Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 104(1): 61-70, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38736246

RESUMO

BACKGROUND: Stent implantation has become standard of care in older children and adults for treatment of branch pulmonary artery stenosis (BPAS) and coarctation aorta (CoAo). There are no stents approved or available for infants that have the potential to be dilated to adult diameters. The Minima stent was designed to fulfill this unmet need. METHODS: Multicenter, prospective, nonrandomized early feasibility study evaluating safety and effectiveness of the Minima stent for treatment of BPAS and CoAo. Primary endpoints included: (1) successful deployment across lesion, (2) stenosis relief defined by an increase in angiographic diameter of >50% and (3) freedom from stent explant, embolization or migration at 30 days and 6 months. RESULTS: Between 2/2022 and 5/2022, 10 pts underwent Minima stent implantation with a median age and weight of 9 months (4-43 months) and 7.6 kg (5.1-16.9 kg). Procedural success and predefined stenosis relief was achieved in all cases (CoAo [n = 4], BPAS [n = 6]). Adverse events occurred in 3 pts: transient diminished lower extremity pulse (n = 2), distal stent on-balloon displacement successfully managed in the catheterization suite (n = 1). There were no deaths or major adverse events. All patients were free from stent explant and migration at 30 days and 6 months with no evidence for significant restenosis at latest follow-up. CONCLUSIONS: Implantation of the Renata Minima stent was safe and effective for the treatment of BPAS and CoAo in this small cohort of infants and young children during early follow-up. Based on these early results, an expanded study with longer follow-up is warranted.


Assuntos
Coartação Aórtica , Estudos de Viabilidade , Desenho de Prótese , Estenose de Artéria Pulmonar , Stents , Humanos , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/terapia , Coartação Aórtica/fisiopatologia , Lactente , Estudos Prospectivos , Masculino , Feminino , Resultado do Tratamento , Estenose de Artéria Pulmonar/diagnóstico por imagem , Estenose de Artéria Pulmonar/fisiopatologia , Estenose de Artéria Pulmonar/terapia , Estenose de Artéria Pulmonar/etiologia , Fatores de Tempo , Pré-Escolar , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Fatores Etários , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos
2.
Catheter Cardiovasc Interv ; 103(6): 934-942, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38584522

RESUMO

BACKGROUND: Transcatheter closure of the patent ductus arteriosus (PDA) in premature infants is currently dependent on fluoroscopic guidance and transportation to the catheterization laboratory. AIM: We describe a new echocardiographically guided technique to allow our team to move to the bedside at the neonatal intensive care unit (NICU) of the referring center for percutaneous treatment of PDA in premature infants. METHODS: This is a single-center, retrospective, primarily descriptive analysis. Clinical details about the procedure, its outcomes, and complications were collected. RESULTS: Fifty-eight neonates with a median weight of 1110 g (range 730-2800) and postnatal age of 28 days (range 9-95) underwent percutaneous PDA closure. Five of them were treated in our center with ultrasound guidance only and the other 53 in 18 different neonatology units in 12 towns. The median duration of the procedure was 40 min (range 20-195 min). There were no procedural deaths. There was one residual shunt for 3 weeks, in all other patients the duct closed completely in the first few hours after the intervention. In one patient the procedure had to be interrupted because of a pericardial effusion which had to be drained, the PDA was closed successfully interventionally 5 days later. One device-related aortic coarctation had to be stented. One embolization and one late migration occurred and required treatment. CONCLUSIONS: Echocardiographically guided transcatheter closure of the PDA in prematures was repeatedly possible and allowed that the procedure is performed at the bedside at the NICU with an acceptable rate of complications.


Assuntos
Cateterismo Cardíaco , Permeabilidade do Canal Arterial , Ultrassonografia de Intervenção , Humanos , Permeabilidade do Canal Arterial/terapia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Recém-Nascido , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Resultado do Tratamento , Idade Gestacional , Valor Preditivo dos Testes , Masculino , Feminino , Fatores de Tempo , Índice de Gravidade de Doença , Recém-Nascido Prematuro , Lactente Extremamente Prematuro , Unidades de Terapia Intensiva Neonatal , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Dispositivo para Oclusão Septal , Lactente
3.
Eur J Orthop Surg Traumatol ; 33(4): 955-960, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35230543

RESUMO

PURPOSE: The objectives of this study were to assess the incidence of vitamin D deficiency in orthopaedic trauma patients, evaluate the safety and efficacy of a vitamin D supplementation protocol, and investigate the utility of vitamin D supplementation in reducing nonunions. METHODS: Three hundred seventy patients with operative tibia and/or fibula fractures were retrospectively reviewed. Both overall and matched cohorts were analysed. RESULTS: Ninety-eight per cent (n = 210) were found to have vitamin D insufficiency (serum 25(OH)D level < 30 ng/ml). There were no cases of vitamin D toxicity following vitamin D replacement. Median follow-up vitamin D level was 22.7 ng/mL. No statistical difference between union rates was found between either the two consecutive cohorts or matched cohorts. CONCLUSION: This vitamin D replacement protocol was a safe treatment for hypovitaminosis D, but post hoc analysis shows there would need to be over 1200 matched patients to achieve adequate power.


Assuntos
Fraturas Ósseas , Ortopedia , Deficiência de Vitamina D , Humanos , Fraturas Ósseas/epidemiologia , Estudos Retrospectivos , Deficiência de Vitamina D/epidemiologia , Deficiência de Vitamina D/terapia , Vitamina D , Vitaminas , Suplementos Nutricionais
4.
Catheter Cardiovasc Interv ; 98(1): 117-127, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33942962

RESUMO

OBJECTIVES: This study sought to obtain in vivo data on a new stent and delivery system specifically designed for implantation in infants with the ability to be enlarged to adult dimensions. BACKGROUND: There are no endovascular stents designed for or approved for use in infants, nor is there a stent capable of being implanted at infant vessel diameters and achieving adult size while maintaining structural integrity. The Minima stent was designed to address these needs. METHODS: This study was performed in 6 piglets who underwent implantation of 22 Minima stents into the following locations: aorta (n = 11), branch pulmonary arteries (n = 6), and central veins (n = 5). RESULTS: Successful deployment occurred in 21/22 attempts. Two instances of post-deployment migration occurred. Stents were re-expanded at 1, 2, 3 and 5 months after implant. All stents regardless of location could be re-dilated to the intended diameter to keep pace with somatic growth (implant diameter 6.9 +/- 1.2 mm; final diameter 16.1 mm +/- 1.4 mm). Histopathology at 1 and 5 months demonstrated widely patent vessel lumens with stent apposition to vessel wall, early mild inflammatory response surrounding stent struts, typical vascular damage and healing response to acute dilation and a progressive smooth neointimal growth covering stent struts over time. CONCLUSIONS: In this in vivo study of the Minima stent, there was high implant success, predictable re-dilatability to adult diameters and favorable histopathology. Further study is warranted.


Assuntos
Artéria Pulmonar , Stents , Adulto , Animais , Aorta , Humanos , Lactente , Neointima , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Suínos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 98(1): 128-136, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33909945

RESUMO

BACKGROUND: Covered stent correction of sinus venosus ASDs (SVASD) is a relatively new technique. Challenges include anchoring a sufficiently long stent in a nonstenotic superior vena cava (SVC) and expanding the stent at the wider SVC-RA junction without obstructing the anomalous right upper pulmonary vein (RUPV). The 10-zig covered Cheatham-platinum (CCP) stent has the advantage of being available in lengths of 5-11 cm and dilatable to 34 mm in diameter. METHODS: An international registry reviewed the outcomes of 10-zig CCP stents in 75 patients aged 11.4-75.9 years (median 45.4) from March 2016. Additional stents were used to anchor the stent in the SVC or close residual shunts in 33/75. An additional stent was placed in 4/5 (80%) with 5/5.5 cm CCPs, 18/29 (62%) with 6 cm CCPs, 5/18 (28%) with 7 cm CCPs, 5/22 (23%) with 7.5/8 cm CCPs and 0/1 with an 11 cm CCP. A "protective" balloon catheter was inflated in the RUPV in 17. RESULTS: Early stent embolization in two patients required surgical removal and defect repair and tamponade was drained in one patient. The CT at 3 months showed occlusion of the RUPV in one patient. Follow up is from 2 months to 5.1 years (median 1.8 years). QP:QS has reduced from 2.5 ± 0.5 to 1.2 ± 0.36 (p < .001) and RVEDVi from 149.1 ± 35.4 to 95.6 ± 21.43 ml/m2 (p < .001). CONCLUSIONS: Ten-zig CCPs of 7-8 cm appear to provide reliable SVASD closure with a low requirement for additional stents. Careful selection of patients and meticulous attention to detail is required to avoid complications.


Assuntos
Comunicação Interatrial , Platina , Humanos , Sistema de Registros , Stents , Resultado do Tratamento , Veia Cava Superior
6.
Pediatr Cardiol ; 42(7): 1640-1646, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34050375

RESUMO

Transcatheter pulmonary valve replacement (TPVR) is a staple in the pediatric cardiac catheterization lab. Despite the ubiquitous use of this procedure, guidelines for antithrombosis post pulmonary valve replacement are non-existent. A survey was sent out via email to the members of the Congenital Cardiovascular Interventional Study Consortium (CCISC) and the Pediatric and Adult Interventional Cardiac Symposium (PICS-AICS). Responses were received from 109 cardiologists who perform this procedure. Following TPVR 76.5% of respondents use only Aspirin, while the remainder prescribe a second antithrombotic agent at discharge. The majority (78%) of respondents do not educate patients about avoiding enteric formulations of aspirin, and another 86% do not educate patients about the need to avoid proton pump inhibitors (PPI). In addition, 67% do not advise against concomitant use of Non-Steroidal Anti-Inflammatory Drugs (NSAIDs). Lastly, the survey showed a wide discrepancy in prescribed dose with 56% choosing to always prescribe 70-100 mg regardless of weight, 28% choosing to do weight-based dosing, and 7.5% choosing 325 mg regardless of weight. In a survey sent out to pediatric cardiac interventionalists worldwide, a significant discrepancy was noted in antithrombotic regimens used following TPVR. We hypothesize that these discrepancies may contribute to early valve failure and suggest the need for further study and the development of unified antithrombosis guidelines following TPVR.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Adulto , Aspirina , Cateterismo Cardíaco , Criança , Humanos , Valva Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
7.
Pediatr Cardiol ; 42(3): 628-636, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33394112

RESUMO

Transcatheter patent ductus arteriosus closure (TCPC) is an emerging treatment for low birth weight extremely premature neonates (EPNs). Left pulmonary artery (LPA) and descending aorta (DAO) obstruction are described device-related complications, however, data on mid- and long-term vascular outcomes are lacking. A retrospective analysis of EPNs who underwent successful TCPC at our institution from 03/2013 to 12/2018 was performed. Two-dimensional echocardiography and spectral Doppler velocities from various time points before and after TCPC were used to identify LPA and DAO flow disturbances. A total of 44 EPNs underwent successful TCPC at a median (range) procedural weight of 1150 g (755-2500 g). Thirty-two (73%) patients were closed with the AVP II and 12 (27%) with the Amplatzer Piccolo device. LPA and DAO velocities on average remained within normal limits and improved spontaneously in long-term follow up (26.1 months, range 1-75 months). One patient, who had concerning LPA flow characteristics immediately after device implant (peak velocity 2.6 m/s) developed progressive LPA stenosis requiring stent placement 3 months post-procedure. In the remaining infants, including 7 (16%) who developed LPA and 3 (7%) who developed DAO flow disturbances (range 2-2.4 m/s), all had progressive normalization of flow velocities over time. TCPC can be performed safely in EPNs with a low incidence of LPA and DAO obstruction. In the absence of significant progressive vascular obstruction in the early post-procedure period, mild increases in LPA and DAO flow velocities tend to improve spontaneously and normalize in long-term follow-up.


Assuntos
Cateterismo Cardíaco/métodos , Permeabilidade do Canal Arterial/cirurgia , Aorta Torácica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Feminino , Humanos , Lactente , Recém-Nascido de Baixo Peso , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Artéria Pulmonar/fisiopatologia , Estudos Retrospectivos , Fatores de Risco , Estenose de Artéria Pulmonar/etiologia , Resultado do Tratamento
8.
Pediatr Cardiol ; 42(6): 1258-1274, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34195869

RESUMO

Transcatheter closure of patent ductus arteriosus (PDA) in premature infants is a feasible, safe, and an effective alternative to surgical ligation and may be performed with an implant success rate of 97%. Major procedural complications related to transcatheter PDA closure in extremely low birth weight (ELBW) infants are relatively infrequent (< 3%) ,but may be associated with a fatality if not optimally managed. Operators performing transcatheter PDA closures should be knowledgeable about these potential complications and management options. Prompt recognition and treatment are often necessary to avoid serious consequences. With strict guidelines on operator training, proctoring requirements, and technical refinements, transcatheter PDA closure in ELBW infants can be performed safely with low complication rates. This article summarizes the consensus guidelines put forward by a panel of physicians for the prevention and management of periprocedural complications of transcatheter PDA closure with the Amplatzer Piccolo Occluder in ELBW infants.


Assuntos
Consenso , Permeabilidade do Canal Arterial/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Guias de Prática Clínica como Assunto , Dispositivo para Oclusão Septal/efeitos adversos , Humanos , Lactente , Recém-Nascido de Peso Extremamente Baixo ao Nascer
9.
Catheter Cardiovasc Interv ; 96(6): 1266-1276, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32433821

RESUMO

OBJECTIVES: Characterize the safety and effectiveness of the Amplatzer Piccolo Occluder for patent ductus arteriosus (PDA) closure. BACKGROUND: The presence of a hemodynamically significant PDA has been associated with an increased risk of morbidity and mortality in children born premature. METHODS: This was a single arm, prospective, multicenter, non-randomized study to evaluate the Amplatzer Piccolo Occluder to treat PDA in patients ≥700 g. From June 2017 to February 2019, 200 patients were enrolled at nine centers, with 100 patients weighing ≤2 kg. Primary effectiveness endpoint was the rate of PDA closure at 6-month follow-up. Primary safety endpoint was the rate of major complications through 6 months. Secondary endpoint was rate of significant pulmonary or aortic obstruction through 6 months' follow-up. RESULTS: The implant success rate was 95.5% (191/200) overall and 99% in patients ≤2 kg (99/100). The primary effectiveness endpoint was achieved in 99.4% of implanted patients. Four patients experienced a primary safety endpoint event (2 transfusions, 1 hemolysis, and 1 aortic obstruction). There were no branch pulmonary artery obstructions. Five patients, all ≤2 kg, were noted to have worsening of tricuspid regurgitation (TR) after the procedure. None of the TR incidences manifested clinically. The Amplatzer Piccolo Occluder received FDA approval in January 2019 and became the first device approved for PDA closure in patients ≥700 g. CONCLUSIONS: This study supports the safety and effectiveness of the Amplatzer Piccolo Occluder, particularly in patients between 700 g and 2 kg where there is currently a significant unmet need in the United States. ClinicalTrials.gov identifier: NCT03055858.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Lactente Extremamente Prematuro , Recém-Nascido de muito Baixo Peso , Dispositivo para Oclusão Septal , Peso ao Nascer , Cateterismo Cardíaco/efeitos adversos , Circulação Coronária , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Idade Gestacional , Hemodinâmica , Humanos , Recém-Nascido , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
10.
Catheter Cardiovasc Interv ; 96(6): 1258-1265, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32840956

RESUMO

The society for cardiovascular angiography and interventions (SCAI) think tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community for high-level field-wide discussions. The 2020 think tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease (CHD). Each session was moderated by a senior content expert and co-moderated by a member of SCAI's emerging leader mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialogue from a broader base, and thereby aid SCAI and the industry community in developing specific action items to move these areas forward.


Assuntos
Cateterismo Cardíaco/tendências , Cardiologia/tendências , Angiografia Coronária/tendências , Cardiopatias/diagnóstico por imagem , Cardiopatias/terapia , Intervenção Coronária Percutânea/tendências , Difusão de Inovações , Cardiopatias/fisiopatologia , Humanos
11.
Curr Cardiol Rep ; 22(10): 125, 2020 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-32789652

RESUMO

PURPOSE OF REVIEW: Advanced imaging has played a vital role in the contemporary, rapid rise of structural heart interventions. 3D modeling and printing has emerged as one of the most recent imaging tools and the implementation of 3D modeling is expected to increase with further advances in imaging, print hardware, and materials. RECENT FINDINGS: 3D modeling can be used to educate patients and clinical teams, provide ex vivo procedural simulation, and improve outcomes. Intra-procedural success rates may be improved, and post-procedural complications can be predicted more robustly with appropriate application of 3D modeling. Recent advances in technology have increased the availability of this tool, such that there can be more ready adoption into a routine clinical workflow. Familiarity with 3D modeling and its current utilization and role in structural interventions will help inform how to approach and adapt this exciting new technology.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Doenças das Valvas Cardíacas , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Humanos
12.
Catheter Cardiovasc Interv ; 93(3): 455-463, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30537348

RESUMO

OBJECTIVES: To describe a multi-center experience of percutaneous transcatheter pulmonary valve replacement (TPVR) using the Edwards Sapien S3 Valve. BACKGROUND: Off-label use of the Sapien S3 valve can allow for TPVR in patients with congenital heart disease (CHD) and large diameter dysfunctional right ventricular outflow tract (RVOT). The initial experience at five centers with the SAPIEN S3 valve for TPVR is presented with a focus on procedural techniques, success, complications, and efficacy. METHODS: A retrospective review was performed of all patients with CHD and dysfunctional RVOT who underwent TPVR using Sapien S3 valve. Imaging data, procedural elements, and clinical follow-up data were collected to evaluate acute and short-term results. RESULTS: A total of 50 patients underwent percutaneous placement of the Sapien S3 in the pulmonary position. Of these, 38 were placed into "native RVOTs", measuring 24-32 mm in diameter, as assessed by compliant balloon sizing. In all cases, the valve was implanted after introduction and there were no cases of valve embolization. On follow up (range 1-9 months, median 3 months), no patients had significant obstruction or regurgitation through or around the valve requiring intervention. There were no procedural deaths. Major complications included severe aortic compression (n = 1) and tricuspid valve (TV) injury related to valve placement (n = 2) and prestenting (n = 1). CONCLUSIONS: TPVR in patients with large diameter dysfunctional RVOTs can be effectively performed with the Sapien S3. All procedures were technically successful with no embolizations, no perivalvular leaks, and excellent short-term valve function. Tricuspid valve injury from implantation of an uncovered valve was a serious procedural complication.


Assuntos
Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Adolescente , Adulto , Valvuloplastia com Balão , Cateterismo Cardíaco/efeitos adversos , Criança , Feminino , Cardiopatias Congênitas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
13.
Cardiol Young ; 29(12): 1419-1425, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31662138

RESUMO

The history of congenital interventional cardiology has seen numerous groundbreaking innovations typically related to the introduction of a new device or a novel treatment technique. Similarly, imaging of cardiac defects has changed dramatically over the past decades, although some of the advancements have seemed to omit the catheterisation laboratories. Rotational angiography, one of the imaging techniques for guidance of cardiac catheterisation currently referred to as "advanced", in fact was described already in 1960s.1 More recently its improved version, including three-dimensional reconstruction (3DRA), became a valuable intra-procedural imaging tool in interventional cardiology and neuroradiology.2 Dr Evan Zahn was one of the pioneers of 3DRA in the field of congenital cardiology, setting an example for many to follow. With his innovative publication and subsequent lecture at 2011 Pediatric and Adult Interventional Cardiac Symposium (PICS-AICS) on "The Emerging Use of 3-Dimensional Rotational Angiography in Congenital Heart Disease" he motivated many to explore benefits of this modality to strive for improved procedural outcomes and reduced patients' burden of cardiac catheterisation3. I was one of those to take Dr Zahn's thoughts and implement them into routine workflow.4-6 However, almost a decade after Dr Zahn shared his important work, despite tremendous efforts by teams from Utrecht, (Netherlands) and Columbus (Ohio, United States of America) to popularise 3D imaging in catheterisation laboratory during dedicated meetings, two-dimensional (2D) angiography does not seem to be threatened in many, otherwise-progressive, laboratories. During the recent 30th Japanese Pediatric Interventional Cardiology (JPIC) meeting I had the opportunity to ask Dr Zahn why giving up knowledge is almost never a good idea, what is technology's natural order of things, and why the technology has to be more than just exciting, pretty, and new.


Assuntos
Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Imageamento Tridimensional/métodos , Angiografia Coronária/métodos , Humanos , Realidade Virtual
14.
Catheter Cardiovasc Interv ; 91(6): 1125-1129, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29521437

RESUMO

Current balloon expandable transcatheter valves have limited applicability to patients with "native" right ventricular outflow tracts (RVOT), meaning those who have had previous surgery and are left with large, compliant, irregular RVOT. The Alterra Adaptive PrestentTM is a self-expanding, partially covered stent that was designed to internally reconfigure these types of RVOT, making them suitable for implantation of a commercially available balloon expandable heart valve, the SAPIEN 3. Herein, we describe the first human implant of this device.


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hipertrofia Ventricular Direita/cirurgia , Insuficiência da Valva Pulmonar/cirurgia , Stents , Função Ventricular Direita , Remodelação Ventricular , Cateterismo Cardíaco/métodos , Angiografia por Tomografia Computadorizada , Ecocardiografia Doppler em Cores , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Hipertrofia Ventricular Direita/diagnóstico por imagem , Hipertrofia Ventricular Direita/fisiopatologia , Pessoa de Meia-Idade , Modelos Cardiovasculares , Desenho de Prótese , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Resultado do Tratamento
15.
Circulation ; 131(22): 1960-70, 2015 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-25944758

RESUMO

BACKGROUND: Studies of transcatheter pulmonary valve (TPV) replacement with the Melody valve have demonstrated good short-term outcomes, but there are no published long-term follow-up data. METHODS AND RESULTS: The US Investigational Device Exemption trial prospectively enrolled 171 pediatric and adult patients (median age, 19 years) with right ventricular outflow tract conduit obstruction or regurgitation. The 148 patients who received and were discharged with a TPV were followed up annually according to a standardized protocol. During a median follow-up of 4.5 years (range, 0.4-7 years), 32 patients underwent right ventricular outflow tract reintervention for obstruction (n=27, with stent fracture in 22), endocarditis (n=3, 2 with stenosis and 1 with pulmonary regurgitation), or right ventricular dysfunction (n=2). Eleven patients had the TPV explanted as an initial or second reintervention. Five-year freedom from reintervention and explantation was 76±4% and 92±3%, respectively. A conduit prestent and lower discharge right ventricular outflow tract gradient were associated with longer freedom from reintervention. In the 113 patients who were alive and reintervention free, the follow-up gradient (median, 4.5 years after implantation) was unchanged from early post-TPV replacement, and all but 1 patient had mild or less pulmonary regurgitation. Almost all patients were in New York Heart Association class I or II. More severely impaired baseline spirometry was associated with a lower likelihood of improvement in exercise function after TPV replacement. CONCLUSIONS: TPV replacement with the Melody valve provided good hemodynamic and clinical outcomes up to 7 years after implantation. Primary valve failure was rare. The main cause of TPV dysfunction was stenosis related to stent fracture, which was uncommon once prestenting became more widely adopted. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00740870.


Assuntos
Cateterismo Cardíaco/tendências , Implante de Prótese de Valva Cardíaca/tendências , Hemodinâmica , Insuficiência da Valva Pulmonar/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Adolescente , Adulto , Criança , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Insuficiência da Valva Pulmonar/diagnóstico , Insuficiência da Valva Pulmonar/epidemiologia , Resultado do Tratamento , Estados Unidos/epidemiologia , Obstrução do Fluxo Ventricular Externo/diagnóstico , Obstrução do Fluxo Ventricular Externo/epidemiologia , Adulto Jovem
16.
Catheter Cardiovasc Interv ; 87(3): 403-10, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26527499

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (tPVR) is an accepted therapy for treatment of dysfunctional right ventricular outflow tract (RVOT) conduits. At present, the majority of Fallot patients who undergo transannular patch (TAP) repair are not candidates for tPVR due to the large irregular nature of their RVOT. Herein, we describe a novel approach to assessing the RVOT in this group, which may then be used to design, test, and carry out hybrid RVOT modification and transcatheter valve implantation in this population. METHODS: A retrospective analysis of TAP patients who underwent 3D modeling of the RVOT which was then used to develop individualized hybrid procedures designed to modify the RVOT, thereby rendering patients suitable for transcatheter valve implantation. RESULTS: Eight consecutive patients underwent 3D RVOT modeling followed by hybrid implantation of a transcatheter valve via a perventricular approach. A landing zone stent was placed in all and four required additional intravascular geometric remodeling of the RVOT prior to valve implant. Transcatheter valves were successfully implanted in all. There were no instances of valve malposition, embolization, or death. There was one minor procedural complication. No patient had more than trivial pulmonary regurgitation at follow-up. CONCLUSIONS: Using a hybrid approach to remodel the RVOT in TAP patients supported by preprocedural 3D-model planning allows for successful tPVR implantation in this population. A larger cohort and longer follow-up will be needed to determine the ultimate utility of this approach.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Pulmonar/terapia , Valva Pulmonar , Tetralogia de Fallot/cirurgia , Adolescente , Adulto , Cateterismo Cardíaco/instrumentação , Criança , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Modelos Anatômicos , Modelos Cardiovasculares , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Radiografia Intervencionista , Estudos Retrospectivos , Stents , Tetralogia de Fallot/diagnóstico , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
17.
Cardiol Young ; 26(5): 948-56, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26521753

RESUMO

BACKGROUND: Transcatheter pulmonary valve implantation is usually performed from a femoral venous - transfemoral - approach, but this may not be the optimal vascular access option in some patients. This study aimed to determine which group of patients might benefit from an internal jugular - transjugular - approach for transcatheter pulmonary valve implantation. METHODS: This multicentre retrospective study included all patients who underwent attempted transcatheter pulmonary valve placement in the right ventricular outflow tract between April 2010 and June 2012 at two large congenital heart centres. Patients were divided into two groups based on venous access site - transfemoral or transjugular. Patient characteristics, procedural outcomes, and complications were compared between groups. RESULTS: Of 81 patients meeting the inclusion criteria (median age 16.4 years), the transjugular approach was used in 14 patients (17%). The transjugular group was younger (median age 11.9 versus 17.3 years), had lower body surface area (mean 1.33 versus 1.61 m2), more often had moderate or greater tricuspid regurgitation (29% versus 7%), and had a higher ratio of right ventricle-to-systemic systolic pressure (mean 82.4 versus 64.7). Patients requiring a transjugular approach after an unsuccessful transfemoral approach had longer fluoroscopic times and procedure duration. CONCLUSIONS: The transjugular approach for transcatheter pulmonary valve implantation is used infrequently but is more often used in younger and smaller patients. Technical limitations from a transfemoral approach may be anticipated if there is moderate or greater tricuspid regurgitation or higher right ventricular pressures. In these patients, a transjugular approach should be considered early.


Assuntos
Cardiopatias Congênitas/complicações , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Veias Jugulares/cirurgia , Valva Pulmonar/anormalidades , Valva Pulmonar/cirurgia , Adolescente , Criança , Ecocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência da Valva Tricúspide/epidemiologia , Adulto Jovem
18.
Catheter Cardiovasc Interv ; 85(2): 240-8, 2015 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24782400

RESUMO

OBJECTIVES: To describe a new technique for transcatheter patent ductus arteriosus (PDA) closure in extremely preterm infants using commercially available technology. BACKGROUND: PDA in premature neonates continues to be a significant clinical problem contributing importantly to both morbidity and mortality. Surgical ligation and medical therapy both have their drawbacks. MATERIAL AND METHODS: Hospital records and catheterization reports of all premature neonates (< 32 weeks gestation) who underwent transcatheter PDA closure between March 2013 and February 2014 were reviewed. Particular attention was paid to procedural details, complications, and short and mid-term outcomes. RESULTS: Six premature infants born at gestational ages ranging between 26 and 31 weeks (median, 26 weeks) underwent attempted transcatheter PDA closure using the Amplatzer Vascular Plug II (AVP II). Median age and weight was 21.5 days (16-80 days) and 1,180 g (870-2,240 g), respectively. Fluoroscopy and echocardiography were used to guide device. Contrast angiography was not used in any patient. Complete closure was achieved in all patients with no major procedural complications. Median fluoroscopy and procedural times were 9.4 (0-19.5) and 51.5 (33-87) min, respectively. All patients were alive at the time of this report. There were no instances of device migration, left pulmonary artery (LPA), or aortic coarctation. CONCLUSIONS: This preliminary study demonstrates that transcatheter PDA closure can be successfully performed in extremely preterm neonates using currently available technology with a high success rate and a low incidence of complications. This report also describes a novel transvenous approach using a combination of echocardiography and judicious use of fluoroscopy to avoid arterial access in this fragile patient population. © 2014 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/métodos , Permeabilidade do Canal Arterial/terapia , Lactente Extremamente Prematuro , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/diagnóstico , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Feminino , Fluoroscopia , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Masculino , Desenho de Prótese , Radiografia Intervencionista , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção
19.
Catheter Cardiovasc Interv ; 86(1): 85-93, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25809590

RESUMO

With the evolution of transcatheter valve replacement, an important opportunity has arisen for cardiologists and surgeons to collaborate in identifying the criteria for performing these procedures. Therefore, The Society for Cardiovascular Angiography and Interventions (SCAI), American Association for Thoracic Surgery (AATS), American College of Cardiology (ACC), and The Society of Thoracic Surgeons (STS) have partnered to provide recommendations for institutions to assess their potential for instituting and/or maintaining a transcatheter valve program. This article concerns transcatheter pulmonic valve replacement (tPVR). tPVR procedures are in their infancy with few reports available on which to base an expert consensus statement. Therefore, many of these recommendations are based on expert consensus and the few reports available. As the procedures evolve, technology advances, experience grows, and more data accumulate, there will certainly be a need to update this consensus statement. The writing committee and participating societies believe that the recommendations in this report serve as appropriate requisites. In some ways, these recommendations apply to institutions more than to individuals. There is a strong consensus that these new valve therapies are best performed using a Heart Team approach; thus, these credentialing criteria should be applied at the institutional level. Partnering societies used the ACC's policy on relationships with industry (RWI) and other entities to author this document (http://www.acc.org/guidelines/about-guidelines-and-clinical-documents). To avoid actual, potential, or perceived conflicts of interest due to industry relationships or personal interests, all members of the writing committee, as well as peer reviewers of the document, were asked to disclose all current healthcare-related relationships including those existing 12 months before the initiation of the writing effort. A committee of interventional cardiologists and surgeons was formed to include a majority of members with no relevant RWI and to be led by an interventional cardiology cochair and a surgical cochair with no relevant RWI. Authors with relevant RWI were not permitted to draft or vote on text or recommendations pertaining to their RWI. RWI were reviewed on all conference calls and updated as changes occurred. Author and peer reviewer RWI pertinent to this document are disclosed in the Appendices. In addition, to ensure complete transparency, authors' comprehensive disclosure information (including RWI not pertinent to this document) is available in Appendix AII. The work of the writing committee was supported exclusively by the partnering societies without commercial support. SCAI, AATS, ACC, and STS believe that adherence to these recommendations will maximize the chances that these therapies will become a successful part of the armamentarium for treating valvular heart disease in the United States. In addition, these recommendations will hopefully facilitate optimum quality during the delivery of this therapy, which will be important to the development and successful implementation of future, less invasive approaches to structural heart disease.


Assuntos
Cateterismo Cardíaco/normas , Cardiologia/normas , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/normas , Guias de Prática Clínica como Assunto , Valva Pulmonar/cirurgia , Sociedades Médicas , American Heart Association , Humanos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA