Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Chem Soc Rev ; 53(10): 5291-5337, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38634467

RESUMO

Rechargeable batteries, typically represented by lithium-ion batteries, have taken a huge leap in energy density over the last two decades. However, they still face material/chemical challenges in ensuring safety and long service life at temperatures beyond the optimum range, primarily due to the chemical/electrochemical instabilities of conventional liquid electrolytes against aggressive electrode reactions and temperature variation. In this regard, a gel polymer electrolyte (GPE) with its liquid components immobilized and stabilized by a solid matrix, capable of retaining almost all the advantageous natures of the liquid electrolytes and circumventing the interfacial issues that exist in the all-solid-state electrolytes, is of great significance to realize rechargeable batteries with extended working temperature range. We begin this review with the main challenges faced in the development of GPEs, based on extensive literature research and our practical experience. Then, a significant section is dedicated to the requirements and design principles of GPEs for wide-temperature applications, with special attention paid to the feasibility, cost, and environmental impact. Next, the research progress of GPEs is thoroughly reviewed according to the strategies applied. In the end, we outline some prospects of GPEs related to innovations in material sciences, advanced characterizations, artificial intelligence, and environmental impact analysis, hoping to spark new research activities that ultimately bring us a step closer to realizing wide-temperature rechargeable batteries.

2.
BMC Psychiatry ; 24(1): 324, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664669

RESUMO

BACKGROUND: Methamphetamine (MA) abuse has resulted in a plethora of social issues. Sleep disturbance is a prominent issue about MA addiction, which serve as a risk factor for relapse, and the gut microbiota could play an important role in the pathophysiological mechanisms of sleep disturbances. Therefore, improving sleep quality can be beneficial for treating methamphetamine addiction, and interventions addressing the gut microbiota may represent a promising approach. METHOD: We recruited 70 MA users to investigate the associations between sleep quality and fecal microbiota by the Pittsburgh Sleep Quality Index (PSQI), which was divided into MA-GS (PSQI score < 7, MA users with good sleep quality, n = 49) and MA-BS group (PSQI score ≥ 7, MA users with bad sleep quality, n = 21). In addition, we compared the gut microbiota between the MA-GS and healthy control (HC, n = 38) groups. 16S rRNA sequencing was applied to identify the gut bacteria. RESULT: The study revealed that the relative abundances of the Thermoanaerobacterales at the order level differed between the MA-GS and MA-BS groups. Additionally, a positive correlation was found between the relative abundance of the genus Sutterella and daytime dysfunction. Furthermore, comparisons between MA users and HCs revealed differences in beta diversity and relative abundances of various bacterial taxa. CONCLUSION: In conclusion, the study investigated alterations in the gut microbiota among MA users. Furthermore, we demonstrated that the genus Sutterella changes may be associated with daytime dysfunction, suggesting that the genus Sutterella may be a biomarker for bad sleep quality in MA users.


Assuntos
Transtornos Relacionados ao Uso de Anfetaminas , Fezes , Microbioma Gastrointestinal , Metanfetamina , Qualidade do Sono , Humanos , Microbioma Gastrointestinal/efeitos dos fármacos , Microbioma Gastrointestinal/fisiologia , Metanfetamina/efeitos adversos , Masculino , Adulto , Fezes/microbiologia , Feminino , RNA Ribossômico 16S/genética , Adulto Jovem , Transtornos do Sono-Vigília/microbiologia
3.
BMC Psychiatry ; 24(1): 387, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38783266

RESUMO

BACKGROUND: Low concentrations of S100B have neurotrophic effects and can promote nerve growth and repair, which plays an essential role in the pathophysiological and histopathological alterations of major depressive disorder (MDD) during disease development. Studies have shown that plasma S100B levels are altered in patients with MDD. In this study, we investigated whether the plasma S100B levels in MDD differ between genders. METHODS: We studied 235 healthy controls (HCs) (90 males and 145 females) and 185 MDD patients (65 males and 120 females). Plasma S100B levels were detected via multifactor assay. The Mahalanobis distance method was used to detect the outliers of plasma S100B levels in the HC and MDD groups. The Kolmogorov-Smirnov test was used to test the normality of six groups of S100B samples. The Mann-Whitney test and Scheirer-Ray-Hare test were used for the comparison of S100B between diagnoses and genders, and the presence of a relationship between plasma S100B levels and demographic details or clinical traits was assessed using Spearman correlation analysis. RESULTS: All individuals in the HC group had plasma S100B levels that were significantly greater than those in the MDD group. In the MDD group, males presented significantly higher plasma S100B levels than females. In the male group, the plasma S100B levels in the HC group were significantly higher than those in the MDD group, while in the female group, no significant difference was found between the HC and MDD groups. In the male MDD subgroup, there was a positive correlation between plasma S100B levels and years of education. In the female MDD subgroup, there were negative correlations between plasma S100B levels and age and suicidal ideation. CONCLUSIONS: In summary, plasma S100B levels vary with gender and are decreased in MDD patients, which may be related to pathological alterations in glial cells.


Assuntos
Transtorno Depressivo Maior , Subunidade beta da Proteína Ligante de Cálcio S100 , Humanos , Transtorno Depressivo Maior/sangue , Masculino , Feminino , Subunidade beta da Proteína Ligante de Cálcio S100/sangue , Adulto , Fatores Sexuais , Pessoa de Meia-Idade , Caracteres Sexuais , Biomarcadores/sangue , Estudos de Casos e Controles
4.
J Appl Clin Med Phys ; 25(4): e14167, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37812733

RESUMO

PURPOSE: Optimizing CT protocols is challenging in the presence of automatic dose modulation because the CT dose index (CTDIvol) at different patient sizes is unknown to the operator. The task is more difficult when both the image quality index and iterative reconstruction prospectively affect the dose determination. It is of interest in practice to be informed of the CTDIvol during the protocol initialization and evaluation. It was our objective to obtain a predictive relationship between CTDIvol, the image quality index, and iterative reconstruction strength at various patient sizes. METHODS: Dose modulation data were collected on a GE Revolution 256-slice scanner utilizing a Mercury phantom and selections of the noise index (NI) from 8 to 17, the third generation iterative reconstruction (ASIR-V) from 0% to 80%, and phantom diameters from 16 to 36 cm. The fixed parameters were 120 kVp, a pitch of .984, and a collimation of 40 mm with a primary slice width of 2.5 mm. The CTDIvol per diameter was based on the average tube current over three adjacent slices (same or similar diameter) multiplied by a conversion factor between the average mA of the series and the reported CTDIvol. The relationship between CTDIvol, NI, and ASIR-V for each diameter was fitted with a 2nd order polynomial of ASIR-V multiplied by a power law of NI. RESULTS: The ASIR-V fit parameters versus diameter followed a Lorentz function while the NI exponent versus diameter followed an exponential growth function. The CTDIvol predictions were accurate within 15% compared to phantom results on a separate GE Revolution. For clinical relevance, the phantom diameter was converted to an abdomen or chest equivalent diameter and was well matched to patient data. CONCLUSION: The fitted relationship for CTDIvol. for given values of NI and ASIR-V blending for a range of phantom sizes was a good match to phantom and patient data. The results can be of direct help for selecting adequate parameters in CT protocol development.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Algoritmos
5.
Perfusion ; : 2676591231189941, 2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37498618

RESUMO

BACKGROUND: The effectiveness of a concomitant intra-aortic balloon pump (IABP) with veno-arterial extracorporeal membrane oxygenation (VA-ECMO) intervention in acute myocardial infarction with cardiogenic shock (AMICS) patients is contested in the literature. This study sought to compare short-term mortality weaning rate from VA-ECMOin AMICS cases. METHODS: We conducted a literature review and compared the primary and secondary endpoints in the following treatment groups of AMICS patients: (1) VA-ECMO plus IABP vs. IABP alone and (2) VA-ECMO plus IABP vs. VA-ECMO alone. The primary endpoint was in-hospital all-cause mortality; while 30-days mortality, weaning from VA-ECMO, and vascular complications comprised secondary endpoints. RESULTS: VA-ECMO concomitant with IABP was administered to 3,580 (76.4%) patients, while IABP alone and VA-ECMO alone treatments accounted for 1.7% and 21.9% of the patients, respectively. We found that in-hospital mortality was significantly lower in patients treated with VA-ECMO plus IABP vs. VA-ECMO alone (odds ratio (OR) = 0.52; 95% Confidence Interval (CI) = 0.21-1.31; I-squared statistic (I2 = 30%) or IABP alone (OR = 0.20; 95% CI = 0.08-0.55; I2 = 0%). Additionally, 30-days mortality was significantly lower in patients treated with VA-ECMO plus IABP vs. VA-ECMO alone (OR = 0.31; 95% CI = 0.25-0.40; I2 = 0%) or IABP alone (OR = 0.24; 95% CI = 0.11-0.50; I2 = 0%). A significant difference was observed in weaning from VA-ECMO in patients treated with VA-ECMO plus IABP vs. VA-ECMO alone (OR = 1.91; 95% CI = 1.09-3.33; I2 = 0%). CONCLUSION: In-hospital and 30-days mortality were significantly lower in AMICS patients treated with VA-ECMO plus IABP vs. VA-ECMO alone or IABP alone. VA-ECMO with concomitant IABP could increase the proportion of patients weaned from VA-ECMO, significantly reducing in-hospital mortality, without increasing complications.

6.
J Appl Clin Med Phys ; 22(5): 117-127, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33773008

RESUMO

The performance of three digital detectors was measured at two exposure index (EI) levels in terms of the effect on features at the borderline of detectability. The null hypothesis was that there would be no statistically significant difference in the CNR of marginally visible features of a baseline- (2.2 µGy) and reduced dose (1.4 µGy) images. The experiment used three digital detectors and a phantom composed of an aluminum contrast-recovery plate, with features of varying diameters and hole depths, which was placed between the detector/grid and 5-20 cm Lucite. Exposures were made using a kVp between 55 and 110 corresponding to the Lucite thickness and a mAs producing an EI of approximately 220 or 140. Images were acquired for all detectors, EI values, and all Lucite thicknesses, then scored by a team of physicists and technologists in terms of feature visibility for each feature size. Contrast-to-noise ratio (CNR) was calculated for each feature using an ROI over the feature and a local background annulus. The uncertainty in the CNR was determined by sampling the background at each feature size, finding residuals from an overall background fit, and then calculating a standard deviation in the noise for each size. The marginal feature pair for each feature size bracketed the reader score. The difference between the CNR values of corresponding marginal features in EI-paired images was significant (P < 0.05) for one detector and not significant (P > 0.05) for marginal features of the other two. Based on both reader scoring and CNR measurements of phantoms, patient doses can be lowered by 30% for those two detectors without a statistically significant difference in lesion perceptibility of the marginally visible feature, while for the other detector there was a statistically significant change in marginal feature detectability and dose reduction was not recommended.


Assuntos
Redução da Medicação , Intensificação de Imagem Radiográfica , Humanos , Imagens de Fantasmas , Doses de Radiação
7.
J Psychiatry Neurosci ; 45(1): 15-22, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31368294

RESUMO

Background: White matter network alterations have increasingly been implicated in major depressive disorder, bipolar disorder and schizophrenia. The aim of this study was to identify shared and distinct white matter network alterations among the 3 disorders. Methods: We used analysis of covariance, with age and gender as covariates, to investigate white matter network alterations in 123 patients with schizophrenia, 123 with bipolar disorder, 124 with major depressive disorder and 209 healthy controls. Results: We found significant group differences in global network efficiency (F = 3.386, p = 0.018), nodal efficiency (F = 8.015, p < 0.001 corrected for false discovery rate [FDR]) and nodal degree (F = 5.971, pFDR < 0.001) in the left middle occipital gyrus, as well as nodal efficiency (F = 6.930, pFDR < 0.001) and nodal degree (F = 5.884, pFDR < 0.001) in the left postcentral gyrus. We found no significant alterations in patients with major depressive disorder. Post hoc analyses revealed that compared with healthy controls, patients in the schizophrenia and bipolar disorder groups showed decreased global network efficiency, nodal efficiency and nodal degree in the left middle occipital gyrus. Furthermore, patients in the schizophrenia group showed decreased nodal efficiency and nodal degree in the left postcentral gyrus compared with healthy controls. Limitations: Our findings could have been confounded in part by treatment differences. Conclusion: Our findings implicate graded white matter network alterations across the 3 disorders, enhancing our understanding of shared and distinct pathophysiological mechanisms across diagnoses and providing vital insights into neuroimaging-based methods for diagnosis and research.


Assuntos
Transtorno Bipolar/patologia , Transtorno Depressivo Maior/patologia , Imagem de Tensor de Difusão/métodos , Processamento de Imagem Assistida por Computador/métodos , Rede Nervosa/patologia , Lobo Occipital/patologia , Esquizofrenia/patologia , Córtex Somatossensorial/patologia , Substância Branca/patologia , Adolescente , Adulto , Transtorno Bipolar/diagnóstico por imagem , Conectoma , Transtorno Depressivo Maior/diagnóstico por imagem , Imagem Ecoplanar/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Rede Nervosa/diagnóstico por imagem , Lobo Occipital/diagnóstico por imagem , Esquizofrenia/diagnóstico por imagem , Córtex Somatossensorial/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Adulto Jovem
8.
Neural Plast ; 2020: 8859388, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33381163

RESUMO

Background: Cognitive impairments are documented in schizophrenia (SZ) and bipolar disorder (BD) and may be related to gray matter volumes (GMVs). Thus, this study is aimed at exploring whether the association between cognitive impairments and GMV alterations is similar in patients with SZ and BD and understanding the underlying neurobiological mechanisms. Methods: A total of 137 adult subjects (46 with SZ, 35 with BD, and 56 age-, sex-, and education-matched healthy controls (HC)) completed the MATRICS Consensus Cognitive Battery (MCCB) and structural magnetic resonance imaging scanning. We performed group comparisons of the cognitive impairments, the GMV alterations, and the association between them. Results: Compared with HC, the patients with SZ and BD showed shared deficits in 4 cognitive domains (i.e., processing speed, working memory, problem solving, and social cognition) and the composite. SZ and BD had commonly decreased GMVs, mainly in the insula, superior temporal pole, amygdala, anterior cingulate, and frontal cortices (superior, middle, opercular inferior, and orbital frontal gyrus). No correlation between MCCB scores and GMVs was detected in SZ. However, for BD, working memory was relevant to the right hemisphere (i.e., right insula, amygdala, superior temporal pole, and medial and dorsolateral superior frontal gyrus). Limitations. The major limitations were that not all patients were the first-episode status and no medication. Conclusions: The association was mainly limited to the BD group. Thus, the underlying pathophysiology of the cognitive deficits, in terms of GMV alterations, may be diverse between two disorders.


Assuntos
Transtorno Bipolar/patologia , Encéfalo/patologia , Disfunção Cognitiva/patologia , Substância Cinzenta/patologia , Esquizofrenia/patologia , Adolescente , Adulto , Transtorno Bipolar/diagnóstico por imagem , Transtorno Bipolar/psicologia , Encéfalo/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico por imagem , Disfunção Cognitiva/psicologia , Feminino , Substância Cinzenta/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Tamanho do Órgão/fisiologia , Esquizofrenia/diagnóstico por imagem , Psicologia do Esquizofrênico , Adulto Jovem
9.
J Appl Clin Med Phys ; 21(2): 128-135, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31898865

RESUMO

PURPOSE: The utilization of iterative reconstruction makes it difficult to identify the dose-noise relationship, resulting in empirical design of scan protocols and inconsistent conclusions on dose reduction for consistent image quality. This study was to quantitatively determine the dose and the blending fraction of adaptive statistical iterative reconstruction (ASIR) based on the specified low-contrast detectability (LCD). METHODS: A tissue equivalent abdomen phantom and a GE discovery 750 HD computed tomography (CT) were utilized. The normality of the noise distribution was tested at various spatial scales (2.1-9.8 mm) in the presence of ASIR (10-100%) with a wide range of doses (2.24-38 mGy). The statically defined minimum detectable contrast (MDC) was used as the image quality metric. The parametric model decomposed the MDC into two terms: one with and the other without ASIR, each was related to the dose in the form of power law with factors and indices dependent on spatial scales. The parameters were identified by least-square fitting to the experimental data. By considering the constraint of the blending fraction in the range of [0, 1], the dose and ASIR blending fraction were determined for any specified low-contrast detectability (LCD), quantified by the MDC at the concerned lesion size. RESULTS: It was verified that noise distribution is normal in the presence of ASIR. It was also found that the noises obtained from the subtractions of adjacent slices had an underestimate of 20% as compared to the ground truth noises, regardless of the spatial scale, pitch, or ASIR blending fraction. The least-square fitting for the parametric model resulted in correlation coefficients from 0.905 to 0.996. The root-mean-square errors ranged from 1.27% to 7.15%. CONCLUSION: The parametric model can be used to form a look-up-table for dose and ASIR blending fraction. The dose choices may be substantially limited in some cases depending on the required LCD.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Radiografia Abdominal , Tomografia Computadorizada por Raios X , Algoritmos , Meios de Contraste , Humanos , Análise dos Mínimos Quadrados , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
10.
J Psychiatry Neurosci ; 44(2): 132-141, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30810024

RESUMO

Background: Growing evidence indicates both shared and distinct features of emotional perception in schizophrenia, bipolar disorder and major depressive disorder. In these disorders, alterations in spontaneous low-frequency fluctuations have been reported in the neural system for emotional perception, but the similarities and differences in the amplitude of low-frequency fluctuation (ALFF) across the 3 disorders are unknown. Methods: We compared ALFF and its signal balance in the neural system for emotional perception at 2 frequency bands (slow-5 and slow-4) in 119 participants with schizophrenia, 100 with bipolar disorder, 123 with major depressive disorder and 183 healthy controls. We performed exploratory Pearson partial correlation analyses to determine the relationship between ALFF signal balance and clinical variables. Results: We observed commonalities in ALFF change patterns across the 3 disorders for emotional perception neural substrates, such as increased ALFF in the anterior cerebrum (including subcortical, limbic, paralimbic and heteromodal cortical regions) and decreased ALFF in the posterior visual cortices. Schizophrenia, bipolar disorder and major depressive disorder showed significantly decreased ALFF signal balance in the neural system for emotional perception at both slow-5 and slow-4 frequency bands, with the greatest alterations for schizophrenia, followed by bipolar disorder and major depressive disorder. We found a negative correlation between ALFF signal balance and negative/disorganized symptoms in slow-4 across the 3 disorders. Limitations: The relatively broad age range in our sample and the cross-sectional study design may not account for our findings. Conclusion: The extent of the commonalities we observed further support the concept of core neurobiological disruptions shared among the 3 disorders; ALFF signal balance could be an important neuroimaging marker for the diagnosis and treatment of schizophrenia, bipolar disorder and major depressive disorder.


Assuntos
Transtorno Bipolar/fisiopatologia , Córtex Cerebral/fisiopatologia , Transtorno Depressivo Maior/fisiopatologia , Emoções/fisiologia , Sistema Límbico/fisiopatologia , Neostriado/fisiopatologia , Esquizofrenia/fisiopatologia , Percepção Social , Adolescente , Adulto , Transtorno Bipolar/diagnóstico por imagem , Córtex Cerebral/diagnóstico por imagem , Estudos Transversais , Transtorno Depressivo Maior/diagnóstico por imagem , Feminino , Humanos , Sistema Límbico/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neostriado/diagnóstico por imagem , Esquizofrenia/diagnóstico por imagem , Adulto Jovem
11.
Clin Exp Rheumatol ; 37(1): 156-163, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29846163

RESUMO

OBJECTIVES: Long noncoding RNAs (lncRNAs) are reported to play crucial roles in several physiological and biological processes. However, knowledge of lncRNAs in children with systemic lupus erythematosus (cSLE) remains limited. We investigate lncRNA expression profiling of cSLE and explore the potential function of lncRNAs. METHODS: LncRNA and mRNA microarrays were performed to identify changes in lncRNA and mRNA expression between children with SLE and paired healthy children. Quantitative polymerase chain reaction (qPCR) validated these results. A Gene Ontology (GO) analysis and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway analysis were performed to explore the potential lncRNA function. RESULTS: A comparison between children with SLE and paired healthy children revealed that 1042 lncRNAs and 1162 mRNAs were differentially expressed. By using gene co-expression network analysis, we constructed a complex lncRNA target network consisting of 817 matched lncRNA-mRNA pairs for 309 differentially expressed lncRNAs and 210 differentially expressed mRNAs. The results of further GO and KEGG pathway analyses indicated that lncRNAs were involved mainly in pathways with crucial pathobiological relevance in SLE. CONCLUSIONS: We firstly characterised the expression profiles of lncRNA and mRNA in children with SLE and propose herein their possible roles in the pathogenesis of SLE. These results provide novel insights into the mechanisms of SLE pathogenesis and may serve as diagnostic biomarkers for SLE therapy.


Assuntos
Perfilação da Expressão Gênica/métodos , Lúpus Eritematoso Sistêmico/genética , Análise de Sequência com Séries de Oligonucleotídeos , RNA Longo não Codificante , Estudos de Casos e Controles , Criança , Humanos , RNA Longo não Codificante/genética , RNA Longo não Codificante/metabolismo , RNA Mensageiro
12.
BMC Psychiatry ; 19(1): 108, 2019 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-30953482

RESUMO

BACKGROUND: Based on genome-wide association studies, a single-nucleotide polymorphism in the NRGN gene (rs12807809) is considered associated with schizophrenia (SZ). Moreover, hippocampal dysfunction is associated with rs12807809. In addition, converging evidence suggests that hippocampal dysfunction is involved in SZ pathophysiology. However, the association among rs12807809, hippocampal dysfunction and SZ pathophysiology is unknown. Therefore, this study investigated the association between rs12807809 and hippocampal functional connectivity at rest in SZ. METHODS: In total, 158 participants were studied, including a C-carrier group carrying the non-risk C allele (29 SZ patients and 46 healthy controls) and a TT homozygous group carrying the risk T allele (30 SZ patients and 53 healthy controls). All participants were scanned using resting-state functional magnetic resonance imaging. Hippocampal functional connectivity was computed and compared among the 4 groups. RESULTS: Significant main effects of diagnosis were observed in the functional connectivity between the hippocampus and bilateral fusiform gyrus, bilateral lingual gyrus, left inferior temporal gyrus, left caudate nucleus, bilateral thalamus and bilateral anterior cingulate gyri. In contrast, no significant main effect of genotype was found. In addition, a significant genotype by diagnosis interaction in the functional connectivity between the hippocampus and left anterior cingulate gyrus, as well as bilateral middle cingulate gyri, was observed, with TT homozygotes with SZ showing less functional connectivity than C-carriers with SZ and healthy control TT homozygotes. CONCLUSIONS: These findings are the first to suggest an association between rs12807809 and abnormal Papez circuit function in patients with SZ. This study also implicates NRGN variation and abnormal Papez circuit function in SZ pathophysiology.


Assuntos
Genótipo , Neurogranina/genética , Polimorfismo de Nucleotídeo Único , Esquizofrenia/genética , Esquizofrenia/patologia , Adulto , Alelos , Feminino , Estudo de Associação Genômica Ampla , Giro do Cíngulo/patologia , Hipocampo/patologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Lobo Temporal/fisiopatologia , Tálamo/patologia
13.
BMC Psychiatry ; 19(1): 30, 2019 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-30654778

RESUMO

BACKGROUND: Cognitive impairments are prominent in schizophrenia (SZ). Imaging studies have demonstrated that functional changes of several areas of the brain exist in SZ patients. The relationships between these two indexes are largely unexplored in SZ. The MATRICS Consensus Cognitive Battery (MCCB) was used to measure cognitive impairment in multi-dimensional cognitive fields of SZ patients. This study was conducted to explore the relationship between cognitive functional impairment and the amplitude of low-frequency fluctuation (ALFF) in SZ patients. METHOD: A total of 104 participants (44 SZ patients and 60 age- and gender-matched healthy controls (HC)) were recruited for this study. The MCCB was used to assess cognitive function of the participants, while brain activity was assessed using the ALFF. The relationship between the MCCB and the ALFF was investigated by using a correlation analysis. RESULTS: There were significant differences between SZ patients and HC in MCCB total and domain scores as well as in ALFF results. The reduction of ALFF in the bilateral postcentral gyri and paracentral lobule in SZ patients has a negative correlation with the MCCB sub-test of symbol coding. CONCLUSION: These findings suggest that the reduction of ALFF in bilateral postcentral gyri and paracentral lobule may be related to cognitive impairment in SZ patients.


Assuntos
Encéfalo/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico por imagem , Disfunção Cognitiva/psicologia , Imageamento por Ressonância Magnética/métodos , Esquizofrenia/diagnóstico por imagem , Psicologia do Esquizofrênico , Adolescente , Adulto , Encéfalo/fisiopatologia , Disfunção Cognitiva/fisiopatologia , Correlação de Dados , Feminino , Humanos , Masculino , Escalas de Graduação Psiquiátrica , Esquizofrenia/fisiopatologia , Adulto Jovem
14.
BMC Psychiatry ; 18(1): 177, 2018 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-29871591

RESUMO

BACKGROUND: Bipolar disorder (BD) is a serious mental illness. Several studies have shown that brain structure and function changes and the development of BD are associated with age and sex differences. Therefore, we hypothesized that the functional and structural neural circuitry of BD patients would differ according to age. The amygdala and prefrontal cortex (PFC) are play a key role in the emotional and cognitive processing of patients with BD. In this study, we used magnetic resonance imaging (MRI) to examine the structural and functional connectivity within amygdala-PFC neural circuitry in women with BD at different ages. METHODS: Forty-nine female patients with BD who were aged 13-25 years and 60 age-matched healthy control (HC) individuals, as well as 43 female patients with BD who were aged 26-45 years and 60 age-matched HC individuals underwent resting-state functional MRI (rs-fMRI) and diffusion tensor imaging to examine the structural and functional connectivity within the amygdala-PFC neural circuitry. RESULTS: We found abnormalities in the amygdala-PFC functional connectivity in patients aged 13-25 years and significantly different fractional anisotropy (FA) values in patients aged 26-45 compared with the age-matched HCs. The significance of these findings was indicated by corrected p values of less than 0.05 (uncorrected p values less than 0.001). CONCLUSIONS: The findings in this cross-sectional study suggested that abnormalities in the functional connectivity of the amygdala-PFC neural circuitry are related to the pathophysiology of BD in women aged 13-25 years, while changes in the structural integrity of this neural circuitry are associated with the pathophysiology of BD in women aged 26-45 years. Therefore, functional and structural brain alterations may occur at different ages in female patients with BD.


Assuntos
Tonsila do Cerebelo , Transtorno Bipolar , Conectoma/métodos , Córtex Pré-Frontal , Adolescente , Adulto , Tonsila do Cerebelo/diagnóstico por imagem , Tonsila do Cerebelo/fisiopatologia , Transtorno Bipolar/patologia , Transtorno Bipolar/fisiopatologia , Transtorno Bipolar/psicologia , Estudos de Casos e Controles , Estudos Transversais , Imagem de Tensor de Difusão/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Córtex Pré-Frontal/diagnóstico por imagem , Córtex Pré-Frontal/fisiopatologia
16.
J Appl Clin Med Phys ; 17(6): 343-355, 2016 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-27929507

RESUMO

Some digital radiography (DR) detectors and software allow for remote download of exam statistics, including image reject status, body part, projection, and exposure index (EI). The ability to have automated data collection from multiple DR units is conducive to a quality control (QC) program monitoring institutional radiographic exposures. We have implemented such a QC program with the goal to identify outliers in machine radiation output and opportunities for improvement in radiation dose levels. We studied the QC records of four digital detectors in greater detail on a monthly basis for one year. Although individual patient entrance skin exposure varied, the radiation dose levels to the detectors were made to be consistent via phototimer recalibration. The exposure data stored on each digital detector were periodically downloaded in a spreadsheet format for analysis. EI median and stan-dard deviation were calculated for each protocol (by body part) and EI histograms were created for torso protocols. When histograms of EI values for different units were compared, we observed differences up to 400 in average EI (representing 60% difference in radiation levels to the detector) between units nominally cali-brated to the same EI. We identified distinct components of the EI distributions, which in some cases, had mean EI values 300 apart. Peaks were observed at the current calibrated EI, a previously calibrated EI, and an EI representing computed radiography (CR) techniques. Our findings in this ongoing project have allowed us to make useful interventions, from emphasizing the use of phototimers instead of institutional memory of manual techniques to improvements in our phototimer calibration. We believe that this QC program can be implemented at other sites and can reveal problems with radiation levels in the aggregate that are difficult to identify on a case-by-case basis.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde , Exposição à Radiação/análise , Proteção Radiológica/normas , Intensificação de Imagem Radiográfica/instrumentação , Radiografia/métodos , Radiografia/normas , Humanos , Doses de Radiação , Radiografia Abdominal/normas , Radiografia Torácica/normas , Raios X
17.
BMC Nephrol ; 16: 142, 2015 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-26283194

RESUMO

BACKGROUND: Burn patients with AKI have a higher mortality, rapid diagnosis and early treatment of AKI are necessary. Recent studies have demonstrated that urinary KIM-1 and IL-18 are potential biomarkers of early-stage AKI, however, changes in urinary KIM-1 and IL-18 levels are unclear in patients with burns. The aim of our study was to determine whether combined KIM-1 and IL-18 are more sensitive than traditional markers in detecting kidney injury in patients with burns. METHODS: Ninety-five burn patients hospitalized at the Burns and Plastic Surgery Center of our hospital from April 2013 to September 2013 were enrolled into this prospective study and divided into mild- (n = 37), moderate- (n = 30) and severe-burn groups (n = 28) by burn injury surface area. In the moderate- and severe-burn groups, patients were subcategorized to either the acute kidney injury (AKI) group, in which serum creatinine (Scr) increased to ≥ 26.5 µmol/L within 48 h, or the non-AKI group. Fifteen healthy subjects were selected as a control group. Blood specimens were collected to determine blood urea nitrogen (BUN), Scr, and other biochemical indicators. Urine samples collected at admission and 48 h after admission were analyzed for KIM-1 and IL-18. Correlations among urinary KIM-1 and IL-18, burn degree, and clinical biochemical indicators were investigated. RESULTS: AKI occurred in 11.2 % of burn patients (none in the mild-burn group). AKI developed 48 h after admission in 10.0 % of the moderate- and 28.6 % of the severe-burn groups. Urinary KIM-1 concentration in the moderate- and severe-burn groups was significantly higher than that in the control group; urinary IL-18 concentrations did not differ significantly among the burn and control groups. The AKI group had significantly higher concentrations of urinary KIM-1 and IL-18 than the non-AKI group, both at admission (p = 0.001 and p < 0.001, respectively) and 48 h later (p = 0.001 and p < 0.001, respectively). Both urinary KIM-1 and IL-18 increased before Scr. Receiver operating-curve (ROC) analysis demonstrated that KIM-1 combined with IL-18 predicted AKI with 72.7 % sensitivity and 92.8 % specificity. The area under the ROC curve was 0.904. CONCLUSIONS: Our results suggest that urinary KIM-1 and IL-18 may be used as early, sensitive indicators of AKI in patients with burns of varying degrees and provide clinical clues that can be used in early prevention of AKI.


Assuntos
Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/urina , Queimaduras/urina , Interleucina-18/urina , Glicoproteínas de Membrana/urina , Injúria Renal Aguda/etiologia , Adulto , Área Sob a Curva , Biomarcadores/urina , Nitrogênio da Ureia Sanguínea , Superfície Corporal , Queimaduras/classificação , Queimaduras/complicações , Estudos de Casos e Controles , Creatinina/sangue , Feminino , Receptor Celular 1 do Vírus da Hepatite A , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Receptores Virais , Índices de Gravidade do Trauma , Adulto Jovem
18.
J Xray Sci Technol ; 22(3): 377-94, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24865213

RESUMO

To quantify the trade-offs of dose and image quality among pre-loaded automatic exposure control (AEC) options in digital mammography, two AEC tables from the Hologic Selenia digital mammography system were compared: the default AEC "table 0" and AEC "table 1". Realistically-shaped phantoms consisting of tissue-equivalent material of various thicknesses (4.5 cm-7 cm) were imaged to obtain a figure of merit (FOM), the squared contrast-to-noise ratio per mean glandular dose. To relate the results to pathological findings and to evaluate the overall performance, the measured contrast-to-noise ratios were applied to simulated lesions on the anthropomorphic breast phantom images, producing various lesion configurations which were blindly scored. It was found that the AEC table 1 improves the low contrast FOM by 11% to 20% for the breast thicknesses of 4.5-6 cm. However, for the 7 cm thick breast, the AEC table 1 decreases the low contrast FOM by 17%. For microcalcifications, the AEC table 1 improves the FOM slightly for the breast thicknesses of 4.5--6 cm and decreases it by 18% at a thickness of 7 cm. The lesion simulation showed enhanced contrast due to the AEC table 1 for the breast thicknesses of 5 cm, 6 cm, and 7 cm, but the enhancement gradually reduces as the thickness increases. The lesion reading showed that the microcalcification detection was scored significantly higher from the AEC table 1 for the thicknesses 5 cm, 6 cm, and 7 cm. The corresponding improvement of mass detection scores was also observed but not consistently significant over the thickness range.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Mamografia/métodos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Imagens de Fantasmas , Ultrassonografia
19.
J Am Coll Radiol ; 21(7): 1058-1066, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38286300

RESUMO

PURPOSE: Challenges from administrative support, scanners' heterogeneity, patient size variation, and protocol mapping hinder CT protocol and dose management. We present a holistic approach to overcome these challenges. METHODS: A dose tracking software was selected with two key requirements: intelligent protocol mapping and customizable dose threshold settings according to the patient size. A multifaceted workflow was carefully implemented. It included patient size-dependent dose thresholds for e-mail alerts, a base protocol archive on a website with a unified format using an in-house developed reformat software upon protocol export, prompt dose alert follow-up, and well-controlled protocol changes. The thresholds were iteratively updated following protocol changes or review of dose statistics. The program outcome was evaluated using 11 protocols from January 2020 to May 2023 (N = 148,678) in comparison to ACR's achievable dose (AD) and dose reference levels (DRLs). RESULTS: The 75th percentile dose data were lower than the ACR's DRL on average, ranging from -4.9% to -36%. The median doses were in a range of -23% to 19% on average in comparison with the ACR's AD. The median value from pulmonary embolism scans initially showed 36% higher than the AD but was gradually reduced to nearly 3% lower than the AD. The percentage of unjustified alerted cases decreased from 80% in first half year of 2020 to 17% in the first 5 months of 2023. CONCLUSIONS: The results showed that our holistic approach to protocol and dose management has been effective. The impact to practice has been prompt and sustainable.


Assuntos
Doses de Radiação , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Software , Protocolos Clínicos , Proteção Radiológica/métodos , Fluxo de Trabalho
20.
J Affect Disord ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38972643

RESUMO

OBJECTIVE: Increasing evidence has shown that the microbiota-gut-brain axis (MGB) is involved in the mechanism of major depressive disorder (MDD). However, the relationship between the gut microbiome and brain function in MDD patients has not been determined. Here, we intend to identify specific changes in the gut microbiome and brain function in first-episode, drug-naïve MDD patients and then explore the associations between the two omics to elucidate how the MGB axis plays a role in MDD development. METHODS: We recruited 38 first-episode, drug-naïve MDD patients and 37 healthy controls (HC). The composition of the fecal microbiome and neural spontaneous activity alterations were examined using 16S rRNA gene amplicon sequencing analysis and regional homogeneity (ReHo). Spearman correlation analyses were conducted to assess the associations between the gut microbiome and brain function. RESULTS: Compared with HC, MDD patients exhibited distinct alterations in the gut microbiota and elevated ReHo in the frontal regions. In the MDD group, a positive relationship was noted between the relative abundance of Blautia and the HAMD-17 and HAMA scores, as well as between the relative abundance of Oxalobacteraceae and the HAMD-17 score. The relative abundances of Porphyromonadaceae and Parabacteroides were negatively correlated with the ReHo values of frontal regions. LIMITATIONS: Our study utilized a cross-sectional design, and the number of subjects was relatively small. CONCLUSION: We found that some specific gut microbiomes were associated with frontal function, and others were associated with clinical symptoms in MDD patients, which may support the role of the MGB axis underlying MDD.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA