Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Int J Sports Med ; 38(5): 378-383, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28255967

RESUMO

This study aims to propose and validate the tethered swimming lactate minimum test (TSLacmin) estimating aerobic and anaerobic capacity in one single test session, using force as measurement parameter. 6 male and 6 female young swimmers (age=15.7±1.1 years; height=173.3±9.5 cm; weight=66.1±9.5 kg) performed 4 sessions comprising i) an all-out 30 s test and incremental test (TSLacmin); ii) 30 min of tethered swimming at constant intensity (2 sessions); iii) free-swimming time trials used to calculate critical velocity. Tethered swimming sessions used an acquisition system enabling maximum (Fmax) and mean (Fmean) force measurement and intensity variation. The tethered all-out test lasting 30 s resulted in hyperlactatemia of 7.9±2.0 mmol·l-1. TSLacmin presented a 100% success applicability rate, which is equivalent to aerobic capacity in 75% of cases. TSLacmin intensity was 37.7±7.3 N, while maximum force in the all-out test was 105±27 N. Aerobic and anaerobic TSLacmin parameters were significantly related to free-swimming performance (r=-0.67 for 100 m and r=-0.80 for 200 m) and critical velocity (r=0.80). TSLacmin estimates aerobic capacity in most cases, and both aerobic and anaerobic force parameters are well related to critical velocity and free swimming performance.


Assuntos
Limiar Anaeróbio/fisiologia , Teste de Esforço/métodos , Ácido Láctico/sangue , Natação/fisiologia , Adolescente , Feminino , Humanos , Masculino
2.
Sports Biomech ; : 1-17, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38979762

RESUMO

The Force-velocity (F-v) and Power-velocity (P-v) relationships quantify athlete's horizontal force production capacities during sprinting. Efforts are underway to enhance ecological validity for practitioners and sports coaches. This study provides detailed data comparison of a low frames per second setup (30 Hz; FPSlow) with splits from a high FPS camera to derive F-v and P-v relationships. Sixty-six sprints performed by 11 university track and field athletes (6 male, 5 female) were evaluated. Data were recorded using FPSlow, photocells, and a high-speed camera (240 Hz; MySprint). In the FPSlow setup, bias was 0.17s, and Limits of agreement was 0.09s compared to photocells. ICC was 1.00, and the coefficient of variation (CV) was 1.0% [0.8-1.1%]. Time acquisition comparison between MySprint and FPSlow setups revealed high consistency (ICC = 0.99) and low CV (2.9% [2.8-3.1%]). F-v profile variables exhibited biases from trivial to small, with ICC ranging from moderate to nearly perfect. CV ranged from 2.7% to 11.8%, and improved using the average of three sprints (CV between 1.8% and 8.6%). The 'simple method' applied to data from the low FPS video setup yielded kinetic and kinematic parameters comparable to those obtained by the validated previous method and photocells.

3.
Sci Rep ; 12(1): 1148, 2022 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-35064131

RESUMO

This study investigated the 30-days altitude training (2500 m, LHTH-live and training high) on hematological responses and aerobic-anaerobic performances parameters of high-level Paralympic athletes. Aerobic capacity was assessed by 3000 m run, and anaerobic variables (velocity, force and mechanical power) by a maximal 30-s semi-tethered running test (AO30). These assessments were carried out at low altitude before (PRE) and after LHTH (5-6 and 15-16 days, POST1 and POST2, respectively). During LHTH, hematological analyzes were performed on days 1, 12, 20 and 30. After LHTH, aerobic performance decreased 1.7% in POST1, but showed an amazing increase in POST2 (15.4 s reduction in the 3000 m test, 2.8%). Regarding anaerobic parameters, athletes showed a reduction in velocity, force and power in POST1, but velocity and power returned to their initial conditions in POST2. In addition, all participants had higher hemoglobin (Hb) values at the end of LHTH (30 days), but at POST2 these results were close to those of PRE. The centrality metrics obtained by complex networks (pondered degree, pagerank and betweenness) in the PRE and POST2 scenarios highlighted hemoglobin, hematocrit (Hct) and minimum force, velocity and power, suggesting these variables on the way to increasing endurance performance. The Jaccard's distance metrics showed dissimilarity between the PRE and POST2 graphs, and Hb and Hct as more prominent nodes for all centrality metrics. These results indicate that adaptive process from LHTH was highlighted by the complex networks, which can help understanding the better aerobic performance at low altitude after 16 days in Paralympic athletes.


Assuntos
Aclimatação/fisiologia , Desempenho Atlético/fisiologia , Hemoglobinas/metabolismo , Hipóxia/metabolismo , Paratletas , Adulto , Altitude , Anaerobiose/fisiologia , Brasil , Tolerância ao Exercício/fisiologia , Hemoglobinas/análise , Humanos , Hipóxia/sangue , Masculino , Consumo de Oxigênio/fisiologia , Resistência Física , Corrida/fisiologia
4.
Eur J Sport Sci ; 22(7): 1065-1072, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34003071

RESUMO

The present study tested the hypothesis that acute metformin would increase peak power measured during a Wingate test. Fourteen men (24 ± 6 years; 75.8 ± 10.2 kg; 177 ± 7 cm) participated in four test sessions, conducted in a crossover, counterbalanced, double-blind model. The first and second sessions consisted of anthropometric measurements and one Wingate test per day to assess test-retest reliability. In the last two sessions, the Wingate tests were performed on metformin (500 mg capsule, 1 hour before) or placebo (cellulose capsule, 1 hour before) condition. No differences were found between the placebo and metformin for peak power (1056.8 ± 215.8 W vs. 1095.2 ± 199.3 W, respectively; p = 0.24). Mean power (630.9 ± 87.8 W vs. 613.1 ± 94.8 W, respectively; p=0.01) and total work (18928 ± 2633 kJ vs. 18393 ± 2845 kJ, respectively; p = 0.01) in the metformin condition were higher than the placebo. The power were greater in metformin when compared to the placebo in moments 3 (p = 0.01), 4 (p = 0.01), 5 (p = 0.04), 6 (p = 0.04), 7 (p = 0.02), 8 (p = 0.03) and 9 (p = 0.01) seconds. There were no differences between conditions for the peak lactate (p = 0.08) and the rating of perceived exertion (p = 0.84). Acute metformin administration increased the early power phase and the mean power of a Wingate test.


Assuntos
Teste de Esforço , Metformina , Força Muscular , Adulto , Estudos Cross-Over , Voluntários Saudáveis , Humanos , Ácido Láctico/sangue , Masculino , Metformina/administração & dosagem , Esforço Físico , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA