Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Life Sci Space Res (Amst) ; 39: 67-75, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37945091

RESUMO

We report the results of the first six years of measurements of the energetic particle radiation environment on the International Space Station (ISS) with the Radiation Assessment Detector (ISS-RAD), spanning the period from February 2016 to February 2022. The first RAD was designed and built for MSL, the Mars Science Laboratory rover, also known as Curiosity; it has been operating on Mars since 2012 and is referred to here as MSL-RAD. ISS-RAD combines two sensor heads, one nearly identical to the single MSL-RAD sensor head, the other with greatly enhanced sensitivity to fast neutrons. These two sensor heads are referred to as the Charged Particle Detector (CPD) and Fast Neutron Detector (FND), respectively. Despite its name, the CPD is also capable of measuring high-energy neutrons and γ-rays, as is MSL-RAD. ISS-RAD was flown to the ISS in December 2015 and was deployed in February 2016, initially in the USLab module. RAD was used as a survey instrument from January 2017 through May 2020, when the instrument was positioned in the USLab and set to a zenith-pointing orientation. The energetic particle environment on the ISS is complex and varies on short time scales owing to the orbit, which has a 51.6∘ inclination with respect to the equator and has had an altitude in the 400-440 km range in this time period. The ISS moves continuously through the geomagnetic field, the strength of which varies with latitude, longitude, and altitude. The orbit passes through the South Atlantic Anomaly (SAA) several times a day, where magnetically trapped protons and electrons produce large but transient increases in observed fluxes and absorbed dose rates. The environment inside the ISS is affected by the solar cycle, altitude, and the local shielding, which varies between different ISS modules. We report results for charged particle absorbed dose and dose equivalent rates in various positions in the ISS. In an accompanying paper, we report similar results for neutron dose equivalent rates obtained with the ISS-RAD Fast Neutron Detector.


Assuntos
Radiação Cósmica , Monitoramento de Radiação , Proteção Radiológica , Monitoramento de Radiação/métodos , Nêutrons , Prótons
2.
Life Sci Space Res (Amst) ; 39: 76-85, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37945092

RESUMO

We report the results of the first six years of measurements of so-called fast neutrons on the International Space Station (ISS) with the Radiation Assessment Detector (ISS-RAD), spanning the period from February 2016 to February 2022. ISS-RAD combines two sensor heads, one nearly identical to the single sensor head in the Mars Science Laboratory RAD (MSL-RAD). The latter is described in a companion article to this one. The novel sensor is the FND, or fast neutron detector, designed to measure neutrons with energies in the range from 200 keV to about 8 MeV. ISS-RAD was deployed in February 2016 in the USLAB module, and then served as a survey instrument from March 2017 until May 2020. Data were acquired in Node3, the Japanese Pressurized Module, Columbus, and Node2. At the conclusion of the survey portion of RAD's planned 10-year campaign on ISS, the instrument was stationed in the USLAB; current plans call for it to remain there indefinitely. The radiation environment on the ISS consists of a complex mix of charged and neutral particles that varies on short time scales owing to the Station's orbit. Neutral particles, and neutrons in particular, are of concern from a radiation protection viewpoint, because they are both highly penetrating (since they do not lose energy via direct ionization) and, at some energies, have high biological effectiveness. Neutrons are copiously produced by GCRs and other incident energetic particles when they undergo nuclear interactions in shielding. As different ISS modules have varying amounts of shielding, they also have varying neutron environments. We report results for neutron fluences and dose equivalent rates in various positions in the ISS.


Assuntos
Radiação Cósmica , Monitoramento de Radiação , Voo Espacial , Astronave , Nêutrons Rápidos , Monitoramento de Radiação/métodos , Nêutrons , Doses de Radiação
3.
Life Sci Space Res (Amst) ; 39: 86-94, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37945093

RESUMO

The energetic particle radiation environment on the International Space Station (ISS) includes both charged and neutral particles. Here, we make use of the unique capabilities of the Radiation Assessment Detector (ISS-RAD) to measure both of these components simultaneously. The Charged Particle Detector (CPD) is, despite its name, capable of measuring neutrons in the energy range from about 4 MeV to a few hundred MeV. Combined with data from the Fast Neutron Detector (FND) in the 0.2 to 8 MeV range, we present the first broad-spectrum measurements of the neutron environments in various locations within the ISS since an early Bonner-Ball experiment that was conducted before the Station was fully constructed. The data presented here span the time period from February 2016 to February 2022. In addition to presenting broad-spectrum neutron fluence measurements, we show correlations of the measured neutron dose equivalent with charged-particle dose rates. The ratio of charged-particle dose to neutron dose equivalent is found to be relatively stable within the ISS.


Assuntos
Radiação Cósmica , Monitoramento de Radiação , Nêutrons Rápidos , Astronave , Doses de Radiação , Monitoramento de Radiação/métodos , Nêutrons
4.
Life Sci Space Res (Amst) ; 29: 53-62, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33888288

RESUMO

In April 2001, Mars Odyssey spacecraft with the High Energy Neutron Detector (HEND) onboard was launched to Mars. HEND/Odyssey was switched on measurement mode for most of transit to Mars to monitor variations of spacecraft background and solar activity. Although HEND/Odyssey was originally designed to measure Martian neutron albedo and to search for Martian subsurface water/water ice, its measurements during cruise phase to Mars are applicable to evaluate spacecraft ambient radiation background. The biological impact of the neutron component of this radiation background should be understood, as it must be taken into account in planning future human missions to Mars. We have modeled the spacecraft neutron spectral density and compared it with HEND measurements to estimate neutron dose equivalent rates during Odyssey cruise phase, which occurred during the maximum period of solar cycle 23. We find that the Odyssey ambient neutron environment during May - September 2001 yields 10.6 ± 2.0 µSv per day in the energy range from 0 to 15 MeV, and about 29 µSv per day when extrapolated to the 0-1000 MeV energy range during solar quiet time (intervals without Solar Particle Events, SPEs). We have also extrapolated HEND/Odyssey measurements to different periods of solar cycle and find that during solar minimum (maximum of GCR flux), the neutron dose equivalent rate during cruise to Mars could be as high as 52 µSv per day with the same shielding. These values are in good agreement with results reported for a similar measurement made with an instrument aboard the Mars Science Laboratory during its cruise to Mars in 2011-2012.


Assuntos
Radiação Cósmica , Marte , Monitoramento de Radiação , Meio Ambiente Extraterreno , Humanos , Nêutrons , Doses de Radiação , Atividade Solar , Astronave
5.
Life Sci Space Res (Amst) ; 22: 89-97, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31421853

RESUMO

We report the first long-term measurements of the radiation quality factor of energetic charged particles on the surface of Mars. The Radiation Assessment Detector (RAD) aboard the Mars Science Laboratory rover, also known as Curiosity, has been operating on Mars since 2012. RAD contains thin silicon detectors that record the ionization energy loss of energetic charged particles. The particles are dominantly galactic cosmic rays (GCRs) and the products of their interactions in the Martian atmosphere, with occasional contributions from solar energetic particles (SEPs). The quality factor on the surface of Mars is influenced by two factors: variations in the shielding provided by the atmosphere, and changes in the spectrum of the incident energetic particle flux due to the 11-year solar cycle. The two cannot be easily disentangled using the data alone, but insights can be gained from calculations and Monte Carlo simulations.


Assuntos
Marte , Monitoramento de Radiação/instrumentação , Meio Ambiente Extraterreno , Método de Monte Carlo , Monitoramento de Radiação/métodos
6.
Life Sci Space Res (Amst) ; 9: 12-18, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27345198

RESUMO

Highly ionizing atomic nuclei HZE in the GCR will be a significant source of radiation exposure for humans on extended missions outside low Earth orbit. Accelerators such as the LBNL Bevalac and the BNL AGS, designed decades ago for fundamental nuclear and particle physics research, subsequently found use as sources of GCR-like particles for ground-based physics and biology research relevant to space flight. The NASA Space Radiation Laboratory at BNL was constructed specifically for space radiation research. Here we review some of the space-related physics results obtained over the first 20 years of NASA-sponsored research at Brookhaven.


Assuntos
Radiação Cósmica , Física Médica , Laboratórios/normas , Aceleradores de Partículas/instrumentação , Voo Espacial , United States National Aeronautics and Space Administration , Pesquisa Biomédica , Humanos , Radiobiologia , Estados Unidos
7.
Adv Space Res ; 35(2): 223-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15934198

RESUMO

We have measured charged nuclear fragments produced by 1 GeV/nucleon 56Fe ions interacting with aluminium, polyethylene and lead. These materials are relevant for assessment of radiation risk for manned space flight. The data will be presented in a form suitable for comparison with models of nuclear fragmentation and transport, including linear energy transfer (LET) spectrum, fluence for iron and fragments, event-tack- and event-dose-averaged LET, total dose and iron contribution to dose.


Assuntos
Radiação Cósmica , Íons Pesados , Ferro , Transferência Linear de Energia , Alumínio , Chumbo , Modelos Teóricos , Polimetil Metacrilato , Doses de Radiação , Monitoramento de Radiação/instrumentação , Proteção Radiológica , Espalhamento de Radiação , Voo Espacial , Astronave , Síncrotrons
8.
Adv Space Res ; 35(2): 202-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15934195

RESUMO

A new version of the HZETRN code capable of validation with HZE ions in either the laboratory or the space environment is under development. The computational model consists of the lowest order asymptotic approximation followed by a Neumann series expansion with non-perturbative corrections. The physical description includes energy loss with straggling, nuclear attenuation, nuclear fragmentation with energy dispersion and downshift. Measurements to test the model were performed at the Alternating Gradient Synchrotron and the NASA Space Radiation Laboratory at Brookhaven National Laboratory with iron ions. Surviving beam particles and produced fragments were measured with solid-state detectors. Beam analysis software has been written to relate the computational results to the measured energy loss spectra of the incident ions for rapid validation of modeled target transmission functions.


Assuntos
Radiação Cósmica , Íons Pesados , Modelos Teóricos , Física Nuclear , Proteção Radiológica , Alumínio , Simulação por Computador , Resinas Epóxi , Estudos de Avaliação como Assunto , Grafite , Ferro , Transferência Linear de Energia , Reprodutibilidade dos Testes , Espalhamento de Radiação , Síncrotrons
9.
Radiat Prot Dosimetry ; 116(1-4 Pt 2): 123-4, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16604611

RESUMO

Radiation dosimetry for manned spaced missions depends on the ability to adequately describe the process of high-energy ion transport through many materials. Since the types of possible nuclear interactions are many and complex, transport models are used which depend upon a reliable source of experimental data. To expand the heavy ion database used in the models we have been measuring charge-changing cross sections and fragment production cross sections from heavy-ion interactions in various elementa targets. These include materials flown on space missions such as carbon and aluminium, as well as those important in radiation dosimetry such as hydrogen, nitrogen and water. Measuring heavy-ion fragmentation through these targets also gives us the ability to determine the effectiveness of new materials proposed for shielding such as graphite composites and polyethylene hybrids. Measurement without a target present gives an indication of the level of contamination of the primary beam, which is also important in radiobiology experiments.


Assuntos
Materiais de Construção/análise , Radiação Cósmica , Íons Pesados , Proteção Radiológica/métodos , Radiometria/métodos , Astronave , Transferência Linear de Energia , Teste de Materiais , Doses de Radiação , Proteção Radiológica/instrumentação , Espalhamento de Radiação
10.
Life Sci Space Res (Amst) ; 5: 6-12, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26177845

RESUMO

The Mars Science Laboratory spacecraft, containing the Curiosity rover, was launched to Mars on 26 November 2011. Although designed for measuring the radiation on the surface of Mars, the Radiation Assessment Detector (RAD) measured the radiation environment inside the spacecraft during most of the 253-day, 560-million-kilometer cruise to Mars. An important factor for determining the biological impact of the radiation environment inside the spacecraft is the specific contribution of neutrons with their high biological effectiveness. We apply an inversion method (based on a maximum-likelihood estimation) to calculate the neutron and gamma spectra from the RAD neutral particle measurements. The measured neutron spectrum (12-436 MeV) translates into a radiation dose rate of 3.8±1.2 µGy/day and a dose equivalent of 19±5 µSv/day. Extrapolating the measured spectrum (0.1-1000 MeV), we find that the total neutron-induced dose rate is 6±2 µGy/day and the dose equivalent rate is 30±10 µSv/day. For a 360 day round-trip from Earth to Mars with comparable shielding, this translates into a neutron induced dose equivalent of about 11±4 mSv.


Assuntos
Raios gama , Nêutrons , Doses de Radiação , Monitoramento de Radiação/métodos , Atividade Solar , Radiação Cósmica , Marte , Proteção Radiológica , Astronave
11.
Radiat Res ; 149(6): 560-9, 1998 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9611094

RESUMO

We report beam characterization and dosimetric measurements made using a 56Fe beam extracted from the Brookhaven National Laboratory Alternating Gradient Synchrotron (AGS) with a kinetic energy of 1087 MeV/nucleon. The measurements reveal that the depth-dose distribution of this beam differs significantly from that obtained with a 600 MeV/nucleon iron beam used in several earlier radiobiology experiments at the Lawrence Berkeley National Laboratory's BEVALAC. We present detailed measurements of beam parameters relevant for radiobiology, including track- and dose-averaged linear energy transfer (LET), fragment composition and LET spectra measured behind sample holders used in irradiations of biological samples. We also report measurements of fluence behind three depths (1.94, 4.68 and 9.35 g cm(-2)) of polyethylene targets with the 1087 MeV/nucleon beam, and behind 1.94 g cm(-2) of polyethylene with a 610 MeV/nucleon beam delivered by the AGS. These results are compared to earlier measurements with the 600 MeV/nucleon beam at the BEVALAC.


Assuntos
Ferro , Síncrotrons , Transferência Linear de Energia , Doses de Radiação
12.
Radiat Res ; 149(4): 387-95, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9525504

RESUMO

Tissue-equivalent proportional counters (TEPCs) have been used to measure energy deposition in simulated volumes of tissue ranging in diameter from 0.1 to 10 microm. There has been some concern that the wall used to define the volume of interest could influence energy deposition within the sensitive volume because it has a density significantly greater than that of the cavity gas. These effects become important for high-velocity heavy ions. Measurements of energy deposition were made for 1 GeV/nucleon iron particles in a TEPC simulating a 1-microm-diameter sphere of tissue. The TEPC was nested within a particle spectrometer that provided identification and flight path of individual particles. Energy deposition was studied as a function of pathlength through the TEPC. Approximately 30% of the energy transfer along trajectories through the center of the detector escapes the sensitive volume. The response of the TEPC, for trajectories through the detector, is always larger than calculations for energy loss in a homogeneous medium. This enhancement is greatest for trajectories near the cavity/wall interface. An integration of the response indicates that charged-particle equilibrium is essentially achieved for a wall thickness of 2.54 mm. However, estimates of the linear energy transfer for the incident particles are influenced by these wall effects.


Assuntos
Radiometria/instrumentação , Gases , Radioisótopos de Ferro , Transferência Linear de Energia , Radioquímica , Silício , Síncrotrons
13.
Radiat Res ; 159(3): 381-90, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12600241

RESUMO

Accelerator-based measurements and model calculations have been used to study the heavy-ion radiation transport properties of materials in use on the International Space Station (ISS). Samples of the ISS aluminum outer hull were augmented with various configurations of internal wall material and polyethylene. The materials were bombarded with high-energy iron ions characteristic of a significant part of the galactic cosmic-ray (GCR) heavy-ion spectrum. Transmitted primary ions and charged fragments produced in nuclear collisions in the materials were measured near the beam axis, and a model was used to extrapolate from the data to lower beam energies and to a lighter ion. For the materials and ions studied, at incident particle energies from 1037 MeV/nucleon down to at least 600 MeV/nucleon, nuclear fragmentation reduces the average dose and dose equivalent per incident ion. At energies below 400 MeV/nucleon, the calculation predicts that as material is added, increased ionization energy loss produces increases in some dosimetric quantities. These limited results suggest that the addition of modest amounts of polyethylene or similar material to the interior of the ISS will reduce the dose to ISS crews from space radiation; however, the radiation transport properties of ISS materials should be evaluated with a realistic space radiation field.


Assuntos
Radiação Cósmica , Íons Pesados , Proteção Radiológica/estatística & dados numéricos , Astronave/instrumentação , Alumínio , Grafite , Transferência Linear de Energia , Modelos Teóricos , Aceleradores de Partículas , Polietileno , Proteção Radiológica/instrumentação
14.
Radiat Res ; 145(6): 655-65, 1996 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8643824

RESUMO

The fragmentation of 510 MeV/nucleon iron ions in several thicknesses of polyethylene has been measured. Non-interacting primary beam particles and fragments have been identified and their LETs calculated by measuring ionization energy loss in a stack of silicon detectors. Fluences, normalized to the incident beam intensity and corrected for detector effects, are presented for each fragment charge and target. Histograms of fluence as a function of LET are also presented. Some implications of these data for measurements of the biological effects of heavy ions are discussed.


Assuntos
Ferro/química , Transferência Linear de Energia , Algoritmos , Animais , Humanos , Modelos Teóricos , Aceleradores de Partículas , Polietilenos , Efeitos da Radiação , Silício
15.
Radiat Res ; 162(6): 687-92, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15548122

RESUMO

Experiments have been performed to measure the response of a spherical tissue-equivalent proportional counter (TEPC) and a silicon-based LET spectrometer (RRMD-III) to protons with energies ranging from 50-200 MeV. This represents a large portion of the energy distribution for trapped protons encountered by astronauts in low-Earth orbit. The beam energies were obtained using plastic polycarbonate degraders with a monoenergetic beam that was extracted from a proton synchrotron. The LET spectrometer provided excellent agreement with the expected LET distribution emerging from the energy degraders. The TEPC cannot measure the LET distribution directly. However, the frequency mean value of lineal energy, y(-)(f), provided a good approximation to LET. This is in contrast to previous results for high-energy heavy ions where y(-)(f) underestimated LET, whereas the dose-averaged lineal energy, y(-)(D), provided a good approximation to LET.


Assuntos
Transferência Linear de Energia , Prótons , Radiometria , Silício
16.
Radiat Res ; 157(3): 350-60, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11839098

RESUMO

The radiation environment on board the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. Iron-56 particles are considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPCs) are used as active dosimeters on manned space flights. These TEPCs are further used to determine the average quality factor for each space mission. A TEPC simulating a 1-microm-diameter sphere of tissue was exposed as part of a particle spectrometer to (56)Fe particles at energies from 200-1000 MeV/nucleon. The response of TEPCs in terms of mean lineal energy, y(F), and dose mean lineal energy, y(D), as well as the energy deposited at different impact parameters through the detector was determined for six different incident energies of (56)Fe particles in this energy range. Calculations determined that charged-particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using a radial dose distribution model, and the results were compared to experimental data.


Assuntos
Radiação Cósmica , Ferro
17.
Radiat Res ; 145(6): 666-72, 1996 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8643825

RESUMO

The results of a Monte Carlo model for calculating fragment fluences and LET spectra are compared to data taken with 600 MeV/nucleon iron ions incident on an accelerator beamline configured for irradiation of biological samples, with no target and with 2, 5 and 8 cm of polyethylene. The model uses a multi-generation nuclear fragmentation code, coupled with a formulation of ionization energy loss based on the Bethe-Bloch equation. In the region where the data are reliable and the experimental acceptance is well understood, many of the features of the experimental spectra are well replicated by the model. To obtain good agreement with the experimental data, the model must allow for at least two generations of fragment production in the target.


Assuntos
Ferro/química , Algoritmos , Transferência Linear de Energia , Manganês , Matemática , Modelos Teóricos , Método de Monte Carlo , Polietilenos
18.
Br J Clin Psychol ; 23 ( Pt 1): 27-35, 1984 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-6697026

RESUMO

A controlled study of a group of patients with severe migraine revealed that they gave a consistently poorer performance on a series of memory and information-processing tests (12 subtests in all). Migraine sufferers were also found to differ from controls significantly on the anxiety, obsessionality and somatic scales of the Middlesex Hospital Questionnaire, although it was considered unlikely that the differences in cognitive performance could be explained by these results.


Assuntos
Transtornos Cognitivos/psicologia , Transtornos de Enxaqueca/psicologia , Transtornos Neurocognitivos/psicologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes Psicológicos , Psicometria
19.
Adv Space Res ; 33(12): 2211-4, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15791733

RESUMO

The charged particle spectrum for nuclei from protons to neon, (charge Z=10) was observed during the cruise phase and orbit around Mars by the MARIE charged particle spectrometer on the Odyssey spacecraft. The cruise data were taken between April 23, 2001 and mid-August 2001. The Mars orbit data were taken March 5, 2002 through May 2002 and are scheduled to continue until August 2004. Charge peaks are clearly separated for charges up to Z=10. Especially prominent are the carbon and oxygen peaks, with boron and nitrogen also clearly visible. Although heavy ions are much less abundant than protons in the cosmic ray environment, it is important to determine their abundances because their ionization energy losses (proportional to Z2) are far more dangerous to humans and to instruments. Thus the higher charged nuclei make a significant contribution to dose and dose equivalent received in space. Results of the charged particle spectrum measurements will be reported.


Assuntos
Radiação Cósmica , Marte , Monitoramento de Radiação/instrumentação , Voo Espacial/instrumentação , Calibragem , Íons Pesados , Hélio , Neônio , Prótons , Doses de Radiação , Astronave/instrumentação
20.
Adv Space Res ; 33(12): 2219-21, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15791735

RESUMO

The 2001 Mars Odyssey spacecraft was launched towards Mars on April 7, 2001. Onboard the spacecraft is the Martian radiation environment experiment (MARIE), which is designed to measure the background radiation environment due to galactic cosmic rays (GCR) and solar protons in the 20-500 MeV/n energy range. We present an approach for developing a space radiation-shielding model of the spacecraft that includes the MARIE instrument in the current mapping phase orientation. A discussion is presented describing the development and methodology used to construct the shielding model. For a given GCR model environment, using the current MARIE shielding model and the high-energy particle transport codes, dose rate values are compared with MARIE measurements during the early mapping phase in Mars orbit. The results show good agreement between the model calculations and the MARIE measurements as presented for the March 2002 dataset.


Assuntos
Radiação Cósmica , Marte , Modelos Teóricos , Proteção Radiológica , Voo Espacial/instrumentação , Simulação por Computador , Doses de Radiação , Monitoramento de Radiação/instrumentação , Atividade Solar , Astronave/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA