Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Ultrasound Med ; 40(4): 779-786, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32951229

RESUMO

OBJECTIVES: Thyroid shear wave elastography (SWE) has been shown to have advantages compared to biopsy or other imaging modalities in the evaluation of thyroid nodules. However, studies show variability in its assessment. The objective of this study was to evaluate whether stiffness measurements of the normal thyroid, as estimated by SWE, varied due to preload force or the pressure applied between the transducer and the patient. METHODS: In this study, a measurement system was attached to the ultrasound transducer to measure the applied load. Shear wave elastographic measurements were obtained from the left lobe of the thyroid at applied transducer forces between 2 and 10 N. A linear mixed-effects model was constructed to quantify the association between the preload force and stiffness while accounting for correlations between repeated measurements within each participant. The preload force effect on elasticity was modeled by both linear and quadratic terms to account for a possible nonlinear association between these variables. RESULTS: Nineteen healthy volunteers without known thyroid disease participated in the study. The participants had a mean age ± SD of 36 ± 8 years; 74% were female; 74% had a normal body mass index; and 95% were white non-Hispanic/Latino. The estimated elastographic value at a 2-N preload force was 16.7 kPa (95% confidence interval, 14.1-19.3 kPa), whereas the value at 10 N was 29.9 kPa (95% confidence interval, 24.9-34.9 kPa). CONCLUSIONS: The preload force was significantly and nonlinearly associated with SWE estimates of thyroid stiffness. Quantitative standardization of preload forces in the assessment of thyroid nodules using elastography is an integral factor for improving the accuracy of thyroid nodule evaluation.


Assuntos
Técnicas de Imagem por Elasticidade , Nódulo da Glândula Tireoide , Elasticidade , Feminino , Humanos , Masculino , Nódulo da Glândula Tireoide/diagnóstico por imagem
2.
Biomed Microdevices ; 15(4): 645-655, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23515914

RESUMO

We report for the first time a microdevice that enables the selective enrichment, culture, and identification of tumor-initiating cells on native polydimethylsiloxane (PDMS). For nearly a decade, researchers have identified tumor-initiating breast cancer cells within heterogeneous populations of breast cancer cells by utilizing low-attachment serum-free culture conditions, which lead to the formation of spheroidal colonies (mammospheres) that are enriched for tumor-initiating cells. However, the utility of this assay has been limited by difficulties in combining this culture-plate-based technique with other cellular and molecular analyses. Integrating the mammosphere technique into a microsystem can enable it to be combined directly with a number of functions, such as cell sorting, drug screens, and molecular assays. In this work, we demonstrate mammosphere culture within a PDMS microdevice. We first prove that a native hydrophobic PDMS surface is as effective as commercial low-attachment plates at selectively promoting the formation of mammospheres. We then experimentally assess the PDMS microdevice. Time-lapse images of mammosphere formation within the microdevice show that mammospheres form from single cells or small clusters of cells. Following formation of the mammospheres, it is desirable to evaluate the cells within the spheroids for enrichment of tumor initiating cells. To perform assays such as this (which require the loading and rinsing of reagents) without flushing the cells (which are in suspension) from the device, the culture chamber is separated from a reagent reservoir by a commercially available microporous membrane, and thus reagents are exchanged between the reservoir and the culture chamber by diffusion only. Using this capability, we verify that the mammospheres are enriched for tumor initiating cells by staining aldehyde dehydrogenase activity, a cancer stem cell marker. To the best of our knowledge, this is the first assay that enables the direct observation of tumor-initiating cells within a suspended mammosphere.


Assuntos
Neoplasias da Mama/patologia , Técnicas de Cultura de Células/instrumentação , Microtecnologia/instrumentação , Células-Tronco Neoplásicas/patologia , Esferoides Celulares/citologia , Aldeído Desidrogenase/metabolismo , Biomarcadores Tumorais/metabolismo , Dimetilpolisiloxanos/química , Humanos , Indicadores e Reagentes/química , Células MCF-7 , Células-Tronco Neoplásicas/metabolismo , Reprodutibilidade dos Testes , Coloração e Rotulagem
3.
Ultrasound Med Biol ; 48(9): 1806-1821, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35811237

RESUMO

We develop, automate and evaluate a calibration-free technique to estimate human carotid artery blood pressure from force-coupled ultrasound images. After acquiring images and force, we use peak detection to align the raw force signal with an optical flow signal derived from the images. A trained convolutional neural network selects a seed point within the carotid in a single image. We then employ a region-growing algorithm to segment and track the carotid in subsequent images. A finite-element deformation model is fit to the observed segmentation and force via a two-stage iterative non-linear optimization. The first-stage optimization estimates carotid artery wall stiffness parameters along with systolic and diastolic carotid pressures. The second-stage optimization takes the output parameters from the first optimization and estimates the carotid blood pressure waveform. Diastolic and systolic measurements are compared with those of an oscillometric brachial blood pressure cuff. In 20 participants, average absolute diastolic and systolic errors are 6.2 and 5.6 mm Hg, respectively, and correlation coefficients are r = 0.7 and r = 0.8, respectively. Force-coupled ultrasound imaging represents an automated, standalone ultrasound-based technique for carotid blood pressure estimation, which motivates its further development and expansion of its applications.


Assuntos
Determinação da Pressão Arterial , Artérias Carótidas , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiologia , Humanos , Oscilometria , Ultrassonografia
4.
Ultrasound Med Biol ; 44(12): 2739-2748, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30228044

RESUMO

Described here is a method to determine the longitudinal speed of sound in speckle-dominated ultrasound images. The method is based on the concept that the quality of an ultrasound image is maximized when the beamformer's speed of sound matches the speed in the medium. The method captures the quality of the ultrasound image using two quantitative image-quality metrics: image brightness and sharpness around the intended focal zone. The proposed method requires no calibration, is computationally efficient and is deployable on commercial ultrasound systems without hardware or software modifications. Ex vivo testing on tissue-mimicking phantoms indicates the method's accuracy in predicting the true speed of sound to within 1% of ground truth values.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Imagens de Fantasmas , Ultrassonografia/métodos , Reprodutibilidade dos Testes
5.
Ultrasound Med Biol ; 44(12): 2461-2475, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30232020

RESUMO

Non-alcoholic fatty liver disease is a condition that is characterized by the presence of >5% fat in the liver and affects more than one billion people worldwide. If adequate and early precautions are not taken, non-alcoholic fatty liver disease can progress to cirrhosis and death. The current reference standard for detecting hepatic steatosis is a liver biopsy. However, because of the potential morbidity associated with liver biopsies, non-invasive imaging biomarkers have been extensively investigated. Magnetic resonance imaging-based methods have proven accuracy in quantifying liver steatosis; however, these techniques are costly and have limited availability. Ultrasound-based quantitative imaging techniques are increasingly utilized because of their widespread availability, ease of use and relative cost-effectiveness. Several ultrasound-based liver fat quantification techniques have been investigated, including techniques that measure changes in the acoustic properties of the liver caused by the presence of fat. In this review, we focus on quantitative ultrasound approaches and their diagnostic performance in the realm of non-alcoholic fatty liver disease.


Assuntos
Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Ultrassonografia/métodos , Estudos de Avaliação como Assunto , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
6.
Ultrasound Med Biol ; 44(12): 2749-2758, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30266215

RESUMO

This study validates a non-invasive, quantitative technique to diagnose steatosis within tissue. The proposed method is based on two fundamental concepts: (i) the speed of sound in a fatty liver is lower than that in a healthy liver and (ii) the quality of an ultrasound image is maximized when the beamformer's speed of sound matches the speed in the medium under examination. The method uses image brightness and sharpness as quantitative image-quality metrics to predict the true sound speed and capture the effects of fat infiltration, while accounting for the transmission through subcutaneous fat. Ex vivo testing on sheep liver, mouse livers and tissue-mimicking phantoms indicated the technique's ability to predict the true speed of sound with errors less than 0.5% and to quantify the inverse correlation between fat content and speed of sound.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia/métodos , Animais , Modelos Animais de Doenças , Fígado/diagnóstico por imagem , Camundongos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Ovinos
7.
Biomicrofluidics ; 8(2): 024105, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24738012

RESUMO

A spiral inertial filtration (SIFT) device that is capable of high-throughput (1 ml/min), high-purity particle separation while concentrating recovered target particles by more than an order of magnitude is reported. This device is able to remove large fractions of sample fluid from a microchannel without disruption of concentrated particle streams by taking advantage of particle focusing in inertial spiral microfluidics, which is achieved by balancing inertial lift forces and Dean drag forces. To enable the calculation of channel geometries in the SIFT microsystem for specific concentration factors, an equivalent circuit model was developed and experimentally validated. Large particle concentration factors were then achieved by maintaining either the average fluid velocity or the Dean number throughout the entire length of the channel during the incremental removal of sample fluid. The SIFT device was able to separate MCF7 cells spiked into whole blood from the non-target white blood cells (WBC) with a recovery of nearly 100% while removing 93% of the sample volume, which resulted in a concentration enhancement of the MCF7 cancer cells by a factor of 14.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA