Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Rapid Commun Mass Spectrom ; 29(2): 213-9, 2015 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-25641496

RESUMO

RATIONALE: Quantifying polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) with a conventional crystalline matrix generally suffers from poor sample-to-sample or shot-to-shot reproducibility. An ionic-liquid matrix has been demonstrated to mitigate these reproducibility issues by providing a homogeneous sample surface, which is useful for quantifying polymers. In the present study, we evaluated the use of an ionic liquid matrix, i.e., 1-methylimidazolium α-cyano-4-hydroxycinnamate (1-MeIm-CHCA), to quantify polyhexamethylene guanidine (PHMG) samples that impose a critical health hazard when inhaled in the form of droplets. METHODS: MALDI-TOF mass spectra were acquired for PHMG oligomers using a variety of ionic-liquid matrices including 1-MeIm-CHCA. Calibration curves were constructed by plotting the sum of the PHMG oligomer peak areas versus PHMG sample concentration with a variety of peptide internal standards. RESULTS: Compared with the conventional crystalline matrix, the 1-MeIm-CHCA ionic-liquid matrix had much better reproducibility (lower standard deviations). Furthermore, by using an internal peptide standard, good linear calibration plots could be obtained over a range of PMHG concentrations of at least 4 orders of magnitude. CONCLUSIONS: This study successfully demonstrated that PHMG samples can be quantitatively characterized by MALDI-TOFMS with an ionic-liquid matrix and an internal standard.


Assuntos
Guanidinas/análise , Guanidinas/química , Líquidos Iônicos/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Cinamatos/química , Imidazóis/química , Modelos Lineares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Rapid Commun Mass Spectrom ; 27(17): 1913-8, 2013 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-23939957

RESUMO

RATIONALE: Isosorbide is a promising biomass-derived molecule that can be used as a replacement for fossil resource-derived diol monomers used in polyester synthesis. Due to its increased use in sustainable development, it is useful to understand the tandem mass spectrometric (MS/MS) fragmentation pathways of the isosorbide-based copolymer as an aid to interpreting the MS/MS spectra of other isosorbide-containing copolymers. METHODS: Collision-activated dissociation (CAD) experiments were performed on the sodiated/protonated molecules, [(AB)(n)A+Na(or H)](+), n = 2-5, of isosorbide (A)-1,4-cyclohexanedicarboxylic acid (B) oligomers formed by ion-trap electrospray ionization (ESI). RESULTS: Product ions arose from cleavage of the bonds between isosorbide and 1,4-cyclohexanedicarboxylic acid. In the MS/MS spectra, f(n)'' product ions were most abundant, followed by e(n) ions. McLafferty rearrangement appeared to provide the most facile pathway to yield the abundant f(n)'' and e(n) ions. In addition, a(n), b(n)'', f(n)''u(n)'', and en (+) ions were observed. Inductive cleavage and ß-elimination were suggested to be the pathways involved in generating e(n)(+)- and e(n)/b(n)''-type ions, respectively. CONCLUSIONS: Based on the obtained CAD spectra, the alternating sequences of two copolymer building blocks, A and B, were unambiguously determined. The fragmentation pathways leading to the observed product ion types were also established.


Assuntos
Cicloexanos/química , Ácidos Dicarboxílicos/química , Isossorbida/química , Poliésteres/química , Espectrometria de Massas em Tandem/métodos , Estrutura Molecular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA