Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Magn Reson ; : 101055, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38971501

RESUMO

OBJECTIVES: To summarize the status of the SCMR Registry at 150,000 exams. BACKGROUND: Cardiovascular magnetic resonance (CMR) is increasingly utilized to evaluate expanding cardiovascular conditions. The SCMR Registry is a central repository for real-world clinical data to support cardiovascular research, including those relating to outcomes, quality improvement, and machine learning. The SCMR Registry is built on a regulatory-compliant, cloud-based infrastructure that houses searchable content and Digital Imaging and Communications in Medicine (DICOM) images. METHODS: The processes for data security, data submission, and research access are outlined. We interrogated the Registry and present a summary of its contents. RESULTS: Data were compiled from 154,458 CMR scans across 20 United States sites, containing 299,622,066 total images (~100 terabytes of storage). The human subjects had an average age of 58 years (range 1 month to >90 years old), were 44% female, 72% Caucasian, and had a mortality rate of 8%. The most common indication was cardiomyopathy (27%), and most frequently used current procedural terminology (CPT) code was 75561 (35%). Macrocyclic gadolinium-based contrast agents represented 89% of contrast utilization after 2015. Short-axis cines were performed in 99% of scans, short-axis LGE in 66%, and stress perfusion sequences in 30%. Mortality data demonstrated increased mortality in patients with left ventricular ejection fraction (LVEF) < 35%, the presence of wall motion abnormalities, stress perfusion defects, and infarct late gadolinium enhancement (LGE), compared to those without these markers. There were 456,678 patient-years of all-cause mortality follow-up, with a median follow-up time of 3.6 years. CONCLUSIONS: The vision of the SCMR Registry is to promote evidence-based utilization of CMR through a collaborative effort by providing a web mechanism for centers to securely upload de-identified data and images for research, education, and quality control. The Registry quantifies changing practice over time and supports large-scale real-world multicenter observational studies of prognostic utility. CONDENSED ABSTRACT: The SCMR Registry is a central regulatory-compliant cloud-based repository for real-world clinical data and DICOM images for multicenter cardiovascular research, including outcomes-based data. The Registry contains 299,622,066 DICOM images and 456,678 patient-years follow-up. Data compiled from 154,458 CMR scans across 20 US sites demonstrated cardiomyopathy as the most common indication and 89% macrocyclic gadolinium contrast utilization after 2015. There was an overall mortality rate of 8%, with higher rates in those with LVEF<35%, abnormal wall motion, ischemia presence, or infarct LGE. The Registry aims to promote evidence-based CMR utilization through a collaborative effort to positively impact cardiovascular outcomes.

2.
Radiology ; 306(2): e220122, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36125376

RESUMO

Background Left ventricular (LV) subclinical remodeling is associated with adverse outcomes and indicates mechanisms of disease development. Standard metrics such as LV mass and volumes may not capture the full range of remodeling. Purpose To quantify the relationship between LV three-dimensional shape at MRI and incident cardiovascular events over 10 years. Materials and Methods In this retrospective study, 5098 participants from the Multi-Ethnic Study of Atherosclerosis who were free of clinical cardiovascular disease underwent cardiac MRI from 2000 to 2002. LV shape models were automatically generated using a machine learning workflow. Event-specific remodeling signatures were computed using partial least squares regression, and random survival forests were used to determine which features were most associated with incident heart failure (HF), coronary heart disease (CHD), and cardiovascular disease (CVD) events over a 10-year follow-up period. The discrimination improvement of adding LV shape to traditional cardiovascular risk factors, coronary artery calcium scores, and N-terminal pro-brain natriuretic peptide levels was assessed using the index of prediction accuracy and time-dependent area under the receiver operating characteristic curve (AUC). Kaplan-Meier survival curves were used to illustrate the ability of remodeling signatures to predict the end points. Results Overall, 4618 participants had sufficient three-dimensional MRI information to generate patient-specific LV models (mean age, 60.6 years ± 9.9 [SD]; 2540 women). Among these participants, 147 had HF, 317 had CHD, and 455 had CVD events. The addition of LV remodeling signatures to traditional cardiovascular risk factors improved the mean AUC for 10-year survival prediction and achieved better performance than LV mass and volumes; HF (AUC, 0.83 ± 0.01 and 0.81 ± 0.01, respectively; P < .05), CHD (AUC, 0.77 ± 0.01 and 0.75 ± 0.01, respectively; P < .05), and CVD (AUC, 0.78 ± 0.0 and 0.76 ± 0.0, respectively; P < .05). Kaplan-Meier analysis demonstrated that participants with high-risk HF remodeling signatures had a 10-year survival rate of 56% compared with 95% for those with low-risk scores. Conclusion Left ventricular event-specific remodeling signatures were more predictive of heart failure, coronary heart disease, and cardiovascular disease events over 10 years than standard mass and volume measures and enable an automatic personalized medicine approach to tracking remodeling. © RSNA, 2022 Online supplemental material is available for this article.


Assuntos
Aterosclerose , Doenças Cardiovasculares , Doença das Coronárias , Insuficiência Cardíaca , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Estudos Prospectivos , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética/métodos , Fatores de Risco
3.
J Cardiovasc Magn Reson ; 25(1): 16, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36991474

RESUMO

BACKGROUND: Cine Displacement Encoding with Stimulated Echoes (DENSE) facilitates the quantification of myocardial deformation, by encoding tissue displacements in the cardiovascular magnetic resonance (CMR) image phase, from which myocardial strain can be estimated with high accuracy and reproducibility. Current methods for analyzing DENSE images still heavily rely on user input, making this process time-consuming and subject to inter-observer variability. The present study sought to develop a spatio-temporal deep learning model for segmentation of the left-ventricular (LV) myocardium, as spatial networks often fail due to contrast-related properties of DENSE images. METHODS: 2D + time nnU-Net-based models have been trained to segment the LV myocardium from DENSE magnitude data in short- and long-axis images. A dataset of 360 short-axis and 124 long-axis slices was used to train the networks, from a combination of healthy subjects and patients with various conditions (hypertrophic and dilated cardiomyopathy, myocardial infarction, myocarditis). Segmentation performance was evaluated using ground-truth manual labels, and a strain analysis using conventional methods was performed to assess strain agreement with manual segmentation. Additional validation was performed using an externally acquired dataset to compare the inter- and intra-scanner reproducibility with respect to conventional methods. RESULTS: Spatio-temporal models gave consistent segmentation performance throughout the cine sequence, while 2D architectures often failed to segment end-diastolic frames due to the limited blood-to-myocardium contrast. Our models achieved a DICE score of 0.83 ± 0.05 and a Hausdorff distance of 4.0 ± 1.1 mm for short-axis segmentation, and 0.82 ± 0.03 and 7.9 ± 3.9 mm respectively for long-axis segmentations. Strain measurements obtained from automatically estimated myocardial contours showed good to excellent agreement with manual pipelines, and remained within the limits of inter-user variability estimated in previous studies. CONCLUSION: Spatio-temporal deep learning shows increased robustness for the segmentation of cine DENSE images. It provides excellent agreement with manual segmentation for strain extraction. Deep learning will facilitate the analysis of DENSE data, bringing it one step closer to clinical routine.


Assuntos
Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Humanos , Reprodutibilidade dos Testes , Imagem Cinética por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Miocárdio/patologia , Redes Neurais de Computação , Espectroscopia de Ressonância Magnética
4.
J Cardiovasc Magn Reson ; 25(1): 80, 2023 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-38124106

RESUMO

BACKGROUND: Quantification of three-dimensional (3D) cardiac anatomy is important for the evaluation of cardiovascular diseases. Changes in anatomy are indicative of remodeling processes as the heart tissue adapts to disease. Although robust segmentation methods exist for computed tomography angiography (CTA), few methods exist for whole-heart cardiovascular magnetic resonance angiograms (CMRA) which are more challenging due to variable contrast, lower signal to noise ratio and a limited amount of labeled data. METHODS: Two state-of-the-art unsupervised generative deep learning domain adaptation architectures, generative adversarial networks and variational auto-encoders, were applied to 3D whole heart segmentation of both conventional (n = 20) and high-resolution (n = 45) CMRA (target) images, given segmented CTA (source) images for training. An additional supervised loss function was implemented to improve performance given 10%, 20% and 30% segmented CMRA cases. A fully supervised nn-UNet trained on the given CMRA segmentations was used as the benchmark. RESULTS: The addition of a small number of segmented CMRA training cases substantially improved performance in both generative architectures in both standard and high-resolution datasets. Compared with the nn-UNet benchmark, the generative methods showed substantially better performance in the case of limited labelled cases. On the standard CMRA dataset, an average 12% (adversarial method) and 10% (variational method) improvement in Dice score was obtained. CONCLUSIONS: Unsupervised domain-adaptation methods for CMRA segmentation can be boosted by the addition of a small number of supervised target training cases. When only few labelled cases are available, semi-supervised generative modelling is superior to supervised methods.


Assuntos
Doenças Cardiovasculares , Sistema Cardiovascular , Humanos , Angiografia por Ressonância Magnética , Valor Preditivo dos Testes , Coração , Processamento de Imagem Assistida por Computador
5.
J Cardiovasc Magn Reson ; 25(1): 15, 2023 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-36849960

RESUMO

BACKGROUND: Cardiac shape modeling is a useful computational tool that has provided quantitative insights into the mechanisms underlying dysfunction in heart disease. The manual input and time required to make cardiac shape models, however, limits their clinical utility. Here we present an end-to-end pipeline that uses deep learning for automated view classification, slice selection, phase selection, anatomical landmark localization, and myocardial image segmentation for the automated generation of three-dimensional, biventricular shape models. With this approach, we aim to make cardiac shape modeling a more robust and broadly applicable tool that has processing times consistent with clinical workflows. METHODS: Cardiovascular magnetic resonance (CMR) images from a cohort of 123 patients with repaired tetralogy of Fallot (rTOF) from two internal sites were used to train and validate each step in the automated pipeline. The complete automated pipeline was tested using CMR images from a cohort of 12 rTOF patients from an internal site and 18 rTOF patients from an external site. Manually and automatically generated shape models from the test set were compared using Euclidean projection distances, global ventricular measurements, and atlas-based shape mode scores. RESULTS: The mean absolute error (MAE) between manually and automatically generated shape models in the test set was similar to the voxel resolution of the original CMR images for end-diastolic models (MAE = 1.9 ± 0.5 mm) and end-systolic models (MAE = 2.1 ± 0.7 mm). Global ventricular measurements computed from automated models were in good agreement with those computed from manual models. The average mean absolute difference in shape mode Z-score between manually and automatically generated models was 0.5 standard deviations for the first 20 modes of a reference statistical shape atlas. CONCLUSIONS: Using deep learning, accurate three-dimensional, biventricular shape models can be reliably created. This fully automated end-to-end approach dramatically reduces the manual input required to create shape models, thereby enabling the rapid analysis of large-scale datasets and the potential to deploy statistical atlas-based analyses in point-of-care clinical settings. Training data and networks are available from cardiacatlas.org.


Assuntos
Aprendizado Profundo , Tetralogia de Fallot , Humanos , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Valor Preditivo dos Testes , Ventrículos do Coração , Diástole
6.
Am J Physiol Heart Circ Physiol ; 323(2): H257-H275, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35657613

RESUMO

The complex and highly organized structural arrangement of some five billion cardiomyocytes directs the coordinated electrical activity and mechanical contraction of the human heart. The characteristic transmural change in cardiomyocyte orientation underlies base-to-apex shortening, circumferential shortening, and left ventricular torsion during contraction. Individual cardiomyocytes shorten ∼15% and increase in diameter ∼8%. Remarkably, however, the left ventricular wall thickens by up to 30-40%. To accommodate this, the myocardium must undergo significant structural rearrangement during contraction. At the mesoscale, collections of cardiomyocytes are organized into sheetlets, and sheetlet shear is the fundamental mechanism of rearrangement that produces wall thickening. Herein, we review the histological and physiological studies of myocardial mesostructure that have established the sheetlet shear model of wall thickening. Recent developments in tissue clearing techniques allow for imaging of whole hearts at the cellular scale, whereas magnetic resonance imaging (MRI) and computed tomography (CT) can image the myocardium at the mesoscale (100 µm to 1 mm) to resolve cardiomyocyte orientation and organization. Through histology, cardiac diffusion tensor imaging (DTI), and other modalities, mesostructural sheetlets have been confirmed in both animal and human hearts. Recent in vivo cardiac DTI methods have measured reorientation of sheetlets during the cardiac cycle. We also examine the role of pathological cardiac remodeling on sheetlet organization and reorientation, and the impact this has on ventricular function and dysfunction. We also review the unresolved mesostructural questions and challenges that may direct future work in the field.


Assuntos
Imagem de Tensor de Difusão , Miocárdio , Animais , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Ventrículos do Coração , Contração Miocárdica , Miocárdio/patologia , Miócitos Cardíacos
7.
Eur Radiol ; 32(9): 5907-5920, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35368227

RESUMO

OBJECTIVES: To develop an image-based automatic deep learning method to classify cardiac MR images by sequence type and imaging plane for improved clinical post-processing efficiency. METHODS: Multivendor cardiac MRI studies were retrospectively collected from 4 centres and 3 vendors. A two-head convolutional neural network ('CardiSort') was trained to classify 35 sequences by imaging sequence (n = 17) and plane (n = 10). Single vendor training (SVT) on single-centre images (n = 234 patients) and multivendor training (MVT) with multicentre images (n = 434 patients, 3 centres) were performed. Model accuracy and F1 scores on a hold-out test set were calculated, with ground truth labels by an expert radiologist. External validation of MVT (MVTexternal) was performed on data from 3 previously unseen magnet systems from 2 vendors (n = 80 patients). RESULTS: Model sequence/plane/overall accuracy and F1-scores were 85.2%/93.2%/81.8% and 0.82 for SVT and 96.1%/97.9%/94.3% and 0.94 MVT on the hold-out test set. MVTexternal yielded sequence/plane/combined accuracy and F1-scores of 92.7%/93.0%/86.6% and 0.86. There was high accuracy for common sequences and conventional cardiac planes. Poor accuracy was observed for underrepresented classes and sequences where there was greater variability in acquisition parameters across centres, such as perfusion imaging. CONCLUSIONS: A deep learning network was developed on multivendor data to classify MRI studies into component sequences and planes, with external validation. With refinement, it has potential to improve workflow by enabling automated sequence selection, an important first step in completely automated post-processing pipelines. KEY POINTS: • Deep learning can be applied for consistent and efficient classification of cardiac MR image types. • A multicentre, multivendor study using a deep learning algorithm (CardiSort) showed high classification accuracy on a hold-out test set with good generalisation to images from previously unseen magnet systems. • CardiSort has potential to improve clinical workflows, as a vital first step in developing fully automated post-processing pipelines.


Assuntos
Imageamento por Ressonância Magnética , Redes Neurais de Computação , Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
8.
J Cardiovasc Magn Reson ; 24(1): 46, 2022 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-35922806

RESUMO

BACKGROUND: Maladaptive remodelling mechanisms occur in patients with repaired tetralogy of Fallot (rToF) resulting in a cycle of metabolic and structural changes. Biventricular shape analysis may indicate mechanisms associated with adverse events independent of pulmonary regurgitant volume index (PRVI). We aimed to determine novel remodelling patterns associated with adverse events in patients with rToF using shape and function analysis. METHODS: Biventricular shape and function were studied in 192 patients with rToF (median time from TOF repair to baseline evaluation 13.5 years). Linear discriminant analysis (LDA) and principal component analysis (PCA) were used to identify shape differences between patients with and without adverse events. Adverse events included death, arrhythmias, and cardiac arrest with median follow-up of 10 years. RESULTS: LDA and PCA showed that shape characteristics pertaining to adverse events included a more circular left ventricle (LV) (decreased eccentricity), dilated (increased sphericity) LV base, increased right ventricular (RV) apical sphericity, and decreased RV basal sphericity. Multivariate LDA showed that the optimal discriminative model included only RV apical ejection fraction and one PCA mode associated with a more circular and dilated LV base (AUC = 0.77). PRVI did not add value, and shape changes associated with increased PRVI were not predictive of adverse outcomes. CONCLUSION: Pathological remodelling patterns in patients with rToF are significantly associated with adverse events, independent of PRVI. Mechanisms related to incident events include LV basal dilation with a reduced RV apical ejection fraction.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Humanos , Valor Preditivo dos Testes , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Tetralogia de Fallot/complicações , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Função Ventricular Direita
9.
Magn Reson Med ; 86(6): 3096-3110, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34431550

RESUMO

PURPOSE: Hemodynamic alterations are indicative of cerebrovascular disease. However, the narrow and tortuous cerebrovasculature complicates image-based assessment, especially when quantifying relative pressure. Here, we present a systematic evaluation of image-based cerebrovascular relative pressure mapping, investigating the accuracy of the routinely used reduced Bernoulli (RB), the extended unsteady Bernoulli (UB), and the full-field virtual work-energy relative pressure ( ν WERP) method. METHODS: Patient-specific in silico models were used to generate synthetic cerebrovascular 4D Flow MRI, with RB, UB, and ν WERP performance quantified as a function of spatiotemporal sampling and image noise. Cerebrovascular relative pressures were also derived in 4D Flow MRI from healthy volunteers ( n=8 ), acquired at two spatial resolutions (dx = 1.1 and 0.8 mm). RESULTS: The in silico analysis indicate that accurate relative pressure estimations are inherently coupled to spatial sampling: at dx = 1.0 mm high errors are reported for all methods; at dx = 0.5 mm ν WERP recovers relative pressures at a mean error of 0.02 ± 0.25 mm Hg, while errors remain higher for RB and UB (mean error of -2.18 ± 1.91 and -2.18 ± 1.87 mm Hg, respectively). The dependence on spatial sampling is also indicated in vivo, albeit with higher correlative dependence between resolutions using ν WERP (k = 0.64, R2 = 0.81 for dx = 1.1 vs. 0.8 mm) than with RB or UB (k = 0.04, R2 = 0.03, and k = 0.07, R2 = 0.07, respectively). CONCLUSION: Image-based full-field methods such as ν WERP enable cerebrovascular relative pressure mapping; however, accuracy is directly dependent on utilized spatial resolution.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Voluntários Saudáveis , Hemodinâmica , Humanos
10.
J Cardiovasc Magn Reson ; 23(1): 59, 2021 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-34011372

RESUMO

BACKGROUND: Patients with repaired Tetralogy of Fallot (rTOF) often develop cardiovascular dysfunction and require regular imaging to evaluate deterioration and time interventions such as pulmonary valve replacement. Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) enables detailed assessment of flow characteristics in all chambers and great vessels. We performed a systematic review of intra-cardiac 4D flow applications in rTOF patients, to examine clinical utility and highlight optimal methods for evaluating rTOF patients. METHODS: A comprehensive literature search was undertaken in March 2020 on Google Scholar and Scopus. A modified version of the Critical Appraisal Skills Programme (CASP) tool was used to assess and score the applicability of each study. Important clinical outcomes were assessed including similarities and differences. RESULTS: Of the 635 articles identified, 26 studies met eligibility for systematic review. None of these were below 59% applicability on the modified CASP score. Studies could be broadly classified into four groups: (i) pilot studies, (ii) development of new acquisition methods, (iii) validation and (vi) identification of novel flow features. Quantitative comparison with other modalities included 2D phase contrast CMR (13 studies) and echocardiography (4 studies). The 4D flow study applications included stroke volume (18/26;69%), regurgitant fraction (16/26;62%), relative branch pulmonary artery flow(4/26;15%), systolic peak velocity (9/26;35%), systemic/pulmonary total flow ratio (6/26;23%), end diastolic and end systolic volume (5/26;19%), kinetic energy (5/26;19%) and vorticity (2/26;8%). CONCLUSIONS: 4D flow CMR shows potential in rTOF assessment, particularly in retrospective valve tracking for flow evaluation, velocity profiling, intra-cardiac kinetic energy quantification, and vortex visualization. Protocols should be targeted to pathology. Prospective, randomized, multi-centered studies are required to validate these new characteristics and establish their clinical use.


Assuntos
Tetralogia de Fallot , Ventrículos do Coração , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Estudos Prospectivos , Estudos Retrospectivos , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia
11.
J Cardiovasc Magn Reson ; 23(1): 105, 2021 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-34615541

RESUMO

BACKGROUND: Relationships between right ventricular (RV) and left ventricular (LV) shape and function may be useful in determining optimal timing for pulmonary valve replacement in patients with repaired tetralogy of Fallot (rTOF). However, these are multivariate and difficult to quantify. We aimed to quantify variations in biventricular shape associated with pulmonary regurgitant volume (PRV) in rTOF using a biventricular atlas. METHODS: In this cross-sectional retrospective study, a biventricular shape model was customized to cardiovascular magnetic resonance (CMR) images from 88 rTOF patients (median age 16, inter-quartile range 11.8-24.3 years). Morphometric scores quantifying biventricular shape at end-diastole and end-systole were computed using principal component analysis. Multivariate linear regression was used to quantify biventricular shape associations with PRV, corrected for age, sex, height, and weight. Regional associations were confirmed by univariate correlations with distances and angles computed from the models, as well as global systolic strains computed from changes in arc length from end-diastole to end-systole. RESULTS: PRV was significantly associated with 5 biventricular morphometric scores, independent of covariates, and accounted for 12.3% of total shape variation (p < 0.05). Increasing PRV was associated with RV dilation and basal bulging, in conjunction with decreased LV septal-lateral dimension (LV flattening) and systolic septal motion towards the RV (all p < 0.05). Increased global RV radial, longitudinal, circumferential and LV radial systolic strains were significantly associated with increased PRV (all p < 0.05). CONCLUSION: A biventricular atlas of rTOF patients quantified multivariate relationships between left-right ventricular morphometry and wall motion with pulmonary regurgitation. Regional RV dilation, LV reduction, LV septal-lateral flattening and increased RV strain were all associated with increased pulmonary regurgitant volume. Morphometric scores provide simple metrics linking mechanisms for structural and functional alteration with important clinical indices.


Assuntos
Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Adolescente , Adulto , Criança , Estudos Transversais , Humanos , Valor Preditivo dos Testes , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Estudos Retrospectivos , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Função Ventricular Direita , Adulto Jovem
12.
J Cardiovasc Magn Reson ; 22(1): 69, 2020 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-32951605

RESUMO

PURPOSE: Common types of congenital heart disease exhibit a variety of structural and functional variations which may be accompanied by changes in the myocardial microstructure. We aimed to compare myocardial architecture from magnetic resonance diffusion tensor imaging (DTI) in preserved pathology specimens. MATERIALS AND METHODS: Pathology specimens (n = 24) formalin-fixed for 40.8 ± 7.9 years comprised tetralogy of Fallot (TOF, n = 10), dextro-transposition of great arteries (D-TGA, n = 8) five with ventricular septal defect (VSD), systemic right ventricle (n = 4), situs inversus totalis (SIT, n = 1) and levo-TGA (L-TGA, n = 1). Specimens were imaged using a custom spin-echo sequence and segmented automatically according to tissue volume fraction. In each specimen T1, T2, fractional anisotropy, mean diffusivity, helix angle (HA) and sheet angle (E2A) were quantified. Pathologies were compared according to their HA gradient, HA asymmetry and E2A mean value in each myocardial segment (anterior, posterior, septal and lateral walls). RESULTS: TOF and D-TGA with VSD had decreased helix angle gradient by - 0.34°/% and remained symmetric in the septum in comparison to D-TGA without VSD. Helix angle range was decreased by 45°. It was associated with a decreased HA gradient in the right ventricular (RV) wall, i.e. predominant circumferential myocytes. The sheet angle in the septum of TOF was opposing those of the left ventricular (LV) free wall. Univentricular systemic RV had the lowest HA gradient (- 0.43°/%) and the highest HA asymmetry (75%). HA in SIT was linear, asymmetric, and reversed with a sign change at about 70% of the depth at mid-ventricle. In L-TGA with VSD, HA was asymmetric (90%) and its gradients were decreased in the septum, anterior and lateral wall. CONCLUSION: The organization of the myocytes as determined by DTI differs between TOF, D-TGA, L-TGA, systemic RV and SIT specimens. These differences in cardiac structure may further enlighten our understanding of cardiac function in these diverse congenital heart diseases.


Assuntos
Imagem de Difusão por Ressonância Magnética , Ventrículos do Coração/diagnóstico por imagem , Miocárdio/patologia , Tetralogia de Fallot/diagnóstico por imagem , Adulto , Feminino , Ventrículos do Coração/anormalidades , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Tetralogia de Fallot/patologia , Tetralogia de Fallot/fisiopatologia , Função Ventricular Esquerda , Função Ventricular Direita
13.
Biophys J ; 117(12): 2273-2286, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31653449

RESUMO

Heart failure (HF) is one of the leading causes of death worldwide. HF is associated with substantial microstructural remodeling, which is linked to changes in left ventricular geometry and impaired cardiac function. The role of myocardial remodeling in altering the mechanics of failing hearts remains unclear. Structurally based constitutive modeling provides an approach to improve understanding of the relationship between biomechanical function and tissue organization in cardiac muscle during HF. In this study, we used cardiac magnetic resonance imaging and extended-volume confocal microscopy to quantify the remodeling of left ventricular geometry and myocardial microstructure of healthy and spontaneously hypertensive rat hearts at the ages of 12 and 24 months. Passive cardiac mechanical function was characterized using left ventricular pressure-volume compliance measurements. We have developed a, to our knowledge, new structurally based biomechanical constitutive equation built on parameters quantified directly from collagen distributions observed in confocal images of the myocardium. Three-dimensional left ventricular finite element models were constructed from subject-specific in vivo magnetic resonance imaging data. The structurally based constitutive equation was integrated into geometrically subject-specific finite element models of the hearts and used to investigate the underlying mechanisms of ventricular dysfunction during HF. Using a single pair of material parameters for all hearts, we were able to produce compliance curves that reproduced all of the experimental compliance measurements. The value of this study is not limited to reproducing the mechanical behavior of healthy and diseased hearts, but it also provides important insights into the structure-function relationship of diseased myocardium that will help pave the way toward more effective treatments for HF.


Assuntos
Insuficiência Cardíaca/patologia , Modelos Cardiovasculares , Animais , Progressão da Doença , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Miocárdio/patologia , Pressão , Ratos , Disfunção Ventricular Esquerda/complicações
14.
J Cardiovasc Magn Reson ; 21(1): 61, 2019 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-31590664

RESUMO

Machine learning (ML) is making a dramatic impact on cardiovascular magnetic resonance (CMR) in many ways. This review seeks to highlight the major areas in CMR where ML, and deep learning in particular, can assist clinicians and engineers in improving imaging efficiency, quality, image analysis and interpretation, as well as patient evaluation. We discuss recent developments in the field of ML relevant to CMR in the areas of image acquisition & reconstruction, image analysis, diagnostic evaluation and derivation of prognostic information. To date, the main impact of ML in CMR has been to significantly reduce the time required for image segmentation and analysis. Accurate and reproducible fully automated quantification of left and right ventricular mass and volume is now available in commercial products. Active research areas include reduction of image acquisition and reconstruction time, improving spatial and temporal resolution, and analysis of perfusion and myocardial mapping. Although large cohort studies are providing valuable data sets for ML training, care must be taken in extending applications to specific patient groups. Since ML algorithms can fail in unpredictable ways, it is important to mitigate this by open source publication of computational processes and datasets. Furthermore, controlled trials are needed to evaluate methods across multiple centers and patient groups.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Diagnóstico por Computador , Interpretação de Imagem Assistida por Computador , Aprendizado de Máquina , Imagem Cinética por Ressonância Magnética , Imagem de Perfusão do Miocárdio , Doenças Cardiovasculares/patologia , Doenças Cardiovasculares/fisiopatologia , Circulação Coronária , Aprendizado Profundo , Humanos , Miocárdio/patologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Aprendizado de Máquina Supervisionado , Aprendizado de Máquina não Supervisionado
15.
J Cardiovasc Magn Reson ; 21(1): 41, 2019 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-31315625

RESUMO

BACKGROUND: The associations between cardiovascular disease (CVD) risk factors and the biventricular geometry of the right ventricle (RV) and left ventricle (LV) have been difficult to assess, due to subtle and complex shape changes. We sought to quantify reference RV morphology as well as biventricular variations associated with common cardiovascular risk factors. METHODS: A biventricular shape atlas was automatically constructed using contours and landmarks from 4329 UK Biobank cardiovascular magnetic resonance (CMR) studies. A subdivision surface geometric mesh was customized to the contours using a diffeomorphic registration algorithm, with automatic correction of slice shifts due to differences in breath-hold position. A reference sub-cohort was identified consisting of 630 participants with no CVD risk factors. Morphometric scores were computed using linear regression to quantify shape variations associated with four risk factors (high cholesterol, high blood pressure, obesity and smoking) and three disease factors (diabetes, previous myocardial infarction and angina). RESULTS: The atlas construction led to an accurate representation of 3D shapes at end-diastole and end-systole, with acceptable fitting errors between surfaces and contours (average error less than 1.5 mm). Atlas shape features had stronger associations than traditional mass and volume measures for all factors (p < 0.005 for each). High blood pressure was associated with outward displacement of the LV free walls, but inward displacement of the RV free wall and thickening of the septum. Smoking was associated with a rounder RV with inward displacement of the RV free wall and increased relative wall thickness. CONCLUSION: Morphometric relationships between biventricular shape and cardiovascular risk factors in a large cohort show complex interactions between RV and LV morphology. These can be quantified by z-scores, which can be used to study the morphological correlates of disease.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/normas , Função Ventricular Esquerda , Função Ventricular Direita , Remodelação Ventricular , Idoso , Pontos de Referência Anatômicos , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/fisiopatologia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Valores de Referência , Reprodutibilidade dos Testes , Fatores de Risco , Reino Unido/epidemiologia
16.
NMR Biomed ; 31(10): e3848, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29106765

RESUMO

Although magnetic resonance elastography (MRE) has been used to estimate isotropic stiffness in the heart, myocardium is known to have anisotropic properties. This study investigated the determinability of global transversely isotropic material parameters using MRE and finite-element modeling (FEM). A FEM-based material parameter identification method, using a displacement-matching objective function, was evaluated in a gel phantom and simulations of a left ventricular (LV) geometry with a histology-derived fiber field. Material parameter estimation was performed in the presence of Gaussian noise. Parameter sweeps were analyzed and characteristics of the Hessian matrix at the optimal solution were used to evaluate the determinability of each constitutive parameter. Four out of five material stiffness parameters (Young's modulii E1 and E3 , shear modulus G13 and damping coefficient s), which describe a transversely isotropic linear elastic material, were well determined from the MRE displacement field using an iterative FEM inversion method. However, the remaining parameter, Poisson's ratio, was less identifiable. In conclusion, Young's modulii, shear modulii and damping can theoretically be well determined from MRE data, but Poisson's ratio is not as well determined and could be set to a reasonable value for biological tissue (close to 0.5).


Assuntos
Técnicas de Imagem por Elasticidade , Imageamento por Ressonância Magnética , Algoritmos , Anisotropia , Simulação por Computador , Imagens de Fantasmas
17.
J Magn Reson Imaging ; 47(3): 787-797, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28722247

RESUMO

PURPOSE: To provide regional strain and ventricular volume from a single acquisition, using subtly tagged steady-state free precession (SubTag SSFP) feature tracking. MATERIALS AND METHODS: The effects on regional strain of tag strength in gradient recalled echo (GRE) tagging, flip angle in untagged balanced SSFP, and both in SubTag SSFP were examined in the mid left ventricle of 15 healthy volunteers at 3T. Optimal parameters were determined from varying both tag strength and SSFP flip angle using full tag saturation GRE as the reference standard. SubTag SSFP was acquired in 15 additional healthy volunteers for whole-heart volume and strain assessment using the optimized parameters. Values measured by two image analysts were compared to clinical reference standards from untagged SSFP (volumes) and GRE tagging (strains). RESULTS: Regional strain accuracy was maintained with decreasing total tagging flip angle (ß); less than 3% differences for ß ≥ 26°. For untagged SSFP flip angle (α), whole-wall strain differences became statistically significant when α < 40°. A SubTag SSFP acquisition with α = 40° and ß = 46° showed the best combination of tagging strength, blood-myocardial contrast, and tag persistence at end-systole for regional strain estimation. SubTag SSFP also showed excellent agreement with untagged SSFP for volumetrics (percent difference: end-diastolic volume = 0.6%, end-systolic volume = 0.4%, stroke volume = 1.2%, ejection fraction = 0.6%, mass = 1.1%). CONCLUSION: Feature tracking for regional myocardial strain assessment is dependent on image features, mainly the tag strength, persistence, and image contrast. SubTag SSFP balances these criteria to provide accurate regional strain and volumetric assessment in a single acquisition. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2018;47:787-797.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Função Ventricular Esquerda/fisiologia , Adulto , Feminino , Humanos , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Volume Sistólico/fisiologia
18.
J Cardiovasc Magn Reson ; 19(1): 23, 2017 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-28187739

RESUMO

BACKGROUND: With multifaceted imaging capabilities, cardiovascular magnetic resonance (CMR) is playing a progressively increasing role in the management of various cardiac conditions. A global registry that harmonizes data from international centers, with participation policies that aim to be open and inclusive of all CMR programs, can support future evidence-based growth in CMR. METHODS: The Global CMR Registry (GCMR) was established in 2013 under the auspices of the Society for Cardiovascular Magnetic Resonance (SCMR). The GCMR team has developed a web-based data infrastructure, data use policy and participation agreement, data-harmonizing methods, and site-training tools based on results from an international survey of CMR programs. RESULTS: At present, 17 CMR programs have established a legal agreement to participate in GCMR, amongst them 10 have contributed CMR data, totaling 62,456 studies. There is currently a predominance of CMR centers with more than 10 years of experience (65%), and the majority are located in the United States (63%). The most common clinical indications for CMR have included assessment of cardiomyopathy (21%), myocardial viability (16%), stress CMR perfusion for chest pain syndromes (16%), and evaluation of etiology of arrhythmias or planning of electrophysiological studies (15%) with assessment of cardiomyopathy representing the most rapidly growing indication in the past decade. Most CMR studies involved the use of gadolinium-based contrast media (95%). CONCLUSIONS: We present the goals, mission and vision, infrastructure, preliminary results, and challenges of the GCMR. TRIAL REGISTRATION: Identification number on ClinicalTrials.gov: NCT02806193 . Registered 17 June 2016.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Sistema de Registros , Projetos de Pesquisa , Sociedades Científicas , Doenças Cardiovasculares/patologia , Doenças Cardiovasculares/fisiopatologia , Doenças Cardiovasculares/terapia , Meios de Contraste/administração & dosagem , Comportamento Cooperativo , Humanos , Cooperação Internacional , Internet/organização & administração , Objetivos Organizacionais , Valor Preditivo dos Testes , Prognóstico
19.
J Magn Reson Imaging ; 44(4): 983-92, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27042817

RESUMO

PURPOSE: To examine the feasibility of combining computational fluid dynamics (CFD) and dynamically scaled phantom phase-contrast magnetic resonance imaging (PC-MRI) for coronary flow assessment. MATERIALS AND METHODS: Left main coronary bifurcations segmented from computed tomography with bifurcation angles of 33°, 68°, and 117° were scaled-up ∼7× and 3D printed. Steady coronary flow was reproduced in these phantoms using the principle of dynamic similarity to preserve the true-scale Reynolds number, using blood analog fluid and a pump circuit in a 3T MRI scanner. After PC-MRI acquisition, the data were segmented and coregistered to CFD simulations of identical, but true-scale geometries. Velocities at the inlet region were extracted from the PC-MRI to define the CFD inlet boundary condition. RESULTS: The PC-MRI and CFD flow data agreed well, and comparison showed: 1) small velocity magnitude discrepancies (2-8%); 2) with a Spearman's rank correlation ≥0.72; and 3) a velocity vector correlation (including direction) of r(2) ≥ 0.82. The highest agreement was achieved for high velocity regions with discrepancies being located in slow or recirculating zones with low MRI signal-to-noise ratio (SNRv ) in tortuous segments and large bifurcating vessels. CONCLUSION: Characterization of coronary flow using a dynamically scaled PC-MRI phantom flow is feasible and provides higher resolution than current in vivo or true-scale in vitro methods, and may be used to provide boundary conditions for true-scale CFD simulations. J. MAGN. RESON. IMAGING 2016;44:983-992.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Coronária/fisiologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiologia , Angiografia por Ressonância Magnética/instrumentação , Modelos Cardiovasculares , Imagens de Fantasmas , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
J Cardiovasc Magn Reson ; 18: 8, 2016 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-26830817

RESUMO

BACKGROUND: UK Biobank's ambitious aim is to perform cardiovascular magnetic resonance (CMR) in 100,000 people previously recruited into this prospective cohort study of half a million 40-69 year-olds. METHODS/DESIGN: We describe the CMR protocol applied in UK Biobank's pilot phase, which will be extended into the main phase with three centres using the same equipment and protocols. The CMR protocol includes white blood CMR (sagittal anatomy, coronary and transverse anatomy), cine CMR (long axis cines, short axis cines of the ventricles, coronal LVOT cine), strain CMR (tagging), flow CMR (aortic valve flow) and parametric CMR (native T1 map). DISCUSSION: This report will serve as a reference to researchers intending to use the UK Biobank resource or to replicate the UK Biobank cardiovascular magnetic resonance protocol in different settings.


Assuntos
Bancos de Espécimes Biológicos , Protocolos Clínicos , Cardiopatias/diagnóstico , Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Feminino , Cardiopatias/patologia , Cardiopatias/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA