RESUMO
BACKGROUND: A novel automated method for measuring left ventricular (LV) global longitudinal strain (GLS) along the endocardium has advantages in terms of its rapid application and excellent reproducibility. However, it remains unclear whether the available normal range for conventional GLS using the manual method is applicable to the automated GLS method. This study aimed to compare automated GLS head-to-head with manual layer-specific GLS, and to identify whether a specialized normal reference range for automated GLS is needed and explore the main determinants. METHODS: In total, 1683 healthy volunteers (men, 43%; age, 18-80 years) were prospectively enrolled from 55 collaborating laboratories. LV GLS was measured using both manual layer-specific and automated methods. RESULTS: Automated GLS was higher than endocardial, mid-myocardial, and epicardial GLS. Women had a higher automated GLS than men. GLS had no significant age dependency in men, but first increased and then decreased with age in women. Accordingly, sex- and age-specific normal ranges for automated GLS were proposed. Moreover, GLS appeared to have different burdens in relation to dominant determinants between the sexes. GLS in men showed no dominant determinants; however, GLS in women correlated with age, body mass index, and heart rate. CONCLUSIONS: Using the novel automated method, was LV GLS higher than when using the manual GLS method. The normal ranges of automated GLS stratified according to sex and age were provided, with dominant determinants showing sex disparities that require full consideration in clinical practice.
Assuntos
Ecocardiografia , Deformação Longitudinal Global , Masculino , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Valores de Referência , Ecocardiografia/métodos , Função Ventricular Esquerda/fisiologia , Reprodutibilidade dos TestesRESUMO
AIMS: Mitral annular plane systolic excursion (MAPSE) is a simple and reliable index for evaluating left ventricular (LV) systolic function, particularly in patients with poor image quality; however, the lack of reference values limits its widespread use. This study aimed to establish the normal ranges for MAPSE measured using motion-mode (M-mode) and two-dimensional speckle tracking echocardiography (2D-STE) and to explore its principal determinants. METHODS AND RESULTS: This multicentre, prospective, cross-sectional study included 1952 healthy participants [840 men (43%); age range, 18-80 years] from 55 centres. MAPSE was measured using M-mode echocardiography and 2D-STE. The results showed that women had a higher MAPSE than men and MAPSE decreased with age. The age- and sex-specific reference values for MAPSE were established for these two methods. Multiple linear regression analyses revealed that MAPSE on M-mode echocardiography correlated with age and MAPSE on 2D-STE with age, blood pressure (BP), heart rate, and LV volume. Moreover, MAPSE measured by 2D-STE correlated more strongly with global longitudinal strain compared with that measured using M-mode echocardiography. CONCLUSION: Normal MAPSE reference values were established based on age and sex. BP, heart rate, and LV volume are potential factors that influence MAPSE and should be considered in clinical practice. Normal values are useful for evaluating LV longitudinal systolic function, especially in patients with poor image quality, and may further facilitate the use of MAPSE in routine assessments.