RESUMO
OBJECTIVES: The aim of this study was to assess the predictive value of PMA measurement for mortality. BACKGROUND: Current surgical risk stratification have limited predictive value in the transcatheter aortic valve implantation (TAVI) population. In TAVI workup, a CT scan is routinely performed but body composition is not analyzed. Psoas muscle area (PMA) reflects a patient's global muscle mass and accordingly PMA might serve as a quantifiable frailty measure. METHODS: Multi-slice computed tomography scans (between 2010 and 2016) of 583 consecutive TAVI patients were reviewed. Patients were divided into equal sex-specific tertiles (low, mid, and high) according to an indexed PMA. Hazard ratios (HR) and their confidence intervals (CI) were determined for cardiac and all-cause mortality after TAVI. RESULTS: Low iPMA was associated with cardiac and all-cause mortality in females. One-year adjusted cardiac mortality HR in females for mid-iPMA and high-iPMA were 0.14 [95%CI, 0.05-0.45] and 0.40 [95%CI, 0.15-0.97], respectively. Similar effects were observed for 30-day and 2-years cardiac and all-cause mortality. In females, adding iPMA to surgical risk scores improved the predictive value for 1-year mortality. C-statistics changed from 0.63 [CI = 0.54-0.73] to 0.67 [CI: 0.58-0.75] for EuroSCORE II and from 0.67 [CI: 0.59-0.77] to 0.72 [CI: 0.63-0.80] for STS-PROM. CONCLUSIONS: Particularly in females, low iPMA is independently associated with an higher all-cause and cardiac mortality. Prospective studies should confirm whether PMA or other body composition parameters should be extracted automatically from CT-scans to include in clinical decision making and outcome prediction for TAVI.
Assuntos
Estenose da Valva Aórtica/cirurgia , Composição Corporal , Fragilidade/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Músculos Psoas/diagnóstico por imagem , Sarcopenia/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Fragilidade/mortalidade , Fragilidade/fisiopatologia , Nível de Saúde , Humanos , Masculino , Valor Preditivo dos Testes , Músculos Psoas/fisiopatologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sarcopenia/mortalidade , Sarcopenia/fisiopatologia , Fatores Sexuais , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
BACKGROUND: There is an increasing trend towards shorter hospital stays after transcatheter aortic valve implantation (TAVI), in particular for patients undergoing the procedure via transfemoral (TF) access. Preliminary data suggest that there exists a population of patients that can be discharged safely very early after TF-TAVI. However, current evidence is limited to few retrospective studies, encompassing relatively small sample sizes. METHODS: The Feasibility And Safety of early discharge after Transfemoral TAVI (FAST-TAVI) registry is a prospective observational registry that will be conducted at 10 sites across Italy, the Netherlands and the UK. Patients will be included if they have been scheduled to undergo TF-TAVI with the balloon-expandable SAPIEN 3 transcatheter heart valve (THV; Edwards Lifesciences, Irvine, CA). The primary endpoint is a composite of all-cause mortality, vascular-access-related complications, permanent pacemaker implantation, stroke, re-hospitalisation due to cardiac reasons, kidney failure and major bleeding, occurring during the first 30 days after hospital discharge. Patients will be stratified according to whether they were high or low risk for early discharge (≤3 days) (following pre-specified criteria), and according to whether or not they were discharged early. Secondary endpoints will include time-to-event (Kaplan-Meier) analysis for the primary outcome and its individual components, analysis of the relative costs of early and late discharge, and changes in short- and long-term quality of life. Multivariate logistic regression will be used to identify factors that indicate that a patient may be suitable for early discharge. DISCUSSION: The data gathered in the FAST-TAVI registry should help to clarify the safety of early discharge after TF-TAVI and to identify patient and procedural characteristics that make early discharge from hospital a safe and cost-effective strategy. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02404467 (registration first received March 23rd 2015).
Assuntos
Artéria Femoral/cirurgia , Alta do Paciente/normas , Complicações Pós-Operatórias/prevenção & controle , Sistema de Registros/normas , Substituição da Valva Aórtica Transcateter/normas , Estudos de Viabilidade , Humanos , Itália/epidemiologia , Países Baixos/epidemiologia , Alta do Paciente/tendências , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/tendências , Reino Unido/epidemiologiaRESUMO
BACKGROUND: Decreasing the amount of iodinated contrast is an important safety aspect of percutaneous coronary interventions (PCI), particularly in patients with a high risk of contrast-induced acute kidney injury (CI-AKI). Dynamic Coronary Roadmap (DCR) is a PCI navigation support tool projecting a motion-compensated virtual coronary roadmap overlay on fluoroscopy, potentially limiting the need for contrast during PCI. AIMS: This study investigates the contrast-sparing potential of DCR in PCI, compared to standard angiographic guidance. METHODS: The Dynamic Coronary Roadmap for Contrast Reduction (DCR4Contrast) trial is a multicentre, international, prospective, unblinded, stratified 1:1 randomised controlled trial. Patients were randomised to either DCR-guided PCI or to conventional angiography-guided PCI. The primary endpoint was the total volume of iodinated contrast administered, and the secondary endpoint was the number of cineangiography runs during PCI. RESULTS: The study population included 356 randomised patients (179 in DCR and 177 in control groups, respectively). There were no differences in patient demographics, angiographic characteristics or estimated glomerular filtration rate (eGFR) between the two groups. The total contrast volume used during PCI was significantly lower with DCR guidance compared with conventional angiographic guidance (64.6±44.4 ml vs 90.8±55.4 ml, respectively; p<0.001). The total number of cineangiography runs was also significantly reduced in the DCR group (8.7±4.7 vs 11.7±7.6 in the control group; p<0.001). CONCLUSIONS: Compared to conventional angiography-guided PCI, DCR guidance was associated with a significant reduction in both contrast volume and the number of cineangiography runs during PCI. (ClinicalTrials.gov: NCT04085614).
Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Meios de Contraste/efeitos adversosRESUMO
BACKGROUND & AIMS: Accurate diagnosis of sarcopenia requires evaluation of muscle quality, which refers to the amount of fat infiltration in muscle tissue. In this study, we aim to investigate whether we can independently predict mortality risk in transcatheter aortic valve implantation (TAVI) patients, using automatic deep learning algorithms to assess muscle quality on procedural computed tomography (CT) scans. METHODS: This study included 1199 patients with severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI) between January 2010 and January 2020. A procedural CT scan was performed as part of the preprocedural-TAVI evaluation, and the scans were analyzed using deep-learning-based software to automatically determine skeletal muscle density (SMD) and intermuscular adipose tissue (IMAT). The association of SMD and IMAT with all-cause mortality was analyzed using a Cox regression model, adjusted for other known mortality predictors, including muscle mass. RESULTS: The mean age of the participants was 80 ± 7 years, 53% were female. The median observation time was 1084 days, and the overall mortality rate was 39%. We found that the lowest tertile of muscle quality, as determined by SMD, was associated with an increased risk of mortality (HR 1.40 [95%CI: 1.15-1.70], p < 0.01). Similarly, low muscle quality as defined by high IMAT in the lowest tertile was also associated with increased mortality risk (HR 1.24 [95%CI: 1.01-1.52], p = 0.04). CONCLUSIONS: Our findings suggest that deep learning-assessed low muscle quality, as indicated by fat infiltration in muscle tissue, is a practical, useful and independent predictor of mortality after TAVI.
Assuntos
Estenose da Valva Aórtica , Aprendizado Profundo , Músculo Esquelético , Sarcopenia , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Masculino , Idoso de 80 Anos ou mais , Idoso , Sarcopenia/diagnóstico por imagem , Sarcopenia/mortalidade , Músculo Esquelético/diagnóstico por imagem , Tecido Adiposo/diagnóstico por imagem , Fatores de Risco , Estudos Retrospectivos , Valor Preditivo dos TestesRESUMO
PURPOSE: We assessed the accuracy of a new 3D2D registration algorithm to be used for navigated spine surgery and explored anatomical and radiologic parameters affecting the registration accuracy. Compared to existing 3D2D registration algorithms, the algorithm does not need bone-mounted or table-mounted instruments for registration. Neither does the intraoperative imaging device have to be tracked or calibrated. METHODS: The rigid registration algorithm required imaging data (a pre-existing CT scan (3D) and two angulated fluoroscopic images (2D)) to register positions of vertebrae in 3D and is based on non-invasive skin markers. The algorithm registered five adjacent vertebrae and was tested in the thoracic and lumbar spine from three human cadaveric specimens. The registration accuracy was calculated for each registered vertebra and measured with the target registration error (TRE) in millimeters. We used multivariable analysis to identify parameters independently affecting the algorithm's accuracy such as the angulation between the two fluoroscopic images (between 40° and 90°), the detector-skin distance, the number of skin markers applied, and waist circumference. RESULTS: The algorithm registered 780 vertebrae with a median TRE of 0.51 mm [interquartile range 0.32-0.73 mm] and a maximum TRE of 2.06 mm. The TRE was most affected by the angulation between the two fluoroscopic images obtained (p < 0.001): larger angulations resulted in higher accuracy. The algorithm was more accurate in thoracic vertebrae (p = 0.004) and in the specimen with the smallest waist circumference (p = 0.003). The algorithm registered all five adjacent vertebrae with similar accuracy. CONCLUSION: We studied the accuracy of a new 3D2D registration algorithm based on non-invasive skin markers. The algorithm registered five adjacent vertebrae with similar accuracy in the thoracic and lumbar spine and showed a maximum target registration error of approximately 2 mm. To further evaluate its potential for navigated spine surgery, the algorithm may now be integrated into a complete navigation system.
Assuntos
Cirurgia Assistida por Computador , Algoritmos , Fluoroscopia/métodos , Humanos , Imageamento Tridimensional/métodos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/cirurgiaRESUMO
Background: Manual muscle mass assessment based on Computed Tomography (CT) scans is recognized as a good marker for malnutrition, sarcopenia, and adverse outcomes. However, manual muscle mass analysis is cumbersome and time consuming. An accurate fully automated method is needed. In this study, we evaluate if manual psoas annotation can be substituted by a fully automatic deep learning-based method. Methods: This study included a cohort of 583 patients with severe aortic valve stenosis planned to undergo Transcatheter Aortic Valve Replacement (TAVR). Psoas muscle area was annotated manually on the CT scan at the height of lumbar vertebra 3 (L3). The deep learning-based method mimics this approach by first determining the L3 level and subsequently segmenting the psoas at that level. The fully automatic approach was evaluated as well as segmentation and slice selection, using average bias 95% limits of agreement, Intraclass Correlation Coefficient (ICC) and within-subject Coefficient of Variation (CV). To evaluate performance of the slice selection visual inspection was performed. To evaluate segmentation Dice index was computed between the manual and automatic segmentations (0 = no overlap, 1 = perfect overlap). Results: Included patients had a mean age of 81 ± 6 and 45% was female. The fully automatic method showed a bias and limits of agreement of -0.69 [-6.60 to 5.23] cm2, an ICC of 0.78 [95% CI: 0.74-0.82] and a within-subject CV of 11.2% [95% CI: 10.2-12.2]. For slice selection, 84% of the selections were on the same vertebra between methods, bias and limits of agreement was 3.4 [-24.5 to 31.4] mm. The Dice index for segmentation was 0.93 ± 0.04, bias and limits of agreement was -0.55 [1.71-2.80] cm2. Conclusion: Fully automatic assessment of psoas muscle area demonstrates accurate performance at the L3 level in CT images. It is a reliable tool that offers great opportunities for analysis in large scale studies and in clinical applications.
RESUMO
Background: TAVI has shown to result in immediate and sustained hemodynamic alterations and improvement in health-related quality of life (HRQoL), but previous studies have been suboptimal to predict who might benefit from TAVI. The relationship between immediate hemodynamic changes and outcome has not been studied before. This study sought to assess whether an immediate hemodynamic change, reflecting myocardial contractile reserve, following TAVI is associated with improved HRQoL. Furthermore, it assessed whether pre-procedural cardiac power index (CPI) and left ventricular ejection fraction (LVEF) could predict these changes. Methods: During the TAVI procedure, blood pressure and systemic hemodynamics were prospectively collected with a Nexfin® non-invasive monitor. HRQoL was evaluated pre-procedurally and 12 weeks after the procedure, using the EQ-5D-5L classification tool. Results: Overall, 97/114 (85%) of the included patients were eligible for analyses. Systolic, diastolic and mean arterial pressure, heart rate, and stroke volume increased immediately after TAVI (all p < 0.005), and left ventricular ejection time (LVET) immediately decreased with 10 ms (95%CI = -4 to -16, p < 0.001). Overall HRQoLindex increased from 0.810 [0.662-0.914] before to 0.887 [0.718-0.953] after TAVI (p = 0.016). An immediate decrease in LVET was associated with an increase in HRQoLindex (0.02 index points per 10 ms LVET decrease, p = 0.041). Pre-procedural CPI and LVEF did not predict hemodynamic changes or change in HRQoL. Conclusion: TAVI resulted in an immediate hemodynamic response and increase in HRQoL. Immediate reduction in LVET, suggesting unloading of the ventricle, was associated with an increase in HRQoL, but neither pre-procedural CPI nor LVEF predicted these changes. Clinical trial registration: https://clinicaltrials.gov/ct2/show/NCT03088787.
RESUMO
Current prognostic risk scores for transcatheter aortic valve implantation (TAVI) do not benefit yet from modern machine learning techniques, which can improve risk stratification of one-year mortality of patients before TAVI. Despite the advancement of machine learning in healthcare, data sharing regulations are very strict and typically prevent exchanging patient data, without the involvement of ethical committees. A very robust validation approach, including 1300 and 631 patients per center, was performed to validate a machine learning model of one center at the other external center with their data, in a mutual fashion. This was achieved without any data exchange but solely by exchanging the models and the data processing pipelines. A dedicated exchange protocol was designed to evaluate and quantify the model's robustness on the data of the external center. Models developed with the larger dataset offered similar or higher prediction accuracy on the external validation. Logistic regression, random forest and CatBoost lead to areas under curve of the ROC of 0.65, 0.67 and 0.65 for the internal validation and of 0.62, 0.66, 0.68 for the external validation, respectively. We propose a scalable exchange protocol which can be further extended on other TAVI centers, but more generally to any other clinical scenario, that could benefit from this validation approach.
RESUMO
Background: Machine learning models have been developed for numerous medical prognostic purposes. These models are commonly developed using data from single centers or regional registries. Including data from multiple centers improves robustness and accuracy of prognostic models. However, data sharing between multiple centers is complex, mainly because of regulations and patient privacy issues. Objective: We aim to overcome data sharing impediments by using distributed ML and local learning followed by model integration. We applied these techniques to develop 1-year TAVI mortality estimation models with data from two centers without sharing any data. Methods: A distributed ML technique and local learning followed by model integration was used to develop models to predict 1-year mortality after TAVI. We included two populations with 1,160 (Center A) and 631 (Center B) patients. Five traditional ML algorithms were implemented. The results were compared to models created individually on each center. Results: The combined learning techniques outperformed the mono-center models. For center A, the combined local XGBoost achieved an AUC of 0.67 (compared to a mono-center AUC of 0.65) and, for center B, a distributed neural network achieved an AUC of 0.68 (compared to a mono-center AUC of 0.64). Conclusion: This study shows that distributed ML and combined local models techniques, can overcome data sharing limitations and result in more accurate models for TAVI mortality estimation. We have shown improved prognostic accuracy for both centers and can also be used as an alternative to overcome the problem of limited amounts of data when creating prognostic models.
RESUMO
OBJECTIVES: To analyze the effect of percutaneous coronary intervention (PCI) before transcatheter aortic valve replacement (TAVR) on all-cause and cardiovascular mortality after TAVR, differentiating between significant proximal lesions and the non-proximal (residual) lesions. METHODS: An institutional TAVR database was complemented with data on the extent of coronary artery disease (CAD), lesion location, lesion severity, and the location of PCI. Survival analysis was performed to investigate the impact on 6-month and 3-year mortality after TAVR in all patients and in subgroups of patients with significant proximal lesions (>70% diameter stenosis [DS], >50% DS in left main), the non-proximal residual lesions, and in a propensity score matched cohort. RESULTS: Among the 577 included patients, mean age was 83 years, 50% were female, and 31% had diabetes mellitus. Preprocedural PCI of unselected lesions was independently associated with increased 6-month mortality (hazard ratio, 2.2; 95% confidence interval, 1.0-4.6; P=.04), but selective PCI of significant proximal lesions did not have an association with higher mortality, nor did we find a significant effect of PCI on mortality in the propensity-matched cohort. CONCLUSION: Routine pre-TAVR PCI is not associated with mortality reduction in TAVR patients with coronary lesions in any segment or in patients with proximal coronary lesions. Despite the lack of a beneficial effect of routine pre-TAVR PCI, we cannot exclude a beneficial effect in a selection of patients with proximal lesions. Therefore, we strongly support the current clinical guidelines to only consider pre-TAVR PCI in proximal coronary lesions, while advocating a restrictive pre-TAVR PCI strategy.
Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
BACKGROUND: The timing of onset and associated predictors of late new conduction disturbances (CDs) leading to permanent pacemaker implantation (PPI) following transcatheter aortic valve implantation (TAVI) are still unknown, however, essential for an early and safe discharge. This study aimed to investigate the timing of onset and associated predictors of late onset CDs in patients requiring PPI (LCP) following TAVI. METHODS AND RESULTS: We performed retrospective analysis of prospectively collected data from five large volume centres in Europe. Post-TAVI electrocardiograms and telemetry data were evaluated in patients with a PPI post-TAVI to identify the onset of new advanced CDs. Early onset CDs were defined as within 48 hours after procedure, and late onset CDs as after 48 hours. A total of 2804 patients were included for analysis. The PPI rate was 12%, of which 18% was due to late onset CDs (>48 hours). Independent predictors for LCP were pre-existing non-specific intraventricular conduction delay, pre-existing right bundle branch block, self-expandable valves and predilation. At least one of these risk factors was present in 98% of patients with LCP. Patients with a balloon-expandable valve without predilation did not develop CDs requiring PPI after 48 hours. CONCLUSIONS: Safe early discharge might be feasible in patients without CDs in the first 48 hours after TAVI if no risk factors for LCP are present.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/mortalidade , Bases de Dados Factuais , Europa (Continente) , Feminino , Humanos , Tempo de Internação , Masculino , Alta do Paciente , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do TratamentoRESUMO
Background Despite the availability of guidelines for the performance of transcatheter aortic valve implantation (TAVI), current treatment pathways vary between countries and institutions, which impact on the mean duration of postprocedure hospitalization. Methods and Results This was a prospective, multicenter registry of 502 patients to validate the appropriateness of discharge timing after transfemoral TAVI, using prespecified risk criteria from FAST-TAVI (Feasibility and Safety of Early Discharge After Transfemoral [TF] Transcatheter Aortic Valve Implantation), based on hospital events within 1-year after discharge. The end point-a composite of all-cause mortality, vascular access-related complications, permanent pacemaker implantation, stroke, cardiac rehospitalization, kidney failure, and major bleeding-was reached in 27.0% of patients (95% CI, 23.3-31.2) within 1 year after intervention; 7.5% (95% CI, 5.5-10.2) had in-hospital complications before discharge and 19.6% (95% CI, 16.3-23.4) within 1 year after discharge. Overall mortality within 1 year after discharge was 7.3% and rates of cardiac rehospitalization 13.5%, permanent pacemaker implantation 4.2%, any stroke 1.8%, vascular-access-related complications 0.7%, life-threatening bleeding 0.7%, and kidney failure 0.4%. Composite events within 1 year after discharge were observed in 18.8% and 24.3% of patients with low risk of complications/early (≤3 days) discharge and high risk and discharged late (>3 days) (concordant discharge), respectively. Event rate in patients with discordant discharge was 14.3% with low risk but discharged late and increased to 50.0% in patients with high risk but discharged in ≤3 days. Conclusions The FAST-TAVI risk assessment provides a tool for appropriate, risk-based discharge that was validated with the 1-year event rate after transfemoral TAVI. Registration URL: https://www.ClinicalTrials.gov; Unique identifier: NCT02404467.
Assuntos
Alta do Paciente , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Europa (Continente)/epidemiologia , Humanos , Estudos ProspectivosRESUMO
OBJECTIVES: The aim of this study was to assess acute regurgitation following transcatheter aortic valve replacement, comparing different implanted transcatheter heart valves. BACKGROUND: Regurgitation following transcatheter aortic valve replacement influences all-cause mortality. Thus far, no quantitative comparison of regurgitation among multiple commercially available transcatheter heart valves has been performed. METHODS: Aortograms from a multicenter cohort of consecutive 3,976 transcatheter aortic valve replacements were evaluated in this pooled analysis. A total of 2,258 (58.3%) were considered analyzable by an independent academic core laboratory using video densitometry. Results of quantitative regurgitation are shown as percentages. The valves evaluated were the ACURATE (n = 115), Centera (n = 11), CoreValve (n = 532), Direct Flow Medical (n = 21), Evolut PRO (n = 95), Evolut R (n = 295), Inovare (n = 4), Lotus (n = 546), Lotus Edge (n = 3), SAPIEN XT (n = 239), and SAPIEN 3 (n = 397). For the main analysis, only valves with more than 50 procedures (7 types) were used. RESULTS: The Lotus valve had the lowest mean regurgitation (3.5 ± 4.4%), followed by Evolut PRO (7.4 ± 6.5%), SAPIEN 3 (7.6 ± 7.1%), Evolut R (7.9 ± 7.4%), SAPIEN XT (8.8 ± 7.5%), ACURATE (9.6 ± 9.2%) and CoreValve (13.7 ± 10.7%) (analysis of variance p < 0.001). The only valves that statistically differed from all their counterparts were Lotus (as the lowest regurgitation) and CoreValve (the highest). The proportion of patients presenting with moderate or severe regurgitation followed the same ranking order: Lotus (2.2%), Evolut PRO (5.3%), SAPIEN 3 (8.3%), Evolut R (8.8%), SAPIEN XT (10.9%), ACURATE (11.3%), and CoreValve (30.1%) (chi-square p < 0.001). CONCLUSIONS: In this pooled analysis stemming from daily clinical practice, the Lotus valve was shown to have the best immediate sealing. This analysis reflects the objective evaluation of regurgitation by an academic core laboratory (nonsponsored) in a real-world cohort of patients using a quantitative technique.
Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Resultado do TratamentoRESUMO
In recent years, transcatheter aortic valve implantation (TAVI) has evolved from a treatment for patients who are inoperable or at high risk of surgical complications, to an equivalent alternative to surgical valve replacement for almost all patients with symptomatic, severe aortic valve stenosis. In the Netherlands, the number of patients who undergo TAVI gradually increases, while outcomes after TAVI improve and complication rates decrease. Before TAVI can be considered as the preferred treatment for aortic valve stenosis, however, additional insight is needed in valve durability, selection criteria for patients who benefit most from TAVI, and treatment outcomes regarding quality of life.
Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Ensaios Clínicos como Assunto , Humanos , Países Baixos , Avaliação de Resultados da Assistência ao Paciente , Seleção de Pacientes , Qualidade de Vida , Substituição da Valva Aórtica Transcateter/tendênciasRESUMO
AIMS: Treatment pathway optimisation in TAVI should include timely patient discharge with a minimised risk for out-of-hospital adverse events. The aim of this study was to define a standardised set of risk criteria that allows a safe and timely discharge, to validate their appropriateness prospectively in different centres and multiple European countries, and to assess post-discharge outcomes. METHODS AND RESULTS: We defined and validated the adequacy of a set of discharge criteria and its ability to predict timely and safe discharge properly after the intervention in a prospective, European, multicentre registry. A total of 502 unselected patients were enrolled at 10 sites in three countries. The primary endpoint, defined as a composite of all-cause mortality, vascular access-related complications, permanent pacemaker implantation, stroke, re-hospitalisation due to cardiac reasons, kidney failure and major bleeding at 30 days, was reached in 12.9% of patients (95% CI: 11.3-16.5). The overall 30-day mortality was 1.1% (95% CI: 0.2-2.0), and the rates of stroke/TIA 1.7% (95% CI: -0.6 to 4.0), PPI 7.3% (95% CI: 5.8-8.9), major vascular complications 1.9% (95% CI: 0.7-3.1), major/life-threatening bleeding 2.4% (95% CI: 1.0-3.8) and cardiac re-hospitalisation 3.7% (95% CI: 1.4-6.0). Patients appropriately discharged early had a significantly lower risk of the primary endpoint (7.0 vs. 26.4%; p<0.001) which was reflected in some of its relevant components: stroke (0.0 vs. 2.8%; p=0.015), PPI (4.3 vs. 15.9%; p<0.001), major vascular complications (0.3 vs. 4.7%; p=0.004) and major/life-threatening bleeding (0.3 vs. 6.5%; p<0.001). CONCLUSIONS: We validated the appropriateness of a pre-specified set of risk criteria that allows a safe and timely discharge. The rate of 30-day complications did not reveal any risk increase with this strategy compared with the reported outcomes in major TAVI trials and registries. ClinicalTrials.gov Identifier: NCT02404467.
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica , Europa (Continente) , Humanos , Alta do Paciente , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Resultado do TratamentoRESUMO
BACKGROUND: In a three-month report from the CGA-TAVI registry, we found the Multidimensional Prognostic Index (MPI) and Short Physical Performance Battery (SPPB) to be of value for predicting short-term outcomes in elderly patients undergoing transcatheter aortic valve implantation (TAVI). In the present analysis, we examined the association of these tools with outcomes up to one year post-TAVI. METHODS: CGA-TAVI is an international, observational registry of geriatric patients undergoing TAVI. Patients were assessed using the MPI and SPPB. Efficacy of baseline values and any postoperative change for predicting outcome were established using logistic regression. Kaplan-Meier analysis was carried out for each comprehensive geriatric assessment tool, with survival stratified by risk category. RESULTS: One year after TAVI, 14.1% of patients deceased, while 17.4% met the combined endpoint of death and/or non-fatal stroke, and 37.7% the combined endpoint of death and/or hospitalisation and/or non-fatal stroke. A high-risk MPI score was associated with an increased risk of all-cause mortality (aOR = 36.13, 95% CI: 2.77-470.78, P = 0.006) and death and/or non-fatal stroke (aOR = 10.10, 95% CI: 1.48-68.75, P = 0.018). No significant associations were found between a high-risk SPPB score and mortality or two main combined endpoints. In contrast to a worsening SPPB, an aggravating MPI score at three months post-TAVI was associated with an increased risk of death and/or non-fatal stoke at one year (aOR = 95.16, 95% CI: 3.41-2657.01). CONCLUSIONS: The MPI showed value for predicting the likelihood of death and a combination of death and/or non-fatal stroke by one year after TAVI in elderly patients.
RESUMO
BACKGROUND: The postprocedural trajectory of patients undergoing transcatheter aortic valve replacement (TAVR) involves in-hospital monitoring of potential cardiac rhythm or conduction disorders and other complications. Recent advances in telemonitoring technologies create opportunities to monitor electrocardiogram (ECG) and vital signs remotely, facilitating redesign of follow-up trajectories. OBJECTIVE: This study aimed to outline a potential set-up of telemonitoring after TAVR. METHODS: A multidisciplinary team systematically framed the envisioned telemonitoring scenario according to the intentions, People, Activities, Context, Technology (iPACT) and Functionality, Interaction, Content, Services (FICS) methods and identified corresponding technical requirements. RESULTS: In this scenario, a wearable sensor system is used to continuously transmit ECG and contextual data to a central monitoring unit, allowing remote follow-up of ECG abnormalities and physical deteriorations. Telemonitoring is suggested as an alternative or supplement to current in-hospital monitoring after TAVR, enabling early hospital dismissal in eligible patients and accessible follow-up prolongation. Together, this approach aims to improve rehabilitation, enhance patient comfort, optimize hospital capacity usage, and reduce overall costs. Required technical components include continuous data acquisition, real-time data transfer, privacy-ensured storage, automatic event detection, and user-friendly interfaces. CONCLUSIONS: The suggested telemonitoring set-up involves a new approach to patient follow-up that could bring durable solutions for the growing scarcities in health care and for improving health care quality. To further explore the potential and feasibility of post-TAVR telemonitoring, we recommend evaluation of the overall impact on patient outcomes and of the safety, social, ethical, legal, organizational, and financial factors.
RESUMO
In patients who underwent transcatheter aortic valve implantation (TAVI), postoperative mortality risk is commonly assessed with risk scores such as the Society of Thoracic Surgeons-Postoperative Risk of Mortality (STS-PROM) and EuroSCORE II, in which age plays a dominant role. However, we reason that in the naturally selected oldest-old patients (nonagenarians), this may not be completely justified and that therefore age should play a minor role in decision-making. The objective of this study was to compare procedural outcome and mid-term mortality of transfemoral (TF)-TAVI patients aged ≥90 years with patients aged <90 years. In this single-center analysis of 599 prospectively acquired consecutive TF-TAVI patients between 2009 and 2017, we compared patients aged ≥90 (i.e., nonagenarians, n = 47) with patients aged <90 years (n = 552), using Kaplan-Meyer analysis and multivariate logistic regression. In the nonagenarians, we found more aortic regurgitation, moderate to severe paravalvular leakage, strokes and vascular complications, and less device success and bleeding complications compared with patients <90 years. Both groups showed similar symptomatic improvement. The predicted (STS-PROM) and actual procedural mortality were 8.033% and 2.1% (3.8×) and 4.868% and 1.8% (2.7×) for the nonagenarians and controls, respectively. Survival was not statistically different at the 1-, 2-, 3-, 4-, and 5-year mark. In conclusion, nonagenarians had similar symptomatic improvement and acceptable procedural outcome and mid-term survival to TF-TAVI patients aged <90 years. Thus, age is not a risk factor in predicting postoperative outcome and mortality and therefore should not be a reason to deny the oldest-old patient transfemoral TAVI.
Assuntos
Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Hemorragia Pós-Operatória/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Mortalidade Hospitalar , Humanos , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Complicações Pós-Operatórias/epidemiologia , Modelos de Riscos Proporcionais , Resultado do TratamentoRESUMO
BACKGROUND: Infective endocarditis (IE) after transcatheter pulmonary valve implantation (TPVI) in dysfunctioning right ventricular outflow tract conduits has evoked growing concerns. We aimed to investigate the incidence and the natural history of IE after TPVI with the Melody valve through a systematic review of published data. METHODS AND RESULTS: PubMed, EMBASE, and Web of Science databases were systematically searched for articles published until March 2017, reporting on IE after TPVI with the Melody valve. Nine studies (including 851 patients and 2060 patient-years of follow-up) were included in the analysis of the incidence of IE. The cumulative incidence of IE ranged from 3.2% to 25.0%, whereas the annualized incidence rate ranged from 1.3% to 9.1% per patient-year. The median (interquartile range) time from TPVI to the onset of IE was 18.0 (9.0-30.4) months (range, 1.0-72.0 months). The most common findings were positive blood culture (93%), fever (89%), and new, significant, and/or progressive right ventricular outflow tract obstruction (79%); vegetations were detectable on echocardiography in only 34% of cases. Of 69 patients with IE after TPVI, 6 (8.7%) died and 35 (52%) underwent surgical and/or transcatheter reintervention. Death or reintervention was more common in patients with new/significant right ventricular outflow tract obstruction (69% versus 33%; P=0.042) and in patients with non-streptococcal IE (73% versus 30%; P=0.001). CONCLUSIONS: The incidence of IE after implantation of a Melody valve is significant, at least over the first 3 years after TPVI, and varies considerably between the studies. Although surgical/percutaneous reintervention is a common consequence, some patients can be managed medically, especially those with streptococcal infection and no right ventricular outflow tract obstruction.
Assuntos
Bioprótese/efeitos adversos , Endocardite/epidemiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Valva Pulmonar/cirurgia , Adolescente , Adulto , Criança , Pré-Escolar , Endocardite/diagnóstico , Endocardite/mortalidade , Endocardite/terapia , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/terapia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto JovemRESUMO
Vascular complications (VCs) after transfemoral transcatheter aortic valve implantation (TAVI) have always been reported to occur frequently. Studies addressing VCs have been conducted with older-generation prostheses. We aimed to evaluate the incidence, predictors, and impact of VCs after transfemoral TAVI with the balloon-expandable SAPIEN 3. We report a single-center retrospective analysis of 400 consecutive patients of a prospectively acquired cohort. All patients underwent transfemoral TAVI with SAPIEN 3 between January 2014 and December 2016. VC was defined according to the Valve Academic Research Consortium. In this cohort 83 patients had VCs (20.8%), 5.8% major and 15.0% minor. Sheath-to-iliofemoral artery ratio was the only predictor of major VCs (odds ratio 7.51, 95% confidence interval 1.61 to 34.95, p = 0.010). The area under the receiver-operator characteristic curve for sheath-to-iliofemoral artery ratio was 0.63 (poor accuracy). Thirty-day mortality rates were 17.4%, 1.7%, and 0.6% for major, minor, and no VCs, respectively (log-rank p ≤0.001). After adjustment, only major VCs were associated with 30-day mortality (adjusted hazard ratio 48.31, 95% confidence interval 7.80 to 299.24). Mortality from 30 days until 1 year did not differ between patients with and without VCs (log-rank p = 0.61). In conclusion we report that VCs remain an issue of transfemoral TAVI with the SAPIEN 3, and their prediction continues to be difficult, albeit the low-incidence, major VCs were associated with higher 30-day mortality. However, after these first 30 days, they were not of influence on survival anymore.