg owing to the system-controlled infusion of NE. If the acceptable target range for MAP was defined as target MAP ±5 mmHg (55 ≤ MAP ≤65 mmHg), the percentage of time wherein the MAP was maintained within the acceptable range was 96 (89-100)% in the six dogs during the second half of the 30-min period (from 15 to 30 min after system activation). The median performance error, median absolute performance error, wobble, and divergence were - 2.9 (-4.7 to 1.9)%, 2.9 (2.0-4.7)%, 1.3 (0.8-1.8)%, and - 0.24 (-0.34 to -0.11)%·min-1, respectively. No adverse events were observed during the study period, and all dogs were extubated uneventfully. Conclusion: This system was able to titrate the NE infusion rates in an accurate and stable manner to maintain the MAP within the predetermined target range in dogs with isoflurane-induced hypotension. This system can be a potential tool in daily clinical practice for the care of companion dogs.

15.
IEEE Trans Biomed Eng ; PP2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38949936

RESUMO

OBJECTIVE: Total artificial heart (TAH) using dual rotary blood pumps (RBPs) is a potential treatment for end-stage heart failure. A well-noted challenge with RBPs is their low sensitivity to preload, which can lead to venous congestion and ventricular suction. To address this issue, we have developed an innovative closed-loop control system of dual RBPs in TAH. This system emulates the Frank-Starling law of the heart in controlling RBPs while monitoring stressed blood volume (V) based on the circulatory equilibrium framework. We validated the system in in-vivo experiments. METHODS: In 9 anesthetized dogs, we prepared a TAH circuit using 2 centrifugal-type RBPs. We first investigated whether the flow and inlet atrial pressure in each RBP adhered to a logarithmic Frank-Starling curve. We then examined whether the RBP flows and atrial pressures were maintained stably during aortic occlusion (AO) and pulmonary cannula stenosis (PS), whether averaged flow of dual RBPs and bilateral atrial pressures were controlled to their predefined target values for a specific V, and whether this system could maintain the atrial pressures within predefined control ranges under significant changes in V. RESULTS: This system effectively emulated the logarithmic Frank-Starling curve. It robustly stabilized the flow and atrial pressures during AO and PS without venous congestion or ventricular suction, accurately achieved target values in averaged flow and atrial pressures, and efficaciously maintained these pressures within the control ranges. CONCLUSION: This system controls dual RBPs in TAH accurately and stably. SIGNIFICANCE: This system may accelerate clinical application of TAH with dual RBPs.

16.
Artigo em Inglês | MEDLINE | ID: mdl-38083538

RESUMO

Acute heart failure imperils multiple organs, including the heart. Elucidating the impact of drug therapies across this multidimensional hemodynamic system remains a challenge. This paper proposes a simulator that analyzes the impact of drug therapies on four dimensions of hemodynamics: left atrial pressure, cardiac output, mean arterial pressure, and myocardial oxygen consumption. To mathematically formulate hemodynamics, the analytical solutions of four-dimensional hemodynamics and the direction of its change are derived as functions of cardiovascular parameters: systemic vascular resistance, cardiac contractility, heart rate, and stressed blood volume. Furthermore, a drug library which represents the multi-dependency effect of drug therapies on cardiovascular parameters was identified in animal experiments. In evaluating the accuracy of our derived hemodynamic direction, the average angular error of predicted versus observed direction was 18.85[deg] after four different drug infusions for acute heart failure in animal experiments. Finally, the impact of drug therapies on four-dimensional hemodynamics was analyzed in three different simulation settings. One result showed that, even when drug therapies were simulated with simple rules according to the Forrester classification, the predicted direction of hemodynamic change matched the expected direction in more than 80% in 963 different AHF patient scenarios. Our developed simulator visualizes the impact of drug therapies on four-dimensional hemodynamics so intuitively that it can support clinicians' decision-making to protect multiple organs.


Assuntos
Insuficiência Cardíaca , Hemodinâmica , Animais , Humanos , Insuficiência Cardíaca/tratamento farmacológico , Débito Cardíaco , Resistência Vascular , Frequência Cardíaca
17.
IEEE Trans Biomed Eng ; 70(2): 703-714, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36001510

RESUMO

OBJECTIVE: The objective of this study was to develop a novel triple-bladder cuff method for accurate and automated estimation of systolic (SBP) and diastolic (DBP) blood pressure and validate its reliability in animal experiments. METHODS: The cuff is composed of three bladders each measured one-third the width of a conventional BP cuff, which are designed to measure oscillatory pulsation at the proximal, middle, and distal segments of the upper arm. This structure allows evaluation of the pulse wave propagation in the brachial artery under the cuff. SBP is estimated (SBPe) by detecting resumption of systolic arterial flow based on statistical similarity in oscillatory pulse traces between the proximal and distal segments. DBP is estimated (DBPe) based on the relation between pulse wave velocity and transmural pressure at diastole in the brachial artery. In 7 anesthetized goats, we compared SBPe and DBPe to reference SBP and DBP, respectively, measured by an intra-arterial catheter. BP was perturbed by infusing nitroprusside or noradrenaline. RESULTS: SBP correlated strongly with SBPe in each animal [mean coefficient of determination (R2) = 0.98 ± 0.01]. Mean ± standard deviation of errors between SBP and SBPe was 0.0 ± 4.9 mmHg. DBP correlated strongly with DBPe in each animal (R2 = 0.96 ± 0.03). Mean ± standard deviation of errors between DBP and DBPe was 0.0 ± 6.3 mmHg. CONCLUSION: This method estimates SBP and DBP with acceptable accuracy. SIGNIFICANCE: Accurate and automated BP estimation by this method may potentially optimize antihypertensive treatment in patients with hypertension.


Assuntos
Determinação da Pressão Arterial , Artéria Braquial , Animais , Pressão Sanguínea/fisiologia , Artéria Braquial/fisiologia , Determinação da Pressão Arterial/métodos , Análise de Onda de Pulso , Reprodutibilidade dos Testes , Bexiga Urinária
18.
J Physiol Sci ; 73(1): 20, 2023 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-37704939

RESUMO

Sodium-glucose cotransporter 2 (SGLT2) inhibitors have exerted cardioprotective effects in clinical trials, but underlying mechanisms are not fully understood. As mitigating sympathetic overactivity is of major clinical concern in the mechanisms of heart failure treatments, we examined the effects of modulation of glucose handling on baroreflex-mediated sympathetic nerve activity and arterial pressure regulations in rats with chronic myocardial infarction (n = 9). Repeated 11-min step input sequences were used for an open-loop analysis of the carotid sinus baroreflex. An SGLT2 inhibitor, empagliflozin, was intravenously administered (10 mg/kg) after the second sequence. Neither the baroreflex neural nor peripheral arc significantly changed during the last observation period (seventh and eighth sequences) compared with the baseline period although urinary glucose excretion increased from near 0 (0.0089 ± 0.0011 mg min-1 kg-1) to 1.91 ± 0.25 mg min-1 kg-1. Hence, empagliflozin does not acutely modulate the baroreflex regulations of sympathetic nerve activity and arterial pressure in this rat model of chronic myocardial infarction.


Assuntos
Glucose , Infarto do Miocárdio , Animais , Ratos , Barorreflexo , Glucosídeos/farmacologia , Infarto do Miocárdio/tratamento farmacológico
19.
J Physiol Sci ; 73(1): 7, 2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37046217

RESUMO

Although suppression of sympathetic activity is suggested as one of the underlying mechanisms for the cardioprotective effects afforded by sodium-glucose cotransporter 2 (SGLT2) inhibitors, whether the modulation of glucose handling acutely affects sympathetic regulation of arterial pressure remains to be elucidated. In Goto-Kakizaki diabetic rats, we estimated the open-loop static characteristics of the carotid sinus baroreflex together with urine glucose excretion using repeated 11-min step input sequences. After the completion of the 2nd sequence, an SGLT2 inhibitor empagliflozin (10 mg kg-1) or vehicle solution was administered intravenously (n = 7 rats each). Empagliflozin did not significantly affect the baroreflex neural or peripheral arc, despite significantly increasing urine glucose excretion (from 0.365 ± 0.216 to 8.514 ± 0.864 mg·min-1·kg-1, P < 0.001) in the 7th and 8th sequences. The possible sympathoinhibitory effect of empagliflozin may be an indirect effect associated with chronic improvements in renal energy status and general disease conditions.


Assuntos
Barorreflexo , Diabetes Mellitus Experimental , Ratos , Animais , Barorreflexo/fisiologia , Diabetes Mellitus Experimental/tratamento farmacológico , Pressão Arterial , Glucose , Pressão Sanguínea/fisiologia
20.
Artigo em Inglês | MEDLINE | ID: mdl-38083332

RESUMO

Left ventricular end-systolic elastance Ees, as an index of cardiac contractility, can play a key role in continuous patient monitoring during cardiac treatment scenarios such as drug therapies. The clinical feasibility of Ees estimation remains challenging because most techniques have been built on left ventricular pressure and volume, which are difficult to measure or estimate in the regular ICU/CCU setting. The purpose of this paper is to propose and validate a novel approach to estimate Ees, which is independent of left ventricular pressure and volume. Our methods first derive an analytical representation of Ees as the inverse function of the gradient of the Frank-Starling Curve based on cardiac mechanics. Second, elucidating the mechanism of singularities in the inverse function, we derive multiple conditions in both end-systolic pressure-volume relationship (ESPVR) and end-diastolic pressure-volume relationship (EDPVR) parameters to avoid these singularities analytically. Third, we formulate a constrained nonlinear least squares problem to optimize both ESPVR and EDPVR parameters simultaneously to avoid singularities. The effectiveness of the proposed method in avoiding singularities was evaluated in an animal experiment. Compared to the conventional Ees estimation by linear regression, our proposed method reproduced in-vivo hemodynamics more accurately when simulating the estimated Ees variation during drug administration. Our method can be applied using the available data in the regular ICU/CCU setting. The improved clinical feasibility can support not only physicians' decision-making, including adjusting drug dosages in current clinical treatment, but also a closed-loop hemodynamic control system requiring accurate continuous Ees estimation.


Assuntos
Contração Miocárdica , Função Ventricular Esquerda , Animais , Humanos , Coração , Hemodinâmica , Ventrículos do Coração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA