Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Infect Dis ; 229(5): 1317-1327, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38390982

RESUMO

BACKGROUND: Chronic inflammation is prevalent with antiretroviral therapy (ART)-suppressed human immunodeficiency virus (HIV) infection and one immune cell subset putatively driving this phenomenon is TIGIT+ γδ T cells. METHODS: To elucidate γδ T-cell phenotypic diversity, spectral flow cytometry was performed on blood lymphocytes from individuals of a HIV and aging cohort and data were analyzed using bioinformatic platforms. Plasma inflammatory markers were measured and correlated with γδ T-cell subset frequencies. RESULTS: Thirty-nine distinct γδ T-cell subsets were identified (22 Vδ1+, 14 Vδ2+, and 3 Vδ1-Vδ2-Vγ9+) and TIGIT was nearly exclusively found on the Vδ1+CD45RA+CD27- effector populations. People with ART-suppressed HIV infection (PWH) exhibited high frequencies of distinct clusters of Vδ1+ effectors distinguished via CD8, CD16, and CD38 expression. Among Vδ2+ cells, most Vγ9+ (innate-like) clusters were lower in PWH; however, CD27+ subsets were similar in frequency between participants with and without HIV. Comparisons by age revealed lower 'naive' Vδ1+CD45RA+CD27+ cells in older individuals, regardless of HIV status. Plasma inflammatory markers were selectively linked to subsets of Vδ1+ and Vδ2+ cells. CONCLUSIONS: These results further elucidate γδ T-cell subset complexity and reveal distinct alterations and connections with inflammatory pathways of Vδ1+ effector and Vδ2+ innate-like subsets during ART-suppressed HIV infection.


Assuntos
Infecções por HIV , Receptores de Antígenos de Linfócitos T gama-delta , Subpopulações de Linfócitos T , Humanos , Infecções por HIV/tratamento farmacológico , Infecções por HIV/imunologia , Infecções por HIV/sangue , Masculino , Pessoa de Meia-Idade , Subpopulações de Linfócitos T/imunologia , Feminino , Adulto , Biomarcadores/sangue , Idoso , Inflamação/sangue , Antirretrovirais/uso terapêutico , Citometria de Fluxo , Receptores Imunológicos/sangue , Estudos de Coortes , Linfócitos Intraepiteliais/imunologia
2.
Cancer Discov ; 14(7): 1176-1189, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38583184

RESUMO

Therapeutic approaches for clear cell renal cell carcinoma (ccRCC) remain limited; however, chimeric antigen receptor (CAR) T-cell therapies may offer novel treatment options. CTX130, an allogeneic CD70-targeting CAR T-cell product, was developed for the treatment of advanced or refractory ccRCC. We report that CTX130 showed favorable preclinical proliferation and cytotoxicity profiles and completely regressed RCC xenograft tumors. We also report results from 16 patients with relapsed/refractory ccRCC who received CTX130 in a phase I, multicenter, first-in-human clinical trial. No patients encountered dose-limiting toxicity, and disease control was achieved in 81.3% of patients. One patient remains in a durable complete response at 3 years. Finally, we report on a next-generation CAR T construct, CTX131, in which synergistic potency edits to CTX130 confer improved expansion and efficacy in preclinical studies. These data represent a proof of concept for the treatment of ccRCC and other CD70+ malignancies with CD70- targeted allogeneic CAR T cells. Significance: Although the role of CAR T cells is well established in hematologic malignancies, the clinical experience in solid tumors has been disappointing. This clinical trial demonstrates the first complete response in a patient with RCC, reinforcing the potential benefit of CAR T cells in the treatment of solid tumors.


Assuntos
Ligante CD27 , Carcinoma de Células Renais , Imunoterapia Adotiva , Neoplasias Renais , Humanos , Carcinoma de Células Renais/terapia , Carcinoma de Células Renais/imunologia , Animais , Neoplasias Renais/terapia , Neoplasias Renais/imunologia , Imunoterapia Adotiva/métodos , Camundongos , Feminino , Masculino , Pessoa de Meia-Idade , Receptores de Antígenos Quiméricos/imunologia , Idoso , Ensaios Antitumorais Modelo de Xenoenxerto , Linhagem Celular Tumoral , Adulto
3.
Pediatr Infect Dis J ; 42(3): e70-e76, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36729773

RESUMO

BACKGROUND: Coronavirus disease 2019 [severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)] infection at varying time points during the pregnancy can influence antibody levels after delivery. We aimed to examine SARS-CoV-2 IgG, IgM and IgA receptor binding domain of the spike protein and nucleocapsid protein (N-protein) reactive antibody concentrations in maternal blood, infant blood and breastmilk at birth and 6 weeks after SARS-CoV-2 infection in early versus late gestation. METHODS: Mothers with SARS-CoV-2 infection during pregnancy were enrolled between July 2020 and May 2021. Maternal blood, infant blood and breast milk samples were collected at delivery and 6 weeks postpartum. Samples were analyzed for SARS-CoV-2 spike and N-protein reactive IgG, IgM and IgA antibodies. Antibody concentrations were compared at the 2 time points and based on trimester of infection ("early" 1st/2nd vs. "late" 3rd). RESULTS: Dyads from 20 early and 11 late trimester infections were analyzed. For the entire cohort, there were no significant differences in antibody levels at delivery versus 6 weeks with the exception of breast milk levels which declined over time. Early gestation infections were associated with higher levels of breastmilk IgA to spike protein ( P = 0.04). Infant IgG levels to spike protein were higher at 6 weeks after late infections ( P = 0.04). There were strong correlations between maternal and infant IgG levels at delivery ( P < 0.01), and between breastmilk and infant IgG levels. CONCLUSIONS: SARS-CoV-2 infection in early versus late gestation leads to a persistent antibody response in maternal blood, infant blood and breast milk over the first 6 weeks after delivery.


Assuntos
COVID-19 , Leite Humano , Recém-Nascido , Feminino , Gravidez , Lactente , Humanos , Formação de Anticorpos , Glicoproteína da Espícula de Coronavírus , SARS-CoV-2 , Parto , Anticorpos Antivirais , Imunoglobulina A , Imunoglobulina G , Mães , Imunoglobulina M
4.
Front Immunol ; 12: 614676, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33897682

RESUMO

The COVID-19 pandemic has drastically impacted work, economy, and way of life. Sensitive measurement of SARS-CoV-2 specific antibodies would provide new insight into pre-existing immunity, virus transmission dynamics, and the nuances of SARS-CoV-2 pathogenesis. To date, existing SARS-CoV-2 serology tests have limited utility due to insufficient reliable detection of antibody levels lower than what is typically present after several days of symptoms. To measure lower quantities of SARS-CoV-2 IgM, IgG, and IgA with higher resolution than existing assays, we developed a new ELISA protocol with a distinct plate washing procedure and timed plate development via use of a standard curve. Very low optical densities from samples added to buffer coated wells at as low as a 1:5 dilution are reported using this 'BU ELISA' method. Use of this method revealed circulating SARS-CoV-2 receptor binding domain (RBD) and nucleocapsid protein (N) reactive antibodies (IgG, IgM, and/or IgA) in 44 and 100 percent of pre-pandemic subjects, respectively, and the magnitude of these antibodies tracked with antibody levels of analogous viral proteins from endemic coronavirus (eCoV) strains. The disease status (HIV, SLE) of unexposed subjects was not linked with SARS-CoV-2 reactive antibody levels; however, quantities were significantly lower in subjects over 70 years of age compared with younger counterparts. Also, we measured SARS-CoV-2 RBD- and N- specific IgM, IgG, and IgA antibodies from 29 SARS-CoV-2 infected individuals at varying disease states, including 10 acute COVID-19 hospitalized subjects with negative serology results by the EUA approved Abbott IgG chemiluminescent microparticle immunoassay. Measurements of SARS-CoV-2 RBD- and N- specific IgM, IgG, IgA levels measured by the BU ELISA revealed higher signal from 9 of the 10 Abbott test negative COVID-19 subjects than all pre-pandemic samples for at least one antibody specificity/isotype, implicating improved serologic identification of SARS-CoV-2 infection via multi-parameter, high sensitive antibody detection. We propose that this improved ELISA protocol, which is straightforward to perform, low cost, and uses readily available commercial reagents, is a useful tool to elucidate new information about SARS-CoV-2 infection and immunity and has promising implications for improved detection of all analytes measurable by this platform.


Assuntos
Envelhecimento/imunologia , Anticorpos Antivirais/imunologia , Teste Sorológico para COVID-19 , COVID-19/imunologia , SARS-CoV-2/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Envelhecimento/sangue , Anticorpos Antivirais/sangue , COVID-19/sangue , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , SARS-CoV-2/metabolismo , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA