Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(13)2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-37447826

RESUMO

In this study, we propose an analytical approach based on the modified differential transform method to investigate the dynamic behavior of a plucking energy harvester. The harvester consists of a piezoelectric cantilever oscillator and a rotating plectrum. The analytical approach provides a closed-form solution that helps determine the starting and ending points of the contact phase between the piezoelectric cantilever and the plectrum. This analytical approach is valuable for simulating complex dynamic interferences in multiple or periodic plucking processes. To evaluate the effects of plucking speed and overlap length of the plectrum on single and periodic plucking, a series of simulations were carried out. The output voltage of the piezoelectric energy harvester increases as the overlap length of the plectrum increases. On the other hand, increasing the plucking speed tends to amplify the magnitude of the contact force while reducing the duration of the contact phase. Therefore, it is crucial to optimize the plucking speed to achieve the maximum linear impulse. For periodic plucking, successful synchronization between the motions of the piezoelectric energy harvester and the rotating plectrum must occur within a limited contact zone. Otherwise, dynamic interferences often cause the plectrum to fail to pluck the energy harvester exactly within the contact zone. Additionally, reducing the plucking speed of the plectrum and increasing the overlap length would be more advantageous for successful periodic-plucking energy harvesting.


Assuntos
Dinâmica não Linear , Extremidade Superior , Fenômenos Físicos , Movimento (Física)
2.
Opt Express ; 30(5): 8151-8164, 2022 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-35299562

RESUMO

In this study, we introduce a design for a near-eye, wearable display (HMD: head mounted display) that can automatically control the user's interpupillary distance (IPD). In addition, we demonstrate a test-bed module for the wearable AR display based on proposed design. Both the adjustment accuracy and the viewing effect through distance matching between the user's eyes are evaluated by the user's experience in actual wearing of the module. We demonstrate that the distance between the left and right eye pupils can be measured and adjusted using a set of IR camera sensors and a micro-actuator module that we proposed. A half-mirror unit to be mechanically controlled for each eye is designed to combine the image displayed from the projector and an image taken by the IR camera, leading to fine adjustment of the user's IPD. A set of images taken by the IR camera sensors is image-processed in real time to determine each pupil's position with high accuracy under infrared light illumination. Based on the measured information, a micro-actuator module we fabricated for the test bed can automatically adjust the binocular distance to fit each viewer's IPD. The maximum movement distance of each micro-actuator motor is ±10 mm with precision control of at least 0.5 mm. It takes about 18 seconds to calculate the user's IPD from two IR photographs and then to accurately adjust the actual binocular distance of the module that the participant wears. Using the demonstrated test bed, a total of 50 subjects participated to confirm the accuracy in the automatic IPD adjustment with an error of 0.25% as well as the improvement of the displayed image quality and 3D immersive experience.


Assuntos
Pupila , Dispositivos Eletrônicos Vestíveis , Humanos , Iluminação , Estimulação Luminosa , Pupila/fisiologia
3.
Sensors (Basel) ; 21(8)2021 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-33920097

RESUMO

In this study, the external load resistance of a magnetically coupled two-degree-of-freedom bistable energy harvester (2-DOF MCBEH) was optimized to maximize the harvested power output, considering the third-harmonic distortion in forced response. First, the nonlinear dynamic analysis was performed to investigate the characteristics of the large-amplitude interwell motions of the 2-DOF MCBEH. From the analysis results, it was found that the third-harmonic distortion occurs in the interwell motion of the 2-DOF MCBEH system due to the nonlinear magnetic coupling between the beams. Thus, in this study, the third-harmonic distortion was considered in the optimization process of the external load resistance of the 2-DOF MCBEH, which is different from the process of conventional impedance matching techniques suitable for linear systems. The optimal load resistances were estimated for harmonic and swept-sine excitations by using the proposed method, and all the results of the power outputs were in excellent agreements with the numerically optimized results. Furthermore, the associated power outputs were compared with the power outputs obtained by using the conventional impedance matching technique. The results of the power outputs are discussed in terms of the improvement in energy harvesting performance.

4.
Sensors (Basel) ; 21(5)2021 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-33807891

RESUMO

Because the oxides of nitrogen (NOx) cause detrimental effects on not only the environment but humans, developing a high-performance NO2 gas sensor is a crucial issue for real-time monitoring. To this end, metal oxide semiconductors have been employed for sensor materials. Because in general, semiconductor-type gas sensors require a high working temperature, photoactivation has emerged as an alternative method for realizing the sensor working at room temperature. In this regard, titanium dioxide (TiO2) is a promising material for its photocatalytic ability with ultraviolet (UV) photonic energy. However, TiO2-based sensors inevitably encounter a problem of recombination of photogenerated electron-hole pairs, which occurs in a short time. To address this challenge, in this study, TiO2 nanorods (NRs) and Pt nanoparticles (NPs) under a UV-LED were used as an NO2 gas sensor to utilize the Schottky barrier formed at the TiO2-Pt junction, thereby capturing the photoactivated electrons by Pt NPs. The separation between the electron-hole pairs might be further enhanced by plasmonic effects. In addition, it is reported that annealing TiO2 NRs can achieve noteworthy improvements in sensing performance. Elucidation of the performance enhancement is suggested with the investigation of the X-ray diffraction patterns, which implies that the crystallinity was improved by the annealing process.

5.
J Org Chem ; 83(1): 1-11, 2018 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-29207874

RESUMO

While N-hetereocycles have received significant attention in organic synthesis and other research fields, the chemistry of pyridazine, a six-membered aromatic ring with two adjacent nitrogen atoms, and its derivatives has been relatively little understood. This Synopsis describes recent progress made in the synthesis of pyridazine derivatives-particularly, pyridazin-3(2H)-ones-and their utility as efficient and recyclable functional group carriers for various important organic reactions.

6.
J Appl Biomech ; 33(6): 397-405, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28530482

RESUMO

The purpose of this study was to investigate the effect of load carriage on the kinematics and kinetics of the ankle and knee joints during uphill walking, including joint work, range of motion (ROM), and stance time. Fourteen males walked at a self-selected speed on an uphill (15°) slope wearing military boots and carrying a rifle in hand without a backpack (control condition) and with a backpack. The results showed that the stance time significantly decreased with backpack carriage (p < .05). The mediolateral impulse significantly increased with backpack carriage (p < .05). In the ankle joints, the inversion-eversion, and dorsi-plantar flexion ROM in the ankle joints increased with backpack carriage (p < .05). The greater dorsi-plantar flexion ROM with backpack carriage suggested 1 strategy for obtaining high plantar flexor power during uphill walking. The result of the increased mediolateral impulse and inversion-eversion ROM in the ankle joints indicated an increase in body instability caused by an elevated center of mass with backpack carriage during uphill walking. The decreased stance time indicated that an increase in walking speed could be a compensatory mechanism for reducing the instability of the body during uphill walking while carrying a heavy backpack.


Assuntos
Articulação do Tornozelo/fisiologia , Articulação do Joelho/fisiologia , Caminhada/fisiologia , Suporte de Carga/fisiologia , Fenômenos Biomecânicos , Humanos , Cinética , Masculino , Militares , Amplitude de Movimento Articular/fisiologia , Adulto Jovem
7.
Food Microbiol ; 53(Pt B): 182-91, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26678146

RESUMO

The purpose of this investigation was to identify and quantify the volatile chemical spoilage indexes (CSIs) for raw Atlantic salmon (Salmo salar) fillets stored under aerobic storage conditions at 4, 10 and 21 °C in relation to microbial and sensory shelf lives. The volatile organic compounds (VOCs) were analyzed with SPME-GC-MS technique. Through multivariate chemometric method, hierarchical cluster analysis (HCA) and Pearson's correlations, the CSIs: trimethylamine (TMA), ethanol (EtOH), 3-methyl-1-butanol (3Met-1But), acetoin and acetic acid (C2) were selected from the group of 28 detected VOCs. At the moment of microbiological shelf life established at total viable count (TVC) of 7.0 log CFU/g, the CSIs achieved levels of 11.5, 38.3, 0.3, 24.0 and 90.7 µg/g of salmon for TMA, EtOH, 3M-1But, acetoin and C2, respectively. Pseudomonas spp. was found as major specific spoilage organism (SSOs), suitable for shelf life prediction using modified Gompertz model at the cut-off level of 6.5 log CFU/g. H2S producing bacteria and Brochothrix thermosphacta were considered as important spoilage microorganisms; however, they were not suitable for shelf life estimation. Partial least square (PLS) regression revealed possible associations between microorganisms and synthetized VOCs, showing correlations between Pseudomonas spp. and 3Met-1But and aldehydes synthesis, lactic acid bacteria were linked with EtOH, C2 and esters, and B. thermosphacta with acetoin formation.


Assuntos
Bactérias/crescimento & desenvolvimento , Salmo salar/microbiologia , Alimentos Marinhos/análise , Compostos Orgânicos Voláteis/análise , Aerobiose , Animais , Bactérias/classificação , Bactérias/isolamento & purificação , Bactérias/metabolismo , Conservação de Alimentos , Armazenamento de Alimentos , Humanos , Alimentos Marinhos/microbiologia , Paladar , Compostos Orgânicos Voláteis/metabolismo
8.
J Acoust Soc Am ; 139(6): 3412, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27369168

RESUMO

This article reviews the development of metamaterials (MM), starting from Newton's discovery of the wave equation, and ends with a discussion of the need for a technical taxonomy (classification) of these materials, along with a better defined definition of metamaterials. It is intended to be a technical definition of metamaterials, based on a historical perspective. The evolution of MMs began with the discovery of the wave equation, traceable back to Newton's calculation of the speed of sound. The theory of sound evolved to include quasi-statics (Helmholtz) and the circuit equations of Kirchhoff's circuit laws, leading to the ultimate development of Maxwell's equations and the equation for the speed of light. Be it light, or sound, the speed of the wave-front travel defines the wavelength, and thus the quasi-static (QS) approximation. But there is much more at stake than QSs. Taxonomy requires a proper statement of the laws of physics, which includes at least the six basic network postulates: (P1) causality (non-causal/acausal), (P2) linearity (non-linear), (P3) real (complex) time response, (P4) passive (active), (P5) time-invariant (time varying), and (P6) reciprocal (non-reciprocal). These six postulates are extended to include MMs.

9.
Sensors (Basel) ; 17(1)2016 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-28035963

RESUMO

Smart grids have been introduced to replace conventional power distribution systems without real time monitoring for accommodating the future market penetration of plug-in electric vehicles (PEVs). When a large number of PEVs require simultaneous battery charging, charging coordination techniques have become one of the most critical factors to optimize the PEV charging performance and the conventional distribution system. In this case, considerable computational complexity of a central controller and exchange of real time information among PEVs may occur. To alleviate these problems, a novel threshold-based random charging (TBRC) operation for a decentralized charging system is proposed. Using PEV charging thresholds and random access rates, the PEVs themselves can participate in the charging requests. As PEVs with a high battery state do not transmit the charging requests to the central controller, the complexity of the central controller decreases due to the reduction of the charging requests. In addition, both the charging threshold and the random access rate are statistically calculated based on the average of supply power of the PEV charging system that do not require a real time update. By using the proposed TBRC with a tolerable PEV charging degradation, a 51% reduction of the PEV charging requests is achieved.

10.
Cancer ; 121(16): 2740-8, 2015 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-25965782

RESUMO

BACKGROUND: The purpose of the current study was to examine the effect of an oncologist's exercise recommendation with and without an exercise motivation package on the amount of exercise participation and quality of life (QOL) in survivors of breast and colorectal cancer. METHODS: A total of 162 survivors of early-stage breast and colorectal cancer who completed primary and adjuvant treatments were recruited for the current study. Participants were randomly assigned into 1 of 3 groups: 1) control (59 patients); 2) those receiving an oncologist's exercise recommendation (53 patients); and 3) those receiving an oncologist's exercise recommendation with an exercise motivation package (50 patients). At baseline and after 4 weeks, the level of exercise participation and QOL were assessed. RESULTS: Of the 162 participants, 130 (80.2%) completed the trial. Intention-to-treat analysis indicated that participants who received an oncologist's exercise recommendation with an exercise motivation package significantly increased their level of exercise participation in terms of minutes (47.57 added minutes per week; 95% confidence interval, 9.62-85.52 minutes [P =.022] vs control) and in Metabolic Equivalent of Task (MET)-hours per week (4.14 additional MET-hours per week; 95% confidence interval, 1.70-6.58 MET-hours [P =.004] vs control) compared with the control group. Participants who received only their oncologist's exercise recommendation did not increase their exercise participation level. Further analysis demonstrated that role functioning was significantly improved among participants who received an oncologist's exercise recommendation with an exercise motivation package. CONCLUSIONS: Providing an exercise motivation package in addition to the oncologist's exercise recommendation to increase the level of exercise among survivors of breast and colorectal cancer should be considered.


Assuntos
Neoplasias da Mama/psicologia , Neoplasias Colorretais/psicologia , Exercício Físico , Oncologia , Qualidade de Vida , Neoplasias da Mama/mortalidade , Neoplasias da Mama/patologia , Neoplasias Colorretais/mortalidade , Neoplasias Colorretais/patologia , Feminino , Humanos , Masculino , Motivação , Estadiamento de Neoplasias , Sobreviventes
11.
BMC Cancer ; 15: 249, 2015 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-25886264

RESUMO

BACKGROUND: The purpose of the present study was to examine 1) characteristics and attitudes of oncologists toward exercise and toward recommending exercise to their patients, 2) association among oncologists' own physical activity levels, exercise recommendations, and their attitudes toward recommending exercise. METHODS: A total of 167 oncologists participated in this survey study (41 surgeons, 78 medical oncologists, 25 radiation oncologists, and 21 others). Most oncologists included in the study treat more than one type of cancer, including colorectal, gastric, breast, lung, and liver cancer. To analyze the data, the one-way ANOVA, and t-test were used. All data were indicated for mean, SD, and proportions. RESULTS: Most oncologists agreed that exercise is beneficial (72.8%) and important (69.6%), but only 39.2% of them agreed that exercise is safe, and only 7.2% believed that cancer patients manage to exercise during cancer treatment. Forty-six percentage of the surveyed oncologists recommended exercise to their patients during the past month. The average amount of participation in physical activity by oncologists who participated in the study was 139.5 ± 120.3 min per week, and 11.4% of the study participants met the American College of Sports Medicine (ACSM) guidelines. Oncologists' own physical activity levels were associated with their attitudes toward recommending exercise. Belief in the benefits of exercise in the performance of daily tasks, improvement of mental health, and the attenuation of physical decline from treatment were the three most prevalent reasons why oncologists recommend exercise to their patients. Barriers to recommending exercise to patients included lack of time, unclear exercise recommendations, and the safety of patients. CONCLUSIONS: Oncologists have favorable attitudes toward exercise and toward recommending exercise to their patients during treatment. However, they also experience barriers to recommending exercise, including lack of time, unclear exercise guidelines for cancer patients, and concerns regarding the safety of exercise.


Assuntos
Atitude do Pessoal de Saúde , Terapia por Exercício , Neoplasias/terapia , Médicos , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Oncologia , Pessoa de Meia-Idade , Neoplasias/epidemiologia , República da Coreia , Inquéritos e Questionários
12.
Nanotechnology ; 26(37): 375501, 2015 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-26303117

RESUMO

Super-stretchable, skin-mountable, and ultra-soft strain sensors are presented by using carbon nanotube percolation network-silicone rubber nanocomposite thin films. The applicability of the strain sensors as epidermal electronic systems, in which mechanical compliance like human skin and high stretchability (ϵ > 100%) are required, has been explored. The sensitivity of the strain sensors can be tuned by the number density of the carbon nanotube percolation network. The strain sensors show excellent hysteresis performance at different strain levels and rates with high linearity and small drift. We found that the carbon nanotube-silicone rubber based strain sensors possess super-stretchability and high reliability for strains as large as 500%. The nanocomposite thin films exhibit high robustness and excellent resistance-strain dependency for over ~1380% mechanical strain. Finally, we performed skin motion detection by mounting the strain sensors on different parts of the body. The maximum induced strain by the bending of the finger, wrist, and elbow was measured to be ~ 42%, 45% and 63%, respectively.


Assuntos
Monitorização Fisiológica/instrumentação , Nanocompostos/química , Nanotecnologia/instrumentação , Nanotubos de Carbono/química , Poliésteres/química , Vestuário , Desenho de Equipamento , Humanos , Fenômenos Fisiológicos da Pele
13.
Sensors (Basel) ; 14(3): 4585-98, 2014 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-24608003

RESUMO

Sensor performance of a dielectric filled silicon bulk acoustic resonator type label-free biosensor is verified with biotin-streptavidin binding interactions as a model system. The mass sensor is a micromachined silicon square plate with a dielectric filled capacitive excitation mechanism. The resonance frequency of the biotin modified resonator decreased 315 ppm when exposed to streptavidin solution for 15 min with a concentration of 10(-7) M, corresponding to an added mass of 3.43 ng on the resonator surface. An additional control is added by exposing a bovine serum albumin (BSA)-covered device to streptavidin in the absence of the attached biotin. No resonance frequency shift was observed in the control experiment, which confirms the specificity of the detection. The sensor-to-sensor variability is also measured to be 4.3%. Consequently, the developed sensor can be used to observe in biotin-streptavidin interaction without the use of labelling or molecular tags. In addition, biosensor can be used in a variety of different immunoassay tests.


Assuntos
Acústica/instrumentação , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Biotina/metabolismo , Silício/química , Coloração e Rotulagem , Estreptavidina/metabolismo , Animais , Bovinos , Eletrodos , Eletrólitos/química , Proteínas Imobilizadas/metabolismo , Microscopia de Fluorescência , Peso Molecular , Ligação Proteica , Soluções
14.
Opt Express ; 21 Suppl 6: A970-6, 2013 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-24514938

RESUMO

We propose a dual-layer transparent Indium Tin Oxide (ITO) top electrode scheme and demonstrate the enhancement of the optical output power of GaN-based light emitting diodes (LEDs). The proposed dual-layer structure is composed of a layer with randomly distributed sphere-like nano-patterns obtained solely by a maskless wet etching process and a pre-annealed bottom layer to maintain current spreading of the electrode. It was observed that the surface morphologies and optoelectronic properties are dependent on etching duration. This electrode significantly improves the optical output power of GaN-based LEDs with an enhancement factor of 2.18 at 100 mA without degradation in electrical property when compared to a reference LED.

15.
Opt Express ; 21(15): 17931-40, 2013 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-23938665

RESUMO

We demonstrate a silicon-based optoelectronic integrated circuit (OEIC) for label-free bio/chemical sensing application. Such on-chip OEIC sensor system consists of optical grating couplers for vertical light coupling into silicon waveguides, a thermal-tunable microring as a tunable filter, an exposed microring as an optical label-free sensor, and a Ge photodetector for a direct electrical readout. Different from the conventional wavelength-scanning method, we adopt low-cost broadband ASE light source, together with the on-chip tunable filter to generate sliced light source. The effective refractive index change of the sensing microring induced by the sensing target is traced by scanning the supplied electrical power applied onto the tracing microring, and the detected electrical signal is read out by the Ge photodetector. For bulk refractive index sensing, we demonstrate using such OEIC sensing system with a sensitivity of ~15 mW/RIU and a detection limit of 3.9 µ-RIU, while for surface sensing of biotin-streptavidin, we obtain a surface mass sensitivity of S(m) = ~192 µW/ng·mm(-2) and a surface detection limit of 0.3 pg/mm(2). The presented OEIC sensing system is suitable for point-of-care applications.


Assuntos
Biopolímeros/análise , Condutometria/instrumentação , Eletrônica/instrumentação , Sistemas Microeletromecânicos/instrumentação , Refratometria/instrumentação , Semicondutores , Silício/química , Técnicas Biossensoriais/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Coloração e Rotulagem , Integração de Sistemas
16.
Chemistry ; 19(42): 14052-60, 2013 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-24108597

RESUMO

A series of three thiophene-naphthalene-based asymmetric oligomers-5-decyl-2,2':5',2'':5'',2'''-quaterthiophene (DtT), 5-decyl-5''-(naphthalen-2-yl)-2,2':5',2''-terthiophene (D3TN), and 5-(4-decylphenyl)-5'-(naphthalen-2-yl)-2,2'-bithiophene (DP2TN)-was synthesized by Suzuki cross-coupling reactions. The long alkyl side chains improved both the solubility of the oligomers in solvents and their tendency to self-assemble. UV/Vis absorption measurements suggested that DtT, D3TN, and DP2TN form H-type aggregates with a face-to-face packing structure. In addition, the three oligomers were found to adopt vertically aligned crystalline structures in films deposited on substrates, as revealed by grazing-incidence wide-angle X-ray scattering. These oligomers were used as the active layers of p-type organic field-effect transistors, and the resulting devices showed field-effect mobilities of 3.3×10(-3)  cm(2) V(-1) s(-1) for DtT, 1.6×10(-2)  cm(2) V(-1) s(-1) for D3TN, and 3.7×10(-2)  cm(2) V(-1) s(-1) for DP2TN. The differences in transistor performances were attributed to the degree of π overlap and the morphological differences determined by the molecular structures.

17.
Molecules ; 18(10): 12687-706, 2013 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-24129277

RESUMO

The geometric structures of Pd-complexes {Pd([9]aneB2A)L2 and Pd([9]aneBAB)L2 where A = P, S; B = N; L = PH3, P(CH3)3, Cl-}, their selective orbital interaction towards equatorial or axial (soft A…Pd) coordination of macrocyclic [9]aneB2A tridentate to PdL2, and electron density transfer from the electron-rich trans L-ligand to the low-lying unfilled a1g(5s)-orbital of PdL2 were investigated using B3P86/lanl2DZ for Pd and 6-311+G** for other atoms. The pentacoordinate endo-[Pd([9]aneB2A)(L-donor)2]2+ complex with an axial (soft A--Pd) quasi-bond was optimized for stability. The fifth (soft A--Pd) quasi-bond between the σ-donor of soft A and the partially unfilled a1g(5s)-orbital of PdL2 was formed. The pentacoordinate endo-Pd([9]aneB2A)(L-donor)2]2+ complex has been found to be more stable than the corresponding tetracoordinate endo-Pd complexes. Except for the endo-Pd pentacoordinates, the tetracoordinate Pd([9]aneBAB)L2 complex with one equatorial (soft A-Pd) bond is found to be more stable than the Pd([9]aneB2A)L2 isomer without the equatorial (A-Pd) bond. In particular, the geometric configuration of endo-[Pd([9]anePNP)(L-donor)2]2+ could not be optimized.


Assuntos
Complexos de Coordenação/química , Paládio/química , Quelantes/química , Simulação por Computador , Ligantes , Modelos Químicos , Modelos Moleculares , Conformação Molecular , Teoria Quântica
18.
Healthcare (Basel) ; 11(10)2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37239790

RESUMO

This review aimed to investigate the effects of exercise and exercise with joint mobilization on shoulder range of motion (ROM) and subjective symptom recovery in patients with adhesive capsulitis (AC). Related Studies published from 2000 to 2021 that were peer-reviewed and for which pre-and post-values could be calculated were extracted from PubMed, CINAHL, SPORTDiscus, and Web of Science. Nine studies met our inclusion criteria. As a result of calculating the standard mean difference (SMD) and 95% confidence intervals (CI), both exercise and exercise with joint mobilization showed a large effect on shoulder ROM and subjective outcomes. The combination showed a more significant effect than exercise alone on shoulder flexion (SMD = -1.59 [-2.34, -0.65]), extension (SMD = -1.47 [-2.05, -0.89]), internal rotation (SMD = -1.77 [-2.17, -1.36], external rotation (SMD = -2.18 [-2.92, -1.44]), and abduction ROM (SMD = -1.99 [CI -3.86, -0.12]). Patients who performed exercise alone showed a higher effect of improvement in subjective function (SMD = 3.15 [2.06, 4.24]) and pain (SMD = 4.13 [1.86, 6.41]). Based on these results, an AC rehabilitation exercise program should be developed by adjusting the amount of exercise and joint mobilization by identifying the patient's needs, subjective symptoms, and ROM.

19.
Sci Rep ; 13(1): 13150, 2023 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-37573439

RESUMO

Low-cost particulate matter (PM) sensors have been widely used following recent sensor-technology advancements; however, inherent limitations of low-cost monitors (LCMs), which operate based on light scattering without an air-conditioning function, still restrict their applicability. We propose a regional calibration of LCMs using a multivariate Tobit model with historical weather and air quality data to improve the accuracy of ambient air monitoring, which is highly dependent on meteorological conditions, local climate, and regional PM properties. Weather observations and PM2.5 (fine inhalable particles with diameters ≤ 2.5 µm) concentrations from two regions in Korea, Incheon and Jeju, and one in Singapore were used as training data to build a visibility-based calibration model. To validate the model, field measurements were conducted by an LCM in Jeju and Singapore, where R2 and the error after applying the model in Jeju improved (from 0.85 to 0.88) and reduced by 44% (from 8.4 to 4.7 µg m-3), respectively. The results demonstrated that regional calibration involving air temperature, relative humidity, and other local climate parameters can efficiently correct the bias of the sensor. Our findings suggest that the proposed post-processing using the Tobit model with regional weather and air quality data enhances the applicability of LCMs.

20.
Nat Commun ; 14(1): 8096, 2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38065944

RESUMO

Cellulose nanocrystals (CNCs) are intriguing as a matrix for plasmonic metasurfaces made of gold nanorods (GNRs) because of their distinctive properties, including renewability, biodegradability, non-toxicity, and low cost. Nevertheless, it is very difficult to precisely regulate the positioning and orientation of CNCs on the substrate in a consistent pattern. In this study, CNCs and GNRs, which exhibit tunable optical and anti-icing capabilities, are employed to manufacture a uniform plasmonic metasurface using a drop-casting technique. Two physical phenomena-(i) spontaneous and rapid self-dewetting and (ii) evaporation-induced self-assembly-are used to accomplish this. Additionally, we improve the CNC-GNR ink composition and determine the crucial coating parameters necessary to balance the two physical mechanisms in order to produce thin films without coffee rings. The final homogeneous CNC-GNR film has consistent annular ring patterns with plasmonic quadrant hues that are properly aligned, which enhances plasmonic photothermal effects. The CNC-GNR multi-array platform offers above-zero temperatures on a substrate that is subcooled below the freezing point. The current study presents a physicochemical approach for functional nanomaterial-based CNC control.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA