Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Trop Med Infect Dis ; 9(7)2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-39058193

RESUMO

Lyssaviruses are neurotropic viruses capable of inducing fatal encephalitis. While rabies virus has been successfully eradicated in Belgium, the prevalence of other lyssaviruses remains uncertain. In this study, we conducted a survey on live animals and passive surveillance to investigate the presence of lyssaviruses in Belgium. In 2018, a total of 113 saliva samples and 87 blood samples were collected from bats. Saliva was subjected to RT-qPCR to identify lyssavirus infections. Additionally, an adapted lyssavirus neutralisation assay was set up for the detection of antibodies neutralising EBLV-1 in blood samples. Furthermore, we examined 124 brain tissue samples obtained from deceased bats during passive surveillance between 2016 and 2018. All saliva samples tested negative for lyssaviruses. Analysis of the blood samples uncovered the presence of lyssavirus-neutralising antibodies in five bat species and 32% of samples with a wide range depending on bat species, suggesting past exposure to a lyssavirus. Notably, EBLV-1 was detected in brain tissue samples from two Eptesicus serotinus specimens collected in 2016 near Bertrix and 2017 near Étalle, confirming for the first time the presence of EBLV-1 in Belgium and raising awareness of the potential risks associated with this species of bats as reservoirs of the virus.

2.
Microbiol Spectr ; 12(2): e0239723, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38189291

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic demonstrated the need for accurate diagnostic testing for the early detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Although the pandemic has ended, accurate assays are still needed to monitor viral spread at national levels and beyond through population and wastewater surveillance. To enhance early detection, SARS-CoV-2 assays should have high diagnostic accuracy and should be validated to assure accurate results. Three distinct SARS-CoV-2 assays were evaluated with clinical samples using the VALCOR (VALidation of SARS-CORona Virus-2 assays) framework, with the TaqPath COVID-19 assay (ThermoFisher Scientific, USA) as a comparator. We evaluated clinical sensitivity, specificity, limit of detection (LOD), and overall concordance between comparator and three index Allplex SARS-CoV-2 assays (Seegene, South Korea): Allplex-SC2, Allplex-SC2Fast (Fast PCR), and Allplex-SC2FabR (SARS-CoV-2/FluA/FluB/respiratory syncytial virus). Analytical performance and LOD of index assays were assessed using a dilution series of three synthetic SARS-CoV-2 sequence reference materials (RMs). Ninety SARS-CoV-2 positives and 90 SARS-CoV-2 negatives were tested. All Allplex assays had 100.0% sensitivity (95%CI = 95.9%-100.0%). Allplex-SC2 and Allplex-SC2Fast assays had 97.8% specificity (95%CI = 92.3%-99.7%) and 98.9% overall concordance [κ = 0.978 (95%CI = 0.947-1.000)]. Allplex-SC2FabR assay showed 100.0% specificity (95%CI = 95.9%-100.0%) and 100.0% overall concordance [κ = 1.000 (95%CI = 1.000-1.000)]. LOD assessment of index assays revealed detection down to 2.61 × 102 copies/mL in clinical samples, while the analytical LOD was 9.00 × 102 copies/mL. In conclusion, the evaluation of the three Seegene Allplex SARS-CoV-2 assays showed high sensitivity and specificity and an overall good assay concordance with the comparator. The assays showed low analytical LOD using RM and even a slightly lower LOD in clinical samples. Non-overlapping target gene sequences between SARS-CoV-2 assays and RMs emphasize the need for aligning targeted sequences of diagnostic assays and RMs.IMPORTANCEThe coronavirus disease 2019 pandemic has a significant impact on global public health, economies, and societies. As shown through the first phases of the pandemic, accurate and timely diagnosis is crucial for disease control, prevention, and monitoring. Though the pandemic phase of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has concluded, diagnostic assays remain in demand to monitor SARS-CoV-2 at the individual patient level, regionally, and nationally, as well as to remain an infectious disease preparedness instrument to monitor any new SARS-CoV-2 dissemination across borders using population and wastewater surveillance. The anticipation by WHO and central health care policy entities such as the Center for Disease Control, EMA, and multiple national health authorities is that SARS-CoV-2 will reside as an endemic respiratory disease for years to come. The key strategic consideration is hence shifting from combating a pandemic situation with a high number of patients to instead allowing precise diagnostics of suspected patients with the intention of correct management in a low-prevalence setting.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Águas Residuárias , Sensibilidade e Especificidade , Vigilância Epidemiológica Baseada em Águas Residuárias
3.
J Clin Virol ; 171: 105657, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38401369

RESUMO

BACKGROUND: Some high-grade cervical lesions and cervical cancers (HSIL+) test negative for human papillomavirus (HPV). The HPV-negative fraction varies between 0.03 % and 15 % between different laboratories. Monitoring and extended re-analysis of HPV-negative HSIL+ could thus be helpful to monitor performance of HPV testing services. We aimed to a) provide a real-life example of a quality assurance (QA) program based on re-analysis of HPV-negative HSIL+ and b) develop international guidance for QA of HPV testing services based on standardized identification of apparently HPV-negative HSIL+ and extended re-analysis, either by the primary laboratory or by a national HPV reference laboratory (NRL). METHODS: There were 116 initially HPV-negative cervical specimens (31 histopathology specimens and 85 liquid-based cytology samples) sent to the Swedish HPV Reference Laboratory for re-testing. Based on the results, an international QA guidance was developed through an iterative consensus process. RESULT: Standard PCR testing detected HPV in 55.2 % (64/116) of initially "HPV-negative" samples. Whole genome sequencing of PCR-negative samples identified HPV in an additional 7 samples (overall 61.2 % HPV positivity). Reasons for failure to detect HPV in an HSIL+ lesion are listed and guidance to identify cases for extended re-testing, including which information should be included when referring samples to an NRL are presented. CONCLUSION: Monitoring the proportion of and reasons for failure to detect HPV in HSIL+ will help support high performance and quality improvement of HPV testing services. We encourage implementation of QA strategies based on re-analysis of "HPV negative" HSIL+ samples.


Assuntos
Infecções por Papillomavirus , Displasia do Colo do Útero , Neoplasias do Colo do Útero , Feminino , Humanos , Displasia do Colo do Útero/diagnóstico , Papillomavirus Humano , Infecções por Papillomavirus/diagnóstico , Programas de Rastreamento/métodos , Papillomaviridae/genética
4.
Vet Sci ; 10(12)2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38133227

RESUMO

Hepatitis E virus is a prominent cause of viral hepatitis worldwide. In Western countries, most infections are asymptomatic. However, acute self-limiting hepatitis and chronic cases in immunocompromised individuals can occur. Studying HEV is challenging due to its difficulty to grow in cell culture. Consequently, the detection of the virus mainly relies on RT-qPCR, which cannot differentiate between infectious and non-infectious particles. To overcome this problem, methods assessing viral integrity offer a possible solution to differentiate between intact and damaged viruses. This study aims at optimizing existing HEV cell culture models and RT-qPCR-based assays for selectively detecting intact virions to establish a reliable model for assessing HEV infectivity. In conclusion, these newly developed methods hold promise for enhancing food safety by identifying approaches for inactivating HEV in food processing, thereby increasing food safety measures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA