Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Nanobiotechnology ; 21(1): 320, 2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37679841

RESUMO

The utilization of nanomaterials in the biosensor field has garnered substantial attention in recent years. Initially, the emphasis was on enhancing the sensor current rather than material interactions. However, carbon nanotubes (CNTs) have gained prominence in glucose sensors due to their high aspect ratio, remarkable chemical stability, and notable optical and electronic attributes. The diverse nanostructures and metal surface designs of CNTs, coupled with their exceptional physical and chemical properties, have led to diverse applications in electrochemical glucose sensor research. Substantial progress has been achieved, particularly in constructing flexible interfaces based on CNTs. This review focuses on CNT-based sensor design, manufacturing advancements, material synergy effects, and minimally invasive/noninvasive glucose monitoring devices. The review also discusses the trend toward simultaneous detection of multiple markers in glucose sensors and the pivotal role played by CNTs in this trend. Furthermore, the latest applications of CNTs in electrochemical glucose sensors are explored, accompanied by an overview of the current status, challenges, and future prospects of CNT-based sensors and their potential applications.


Assuntos
Nanoestruturas , Nanotubos de Carbono , Glicemia , Automonitorização da Glicemia , Condutividade Elétrica
2.
Neurosurg Rev ; 45(2): 1451-1462, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34623525

RESUMO

OBJECTIVE: Skull base chordoma (SBC) is rare and one of the most challenging diseases to treat. We aimed to assess the optimal timing of adjuvant radiation therapy (RT) and to evaluate the factors that influence resection and long-term outcomes. METHODS: In total, 284 patients with 382 surgeries were enrolled in this retrospective study. Postsurgically, 64 patients underwent RT before recurrence (pre-recurrence RT), and 47 patients underwent RT after recurrence. During the first attempt to achieve gross-total resection (GTR), when the entire tumor was resected, 268 patients were treated with an endoscopic midline approach, and 16 patients were treated with microscopic lateral approaches. Factors associated with the success of GTR were identified using χ2 and logistic regression analyses. Risk factors associated with chordoma-specific survival (CSS) and progression-free survival (PFS) were evaluated with the Cox proportional hazards model. RESULTS: In total, 74.6% of tumors were marginally resected [GTR (40.1%), near-total resection (34.5%)]. History of surgery, large tumor volumes, and tumor locations in the lower clivus were associated with a lower GTR rate. The mean follow-up period was 43.9 months. At the last follow-up, 181 (63.7%) patients were alive. RT history, histologic subtype (dedifferentiated and sarcomatoid), non-GTR, no postsurgical RT, and the presence of metastasis were associated with poorer CSS. Patients with pre-recurrence RT had the longest PFS and CSS, while patients without postsurgical RT had the worst outcome. CONCLUSION: GTR is the goal of initial surgical treatment. Pre-recurrence RT would improve outcome regardless of GTR.


Assuntos
Cordoma , Neoplasias da Base do Crânio , Cordoma/patologia , Cordoma/cirurgia , Seguimentos , Humanos , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/cirurgia , Estudos Retrospectivos , Fatores de Risco , Neoplasias da Base do Crânio/patologia , Neoplasias da Base do Crânio/cirurgia , Resultado do Tratamento
3.
Sensors (Basel) ; 22(7)2022 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-35408374

RESUMO

Seed vigor is an important index to evaluate seed quality in plant species. How to evaluate seed vigor quickly and accurately has always been a serious problem in the seed research field. As a new physical testing method, multispectral technology has many advantages such as high sensitivity and accuracy, nondestructive and rapid application having advantageous prospects in seed quality evaluation. In this study, the morphological and spectral information of 19 wavelengths (365, 405, 430, 450, 470, 490, 515, 540, 570, 590, 630, 645, 660, 690, 780, 850, 880, 940, 970 nm) of alfalfa seeds with different level of maturity and different harvest periods (years), representing different vigor levels and age of seed, were collected by using multispectral imaging. Five multivariate analysis methods including principal component analysis (PCA), linear discriminant analysis (LDA), support vector machine (SVM), random forest (RF) and normalized canonical discriminant analysis (nCDA) were used to distinguish and predict their vigor. The results showed that LDA model had the best effect, with an average accuracy of 92.9% for seed samples of different maturity and 97.8% for seed samples of different harvest years, and the average sensitivity, specificity and precision of LDA model could reach more than 90%. The average accuracy of nCDA in identifying dead seeds with no vigor reached 93.3%. In identifying the seeds with high vigor and predicting the germination percentage of alfalfa seeds, it could reach 95.7%. In summary, the use of Multispectral Imaging and multivariate analysis in this experiment can accurately evaluate and predict the seed vigor, seed viability and seed germination percentages of alfalfa, providing important technical methods and ideas for rapid non-destructive testing of seed quality.


Assuntos
Germinação , Medicago sativa , Análise Discriminante , Sementes , Tecnologia
4.
Eur Radiol ; 31(11): 8197-8207, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33914116

RESUMO

OBJECTIVE: To evaluate the potential of diffusional variance decomposition (DIVIDE) for grading, molecular feature classification, and microstructural characterization of gliomas. MATERIALS AND METHODS: Participants with suspected gliomas underwent DIVIDE imaging, yielding parameter maps of fractional anisotropy (FA), mean diffusivity (MD), anisotropic mean kurtosis (MKA), isotropic mean kurtosis (MKI), total mean kurtosis (MKT), MKA/MKT, and microscopic fractional anisotropy (µFA). Tumor type and grade, isocitrate dehydrogenase (IDH) 1/2 mutant status, and the Ki-67 labeling index (Ki-67 LI) were determined after surgery. Statistical analysis included 33 high-grade gliomas (HGG) and 17 low-grade gliomas (LGG). Tumor diffusion metrics were compared between HGG and LGG, among grades, and between wild and mutated IDH types using appropriate tests according to normality assessment results. Receiver operating characteristic and Spearman correlation analysis were also used for statistical evaluations. RESULTS: FA, MD, MKA, MKI, MKT, µFA, and MKA/MKT differed between HGG and LGG (FA: p = 0.047; MD: p = 0.037, others p < 0.001), and among glioma grade II, III, and IV (FA: p = 0.048; MD: p = 0.038, others p < 0.001). All diffusion metrics differed between wild-type and mutated IDH tumors (MKI: p = 0.003; others: p < 0.001). The metrics that best discriminated between HGG and LGGs and between wild-type and mutated IDH tumors were MKT and FA respectively (area under the curve 0.866 and 0.881). All diffusion metrics except FA showed significant correlation with Ki-67 LI, and MKI had the highest correlation coefficient (rs = 0.618). CONCLUSION: DIVIDE is a promising technique for glioma characterization and diagnosis. KEY POINTS: • DIVIDE metrics MKI is related to cell density heterogeneity while MKA and µFA are related to cell eccentricity. • DIVIDE metrics can effectively differentiate LGG from HGG and IDH mutation from wild-type tumor, and showed significant correlation with the Ki-67 labeling index. • MKI was larger than MKA which indicates predominant cell density heterogeneity in gliomas. • MKA and MKI increased with grade or degree of malignancy, however with a relatively larger increase in the cell eccentricity metric MKA in relation to the cell density heterogeneity metric MKI.


Assuntos
Neoplasias Encefálicas , Glioma , Anisotropia , Neoplasias Encefálicas/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Glioma/diagnóstico por imagem , Glioma/genética , Humanos , Gradação de Tumores
5.
Soft Matter ; 17(39): 8786-8804, 2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34596200

RESUMO

To overcome the wearable sensor's defects and achieve the goal of robust mechanical properties, long-term adhesion, sensitive electrical conductivity, the multifunctional hydrogels were inspired by various mussels on the base of catechol and its analogues. In this review, we review the strategies for improving the mechanical strength, adhesion, conductivity and antibacterial properties of mussel-inspired hydrogels as bioelectronics. Double network structures, nanocomposites, supramolecular block polymers and other strategies were utilized for achieving tough hydrogels to prevent tensile fractures under high deformation. Many mussel-inspired chemistries were incorporated for constructing skin-attachable hydrogel strain sensors and some strategies for controlling the oxidation of catechol were employed to achieve long-term adhesion. In addition, electrolytes, conductive fillers, conductive polymers and their relevant hydrophilic modifications were introduced for fabricating the conductive hydrogel bioelectronics to enhance the conductivity properties. Finally, the challenges and outlooks in this promising field are featured from the perspective of materials chemistry.


Assuntos
Hidrogéis , Nanocompostos , Adesivos , Condutividade Elétrica , Cimentos de Resina
6.
BMC Cancer ; 20(1): 988, 2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33046024

RESUMO

BACKGROUND: Increasing studies have demonstrated that activated platelets play an essential role in tumour progression. However, the level and prognostic role of platelet indices in chordoma patients remain unclear. The aim of the current study was to characterize the prognostic performance of platelet count (PLT), mean platelet volume (MPV) and platelet distribution width (PDW) in skull base chordoma patients. METHODS: 187 primary skull base chordoma patients between January 2008 and September 2014 were enrolled in this retrospective study. The optimal cut-off values were determined by X-tile software, and the correlations between PLT, MPV, PDW and clinicopathological features were further analysed. Kaplan-Meier curve and Cox regression analysis were used for survival analysis. RESULTS: The values of preoperative PTL, MPV and PDW ranged from 104 to 501 × 109/L, 6.7 to 14.2 fl, and 7.8 to 26.2%, respectively. Elevated PLT was associated with larger tumour volume (p = 0.002). Kaplan-Meier survival analysis revealed that increased MPV and PDW were associated with shorter overall survival (p = 0.022 and 0.008, respectively). Importantly, multivariate Cox analysis demonstrated that elevated PDW was an independent unfavourable predictive factor for overall survival (hazard ratio (HR), 2.154, 95% confidence interval (CI), 1.258-3.688, p = 0.005). CONCLUSIONS: Our data show that elevated MPV and PDW are associated with poor outcomes in skull base chordoma and that PDW may be helpful to identify patients with high risk.


Assuntos
Biomarcadores Tumorais/metabolismo , Cordoma/sangue , Contagem de Plaquetas/métodos , Base do Crânio/patologia , Adulto , Feminino , Humanos , Masculino , Prognóstico , Estudos Retrospectivos
7.
J Magn Reson Imaging ; 50(1): 62-70, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30569494

RESUMO

BACKGROUND: Region-growing-based phase unwrapping methods have the potential for lossless phase aliasing removal, but generally suffer from unwrapping error propagation associated with discontinuous phase and/or long calculation times. The tradeoff point between robustness and efficiency of phase unwrapping methods in the region-growing category requires improvement. PURPOSE: To demonstrate an accurate, robust, and efficient region-growing phase unwrapping method for MR phase imaging applications. STUDY TYPE: Prospective. SUBJECTS, PHANTOM: normal human subjects (10) / brain surgery patients (2) / water phantoms / computer simulation. FIELD STRENGTH/SEQUENCE: 3 T/gradient echo sequences (2D and 3D). ASSESSMENT: A seed prioritized unwrapping (SPUN) method was developed based on single-region growing, prioritizing only a portion (eg, 100 seeds or 1% seeds) of available seed voxels based on continuity quality during each region-growing iteration. Computer simulation, phantom, and in vivo brain and pelvis scans were performed. The error rates, seed percentages, and calculation times were recorded and reported. SPUN unwrapped phase images were visually evaluated and compared with Laplacian unwrapped results. STATISTICAL TESTS: Monte Carlo simulation was performed on a 3D dipole phase model with a signal-to-noise ratio (SNR) of 1-9 dB, to obtain the mean and standard deviation of calculation error rates and calculation times. RESULTS: Simulation revealed a very robust unwrapping performance of SPUN, reaching an error rate of <0.4% even with SNR as low as 1 dB. For all in vivo data, SPUN was able to robustly unwrap the phase images of modest SNR and complex morphology with visually minimal errors and fast calculation speed (eg, <4 min for 368 × 312 × 128 data) when using a proper seed priority number, eg, Nsp = 1 or 10 voxels for 2D and Nsp = 1% for 3D data. DATA CONCLUSION: SPUN offers very robust and fast region-growing-based phase unwrapping, and does not require any tissue masking or segmentation, nor poses a limitation over imaging parameters. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:62-70.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Útero/diagnóstico por imagem , Adulto , Algoritmos , Hemorragia Cerebral/diagnóstico por imagem , Simulação por Computador , Feminino , Voluntários Saudáveis , Humanos , Imagens de Fantasmas , Estudos Prospectivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
8.
Angew Chem Int Ed Engl ; 58(48): 17328-17334, 2019 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-31591809

RESUMO

With their potential to offer new properties, single crystals containing nanoparticles provide an attractive class of nanocomposite materials. However, to fully profit from these, it is essential that we can characterise their 3D structures, identifying the locations of individual nanoparticles, and the defects present within the host crystals. Using calcite crystals containing quantum dots as a model system, we here use 3D stochastic optical reconstruction microscopy (STORM) to locate the positions of the nanoparticles within the host crystal. The nanoparticles are shown to preferentially associate with dislocations in a manner previously recognised for atomic impurities, rendering these defects visible by STORM. Our images also demonstrate that the types of dislocations formed at the crystal/substrate interface vary according to the nucleation face, and dislocation loops are observed that have entirely different geometries to classic misfit dislocations. This approach offers a rapid, easily accessed, and non-destructive method for visualising the dislocations present within crystals, and gives insight into the mechanisms by which additives become occluded within crystals.

9.
Faraday Discuss ; 179: 489-501, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25877254

RESUMO

Do the differing properties of materials influence their nucleation mechanisms? We present different experimental approaches to study and control nucleation, and shed light on some of the factors affecting the nucleation process.

10.
Clin Interv Aging ; 19: 339-346, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38434575

RESUMO

Background and Purpose: Studies on outcome comparison after endovascular treatment (EVT) for large vessel occlusion (LVO) between large artery atherosclerosis (LAA) and cardioembolism (CE) in the Asian population are scarce. We aimed to compare the baseline characteristics and clinical outcomes after EVT for anterior circulation LVO with LAA and CE in the Chinese population. Methods: Patients were selected from the ANGEL registry and divided into LAA and CE groups. The primary outcome was the 90-day modified Rankin Scale (mRS) 0-2. The secondary outcomes were 90-day mRS distribution, 90-day mRS 0-1, 90-day mRS 0-3, and early neurological improvement. The safety outcomes included death, symptomatic intracranial hemorrhage, and any intracranial hemorrhage. We conducted logistic regression models with adjustments to compare the outcomes. Results: A total of 632 patients were included, of whom, 488 were in the LAA group and 144 were in the CE group. No significant difference in 90-day mRS 0-2 was observed between LAA and CE groups (55.7%vs.43.1%, odds ratio[OR] 1.19, 95% confidence interval(CI), 0.92-1.53, P=0.190). The LAA group exhibited a higher frequency of mRS 0-3 compared to the CE group (69.1% vs 32.6%, OR1.32, 95% CI 1.02-1.72, P=0.038). However, the incidence of death within 90 days did not significantly differ between the LAA and CE groups (10.9%vs.24.3%, OR0.91, 95% CI0.66-1.25, P=0.545), nor did the occurrences of symptomatic intracranial hemorrhage(SICH) (4.5%vs.9.7%,OR1.08, 95% CI 0.65-1.78, P=0.779) or intracranial hemorrhage(ICH) (21.9%vs.30.6%, OR 0.94, 95% CI0.71-1.25, P=0.680). Moreover, no significant disparities were detected in other outcomes between the two groups (All P>0.05). Conclusion: In the ANGEL registry, a higher prevalence of patients undergoing EVT for acute anterior circulation LVO with LAA was found than those with CE. However, our study revealed that the efficacy and safety of EVT remained consistent regardless of the stroke's etiology such as LAA or CE.


Assuntos
Artérias , Aterosclerose , Humanos , Povo Asiático , Hemorragias Intracranianas/epidemiologia , Hemorragias Intracranianas/etiologia , China/epidemiologia
11.
Small Methods ; 8(1): e2301127, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37849248

RESUMO

Despite the tremendous progress in cancer treatment in recent decades, cancers often become resistant due to multiple mechanisms, such as intrinsic or acquired multidrug resistance, which leads to unsatisfactory treatment effects or accompanying metastasis and recurrence, ultimately to treatment failure. With a deeper understanding of the molecular mechanisms of tumors, researchers have realized that treatment designs targeting tumor resistance mechanisms would be a promising strategy to break the therapeutic deadlock. Nanodelivery systems have excellent physicochemical properties, including highly efficient tissue-specific delivery, substantial specific surface area, and controllable surface chemistry, which endow nanodelivery systems with capabilities such as precise targeting, deep penetration, responsive drug release, multidrug codelivery, and multimodal synergy, which are currently widely used in biomedical researches and bring a new dawn for overcoming cancer resistance. Based on the mechanisms of tumor therapeutic resistance, this review summarizes the research progress of nanodelivery systems for overcoming tumor resistance to improve therapeutic efficacy in recent years and offers prospects and challenges of the application of nanodelivery systems for overcoming cancer resistance.


Assuntos
Nanomedicina , Neoplasias , Humanos , Resistencia a Medicamentos Antineoplásicos , Sistemas de Liberação de Fármacos por Nanopartículas , Neoplasias/tratamento farmacológico , Falha de Tratamento
12.
J Am Soc Mass Spectrom ; 35(5): 951-959, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38597607

RESUMO

C-H bond ortho-substitution reaction has always been a significant and challenging topic in organic chemistry. We proposed a synthesis method based on microwave plasma torches. High-resolution mass spectrometry was used to monitor rapid reaction products. 2-Alkylbenzimidazole can be formed through the reaction of phenylnitrenium ion and nitriles on a millisecond scale. This reaction can achieve the one-step formation of benzimidazoles from benzene ring single-substituted compounds without the addition of external oxidants or catalysts. A similar C-H bond activation reaction can be accomplished with ketones. Meanwhile, the microwave plasma reactor was modified, and the resulting 2-methylbenzimidazole was successfully collected, indicating the device has good application potential in organic reactions such as C-H bond activation reaction.

13.
Quant Imaging Med Surg ; 14(5): 3655-3664, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38720833

RESUMO

Background: Although previous studies have shown that the injection of contrast agents can improve image quality, the specific impact of this on T2-weighted fat-suppressed (T2 FS) and diffusion-weighted imaging (DWI) sequences in the diagnosis of breast cancer remains incompletely understood. In particular, there is insufficient research on how contrast agents affect the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values within these sequences, and how these changes influence the diagnosis of benign and malignant breast tumors. Methods: Breast magnetic resonance images (MRI) were obtained from 178 consecutive patients on a 3T scanner. The SNR and CNR of lesions on T2 FS sequence were calculated before and after contrast agent injection and compared. Differences between pre- and post-contrast ADC in identifying different tumor types were compared using the Kruskal-Wallis H-test and the paired comparison test. The accuracy of ADC values between pre- and post-contrast in distinguishing benign and malignant breast masses was assessed using receiver operating characteristic (ROC) curves. Results: The SNR and CNR of T2 FS sequence increased after contrast injection, and especially for invasive cancer and benign tumor, the increase was significant. For DWI, there was a slight increase or decrease of ADC values after contrast injection, but the ADC values before and after contrast had a similar effect in identifying different types of tumors. In the ROC curve analysis for assessing benign and malignant breast tumors, the area under the curve (AUC) before and after contrast showed similar results. Conclusions: Contrast agent injection can improve the SNR and CNR of T2 FS sequence, thus providing higher quality images for the diagnosis of breast lesions. Furthermore, injection of contrast agent had little effect on the ability of ADC values to identify different types of lesions and both ADC values before and after the contrast agent were able to distinguish between benign and malignant tumors with almost the same accuracy.

14.
Front Cardiovasc Med ; 11: 1286271, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38347952

RESUMO

Background: Due to its potential to significantly reduce scanning time while delivering accurate results for cardiac volume function, compressed sensing (CS) has gained traction in cardiovascular magnetic resonance (CMR) cine. However, further investigation is necessary to explore its feasibility and impact on myocardial strain results. Materials and methods: A total of 102 participants [75 men, 46.5 ± 17.1 (SD) years] were included in this study. Each patient underwent four consecutive cine sequences with the same slice localization, including the reference multi-breath-hold balanced steady-state free precession (bSSFPref) cine, the CS cine with the same flip angle as bSSFPref before (CS45) and after (eCS45) contrast enhancement, and the CS cine (eCS70) with a 70-degree flip angle after contrast enhancement. Biventricular strain parameters were derived from cine images. Two-tailed paired t-tests were used for data analysis. Results: Global radial strain (GRS), global circumferential strain (GCS), and global longitudinal strain (GLS) were observed to be significantly lower in comparison to those obtained from bSSFPref sequences for both the right and left ventricles (all p < 0.001). No significant difference was observed on biventricular GRS-LAX (long-axis) and GLS values derived from enhanced and unenhanced CS cine sequences with the same flip angle, but remarkable reductions were noted in GRS-SAX (short-axis) and GCS values (p < 0.001). After contrast injection, a larger flip angle caused a significant elevation in left ventricular strain results (p < 0.001) but did not affect the right ventricle. The increase in flip angle appeared to compensate for contrast agent affection on left ventricular GRS-SAX, GCS values, and right ventricular GRS-LAX, GLS values. Conclusion: Despite incorporating gadolinium contrast agents and applying larger flip angles, single breath-hold CS cine sequences consistently yielded diminished strain values for both ventricles when compared with conventional cine sequences. Prior to employing this single breath-hold CS cine sequence to refine the clinical CMR examination procedure, it is crucial to consider its impact on myocardial strain results.

15.
Quant Imaging Med Surg ; 13(3): 1699-1710, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36915316

RESUMO

Background: Dark blood T2-weighted (DB-T2W) imaging is widely used to evaluate myocardial edema in myocarditis and inflammatory cardiomyopathy. However, this technique is sensitive to arrhythmia, tachycardia, and cardiac and respiratory motion due to the long scan time with multiple breath-holds. The application of artificial intelligence (AI)-assisted compressed sensing (ACS) has facilitated significant progress in accelerating medical imaging. However, the effect of DB-T2W imaging on ACS has not been elucidated. This study aimed to examine the effects of ACS on the image quality of single-shot and multi-shot DB-T2W imaging of edema. Methods: Thirty-three patients were included in this study and received DB-T2W imaging with ACS, including single-shot acquisition (SS-ACS) and multi-shot acquisition (MS-ACS). The resulting images were compared with those of the conventional multi-shot DB-T2W imaging with parallel imaging (MS-PI). Quantitative assessments of the signal-to-noise ratio (SNR), tissue contrast ratio (CR), and contrast-to-noise ratio (CNR) were performed. Three radiologists independently evaluated the overall image quality, blood nulling, free wall of the left ventricle, free wall of the right ventricle, and interventricular septum using a 5-point Likert scale. Results: The total scan time of the DB-T2W imaging with ACS was significantly reduced compared to the conventional parallel imaging [number of heartbeats (SS-ACS:MS-ACS:MS-PI) =19:63:99; P<0.001]. The SNRmyocardium and CNRblood-myocardium of MS-ACS and SS-ACS were higher than those of MS-PI (all P values <0.01). Furthermore, the CRblood-myocardium of SS-ACS was also higher than that of MS-PI (P<0.01). There were significant differences in overall image quality, blood nulling, left ventricle free wall visibility, and septum visibility between the MS-PI, MS-ACS, and SS-ACS protocols (all P values <0.05). Moreover, blood in the heart was better nulled using SS-ACS (P<0.01). Conclusions: The ACS method shortens the scan time of DB-T2W imaging and achieves comparable or even better image quality compared to the PI method. Moreover, DB-T2W imaging using the ACS method can reduce the number of breath-holds to 1 with single-shot acquisition.

16.
Quant Imaging Med Surg ; 13(5): 3222-3240, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37179946

RESUMO

Background: We aimed to demonstrate the feasibility of generating high-resolution human brain magnetic resonance imaging (MRI) at 5 Tesla (T) using a quadrature birdcage transmit/48-channel receiver coil assembly. Methods: A quadrature birdcage transmit/48-channel receiver coil assembly was designed for human brain imaging at 5T. The radio frequency (RF) coil assembly was validated by electromagnetic (EM) simulations and phantom imaging experimental studies. The simulated B1+ field inside a human head phantom and inside a human head model generated by the birdcage coils driven in circularly polarized (CP) mode at 3T, 5T and 7T was compared. Signal-to-noise ratio (SNR) maps, the inverse g-factor maps for evaluation of parallel imaging performance, anatomic images, angiography images, vessel wall images and susceptibility weighted images (SWI) were acquired using the RF coil assembly at 5T and compared to those acquired using a 32-channel head coil on a 3T MRI scanner. Results: For the EM simulations, 5T MRI provided less RF inhomogeneity compared to that of 7T. In the phantom imaging study, the distributions of the measured B1+ field were consistent with the distributions of the simulated B1+ field. In the human brain imaging study, the average SNR value of the brain in the transversal plane at 5T was 1.6 times of that at 3T. The 48-channel head coil at 5T had higher parallel acceleration capability than the 32-channel head coil at 3T. The anatomic images at 5T also showed higher SNR than those at 3T. Improved delineation of the hippocampus, lenticulostriate arteries, and basilar arteries was observed at 5T compared to 3T. SWI with a higher resolution of 0.3 mm ×0.3 mm ×1.2 mm could be acquired at 5T, which enabled better visualization of small blood vessels compared to that at 3T. Conclusions: 5T MRI can provide significant SNR improvement compared to that of 3T with less RF inhomogeneity than that of 7T. The ability to obtain high quality in vivo human brain images at 5T using the quadrature birdcage transmit/48-channel receiver coil assembly has significant in clinical and scientific research applications.

17.
Medicine (Baltimore) ; 101(47): e31858, 2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-36451436

RESUMO

The incidence of endometrial adenocarcinoma (EA) has increased worldwide in recent years due to the widespread use of estrogen therapy and the overall increase in life expectancy. However, we know of no sensitive molecular index that can be used to predict the onset of EA, evaluate the therapeutic effects of treatment agents, or provide prognostic benefit in post-treatment follow-up. To explore the correlation between human olfactomedin 4 (OLFM4) and the clinicopathologic parameters of EA, and to determine the precise involvement of OLFM4 as a related factor in the occurrence and development of EA. We enrolled 61 gynecologic patients for a retrospective study at the Tai'an Central Hospital of Shandong Province from January 1, 2016, to June 30, 2022. We determined the expression levels of estrogen receptor α (ERα), progesterone receptor (PR), and OLFM4 proteins in endometrial tissue with the immunohistochemical S-P staining method, and analyzed the correlations among ERα, PR, and OLFM4 protein expression levels and with the pathologic stage, histologic grade, myometrial invasiveness, and lymphatic metastasis of EA. The expression levels of OLFM4 in EA were higher than in normal endometrium (P = .036). The expression level of OLFM4 protein in stage II-III patients was higher than that in stage I patients (P = .034), and the expression levels of ERα and PR proteins in EA were lower than those in normal endometrial tissue (P = .014 and P = .0005). While we observed no correlation in endometrial tissues of disparate pathologic types between OLFM4 and the expression levels of ERα and PR proteins, we noted a positive correlation between the expression levels of ERα and PR protein. The expression level of OLFM4 protein increased with the malignant degree of endometrial lesions and OLFM4 protein expression was related to the FIGO stage of EA. And OLFM4 protein can be used as 1 of the potential diagnostic factors for endometrial lesions, which is worthy of further study.


Assuntos
Adenocarcinoma , Receptor alfa de Estrogênio , Humanos , Feminino , Estudos Retrospectivos , Epitélio , Terapia de Reposição Hormonal , Fator Estimulador de Colônias de Granulócitos
18.
Med Phys ; 49(1): 129-143, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34748660

RESUMO

PURPOSE: Cardiovascular magnetic resonance (CMR) is a vital diagnostic tool in the management of cardiovascular diseases. The advent of advanced CMR technologies combined with artificial intelligence (AI) has the potential to simplify imaging, reduce image acquisition time without compromising image quality (IQ), and improve magnetic field uniformity. Here, we aim to implement two AI-based deep learning techniques for automatic slice alignment and cardiac shimming and evaluate their performance in clinical cardiac magnetic resonance imaging (MRI). METHODS: Two deep neural networks were developed, trained, and validated on pre-acquired cardiac MRI datasets (>500 subjects) to achieve automatic slice planning and shimming (implemented in the scanner) for CMR. To examine the performance of our automated cardiac planning (EasyScan) and AI-based shim (AI shim), two prospective studies were performed subsequently. For the EasyScan validation, 10 healthy subjects underwent two identical CMR protocols: with manual cardiac planning and with AI-based EasyScan to assess protocol scan time difference and accuracy of cardiac plane prescriptions on a 1.5 T clinical MRI scanner. For the AI shim validation, a total of 20 subjects were recruited: 10 healthy and 10 cardio-oncology patients with referrals for a CMR examination. Cine images were obtained with standard cardiac volume shim and with AI shim to assess signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), overall IQ (sharpness and MR image degradation), ejection fraction (EF), and absolute wall thickening. A hybrid statistical method using of nonparametric (Wilcoxon) and parametric (t-test) assessments was employed for statistical analyses. RESULTS: CMR protocol with AI-based plane prescriptions, EasyScan, minimized operator dependence and reduced overall scanning time by over 2 min (∼13 % faster, p < 0.001) compared to the protocol with manual cardiac planning. EasyScan plane prescriptions also demonstrated more accurate (less plane angulation errors from planes manually prescribed by a certified cardiac MRI technologist) cardiac planes than previously reported strategies. Additionally, AI shim resulted in improved B0 field homogeneity. Cine images obtained with AI shim revealed a significantly higher SNR (12.49%; p = 0.002) than those obtained with volume shim (volume shim: 32.90 ± 7.42 vs. AI shim: 37.01 ± 8.87) for the left ventricle (LV) myocardium. LV myocardium CNR was 12.48% higher for cine imaging with AI shim (149.02 ± 39.15) than volume shim (132.49 ± 33.94). Images obtained with AI shim resulted in sharper images than those obtained with volume shim (p = 0.012). The LVEF and absolute wall thickening also showed that differences exist between the two shimming methods. The LVEF by AI shim was shown to be slightly larger than LVEF by volume shim in two groups: 2.87% higher with AI shim for the healthy group and 1.70% higher with AI shim for the patient group. The LV absolute wall thickening (in mm) also showed that differences exist between shimming methods for each group with larger changes observed in the patient group (healthy: 3.31%, p = 0.234 and patient group: 7.29%, p = 0.059). CONCLUSIONS: CMR exams using EasyScan for cardiac planning demonstrated accelerated cardiac exam compared to the CMR protocol with manual cardiac planning. Improved and more uniform B0 magnetic field homogeneity also achieved using AI shim technique compared to volume shimming.


Assuntos
Inteligência Artificial , Imageamento por Ressonância Magnética , Coração/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética , Estudos Prospectivos , Reprodutibilidade dos Testes , Volume Sistólico
19.
Talanta ; 249: 123674, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35717753

RESUMO

Glycans are the most abundant organic polymers in nature. They are essential to living organisms and regulate a wide range of biological functions. However, mass spectrometry-based identification of glycan isomers remains challenging due to the complexity of their structures including their complex compositions, linkages, and anomeric configurations. In this study, two novel complex ions, the mononuclear copper-bound dimeric ions [(Cu2+)(A)(L-His)-H]+ and the mononuclear copper-bound quaternary ions [(Cu2+)(A)(L-Ser)3-H]+ (where A denotes a disaccharide, and L-Ser/His denotes l-serine/histidine), were designed for the collision-induced dissociation-based identification and relative quantification of 14 disaccharide isomers. When the unique fragmentation patterns of the above two types of complex ions were mapped into a three-dimensional vector, all the isomers were completely distinguished. Of note, the established method is able to identify mixtures of linkage isomers only using tandem mass spectrometry based on linkage-specific fragment ions of histidine-based complex ions. Finally, the method was successfully applied to the identification and relative quantification of two disaccharide isomers (lactose and sucrose) in dairy beverages. In conclusion, the established method is sensitive to subtle structural differences in disaccharide isomers and has the potential to be used for the differentiation of various glycans.


Assuntos
Dissacarídeos , Espectrometria de Massas em Tandem , Cobre , Dissacarídeos/análise , Dissacarídeos/química , Histidina , Íons , Isomerismo , Polissacarídeos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos
20.
Adv Sci (Weinh) ; : e2203759, 2022 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-36403251

RESUMO

Calcium carbonate biomineralization is remarkable for the ability of organisms to produce calcite or aragonite with perfect fidelity, where this is commonly attributed to specific anionic biomacromolecules. However, it is proven difficult to mimic this behavior using synthetic or biogenic anionic organic molecules. Here, it is shown that cationic polyamines ranging from small molecules to large polyelectrolytes can exert exceptional control over calcium carbonate polymorph, promoting aragonite nucleation at extremely low concentrations but suppressing its growth at high concentrations, such that calcite or vaterite form. The aragonite crystals form via particle assembly, giving nanoparticulate structures analogous to biogenic aragonite, and subsequent growth yields stacked aragonite platelets comparable to structures seen in developing nacre. This mechanism of polymorph selectivity is captured in a theoretical model based on these competing nucleation and growth effects and is completely distinct from the activity of magnesium ions, which generate aragonite by inhibiting calcite. Profiting from these contrasting mechanisms, it is then demonstrated that polyamines and magnesium ions can be combined to give unprecedented control over aragonite formation. These results give insight into calcite/aragonite polymorphism and raise the possibility that organisms may exploit both amine-rich organic molecules and magnesium ions in controlling calcium carbonate polymorph.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA