Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Microsc Microanal ; 25(1): 115-118, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30696493

RESUMO

It is shown that a xenon plasma focused ion beam (FIB) microscope is an excellent tool for high-quality preparation of functional oxide thin films for atomic resolution electron microscopy. Samples may be prepared rapidly, at least as fast as those prepared using conventional gallium FIB. Moreover, the surface quality after 2 kV final polishing with the Xe beam is exceptional with only about 3 nm of amorphized surface present. The sample quality was of a suitably high quality to allow atomic resolution high-angle annular dark field imaging and integrated differential phase contrast without any further preparation, and the resulting images were good enough for quantitative evaluation of atomic positions to reveal the oxygen octahedral tilt pattern. This suggests that such xenon plasma FIB instruments may find widespread application in transmission electron microscope and scanning transmission electron microscope specimen preparation.

2.
Opt Express ; 25(18): 21851-21860, 2017 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-29041477

RESUMO

Recent progress in phase modulation using nanofabricated electron holograms has demonstrated how the phase of an electron beam can be controlled. In this paper, we apply this concept to the correction of spherical aberration in a scanning transmission electron microscope and demonstrate an improvement in spatial resolution. Such a holographic approach to spherical aberration correction is advantageous for its simplicity and cost-effectiveness.

3.
J Am Chem Soc ; 137(10): 3474-7, 2015 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-25732196

RESUMO

Atomic resolution transmission electron microscopic observations at different electron acceleration voltages enabled us to observe visually the energy relaxation process of one conformer into another via rotation of various parts of the molecule. Cross-correlation analysis of sequential transmission electron microscopy (TEM) images or of the difference between experimental and simulated TEM images has been utilized for investigation of the conformational mobility and for structure identification of conformers.

4.
Nano Lett ; 14(1): 384-9, 2014 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-24329182

RESUMO

We present a new approach to study the three-dimensional compositional and structural evolution of metal alloys during heat treatments such as commonly used for improving overall material properties. It relies on in situ heating in a high-resolution scanning transmission electron microscope (STEM). The approach is demonstrated using a commercial Al alloy AA2024 at 100-240 °C, showing in unparalleled detail where and how precipitates nucleate, grow, or dissolve. The observed size evolution of individual precipitates enables a separation between nucleation and growth phenomena, necessary for the development of refined growth models. We conclude that the in situ heating STEM approach opens a route to a much faster determination of the interplay between local compositions, heat treatments, microstructure, and mechanical properties of new alloys.

5.
Phys Rev Lett ; 107(10): 107602, 2011 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-21981530

RESUMO

Using a combination of high-angle annular dark-field scanning transmission electron microscopy and atomically resolved electron energy-loss spectroscopy in an aberration-corrected transmission electron microscope we demonstrate the possibility of 2D atom by atom valence mapping in the mixed valence compound Mn3O4. The Mn L(2,3) energy-loss near-edge structures from Mn2+ and Mn3+ cation sites are similar to those of MnO and Mn2O3 references. Comparison with simulations shows that even though a local interpretation is valid here, intermixing of the inelastic signal plays a significant role. This type of experiment should be applicable to challenging topics in materials science, such as the investigation of charge ordering or single atom column oxidation states in, e.g., dislocations.

6.
Sci Rep ; 9(1): 10458, 2019 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-31320696

RESUMO

The key features of quantum mechanics are vividly illustrated by the Young-Feynman two-slit thought experiment, whose second part discusses the recording of an electron distribution with one of the two slits partially or totally closed by an aperture. Here, we realize the original Feynman proposal in a modern electron microscope equipped with a high brightness gun and two biprisms, with one of the biprisms used as a mask. By exciting the microscope lenses to conjugate the biprism plane with the slit plane, observations are carried out in the Fraunhofer plane with nearly ideal control of the covering of one of the slits. A second, new experiment is also presented, in which interference phenomena due to partial overlap of the slits are observed in the image plane. This condition is obtained by inserting the second biprism between the two slits and the first biprism and by biasing it in order to overlap their images.

7.
Sci Rep ; 8(1): 2676, 2018 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-29422551

RESUMO

Using state of the art scanning transmission electron microscopy (STEM) it is nowadays possible to directly image single atomic columns at sub-Å resolution. In standard (high angle) annular dark field STEM ((HA)ADF-STEM), however, light elements are usually invisible when imaged together with heavier elements in one image. Here we demonstrate the capability of the recently introduced Integrated Differential Phase Contrast STEM (iDPC-STEM) technique to image both light and heavy atoms in a thin sample at sub-Å resolution. We use the technique to resolve both the Gallium and Nitrogen dumbbells in a GaN crystal in [[Formula: see text]] orientation, which each have a separation of only 63 pm. Reaching this ultimate resolution even for light elements is possible due to the fact that iDPC-STEM is a direct phase imaging technique that allows fine-tuning the microscope while imaging. Apart from this qualitative imaging result, we also demonstrate a quantitative match of ratios of the measured intensities with theoretical predictions based on simulations.

8.
Ultramicroscopy ; 178: 38-47, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27554459

RESUMO

The phase and amplitude of the electron wavefunction that has passed through ultra-thin flakes of WSe2 is measured from high-resolution off-axis electron holograms. Both the experimental measurements and corresponding computer simulations are used to show that, as a result of dynamical diffraction, the spatially averaged phase does not increase linearly with specimen thickness close to an [001] zone axis orientation even when the specimen has a thickness of only a few layers. It is then not possible to infer the local specimen thickness of the WSe2 from either the phase or the amplitude alone. Instead, we show that the combined analysis of phase and amplitude from experimental measurements and simulations allows an accurate determination of the local specimen thickness. The relationship between phase and projected potential is shown to be approximately linear for extremely thin specimens that are tilted by several degrees in certain directions from the [001] zone axis. A knowledge of the specimen thickness then allows the electrostatic potential to be determined from the measured phase. By using this combined approach, we determine a value for the mean inner potential of WSe2 of 18.9±0.8V, which is 12% lower than the value calculated from neutral atom scattering factors.

9.
Chem Commun (Camb) ; 49(92): 10859-61, 2013 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-24127075

RESUMO

An approach to carry out chemical reactions using aggressive gases in situ in a transmission electron microscope (TEM), at ambient pressures of 1.5 bar using a windowed environmental cell, called a nanoreactor, is presented here. The nanoreactor coupled with a specially developed holder with platinum tubing permits the usage of aggressive chemicals like hydrochloric acid (HCl).

10.
ACS Nano ; 7(2): 1566-72, 2013 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-23343745

RESUMO

We show that by operating a scanning transmission electron microscope (STEM) with a 0.1 nm 300 kV electron beam, one can sculpt free-standing monolayer graphene with close-to-atomic precision at 600 °C. The same electron beam that is used for destructive sculpting can be used to image the sculpted monolayer graphene nondestructively. For imaging, a scanning dwell time is used that is about 1000 times shorter than for the sculpting. This approach allows for instantaneous switching between sculpting and imaging and thus fine-tuning the shape of the sculpted lattice. Furthermore, the sculpting process can be automated using a script. In this way, free-standing monolayer graphene can be controllably sculpted into patterns that are predefined in position, size, and orientation while maintaining defect-free crystallinity of the adjacent lattice. The sculpting and imaging processes can be fully computer-controlled to fabricate complex assemblies of ribbons or other shapes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA