RESUMO
Rotor-stator axial clearance plays a pivotal role in ensuring the safety and efficiency of major rotating machinery. This paper introduces an innovative clearance measurement method based on wavelength division multiplexing (WDM) combined with all-fiber microwave photonic mixing. The method is distinguished by large measurement range, high accuracy and low drift. The WDM-based common optical path structure is established. A comprehensive theoretical model of axial clearance drift determined by wavelength and temperature is developed based on the thermo-optic effect of optical fiber material. To efficiently separate measurement and reference light at the probe, the optical design for a compact optical bandpass filter (OBPF) fiber sensor probe is proposed. The performance of the method is substantiated by simulations and experiments. The results demonstrate an accuracy of better than 2.8µm over a 23.5 mm range, surpassing existing methods. The method's capability to mitigate temperature-induced drift is further confirmed through high-temperature drift and comparative experiments.
RESUMO
A robust five-degree-of-freedom (5-DOF) measurement system is proposed in this paper. The compact optical configuration with high resolution is designed based on lens combination and multiple reflections. Beam drift and dual-beam parallelism are monitored and compensated by autocollimator units and a polarizer unit respectively. In addition, a protection method is proposed to reduce the intensity of air turbulence by reducing the Reynolds number of the beam path. The performance of the system is verified by experiments. The experimental results show that the self-compensation methods and air turbulence protection can effectively improve the accuracy and stability of the system under the long-term interference of external environments. The proposed system has high precision, desirable robustness, and convenient pre-calibration, which can be used for error measurement of precision machines.
RESUMO
In this paper, a high-accuracy measurement method for rotor-stator axial clearance in narrow spaces is proposed. The optical path structure based on all-fiber microwave photonic mixing is established. To improve the accuracy and expand the measurement range, the total coupling efficiency over the entire measurement range at different working distances of fiber probe was evaluated by Zemax analysis tool and theoretical model. The performance of the system was verified by experiments. The experimental results show that the measurement accuracy of axial clearance is better than 10.5 um within the range of 0.5-20.5 mm. The measurement accuracy has been effectively improved compared to previous methods. Additionally, the probe size is reduced to a mere diameter of 2.78 mm, which is more suitable for axial clearance measurement in narrow spaces inside rotating machines.
RESUMO
Rotor-stator axial clearance is a crucial design parameter affecting rotating machines' efficiency and safety. To accurately measure the dynamic axial clearance in high-speed machinery, a precise method based on time division multiplexing with frequency domain interferometry has been proposed. This method has proven robust and accurate through simulations and experiments. The inclusion of an optical switch enables the utilization of dispersive interferometry(DPI) and time division multiplexing for multiple channels of the light source. It achieves a static accuracy of 1.5â µm for a 15 mm range and a dynamic accuracy of 9â µm at 3000â rpm.
RESUMO
In the domain of frequency sweeping interferometry, the accurate extraction of distance information from nonlinear frequency scanning signals holds paramount significance in ensuring meticulous measurements of high precision. This paper presents a novel, to the best of our knowledge, high-speed distance extraction algorithm based on the table lookup method and validates its feasibility through theoretical models, simulations, and practical experiments. The proposed algorithm achieves comparable accuracy to traditional methods involving resampling and Hilbert transform. However, it outperforms them in robustness against noise and variations in sampling points. This method can accurately process signals sampled even below the Nyquist sampling rate. The simplicity and computational efficiency of the proposed approach make it suitable for various nonlinear sampling applications, promising broad applicability in scientific and engineering contexts.
RESUMO
The time-resolved polarized fluorescence of oriented R-phycoerythrin single crystal from red alga Porphyra yezoensis was studied in picosecond time scale. The fluorescence decay of the crystal exhibited two exponential processes, one of which was related to the energy transfer and excitation equilibrium between chromophores (tau(1)=60 ps), and the other to the fluorescent transition of chromophores (tau(2) approximate, equals 300 ps). The fluorescence of the crystal was highly depolarized due to excitation transfer between chromophores, and its anisotropic decay was distinctly dependent upon the crystal orientation because of the distribution of chromophore optical transition moments predominantly orienting around the principal axis of the crystal.