Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int Braz J Urol ; 49(4): 411-427, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37267609

RESUMO

PURPOSE: To review and compare the effectivity of novel minimally invasive treatments (MITs) to transurethral resection of the prostate (TURP) for the treatment of lower urinary tract symptoms (LUTS) in men. METHODS: Medline, Embase, and Cochrane databases were searched from January 2010 to December 2022 for randomized controlled trials (RCTs) evaluating MITs, compared to TURP or sham, in men with LUTS. Studies were assessed by risk of bias tool, and evidence by GRADE. Functional outcomes by means of uroflowmetry and IPSS were the primary outcomes, safety and sexual function were secondary outcomes. As part of this review, a network meta-analysis (NMA) was conducted. MITs were ranked based on functional outcome improvement probability. RESULTS: In total, 10 RCTs were included, evaluating aquablation, prostatic urethral lift, prostatic artery embolization (PAE), convective water vapor thermal treatment or temporary implantable nitinol device. All MITs showed a better safety profile compared to TURP. Functional outcome improvement following aquablation were comparable to TURP. In the NMA, aquablation was ranked highest, PAE followed with the second highest probability to improve functional outcomes. Other novel MITs resulted in worse functional outcomes compared to TURP. Level of evidence was low to very low. CONCLUSIONS: Five MITs for treatment of LUTS were identified. Aquablation is likely to result in functional outcomes most comparable to TURP. Second in ranking was PAE, a technique that does not require general or spinal anesthesia. MITs have a better safety profile compared to TURP. However, due to high study heterogeneity, results should be interpreted with caution.


Assuntos
Sintomas do Trato Urinário Inferior , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Masculino , Humanos , Hiperplasia Prostática/complicações , Hiperplasia Prostática/cirurgia , Hiperplasia Prostática/diagnóstico , Metanálise em Rede , Resultado do Tratamento , Próstata/cirurgia , Ressecção Transuretral da Próstata/métodos , Sintomas do Trato Urinário Inferior/cirurgia
2.
J Org Chem ; 87(4): 2075-2086, 2022 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-34652911

RESUMO

Route design and proof of concept synthesis was conducted on a synthetically challenging atropisomeric KRASG12C inhibitor to support clinical API manufacture. Improvements to the synthesis of a chiral piperazine fragment gave reduced step count and streamlined protecting group strategy via the formation and methanol ring opening of an N-carboxy-anhydride (NCA). The complex atropisomeric nitroquinoline was accessed via an early stage salt-resolution followed by a formal two-part nitromethane-carbonylation, avoiding a high temperature Gould-Jacobs cyclization that previously led to atropisomer racemization. The substrate scope of the formal nitromethane-carbonylation strategy was further explored for a range of ortho-substituted bromo/iodo unprotected anilines.


Assuntos
Proteínas Proto-Oncogênicas p21(ras) , Metano/análogos & derivados , Nitroparafinas
3.
Respiration ; 101(11): 1006-1014, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36044868

RESUMO

BACKGROUND: Patients with interstitial lung diseases (ILDs) frequently present with nondiagnostic high-resolution CT (HRCT) scan and bronchoalveolar lavage (BAL) results, resulting in the need for invasive surgical or cryo-lung biopsy that is associated with significant morbidity. Confocal laser endomicroscopy (CLE) and optical coherence tomography (OCT) are high-resolution laser and light-based techniques that provide real-time imaging of the alveolar compartment during bronchoscopy with a different depth and field of view. OBJECTIVES: The aim of the study was to correlate OCT and CLE imaging to HRCT imaging in ILD. METHODS: This is a retrospective case series of 20 ILD patients who underwent alveolar CLE and OCT imaging during a standard bronchoscopy with BAL, followed by a lung biopsy when indicated. CLE and OCT imaging were compared to four main HRCT patterns and histology. The final diagnosis was based on the multidisciplinary discussion diagnosis. RESULTS: Bronchoscopic CLE and OCT imaging were feasible and safe and provided additional high-detailed anatomical information compared to the HRCT. Bronchoscopic real-time CLE was capable of identification of "alveolar cells" (ground glass opacities) and lung fibrosis (increased alveolar elastin fibers). Bronchoscopic real-time OCT allowed for visualization of "patchy fibrotic disease", "honeycombing" (microcysts), and mucosal granulomas in the airways. CONCLUSIONS: Bronchoscopic CLE and OCT of the alveolar compartment is feasible and safe and enables minimally invasive, high-resolution detection of specific ILD features with the potential to improve ILD diagnostics and monitoring and decrease the need for surgical or cryo-lung biopsies.


Assuntos
Doenças Pulmonares Intersticiais , Humanos , Estudos Retrospectivos , Doenças Pulmonares Intersticiais/diagnóstico , Broncoscopia/métodos , Lavagem Broncoalveolar , Biópsia/métodos
4.
Am J Pathol ; 190(7): 1483-1490, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32283104

RESUMO

Accurate grading of non-muscle-invasive urothelial cell carcinoma is of major importance; however, high interobserver variability exists. A fully automated detection and grading network based on deep learning is proposed to enhance reproducibility. A total of 328 transurethral resection specimens from 232 patients were included, and a consensus reading by three specialized pathologists was used. The slides were digitized, and the urothelium was annotated by expert observers. The U-Net-based segmentation network was trained to automatically detect urothelium. This detection was used as input for the classification network. The classification network aimed to grade the tumors according to the World Health Organization grading system adopted in 2004. The automated grading was compared with the consensus and individual grading. The segmentation network resulted in an accurate detection of urothelium. The automated grading shows moderate agreement (κ = 0.48 ± 0.14 SEM) with the consensus reading. The agreement among pathologists ranges between fair (κ = 0.35 ± 0.13 SEM and κ = 0.38 ± 0.11 SEM) and moderate (κ = 0.52 ± 0.13 SEM). The automated classification correctly graded 76% of the low-grade cancers and 71% of the high-grade cancers according to the consensus reading. These results indicate that deep learning can be used for the fully automated detection and grading of urothelial cell carcinoma.


Assuntos
Carcinoma de Células de Transição/patologia , Aprendizado Profundo , Gradação de Tumores/métodos , Patologia Clínica/métodos , Neoplasias da Bexiga Urinária/patologia , Humanos
5.
Chemistry ; 27(16): 5191-5204, 2021 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-33326655

RESUMO

We present the synthesis and coordination chemistry of a bulky, tripodal N,N,O ligand, ImPh2 NNOtBu (L), designed to model the 2-His-1-carboxylate facial triad (2H1C) by means of two imidazole groups and an anionic 2,4-di-tert-butyl-subtituted phenolate. Reacting K-L with MCl2 (M = Fe, Zn) affords the isostructural, tetrahedral non-heme complexes [Fe(L)(Cl)] (1) and [Zn(L)(Cl)] (2) in high yield. The tridentate N,N,O ligand coordination observed in their X-ray crystal structures remains intact and well-defined in MeCN and CH2 Cl2 solution. Reacting 2 with NaSPh affords a tetrahedral zinc thiolate complex, [Zn(L)(SPh)] (4), that is relevant to isopenicillin N synthase (IPNS) biomimicry. Cyclic voltammetry studies demonstrate the ligand's redox non-innocence, where phenolate oxidation is the first electrochemical response observed in K-L, 2 and 4. However, the first electrochemical oxidation in 1 is iron-centred, the assignment of which is supported by DFT calculations. Overall, ImPh2 NNOtBu provides access to well-defined mononuclear, monoligated, N,N,O-bound metal complexes, enabling more accurate structural modelling of the 2H1C to be achieved.

6.
Eur Respir J ; 53(6)2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31023849

RESUMO

Diagnosing lung cancer in the absence of endobronchial abnormalities is challenging. Needle-based confocal laser endomicroscopy (nCLE) enables real-time microscopic imaging of cells. We assessed the feasibility and safety of using nCLE for real-time identification of lung cancer.In patients with suspected or proven lung cancer scheduled for endoscopic ultrasound (EUS), lung tumours and mediastinal lymph nodes were imaged with nCLE before fine-needle aspiration (FNA) was performed. nCLE lung cancer characteristics were identified by comparison with pathology. Multiple blinded raters validated CLE videos of lung tumours and mediastinal nodes twice.EUS-nCLE-FNA was performed in 22 patients with suspected or proven lung cancer in whom 27 lesions (six tumours, 21 mediastinal nodes) were evaluated without complications. Three nCLE lung cancer criteria (dark enlarged pleomorphic cells, dark clumps and directional streaming) were identified. The accuracy of nCLE imaging for detecting malignancy was 90% in tumours and 89% in metastatic lymph nodes. Both inter-observer agreement (mean κ=0.68, 95% CI 0.66-0.70) and intra-observer agreement (mean±sd κ=0.70±0.15) were substantial.Real-time lung cancer detection by endosonography-guided nCLE was feasible and safe. Lung cancer characteristics were accurately recognised.


Assuntos
Biópsia por Agulha/métodos , Endossonografia/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Microscopia Confocal/métodos , Idoso , Estudos Transversais , Feminino , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Masculino , Mediastino/diagnóstico por imagem , Mediastino/patologia , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Países Baixos
7.
Respiration ; 97(3): 259-263, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30428462

RESUMO

BACKGROUND: Transbronchial cryobiopsy (TBCB) of the lung parenchyma is a minimally invasive alternative for surgical lung biopsy in interstitial lung disease (ILD) patients. Drawbacks are the nondiagnostic rate and complication risk of pneumothorax and bleeding. Fluoroscopy is the current guidance tool for TBCB, which is limited by 2D imaging and a radiation dose for the patient. Confocal laser endomicroscopy (CLE) is a high-resolution imaging technique that provides immediate feedback during bronchoscopy about the elastin fiber network of peripheral lung areas. Both the visceral pleura and fibrotic lung areas consist of elastin fibers and are therefore potentially detectable with CLE. OBJECTIVES: To investigate whether CLE is capable of (1) distinguishing fibrotic from normal alveolar areas and (2) identifying the pleura. METHODS: In and ex vivo CLE imaging obtained during bronchoscopy was compared with histology of lung biopsies in 14 ILD patients. RESULTS: CLE imaging of the alveolar compartment was feasible in all patients without adverse events. Based on CLE imaging, key characteristics that influence both diagnostic yield (dense fibrotic areas) and complication rate (pleura and subpleural space) were visualized. CONCLUSIONS: CLE seems a promising alternative to fluoroscopy as a guidance tool for TBCB procedures.


Assuntos
Biópsia/métodos , Criocirurgia/métodos , Doenças Pulmonares Intersticiais/diagnóstico , Pulmão/patologia , Microscopia Confocal/métodos , Broncoscopia/métodos , Feminino , Seguimentos , Humanos , Doenças Pulmonares Intersticiais/cirurgia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
8.
Lasers Surg Med ; 51(5): 399-406, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30919487

RESUMO

INTRODUCTION: With catheter based optical coherence tomography (OCT), high resolution images of the upper urinary tract can be obtained, thereby facilitating the detection of upper tract urothelial carcinomas (UTUC). We hypothesized that the attenuation coefficient of the OCT signal (µOCT ) is related to the histopathologic grade of the tumor. OBJECTIVES: In this study, we aimed to define the µOCT cut-off for discriminating high grade and low grade papillary UTUC. METHODS: For this post-hoc analysis, data from OCT imaging of papillary UTUC was obtained from patients during ureterorenoscopy. OCT images and raw data were simultaneously analyzed with in-house developed software. The µOCT determined in papillary UTUCs and corresponding histopathologic grading from either biopsies or radical resection specimens were compared. RESULTS: Thirty-five papillary UTUC from 35 patients were included. µOCT analysis was feasible in all cases. The median µOCT was 3.3 mm-1 (IQR 2.7-3.7 mm-1 ) for low-grade UTUC and 4.9 mm-1 (IQR 4.3-6.1 mm-1 ) for high-grade UTUC (P = 0.004). ROC analysis yielded a µOCT cut-off value of >4.0 mm-1 (AUC = 0.85, P < 0.001) with a sensitivity of 83% and a specificity of 94% for high-grade papillary UTUC. CONCLUSIONS: This study proposes a µOCT cut-off of 4.0 mm-1 for quantitative grading of UTUC with ureterorenoscopic OCT imaging. The promising diagnostic accuracy calculations justify further studies to validate the proposed cut-off value. Implementation of the software for the µOCT analysis in OCT systems may allow for µOCT assessment at real time during ureterorenoscopy. Lasers Surg. Med. 51:399-406, 2019. © 2019 Wiley Periodicals, Inc.

9.
Lasers Surg Med ; 51(5): 390-398, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31090088

RESUMO

OBJECTIVE: To demonstrate the safety and feasibility of clinical in vivo needle-based optical coherence tomography (OCT) imaging of the prostate. MATERIALS AND METHODS: Two patients with prostate cancer underwent each two percutaneous in vivo needle-based OCT measurements before transperineal template mapping biopsy. The OCT probe was introduced via a needle and positioned under ultrasound guidance. To test the safety, adverse events were recorded during and after the procedure. To test the feasibility, OCT and US images were studied during and after the procedure. Corresponding regions for OCT and biopsy were determined. A uropathologist evaluated and annotated the histopathology. Three experts assessed all the corresponding OCT images. The OCT and biopsy conclusions for the corresponding regions were compared. RESULTS: No adverse events during and following the, in total four, in vivo needle-based OCT measurements were reported. The OCT measurements showed images of prostatic tissue with a penetration depth of ~1.5 mm. The histological-proven tissue types, which were also found in the overlapping OCT images, were benign glands, stroma, glandular atrophy, and adenocarcinoma (Gleason pattern 3). CONCLUSIONS: Clinical in vivo needle-based OCT of the prostate is feasible with no adverse events during measurements. OCT images displayed detailed prostatic tissue with a imaging depth up to ~1.5 mm. We could co-register four histological-proven tissue types with OCT images. The feasibility of in vivo OCT in the prostate opens the pathway to the next phase of needle-based OCT studies in the prostate. Lasers Surg. Med. 51:390-398, 2019. © 2019 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.

10.
J Med Internet Res ; 21(7): e13490, 2019 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-31267983

RESUMO

BACKGROUND: Patient-reported outcome measures (PROMs) are increasingly used to measure patient's perspective of functional well-being, disease burden, treatment effectiveness, and clinical decision making. Electronic versions are increasingly feasible because of smartphone and tablet usage. However, validation of these electronic PROMs (ePROMs) is warranted for justified implementation. The International Index of Erectile Function (IIEF) 5 and 15 are widely used PROMs in urology to measure erectile dysfunction. Measurement reliability and validity testing of the IIEF ePROMs are essential before clinical application. OBJECTIVE: The aim of this study was to assess reliability and validity of an ePROM version of both IIEF-5 and 15. METHODS: This study included 179 patients from our urology outpatient clinic. It also had a randomized crossover design-participants completed either a paper and electronic IIEF-5 or 15 or twice completed an electronic version-with a 5-day delay. Internal consistency was assessed using Cronbach alpha and Spearman-Brown coefficient, test-retest reliability using the intraclass correlation coefficient (ICC), and convergent validity using the Pearson and Spearman correlation coefficient. RESULTS: A total of 122 participants completed the study. Internal consistency was excellent for the electronic IIEF-5 (ICC 0.902) and good to excellent for the domains of the IIEF-15 (ICC 0.962-0.834). Test-retest reliability was excellent for the IIEF-5 (ICC 0.924) and good to excellent for the domains of the IIEF-15 (ICC 0.950-0.778). Convergent validity was excellent for the IIEF-5 and IIEF-15, with a correlation of r=0.923 and r=0.951, respectively. CONCLUSIONS: We successfully introduced patient-acceptable ePROM versions of the IIEF-5 and IIEF-15. This study's results demonstrate that the ePROM versions of the IIEF-5 and IIEF-15 can be reliably implemented, as outcomes are reliable and in accordance with findings of the paper version. TRIAL REGISTRATION: ClinicalTrials.gov NCT03222388; https://clinicaltrials.gov/ct2/show/NCT03222388.


Assuntos
Disfunção Erétil/classificação , Medidas de Resultados Relatados pelo Paciente , Psicometria/métodos , Índice de Gravidade de Doença , Adulto , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Inquéritos e Questionários , Telemedicina
11.
World J Urol ; 36(4): 549-555, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29396786

RESUMO

Due to the growing field of digital pathology, more and more digital histology slides are becoming available. This improves the accessibility, allows teleconsultations from specialized pathologists, improves education, and might give urologist the possibility to review the slides in patient management systems. Moreover, by stacking multiple two-dimensional (2D) digital slides, three-dimensional volumes can be created, allowing improved insight in the growth pattern of a tumor. With the addition of computer-aided diagnosis systems, pathologist can be guided to regions of interest, potentially reducing the workload and interobserver variation. Digital (3D) pathology has the potential to improve dialog between the pathologist and urologist, and, therefore, results in a better treatment selection for urologic patients.


Assuntos
Diagnóstico por Computador , Técnicas de Diagnóstico Urológico/tendências , Doenças Urológicas/patologia , Computadores , Diagnóstico por Computador/instrumentação , Diagnóstico por Computador/métodos , Humanos , Imageamento Tridimensional
12.
Respiration ; 96(6): 564-570, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30110691

RESUMO

BACKGROUND: Bronchial thermoplasty (BT) is an endoscopic treatment for severe asthma targeting airway smooth muscle (ASM) with radiofrequent energy. Although implemented worldwide, the effect of BT treatment on the airways is unclear. Optical coherence tomography (OCT) is a novel imaging technique, based on near-infrared light, that generates high-resolution cross-sectional airway wall images. OBJECTIVE: To assess the safety and feasibility of OCT in severe asthma patients and determine acute airway effects of BT by OCT and compare these to the untreated right middle lobe (RML). METHODS: Severe asthma patients were treated with BT (TASMA trial). During the third BT procedure, OCT imaging was performed immediately following BT in the airways of the upper lobes, the right lower lobe treated 6 weeks prior, and the untreated RML. RESULTS: 57 airways were imaged in 15 patients. No adverse events occurred. Three distinct OCT patterns were discriminated: low-intensity scattering pattern of (1) bronchial and (2) peribronchial edema and (3) high-intensity scattering pattern of epithelial sloughing. (Peri)bronchial edema was seen in all BT-treated airways, and less pronounced in only 1/3 of the RML airways. These effects extended beyond the ASM layer and more distal than the directly BT-treated areas and were reduced, but not resolved, after 6 weeks. Epithelial sloughing occurred in 11/14 of the BT-treated airways and was absent in untreated RML airways. CONCLUSIONS: Acute BT effects can be safely assessed with OCT and 3 distinct patterns were identified. The acute effects extended beyond the targeted ASM layer and distal of directly BT-treated airway areas, suggesting that BT might also target smaller distal airways.


Assuntos
Asma/cirurgia , Brônquios/diagnóstico por imagem , Termoplastia Brônquica , Tomografia de Coerência Óptica , Adulto , Broncoscopia , Estudos de Coortes , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
14.
Lasers Surg Med ; 50(10): 980-986, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29882233

RESUMO

BACKGROUND AND OBJECTIVES: A 36-year-old woman underwent CO2 laser resurfacing for periocular rhytides using protective stainless steel Cox II ocular shields. Immediately after the treatment, corneal lesions were seen in both eyes. The left eye subsequent developed corneal ulceration and scarring, a deformed iris, cataract, and lower eye lashes showing signs of acute burns. The right cornea had a small inferior mid-peripheral superficial lesion and concomitant lower mid-peripheral burned eye lashes. Our objective was to determine the most likely cause of these ocular complications. STUDY: We estimated temperature-time combinations that could induce corneal injury and cataract. Heat conduction effects from a heated cornea to the lens and from a heated ring of periocular skin to the cornea were computed. The temperature response of a shield following CO2 laser irradiation was determined. RESULTS: We computed that cataract can develop when the corneal temperature reaches, for example, 80 °C for 14 seconds. A periocular ring of heated skin contributes little to the corneal temperature. After 7 pulses of consecutive CO2 laser bursts in 7.5 seconds, the total shield area already reached a homogeneous temperature of 63 °C. CONCLUSION: Despite uncertainties in procedural details and modeling of cataract temperatures, the eye injuries were caused beyond doubt by heating of tear-covered metal eye shields by at least 10 consecutive but unintentional laser impacts. Lasers Surg. Med. 50:980-986, 2018. © 2018 Wiley Periodicals, Inc.


Assuntos
Catarata/etiologia , Lesões da Córnea/etiologia , Dispositivos de Proteção dos Olhos/efeitos adversos , Terapia a Laser/efeitos adversos , Lasers de Gás , Ritidoplastia/efeitos adversos , Adulto , Dióxido de Carbono , Feminino , Temperatura Alta , Humanos , Aço Inoxidável
15.
Sensors (Basel) ; 18(5)2018 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-29693606

RESUMO

In this study; an OCT-based intra-operative imaging method for blood flow detection during esophagectomy with gastric tube reconstruction is investigated. Change in perfusion of the gastric tube tissue can lead to ischemia; with a high morbidity and mortality as a result. Anastomotic leakage (incidence 5⁻20%) is one of the most severe complications after esophagectomy with gastric tube reconstruction. Optical imaging techniques provide for minimal-invasive and real-time visualization tools that can be used in intraoperative settings. By implementing an optical technique for blood flow detection during surgery; perfusion can be imaged and quantified and; if needed; perfusion can be improved by either a surgical intervention or the administration of medication. The feasibility of imaging gastric microcirculation in vivo using optical coherence tomography (OCT) during surgery of patients with esophageal cancer by visualizing blood flow based on the speckle contrast from M-mode OCT images is studied. The percentage of pixels exhibiting a speckle contrast value indicative of flow was quantified to serve as an objective parameter to assess blood flow at 4 locations on the reconstructed gastric tube. Here; it was shown that OCT can be used for direct blood flow imaging during surgery and may therefore aid in improving surgical outcomes for patients.


Assuntos
Tomografia de Coerência Óptica , Neoplasias Esofágicas , Esofagectomia , Humanos , Microcirculação , Estômago
16.
J Urol ; 195(5): 1578-1585, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26719027

RESUMO

PURPOSE: We determine the ability of percutaneous needle based optical coherence tomography to differentiate renal masses by using the attenuation coefficient (µOCT, mm(-1)) as a quantitative measure. MATERIALS AND METHODS: Percutaneous needle based optical coherence tomography of the kidney was performed in patients presenting with a solid renal mass. A pathology specimen was acquired in the form of biopsies and/or a resection specimen. Optical coherence tomography results of 40 patients were correlated to pathology results of the resected specimens in order to derive µOCT values corresponding with oncocytoma and renal cell carcinoma, and with the 3 main subgroups of renal cell carcinoma. The sensitivity and specificity of optical coherence tomography in differentiating between oncocytoma and renal cell carcinoma were assessed through ROC analysis. RESULTS: The median µOCT of oncocytoma (3.38 mm(-1)) was significantly lower (p=0.043) than the median µOCT of renal cell carcinoma (4.37 mm(-1)). ROC analysis showed a µOCT cutoff value of greater than 3.8 mm(-1) to yield a sensitivity, specificity, positive predictive value and negative predictive value of 86%, 75%, 97% and 37%, respectively, to differentiate between oncocytoma and renal cell carcinoma. The area under the ROC curve was 0.81. Median µOCT was significantly lower for oncocytoma vs clear cell renal cell carcinoma (3.38 vs 4.36 mm(-1), p=0.049) and for oncocytoma vs papillary renal cell carcinoma (3.38 vs 4.79 mm(-1), p=0.027). CONCLUSIONS: We demonstrated that the µOCT is significantly higher in renal cell carcinoma vs oncocytoma, with ROC analysis showing promising results for their differentiation. This demonstrates the potential of percutaneous needle based optical coherence tomography to help in the differentiation of renal masses, thus warranting ongoing research.


Assuntos
Carcinoma de Células Renais/diagnóstico , Neoplasias Renais/diagnóstico , Rim/patologia , Agulhas , Tomografia de Coerência Óptica/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias/métodos , Projetos Piloto , Curva ROC
17.
BMC Cancer ; 16: 299, 2016 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-27150293

RESUMO

BACKGROUND: Current surgical and ablative treatment options for prostate cancer (PCa) may result in a high incidence of (temporary) incontinence, erectile dysfunction and/or bowel damage. These side effects are due to procedure related effects on adjacent structures including blood vessels, bowel, urethra and/or neurovascular bundle. Ablation with irreversible electroporation (IRE) has shown to be effective and safe in destroying PCa cells and also has the potential advantage of sparing surrounding tissue and vital structures, resulting in less impaired functional outcomes and maintaining men's quality of life. METHODS/DESIGN: In this randomized controlled trial (RCT) on IRE in localized PCa, 200 patients with organ-confined, unilateral (T1c-T2b) low- to intermediate-risk PCa (Gleason sum score 6 and 7) on transperineal template-mapping biopsies (TTMB) will be included. Patients will be randomized into focal or extended ablation of cancer foci with IRE. Oncological efficacy will be determined by multiparametric Magnetic Resonance Imaging, Contrast-Enhanced Ultrasound imaging if available, TTMP and Prostate Specific Antigen (PSA) follow-up. Patients will be evaluated up to 5 years on functional outcomes and quality of life with the use of standardized questionnaires. DISCUSSION: There is critical need of larger, standardized RCTs evaluating long-term oncological and functional outcomes before introducing IRE and other focal therapy modalities as an accepted and safe therapeutic option for PCa. This RCT will provide important short- and long-term data and elucidates the differences between focal or extended ablation of localized, unilateral low- to intermediate-risk PCa with IRE. TRIAL REGISTRATION: Clinicaltrials.gov database registration number NCT01835977. The Dutch Central Committee on Research Involving Human Subjects registration number NL50791.018.14.


Assuntos
Técnicas de Ablação/métodos , Eletroporação/métodos , Neoplasias da Próstata/terapia , Técnicas de Ablação/efeitos adversos , Adulto , Idoso , Biópsia , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Próstata/patologia , Neoplasias da Próstata/patologia , Resultado do Tratamento
18.
Gastrointest Endosc ; 83(1): 80-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26124075

RESUMO

BACKGROUND AND AIMS: The prevalence and clinical relevance of buried Barrett's glands (BB) after radiofrequency ablation (RFA) in Barrett's esophagus (BE) are debated. Recent optical coherence tomography studies demonstrated a high prevalence of BBs. Direct histological correlation, however, has been lacking. Volumetric laser endomicroscopy (VLE) is a second-generation optical coherence tomography system capable of scanning a large surface of the esophageal wall layers with low-power microscopy resolution. The aim was to evaluate whether post-RFA subsquamous glandular structures (SGSs), detected with VLE, actually correspond to BBs by pursuing direct histological correlation with VLE images. METHODS: In vivo VLE was performed to detect SGSs in patients with endoscopic regression of BE post-RFA. A second in vivo VLE scan was performed to confirm correct delineation of the SGSs. After endoscopic resection, the specimens were imaged ex vivo with VLE. Extensive histological sectioning of SGS areas was performed, and all histology slides were evaluated by an expert BE pathologist. RESULTS: Seventeen patients underwent successful in vivo VLE (histological diagnosis before endoscopic treatment: early adenocarcinoma in 8 patients and high-grade dysplasia in 9). In 4 of 17 patients, no SGSs were identified during VLE, and a random resection was performed. In the remaining 13 patients (76%), VLE detected SGS areas, which were all confirmed on a second in vivo VLE scan and subsequently resected. Most SGSs identified by VLE corresponded to normal histological structures (eg, dilated glands and blood vessels). However, 1 area containing BBs was found on histology. No specific VLE features to distinguish between BBs and normal SGSs were identified. CONCLUSIONS: VLE is able to detect subsquamous esophageal structures. One area showed BBs beneath endoscopically normal-appearing neosquamous epithelium; however, most post-RFA SGSs identified by VLE correspond to normal histological structures. ( CLINICAL TRIAL REGISTRATION NUMBER: NTR4056.).


Assuntos
Adenocarcinoma/patologia , Esôfago de Barrett/patologia , Ablação por Cateter , Neoplasias Esofágicas/patologia , Esôfago/patologia , Mucosa/patologia , Adenocarcinoma/cirurgia , Idoso , Esôfago de Barrett/cirurgia , Neoplasias Esofágicas/cirurgia , Esofagoscopia , Feminino , Humanos , Microscopia Intravital , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Gradação de Tumores , Tomografia de Coerência Óptica , Resultado do Tratamento
19.
J Vasc Interv Radiol ; 27(3): 433-43, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26703782

RESUMO

PURPOSE: Irreversible electroporation (IRE) uses high-voltage electric fields to achieve cell death. Although the mechanism of IRE is mainly designated as nonthermal, development of secondary Joule heating is inevitable. The study purpose was to gain understanding of temperature development and distribution during IRE. MATERIALS AND METHODS: IRE was performed in a transparent polyacrylamide gel resembling soft tissue. Mechanical effects, changes in temperature gradient, and absolute temperature changes were measured with three different optical techniques (high-speed, color Schlieren, and infrared imaging) to investigate the effect on temperature of variations in voltage, pulse length, active tip length (ATL), interelectrode distance, electrode configuration (parallel, convergent, and divergent), and sequential pulsing (pulse delivery interrupted by breaks). The total delivered energy was calculated. RESULTS: A temperature gradient, starting at the tips of both electrodes and expanding toward each other, developed immediately with pulse delivery. Temperatures increased with increasing voltage (by 2.5°C-40.4°C), pulse length (by 5.3°C-9.8°C), ATL (by 5.9°C-17.6°C), and interelectrode distance (by 7.6°C-21.5°C), in accordance with higher energy delivery. Nonparallel electrode placement resulted in heterogeneous temperature distribution with the peak temperature focused in the area with the shortest interelectrode distance. Sequential pulse delivery significantly reduced the temperature increase compared with continuous pulsing (4.3°C vs 11.7°C). CONCLUSIONS: Voltage, pulse length, interelectrode distance, ATL, and electrode configuration each have a strong effect on temperature development and distribution during IRE. Sequential pulsing reduces the extent and volume of thermal distribution and may prove beneficial with respect to procedural safety.


Assuntos
Técnicas de Ablação , Resinas Acrílicas/química , Eletroporação , Temperatura Alta , Condutividade Elétrica , Transferência de Energia , Gases , Modelos Anatômicos , Termografia , Fatores de Tempo , Gravação em Vídeo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA