Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Emerg Infect Dis ; 30(1): 133-135, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38147030

RESUMO

A cluster of 3 persons in Germany experienced hantavirus disease with renal insufficiency. Reverse transcription PCR-based genotyping revealed infection by Seoul hantavirus transmitted from pet rats. Seoul virus could be responsible for disease clusters in Europe, and infected pet rats should be considered a health threat.


Assuntos
Orthohantavírus , Vírus de RNA , Vírus Seoul , Animais , Ratos , Vírus Seoul/genética , Hotspot de Doença , Alemanha/epidemiologia , Europa (Continente)
2.
Methods ; 201: 34-40, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-33722693

RESUMO

Viral load monitoring in human immunodeficiency virus type 1 (HIV-1) infection is often performed using reverse transcription quantitative PCR (RT-qPCR) to observe response to treatment and identify the development of resistance. Traceability is achieved using a calibration hierarchy traceable to the International Unit (IU). IU values are determined using consensus agreement derived from estimations by different laboratories. Such a consensus approach is necessary due to the fact that there are currently no reference measurement procedures available that can independently assign a reference value to viral reference materials for molecular in vitro diagnostic tests. Digital PCR (dPCR) is a technique that has the potential to be used for this purpose. In this paper, we investigate the ability of reverse transcriptase dPCR (RT-dPCR) to quantify HIV-1 genomic RNA without calibration. Criteria investigated included the performance of HIV-1 RNA extraction steps, choice of reverse transcription approach and selection of target gene with assays performed in both single and duplex format. We developed a protocol which was subsequently applied by two independent laboratories as part of an external quality assurance (EQA) scheme for HIV-1 genome detection. Our findings suggest that RT-dPCR could be used as reference measurement procedure to aid the value assignment of HIV-1 reference materials to support routine calibration of HIV-1 viral load testing by RT-qPCR.


Assuntos
HIV-1 , Transcrição Reversa , HIV-1/genética , Humanos , RNA , RNA Viral/análise , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa
3.
Methods ; 201: 65-73, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-33812016

RESUMO

A candidate digital PCR (dPCR)-based reference measurement procedure for quantification of human cytomegalovirus (hCMV) was evaluated in 10 viral load comparison schemes (seven external quality assessment (EQA) and three additional training schemes) organized by INSTAND e.V. over four years (between September 2014 and March 2018). Four metrology institutes participated in these schemes using the same extraction method and dPCR measurement procedure for the hCMV specific target sequence of UL54 gene. The calibration independent reference measurement procedure results from the metrology institutes were compared to the results of the clinical diagnostic laboratories applying hCMV qPCR measurement procedures calibrated to reference materials. While the criteria for the acceptable deviation from the target value interval for INSTAND's EQA schemes is from -0.8 log10 to +0.8 log10, the majority of dPCR results were between -0.2 log10 to +0.2 log10. Only 4 out of 45 results exceeded this interval with the maximum deviation of -0.542 log10. In the training schemes containing samples with lower hCMV concentrations, more than half of the results deviated less than ±0.2 log10 from the target value, while more than 95% deviated less than ±0.4 log10 from the target value. Evaluation of intra- and inter-laboratory variation of dPCR results confirmed high reproducibility and trueness of the method. This work demonstrates that dPCR has the potential to act as a calibration independent reference measurement procedure for the value assignment of hCMV calibration and reference materials to support qPCR calibration as well as ultimately for routine hCMV load testing.


Assuntos
Citomegalovirus , Calibragem , Citomegalovirus/genética , Humanos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reprodutibilidade dos Testes
4.
Clin Chem ; 68(1): 153-162, 2021 12 30.
Artigo em Inglês | MEDLINE | ID: mdl-34633030

RESUMO

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA quantities, measured by reverse transcription quantitative PCR (RT-qPCR), have been proposed to stratify clinical risk or determine analytical performance targets. We investigated reproducibility and how setting diagnostic cutoffs altered the clinical sensitivity of coronavirus disease 2019 (COVID-19) testing. METHODS: Quantitative SARS-CoV-2 RNA distributions [quantification cycle (Cq) and copies/mL] from more than 6000 patients from 3 clinical laboratories in United Kingdom, Belgium, and the Republic of Korea were analyzed. Impact of Cq cutoffs on clinical sensitivity was assessed. The June/July 2020 INSTAND external quality assessment scheme SARS-CoV-2 materials were used to estimate laboratory reported copies/mL and to estimate the variation in copies/mL for a given Cq. RESULTS: When the WHO-suggested Cq cutoff of 25 was applied, the clinical sensitivity dropped to about 16%. Clinical sensitivity also dropped to about 27% when a simulated limit of detection of 106 copies/mL was applied. The interlaboratory variation for a given Cq value was >1000 fold in copies/mL (99% CI). CONCLUSION: While RT-qPCR has been instrumental in the response to COVID-19, we recommend Cq (cycle threshold or crossing point) values not be used to set clinical cutoffs or diagnostic performance targets due to poor interlaboratory reproducibility; calibrated copy-based units (used elsewhere in virology) offer more reproducible alternatives. We also report a phenomenon where diagnostic performance may change relative to the effective reproduction number. Our findings indicate that the disparities between patient populations across time are an important consideration when evaluating or deploying diagnostic tests. This is especially relevant to the emergency situation of an evolving pandemic.


Assuntos
Teste de Ácido Nucleico para COVID-19/normas , COVID-19 , Ácidos Nucleicos , Bélgica , COVID-19/diagnóstico , Humanos , Ácidos Nucleicos/análise , RNA Viral/análise , Reprodutibilidade dos Testes , República da Coreia , SARS-CoV-2 , Sensibilidade e Especificidade , Reino Unido
5.
Transfusion ; 60(10): 2441-2447, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32627200

RESUMO

BACKGROUND: In the pandemic, testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by real-time polymerase chain reaction is one of the pillars on which countermeasures are based. Factors limiting the output of laboratories interfere with the effectiveness of public health measures. Conserving reagents by pooling samples in low-probability settings is proposed but may cause dilution and loss of sensitivity. Blood transfusion services had experience in performance of high throughput nucleic acid testing (NAT) analysis and can support the national health system by screening of the inhabitants for SARS-COV-2. METHODS: We evaluated a new approach of a multiple-swab method by simultaneously incubating multiple respiratory swabs in a single tube. Analytical sensitivity was constant up to a total number of 50 swabs. It was consequently applied in the testing of 50 symptomatic patients (5-sample pools) as well as 100 asymptomatic residents of a nursing home (10-sample pools). RESULTS: The novel method did not cause false-negative results with nonsignificantly differing cycle threshold values between single-swab and multiple-swab NAT. In two routine applications, all minipools containing positive patient samples were correctly identified. CONCLUSIONS: The new method enables countries to increase the total number of testing significantly. The multiple-swab method is able to screen system relevant groups of employees frequently. The example in Germany shows that blood transfusion services can support general health systems with their experience in NAT and their high-throughput instruments. Screening of a huge number of inhabitants is currently the only option to prevent a second infection wave and enable exit strategies in many countries.


Assuntos
SARS-CoV-2/patogenicidade , COVID-19/virologia , Alemanha , Humanos , Técnicas de Amplificação de Ácido Nucleico/métodos , Manejo de Espécimes/métodos
6.
J Infect Dis ; 211(4): 613-22, 2015 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-25193982

RESUMO

BACKGROUND: Coxsackievirus B3 (CVB3) is a major heart pathogen against which no therapy exists to date. The potential of a combination treatment consisting of a proteinaceous virus receptor trap and an RNA interference-based component to prevent CVB3-induced myocarditis was investigated. METHODS AND RESULTS: A soluble variant of the extracellular domain of the coxsackievirus-adenovirus receptor (sCAR-Fc) was expressed from an adenoviral vector and 2 short hairpin RNAs (shRdRp2.4) directed against CVB3 were delivered by an adeno-associated virus (AAV) vector. Cell culture experiments revealed additive antiviral activity of the combined application. In a CVB3-induced mouse myocarditis model, both components applied individually significantly reduced inflammation and viral load in the heart. The combination exerted an additive antiviral effect and reduced heart pathology. Hemodynamic measurement revealed that infection with CVB3 resulted in impaired heart function, as illustrated by a drastically reduced cardiac output and impaired contractility and relaxation. Treatment with either sCAR-Fc or shRdRp2.4 significantly improved these parameters. Importantly, the combination of both components led to a further significant improvement of heart function. CONCLUSIONS: Combination of sCAR-Fc and shRdRp2.4 exerted additive effects and was significantly more effective than either of the single treatments in inhibiting CVB3-induced myocarditis and preventing cardiac dysfunction.


Assuntos
Antivirais/farmacologia , Infecções por Coxsackievirus/tratamento farmacológico , Enterovirus Humano B/efeitos dos fármacos , Terapia Genética/métodos , Miocardite/tratamento farmacológico , Interferência de RNA , Animais , Antivirais/metabolismo , Infecções por Coxsackievirus/virologia , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Células HeLa , Humanos , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Miocardite/virologia , RNA Interferente Pequeno/genética , RNA Interferente Pequeno/metabolismo , Receptores Virais/genética , Receptores Virais/metabolismo , Carga Viral/efeitos dos fármacos
7.
J Clin Microbiol ; 53(7): 2008-14, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25392365

RESUMO

Nucleic acid-based tests for infectious diseases currently used in the clinical laboratory and in point-of-care devices are diverse. Measurement challenges associated with standardization of quantitative viral load testing are discussed in relation to human cytomegalovirus, BK virus, and Epstein-Barr virus, while the importance of defining the performance of qualitative methods is illustrated with Mycobacterium tuberculosis and influenza virus. The development of certified reference materials whose values are traceable to higher-order standards and reference measurement procedures, using, for instance, digital PCR, will further contribute to the understanding of analytical performance characteristics and promote clinical data comparability.


Assuntos
Bactérias/isolamento & purificação , Carga Bacteriana/normas , Técnicas de Diagnóstico Molecular/normas , Carga Viral/normas , Vírus/isolamento & purificação , Infecções Bacterianas/microbiologia , Carga Bacteriana/métodos , Humanos , Técnicas de Diagnóstico Molecular/métodos , Padrões de Referência , Carga Viral/métodos , Viroses/virologia
8.
Int J Med Microbiol ; 305(7): 607-11, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26342877

RESUMO

Hantavirus infections in Germany appear periodically with peak numbers every 2-3 years. The reported cases in the years 2007, 2010 and 2012 exceeded many times over those in the years in-between. In order to reveal faults of certain in vitro diagnostic assays (IVDs), to harmonize the performances of the individual assays and to improve the users' competence in interpreting the results, the National Consiliary Laboratory for Hantaviruses and INSTAND e.V. (Society for Promoting Quality Assurance in Medical Laboratories e.V.) established an external quality assessment (EQA) scheme for proficiency testing of hantavirus serodiagnostics. The first EQA scheme (pilot study) started in March 2009 with 58 participating laboratories from Germany and neighboring countries. Twice a year four serum samples were sent out to the participants to investigate whether the sample reflects an acute or past infection and to distinguish between infections with the hantavirus types Puumala virus (PUUV) and Dobrava-Belgrade virus (DOBV), both endemic in Central Europe. In addition, samples negative for anti-hantavirus antibodies were tested in order to examine the specificity of the IVDs applied in the participating laboratories. An increasing number of laboratories participated, with a maximum of 92 in March 2014. When summarizing in total 2592 test results, the laboratories reached an overall specificity of 96.7% and a sensitivity of 95% in their detection of a hantavirus infection. A correct distinction between acute and past infections was forwarded in 90-96% of replies of laboratories. Exact serotyping (PUUV vs. DOBV) of the infection was reported in 81-96% of replies with the lowest accuracy for past DOBV infections; cross-reactivities between diagnostic antigens of the two viruses as well as persistent IgM titers in humans may interfere with exact testing. The EQAs revealed acceptable results for the serodiagnostic of hantavirus infection including serotyping but further improvement is still needed.


Assuntos
Infecções por Hantavirus/diagnóstico , Pesquisa sobre Serviços de Saúde , Ensaio de Proficiência Laboratorial/métodos , Ensaio de Proficiência Laboratorial/organização & administração , Testes Sorológicos/métodos , Europa (Continente) , Humanos , Sensibilidade e Especificidade
10.
BMC Res Notes ; 16(1): 210, 2023 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-37697348

RESUMO

OBJECTIVE: In routine clinical laboratories, severe acute respiratory syndrome coronavirus (SARS-CoV-2) infection is determined by reverse-transcription PCR (RT-PCR). In the COVID pandemic, a wide range of antigen detection tests were also in high demand. We investigated the correlation between SARS-CoV-2 NCap antigen and N gene concentration by analyzing samples from several INSTAND external quality assessment (EQA) schemes starting in March 2021. The absolute N gene concentration was measured using reverse transcriptase digital PCR (RT-dPCR) as reference value. Moreover, the performance of five commercial ELISA tests using an EQA inactivated SARS-CoV-2 sample at different concentrations was assessed on the basis of these reference values. RESULTS: Quantitative ELISA and RT-dPCR results showed a good correlation between SARS-CoV-2 NCap antigen and RNA concentration, but this correlation varies among SARS-CoV-2 isolates. A direct correlation between SARS-CoV-2 NCap antigen concentration and genome concentration should not be generally assumed. CONCLUSION: Further correlation studies between SARS-CoV-2 RNA and NCap antigen concentrations are needed, particularly in clinical samples and for emerging SARS-CoV-2 variants, to support the monitoring and improvement of antigen testing.


Assuntos
COVID-19 , RNA Viral , Humanos , RNA Viral/genética , SARS-CoV-2/genética , COVID-19/diagnóstico , Nucleocapsídeo
11.
PLoS One ; 18(4): e0285203, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37115793

RESUMO

BACKGROUND: In May 2022, the monkeypox virus (MPXV) spread into non-endemic countries and the global community was quick to test the lessons learned from the SARS-CoV-2 pandemic. Due to its symptomatic resemblance to other diseases, like the non-pox virus varicella zoster (chickenpox), polymerase chain reaction methods play an important role in correctly diagnosing the rash-causing pathogen. INSTAND quickly established a new external quality assessment (EQA) scheme for MPXV and orthopoxvirus (OPXV) DNA detection to assess the current performance quality of the laboratory tests. METHODS: We analyzed quantitative and qualitative data of the first German EQA for MPXV and OPXV DNA detection. The survey included one negative and three MPXV-positive samples with different MPX viral loads. The threshold cycle (Ct) or other measures defining the quantification cycle (Cq) were analyzed in an assay-specific manner. A Passing Bablok fit was used to investigate the performance at laboratory level. RESULTS: 141 qualitative datasets were reported by 131 laboratories for MPXV detection and 68 qualitative datasets by 65 laboratories for OPXV detection. More than 96% of the results were correctly identified as negative and more than 97% correctly identified as positive. An analysis of the reported Ct/Cq values showed a large spread of these values of up to 12 Ct/Cq. Nevertheless, there is a good correlation of results for the different MPXV concentrations at laboratory level. Only a few quantitative results in copies/mL were reported (MPXV: N = 5; OPXV: N = 2), but the results correlated well with the concentration differences between the EQA samples, which were to a power of ten each. CONCLUSION: The EQA results show that laboratories performed well in detecting both MPXV and OPXV. However, Ct/Cq values should be interpreted with caution when conclusions are drawn about the viral load as long as metrological traceability is not granted.


Assuntos
COVID-19 , Mpox , Orthopoxvirus , Humanos , Monkeypox virus/genética , SARS-CoV-2/genética
12.
J Clin Virol ; 165: 105521, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37302248

RESUMO

BACKGROUND: European legislation defines as "near-patient testing" (NPT) what is popularly and in other legislations specified as "point-of-care testing" (POCT). Systems intended for NPT/POCT use must be characterized by independence from operator activities during the analytic procedure. However, tools for evaluating this are lacking. We hypothesized that the variability of measurement results obtained from identical samples with a larger number of identical devices by different operators, expressed as the method-specific reproducibility of measurement results reported in External Quality Assessment (EQA) schemes, is an indicator for this characteristic. MATERIALS AND METHODS: Legal frameworks in the EU, the USA and Australia were evaluated about their requirements for NPT/POCT. EQA reproducibility of seven SARS-CoV-2-NAAT systems, all but one designated as "POCT", was calculated from variabilities in Ct values obtained from the respective device types in three different EQA schemes for virus genome detection. RESULTS: A matrix for characterizing test systems based on their technical complexity and the required operator competence was derived from requirements of the European In Vitro Diagnostic Regulation (IVDR) 2017/746. Good EQA reproducibility of the measurement results of the test systems investigated implies that different users in different locations have no recognizable influence on their measurement results. CONCLUSION: The fundamental suitability of test systems for NPT/POCT use according to IVDR can be easily verified using the evaluation matrix presented. EQA reproducibility is a specific characteristic indicating independence from operator activities of NPT/POCT assays. EQA reproducibility of other systems than those investigated here remains to be determined.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Reprodutibilidade dos Testes , COVID-19/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Técnicas de Amplificação de Ácido Nucleico
13.
Lancet Microbe ; 4(7): e552-e562, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37156257

RESUMO

During an epidemic, individual test results form the basis of epidemiological indicators such as case numbers or incidence. Therefore, the accuracy of measures derived from these indicators depends on the reliability of individual results. In the COVID-19 pandemic, monitoring and evaluating the performance of the unprecedented number of testing facilities in operation, and novel testing systems in use, was urgently needed. External quality assessment (EQA) schemes are unique sources of data reporting on testing performance, and their providers are recognised contacts and support for test facilities (for technical-analytical topics) and health authorities (for planning the monitoring of infection diagnostics). To identify information provided by SARS-CoV-2 genome detection EQA schemes that is relevant for public health microbiology, we reviewed the current literature published in PubMed between January, 2020, and July, 2022. We derived recommendations for EQA providers and their schemes for best practices to monitor pathogen-detection performance in future epidemics. We also showed laboratories, test facilities, and health authorities the information and benefits they can derive from EQA data, and from the non-EQA services of their providers.


Assuntos
COVID-19 , Pandemias , Humanos , Reprodutibilidade dos Testes , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/epidemiologia , Laboratórios
14.
Sci Rep ; 13(1): 13206, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37580353

RESUMO

The COVID-19 pandemic illustrated the important role of diagnostic tests, including lateral flow tests (LFTs), in identifying patients and their contacts to slow the spread of infections. INSTAND performed external quality assessments (EQA) for SARS-CoV-2 antigen detection with lyophilized and chemically inactivated cell culture supernatant of SARS-CoV-2 infected Vero cells. A pre-study demonstrated the suitability of the material. Participants reported qualitative and/or quantitative antigen results using either LFTs or automated immunoassays for five EQA samples per survey. 711 data sets were reported for LFT detection in three surveys in 2021. This evaluation focused on the analytical sensitivity of different LFTs and automated immunoassays. The inter-laboratory results showed at least 94% correct results for non-variant of concern (VOC) SARS-CoV-2 antigen detection for viral loads of ≥ 4.75 × 106 copies/mL and SARS-CoV-2 negative samples. Up to 85% had success for a non-VOC viral load of ~ 1.60 × 106 copies/mL. A viral load of ~ 1.42 × 107 copies/mL of the Delta VOC was reported positive in > 96% of results. A high specificity was found with almost 100% negative SARS-CoV-2 antigen results for HCoV 229E and HCoV NL63 positive samples. Quantitative results correlated with increasing SARS-CoV-2 viral load but showed a broad scatter. This study shows promising SARS-CoV-2 antigen test performance of the participating laboratories, but further investigations with the now predominant Omicron VOC are needed.


Assuntos
COVID-19 , SARS-CoV-2 , Chlorocebus aethiops , Animais , Humanos , Pandemias , Células Vero , COVID-19/diagnóstico , COVID-19/epidemiologia , Testes Imunológicos , Sensibilidade e Especificidade
15.
Lab Invest ; 92(1): 125-34, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21968812

RESUMO

Well-established differences in Coxsackievirus B3 (CVB3) elimination in resistant C57BL/6 and permissive A.SW/SnJ mice provide suitable models for studying the significance of the link between mitochondrial respiratory chain (RC), antioxidative stress components and mitochondrion-related apoptosis in the context of myocardial virus elimination. Distinct myocardial CVB3 titer in C57BL/6 (2.5 ± 1.4 × 10(4) plaque-forming units (p.f.u.)/g tissue) and A.SW/SnJ mice (1.4 ± 0.8 × 10(7) p.f.u./g) were associated with differences in the cardiac mitochondrial function 8 days post infection (p.i.). Infected C57BL/6 mouse hearts disclosed increased complex I (CI) and CIII activity, but restricted CII and normal CIV activity of RC. Reduced expression of the antioxidative catalase was accompanied by elevated lipid peroxidation (LPO), indicating oxidative stress. Intrinsic apoptosis was activated demonstrated by elevated levels of Bax, Bcl-2, caspase 3 and DNA degradation. In contrast, all myocardial RC complex activities were restricted in CVB3-infected A.SW/SnJ mice. The antioxidative system provided sufficient protection against oxidative stress shown by an elevated catalase expression and unaltered LPO. Bax and Bcl-2 levels were unchanged in CVB3-infected A.SW/SnJ mice, while caspase 3 was moderately increased but no DNA degradation was detectable. Correlation analyses including data from the two mouse strains revealed that reduced CVB3 titer correlated with increased CI and CIII activity, oxidative stress as well as active apoptosis during acute myocarditis (MC). C57BL/6 mice completely eliminated CVB3 and inflammation and normalized all intracellular parameters, while A.SW/SnJ mice showed permanently restricted CI activity in chronic MC 90 days p.i., at which time the replicating virus was no longer detectable but immunological processes were still active. Consequently, the regulation of energy metabolism appears crucial for an effective virus elimination and may be of prognostic and therapeutic significance for patients with virus-induced MC.


Assuntos
Infecções por Coxsackievirus/imunologia , Transporte de Elétrons/fisiologia , Enterovirus Humano B , Mitocôndrias Cardíacas/fisiologia , Miocardite/imunologia , Animais , Apoptose , Resistência à Doença , Complexo I de Transporte de Elétrons/fisiologia , Coração/virologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Estresse Oxidativo , Carga Viral
16.
J Virol ; 85(24): 13409-19, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21976640

RESUMO

Coevolution of virus and host is a process that emerges in persistent virus infections. Here we studied the coevolutionary development of coxsackievirus B3 (CVB3) and cardiac myocytes representing the major target cells of CVB3 in the heart in a newly established persistently CVB3-infected murine cardiac myocyte cell line, HL-1(CVB3). CVB3 persistence in HL-1(CVB3) cells represented a typical carrier-state infection with high levels (10(6) to 10(8) PFU/ml) of infectious virus produced from only a small proportion (approximately 10%) of infected cells. CVB3 persistence was characterized by the evolution of a CVB3 variant (CVB3-HL1) that displayed strongly increased cytotoxicity in the naive HL-1 cell line and showed increased replication rates in cultured primary cardiac myocytes of mouse, rat, and naive HL-1 cells in vitro, whereas it was unable to establish murine cardiac infection in vivo. Resistance of HL-1(CVB3) cells to CVB3-HL1 was associated with reduction of coxsackievirus and adenovirus receptor (CAR) expression. Decreasing host cell CAR expression was partially overcome by the CVB3-HL1 variant through CAR-independent entry into resistant cells. Moreover, CVB3-HL1 conserved the ability to infect cells via CAR. The employment of a soluble CAR variant resulted in the complete cure of HL-1(CVB3) cells with respect to the adapted virus. In conclusion, this is the first report of a CVB3 carrier-state infection in a cardiomyocyte cell line, revealing natural coevolution of CAR downregulation with CAR-independent viral entry in resistant host cells as an important mechanism of induction of CVB3 persistence.


Assuntos
Evolução Biológica , Enterovirus Humano B/crescimento & desenvolvimento , Enterovirus Humano B/genética , Miócitos Cardíacos/virologia , Animais , Sobrevivência Celular , Células Cultivadas , Infecções por Coxsackievirus/patologia , Infecções por Coxsackievirus/virologia , Enterovirus Humano B/patogenicidade , Humanos , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Ratos , Virulência
17.
J Infect Public Health ; 15(2): 203-209, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35038668

RESUMO

BACKGROUND: Emerging infectious diseases pose an increasing threat to all nations around the world, including to developed countries. By definition, because they are rare or unknown, public health systems are not well prepared against these emerging diseases. To be fully prepared, countries must have implemented surveillance systems to monitor rare or unusual sanitary events. METHODS: The capacity of diagnostic laboratories is a key component of surveillance systems since they are in charge of identifying the pathogens responsible for outbreaks in a timely manner. The MediLabSecure project aims at implementing a comprehensive surveillance system for vector-borne diseases around the Mediterranean and Black Sea regions. From 2014 to 2018, the human-virology group of MediLabSecure notably supported the implementation of molecular diagnostic capacities for eight arboviruses and one coronavirus in 19 laboratories of its network through sharing of protocols and reagents, and technical training of the scientific staff of beneficiary laboratories. RESULTS: We report the results of External Quality Assessments for four of these viruses to assess the efficiency of the diagnostic for these threats emerging in the geographic area. The results for these EQA demonstrate the success of the project in the implementation of diagnostic technics for the identification of Dengue, Chikungunya, Zika, and West Niles viruses in laboratories that did not have the capacity before. However, results also show that some work is still to be done to strengthen the newly acquired capacity. CONCLUSION: The MediLabSecure project deployed an effort to build an efficient capacity in identifying and survey the emergence of arboviruses in the Mediterranean area. Diagnostic technics were successfully implemented in many of the laboratories of the network, but the effort must be maintained over time to strengthen these capacities.


Assuntos
Infecções por Arbovirus , Arbovírus , Febre de Chikungunya , Infecção por Zika virus , Zika virus , Infecções por Arbovirus/diagnóstico , Infecções por Arbovirus/epidemiologia , Humanos
18.
Front Microbiol ; 13: 893801, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35707164

RESUMO

Background: There is an urgent need for harmonization between severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serology platforms and assays prior to defining appropriate correlates of protection and as well inform the development of new rapid diagnostic tests that can be used for serosurveillance as new variants of concern (VOC) emerge. We compared multiple SARS-CoV-2 serology reference materials to the WHO International Standard (WHO IS) to determine their utility as secondary standards, using an international network of laboratories with high-throughput quantitative serology assays. This enabled the comparison of quantitative results between multiple serology platforms. Methods: Between April and December 2020, 13 well-characterized and validated SARS-CoV-2 serology reference materials were recruited from six different providers to qualify as secondary standards to the WHO IS. All the samples were tested in parallel with the National Institute for Biological Standards and Control (NIBSC) 20/136 and parallel-line assays were used to calculate the relevant potency and binding antibody units. Results: All the samples saw varying levels of concordance between diagnostic methods at specific antigen-antibody combinations. Seven of the 12 candidate materials had high concordance for the spike-immunoglobulin G (IgG) analyte [percent coefficient of variation (%CV) between 5 and 44%]. Conclusion: Despite some concordance between laboratories, qualification of secondary materials to the WHO IS using arbitrary international units or binding antibody units per milliliter (BAU/ml) does not provide any benefit to the reference materials overall, due to the lack of consistent agreeable international unit (IU) or BAU/ml conversions between laboratories. Secondary standards should be qualified to well-characterized reference materials, such as the WHO IS, using serology assays that are similar to the ones used for the original characterization of the WHO IS.

19.
PLoS One ; 17(1): e0262656, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35051208

RESUMO

SARS-CoV-2, the cause of COVID-19, requires reliable diagnostic methods to track the circulation of this virus. Following the development of RT-qPCR methods to meet this diagnostic need in January 2020, it became clear from interlaboratory studies that the reported Ct values obtained for the different laboratories showed high variability. Despite this the Ct values were explored as a quantitative cut off to aid clinical decisions based on viral load. Consequently, there was a need to introduce standards to support estimation of SARS-CoV-2 viral load in diagnostic specimens. In a collaborative study, INSTAND established two reference materials (RMs) containing heat-inactivated SARS-CoV-2 with SARS-CoV-2 RNA loads of ~107 copies/mL (RM 1) and ~106 copies/mL (RM 2), respectively. Quantification was performed by RT-qPCR using synthetic SARS-CoV-2 RNA standards and digital PCR. Between November 2020 and February 2021, German laboratories were invited to use the two RMs to anchor their Ct values measured in routine diagnostic specimens, with the Ct values of the two RMs. A total of 305 laboratories in Germany were supplied with RM 1 and RM 2. The laboratories were requested to report their measured Ct values together with details on the PCR method they used to INSTAND. This resultant 1,109 data sets were differentiated by test system and targeted gene region. Our findings demonstrate that an indispensable prerequisite for linking Ct values to SARS-CoV-2 viral loads is that they are treated as being unique to an individual laboratory. For this reason, clinical guidance based on viral loads should not cite Ct values. The RMs described were a suitable tool to determine the specific laboratory Ct for a given viral load. Furthermore, as Ct values can also vary between runs when using the same instrument, such RMs could be used as run controls to ensure reproducibility of the quantitative measurements.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Testes Diagnósticos de Rotina/métodos , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , SARS-CoV-2/genética , Carga Viral/métodos , COVID-19/epidemiologia , COVID-19/virologia , Genes Virais , Alemanha/epidemiologia , Humanos , Reprodutibilidade dos Testes
20.
Circulation ; 120(23): 2358-66, 2009 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-19933937

RESUMO

BACKGROUND: Group B coxsackieviruses (CVBs) are the prototypical agents of acute myocarditis and chronic dilated cardiomyopathy, but an effective targeted therapy is still not available. Here, we analyze the therapeutic potential of a soluble (s) virus receptor molecule against CVB3 myocarditis using a gene therapy approach. METHODS AND RESULTS: We generated an inducible adenoviral vector (AdG12) for strict drug-dependent delivery of sCAR-Fc, a fusion protein composed of the coxsackievirus-adenovirus receptor (CAR) extracellular domains and the carboxyl terminus of human IgG1-Fc. Decoy receptor expression was strictly doxycycline dependent, with no expression in the absence of an inducer. CVB3 infection of HeLa cells was efficiently blocked by supernatant from AdG12-transduced cells, but only in the presence of doxycycline. After liver-specific transfer, AdG12 (plus doxycycline) significantly improved cardiac contractility and diastolic relaxation compared with a control vector in CVB3-infected mice if sCAR-Fc was induced before infection (left ventricular pressure 59+/-3.8 versus 45.4+/-2.7 mm Hg, median 59 versus 45.8 mm Hg, P<0.01; dP/dt(max) 3645.1+/-443.6 versus 2057.9+/-490.2 mm Hg/s, median 3526.6 versus 2072 mm Hg/s, P<0.01; and dP/dt(min) -2125.5+/-330.5 versus -1310.2+/-330.3 mm Hg/s, median -2083.7 versus -1295.9 mm Hg/s, P<0.01) and improved contractility if induced concomitantly with infection (left ventricular pressure 76.4+/-19.2 versus 56.8+/-10.3 mm Hg, median 74.8 versus 54.4 mm Hg, P<0.05; dP/dt(max) 5214.2+/-1786.2 versus 3011.6+/-918.3 mm Hg/s, median 5182.1 versus 3106.6 mm Hg/s, P<0.05), respectively. Importantly, hemodynamics of animals treated with AdG12 (plus doxycycline) were similar to uninfected controls. Preinfection induction of sCAR-Fc completely blocked and concomitant induction strongly reduced cardiac CVB3 infection, myocardial injury, and inflammation. CONCLUSIONS: AdG12-mediated sCAR-Fc delivery prevents cardiac dysfunction in CVB3 myocarditis under prophylactic and therapeutic conditions.


Assuntos
Infecções por Coxsackievirus/prevenção & controle , Regulação Viral da Expressão Gênica , Miocardite/prevenção & controle , Receptores Virais/biossíntese , Receptores Virais/genética , Doença Aguda , Animais , Cardiomiopatias/genética , Cardiomiopatias/prevenção & controle , Cardiomiopatias/virologia , Infecções por Coxsackievirus/genética , Terapia Genética/métodos , Células HeLa , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Miocardite/genética , Miocardite/virologia , Receptores Virais/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA