Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Inorg Chem ; 62(44): 18248-18256, 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37870805

RESUMO

Based on the hard-soft acid base (HSAB) theory, three robust isoreticular metal-organic frameworks (MOFs) with nia topology were successfully synthesized by solvothermal reaction {[In3O(BHB)(H2O)3]NO3·3DMA (JLU-MOF110(In)), [Fe3O(BHB)(H2O)3]NO3 (JLU-MOF110(Fe)), and [Fe2NiO(BHB)(H2O)3] (JLU-MOF110(FeNi)) (DMA = N,N-dimethylacetamide, H6BHB = 4,4″-benzene-1,3,5-triyl-hexabenzoic acid)}. Both JLU-MOF110(In) and JLU-MOF110(Fe) are cationic frameworks, and their BET surface areas are 301 and 446 m2/g, respectively. By modification of the components of metal clusters, JLU-MOF110(FeNi) features a neutral framework, and the BET surface area is increased up to 808 m2/g. All three MOF materials exhibit high chemical and thermal stability. JLU-MOF110(In) remains stable for 24 h at pH values ranging from 1 to 11, while JLU-MOF110(Fe) and JLU-MOF110(FeNi) persist to be stable for 24 h at pH from 1 to 12. JLU-MOF110(In) exhibits thermal stability up to 350 °C, whereas JLU-MOF110(Fe) and JLU-MOF(FeNi) can be stable up to 300 °C. Thanks to the microporous cage-based structure and abundant open metal sites, JLU-MOF110(In), JLU-MOF110(Fe), and JLU-MOF110(FeNi) have excellent CO2 capture capacity (28.0, 51.5, and 99.6 cm3/g, respectively, under 298 K and 1 bar). Interestingly, the ideal adsorption solution theory results show that all three MOFs exhibit high separation selectivity toward CO2 over N2 (35.2, 43.2, and 43.2 for CO2/N2 = 0.15/0.85) and CO2 over CH4 (14.4, 11.5, and 10.1 for CO2/CH4 = 0.5/0.5) at 298 K and 1 bar. Thus, all three MOFs are potential candidates for CO2 capture and separation. Among them, JLU-MOF110(FeNi) displays the best separation potential, as revealed by dynamic column breakthrough experiments.

2.
Knee Surg Sports Traumatol Arthrosc ; 31(11): 5255-5269, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37775643

RESUMO

PURPOSE: To compare the clinical outcomes and retear rates after rotator cuff repair (RCR) between delaminated and non-delaminated tears. METHODS: This systematic review was conducted according to the preferred reporting items for systematic reviews and meta-analyses guidelines using the PubMed, Cochrane Library, the Web of Science and Embase databases. Only articles on arthroscopic RCR with clinical outcome scores and data on the number of rotator cuff retears and complete healing were included. This study's relevant data were extracted and statistically analyzed. The methodological index for nonrandomized studies was used to assess the risk of bias in the included studies. After conducting a heterogeneity test and sensitivity analysis to determine whether the samples were heterogeneous, the study also detected publication bias. A sub-group test was used to evaluate the influences of the imaging follow-up period on retear rates. RESULTS: Ten eligible articles were identified with 2,061 patients (925 in the delaminated group and 1,136 in the non-delaminated group). The meta-analysis demonstrated that delamination was significantly associated with higher retear rates (P = 0.026; odds ratio = 1.873, 95% confidence interval 1.079-3.252; I2 = 51.6%) with an imaging follow-up period of > 1 year and lower rates of complete healing (P = 0.036; odds ratio = 0.659, 95% confidence interval 0.446-0.973; I2 = 9.0%) in patients after rotator cuff repair. However, no significant differences were observed between the two groups based on American Shoulder and Elbow Surgeons score, Constant score, visual analog scale score, external rotation, internal rotation, or forward elevation. CONCLUSIONS: This meta-analysis found that delamination was significantly associated with higher retear rates with imaging follow-up period of > 1 year, and lower rates of complete healing. In addition, the preoperative and postoperative clinical scores and shoulder joint range of motion were similar between patients with delaminated and non-delaminated tears. LEVEL OF EVIDENCE: Level IV.

3.
J Shoulder Elbow Surg ; 32(11): 2400-2411, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37419440

RESUMO

BACKGROUND: Obesity influences the outcomes of orthopedic surgeries such as total knee arthroplasty and spinal surgery. However, the effect of obesity on the outcomes of rotator cuff repair is unknown. This systematic review and meta-analysis aimed to examine the effect of obesity on rotator cuff repair outcomes. METHODS: PubMed, EMBASE, Web of Science, and Cochrane Library databases were searched to identify relevant studies published from their inception till July 2022. Two reviewers independently screened titles and abstracts using the specified criteria. Articles were included if they indicated the effect of obesity on rotator cuff repair and the related outcomes after surgery. Review Manager 5.4.1 software was used to perform statistical analysis. RESULTS: Thirteen articles involving 85,497 patients were included. Obese patients had higher retear rates than nonobese patients (odds ratio [OR] 2.58, 95% confidence interval [CI] 1.23-5.41, P = .01), lower American Shoulder and Elbow Surgeons scores (mean difference [MD]: -3.59, 95% CI: -5.45 to [-1.74]; P = .0001), higher visual analog scale for pain (mean difference: 0.73, 95% CI: 0.29-1.17; P = .001), higher reoperation rates (OR 1.31, 95% CI 1.21-1.42, P < .00001), and higher rates of complications (OR 1.57, 95% CI 1.31-1.87, P = .000). Obesity did not affect the duration of surgery (MD: 6.03, 95% CI: -7.63 to 19.69; P = .39) or external rotation of the shoulder (MD: -1.79, 95% CI: -5.30 to 1.72; P = .32). CONCLUSION: Obesity is a significant risk factor for retear and reoperation after rotator cuff repair. Furthermore, obesity increases the risk of postoperative complications and leads to lower postoperative American Shoulder and Elbow Surgeons scores and higher shoulder visual analog scale for pain.

4.
Arch Orthop Trauma Surg ; 143(5): 2653-2663, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36194254

RESUMO

PURPOSE: This systematic review and meta-analysis aimed to evaluate the correlation between increased critical shoulder angle (CSA) and higher retear rates and functional outcomes after arthroscopic rotator cuff repair (ARCR). METHODS: PubMed, Embase, Web of Science, and Cochrane Library databases published before January 2022 were comprehensively searched. Two reviewers independently reviewed the titles and abstracts using the specified criteria. Studies were included if the authors clearly described the correlation between the CSA and rotator cuff repair. Data on patient characteristics, mean CSA, retear rate, and the functional score was pooled from the selected articles. A meta-analysis was performed using Review Manager (RevMan) 5.4.1 software, 2020 (Cochrane Collaboration, Copenhagen, Denmark). RESULTS: Eleven articles involving 1449 patients from 7 countries were included. The ages of the patients ranged from 45 to 75 years. The follow-up period ranged from 6 to 96 months. The mean CSA was greater in the retear group than in the non-retear group after ARCR (mean difference 2.73°; 95% confidence interval [CI] 0.69-4.77) (p = 0.009). Three studies evaluated the association between increased CSA and the postoperative retear rate. All three studies showed a higher postoperative retear rate in patients with an increased CSA (odds ratio 5.35; 95% CI 2.02-14.15; p = 0.0007). No association was found between CSA and Constant-Murley (Constant), the University of California at Los Angeles (UCLA), or Visual Analog Scale (VAS) scores during the follow-up period of 24-96 months (p > 0.05). CONCLUSIONS: This systematic review and meta-analysis showed that CSA correlates highly with rotator cuff retear after ARCR. In addition, the postoperative retear rate of the rotator cuff increased with increased CSA. CSA appeared to not affect worse functional outcomes in patients after ARCR.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Pessoa de Meia-Idade , Idoso , Ombro/cirurgia , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Resultado do Tratamento , Articulação do Ombro/cirurgia , Artroscopia , Imageamento por Ressonância Magnética
5.
Inorg Chem ; 61(8): 3708-3715, 2022 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-35167753

RESUMO

Here, a Y(III)-based metal-organic framework, JLU-MOF112 {[Y3(µ3-O)2(µ3-OH)(H2O)2(BTCTBA)2]·2[(CH3)2NH2]·5DMF·C6H5Cl·4H2O}, has been successfully synthesized under solvothermal conditions. JLU-MOF112 was constructed with amide-functionalized tricarboxylate ligands and Y(III)-based infinite chains, where the Y3 repeating units are arranged in a trans order. The overall framework could be viewed as a novel (3,5)-connected net with two types of channels along the [100] and [010] directions. JLU-MOF112 possesses a large BET surface area (1553 m2 g-1), a permanent pore volume (0.67 cm3 g-1), and outstanding thermal and chemical stability, which give JLU-MOF112 potential for the purification of natural gas, especially the equimolar separation of C3H8/CH4 with a high selectivity of 176. In addition, benefiting from the amide functional groups as Brønsted basic sites and the exposure of open metal sites as Lewis acid sites after activation, JLU-MOF112 can serve as a high-efficiency heterogeneous catalyst for Knoevenagel condensation by the reactions of malononitrile with benzaldehyde (yield of 98%, turnover number of 392, and turnover frequency of 3.27 min-1) and diverse aldehyde compounds. A rational mechanism was put forward that the Knoevenagel condensation was catalyzed by the synergistic effect of the Lewis acid sites and Brønsted basic sites, engendering the polarization of the carbonyl groups and the deprotonation of the methylene groups for nucleophilic attack.

6.
J Colloid Interface Sci ; 658: 699-713, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38141392

RESUMO

Due to the poor thermal stability of conventional separators, lithium-ion batteries require a suitable separator to maintain system safety for long-term cycling performance. It must have high porosity, superior electrolyte uptake ability, and good ion-conducting properties even at high temperatures. In this work, we demonstrate a novel composite membrane based on sandwiching of zeolitic imidazole frameworks-67 decorated cellulose acetate nanofibers (ZIF-67@CA) with electrospun poly(vinyl alcohol)/melamine (denoted as PVAM) nonwoven membranes. The as-prepared sandwich-type membranes are called PVAM/x%ZIF-67@CA/PVAM. The middle layer of composite membranes is primarily filled with different weight percentages of ZIF-67 nanoparticles (x = 5, 15, and 25 wt%), which both reduces the non-uniform porous structure of CA and increases its thermal stability. Therefore, our sandwich-type PVAM/x%ZIF-67@CA/PVAM membrane exhibits a higher thermal shrinkage effect at 200 °C than the commercial polyethylene (PE) separator. Due to its high electrolyte uptake (646.8%) and porosity (85.2%), PVAM/15%ZIF-67@CA/PVAM membrane achieved high ionic conductivity of 1.46 × 10-3 S cm-1 at 70 °C, as compared to the commercial PE separator (ca. 6.01 × 10-4 S cm-1 at 70 °C). Besides, the cell with PVAM/15%ZIF-67@CA/PVAM membrane shows an excellent discharge capacity of about 167.5 mAh g-1after 100 cycles at a 1C rate with a capacity retention of 90.3%. The ZIF-67 fillers in our sandwich-type composite membrane strongly attract anions (PF6-) through Lewis' acid-base interaction, allowing uniform Li+ ion transport and suppressing Li dendrites. As a result, we found that the PVAM/15%ZIF-67@CA/PVAM composite nonwoven membrane is applicable to high-power, high-safety lithium-ion battery systems that can be used in electric vehicles (EVs).

7.
Indian J Orthop ; 57(2): 227-237, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36777118

RESUMO

Purpose: Fatty infiltration (FI) of the rotator cuff muscles occurs after rotator cuff tears (RCTs), which may affect the outcome of the repair procedure. This study aimed to determine the relationship between preoperative FI and the rate of re-tear and functional outcomes after rotator cuff repair. Methods: Computerized databases, including PubMed, EMBASE, Web of Science, and Cochrane Library database were searched for studies published from the inception date to January 2022. Two reviewers independently screened the titles and abstracts using prespecified criteria. Articles were included if they clearly stated the effect of varying degrees of FI on the outcome after shoulder cuff repair. Comparison was performed by different degrees of FI analysis: no FI is grade 0-1, FI is grade 2 and above. Statistical analysis was performed using Review Manager 5.4.1 software. Results: A total of 16 articles involving 1383 patients from 8 countries were included. The follow-up period ranged from 8 to 121 months. In terms of re-tear rate: patients with preoperative FI had significantly higher rates of re-tear compared with patients without FI (OR 4.60, 95% CI 2.22-9.54, p < 0.0001), supraspinatus FI VS no FI (OR 2.06, 95% CI 1.00-4.24, p = 0.05), infraspinatus FI VS no FI (OR 2.42, 95% CI 1.19-4.91, p = 0.01). In terms of functional scoring: patients without FI had higher postoperative Constant-Murley (Constant) scores than those with FI (MD - 5.06, 95% CI - 9.40 to - 0.72, p = 0.02), there was no clear evidence that preoperative FI was related to postoperative American Society of shoulder and elbow physicians scores and the University of California at Los Angeles scores and range of motion. Conclusion: FI after RCTs significantly increases the risk of postoperative re-tear and leads to worse functional scores, especially FI of the infraspinatus muscle. However, FI does not seem to reduce postoperative range of motion. Supplementary Information: The online version contains supplementary material available at 10.1007/s43465-022-00807-0.

8.
Zhongguo Gu Shang ; 36(2): 193-8, 2023 Feb 25.
Artigo em Zh | MEDLINE | ID: mdl-36825425

RESUMO

Superior labrum anterior posterior (SLAP) injury is a major challenge for orthopedic surgeons, due to the poor healing ability of the injured labrum. Although arthroscopic surgery is the gold standard for the treatment of SLAP injury, there are still disputes about the adaptation of different surgical techniques, the choice of anchors during operation, knotted or knotless anchors, and fixation methods. The authors believe that arthroscopic repair of SLAP lesions is effective for young patients with intact glenoid labrum(<35 years old) or with extensive activity, where single and knotless anchor is preferred. For the older patients(≥35 years old) with degeneration and wear of glenoid labrum, biceps tenodesis is more preferable, and interference screw fixation technique is recommended. As for patients with failed SLAP repair, biceps tenodesis can achieve a high success rate as a revision surgery. By review of the relevant literature in recent years, this paper summarizes the adaptation of different surgical methods of arthroscopic treatment of SLAP injury, intraoperative anchoring techniques, fixation methods and other improved surgical techniques.


Assuntos
Lesões do Ombro , Articulação do Ombro , Traumatismos dos Tendões , Tenodese , Humanos , Adulto , Articulação do Ombro/cirurgia , Artroscopia/métodos , Traumatismos dos Tendões/cirurgia , Lesões do Ombro/cirurgia , Tenodese/métodos
9.
J Orthop Surg Res ; 17(1): 23, 2022 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-35033135

RESUMO

PURPOSE: The treatment of anterior shoulder instability is a focus in the field of sports medicine. While much research has been conducted, few bibliometric studies have been performed in this field. This study analyzed the main characteristics and identified emerging research trends and hotspots related to the treatment of anterior shoulder instability over the past four decades. METHODS: We searched for (anterior shoulder instability OR anterior shoulder dislocation) AND (treatment OR reconstruction) in ARTICLE (Mesh) in the Web of Science database from 1980 to 2020. We analyzed the keywords, author, institution, country, number of citations, average number of citations, publication year, and partnership of the identified articles. Information about annual publications was analyzed using Microsoft Excel 2019; the remaining data were analyzed using VOSviewer version 1.6.11 (Leiden University, Leiden, Netherlands) and CiteSpace version 5.7.R2 (Drexel University, Philadelphia, PA, USA). RESULTS: A total of 1964 articles were published between 1980 and 2020. The American Journal of Sports Medicine, the United States, the United States Department of Defense, and Arcieio were journals, countries, institutions, and authors with the highest numbers of publications. The topic hotspots were instability, shoulder, and dislocation, while the research frontiers were arthroscopic, Bankart repair, Latarjet procedure, risk factors, recurrence, and complications. CONCLUSION: The treatment of anterior shoulder instability has shown an increasing number of publications each year and achieved great progress. The United States made the most outstanding contributions to this important field. Arthroscopic, Bankart repair, and Latarjet procedures were research hotspots and risk factors, recurrence, and complications were likely to research frontiers.


Assuntos
Artroscopia/métodos , Instabilidade Articular , Luxação do Ombro/cirurgia , Articulação do Ombro/cirurgia , Bibliometria , Humanos , Instabilidade Articular/cirurgia , Recidiva , Ombro
10.
J Orthop Surg Res ; 17(1): 28, 2022 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-35033137

RESUMO

BACKGROUND: Rotator cuff tears are one of the most common shoulder injuries in the older population. This study aimed to determine whether acromioplasty reliably decreases the critical shoulder angle (CSA) and describe any associated complications. METHODS: A systematic literature review was performed according to PRISMA guidelines using PubMed, EMBASE, Web of Science, and Cochrane Library Database. Two reviewers independently screened the titles and abstracts using prespecified criteria. Studies where the acromioplasty was performed as a surgical procedure were included. Patient characteristics and degree of CSA reduction were collected from each individual study. All statistical analyses were performed using Review Manager (RevMan) 5.4.1 software. A random-effects model was used for meta-analysis. RESULTS: A total of 9 studies involving 1236 patients were included in the meta-analysis. The age of patients ranged from 23 to 82 years. The follow-up period ranged from 12 to 30 months. Of the 9 studies, 8 (88.9%) were retrospective, 1 (11.1%) was prospective, 5 were comparative, and 4 were case series. The mean CSA was significantly reduced from 36.1° ± 4.6° to 33.7° ± 4.2 (p < 0.05). The meta-analysis showed an overall best estimate of the mean difference in pre- and postoperative CSA equal to 2.63° (95% confidence interval: 2.15, 3.11] (p < 0.00001). CONCLUSIONS: Acromioplasty can significantly reduce CSA, notably in cases of high preoperative CSA. In addition, the effect of lateral acromioplasty on the CSA was more significant compared to anterolateral acromioplasty. Acromioplasty was not associated with complications during the short-term follow-up.


Assuntos
Acrômio/cirurgia , Artroscopia , Lesões do Manguito Rotador , Articulação do Ombro , Acrômio/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Ombro , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Adulto Jovem
11.
Zhongguo Gu Shang ; 35(6): 506-11, 2022 Jun 25.
Artigo em Zh | MEDLINE | ID: mdl-35730218

RESUMO

OBJECTIVE: To compare difference in clnical efficacy between arthroscopic double posterior internal approach and incisional surgery for acute simple posterior cruciate ligament tibial avulsion fractures. METHODS: Totally 52 patients with acute simple posterior cruciate ligament tibial avulsion fractures treated from June 2016 to June 2020 were retrospectively analyzed and divided into two groups according to different surgical protocols, 27 patients in arthroscopic group were treated with arthroscopic double posterior internal approach, including 16 males and 11 females, aged from 19 to 52 years old, with an average age of (34.9±9.2) years old;25 patients in open reduction group were treated with posterior medial knee incision, including 14 males and 11 females, aged from 18 to 54 years old , with an average age of(33.7±8.4) years old. Operation time, incision length, intraoperative bleeding, hospitalization days, hospitalization cost, fracture healing, complications, postoperative Lysholm score and IKDC score at 12 months were observed and compared between two groups. RESULTS: All patients in both groups were completed opertaion successfully without vascular or nerve injury, and 52 patients were followed up from 6 to 24 months with an average of (15.0±1.7) months. Operation time and hospitalization cost in arthroscopic group were significantly greater than those in open reduction group(P<0.05);intraoperative bleeding, incision length, and hospitalization days in arthroscopic group were less than those in open reduction group(P<0.05);preoperative Lysholm score in arthroscopic group and open reduction group were 49.1±2.3 and 48.9±1.1 respectively, and improved to 95.9±1.7 and 86.4±1.2 at 12 months after operation respectively(P<0.05);preoperative IKDC scores in arthroscopic group and open reduction group were 47.6±4.1 and 48.1±3.9 respectively, and improved to 96.9±1.5 and 87.1±1.4 at 12 months after operation(P<0.05). CONCLUSION: Arthroscopic double posterior internal approach for acute simple posterior cruciate ligament tibial stop avulsion fracture has satisfactory early results and better efficacy than traditional open surgery, which has advantages of less trauma, faster recovery and easier operation.


Assuntos
Fratura Avulsão , Ligamento Cruzado Posterior , Fraturas da Tíbia , Adolescente , Adulto , Artroscopia/métodos , Feminino , Fixação Interna de Fraturas/métodos , Fratura Avulsão/cirurgia , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Ligamento Cruzado Posterior/lesões , Ligamento Cruzado Posterior/cirurgia , Estudos Retrospectivos , Técnicas de Sutura , Fraturas da Tíbia/cirurgia , Resultado do Tratamento , Adulto Jovem
12.
Zhongguo Gu Shang ; 35(3): 233-7, 2022 Mar 25.
Artigo em Zh | MEDLINE | ID: mdl-35322612

RESUMO

OBJECTIVE: To investigate the early efficacy of arthroscopic autologous osteochondral grafting in the treatment of recurrent anterior shoulder dislocation. METHODS: From January 2019 to January 2021, 17 patients with recurrent anterior dislocation of shoulder who underwent arthroscopic autologous osteochondral grafting were selected, including 12 males and 5 females, ranging in age from 17 to 55 years old, with a mean of (32.88±12.33) years old. Rowes rating system for Bankart repair(Rowe), Oxford Shoulder Instability Score (OSIS) and Simple Shoulder Test (SST) were compared before operation, 6 months after operation and at the latest follow-up. OSIS and SST used to evaluate shoulder function were recorded before surgery and at the latest follow-up. The shoulder mobility and intraoperative and postoperative complications were also recorded. RESULTS: All 17 patients were followed up, and the duration ranged from 7 to 25 months, with a mean of (18.4±5.4) months. During the follow-up period, there was no re-dislocation, no vascular or nerve injury. Rowe score increased from 26.2±6.0 before operation to 74.4±4.0 and 82.4±3.1 after 6 months and the latest follow-up. There was significant difference in Rowe score between different time points after operation and before operation (P<0.05). The OSIS increased from 37.0±3.6 before operation to 47.4±2.6 and 52.7±2.6 after 6 months and the latest follow-up. There was significant difference in OSIS between different time points after operation and before operation (P<0.05). The SST score increased from 6.8±0.7 before operation to 9.8±0.8, 11.6±2.6 after 6 months and the latest follow-up. There was significant difference in SST score between different time points after operation and before operation (P<0.05). At the latest follow-up, the lateral external rotation and abduction external rotation activities of the patient were significantly improved compared with those before operation. CONCLUSION: This study provides preliminary evidence that arthroscopic autologous osteochondral grafting can achieve satisfactory early clinical outcomes and stability in patients with recurrent anterior shoulder dislocation with glenoid fracture and defect less than <20%, which is a reliable and effective procedure.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Adolescente , Adulto , Artroscopia/métodos , Feminino , Humanos , Instabilidade Articular/cirurgia , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Luxação do Ombro/cirurgia , Articulação do Ombro/cirurgia , Adulto Jovem
13.
Zhongguo Gu Shang ; 35(10): 996-9, 2022 Oct 25.
Artigo em Zh | MEDLINE | ID: mdl-36280420

RESUMO

OBJECTIVE: To investigate the method and clinical effects of the treatment of recurrent shoulder dislocation with severe glenoid injury by arthroscopic subscapularis augmentation. METHODS: From March 2019 to August 2020, 16 patients with recurrent dislocation of shoulder with severe glenoid injury underwent arthroscopic subscapularis augmentation, including 10 males and 6 females, aged from 18 to 50 years old with an average of (29.06±10.54) years old, 4 cases of left shoulder and 12 cases of right shoulder.Visual analogue scale (VAS), American Shoulder and Elbow Surgeons (ASES) score and Rowe score were used to evaluate shoulder function and stability before and after operation. RESULTS: All the 16 patients were followed up from 12 to 29 months, with an average of (18.75±7.26) months. VAS score decreased from 5.25±1.13 before operation to 1.37±0.65 at the final follow-up;ASES score increased from 59.44±9.93 before surgery to 90.88±4.00 at the final follow-up; Rowe score of shoulder increased from 51.56±8.89 before surgery to 92.19±7.06 at the final follow-up, and the differences were statistically significant (P<0.05). No dislocation was observed during follow-up. No clinical complications such as incision infection, vascular and nerve injury occurred in all patients after operation. CONCLUSION: Arthroscopic subscapularis augmentation in the treatment of recurrent dislocation of shoulder with severe glenoid injury is satisfactory. It is an effective treatment method of recurrent dislocation of shoulder joint with severe glenoid injury, and external rotation function in patients with almost unaffected.


Assuntos
Luxações Articulares , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Masculino , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Manguito Rotador , Ombro/cirurgia , Luxação do Ombro/cirurgia , Instabilidade Articular/cirurgia , Artroscopia/métodos , Articulação do Ombro/cirurgia , Resultado do Tratamento , Recidiva , Estudos Retrospectivos
14.
Life Sci Space Res (Amst) ; 25: 107-118, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32414484

RESUMO

Health risks from galactic cosmic rays (GCR) in space travel above low earth orbit remain a concern. For many years accelerator experiments investigating space radiation induced prevalence of murine Harderian gland (HG) tumorigenesis have been performed to help estimate GCR risks. Most studies used acute, relatively low fluence, exposures. Results on a broad spectrum of individual ions and linear energy transfers (LETs) have become available. However, in space, the crew are exposed simultaneously to many different GCR. Recent upgrades at the Brookhaven NASA Space Radiation Laboratory (NSRL) now allow mixtures in the form of different one-ion beams delivered in rapid sequence. This paper uses the results of three two-ion mixture experiments to illustrate conceptual, mathematical, computational, and statistical aspects of synergy analyses and also acts as an interim report on the mixture experiments' results. The results were interpreted using the following: (a) accumulated data from HG one-ion accelerator experiments; (b) incremental effect additivity synergy theory rather than simple effect additivity synergy theory; (c) parsimonious models for one-ion dose-effect relations; and (d), computer-implemented numerical methods encapsulated in freely available open source customized software. The main conclusions are the following. As yet, the murine HG tumorigenesis experimental studies show synergy in only one case out of three. Moreover, some theoretical arguments suggest GCR-simulating mixed beams are not likely to be synergistic. However, more studies relevant to possible synergy are needed by various groups that are studying various endpoints. Especially important is the possibility of synergy among high-LET radiations, since individual high-LET ions have large relative biological effectiveness for many endpoints. Selected terminology, symbols, and abbreviations. DER - dose-effect relation; E(d) - DER of a one-ion beam, where d is dose; HG prevalence p - in this paper, p is the number of mice with at least one Harderian gland tumor divided by the number of mice that are at risk of developing Harderian gland tumors (so that in this paper prevalence p can never, conceptually speaking, be greater than 1); IEA - incremental effect additivity synergy theory; synergy level - a specification, exemplified in Fig. 5, of how clear-cut an observed synergy is; mixmix principle - a consistency condition on a synergy theory which insures that the synergy theory treats mixtures of agent mixtures in a mathematically self-consistent way; NTE - non-targeted effect(s); NSNA - neither synergy nor antagonism; SEA - simple effect additivity synergy theory; TE - targeted effect(s); ß* - ion speed relative to the speed of light, with 0 < ß* < 1; SLI - swift light ion(s).


Assuntos
Transformação Celular Neoplásica/efeitos da radiação , Radiação Cósmica/efeitos adversos , Glândula de Harder/efeitos da radiação , Neoplasias Induzidas por Radiação , Animais , Carcinogênese , Simulação por Computador , Glândula de Harder/patologia , Transferência Linear de Energia , Camundongos , Modelos Teóricos , Aceleradores de Partículas , Prevalência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA