1.
Magn Reson Med ; 89(1): 205-216, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36129110

RESUMO

PURPOSE: The goal of this study was to apply a fast data-driven optimization algorithm, called bias-accelerated subset selection, for MR brain T1ρ mapping to generate optimized sampling patterns (SPs) for compressed sensing reconstruction of brain 3D-T1ρ MRI. METHODS: Five healthy volunteers were recruited, and fully sampled Cartesian 3D-T1ρ MRIs were obtained. Variable density (VD) and Poisson disc (PD) undersampling was used as the input to SP optimization process. The reconstruction used 3 compressed sensing methods: spatiotemporal finite differences, low-rank plus sparse with spatial finite differences, and low rank. The performance of images and T1ρ maps using PD-SP and VD-SP and their optimized sampling patterns (PD-OSP and VD-OSP) were compared to the fully sampled reference using normalized root mean square error (NRMSE). RESULTS: The VD-OSP with spatiotemporal finite differences reconstruction (NRMSE = 0.078) and the PD-OSP with spatiotemporal finite differences reconstruction (NRMSE = 0.079) at the highest acceleration factors (AF = 30) showed the largest improvement compared to the respective nonoptimized SPs (VD NRMSE = 0.087 and PD NRMSE = 0.149). Prospective undersampling was tested at AF = 4, with VD-OSP NRMSE = 0.057 versus PD-OSP NRMSE = 0.060, with optimized sampling performing better that input PD or VD sampling. For brain T1ρ mapping, the VD-OSP with low rank reconstruction for AFs <10 and VD-OSP with spatiotemporal finite differences for AFs >10 perform better. CONCLUSIONS: The study demonstrated that the appropriate use of data-driven optimized sampling and suitable compressed sensing reconstruction technique can be employed to potentially accelerate 3D T1ρ mapping for brain imaging applications.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Humanos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Aceleração , Processamento de Imagem Assistida por Computador/métodos
2.
Magn Reson Med ; 90(4): 1465-1483, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37288538

RESUMO

PURPOSE: To optimize the choice of the flip angles of magnetization-prepared gradient-echo sequences for improved accuracy, precision, and speed of 3D-T1ρ mapping. METHODS: We propose a new optimization approach for finding variable flip-angle values that improve magnetization-prepared gradient-echo sequences used for 3D-T1ρ mapping. This new approach can improve the accuracy and SNR, while reducing filtering effects. We demonstrate the concept in the three different versions of the magnetization-prepared gradient-echo sequences that are typically used for 3D-T1ρ mapping and evaluate their performance in model agarose phantoms (n = 4) and healthy volunteers (n = 5) for knee joint imaging. We also tested the optimization with sequence parameters targeting faster acquisitions. RESULTS: Our results show that optimized variable flip angle can improve the accuracy and the precision of the sequences, seen as a reduction of the mean of normalized absolute difference from about 5%-6% to 3%-4% in model phantoms and from 15%-16% to 11%-13% in the knee joint, and improving SNR from about 12-28 to 22-32 in agarose phantoms and about 7-14 to 13-17 in healthy volunteers. The optimization can also compensate for the loss in quality caused by making the sequence faster. This results in sequence configurations that acquire more data per unit of time with SNR and mean of normalized absolute difference measurements close to its slower versions. CONCLUSION: The optimization of the variable flip angle can be used to increase accuracy and precision, and to improve the speed of the typical imaging sequences used for quantitative 3D-T1ρ mapping of the knee joint.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Sefarose , Algoritmos , Aumento da Imagem/métodos , Imagens de Fantasmas
3.
J Magn Reson Imaging ; 57(6): 1805-1812, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36190187

RESUMO

BACKGROUND: Magnetic resonance fingerprinting (MRF) techniques have been recently described for simultaneous multiparameter cartilage mapping of the knee although investigation of their ability to detect early cartilage degeneration remains limited. PURPOSE: To investigate age-dependent changes in knee cartilage T1 , T2 , and T1p relaxation times measured using a three-dimensional (3D) MRF sequence in healthy volunteers. STUDY TYPE: Prospective. SUBJECTS: The study group consisted of 24 healthy asymptomatic human volunteers (15 males with mean age 34.9 ± 14.4 years and 9 females with mean age 44.5 ± 13.1 years). FIELD STRENGTH/SEQUENCE: A 3.0 T gradient-echo-based 3D-MRF sequence was used to simultaneously create proton density-weighted images and T1 , T2 , and T1p maps of knee cartilage. ASSESSMENT: Mean global cartilage and regional cartilage (lateral femur, lateral tibia, medial femur, medial tibia, and patella) T1 , T2 , and T1ρ relaxation times of the knee were measured. STATISTICAL TESTS: Kruskal-Wallis tests were used to compared cartilage T1 , T2 , and T1ρ relaxation times between different age groups, while Spearman correlation coefficients was used to determine the association between age and cartilage T1 , T2 , and T1ρ relaxation times. The value of P < 0.05 was considered statistically significant. RESULTS: Higher age groups showed higher global and regional cartilage T1 , T2 , and T1ρ . There was a significant difference between age groups in global cartilage T2 and T1ρ but no significant difference (P = 0.13) in global cartilage T1. Significant difference was also present between age groups in cartilage T2 and T1ρ for medial femur cartilage and medial tibia cartilage. There were significant moderate correlations between age and T2 and T1ρ for global cartilage (R2  = 0.63-0.64), medial femur cartilage (R2  = 0.50-0.56), and medial tibia cartilage (R2  = 0.54-0.66). CONCLUSION: Cartilage T2 and T1p relaxation times simultaneously measured using a 3D-MRF sequence in healthy volunteers showed age-dependent changes in knee cartilage, primarily within the medial compartment.


Assuntos
Cartilagem Articular , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Estudos Prospectivos , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/patologia , Joelho , Imageamento por Ressonância Magnética/métodos
4.
J Magn Reson Imaging ; 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37877751

RESUMO

BACKGROUND: There is limited understanding of differences in the composition and structure of ligaments between healthy males and females, and individuals of different ages. Females present higher risk for ligament injuries than males and there are conflicting reports on its cause. This study looks into T1ρ parameters for an explanation as it relates to proteoglycan, collagen, and water content in these tissues. PURPOSE: To investigate gender-related and age-related differences in T1ρ parameters in knee joint ligaments in healthy volunteers using a T1ρ -prepared zero echo-time (ZTE)-based pointwise-encoding time-reduction with radial acquisition (T1ρ -PETRA) sequence. STUDY TYPE: Prospective. POPULATION: The study group consisted of 22 healthy subjects (11 females, ages: 41 ± 18 years, and 11 males, ages: 41 ± 14 years) with no known inflammation, trauma, or pain in the knee joint. FIELD STRENGTH/SEQUENCE: A T1ρ -prepared 3D-PETRA sequence was used to acquire fat-suppressed images with varying spin-lock lengths (TSLs) of the knee joint at 3T. ASSESSMENT: Monoexponential, biexponential, and stretched-exponential 3D-PETRA-T1ρ parameters were measured in the anterior cruciate ligament (ACL), posterior cruciate ligament (PCL), and patellar tendon (PT) by manually drawing ROIs over the entirety of the tissues. STATISTICAL TESTS: Mann-Whitney U-tests were used to compare 3D-PETRA-T1ρ parameters in the ACL, PCL, and PT between males and females. Spearman correlation coefficients were used to determine the association between age and T1ρ parameters. Statistical significance was defined as P < 0.05. RESULTS: Significant correlations with age were found the three ligaments with most of the measured T1ρ parameters (rs = 0.28-0.74) with the exception of the short fraction in the PCL (P = 0.18), and the short relaxation time in the ACL (P = 0.58) and in the PCL (P = 0.14). DATA CONCLUSION: 3D-PETRA-T1ρ can detect age-related differences in monoexponential, biexponential, and stretched-exponential T1ρ parameters in three ligaments of healthy volunteers, which are thought to be related to changes in tissue composition and structure during the aging process. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

5.
J Magn Reson Imaging ; 2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37885320

RESUMO

BACKGROUND: Three-dimensional MR fingerprinting (3D-MRF) techniques have been recently described for simultaneous multiparametric mapping of knee cartilage. However, investigation of repeatability remains limited. PURPOSE: To assess the intra-day and inter-day repeatabilities of knee cartilage T1 , T2 , and T1ρ maps using a 3D-MRF sequence for simultaneous measurement. STUDY TYPE: Prospective. SUBJECTS: Fourteen healthy subjects (35.4 ± 9.3 years, eight males), scanned on Day 1 and Day 7. FIELD STRENGTH/SEQUENCE: 3 T/3D-MRF, T1 , T2 , and T1ρ maps. ASSESSMENT: The acquisition of 3D-MRF cartilage (simultaneous acquisition of T1 , T2 , and T1ρ maps) were acquired using a dictionary pattern-matching approach. Conventional cartilage T1 , T2 , and T1ρ maps were acquired using variable flip angles and a modified 3D-Turbo-Flash sequence with different echo and spin-lock times, respectively, and were fitted using mono-exponential models. Each sequence was acquired on Day 1 and Day 7 with two scans on each day. STATISTICAL TESTS: The mean and SD for cartilage T1 , T2 , and T1ρ were calculated in five manually segmented regions of interest (ROIs), including lateral femur, lateral tibia, medial femur, medial tibia, and patella cartilages. Intra-subject and inter-subject repeatabilities were assessed using coefficient of variation (CV) and intra-class correlation coefficient (ICC), respectively, on the same day and among different days. Regression and Bland-Altman analysis were performed to compare maps between the conventional and 3D-MRF sequences. RESULTS: The CV in all ROIs was lower than 7.4%, 8.4%, and 7.5% and the ICC was higher than 0.56, 0.51, and 0.52 for cartilage T1 , T2 , and T1ρ , respectively. The MRF results had a good agreement with the conventional methods with a linear regression slope >0.61 and R2 > 0.59. CONCLUSION: The 3D-MRF sequence had high intra-subject and inter-subject repeatabilities for simultaneously measuring knee cartilage T1 , T2 , and T1ρ with good agreement with conventional sequences. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.

6.
J Magn Reson Imaging ; 58(1): 44-60, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37010113

RESUMO

Osteoarthritis (OA) is a widely occurring degenerative joint disease that is severely debilitating and causes significant socioeconomic burdens to society. Magnetic resonance imaging (MRI) is the preferred imaging modality for the morphological evaluation of cartilage due to its excellent soft tissue contrast and high spatial resolution. However, its utilization typically involves subjective qualitative assessment of cartilage. Compositional MRI, which refers to the quantitative characterization of cartilage using a variety of MRI methods, can provide important information regarding underlying compositional and ultrastructural changes that occur during early OA. Cartilage compositional MRI could serve as early imaging biomarkers for the objective evaluation of cartilage and help drive diagnostics, disease characterization, and response to novel therapies. This review will summarize current and ongoing state-of-the-art cartilage compositional MRI techniques and highlight emerging methods for cartilage compositional MRI including MR fingerprinting, compressed sensing, multiexponential relaxometry, improved and robust radio-frequency pulse sequences, and deep learning-based acquisition, reconstruction, and segmentation. The review will also briefly discuss the current challenges and future directions for adopting these emerging cartilage compositional MRI techniques for use in clinical practice and translational OA research studies. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Assuntos
Cartilagem Articular , Sistema Musculoesquelético , Osteoartrite do Joelho , Humanos , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Imageamento por Ressonância Magnética/métodos , Estudos Longitudinais , Osteoartrite do Joelho/patologia
7.
Magn Reson Med ; 87(3): 1418-1434, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34738252

RESUMO

PURPOSE: To compare different optimization approaches for choosing the spin-lock times (TSLs), in spin-lattice relaxation time in the rotating frame (T1ρ ) mapping. METHODS: Optimization criteria for TSLs based on Cramér-Rao lower bounds (CRLB) are compared with matched sampling-fitting (MSF) approaches for T1ρ mapping on synthetic data, model phantoms, and knee cartilage. The MSF approaches are optimized using robust methods for noisy cost functions. The MSF approaches assume that optimal TSLs depend on the chosen fitting method. An iterative non-linear least squares (NLS) and artificial neural networks (ANN) are tested as two possible T1ρ fitting methods for MSF approaches. RESULTS: All optimized criteria were better than non-optimized ones. However, we observe that a modified CRLB and an MSF based on the mean of the normalized absolute error (MNAE) were more robust optimization approaches, performing well in all tested cases. The optimized TSLs obtained the best performance with synthetic data (3.5-8.0% error), model phantoms (1.5-2.8% error), and healthy volunteers (7.7-21.1% error), showing stable and improved quality results, comparing to non-optimized approaches (4.2-13.3% error on synthetic data, 2.1-6.2% error on model phantoms, 9.8-27.8% error on healthy volunteers). CONCLUSION: A modified CRLB and the MSF based on MNAE are robust optimization approaches for choosing TSLs in T1ρ mapping. All optimized criteria allowed good results even using rapid scans with two TSLs when a complex-valued fitting is done with iterative NLS or ANN.


Assuntos
Cartilagem Articular , Imageamento por Ressonância Magnética , Cartilagem Articular/diagnóstico por imagem , Humanos , Joelho , Articulação do Joelho/diagnóstico por imagem , Imagens de Fantasmas
8.
NMR Biomed ; 35(12): e4800, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35815660

RESUMO

Quantitative MRI can detect early biochemical changes in cartilage; however, the conventional techniques only measure one parameter (e.g., T1 , T2 , and T1ρ ) at a time while also being comparatively slow. We implemented a 3D magnetic resonance fingerprinting (3D-MRF) technique for simultaneous, volumetric mapping of T1 , T2 , and T1ρ in knee articular cartilage in under 9 min. It is evaluated on 11 healthy volunteers (mean age: 53 ± 9 years), five mild knee osteoarthritis (OA) patients (Kellgren-Lawrence (KL) score: 2, mean age: 60 ± 4 years), and the National Institute of Standards and Technology (NIST)/International Society for Magnetic Resonance in Medicine (ISMRM) system phantom. Proton density image, and T1 , T2, T1ρ relaxation times, and B1 + were estimated in the NIST/ISMRM system phantom as well as in the human knee medial and lateral femur, medial and lateral tibia, and patellar cartilage. The repeatability and reproducibility of the proposed technique were assessed in the phantom using analysis of the Bland-Altman plots. The intrasubject repeatability was assessed with the coefficient of variation (CV) and root mean square CV (rmsCV). The Mann-Whitney U test was used to assess the difference between healthy subjects and mild knee OA patients. The Bland-Altman plots in the NIST/ISMRM phantom demonstrated an average difference of 0.001% ± 015%, 1.2% ± 7.1%, and 0.47% ± 3% between two scans from the same 3-T scanner (repeatability), and 0.002% ± 015%, 0.62% ± 10.5%, and 0.97% ± 14% between the scans acquired on two different 3-T scanners (reproducibility) for T1 , T2 , and T1ρ , respectively. The in vivo knee study showed excellent repeatability with rmsCV less than 1%, 2%, and 1% for T1 , T2 , and T1ρ , respectively. T1ρ relaxation time in the mild knee OA patients was significantly higher (p < 0.05) than in healthy subjects. The proposed 3D-MRF sequence is fast, reproducible, robust to B1 + inhomogeneity, and can simultaneously measure the T1 , T2 , T1ρ , and B1 + volumetric maps of the knee joint in a single scan within a clinically feasible scan time.


Assuntos
Cartilagem Articular , Osteoartrite do Joelho , Humanos , Adulto , Pessoa de Meia-Idade , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Articulação do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/patologia , Espectroscopia de Ressonância Magnética
9.
NMR Biomed ; 35(5): e4651, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34825750

RESUMO

Quantitative MRI can detect early biochemical changes in cartilage, but its bilateral use in clinical routines is challenging. The aim of this prospective study was to demonstrate the feasibility of magnetic resonance fingerprinting for bilateral simultaneous T1 , T2 , and T1ρ mapping of the hip joint. The study population consisted of six healthy volunteers with no known trauma or pain in the hip. Monoexponential T1 , T2 , and T1ρ relaxation components were assessed in femoral lateral, superolateral, and superomedial, and inferior, as well as acetabular, superolateral, and superomedial subregions in left and right hip cartilage. Aligned ranked nonparametric factorial analysis was used to assess the side's impact on the subregions. Kruskal-Wallis and Wilcoxon tests were used to compare subregions, and coefficient of variation to assess repeatability. Global averages of T1 (676.0 ± 45.4 and 687.6 ± 44.5 ms), T2 (22.5 ± 2.6 and 22.1 ± 2.5 ms), and T1ρ (38.2 ± 5.5 and 38.2 ± 5.5 ms) were measured in the left and right hip, and articular cartilage, respectively. The Kruskal-Wallis test showed a significant difference between different subregions' relaxation times regardless of the hip side (p < 0.001 for T1 , p = 0.012 for T2 , and p < 0.001 for T1ρ ). The Wilcoxon test showed that T1 of femoral layers was significantly (p < 0.003) higher than that for acetabular cartilage. The experiments showed excellent repeatability with CVrms of 1%, 2%, and 4% for T1 , T2 , and T1ρ, respectively. It was concluded that bilateral T1 , T2 , and T1ρ relaxation times, as well as B1+ maps, can be acquired simultaneously from hip joints using the proposed MRF sequence.


Assuntos
Cartilagem Articular , Imageamento por Ressonância Magnética , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Humanos , Espectroscopia de Ressonância Magnética , Estudos Prospectivos
10.
J Magn Reson Imaging ; 54(2): 486-496, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33713520

RESUMO

BACKGROUND: Noninvasive measurement of internal dynamic strain can be potentially useful to characterize spine intervertebral disc (IVD) in the setting of injury or degenerative disease. PURPOSE: To develop and demonstrate a noninvasive technique to quantify three-dimensional (3D) internal dynamic strains in the IVD using a combination of static mechanical loading of the IVD using a magnetic resonance imaging (MRI)-compatible ergometer. STUDY TYPE: Prospective. SUBJECTS: Silicone gel phantom studies were conducted to assess strain variation with load and repeatability. Mechanical testing was done on the phantoms to confirm MR results. Eight healthy human volunteers (four men and four woman, age = 29 ± 5 years) underwent MRI using a rest, static loading, and recovery paradigm. Repeatability tests were conducted in three subjects. FIELD STRENGTH/SEQUENCE: MRI (3 T) with 3D continuous golden-angle radial sparse parallel (GRASP) and compressed sensing (CS) reconstruction. ASSESSMENT: CS reconstruction of the images, motion deformation, and Lagrangian strain maps were calculated for five IVD segments from L1/L2 to L5/S1. STATISTICAL TESTS: Ranges of displacement and strain in each subject and the resulting mean and standard deviation were calculated. Student t-tests were used to calculate changes in strain from loading to recovery. The correlation coefficient (CC) in the repeatability study was calculated. RESULTS: The most compressive strain experienced by the IVD segments under loaded conditions was in the L4/L5 segment (-7.5 ± 2.9%). The change in minimum strain from load to recovery was the most for the L4/L5 segment (-7.5% to -5.0%, P = 0.026) and the least for the L1/L2 segment (-4.4% to -3.9%, P = 0.51). In vivo repeatability in three subjects shows strong correlation between scans in subjects done 6 months apart, with CCs equal to 0.86, 0.94, and 0.94 along principal directions. DATA CONCLUSION: This study shows the feasibility of using static mechanical loading with continuous GRASP-MRI acquisition with CS reconstruction to measure 3D internal dynamic strains in the spine IVD. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Degeneração do Disco Intervertebral , Disco Intervertebral , Adulto , Feminino , Humanos , Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Região Lombossacral , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Adulto Jovem
11.
J Magn Reson Imaging ; 53(4): 1130-1139, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33190362

RESUMO

BACKGROUND: 3D-T1ρ mapping is useful to quantify various neurologic disorders, but data are currently time-consuming to acquire. PURPOSE: To compare the performance of five compressed sensing (CS) algorithms-spatiotemporal finite differences (STFD), exponential dictionary (EXP), 3D-wavelet transform (WAV), low-rank (LOW) and low-rank plus sparse model with spatial finite differences (L + S SFD)-for 3D-T1ρ mapping of the human brain with acceleration factors (AFs) of 2, 5, and 10. STUDY TYPE: Retrospective. SUBJECTS: Eight healthy volunteers underwent T1ρ imaging of the whole brain. FIELD STRENGTH/SEQUENCE: The sequence was fully sampled 3D Cartesian ultrafast gradient echo sequence with a customized T1ρ preparation module on a clinical 3T scanner. ASSESSMENT: The fully sampled data was undersampled by factors of 2, 5, and 10 and reconstructed with the five CS algorithms. Image reconstruction quality was evaluated and compared to the SENSE reconstruction of the fully sampled data (reference) and T1ρ estimation errors were assessed as a function of AF. STATISTICAL TESTS: Normalized root mean squared errors (nRMSE) and median normalized absolute deviation (MNAD) errors were calculated to compare image reconstruction errors and T1ρ estimation errors, respectively. Linear regression plots, Bland-Altman plots, and Pearson correlation coefficients (CC) are shown. RESULTS: For image reconstruction quality, at AF = 2, EXP transforms had the lowest mRMSE (1.56%). At higher AF values, STFD performed better, with the smallest errors (3.16% at AF = 5, 4.32% at AF = 10). For whole-brain quantitative T1ρ mapping, at AF = 2, EXP performed best (MNAD error = 1.62%). At higher AF values (AF = 5, 10), the STFD technique had the least errors (2.96% at AF = 5, 4.24% at AF = 10) and the smallest variance from the reference T1ρ estimates. DATA CONCLUSION: This study demonstrates the use of different CS algorithms that may be useful in reducing the scan time required to perform volumetric T1ρ mapping of the brain. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 1.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Estudos Retrospectivos
12.
Magn Reson Med ; 83(4): 1291-1309, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31626381

RESUMO

PURPOSE: To use golden-angle radial sampling and compressed sensing (CS) for accelerating mono- and biexponential 3D spin-lattice relaxation time in the rotating frame (T1ρ ) mapping of knee cartilage. METHODS: Golden-angle radial stack-of-stars and Cartesian 3D-T1ρ -weighted knee cartilage datasets (n = 12) were retrospectively undersampled by acceleration factors (AFs) 2-10. CS-based reconstruction using 8 different sparsifying transforms were compared for mono- and biexponential T1ρ -mapping of knee cartilage, including spatio-temporal finite differences, wavelets, dictionary from principal component analysis, and exponential decay models, and also low rank and low rank plus sparse models (L+S). Complex-valued fitting was used and Marchenko-Pastur principal component analysis filtering also tested. RESULTS: Most CS methods performed well for an AF of 2, with relative median normalized absolute deviation below 10% for monoexponential and biexponential mapping. For monoexponential mapping, radial sampling obtained a median normalized absolute deviation below 10% up to AF of 10, while Cartesian obtained this level of error only up to AF of 4. Radial sampling was also better with biexponential T1ρ mapping, with median normalized absolute deviation below 10% up to AF of 6. CONCLUSION: Golden-angle radial acquisitions combined with CS outperformed Cartesian acquisitions for 3D-T1ρ mapping of knee cartilage, being it is a good alternative to Cartesian sampling for reducing scan time and/or improving image and mapping quality. The methods exponential decay models, spatio-temporal finite differences, and low rank obtained the best results for radial sampling patterns.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Joelho/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Estudos Retrospectivos
13.
Magn Reson Med ; 84(5): 2636-2644, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32385949

RESUMO

PURPOSE: To implement a novel technique for simultaneous, quantitative multiparametric mapping of the knee articular cartilage. METHODS: A novel MR fingerprinting pulse sequence is proposed and implemented for simultaneous measurements of proton density, T1 , T2, and T1ρ relaxation times at 3T. The repeatability and reproducibility of the proposed technique were assessed in model phantoms. Institutional review board-approved MR fingerprinting imaging sequence was performed on healthy volunteers and patients with mild knee osteoarthritis. The Wilcoxon test was used to compare healthy controls and patients. The intra- and intersubject repeatability were assessed with coefficient of variation and the RMS coefficient of variation, respectively RESULTS: The Bland-Altman plots demonstrated an average difference of 4.67 ms, -0.09 ms, and 0.05 ms between 2 scans in the same scanner; and 9.68 ms, 0.29 ms, and -0.72 ms between the scans acquired on 2 different scanners for T1 , T2 , and T1ρ , respectively. The in vivo knee study showed excellent repeatability with RMS coefficient of variation less than 3%, 6%, and 5% for T1 , T2 , and T1ρ , respectively. The Wilcoxon test showed a significant difference between control and mild osteoarthritis patients for T1 (P = .04), T2 (P = .01), and T1ρ (P = .02) relaxation time in medial tibial cartilage, as well as for T2 relaxation time (P = .02) in medial femoral cartilage. CONCLUSION: The proposed MRF sequence is fast and can simultaneously measure the T1 , T2 , T1ρ , and B1+ maps in a single scan. It is able to discriminate between mild osteoarthritis patients and healthy volunteers.


Assuntos
Cartilagem Articular , Osteoartrite do Joelho , Cartilagem Articular/diagnóstico por imagem , Humanos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Osteoartrite do Joelho/diagnóstico por imagem , Reprodutibilidade dos Testes
14.
NMR Biomed ; 33(12): e4318, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32359000

RESUMO

NMR relaxometry can provide information about the relaxation of the magnetization in different tissues, increasing our understanding of molecular dynamics and biochemical composition in biological systems. In general, tissues have complex and heterogeneous structures composed of multiple pools. As a result, bulk magnetization returns to its original state with different relaxation times, in a multicomponent relaxation. Recovering the distribution of relaxation times in each voxel is a difficult inverse problem; it is usually unstable and requires long acquisition time, especially on clinical scanners. MRI can also be viewed as an inverse problem, especially when compressed sensing (CS) is used. The solution of these two inverse problems, CS and relaxometry, can be obtained very efficiently in a synergistically combined manner, leading to a more stable multicomponent relaxometry obtained with short scan times. In this paper, we will discuss the details of this technique from the viewpoint of inverse problems.


Assuntos
Imageamento por Ressonância Magnética , Algoritmos , Animais , Cartilagem Articular/diagnóstico por imagem , Bovinos , Fígado/diagnóstico por imagem , Imagens de Fantasmas
15.
J Magn Reson Imaging ; 51(2): 426-434, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31282080

RESUMO

BACKGROUND: Quantification of dynamic biomechanical strain in articular cartilage in vivo; in situ using noninvasive MRI techniques is desirable and may potentially be used to assess joint pathology. PURPOSE: To demonstrate the use of static mechanical loading and continuous 3D-MRI acquisition of the human knee joint in vivo to measure the strain in the tibiofemoral articular cartilage. STUDY TYPE: Prospective. SUBJECTS: Five healthy human volunteers (four women, one man; age 25.6 ± 1.7) underwent MRI at rest, under static mechanical loading condition, and during recovery. FIELD STRENGTH/SEQUENCE: A field strength of 3T was used. The sequence used was 3D-continuous golden angle radial sparse parallel (GRASP) MRI and compressed sensing (CS) reconstruction. ASSESSMENT: Tibiofemoral cartilage deformation maps under loading and during recovery were calculated using an optical flow algorithm. The corresponding Lagrangian strain was calculated in the articular cartilage. STATISTICAL TESTS: Range of displacement and strain in each subject, and the resulting mean and standard deviation, were calculated. RESULTS: During the loading condition, the cartilage displacement in the direction of loading ranged from a minimum of -673.6 ± 121.9 µm to a maximum of 726.5 ± 169.5 µm. Corresponding strain ranged from a minimum of -7.0 ± 4.2% to a maximum of 5.4 ± 1.6%. During the recovery condition, the cartilage displacement in the same direction reduced to a minimum of -613.0 ± 129.5 µm and a maximum of 555.7 ± 311.4 µm. The corresponding strain range reduced to a minimum of -1.6 ± 7.5% to a maximum of 4.2 ± 2.6%. DATA CONCLUSION: This study shows the feasibility of using static mechanical loading with continuous GRASP-MRI acquisition to measure the strain in the articular cartilage. By measuring strain during the loading and recovery phases, dynamic strain information in the articular cartilage might be able to be investigated. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:426-434.


Assuntos
Cartilagem Articular , Imageamento por Ressonância Magnética , Adulto , Cartilagem Articular/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Estudos Prospectivos , Adulto Jovem
16.
Magn Reson Med ; 80(4): 1475-1491, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29479738

RESUMO

PURPOSE: To evaluate the feasibility of using compressed sensing (CS) to accelerate 3D-T1ρ mapping of cartilage and to reduce total scan times without degrading the estimation of T1ρ relaxation times. METHODS: Fully sampled 3D-T1ρ datasets were retrospectively undersampled by factors 2-10. CS reconstruction using 12 different sparsifying transforms were compared, including finite differences, temporal and spatial wavelets, learned transforms using principal component analysis (PCA) and K-means singular value decomposition (K-SVD), explicit exponential models, low rank and low rank plus sparse models. Spatial filtering prior to T1ρ parameter estimation was also tested. Synthetic phantom (n = 6) and in vivo human knee cartilage datasets (n = 7) were included. RESULTS: Most CS methods performed satisfactorily for an acceleration factor (AF) of 2, with relative T1ρ error lower than 4.5%. Some sparsifying transforms, such as spatiotemporal finite difference (STFD), exponential dictionaries (EXP) and low rank combined with spatial finite difference (L+S SFD) significantly improved this performance, reaching average relative T1ρ error below 6.5% on T1ρ relaxation times with AF up to 10, when spatial filtering was used before T1ρ fitting, at the expense of smoothing the T1ρ maps. The STFD achieved 5.1% error at AF = 10 with spatial filtering prior to T1ρ fitting. CONCLUSION: Accelerating 3D-T1ρ mapping of cartilage with CS is feasible up to AF of 10 when using STFD, EXP or L+S SFD regularizers. These three best CS methods performed satisfactorily on synthetic phantom and in vivo knee cartilage for AFs up to 10, with T1ρ error of 6.5%.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Bases de Dados Factuais , Humanos , Imagens de Fantasmas , Adulto Jovem
17.
J Magn Reson Imaging ; 48(5): 1185-1198, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30295344

RESUMO

More than a decade after the introduction of compressed sensing (CS) in MRI, researchers are still working on ways to translate it into different research and clinical applications. The greatest advantage of CS in MRI is the reduced amount of k-space data needed to reconstruct images, which can be exploited to reduce scan time or to improve spatial resolution and volumetric coverage. Efficient data acquisition using CS is extremely important for compositional mapping of the musculoskeletal system in general and knee cartilage mapping techniques in particular. High-resolution quantitative information about tissue biochemical composition could be obtained in just a few minutes using CS MRI. However, in order to make this goal a reality, some issues still need to be addressed. In this article we review the current state of the art of CS methods for rapid compositional mapping of knee cartilage. Specifically, data acquisition strategies, image reconstruction algorithms, and data fitting models are discussed. Different CS studies for T2 and T1ρ mapping of knee cartilage are reviewed, with illustrative results. Future directions, opportunities, and challenges of rapid compositional mapping techniques are also discussed. Level of Evidence: 4 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2018;47:1185-1198.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Algoritmos , Compressão de Dados , Humanos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador
18.
Sensors (Basel) ; 17(3)2017 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-28282862

RESUMO

Ultrasonic image reconstruction using inverse problems has recently appeared as an alternative to enhance ultrasound imaging over beamforming methods. This approach depends on the accuracy of the acquisition model used to represent transducers, reflectivity, and medium physics. Iterative methods, well known in general sparse signal reconstruction, are also suited for imaging. In this paper, a discrete acquisition model is assessed by solving a linear system of equations by an ℓ 1 -regularized least-squares minimization, where the solution sparsity may be adjusted as desired. The paper surveys 11 variants of four well-known algorithms for sparse reconstruction, and assesses their optimization parameters with the goal of finding the best approach for iterative ultrasound imaging. The strategy for the model evaluation consists of using two distinct datasets. We first generate data from a synthetic phantom that mimics real targets inside a professional ultrasound phantom device. This dataset is contaminated with Gaussian noise with an estimated SNR, and all methods are assessed by their resulting images and performances. The model and methods are then assessed with real data collected by a research ultrasound platform when scanning the same phantom device, and results are compared with beamforming. A distinct real dataset is finally used to further validate the proposed modeling. Although high computational effort is required by iterative methods, results show that the discrete model may lead to images closer to ground-truth than traditional beamforming. However, computing capabilities of current platforms need to evolve before frame rates currently delivered by ultrasound equipments are achievable.

19.
Bioengineering (Basel) ; 11(3)2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38534511

RESUMO

Magnetic resonance imaging (MRI) stands as a vital medical imaging technique, renowned for its ability to offer high-resolution images of the human body with remarkable soft-tissue contrast. This enables healthcare professionals to gain valuable insights into various aspects of the human body, including morphology, structural integrity, and physiological processes. Quantitative imaging provides compositional measurements of the human body, but, currently, either it takes a long scan time or is limited to low spatial resolutions. Undersampled k-space data acquisitions have significantly helped to reduce MRI scan time, while compressed sensing (CS) and deep learning (DL) reconstructions have mitigated the associated undersampling artifacts. Alternatively, magnetic resonance fingerprinting (MRF) provides an efficient and versatile framework to acquire and quantify multiple tissue properties simultaneously from a single fast MRI scan. The MRF framework involves four key aspects: (1) pulse sequence design; (2) rapid (undersampled) data acquisition; (3) encoding of tissue properties in MR signal evolutions or fingerprints; and (4) simultaneous recovery of multiple quantitative spatial maps. This paper provides an extensive literature review of the MRF framework, addressing the trends associated with these four key aspects. There are specific challenges in MRF for all ranges of magnetic field strengths and all body parts, which can present opportunities for further investigation. We aim to review the best practices in each key aspect of MRF, as well as for different applications, such as cardiac, brain, and musculoskeletal imaging, among others. A comprehensive review of these applications will enable us to assess future trends and their implications for the translation of MRF into these biomedical imaging applications.

20.
Bioengineering (Basel) ; 10(9)2023 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-37760114

RESUMO

Magnetic Resonance Imaging (MRI) is an essential medical imaging modality that provides excellent soft-tissue contrast and high-resolution images of the human body, allowing us to understand detailed information on morphology, structural integrity, and physiologic processes. However, MRI exams usually require lengthy acquisition times. Methods such as parallel MRI and Compressive Sensing (CS) have significantly reduced the MRI acquisition time by acquiring less data through undersampling k-space. The state-of-the-art of fast MRI has recently been redefined by integrating Deep Learning (DL) models with these undersampled approaches. This Systematic Literature Review (SLR) comprehensively analyzes deep MRI reconstruction models, emphasizing the key elements of recently proposed methods and highlighting their strengths and weaknesses. This SLR involves searching and selecting relevant studies from various databases, including Web of Science and Scopus, followed by a rigorous screening and data extraction process using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. It focuses on various techniques, such as residual learning, image representation using encoders and decoders, data-consistency layers, unrolled networks, learned activations, attention modules, plug-and-play priors, diffusion models, and Bayesian methods. This SLR also discusses the use of loss functions and training with adversarial networks to enhance deep MRI reconstruction methods. Moreover, we explore various MRI reconstruction applications, including non-Cartesian reconstruction, super-resolution, dynamic MRI, joint learning of reconstruction with coil sensitivity and sampling, quantitative mapping, and MR fingerprinting. This paper also addresses research questions, provides insights for future directions, and emphasizes robust generalization and artifact handling. Therefore, this SLR serves as a valuable resource for advancing fast MRI, guiding research and development efforts of MRI reconstruction for better image quality and faster data acquisition.