Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(2): 382-388, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38078877

RESUMO

BACKGROUND: Evidence-based recommendations for antithrombotic treatment in patients who have an indication for oral anticoagulation (OAC) after transcatheter edge-to-edge mitral valve repair (TEER) are lacking. AIMS: To compare bleeding and thrombotic risk for different antithrombotic regimens post-TEER with MitraClip in an unselected population with the need for OACs. METHODS: Bleeding and thrombotic complications (stroke and myocardial infarction) up to 3 months after TEER with mitraclip were evaluated in 322 consecutive pts with an indication for OACs. These endpoints were defined by the Mitral Valve Academic Research Consortium criteria and were compared between two antithrombotic regimens: single antithrombotic therapy with OAC (single ATT) and double/triple ATT with a combination of OAC and aspirin and/or clopidogrel (combined ATT). RESULTS: Collectively, 108 (34%) patients received single ATT, 203 (63%) received double ATT and 11 (3%) received triple ATT. Bleeding events occurred in 67 patients (20.9%), with access site related events being the most frequent cause (37%). Bleeding complications were observed more frequently in the combined ATT group than in the single ATT group: 24% versus 14% [p = 0.03, adjusted RR: 0.55 (0.3-0.98)]. Within the combined group, the bleeding risk was 23% in the double ATT and 45% in the triple ATT group. Thrombotic complications occurred in only three patients (0.9%), and all belonged to the combined ATT group. CONCLUSIONS: In patients with an indication for OACs, withholding of antiplatelet therapy post-TEER with Mitraclip was associated with a 45% reduction in bleeding and without a signal of increased thrombotic risk.


Assuntos
Inibidores da Agregação Plaquetária , Trombose , Humanos , Inibidores da Agregação Plaquetária/efeitos adversos , Anticoagulantes/efeitos adversos , Fibrinolíticos/efeitos adversos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Hemorragia/induzido quimicamente , Trombose/etiologia , Trombose/prevenção & controle , Sistema de Registros
2.
Circulation ; 145(21): 1592-1604, 2022 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-35354306

RESUMO

BACKGROUND: In REDUCE LAP-HF II (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients With Heart Failure), implantation of an atrial shunt device did not provide overall clinical benefit for patients with heart failure with preserved or mildly reduced ejection fraction. However, prespecified analyses identified differences in response in subgroups defined by pulmonary artery systolic pressure during submaximal exercise, right atrial volume, and sex. Shunt implantation reduces left atrial pressures but increases pulmonary blood flow, which may be poorly tolerated in patients with pulmonary vascular disease (PVD). On the basis of these results, we hypothesized that patients with latent PVD, defined as elevated pulmonary vascular resistance during exercise, might be harmed by shunt implantation, and conversely that patients without PVD might benefit. METHODS: REDUCE LAP-HF II enrolled 626 patients with heart failure, ejection fraction ≥40%, exercise pulmonary capillary wedge pressure ≥25 mm Hg, and resting pulmonary vascular resistance <3.5 Wood units who were randomized 1:1 to atrial shunt device or sham control. The primary outcome-a hierarchical composite of cardiovascular death, nonfatal ischemic stroke, recurrent HF events, and change in health status-was analyzed using the win ratio. Latent PVD was defined as pulmonary vascular resistance ≥1.74 Wood units (highest tertile) at peak exercise, measured before randomization. RESULTS: Compared with patients without PVD (n=382), those with latent PVD (n=188) were older, had more atrial fibrillation and right heart dysfunction, and were more likely to have elevated left atrial pressure at rest. Shunt treatment was associated with worse outcomes in patients with PVD (win ratio, 0.60 [95% CI, 0.42, 0.86]; P=0.005) and signal of clinical benefit in patients without PVD (win ratio, 1.31 [95% CI, 1.02, 1.68]; P=0.038). Patients with larger right atrial volumes and men had worse outcomes with the device and both groups were more likely to have pacemakers, heart failure with mildly reduced ejection fraction, and increased left atrial volume. For patients without latent PVD or pacemaker (n=313; 50% of randomized patients), shunt treatment resulted in more robust signal of clinical benefit (win ratio, 1.51 [95% CI, 1.14, 2.00]; P=0.004). CONCLUSIONS: In patients with heart failure with preserved or mildly reduced ejection fraction, the presence of latent PVD uncovered by invasive hemodynamic exercise testing identifies patients who may worsen with atrial shunt therapy, whereas those without latent PVD may benefit.


Assuntos
Cateterismo Cardíaco , Átrios do Coração , Insuficiência Cardíaca , Doenças Vasculares , Cateterismo Cardíaco/instrumentação , Feminino , Átrios do Coração/cirurgia , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Circulação Pulmonar , Volume Sistólico , Resultado do Tratamento , Doenças Vasculares/complicações
3.
N Engl J Med ; 383(15): 1447-1457, 2020 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-32865376

RESUMO

BACKGROUND: The effect of single as compared with dual antiplatelet treatment on bleeding and thromboembolic events after transcatheter aortic-valve implantation (TAVI) in patients who do not have an indication for long-term anticoagulation has not been well studied. METHODS: In a randomized, controlled trial, we assigned a subgroup of patients who were undergoing TAVI and did not have an indication for long-term anticoagulation, in a 1:1 ratio, to receive aspirin alone or aspirin plus clopidogrel for 3 months. The two primary outcomes were all bleeding (including minor, major, and life-threatening or disabling bleeding) and non-procedure-related bleeding over a period of 12 months. Most bleeding at the TAVI puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2) at 1 year, with both outcomes tested sequentially for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: A total of 331 patients were assigned to receive aspirin alone and 334 were assigned to receive aspirin plus clopidogrel. A bleeding event occurred in 50 patients (15.1%) receiving aspirin alone and in 89 (26.6%) receiving aspirin plus clopidogrel (risk ratio, 0.57; 95% confidence interval [CI], 0.42 to 0.77; P = 0.001). Non-procedure-related bleeding occurred in 50 patients (15.1%) and 83 patients (24.9%), respectively (risk ratio, 0.61; 95% CI, 0.44 to 0.83; P = 0.005). A secondary composite 1 event occurred in 76 patients (23.0%) receiving aspirin alone and in 104 (31.1%) receiving aspirin plus clopidogrel (difference, -8.2 percentage points; 95% CI for noninferiority, -14.9 to -1.5; P<0.001; risk ratio, 0.74; 95% CI for superiority, 0.57 to 0.95; P = 0.04). A secondary composite 2 event occurred in 32 patients (9.7%) and 33 patients (9.9%), respectively (difference, -0.2 percentage points; 95% CI for noninferiority, -4.7 to 4.3; P = 0.004; risk ratio, 0.98; 95% CI for superiority, 0.62 to 1.55; P = 0.93). A total of 44 patients (13.3%) and 32 (9.6%), respectively, received oral anticoagulation during the trial. CONCLUSIONS: Among patients undergoing TAVI who did not have an indication for oral anticoagulation, the incidence of bleeding and the composite of bleeding or thromboembolic events at 1 year were significantly less frequent with aspirin than with aspirin plus clopidogrel administered for 3 months. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Assuntos
Aspirina/uso terapêutico , Clopidogrel/uso terapêutico , Hemorragia/induzido quimicamente , Inibidores da Agregação Plaquetária/uso terapêutico , Trombose/prevenção & controle , Substituição da Valva Aórtica Transcateter , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Aspirina/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Quimioterapia Combinada , Feminino , Hemorragia/epidemiologia , Humanos , Incidência , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Período Pós-Operatório , Trombose/epidemiologia
4.
N Engl J Med ; 382(18): 1696-1707, 2020 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-32223116

RESUMO

BACKGROUND: The roles of anticoagulation alone or with an antiplatelet agent after transcatheter aortic-valve implantation (TAVI) have not been well studied. METHODS: We performed a randomized trial of clopidogrel in patients undergoing TAVI who were receiving oral anticoagulation for appropriate indications. Patients were assigned before TAVI in a 1:1 ratio not to receive clopidogrel or to receive clopidogrel for 3 months. The two primary outcomes were all bleeding and non-procedure-related bleeding over a period of 12 months. Procedure-related bleeding was defined as Bleeding Academic Research Consortium type 4 severe bleeding, and therefore most bleeding at the puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction at 12 months (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2), both tested for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: Bleeding occurred in 34 of the 157 patients (21.7%) receiving oral anticoagulation alone and in 54 of the 156 (34.6%) receiving oral anticoagulation plus clopidogrel (risk ratio, 0.63; 95% confidence interval [CI], 0.43 to 0.90; P = 0.01); most bleeding events were at the TAVI access site. Non-procedure-related bleeding occurred in 34 patients (21.7%) and in 53 (34.0%), respectively (risk ratio, 0.64; 95% CI, 0.44 to 0.92; P = 0.02). Most bleeding occurred in the first month and was minor. A secondary composite 1 event occurred in 49 patients (31.2%) receiving oral anticoagulation alone and in 71 (45.5%) receiving oral anticoagulation plus clopidogrel (difference, -14.3 percentage points; 95% CI for noninferiority, -25.0 to -3.6; risk ratio, 0.69; 95% CI for superiority, 0.51 to 0.92). A secondary composite 2 event occurred in 21 patients (13.4%) and in 27 (17.3%), respectively (difference, -3.9 percentage points; 95% CI for noninferiority, -11.9 to 4.0; risk ratio, 0.77; 95% CI for superiority, 0.46 to 1.31). CONCLUSIONS: In patients undergoing TAVI who were receiving oral anticoagulation, the incidence of serious bleeding over a period of 1 month or 1 year was lower with oral anticoagulation alone than with oral anticoagulation plus clopidogrel. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Assuntos
Anticoagulantes/uso terapêutico , Clopidogrel/uso terapêutico , Hemorragia/induzido quimicamente , Inibidores da Agregação Plaquetária/uso terapêutico , Substituição da Valva Aórtica Transcateter , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Quimioterapia Combinada , Hemorragia/epidemiologia , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos
5.
Catheter Cardiovasc Interv ; 93(3): E134-E139, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30411845

RESUMO

AIMS: To identify risk factors for composite outcome of mortality, stroke or myocardial infarction in patients with severe carotid stenosis undergoing staged carotid artery stenting (CAS) with subsequent cardiac surgery. METHODS AND RESULTS: In this prospective observational study, we enrolled 643 consecutive patients with both symptomatic (i.e., with history of stroke) and asymptomatic severe carotid artery disease, who required cardiac surgery. Generally, cardiac surgery was planned 30 days after the CAS procedure. The composite outcome consisted of death, stroke and myocardial infarction. The composite outcome rate was 26.3% at 5 years and 47% at 8 years after CAS. Age ≥ 80 years (hazard ratio [HR] = 1.89; 95%CI, 1.18-3.03; P = 0.008), history of stroke (HR = 1.66, 1.16-2.37; P = 0.006), chronic obstructive pulmonary disease (HR = 1.86; 1.07-3.24; P = 0.03) and kidney disease (HR = 1.83, 1.11-3.04; P = 0.02) were independent risk factors for the composite outcome during long-term follow-up. CONCLUSIONS: In this study with staged CAS followed by cardiac surgery, we confirm previously reported event-free survival rates and identify several risk factors for the composite outcome. Future studies are needed to confirm the importance of the identified risk factors and to assess their predictive ability.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Estenose das Carótidas/terapia , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervalo Livre de Progressão , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo
6.
Catheter Cardiovasc Interv ; 93(6): 1097-1105, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30461187

RESUMO

OBJECTIVE: The aim of this study was to describe the early use of dedicated patient specific computer modeling in patients with bicuspid aortic valve (BAV) undergoing transcatheter aortic valve implantation (TAVI), in predicting procedure feasibility and patient related outcome. BACKGROUND: Dedicated patient specific computer modeling, used for optimizing TAVI procedures, is currently validated for the prediction of contact pressure, valve morphology and paravalvular leakage (PVL). The simulation of TAVI procedures is increasingly used in patients with tricuspid aortic valve stenosis. Currently, BAV disease is considered as a relative contra-indication for TAVI due to its specific anatomical characteristics. METHODS: This single center study consisted of seven patients with BAV undergoing TAVI. A patient specific computer simulation was performed based on multislice computer tomography images. The model advised the best fitting prosthetic valve size or sizes and simulated this valve on different implantation depths with the corresponding presence and severity of PVL and prosthetic valve morphology. The simulation results were compared with the procedural outcomes using transesophageal echocardiography (TEE) and fluoroscopy. RESULTS: The patient specific computer modeling predicted accurately the outcome (PVL and valve morphology) of TAVI in all cases. In one case, the TAVI procedure was unsuccessful and retrospectively not suitable for TAVI, which was correctly predicted by the model. CONCLUSION: The patient specific computer modeling adequately predicts feasibility and outcome of TAVI in patients with BAV disease and may extend the applicability of TAVI. Moreover, it improves decision-making and therefore individual procedural outcomes in this difficult patient population.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/complicações , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Cirurgia Assistida por Computador , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Tomada de Decisão Clínica , Técnicas de Apoio para a Decisão , Estudos de Viabilidade , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Seleção de Pacientes , Desenho de Prótese , Estudos Retrospectivos , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
7.
Curr Cardiol Rep ; 21(5): 37, 2019 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-30924027

RESUMO

PURPOSE OF REVIEW: This review aims to provide an updated overview and a clinical perspective on novel transcatheter tricuspid valve interventions (TTVI), highlighting potential challenges and future directions. RECENT FINDINGS: Severe tricuspid regurgitation (TR) is a predictor of mortality. However, a sizeable number of patients remain untreated until the end-stage when cardiac surgery presents a prohibitive risk. The emergent need in finding a treatment for patients with TR, deemed for surgery options, has encouraged the development of TTVI. These procedures mimic classical surgery techniques and are mainly divided in four categories: annuloplasty and coaptation devices, edge-to-edge techniques and transcatheter tricuspid valve replacement. Early studies showed promising results, but long-term follow-up data are not available. For patients with severe TR and high surgical risk, several percutaneous options are available. However, these therapies are in a growing phase and bigger studies and long term follow-up are needed to prove their efficacy.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Humanos , Resultado do Tratamento
8.
Lancet ; 390(10113): 2655-2661, 2017 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-28870716

RESUMO

BACKGROUND: Carotid baroreflex activation lowers blood pressure and might have potential application for the treatment of resistant hypertension. We did a proof-of-principle trial with a novel endovascular baroreceptor amplification device, MobiusHD (Vascular Dynamics, Mountain View, CA, USA), in patients with resistant hypertension. METHODS: CALM-FIM_EUR was a prospective, first-in-human, open-label study done at six European centres. Eligible patients were adults with resistant hypertension (office systolic blood pressure ≥160 mm Hg despite taking at least three antihypertensive agents, including a diuretic). MobiusHD devices were implanted unilaterally in the internal carotid artery. The primary endpoint was the incidence of serious adverse events at 6 months. Secondary endpoints included changes in office and 24 h ambulatory blood pressure. This trial is registered with ClinicalTrials.gov, number NCT01911897. FINDINGS: Between December, 2013, and February, 2016, 30 patients were enrolled and underwent successful implantation. Mean age was 52 years (SD 12), 15 patients (50%) were men, and mean antihypertensive use was 4·4 drugs (1·4). Mean office blood pressure was 184/109 mm Hg (18/14) at baseline and was reduced by 24/12 mm Hg (13-34/6-18) at 6 months (p=0·0003 for systolic and p=0·0001 diastolic blood pressure). Mean baseline 24 h ambulatory blood pressure was 166/100 mm Hg (17/14) at baseline and was reduced by 21/12 mm Hg (14-29/7-16) at 6 months (p<0·0001 for systolic and diastolic blood pressure). Five serious adverse events had occurred in four patients (13%) at 6 months: hypotension (n=2), worsening hypertension (n=1), intermittent claudication (n=1) and wound infection (n=1). INTERPRETATION: In patients with resistant hypertension, endovascular baroreceptor amplification with the MobiusHD device substantially lowered blood pressure with an acceptable safety profile. Randomised, double-blind, sham-controlled trials are warranted to investigate the use of this treatment further. FUNDING: Vascular Dynamics.


Assuntos
Barorreflexo/fisiologia , Implante de Prótese Vascular , Prótese Vascular , Seio Carotídeo/fisiologia , Hipertensão/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
9.
Catheter Cardiovasc Interv ; 92(5): E299-E307, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29411523

RESUMO

BACKGROUND: Coronary chronic total occlusions (CTO) usually coexist with diffusely diseased coronary segments proximal and/or distal to the CTO segment. During percutaneous treatment of CTO, multiple overlapping stents are often needed to treat these long lesions. OBJECTIVES: Aim of this study is to report the first use of long, tapered coronary sirolimus-eluting stents (SES) in this setting. METHODS AND RESULTS: This is a retrospective analysis of 100 consecutive patients undergoing CTO recanalization following the hybrid algorithm. Procedural success rate was 89% (11 failures). Among the successful cases, "conventional" drug-eluting stents(DES) were used in 40(44.9%) patients, while in 49(55%) patients long-tapered SES were attempted with a success rate of 98% (1 cross-over to regular stents). Total stent length in the long-tapered DES group was higher compared to the "conventional" stenting group (76 ± 28 mm vs 46 ± 22 mm, P < .001), with a similar total number of stent (1.6 ± 0.8 vs 1.9 ± 0.8). At quantitative coronary analysis, proximal and distal segment involvement was more extended in patients undergoing long-tapered stenting, with longer overall lesion length. No differences in periprocedural complications and clinical outcomes at a mean follow-up of 303 ± 179 days were observed. CONCLUSIONS: The use of long tapered coronary DES is technically feasible and safe for the percutaneous treatment of CTOs, especially for patients presenting with long lesions.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Oclusão Coronária/terapia , Stents Farmacológicos , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
10.
Lancet ; 387(10025): 1298-304, 2016 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-27025436

RESUMO

BACKGROUND: Heart failure with preserved ejection fraction (HFPEF) is a common, globally recognised, form of heart failure for which no treatment has yet been shown to improve symptoms or prognosis. The pathophysiology of HFPEF is complex but characterised by increased left atrial pressure, especially during exertion, which might be a key therapeutic target. The rationale for the present study was that a mechanical approach to reducing left atrial pressure might be effective in HFPEF. METHODS: The REDUCe Elevated Left Atrial Pressure in Patients with Heart Failure (REDUCE LAP-HF) study was an open-label, single-arm, phase 1 study designed to assess the performance and safety of a transcatheter interatrial shunt device (IASD, Corvia Medical, Tewkesbury, MA, USA) in patients older than 40 years of age with symptoms of HFPEF despite pharmacological therapy, left ventricular ejection fraction higher than 40%, and a raised pulmonary capillary wedge pressure at rest (>15 mm Hg) or during exercise (>25 mm Hg). The study was done at 21 centres (all departments of cardiology in the UK, Netherlands, Belgium, France, Germany, Austria, Denmark, Australia, and New Zealand). The co-primary endpoints were the safety and performance of the IASD at 6 months, together with measures of clinical efficacy, including functional capacity and clinical status, analysed per protocol. This study is registered with ClinicalTrials.gov, number NCT01913613. FINDINGS: Between Feb 8, 2014, and June 10, 2015, 68 eligible patients were entered into the study. IASD placement was successful in 64 patients and seemed to be safe and well tolerated; no patient had a peri-procedural or major adverse cardiac or cerebrovascular event or need for cardiac surgical intervention for device-related complications during 6 months of follow-up. At 6 months, 31 (52%) of 60 patients had a reduction in pulmonary capillary wedge pressure at rest, 34 (58%) of 59 had a lower pulmonary capillary wedge pressure during exertion, and 23 (39%) of 59 fulfilled both these criteria. Mean exercise pulmonary capillary wedge pressure was lower at 6 months than at baseline, both at 20 watts workload (mean 32 mm Hg [SD 8] at baseline vs 29 mm Hg [9] at 6 months, p=0·0124) and at peak exercise (34 mm Hg [8] vs 32 [8], p=0·0255), despite increased mean exercise duration (baseline vs 6 months: 7·3 min [SD 3·1] vs 8·2 min [3·4], p=0·03). Sustained device patency at 6 months was confirmed by left-to-right shunting (pulmonary/systemic flow ratio: 1·06 [SD 0·32] at baseline vs 1·27 [0·20] at 6 months, p=0·0004). INTERPRETATION: Implantation of an interatrial shunt device is feasible, seems to be safe, reduces left atrial pressure during exercise, and could be a new strategy for the management of HFPEF. The effectiveness of IASD compared with existing treatment for patients with HFPEF requires validation in a randomised controlled trial. FUNDING: Corvia Medical Inc.


Assuntos
Insuficiência Cardíaca/cirurgia , Idoso , Cateterismo Cardíaco , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Estudos Prospectivos , Implantação de Prótese , Volume Sistólico
11.
J Heart Valve Dis ; 26(6): 651-658, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-30207115

RESUMO

BACKGROUND: The MitraClip® system is a percutaneous treatment for mitral regurgitation (MR) that has shown promising results in patients who are inoperable or at high risk for mitral surgery. Data on the efficacy of the system over optimal medical therapy, above all in patients with functional MR, are scarce. The study aim was to assess the effect of MitraClip on the survival of patients with moderate/severe or severe MR compared to medical therapy, using meta-analytical techniques. METHODS: Independently, reviewers searched electronically for relevant articles based on predefined criteria and end-points. Only articles with a comparison between MitraClip and conservative therapy were included. Standard meta-analysis techniques were used. The primary outcomes were 30-day and one-year mortalities. RESULTS: Five observational reports were included that enrolled a total of 1,271 patients: 720 patients underwent percutaneous mitral valve repair (PMVR) with the MitraClip device, and 551 were managed conservatively. A total of 49 all-cause mortality events was reported at 30 days: 3.05% (22/720) in the PMVR arm, and 4.90% (27/510) in the conservative group, with no significant differences in all-cause mortality (OR 0.64; 95% CI 0.36-1.14). A total of 269 all-cause mortality events at one year was reported: 15.14% (109/720) in the PMVR arm, and 29.04% (160/551) in the conservative group. A significant difference favoring PMVR with the MitraClip system over medical therapy alone was observed (OR 0.44; 95% CI 0.30-0.64, p <0.0001). Neither significance between study heterogeneity (p = 0.18) nor publication bias was detected (p = 0.3). CONCLUSIONS: PMVR with the MitraClip system may be associated with an improvement in one-year survival compared to stand-alone medical management.


Assuntos
Procedimentos Endovasculares/instrumentação , Insuficiência da Valva Mitral/terapia , Valva Mitral/cirurgia , Tratamento Conservador , Humanos , Insuficiência da Valva Mitral/mortalidade
12.
Catheter Cardiovasc Interv ; 87(3): 467-75, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26268819

RESUMO

OBJECTIVES: To evaluate long-term survival in high surgical risk patients undergoing percutaneous mitral valve repair (MVR) using the MitraClip(®) system and to identify preprocedural predictors of long-term mortality. BACKGROUND: Data for long-term survival and preprocedural predictors of mortality after percutaneous MVR in high surgical risk patients are sporadic. METHODS: From January 2009 to April 2013, 136 consecutive high surgical risk patients, with symptomatic moderate-to-severe or severe mitral regurgitation (MR), underwent percutaneous MVR using the MitraClip system. Cardiac and overall survival was determined at one and 2 years postprocedure. Univariate and multivariate analysis was performed to identify preprocedural predictors of long-term mortality. RESULTS: One year postprocedure, cardiac and overall survival was 86.7% and 84.6%, respectively and at 2 years cardiac and overall survival was 77.7% and 74.8%, respectively. In univariate analysis advanced age, lower body mass index, impaired renal function, elevated levels of log-N-terminal-pro-brain-natriuretic-peptide (log-NTproBNP), poor performance in functional tests (New York Heart Association (NYHA) class) and high logistic Euroscore (LES) and Society of Thoracic Surgeons (STS) score were identified as preprocedural predictors of long-term cardiac mortality. In multivariate analysis preoperative NYHA class III and IV, elevated levels of log-NTproBNP and advanced age predicted long-term cardiac mortality. CONCLUSIONS: Percutaneous MVR using the MitraClip system has favorable long-term survival rates in high surgical risk patients. Preprocedural NYHA functional class III and IV, elevated log-NTproBNP levels and advanced age predict higher long-term cardiac mortality and should be considered during patient selection.


Assuntos
Cateterismo Cardíaco/mortalidade , Implante de Prótese de Valva Cardíaca/mortalidade , Insuficiência da Valva Mitral/terapia , Valva Mitral , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Análise Multivariada , Modelos de Riscos Proporcionais , Desenho de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 86 Suppl 1: S28-33, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25754236

RESUMO

AIMS: We sought to evaluate the procedural and clinical performances of the MGuard Prime Embolic Protection Stent (EPS) in a "real-world" population with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PPCI). METHODS AND RESULTS: Consecutive STEMI patients meeting the inclusion criteria and undergoing PPCI were enrolled. The primary endpoint was major adverse cardiac events (MACE) at 30 days, defined as the composite of cardiac death, myocardial infarction (Q wave and non-Q wave) or target lesion revascularization (PCI or coronary artery bypass graft). Secondary endpoints included device success, lesion success, and postprocedural reperfusion outcomes: thrombolysis in myocardial infarction (TIMI) flow and ST-segment elevation resolution (STR). A total of 97 patients (62 years, 77% men) were included. Symptom to cathlab time was 238 min. Device and lesion success were 100%. Final TIMI-3 flow was achieved in 91.8%, and STR > 50% in 87% of the patients. MACE at 30 days was 2.2%, which consisted of one case each of target vessel (TV)-myocardial infarction (MI), and non-TV-MI. CONCLUSIONS: The use of the MGuard Prime EPS stent is feasible and safe and could be also effective in achieving myocardial reperfusion in STEMI patients undergoing PPCI.


Assuntos
Eletrocardiografia , Dispositivos de Proteção Embólica , Embolia/prevenção & controle , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea/métodos , Vigilância de Produtos Comercializados/métodos , Stents , Angiografia Coronária , Seguimentos , Humanos , Infarto do Miocárdio/diagnóstico por imagem , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
14.
Acta Cardiol ; 79(1): 46-57, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38450496

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) with the SAPIEN 3 device has recently shown significant clinical benefits, compared to surgical aortic valve replacement (SAVR), in patients at low risk for surgical mortality (PARTNER 3 trial, NCT02675114). Currently in Belgium, TAVI use is restricted to high-risk or inoperable patients with severe symptomatic aortic stenosis (sSAS). This cost-utility analysis aimed to assess whether TAVI with SAPIEN 3 could lead to potential cost-savings compared with SAVR, in the low-risk sSAS population in Belgium. METHODS: A previously published, two-stage, Markov-based cost-utility model was used. Clinical outcomes were captured using data from PARTNER 3 and the model was adapted for the Belgian context using cost data from the perspective of the Belgian National Healthcare System, indexed to 2022. A lifetime horizon was chosen. The model outputs included changes in direct healthcare costs, survival and health-related quality of life using TAVI versus SAVR. RESULTS: TAVI with SAPIEN 3 provides meaningful clinical and cost benefits over SAVR, in terms of an increase in quality-adjusted life years (QALYs) of 0.94 and cost-saving of €3 013 per patient. While initial procedure costs were higher for TAVI compared with SAVR, costs related to rehabilitation, disabling stroke, treated atrial fibrillation, and rehospitalization were lower. The cost-effectiveness of TAVI over SAVR remained robust in sensitivity analyses. CONCLUSION: TAVI with SAPIEN 3 may offer a meaningful alternative intervention to SAVR in Belgian low-risk patients with sSAS, showing both clinical benefits and cost savings associated with post-procedure patient management.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bélgica/epidemiologia , Constrição Patológica , Análise de Custo-Efetividade , Qualidade de Vida , Ensaios Clínicos como Assunto
15.
Clin Res Cardiol ; 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38619575

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) serves a growing range of patients with severe aortic stenosis (AS). TAVI has evolved to a streamlined procedure minimizing length of hospital stay. AIMS: To evaluate the safety and efficacy of an early discharge (ED) strategy after TAVI. METHODS: We performed an international, multi-center, prospective observational single-arm study in AS patients undergoing TAVI with the ACURATE valve platform. Eligibility for ED was assessed prior to TAVI and based on prespecified selection criteria. Discharge ≤ 48 h was defined as ED. Primary Valve Academic Research Consortium (VARC)-3-defined 30-day safety and efficacy composite endpoints were landmarked at 48 h and compared between ED and non-ED groups. RESULTS: A total of 252 patients were included. The median age was 82 [25th-75th percentile, 78-85] years and the median Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score was 2.2% [25th-75th percentile, 1.6-3.3]. ED and non-ED were achieved in 173 (69%) and 79 (31%) patients respectively. Monitoring for conduction disturbances was the principal reason for non-ED (33%). Overall, at 30 days, all-cause mortality was 1%, new permanent pacemaker rate was 4%, and valve- or procedure-related rehospitalization was 4%. There was no difference in the primary safety and efficacy endpoint between the ED and non-ED cohorts (OR 0.84 [25th-75th percentile, 0.31-2.26], p = 0.73, and OR 0.97 [25th-75th percentile, 0.46-2.06], p = 0.94). The need for rehospitalization was similarly low for ED and non-ED groups. CONCLUSION: Early discharge after TAVI with the ACURATE valve is safe and feasible in selected patients. Rhythm monitoring and extended clinical observation protracted hospital stay.

16.
JAMA Cardiol ; 8(7): 703-708, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37203243

RESUMO

Importance: Titanium-nitride-oxide (TiNO)-coated stents show faster strut coverage compared with drug-eluting stents without excessive intimal-hyperplasia observed in bare metal stents. It is important to study long-term clinical outcomes after treatment of patients with an acute coronary syndrome (ACS) by TiNO-coated stents, which are neither drug-eluting stents nor bare metal stents. Objective: To compare the rate of main composite outcome of cardiac death, myocardial infarction (MI), or ischemia-driven target lesion revascularization at 5 years in patients with ACS randomized to receive either a TiNO-coated stent or a third-generation everolimus-eluting stent (EES). Design, Setting, and Participants: This multicenter, randomized, controlled, open-label trial was conducted in 12 clinical sites in 5 European countries and enrolled patients from January 2014 to August 2016. Patients presenting with ACS (ST-segment elevation MI, non-ST-segment elevation MI, and unstable angina) with at least 1 de novo lesion were randomized to receive either a TiNO-coated stent or an EES. The present report analyzes the long-term follow-up for the main composite outcome and its individual components. Analysis took place between November 2022 to March 2023. Main outcome: The primary end point was a composite of cardiac death, MI, or target lesion revascularization at 12-month follow-up. Results: A total of 1491 patients with ACS were randomly assigned to receive either TiNO-coated stents (989 [66.3%]) or EES (502 [33.7%]). The mean (SD) age was 62.7 (10.8) years, and 363 (24.3%) were female. At 5 years, the main composite outcome events occurred in 111 patients (11.2%) in the TiNO group vs 60 patients (12%) in the EES group (hazard ratio [HR], 0.94; 95% CI, 0.69-1.28; P = .69). The rate of cardiac death was 0.9% (9 of 989) vs 3.0% (15 of 502) (HR, 0.30; 95% CI, 0.13-0.69; P = .005), the rate of MI was 4.6% (45 of 989) vs 7.0% (35 of 502) (HR, 0.64; 95% CI, 0.41-0.99; P = .049), the rate of stent thrombosis was 1.2% (12 of 989) vs 2.8% (14 of 502) (HR, 0.43; 95% CI, 0.20-0.93; P = .034), and the rate of target lesion revascularization was 7.4% (73 of 989) vs 6.4% (32 of 502) (HR, 1.16; 95% CI, 0.77-1.76; P = .47) in the TiNO-coated stent arm and in the EES arm, respectively. Conclusion and relevance: In this study, patients with ACS had a main composite outcome that was not different 5 years after TiNO-coated stent or EES. Trial Registration: ClinicalTrials.gov Identifier: NCT02049229.


Assuntos
Síndrome Coronariana Aguda , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Everolimo/farmacologia , Everolimo/uso terapêutico , Síndrome Coronariana Aguda/cirurgia , Síndrome Coronariana Aguda/tratamento farmacológico , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Stents , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Morte
17.
EuroIntervention ; 18(12): 977-986, 2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36093795

RESUMO

BACKGROUND: The ACURATE neo2 (NEO2) and Evolut PRO/PRO+ (PRO) bioprostheses are new-generation self-expanding valves developed for transcatheter aortic valve replacement (TAVR). AIMS: We sought to compare the performance of the ACURATE neo2 and Evolut PRO/PRO+ devices. METHODS: The NEOPRO-2 registry retrospectively included patients who underwent TAVR for severe aortic stenosis with either the NEO2 or PRO devices between August 2017 and December 2021 at 20 centres. In-hospital and 30-day Valve Academic Research Consortium (VARC)-3 defined outcomes were evaluated. Propensity score (PS) matching and binary logistic regression were performed to adjust the treatment effect for PS quintiles. A subgroup analysis assessed the impact of aortic valve calcification. RESULTS: A total of 2,175 patients (NEO2: n=763; PRO: n=1,412) were included. The mean age was 82±6.2 years and the mean Society of Thoracic Surgeons score was 4.2%. Periprocedural complications were low, and both groups achieved high rates of technical success (93.1% vs 94.1%; p=0.361) and predischarge intended valve performance (96.0% vs 94.1%; p=0.056), both in the unmatched and matched analysis (452 pairs). Device success at 30 days was comparable (84.3% vs 83.6%; p=0.688), regardless of aortic valve calcification severity (p>0.05 for interaction). A suggestion for higher VARC-3 early safety in the NEO2 group was mainly driven by reduced rates of new permanent pacemaker implantation (7.7% vs 15.6%; p<0.001). CONCLUSIONS: This retrospective analysis reports a similar short-term performance of the ACURATE neo2 platform compared with the new-generation Evolut PRO/PRO+ devices. Randomised studies are needed to confirm our exploratory findings.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
18.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37480891

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Incidência , Bloqueio de Ramo , Prognóstico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
EuroIntervention ; 19(9): 766-771, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37605804

RESUMO

About one-third of patients undergoing transcatheter aortic valve implantation (TAVI) use oral anticoagulants (OAC), mainly due to atrial fibrillation. General guidelines advise interrupting OAC in patients with a high risk of bleeding undergoing interventions. However, preliminary observational data suggest that the continuation of OAC during TAVI is safe and may reduce the risk of periprocedural thromboembolic events. The Periprocedural Continuation Versus Interruption of Oral Anticoagulant Drugs During Transcatheter Aortic Valve Implantation (POPular PAUSE TAVI) is a multicentre, randomised clinical trial with open-label treatment and blinded endpoint assessment. Patients are randomised 1:1 to periprocedural continuation versus interruption of OAC and are stratified for vitamin K antagonist or direct oral anticoagulant use. The primary endpoint is a composite of cardiovascular mortality, all stroke, myocardial infarction, major vascular complications and type 2-4 bleeding within 30 days after TAVI, according to the Valve Academic Research Consortium-3 criteria. Secondary endpoints include separate individual and composite outcomes, quality of life and cost-effectiveness. Since continuation of OAC is associated with the ancillary benefit that it simplifies periprocedural management, the primary outcome is first analysed for non-inferiority; if non-inferiority is proven, superiority will be tested. Recruitment started in November 2020, and the trial will continue until a total of 858 patients have been included and followed for 90 days. In summary, POPular PAUSE TAVI is the first randomised clinical trial to assess the safety and efficacy of periprocedural continuation versus interruption of OAC in patients undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Qualidade de Vida , Anticoagulantes/uso terapêutico , Hemorragia , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
20.
Circ Cardiovasc Interv ; 16(1): e012538, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36649387

RESUMO

BACKGROUND: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. METHODS: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. RESULTS: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001). CONCLUSIONS: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Tempo , Resultado do Tratamento , Sistema de Registros , Desenho de Prótese , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA