Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Opt Express ; 30(12): 22051-22065, 2022 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-36224912

RESUMO

The orientation of a single molecule provides valuable information on fundamental biological processes. We report a technique for the simultaneous estimation of single-molecule 2D position and 2D orientation with ultra-high localization precision (∼2-nm precision with ∼500 photons under a typical 100-nm diameter of excitation beam pattern), which is also compatible with tracking in living cells. In the proposed method, the theoretical precision limits are calculated, and the localization and orientation performance along with potential applications are explored using numerical simulations. Compared to other camera-based orientation measurement methods, it is confirmed that the proposed method can obtain reasonable estimates even under very weak signals (∼15 photons). Moreover, the maximum likelihood estimator (MLE) is found to converge to the theoretical limit when the total number of photons is less than 100.


Assuntos
Nanotecnologia , Fótons
2.
Opt Express ; 30(26): 46849-46860, 2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36558626

RESUMO

A novel super-resolution imaging technique based on the minimum photon flux (MINFLUX), can achieve nanometer-scale localization precision and sub-5-nm imaging. However, aberrations can affect the localization performance and degrade the quality of reconstructed images. In this study, we analyze the effects of different low-order aberrations on the MINFLUX system through both theoretical limits and Monte Carlo methods. We report that 1) defocus and spherical aberration have little effect on 2D localization performance, whereas astigmatism and coma have significant negative effects; 2) system aberrations that can be measured in advance cause changes primarily in the magnitude and angular uniformity of localization precision, whereas sample-induced aberrations that cannot be a priori introduce large biases and reduce localization accuracy.

3.
Ann Palliat Med ; 10(2): 2062-2071, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33615812

RESUMO

BACKGROUND: To retrospectively analyze the pulmonary computed tomography (CT) characteristics and dynamic changes in the lungs of cured coronavirus disease 2019 (COVID-19) patients at discharge and reexamination. METHODS: A total of 155 cured COVID-19 patients admitted to designated hospitals in Yunnan Province, China, from February 1, 2020, to March 20, 2020, were included. All patients underwent pulmonary CT at discharge and at 2 weeks after discharge (during reexamination at hospital). A retrospective analysis was performed using these two pulmonary CT scans of the cured patients to observe changes in the number, distribution, morphology, and density of lesions. RESULTS: At discharge, the lung CT images of 15 cured patients showed no obvious lesions, while those of the remaining 140 patients showed different degrees of residual lesions. Patients with moderate disease mostly had multiple pulmonary lesions, mainly in the lower lobes of both lungs. At reexamination, the lung lesions in the patients with moderate disease had significantly improved (P<0.05), and the lung lesions in the patients with severe disease had partially improved, especially in patients with multi-lobe involvement (χ 2 =3.956, P<0.05). At reexamination, the lung lesions of patients with severe disease did not show significant changes (P>0.05). CONCLUSIONS: The pulmonary CT manifestations of cured COVID-19 patients had certain characteristics and variation patterns, providing a reference for the clinical evaluation of treatment efficacy and prognosis of patients.


Assuntos
COVID-19/diagnóstico por imagem , Sobreviventes , Tomografia Computadorizada por Raios X , China , Humanos , Pulmão/diagnóstico por imagem , Alta do Paciente , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA