RESUMO
BACKGROUND: Laparoscopic colorectal cancer surgery increases the risk of incisional hernia (IH) at the tumor extraction site. AIM: To investigate the incidence of IH at extraction sites following laparoscopic colorectal cancer surgery and identify the risk factors for IH incidence. METHODS: This study retrospectively analyzed the data of 1614 patients who underwent laparoscopic radical colorectal cancer surgery with tumor extraction through the abdominal wall at our center between January 2017 and December 2022. Differences in the incidence of postoperative IH at different extraction sites and the risk factors for IH incidence were investigated. RESULTS: Among the 1614 patients who underwent laparoscopic radical colorectal cancer surgery, 303 (18.8%), 923 (57.2%), 171 (10.6%), and 217 (13.4%) tumors were extracted through supraumbilical midline, infraumbilical midline, umbilical, and off-midline incisions. Of these, 52 patients developed IH in the abdominal wall, with an incidence of 3.2%. The incidence of postoperative IH was significantly higher in the off-midline incision group (8.8%) than in the middle incision groups [the supraumbilical midline (2.6%), infraumbilical midline (2.2%), and umbilical incision (2.9%) groups] (χ2 = 24.985; P < 0.05). Univariate analysis showed that IH occurrence was associated with age, obesity, sex, chronic cough, incision infection, and combined diabetes, anemia, and hypoproteinemia (P < 0.05). Similarly, multivariate analysis showed that off-midline incision, age, sex (female), obesity, incision infection, combined chronic cough, and hypoproteinemia were independent risk factors for IH at the site of laparoscopic colorectal cancer surgery (P < 0.05). CONCLUSION: The incidence of postoperative IH differs between extraction sites for laparoscopic colorectal cancer surgery. The infraumbilical midline incision is associated with a lower hernia rate and is thus a suitable tumor extraction site.
RESUMO
In this study, we have effectively prepared a novel fluorescent probe named HDXM based on benzopyran derivatives for the ultrafast detection (within 3 s) of SO2 derivatives or biogenic amines. HDXM showed a noticeable color change after the addition of SO2 derivatives (from purple to colorless) or biogenic amines (from purple to blue), indicating that HDXM can identify two analytes with the naked eye. It is worth noting that HDXM can be used to detect SO2 derivatives in actual sugar samples, and to image HSO3-/SO32- in living cells. More importantly, sensing labels (HDXM-loaded filter paper or agarose hydrogel) enable real-time visual monitoring of salmon freshness through colorimetric and fluorescence dual channels. Compared with the Chinese national standard method, the sensing label is an effective tool for evaluating the freshness of fish. Benefiting from its excellent solubility and fluorescence performance, HDXM can be used as a versatile fluorescent material in various applications, including flexible films, glass coatings, impregnating dyes, printing, and fingerprint ink. HDXM is expected to be a promising and valuable multifunctional tool for food safety and fluorescent materials.
Assuntos
Aminas Biogênicas , Corantes Fluorescentes , Animais , Fluorescência , Alimentos Marinhos/análise , Carboidratos , PeixesRESUMO
Peroxynitrite (ONOO-) and cell plasma membrane (CPM) are two key factors in cell pyroptosis during the progression of abdominal aortic aneurysm (AAA). However, their combined temporal and spatial roles in initiating AAA pathogenesis remain unclear. Herein, we developed a two-photon fluorescence probe, BH-Vis, enabling real-time dynamic detection of CPM and ONOO- changes, and revealing their interplay in AAA. BH-Vis precisely targets CPM with reduced red fluorescence intensity correlating with diminished CPM tension. Concurrently, a blue shift of the fluorescence signal of BH-Vis occurs in response to ONOO- offering a reliable ratiometric detection mode with enhanced accuracy by minimizing external testing variables. More importantly, two photon confocal imaging with palmitic acid (PA) and ganglioside (GM1) manipulation, which modulating cell pyroptosis, showcases reliable fluorescence fluctuations. This groundbreaking application of BH-Vis in a mouse AAA model demonstrates its significant potential for accurately identifying cell pyroptosis levels during AAA development.
Assuntos
Aneurisma da Aorta Abdominal , Membrana Celular , Imagem Óptica , Ácido Peroxinitroso , Aneurisma da Aorta Abdominal/metabolismo , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/patologia , Ácido Peroxinitroso/metabolismo , Animais , Camundongos , Membrana Celular/metabolismo , Membrana Celular/química , Humanos , Corantes Fluorescentes/química , Piroptose/efeitos dos fármacos , Camundongos Endogâmicos C57BL , Masculino , FótonsRESUMO
Due to increasing food safety issues, developing intelligent, on-site, and visual methods for detecting fish freshness has attracted significant attention. Here, we have prepared a benzo[h]chromene derivative BCN that can visually detect 12 biogenic amines (BAs) with high sensitivity. The mechanism for recognizing cadaverine (Cad) is that the probe reacts with Cad to produce a Schiff base derivative, which alters the charge distribution within the molecule, resulting in significant colorimetric and fluorescence changes. The sensing label BCN/FPS was prepared by loading the probe BCN on filter paper, and a visual detection platform was constructed by combining it with a smartphone. By monitoring the correspondence between label color and TVB-N content, a working curve of (R + B)/(R + B + G) with TVB-N content was obtained, enabling visual evaluation of salmon freshness using only a mobile phone. In addition, based on the good solubility and processability of BCN, its application in fluorescent dyes including impregnating dyes, printing inks, coatings, and flexible films has been explored, which opens up new directions for the application of BCN. Therefore, BCN has the potential for real-time monitoring of meat freshness and preparation of fluorescent materials.
RESUMO
A simple benzopyran-based fluorescence probe DCA-Apa detection of volatile amine has been synthesized. DCA-Apa can recognize volatile amines by dual channel mode (changing from blue to light yellow in sunlight, and from weak pink to orange under 365 nm) in pure water system. DCA-Apa has the advantages of ultra-fast response (â¼6 s), NIR emission (655 nm), and a good fluorescence response for many amines. The sensing label or gel loaded with DCA-Apa was prepared by the dipping or mixing method using filter paper or gelatin as solid carriers, which can identify volatile amine vapor and monitor the freshness of salmon by colorimetric and fluorescent dual channels. When the color of the label changes to light yellow-green or the fluorescence of the label becomes orange fluorescence (365 nm UV lamp), it indicates that the fish has rotted. The two-channel method makes up for the deficiency of the single colorimetric method, and establishes a theoretical foundation for more precise assessment of fish freshness.
Assuntos
Aminas , Corantes Fluorescentes , Alimentos Marinhos , Espectrometria de Fluorescência , Animais , Aminas/química , Aminas/análise , Colorimetria/métodos , Peixes , Corantes Fluorescentes/química , Géis/química , Salmão , Espectrometria de Fluorescência/métodos , Compostos Orgânicos Voláteis/análise , Alimentos Marinhos/normasRESUMO
As an important ROS species participating in various physiological and pathological processes, high level of hypochlorite (ClO-) poses significant health and safety concerns, necessitating efficient detection methods. Herein, this study introduces a water-soluble fluorescent nanoprobe Nano-SJD, effectively detect ClO- in both food samples and living cells. The small molecular probe SJD with N, N-dimethylthiocarbamyl (DMTC) as recognition moiety was constructed based on a naphthalene derivative. To further improve the water solubility, SJD was assembled with an amphiphilic copolymer (mPEG-DSPE) to prepare a water soluble fluorescent nanoprobe Nano-SJD. Fortunately, the nanoprobe preserves the excellent properties of small molecules and performs very well optical response to ClO- in aqueous solution, possessing the advantages including ultra-rapid response (within 1 s), minimal interference, low detection limits (0.39 µM) and good pH stability. What's more important, we have also developed smartphone-compatible test paper strips for convenient on-site detection of ClO- in real-water samples. Additionally, the robust fluorescent imaging behavior of Nano-SJD for visualization of ClO- in living cells highlights its broad potential in biosystem applicability.