Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38972630

RESUMO

OBJECTIVE: Challenging infrarenal aortic neck characteristics have been associated with increased risk of a type Ia endoleak after endovascular aneurysm repair (EVAR). Short apposition (< 10 mm circumferential shortest apposition length [SAL]) on the first post-operative computerised tomography angiography (CTA) has been associated with type Ia endoleak. Therefore, this study aimed to develop a model to predict post-operative SAL in patients with an abdominal aortic aneurysm based on the pre-operative shape. METHODS: A statistical shape model was developed to obtain principal component scores. The dataset comprised patients treated with standard EVAR without complications (n = 93) enriched with patients with a late type Ia endoleak (n = 54). The infrarenal SAL was obtained from the first post-operative CTA and subsequently binarised (< 10 mm and ≥ 10 mm). The principal component scores that were statistically different between the SAL groups were used as input for five classification models, and evaluated by means of leave one out cross validation. Area under the receiver operating characteristics curves (AUC), accuracy, sensitivity, and specificity were determined for each classification model. RESULTS: Of the 147 patients, 24 patients had an infrarenal SAL < 10 mm and 123 patients had a SAL ≥ 10 mm. The gradient boosting model resulted in the highest AUC of 0.77. Using this model, 114 (78.0%) patients were correctly classified; sensitivity (< 10 mm apposition was correctly predicted) and specificity (≥ 10 mm apposition was correctly predicted) were 0.70 and 0.79, and were based on a threshold of 0.21, respectively. CONCLUSION: A model was developed to predict which patients undergoing EVAR will achieve sufficient graft apposition (≥ 10 mm) in the infrarenal aortic neck based on a statistical shape model of pre-operative CTA data. This model can help vascular specialists during the planning phase to accurately identify patients who are unlikely to achieve sufficient apposition after standard EVAR.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38670221

RESUMO

OBJECTIVE: The Gore Excluder Conformable Endoprosthesis (CEXC) is designed to treat challenging infrarenal anatomy because of its active angulation control, repositionability, and enhanced conformability. This study evaluated 30 day and one year position and apposition of the CEXC in the infrarenal neck. METHODS: Patients treated with the CEXC between 2018 and 2022 with an available 30 day computed tomography angiogram (CTA) were selected from four hospitals in a prospective registry. Endograft apposition (shortest apposition length [SAL]) and position (shortest fabric distance [SFD]) were assessed on the 30 day and one year CTAs. Maximum infrarenal aortic curvature was compared between the pre- and post-operative CTAs to evaluate conformability of the CEXC. RESULTS: There were 87 patients with a 30 day CTA, and for 56 of these patients the one year CTA was available. Median (interquartile range [IQR]) pre-operative neck length was 22 mm (IQR 15, 32) and infrarenal angulation was 52° (IQR 31, 72). Median SAL was 21.2 mm (IQR 14.0, 29.3) at 30 days for all included patients. The SAL in 13 patients (15%) was < 10 mm at 30 days, and one patient had a SAL of 0 mm and a type Ia endoleak. There was no significant difference in SAL between patients within and outside instructions for use. The SAL significantly increased by 1.1 mm (IQR -2.3, 4.7; p = .042) at one year. The SAL decreased in seven patients (13%), increased in 13 patients (23%), and remained stable in 36 patients (64%). Median SFD was 2.0 mm (IQR 0.5, 3.6) at 30 days, which slightly increased by 0.3 mm (IQR -0.5, 1.8; p = .019) at one year. One patient showed migration (SFD increase ≥ 5 mm). Median endograft tilt was 15.8° (IQR 9.7, 21.4). Pre-operative maximum infrarenal curvature was 36 m-1 (IQR 26, 56) and did not significantly change thereafter. CONCLUSION: In most patients, the CEXC was implanted close to the renal arteries, and sufficient (≥ 10 mm) post-operative apposition was achieved at 30 days, which slightly increased at one year. Post-operative endograft tilt was relatively low, and aortic geometry remained unchanged after implantation of the CEXC, probably due to its high conformability.

3.
J Endovasc Ther ; 30(3): 449-460, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35297713

RESUMO

PURPOSE: The purpose of the study was to provide a consensus definition of the infrarenal sealing zone and develop an algorithm to determine when and if adjunctive procedure(s) or reintervention should be considered in managing patients undergoing endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm (AAA). METHODS: A European Advisory Board (AB), made up of 11 vascular surgeons with expertise in EVAR for AAA, was assembled to share their opinion regarding the definition of preoperative and postoperative infrarenal sealing zone. Information on their current clinical practice and level of agreement on proposed reintervention paths was used to develop an algorithm. The process included 2 virtual meetings and 2 rounds of online surveys completed by the AB (Delphi method). Consensus was defined as reached when ≥ 8 of 11 (73%) respondents agreed or were neutral. RESULTS: The AB reached complete consensus on definitions and measurement of the pre-EVAR target anticipated sealing zone (TASZ) and the post-EVAR real achieved sealing zone (RASZ), namely, the shortest length between the proximal and distal reference points as defined by the AB, in case of patients with challenging anatomies. Also, agreement was achieved on a list of 4 anatomic parameters and 3 prosthesis-/procedure-related parameters, considered to have the most significant impact on preoperative and postoperative sealing zones. Furthermore, the agreement was reached that in the presence of visible neck-related complications, both adjunctive procedure(s) and reintervention should be contemplated (100% consensus). In addition, adjunctive procedure(s) or reintervention can be considered in the following cases (% consensus): insufficient sealing zone on completion imaging (91%) or on the first postoperative computed tomography (CT) scan (91%), suboptimal sealing zone on completion imaging (73%) or postoperative CT scan (82%), and negative evolution of the actual sealing zone over time (91%), even in the absence of visible complications. CONCLUSIONS: AB members agreed on definitions of the pre- and post-EVAR infrarenal sealing zone, as well as factors of influence. Furthermore, a clinical decision algorithm was proposed to determine the timing and necessity of adjunctive procedure(s) and reinterventions.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Correção Endovascular de Aneurisma , Técnica Delphi , Consenso , Prova Pericial , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Fatores de Risco , Estudos Retrospectivos , Prótese Vascular
4.
J Endovasc Ther ; : 15266028221149913, 2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36647185

RESUMO

PURPOSE: Hostile aortic neck characteristics, including short length, severe suprarenal and infrarenal angulation, conicity, and large diameter, have been associated with increased risk for type Ia endoleak (T1aEL) after endovascular aneurysm repair (EVAR). This study investigates the mid-term discriminative ability of a statistical shape model (SSM) of the infrarenal aortic neck morphology compared with or in combination with conventional measurements in patients who developed T1aEL post-EVAR. MATERIALS AND METHODS: The dataset composed of EVAR patients who developed a T1aEL during follow-up and a control group without T1aEL. Principal component (PC) analysis was performed using a parametrization to create an SSM. Three logistic regression models were created. To discriminate between patients with and without T1aEL, sensitivity, specificity, and the area under the receiver operating characteristic (ROC) curve (AUC) were calculated. RESULTS: In total, 126 patients (84% male) were included. Median follow-up time in T1aEl group and control group was 52 (31, 78.5) and 51 (40, 62.5) months, respectively. Median follow-up time was not statistically different between the groups (p=0.72). A statistically significant difference between the median PC scores of the T1aEL and control groups was found for the first, eighth, and ninth PC. Sensitivity, specificity, and AUC values for the SSM-based versus the conventional measurements-based logistic regression models were 79%, 70%, and 0.82 versus 74%, 73%, and 0.85, respectively. The model of the SSM and conventional measurements combined resulted in sensitivity, specificity, and AUC of 81%, 81%, and 0.92. CONCLUSION: An SSM of the infrarenal aortic neck determines its 3-dimensional geometry. The SSM is a potential valuable tool for risk stratification and T1aEL prediction in EVAR. The SSM complements the conventional measurements of the individual preoperative infrarenal aortic neck geometry by increasing the predictive value for late type Ia endoleak after standard EVAR. CLINICAL IMPACT: A statistical shape model (SSM) determines the 3-dimensional geometry of the infrarenal aortic neck. The SSM complements the conventional measurements of the individual pre-operative infrarenal aortic neck geometry by increasing the predictive value for late type Ia endoleaks post-EVAR. The SSM is a potential valuable tool for risk stratification and late T1aEL prediction in EVAR and it is a first step toward implementation of a treatment planning support tool in daily clinical practice.

5.
J Endovasc Ther ; : 15266028221120514, 2022 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-36113063

RESUMO

PURPOSE: Imaging surveillance following endovascular aneurysm repair (EVAR) is strictly recommended. This study investigates the value of endograft apposition and position relative to the aortic neck on the first postoperative computed tomography angiography (CTA) in determining patients at risk for a late type Ia endoleak (T1aEL). MATERIALS AND METHODS: Patients with a T1aEL after the first postoperative CTA were selected from a consecutive database and matched with uncomplicated controls. Endograft apposition and position, including the shortest apposition length (SAL), were determined on the first postoperative CTA. The SAL is the shortest distance between the proximal endograft fabric and the first slice where circumferential apposition with the aortic wall is lost. Differences in endograft apposition at the first postoperative CTA were compared between groups. Logistic regression analysis identified independent predictors for late T1aEL. RESULTS: A total of 32 patients with a late T1aEL were included and matched with 32 uncomplicated controls. Median follow-up after primary EVAR was 62.0 (interquartile range [IQR]: 36.8, 83.5) months in the T1aEL group compared with 47.5 (IQR: 34.0, 79.3) months in the control group; p=0.265. Median preoperative neck diameter was significantly larger in the T1aEL group than in the control group (26.6 [IQR: 24.9, 29.6] mm versus 23.4 [IQR: 22.5, 25.3] mm); p<0.001. Patients in the T1aEL group had a median SAL of 11.6 (IQR: 4.3, 20.5) mm compared with 20.7 (IQR: 13.1, 24.9) mm in the control group; p=0.002. SAL <10mm on the first postoperative CTA (odds ratio [OR]: 9.63, 95% confidence interval [CI]: 1.60-57.99) and larger neck diameter (OR: 1.80, 95% CI: 1.26-2.57) were independent predictors for developing a late T1aEL. CONCLUSION: Preoperative neck diameter and SAL on the first postoperative CTA following EVAR are important predictors for the development of a late T1aEL. Patients with a SAL of <10mm had a significantly higher risk of developing a late T1aEL. Future research should determine whether these patients would benefit from reintervention before an actual T1aEL is present. CLINICAL IMPACT: Understanding the mechanisms of endovascular aneurysm repair failure is essential to further enhance clinical outcomes. Adequate proximal sealing is necessary to foster freedom from type 1a endoleak. This study demonstrates that the shortest apposition length (SAL) at the first postoperative computed tomography angiography (CTA) is able to identify patients at risk for a late type 1a endoleak. Especially patients with a SAL <10mm are at high risk. Currently, the guidelines advice repeated imaging with CTA in patients with a seal <10mm. Future research should determine whether these patients would benefit from re-intervention before an actual type 1a endoleak is present.

6.
Eur J Vasc Endovasc Surg ; 64(5): 475-488, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35988861

RESUMO

OBJECTIVE: Establishing the predictive value of neck characteristics and real achieved sealing zone is essential to foster risk stratified procedure selection and imaging surveillance. This systematic review provides an overview of pre-operative aortic neck characteristics and post-operative real achieved sealing zone and their respective risk of type 1a endoleak and migration after endovascular aneurysm repair (EVAR). METHODS: In agreement with PRISMA guidelines, MEDLINE, Embase, and Cochrane CENTRAL were searched. Data on neck characteristics, sealing zone, and EVAR outcome were extracted. Meta-analyses were performed to investigate the effect of neck diameter, angulation, and shape on type 1a endoleak (total, early ≤ 90 days, and late > 90 days) and migration in patients who underwent EVAR. A qualitative summary was also provided. RESULTS: Thirty-three studies were included. Patients with a larger neck diameter had an increased risk of total type 1a endoleak (nine studies: OR 3.32, 95% CI 2.38 - 4.63), early type 1a endoleak (six studies: OR 2.64, 95% CI 1.27 - 5.48), late type 1a endoleak (six studies: OR 3.26, 95% CI 2.12 - 5.03), and migration (seven studies: OR 2.88, 95% CI 1.32 - 6.26). An angulated neck increased the risk of total type 1a endoleak (seven studies: OR 4.27, 95% CI 1.55 - 11.78) and late type 1a endoleak (seven studies: OR 5.56, 95% CI 2.19 - 14.13). Neck shape was not associated with type 1a endoleak. Neck length and real achieved sealing zone on post-EVAR computed tomography were identified as risk factors for type 1a endoleak and migration through qualitative summary. CONCLUSION: There seems to be some consistent evidence that aortic neck diameter, angulation, and length are associated with the development of type 1a endoleak or migration. Real achieved sealing zone might be an important addition during follow up. However, a small number of studies, with serious limitations, could be included, and there was considerable variability in reporting patients and outcomes. A proposal for standardisation of aortic and EVAR data in future studies is provided.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Implante de Prótese Vascular/efeitos adversos , Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco
8.
J Clin Med ; 12(12)2023 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-37373662

RESUMO

Late type 1a endoleaks (T1aELs) after endovascular aneurysm repair (EVAR) are hazardous complications which should be avoided. This study investigated the evolution of the shortest apposition length (SAL) post-EVAR and hypothesised that a declining apposition during follow-up may be an indicator of T1aEL development. Patients with a late T1aEL were selected from a consecutive multicentre database. For each T1aEL patient, the preoperative computed tomography angiography (CTA), first postoperative CTA, and pre-endoleak CTA were analysed. T1aEL patients were matched 1:1 to uncomplicated controls, based on endograft type and follow-up duration. Anatomical characteristics and endograft dimensions, including the post-EVAR SAL, were measured. Included were 28 patients with a late T1aEL and 28 matched controls. The SAL decreased from 11.2 mm (5.6-20.6 mm) to 3.9 mm (0.0-11.4 mm) in the T1aEL group (p = 0.006), whereas an increase in SAL was seen in the control group from 21.3 mm (14.1-25.8 mm) to 25.4 mm (19.0-36.2 mm; p = 0.015). On the pre-endoleak CTA, 18 patients (64%) in the T1aEL group had a SAL < 10 mm, and one (4%) patient in the control group had a SAL < 10 mm on the matched CTAs. Moreover, three mechanisms of decreasing sealing zone were identified, which might be used to determine optimal imaging or reintervention strategies. Diminishing SAL < 10 mm is an indicator for T1aEL during follow-up, it is imperative to include apposition analysis during follow-up.

9.
J Cardiovasc Surg (Torino) ; 64(2): 150-158, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36897208

RESUMO

BACKGROUND: The GORE EXCLUDER Conformable Endoprosthesis with active control (CEXC) was developed to treat challenging aortic neck anatomy. This study investigated the clinical results and changes in endograft (ap)position during follow-up. METHODS: Patients treated with the CEXC between 2018 and 2022 were included in this prospective single-center study. Computed tomography angiography (CTA) follow-up was grouped into three categories: 0 to 6 (FU1), 7 to 18 (FU2), and 19 to 30 (FU3) months. Clinical end points were endograft-associated complications and reinterventions. CTA analysis included the shortest apposition length (SAL) between the endograft fabric and the first slice where circumferential apposition was lost, shortest fabric distance (SFD) between both renal arteries and the endograft fabric, and maximum infrarenal and suprarenal aortic curvature. FU2 and FU3 were compared with FU1 to establish changes. RESULTS: Included were 46 patients, of whom 36 (78%) had at least one hostile neck feature and 13 (28%) were treated outside instructions for use. Technical success was 100%. Median CTA follow-up was 10 months (2-20 months); 39 patients had a CTA available at FU1, 22 at FU2, and 12 at FU3. At FU1, the median SAL was 21.4 mm (13.2-27.4 mm), which did not significantly change during follow-up. No type I endoleaks, and one type III endoleak at an IBD occurred during follow-up. Two cases of endograft migration (SFD increase >10 mm) were seen during follow-up (one treated outside the instructions for use). Maximum infrarenal and suprarenal aortic curvature did not significantly change during follow-up. CONCLUSIONS: The use of the CEXC in challenging aortic necks enables stable apposition without significant changes in aortic morphology at short-term follow-up.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Estudos Prospectivos , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Estudos Retrospectivos , Desenho de Prótese
10.
J Cardiovasc Surg (Torino) ; 64(2): 134-141, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36987816

RESUMO

BACKGROUND: For descending thoracic aortic aneurysms (TAA) in proximity of the aortic arch, debranching of the left subclavian artery (LSA) may be necessary to extend proximal sealing in zone 2. The aim of this study was to determine the added proximal apposition length gained from LSA debranching during thoracic endovascular aortic repair (TEVAR). METHODS: This multicenter retrospective study (2010-2020) included patients who underwent elective TEVAR in zone 2 for a degenerative TAA where the LSA was surgically debranched. The endograft position on the first postoperative computed tomography angiography (CTA) scan was assessed using post-processing software. The analysis included the shortest apposition length (SAL), the tilt of the proximal edge of the endograft, and the distance between the endograft and the left common carotid artery. Clinical endpoints (neurological complications and endoleaks) at 30 days were also reported. RESULTS: Twenty-two patients were included. The median interval between TEVAR and the first postoperative CTA was 3 days (2-10 days). Median SAL was 9.2 mm (1.3-26.4 mm), of which 8.6 mm (1.3-16.2 mm) was gained proximal of the LSA, including the LSA orifice. In 12 patients (55.5%) the SAL was <10 mm. The median tilt was 18.3° (13.9°-22.2°). Seven endoleaks were reported on the first CTA: 1 type Ia, 2 type Ib, 3 type II, and 1 type III. CONCLUSIONS: Debranching the LSA adds valuable sealing length in zone 2, but the SAL was still relatively short in many patients, putting these patients at risk for a future type Ia endoleak. Accurate assessment of the circumferential apposition on postoperative CTA follow-up in these high-risk patients with short, complex landing zones seems mandatory. Evaluation of apposition in a larger population with longer follow-up is advised.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Correção Endovascular de Aneurisma , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Aortografia/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA