Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Chembiochem ; 24(19): e202300362, 2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37435783

RESUMO

Pyrazines are ubiquitous in nature - biosynthesized by microorganisms, insects, and plants. Due to their great structural diversity, they own manifold biological functions. Alkyl- and alkoxypyrazines for instance play a key role as semiochemicals, but also as important aroma compounds in foods. Especially 3-alkyl-2-methoxypyrazines (MPs) have been of great research interest. MPs are associated with green and earthy attributes. They are responsible for the distinctive aroma properties of numerous vegetables. Moreover, they have a strong influence on the aroma of wines, in which they are primarily grape-derived. Over the years various methods have been developed and implemented to analyse the distribution of MPs in plants. In addition, the biosynthetic pathway of MPs has always been of particular interest. Different pathways and precursors have been proposed and controversially discussed in the literature. While the identification of genes encoding O-methyltransferases gave important insights into the last step of MP-biosynthesis, earlier biosynthetic steps and precursors remained unknown. It was not until 2022 that in vivo feeding experiments with stable isotope labeled compounds revealed l-leucine and l-serine as important precursors for IBMP. This discovery gave evidence for a metabolic interface between the MP-biosynthesis and photorespiration.

2.
Chemistry ; 29(16): e202203674, 2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36548125

RESUMO

3-Isobutyl-2-methoxypyrazine (IBMP) is an extremely potent odorant and responsible for the specific aroma of many fruits and vegetables. Especially bell pepper contains high levels of IBMP, which is the character impact compound of its typical aroma. However, since the discovery of methoxypyrazines in plants in the 1960s the biosynthesis of their pyrazine ring motif remained so far unknown. Therefore, the biosynthetic pathway to IBMP was investigated by feeding experiments with stable-isotope labeled precursors. For the first time it could be shown that l-serine plays a key role in the pyrazine ring construction of 3-alkyl-2-methoxypyrazines (MPs). Based on HS-SPME-GCxGC-TOF-MS analysis, it is shown that the biosynthetic pathway to IBMP is closely linked to photorespiratory derived l-serine.


Assuntos
Capsicum , Capsicum/metabolismo , Frutas/química , Frutas/metabolismo , Pirazinas , Odorantes/análise
3.
Vascular ; 29(2): 207-212, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32731800

RESUMO

OBJECTIVES: The aim of this study was to report on the safety and feasibility of secondary relining with focal flaring of novel-generation balloon-expandable covered stents for endovascular treatment of significant diameter mismatch in the aorto-iliac territory. Significant diameter mismatch was defined as >20% difference in the nominal diameter between the intended proximal and distal landing zones. METHODS: Patient A was an 84-year-old man with prior abdominal aortic aneurysm open repair with a straight 20 mm Dacron tube. He presented with a right common iliac artery aneurysm (Ø88 mm) with contained rupture. The Gore Viabahn endoprosthesis (9 mm × 5 cm) was inserted proximally about 15 mm above the occluded ostium of the internal iliac artery. Subsequently, the BeGraft Aortic® (16 mm × 48 mm) was inserted proximally up to the common iliac artery origin; its proximal portion was flared to 22 mm. Patient B was a 77-year-old man with prior endovascular abdominal aortic aneurysm repair with a Medtronic Endurant stent-graft. He presented with occlusion of the right limb of the aortic endoprosthesis and thrombosis that extended down to the level of the superficial femoral artery. After mechanical thrombectomy, two Gore Viabahn endoprosthesis (first one, 8 mm × 10 cm; second one, 10 mm × 15 cm) were inserted into the right iliac limb. Subsequently, the BeGraft Aortic® (12mm × 39mm) was inserted proximally up to the gate of the aortic stent-graft; its proximal portion was flared to 16 mm. RESULTS: Technical success and clinical success were achieved in both patients. Imaging follow-up (6 months for Patient A, 12 months for Patient B) showed correct placement of all stent-grafts without any graft-related adverse event. The patients remained free from new reinterventions or recurrent symptoms. Patient A died 8 months after the index procedure from acute respiratory failure after community acquired pneumonia. CONCLUSION: Secondary relining with focal flaring of novel-generation balloon-expandable covered stents for endovascular treatment of significant diameter mismatch in the aorto-iliac territory is safe and feasible. Although mid-term results seem to be effective, longer follow-up is warranted to establish durability of the technique.


Assuntos
Aneurisma Roto/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aneurisma Ilíaco/cirurgia , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Evolução Fatal , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Masculino , Desenho de Prótese , Resultado do Tratamento
4.
Vasa ; 50(6): 453-461, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34102866

RESUMO

Background: The aim of this study was to assess the prognostic interaction between age and sex on peri-operative and follow-up outcomes following elective carotid endarterectomy (CEA) for asymptomatic and symptomatic carotid stenosis. Patients and methods: A retrospective review of all patients admitted to a single vascular unit who underwent elective CEA between January, 2015 and December, 2019 was performed. The primary endpoints of the study were overall survival (from index operation) and cumulative stroke rate at thirty days. Results: A total of 383 consecutive patients were included in this study; of these 254 (66.4%) were males. At baseline, males were younger (mean age 73.4±11 vs. 76.3±10 years, p=.01) and with lower proportion of octogenarians (20.4% vs. 28.7%, p=.05). The rate of stroke in symptomatic and asymptomatic patients (males vs. females) were as follows: a) whole cohort 1.9% vs. 2% (p=1.00) and 2.7% vs. 1.3% (p=.66), respectively; b) ≥80 years old 3.7% vs. 0% (p=1.00) and 4% vs. 5.9% (p=1.00), respectively; c) <80 years old 1.2% vs. 3.3% (p=.47) and 2.5% vs. 0% (p=.55), respectively. The 3-year survival estimates were significantly lower for males (84% vs. 92%, p=.03). After stratification by age groups, males maintained inferior survival rates in the strata aged <80 years (85% vs. 97%, p=.005), while no differences were seen in the strata aged ≥80 years (82% vs. 79%, p=.92). Using multivariate Cox proportional hazards, age (HR: 2.1, 95% CI: 1.29-3.3, p=.002) and male gender (HR: 2.5, 95% CI: 1.16-5.5, p=.02) were associated with increased hazards of all-cause mortality. Conclusions: In this study of elective CEA for asymptomatic and symptomatic carotid stenosis, similar peri-operative neurologic outcomes were found in both males and females irrespective of age. Despite being usually older, females have superior long-term survival rates.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
5.
Ann Vasc Surg ; 63: 99-107, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31449951

RESUMO

BACKGROUND: The aim of our article was to describe the complementary role of different technical solutions for secondary endovascular repair of recurring lesions and perioperative complications after open aortic repair (OAR). METHODS: We describe our clinical experience of secondary endovascular repair after OAR. We included in the analysis all consecutive patients who presented recurring lesions and perioperative complications after OAR and underwent secondary endovascular repair between January 1, 2015 and June 31, 2018. Both elective and nonelective cases were captured. Early end points were technical success, 30-day mortality, 30-day major adverse events, and 30-day vascular access complications. Late end points were survival and freedom from secondary interventions. RESULTS: Three different techniques were used in 6 patients: 2 cases of fenestrated-branched endovascular aortic repair (F-BEVAR), 2 cases of parallel-graft EVAR (pg-EVAR), and 2 cases of off-label use of standard devices. Technical success was 100%. One patient died within 30 days from acute pulmonary embolism. One patient developed acute kidney injury not requiring renal replacement therapy, whereas the remaining 4 patients were free from 30-day major adverse events. The cumulative rate of 30-day vascular access complications was 0%. All the 5 patients who survived the index hospitalization had ≥12 months of clinical and imaging follow-up. At the longest individual follow-up, they all were alive and free from secondary interventions. Computed tomography angiography showed in all cases sustained clinical success. CONCLUSIONS: Secondary endovascular repair of recurring lesions and perioperative complications after OAR is safe and feasible and offers a minimally invasive effective treatment option when a redo surgical operation would be associated with a considerable risk to the patient. Different solutions are available (including F-BEVAR, pg-EVAR, and off-label use of standard devices) and are complementary rather than competitive. Careful preoperative assessment and familiarity with advanced techniques are essential to achieve satisfactory outcomes.


Assuntos
Angioplastia com Balão , Aorta/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Complicações Pós-Operatórias/terapia , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Idoso , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Angioplastia com Balão/mortalidade , Aorta/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
6.
Ann Vasc Surg ; 66: 665.e9-665.e15, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31904516

RESUMO

PURPOSE: We present a novel application of custom-made stent grafts (CMSGs) with inner branches to incorporate target vessels (TVs) as an alternative to fenestrations or directional branches for secondary treatment after stent graft migration of previous infrarenal endovascular aortic repair (EVAR). CASE REPORT: Two consecutive patients with stent graft migration of previous EVAR were electively treated at our institution from January 1, 2018 through December 31, 2018. Stent graft migration was defined as radiologic evidence of stent graft displacement >10 mm. In both cases, a proximal type I endoleak was noted, and the residual infrarenal aorta above the previous endograft was unsuitable as the proximal landing zone for a nonfenestrated cuff. Repair was planned by means of a CMSG with 4 inner branches. The procedures were conducted in two-stage fashion to minimize the risk of spinal cord ischemia. The procedures were technically successful with a total of 8 TVs stented. Both patients did not suffer from any early (i.e., up to 30 days) major adverse events, and no access-site complications were noted. At one-year follow-up, computed tomography angiography showed regular placement of the CMSGs, widely patent TVs, absence of any type I or III endoleak, and stable sac size. No late reinterventions were recorded. CONCLUSIONS: Secondary treatment of stent graft migration after previous EVAR is safe and feasible using CSMGs with 4 inner branches. This technique is effective as showed by stable sac size and 100% freedom from TVI at mid-term imaging follow-up. Larger cohorts and longer follow-up are needed to confirm the preliminary results.


Assuntos
Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/cirurgia , Procedimentos Endovasculares/instrumentação , Migração de Corpo Estranho/cirurgia , Stents , Aorta/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Humanos , Desenho de Prótese , Reoperação , Resultado do Tratamento
7.
J Endovasc Ther ; 26(1): 128-132, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30499353

RESUMO

PURPOSE: To report an alternative approach for rescue of an occluded aortofemoral bypass using the Gore Excluder Iliac Branch Endoprosthesis (IBE). CASE REPORT: A 52-year-old man presented with acute right limb ischemia because of displaced and occluded iliac stents and was treated with aortofemoral bypass. On the third postoperative day, there was early bypass failure due to distal embolization from aortic thrombus. After fluoroscopy-guided balloon thrombectomy of the bypass, an endovascular bailout strategy was used. The Gore Excluder IBE was deployed below the renal arteries (with the external iliac limb opening in the surgical prosthesis and the gate opening within the aortic lumen). After antegrade catheterization of the gate, a Gore Viabahn endoprosthesis was inserted as the bridging endograft and deployed so that it landed just above the preimplanted aortoiliac kissing stents without overlapping them. Completion angiography showed technical success without complications; results were sustained at 1-year follow-up. CONCLUSION: The Gore Excluder IBE may represent a versatile solution for the rescue of complex cases when open surgery would be associated with a considerable risk. This off-label application of a well-recognized endovascular device is safe and feasible and may prove useful as a valuable alternative in properly selected patients.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Oclusão de Enxerto Vascular/cirurgia , Artéria Ilíaca/cirurgia , Trombose/cirurgia , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/fisiopatologia , Resultado do Tratamento , Grau de Desobstrução Vascular
8.
Ann Vasc Surg ; 59: 309.e5-309.e10, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30802571

RESUMO

The aortoaortic concept for endovascular repair (EVAR) of infrarenal abdominal aortic aneurysms (AAAs) is nearly forgotten but may constitute a valuable option for focal pathologies. Herein, we describe our experience using custom-made (CM) unibody conical endografts for saccular AAAs with narrow (≤20 mm wide) aortic bifurcation (AB) in three patients. Given the narrow AB, the option for a bifurcated stent graft was reputed not optimal. Therefore, we decided to further suggest the construction of a CM unibody conical stent graft with respect to unique anatomical characteristics of the patients. Technical success rate was 100%, and computed tomography angiography at first-month follow-up showed complete sealing proximally and distally with excellent conformability of the endografts in all the cases. All the patients were free from any-type endoleak (EL) and had no evidence of any endograft-related complication (i.e., fracture, thrombosis, or migration) or required any reintervention at their longest follow-up. We conclude that in the proper anatomic setting, the use of CM unibody conical endografts for elective EVAR of saccular AAAs with narrow AB is technically feasible with excellent short-term safety regarding ELs or migration.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Procedimentos Cirúrgicos Eletivos , Feminino , Humanos , Masculino , Desenho de Prótese , Resultado do Tratamento
9.
J Vasc Surg ; 67(6): 1727-1735, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29291905

RESUMO

OBJECTIVE: The objective of this study was to assess whether functional genetic polymorphisms of matrix metalloproteinases (MMPs) 1, 3, 9, and 12 are associated with arterial enlargements or aneurysms of the thoracic aorta or popliteal arteries in patients with abdominal aortic aneurysm (AAA). METHODS: The associations between MMP1 (-1607 G in/del, rs1799750), MMP3 (-1171 A in/del rs35068180), MMP9 (13-26 CA repeats around -90, rs2234681, rs917576, rs917577), and MMP12 (G/T missense variation, rs652438) polymorphisms and enlargements or aneurysms of the thoracic aorta and popliteal arteries were tested in 169 consecutive AAA patients. RESULTS: Thoracic aorta enlargement or aneurysm (TE/A; maximum diameter, >35 mm) was detected in 34 patients (20.1% prevalence). MMP9 rs2234681 microsatellite was the only genetic determinant of TE/A in AAA patients (P = .003), followed by hypercholesterolemia and antiplatelet use. Carriers of both alleles with ≥22 CA repeats had a 5.9 (95% confidence interval, 1.9-18.6; P < .0001) increased odds of TE/A, and a score considering all three variables showed 98% negative predictive value and 30% positive predictive value for thoracic aortic aneurysm detection. Eighty-two popliteal artery enlargements or aneurysms (diameter >10 mm) occurred in 55 patients (33.1% prevalence). Carriers of MMP12 rs652438 C allele showed an 18% (P = .006) increased diameter in popliteal arteries and a 2.8 (95% confidence interval, 1.3-6; P = .008) increased odds of popliteal artery enlargement or aneurysm compared with TT genotype. CONCLUSIONS: Among patients with AAA, carriers of homozygous ≥22 CA repeats in MMP9 rs12234681 and of C allele in MMP12 rs652438 have a substantial risk of carrying thoracic and popliteal enlargements, respectively.


Assuntos
Aneurisma da Aorta Abdominal/genética , Aneurisma da Aorta Torácica/genética , DNA/genética , Predisposição Genética para Doença , Metaloproteinases da Matriz/genética , Polimorfismo Genético , Artéria Poplítea , Idoso , Idoso de 80 Anos ou mais , Alelos , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/enzimologia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/enzimologia , Angiografia por Tomografia Computadorizada , Dilatação Patológica/diagnóstico , Dilatação Patológica/enzimologia , Dilatação Patológica/genética , Feminino , Variação Genética , Genótipo , Humanos , Masculino , Metaloproteinases da Matriz/metabolismo , Fatores de Risco
10.
Ann Vasc Surg ; 47: 260-265, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28943486

RESUMO

BACKGROUND: We sought to evaluate the midterm results of parallel-graft-endovascular aneurysm repair (pg-EVAR) for complex aortic anatomy in high-risk candidates for open surgical repair of abdominal aortic aneurism (AAA). METHODS: Clinical and radiographic information on 35 patients treated by pg-EVAR between March 2010 and December 2015 was retrospectively reviewed and analyzed. All patients presented with symptomatic aneurysms and were treated within 3 days of clinical presentation. Primary end points included primary chimney graft patency, overall survival, and freedom from all reintervention. RESULTS: Overall, 55 chimney grafts were placed into 47 renal arteries and 8 superior mesenteric arteries in 35 patients. An endurant stent graft was used as the main body component in all cases. At 36 months, primary chimney graft patency was 88%, overall survival of patients was 71%, and the rate of freedom from all reintervention was 78%. CONCLUSIONS: Considering our midterm results, pg-EVAR seems to be a safe and effective treatment for patients with complex anatomies and at poor risk for open repair.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Intervalo Livre de Doença , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Itália , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Retratamento , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
11.
Ann Vasc Surg ; 53: 273.e7-273.e11, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30092424

RESUMO

Subclavian artery aneurysms (SAAs) are rare but potentially life- and limb-threatening. We present the case of a 69-year-old man with a true right SAA; the vertebral artery branched off the aneurysm and was the dominant one. A hybrid (combined open surgical and endovascular) repair was performed; the vertebral artery was anastomosed end to side to the common carotid artery through a right supraclavicular incision, then using a percutaneous high brachial artery access, a covered stent was deployed to exclude the SSA. The procedure was technically successful, and computed tomography angiography at 24 months showed regular placement of the endograft with blood flow within it and absence of any endograft-related complication (i.e., stent fracture/thrombosis/displacement or any-type detectable endoleak). This hybrid treatment is safe and feasible with good midterm results and may represent a valuable, less invasive alternative to conventional open surgical approaches.


Assuntos
Aneurisma/cirurgia , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Stents , Artéria Subclávia/cirurgia , Artéria Vertebral/cirurgia , Idoso , Aneurisma/diagnóstico por imagem , Aneurisma/fisiopatologia , Velocidade do Fluxo Sanguíneo , Angiografia por Tomografia Computadorizada , Humanos , Masculino , Desenho de Prótese , Fluxo Sanguíneo Regional , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/fisiopatologia , Resultado do Tratamento , Artéria Vertebral/diagnóstico por imagem , Artéria Vertebral/fisiopatologia
12.
Ann Vasc Surg ; 51: 326.e17-326.e21, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29772314

RESUMO

BACKGROUND: Preservation of the residual hypogastric artery (HGA) in patients with previous endovascular aortic aneurysm repair (EVAR) may require complex operative strategies. We report an alternative technique to preserve the residual HGA with the Gore Excluder Iliac Branch endoprosthesis (IBE) in urgent situations. METHODS: We report the case of 2 high-risk patients (unfit for open surgery), with previous EVAR and exclusion of 1 HGA, treated in emergency setting. Both patients met the anatomical requirements for Gore IBE use. Due to lack of the native aortic bifurcation, we used a transaxillary approach to deploy a covered stent (Gore Viabahn) in the target HGA. RESULTS: Technical success was 100%. Computed tomography angiography at 30 days, 6 months, and 1 year showed regular placement of all endografts and patency of all residual HGAs without evidence of any endograft-related complication (i.e., stent fracture, stent thrombosis or stent displacement). There was not any detectable type 1, 2, or 3 endoleak at longest follow-up. CONCLUSIONS: Our case series shows the technical feasibility and the good results of this approach, which may prove useful when the native aortoiliac carrefour is no longer available. The procedure seems to be safe and effective, with optimal primary patency of the stent grafts, freedom from type 1, 2, and 3 endoleaks, and absence of pelvic ischemic complications.


Assuntos
Falso Aneurisma/cirurgia , Aneurisma Roto/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aneurisma Ilíaco/cirurgia , Pelve/irrigação sanguínea , Stents , Idoso , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/fisiopatologia , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/métodos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/métodos , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/fisiopatologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fluxo Sanguíneo Regional , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
13.
Ann Vasc Surg ; 38: 317.e1-317.e4, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27522972

RESUMO

Papillary fibroelastoma is the second most frequent primary tumor of the heart. We report the case of a cardiac papillary fibroelastoma, arising from the interatrial septum, symptomatic from distal embolization to lower limb arteries. Such a clinical presentation is extremely infrequent for cardiac papillary fibroelastomas. Moreover, the site of origin not from cardiac valves and the pathogenetic mechanism underlying the clinical manifestation both represent peculiar additional findings of our case.


Assuntos
Embolia/patologia , Fibroma/patologia , Neoplasias Cardíacas/patologia , Claudicação Intermitente/patologia , Extremidade Inferior/irrigação sanguínea , Células Neoplásicas Circulantes/patologia , Adulto , Biópsia , Embolia/etiologia , Embolia/cirurgia , Feminino , Fibroma/complicações , Átrios do Coração/patologia , Neoplasias Cardíacas/complicações , Humanos , Claudicação Intermitente/etiologia , Claudicação Intermitente/cirurgia , Resultado do Tratamento
14.
Ann Vasc Surg ; 38: 317.e9-317.e11, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27531081

RESUMO

We report the unusual case of a pseudoaneurysm of the superior gluteal artery (SGA) as a complication of a bone marrow biopsy. A 75-year-old man presented with pain and swelling of the left buttock 1 month after a bone marrow biopsy of the left iliac crest. The patient was treated by percutaneous ultrasound-guided thrombin injection (UGTI). The procedure was successful without any complication and the patient was discharged at home the same day. Follow-up at 3 months after the procedure confirmed the complete thrombosis of the pseudoaneurysm sac. At the best of our knowledge, UGTI of a pseudoaneurysm of the SGA has never been reported since now in the English literature.


Assuntos
Falso Aneurisma/terapia , Artérias , Biópsia/efeitos adversos , Exame de Medula Óssea/efeitos adversos , Nádegas/irrigação sanguínea , Doença Iatrogênica , Trombina/administração & dosagem , Ultrassonografia de Intervenção , Idoso , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Artérias/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Humanos , Injeções Intra-Arteriais , Masculino , Resultado do Tratamento
15.
Ann Vasc Surg ; 29(2): 361.e5-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25462549

RESUMO

Internal jugular vein hemangioma, also called pyogenic granuloma, is a rare tumor. Such a neoformation was accidentally discovered and excised in a middle-aged man. Histologic and immunohistochemical investigations were performed, and this case is compared with the poor amount of similar ones described in the literature.


Assuntos
Granuloma Piogênico/cirurgia , Veias Jugulares , Doenças Vasculares Periféricas/cirurgia , Granuloma Piogênico/diagnóstico por imagem , Humanos , Veias Jugulares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/diagnóstico por imagem , Ultrassonografia
16.
Phytochemistry ; 205: 113488, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36323357

RESUMO

The distribution and translocation as well as the biosynthetic sites of 3-isobutyl-2-methoxypyrazine (IBMP) in bell pepper plants (Capsicum annuum) were examined. For IBMP-quantification, a stable-isotope dilution assay (SIDA) was developed, using headspace solid-phase microextraction (HS-SPME) combined with gas chromatography and time-of-flight mass spectrometry (ToF-MS). While IBMP was the most abundant MP in all aerial plant parts, IPMP was dominating in root tissues. The highest IBMP-levels were found in unripe bell pepper fruits. Moreover, feeding experiments with [2H10]-l-leucine revealed that IBMP is biosynthesized in all plant parts, while in roots and ripe bell pepper fruit tissues no incorporation of the labelled precursor was detectable. A potential phloem translocation of IBMP could not be detected.


Assuntos
Capsicum
17.
J Agric Food Chem ; 70(22): 6719-6725, 2022 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-35621729

RESUMO

The biosynthesis of 3-isobutyl-2-methoxypyrazine (IBMP) in bell pepper fruits (Capsicum annuum L.) was investigated by in vivo feeding experiments with stable isotope-labeled precursors. Volatiles were extracted using headspace solid-phase microextraction (HS-SPME) and analyzed by comprehensive two-dimensional gas chromatography (GC×GC) coupled to a time-of-flight mass spectrometer (ToF-MS). Feeding experiments revealed incorporation of l-leucine and α-ketoisocaproic acid (α-KIC) as well as glycine and glyoxylic acid into IBMP. Furthermore, it has been shown that de novo biosynthesis of IBMP occurs in pericarp tissues of unripe bell pepper fruits, whereas pericarp tissues of ripe bell pepper fruits showed no capability of IBMP biosynthesis.


Assuntos
Capsicum , Capsicum/química , Frutas/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Marcação por Isótopo , Odorantes/análise , Pirazinas
18.
Cardiovasc Intervent Radiol ; 40(4): 616-620, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27928584

RESUMO

We report our experience with the urgent treatment of two high-risk patients with infected femoral artery pseudoaneurysms (IFAPs) with the placement of a self-expandable covered stent (SECS). In both cases, there was no perioperative mortality and the aneurysm exclusion was successful without early or late stent thrombosis/stent fracture nor acute or chronic limb ischemia or limb loss. There was no recurrence of local or systemic infection during the follow-up period. Endovascular therapy represents a feasible treatment option for IFAPs in those patients for whom the risk of open surgical repair would be prohibitive, especially under urgent circumstances.


Assuntos
Falso Aneurisma/cirurgia , Aneurisma Infectado/cirurgia , Procedimentos Endovasculares/métodos , Artéria Femoral/cirurgia , Stents , Adulto , Falso Aneurisma/microbiologia , Implante de Prótese Vascular/métodos , Artéria Femoral/microbiologia , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
19.
Int J Angiol ; 25(2): 93-8, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27231424

RESUMO

Genetic variants of matrix metalloproteases (MMPs)-1, -3, and 9, together with clinical variables, might predict the growth rate (GR) of abdominal aortic aneurysm (AAA). Genotyping of MMP-1 (-1,607 G+/G-), MMP-3 (- 1,171 6A/5A), and MMP-9 microsatellite (13-26 cytosine-adenosine repeats around -90) from peripheral blood was performed in 137 AAA patients with two AAA diameter measurements (at least 3 months to 1 year apart). When the same technique (either ultrasound or computed tomography) was used for the two measurements, yearly GR was estimated and compared with MMP genotype and clinical features by linear and binary logistic regression. Collectively, 36 patients provided 94 observations, with a median GR of 3 mm/year (interquartile range, 0-5.8); GRs in carriers of MMP-1 polymorphism G-/G-, G-/G+, and G+/G+ genotype were 0.3, 3.5, and 4.7mm/year, respectively (p = 0.008). In linear logistic regression, the main determinant of GR was growth arrest (GA, i.e., GR = 0, occurring in 32 observations, 34%). In turn, GA occurred mainly in G-/G- MMP-1 genotype (odds ratio, 3.9; 95% confidence interval, 1.6-9.7; p = 0.002), while variables accounting for GR > 0 were MMP-1 G + /G+ genotype, intake of any antihypertensive drug, and MMP-3 6A/6A genotype. Carriers of none, one, or two/three of these conditions accounted for a GR of 3, 4, and 9 mm/year, respectively (p = 0.001). MMP-1 (-1,607 G+/-) variant is associated to differential GR in AAA: homozygous G deletion variant shows higher GA prevalence and lower GR, while carriers of G + /G+ MMP-1 genotype, together with intake of antihypertensive drugs, and 6A/6A in MMP-3 present cumulative GR increase.

20.
Atherosclerosis ; 215(1): 153-9, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21232745

RESUMO

OBJECTIVE: To assess the association of matrix metalloproteinases (MMP) genetic polymorphism (PM) with plaques vulnerability and clinical outcome of acute vascular events. METHODS: MMP-1 (-1607 G in/del), MMP-3 (-1171 A in/del), and MMP-9 microsatellite ((13-26) CA repeats around -90) PMs have been determined (i) in 204 patients with cerebrovascular disease to assess the association with features of vulnerability in carotid plaques and prevalence of stroke, (ii) in 208 patients with UA/NSTEMI to assess the association with in-hospital clinical outcome. RESULTS: Plaques from carriers of MMP-1 G insertion showed significantly smaller plaques and thicker fibrous cap. In CVD patients carrying such variant, Odds Ratio for previous stroke was 0.27 (95%C.I. 0.13-0.56, P=0.0002) and, in UA/NSTEMI patients, the risk of Major Adverse Cardiac Events (MACE, persistent angina, NSTEMI, and vascular death) was 0.22 (95%C.I. 0.11-0.44, P<0.0001). No variants in MMP-3 PM were associated to differences in either plaque features or clinical outcome. Carriers of MMP-9≥22 repeats in the microsatellite had larger plaques and lipid core. In CVD patients with such variant, Odds Ratio for stroke was 2.2 (95%C.I. 1.1-4.4) and, in UA/NSTEMI patients, MACE risk was 4.1 (95%C.I. 2.3-7.4, P<0.0001). Persistent angina and NSTEMI separately provided comparable results. CONCLUSIONS: Carriers of MMP-1 G insertion show smaller and more stable plaques, as well as better prognosis in acute vascular events, while patients with ≥22 repeats in MMP-9 have larger necrotic core and worse prognosis in UA/NSTEMI.


Assuntos
Angina Instável/genética , Metaloproteinase 1 da Matriz/genética , Metaloproteinase 3 da Matriz/genética , Metaloproteinase 9 da Matriz/genética , Infarto do Miocárdio/genética , Placa Aterosclerótica/genética , Acidente Vascular Cerebral/genética , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/patologia , Polimorfismo Genético , Acidente Vascular Cerebral/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA