RESUMO
INTRODUCTION: Response to medical incidents in mountainous areas is delayed due to the remote and challenging terrain. Drones could assist in a quicker search for patients and can facilitate earlier treatment through delivery of medical equipment. We aim to assess the effects of using drones in search and rescue (SAR) operations in challenging terrain. We hypothesize that drones can reduce the search time and treatment-free interval of patients by delivering an emergency kit and telemedical support. METHODS: In this randomized controlled trial with a cross-over design two methods of searching for and initiating treatment of a patient were compared. The primary outcome was a comparison of the times for locating a patient through visual contact and starting treatment on-site between the drone-assisted intervention arm and the conventional ground-rescue control arm. A linear mixed model (LMM) was used to evaluate the effect of using a drone on search and start of treatment times. RESULTS: Twenty-four SAR missions, performed by six SAR teams each with four team members, were analyzed. The mean time to locate the patient was 14.6 min (95% CI 11.3-17.9) in the drone-assisted intervention arm and 20.6 min (95% CI 17.3-23.9) in the control arm. The mean time to start treatment was 15.7 min (95% CI 12.4-19.0) in the drone-assisted arm and 22.4 min (95% CI 19.1-25.7) in the control arm (p < 0.01 for both comparisons). CONCLUSION: The successful use of drones in SAR operations leads to a reduction in search time and treatment-free interval of patients in challenging terrain, which could improve outcomes in patients suffering from traumatic injuries, the most commonly occurring incident requiring mountain rescue operations.
Assuntos
Serviços Médicos de Emergência , Telemedicina , Humanos , Dispositivos Aéreos não Tripulados , Aeronaves , Trabalho de Resgate/métodos , Serviços Médicos de Emergência/métodosRESUMO
INTRODUCTION: Space travel is expected to grow in the near future, which could lead to a higher burden of sudden cardiac arrest (SCA) in astronauts. Current methods to perform cardiopulmonary resuscitation in microgravity perform below earth-based standards in terms of depth achieved and the ability to sustain chest compressions (CC). We hypothesised that an automated chest compression device (ACCD) delivers high-quality CC during simulated micro- and hypergravity conditions. METHODS: Data on CC depth, rate, release and position utilising an ACCD were collected continuously during a parabolic flight with alternating conditions of normogravity (1 G), hypergravity (1.8 G) and microgravity (0 G), performed on a training manikin fixed in place. Kruskal-Wallis and Mann-Withney U test were used for comparison purpose. RESULTS: Mechanical CC was performed continuously during the flight; no missed compressions or pauses were recorded. Mean depth of CC showed minimal but statistically significant variations in compression depth during the different phases of the parabolic flight (microgravity 49.9 ± 0.7, normogravity 49.9 ± 0.5 and hypergravity 50.1 ± 0.6 mm, p < 0.001). CONCLUSION: The use of an ACCD allows continuous delivery of high-quality CC in micro- and hypergravity as experienced in parabolic flight. The decision to bring extra load for a high impact and low likelihood event should be based on specifics of its crew's mission and health status, and the establishment of standard operating procedures.
Assuntos
Reanimação Cardiopulmonar , Hipergravidade , Voo Espacial , Ausência de Peso , Reanimação Cardiopulmonar/métodos , Humanos , ManequinsRESUMO
Accurate assessment of vital parameters is essential for diagnosis and triage of critically ill patients, but not always feasible in out-of-hospital settings due to the lack of suitable devices. We performed an extensive validation of a novel prototype in-ear device, which was proposed for the non-invasive, combined measurement of core body temperature (Tc), oxygen saturation (SpO2), and heart rate (HR) in harsh environments. A pilot study with randomized controlled design was conducted in the terraXcube environmental chamber. Participants were subsequently exposed to three 15 min test sessions at the controlled ambient temperatures of 20 °C, 5 °C, and - 10 °C, in randomized order. Vital parameters measured by the prototype were compared with Tc measurements from commercial esophageal (reference) and tympanic (comparator) probes and SpO2 and HR measurements from a finger pulse-oximeter (reference). Performance was assessed in terms of bias and Lin's correlation coefficient (CCC) with respect to the reference measurements and analyzed with linear mixed models. Twenty-three participants (12 men, mean (SD) age, 35 (9) years) completed the experimental protocol. The mean Tc bias of the prototype ranged between - 0.39 and - 0.80 °C at ambient temperatures of 20 °C and 5 °C, and it reached - 1.38 °C only after 15 min of exposure to - 10 °C. CCC values ranged between 0.07 and 0.25. SpO2 and HR monitoring was feasible, although malfunctioning was observed in one third of the tests. SpO2 and HR bias did not show any significant dependence on environmental conditions, with values ranging from - 1.71 to - 0.52% for SpO2 and 1.12 bpm to 5.30 bpm for HR. High CCC values between 0.81 and 0.97 were observed for HR in all environmental conditions. This novel prototype device for measuring vital parameters in cold environments demonstrated reliability of Tc measurements and feasibility of SpO2 and HR monitoring. Through non-invasive and accurate monitoring of vital parameters from the ear canal our prototype may offer support in triage and treatment of critically ill patients in harsh out-of-hospital conditions.
Assuntos
Temperatura Corporal , Frequência Cardíaca , Humanos , Masculino , Feminino , Adulto , Frequência Cardíaca/fisiologia , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Projetos Piloto , Oximetria/instrumentação , Oximetria/métodos , Saturação de Oxigênio/fisiologia , Pessoa de Meia-Idade , TemperaturaRESUMO
Cardiopulmonary resuscitation (CPR) is considered an aerosol-generating procedure. Consequently, COVID-19 resuscitation guidelines recommend the use of personal protective equipment (PPE) during resuscitation. In this simulation of randomised crossover trials, we investigated the influence of PPE on the quality of chest compressions (CCs). Thirty-four emergency medical service BLS-providers performed two 20 min CPR sequences (five 2 min cycles alternated by 2 min of rest) on manikins, once with and once without PPE, in a randomised order. The PPE was composed of a filtering facepiece 3 FFP3 mask, safety glasses, gloves and a long-sleeved gown. The primary outcome was defined as the difference between compression depth with and without PPE; secondary outcomes were defined as differences in CC rate, release and the number of effective CCs. The participants graded fatigue and performance, while generalised estimating equations (GEE) were used to analyse data. There was no significant difference in CC quality between sequences without and with PPE regarding depth (mean depth 54 ± 5 vs. 54 ± 6 mm respectively), rate (mean rate 119 ± 9 and 118 ± 6 compressions per minute), release (mean release 2 ± 2 vs. 2 ± 2 mm) and the number of effective CCs (43 ± 18 vs. 45 ± 17). The participants appraised higher fatigue when equipped with PPE in comparison to when equipped without PPE (p < 0.001), and lower performance was appraised when equipped with PPE in comparison to when equipped without PPE (p = 0.031). There is no negative effect of wearing PPE on the quality of CCs during CPR in comparison to not wearing PPE.
RESUMO
Background Helicopter emergency medical services personnel operating in mountainous terrain are frequently exposed to rapid ascents and provide cardiopulmonary resuscitation (CPR) in the field. The aim of the present trial was to investigate the quality of chest compression only (CCO)-CPR after acute exposure to altitude under repeatable and standardized conditions. Methods and Results Forty-eight helicopter emergency medical services personnel were divided into 12 groups of 4 participants; each group was assigned to perform 5 minutes of CCO-CPR on manikins at 2 of 3 altitudes in a randomized controlled single-blind crossover design (200, 3000, and 5000 m) in a hypobaric chamber. Physiological parameters were continuously monitored; participants rated their performance and effort on visual analog scales. Generalized estimating equations were performed for variables of CPR quality (depth, rate, recoil, and effective chest compressions) and effects of time, altitude, carryover, altitude sequence, sex, qualification, weight, preacclimatization, and interactions were analyzed. Our trial showed a time-dependent decrease in chest compression depth (P=0.036) after 20 minutes at altitude; chest compression depth was below the recommended minimum of 50 mm after 60 to 90 seconds (49 [95% CI, 46-52] mm) of CCO-CPR. Conclusions This trial showed a time-dependent decrease in CCO-CPR quality provided by helicopter emergency medical services personnel during acute exposure to altitude, which was not perceived by the providers. Our findings suggest a reevaluation of the CPR guidelines for providers practicing at altitudes of 3000 m and higher. Mechanical CPR devices could be of help in overcoming CCO-CPR quality decrease in helicopter emergency medical services missions. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT04138446.