Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Knee Surg Sports Traumatol Arthrosc ; 31(2): 716-723, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36441219

RESUMO

PURPOSE: The size of osteochondral lesions of the talus (OLTs) is highly relevant for their treatment. In addition to intraoperative measurement of defect size, preoperative planning by means of magnetic resonance imaging (MRI) or computed tomography (CT) is crucial. METHODS: Four defects of different sizes and depths were created on the talar joint surface in 14 cadaver feet. All defects were evaluated, both arthroscopically and via arthrotomy with a probe. Arthro-MRI (MR-A) and high-resolution flat-panel CT arthro scans (FPCT-A) were acquired. Length, width, and depth were measured for every defect and the defect volume was calculated. To determine the exact defect size, each talar defect was filled with plastic pellets to form a cast and the casts were scanned using FPCT to create a 3D multiplanar reconstruction data set. Finally, the surgically measured values were compared with the radiological values and the exact defect size. RESULTS: Overall, the surgically measured values (both arthroscopic and open) underestimated the exact defect size (p < 0.05). Arthroscopically determined defect length and width showed the largest deviation (p < 0.05) and underestimated the size in comparison with MR-A and FPCT-A. The FPCT-A measurements demonstrated higher correlation with both the arthroscopic and open surgical measurements than did the MR-A measurements (p < 0.05). CONCLUSION: The exact defect size is underestimated on intraoperative measurement, in both arthroscopic and open approaches. Arthroscopic defect size measurement underestimates defect size in comparison with MR-A and FPCT-A. FPCT-A was shown to be a reliable imaging technique that allows free image reconstruction in every plane and could be considered as the new reference standard for preoperative evaluation of defect size in OLT.


Assuntos
Tálus , Humanos , Tálus/diagnóstico por imagem , Tálus/cirurgia , Tálus/patologia , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética
2.
Eur Radiol ; 32(5): 2875-2882, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34902060

RESUMO

OBJECTIVES: To evaluate the impact of the reconstructed field-of-view (FOV) on image quality in computed-tomography angiography (CTA) of the lower extremities. METHODS: A total of 100 CTA examinations of the lower extremities were acquired on a 2 × 192-slice multidetector CT (MDCT) scanner. Three different datasets were reconstructed covering both legs (standard FOV size) as well as each leg separately (reduced FOV size). The subjective image quality was evaluated for the different vessel segments (femoral, popliteal, crural, pedal) by three readers using a semi-quantitative Likert scale. Additionally, objective image quality was assessed using an automated image quality metric on a per-slice basis. RESULTS: The subjective assessment of the image quality showed an almost perfect interrater agreement. The image quality of the small FOV datasets was rated significantly higher as compared to the large datasets for all patients and vessel segments (p < 0.05) with a tendency towards a higher effect in smaller vessels. The difference of the mean scores between the group with the large FOV and small FOV was 0.68 for the femoral level, 0.83 for the popliteal level, 1.12 for the crural level, and 1.08 for the pedal level. The objective image quality metric also demonstrated a significant improvement of image quality in the small FOV datasets. CONCLUSIONS: Side-separated reconstruction of each leg in CTA of the lower extremities using a small reconstruction FOV significantly improves image quality as compared to a standard reconstruction with a large FOV covering both legs. KEY POINTS: • In CT angiography of the lower legs, the side-separated reconstruction of each leg using a small field-of-views improves image quality as compared to a standard reconstruction covering both legs. • The side-separated reconstruction can be readily implemented at every commercially available CT scanner. • There is no need for additional hardware or software and no additional burden to the patient.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada Multidetectores , Angiografia , Angiografia por Tomografia Computadorizada/métodos , Humanos , Extremidade Inferior/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Tomógrafos Computadorizados
3.
Internist (Berl) ; 63(5): 545-550, 2022 May.
Artigo em Alemão | MEDLINE | ID: mdl-35195756

RESUMO

Here, we report on a patient with deep vein thrombosis of the right leg, in whom diagnostic work-up revealed a previously unknown chondrosarcoma of the tibia. Physical examination revealed a firm, nondisplaceable mass on the dorsal side of the right knee that appeared as a cystic formation on ultrasound. X­ray, computed tomography, and magnetic resonance imaging were consistent with chondrosarcoma, which had likely provoked the thrombosis by local compression or paraneoplastic mechanisms. After resection of the tumor, anticoagulation was continued. In a review of all findings, a final diagnosis of highly differentiated chondrosarcoma with thrombosis of the popliteal vein was made.


Assuntos
Neoplasias Ósseas , Condrossarcoma , Trombose , Trombose Venosa , Neoplasias Ósseas/complicações , Neoplasias Ósseas/diagnóstico , Neoplasias Ósseas/cirurgia , Humanos , Ultrassonografia/métodos , Trombose Venosa/diagnóstico , Trombose Venosa/etiologia
4.
Knee Surg Sports Traumatol Arthrosc ; 29(1): 170-180, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32060592

RESUMO

PURPOSE: Treatment of anterior glenoid bone loss in patients with recurrent anterior shoulder instability is a challenge. The subscapular sling method with quadriceps tendon bone (QTB) graft is a modification of the subscapular sling with a semitendinosus (ST) graft. The aim of the study was to test the biomechanical stability of the QTB sling procedure in human shoulder cadavers with severe anterior glenoid bone loss. METHODS: Fourteen cadaveric shoulders were tested with a force-moment-guided robot in three conditions: physiologically intact, anterior glenoid bone resection, and the subscapular sling procedure with a QTB graft. Joint stability was measured in anterior, anterior inferior and inferior directions in four glenohumeral joint positions: 0° and 60° of glenohumeral abduction, with each at 0° and 60° of external rotation. Maximum external rotation was measured at 0° and 60° glenohumeral abduction. Computer tomography scans were obtained preoperatively to plan the glenoid bone resection, as well as postoperatively to calculate the proportion of the glenoid bone actually resected. RESULTS: Significantly decreased translations were observed in the shoulders with the QTB sling compared to the intact joint and the glenoid bone loss model. No significant differences in maximum external rotation were observed between the three different conditions. CONCLUSION: This biomechanical study revealed a significant stabilizing effect of the arthroscopic subscapular QTB graft sling procedure in human shoulder cadavers without compromising external rotation. Clinical trials may reveal the usefulness of this experimental method.


Assuntos
Artroscopia/métodos , Transplante Ósseo/métodos , Instabilidade Articular/cirurgia , Escápula/cirurgia , Articulação do Ombro/cirurgia , Tendões/transplante , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Instabilidade Articular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Músculo Quadríceps/cirurgia , Rotação , Luxação do Ombro/fisiopatologia , Luxação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia
5.
Unfallchirurg ; 124(9): 695-703, 2021 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-34324034

RESUMO

Radiological diagnostics play a key role in the identification and assessment of pathological fractures. Conventional projection radiography is still the mainstay of imaging investigations. With knowledge of the patient history, the morphology and location of a fracture as well as concomitant findings, such as osteolysis or periosteal reactions can add valuable information on the origin of the fracture. Magnetic resonance imaging (MRI) is the imaging modality of choice for the local diagnostic work-up as it provides insights into the medullary cavity and visualizes potential extraosseous tumor tissue in the fracture zone. Computed tomography (CT) imaging provides valuable information on the morphological features of fractures and is useful for the planning of the surgical approach. Furthermore, it is the modality of choice for whole-body staging. In most cases of pathological fractures without a history of malignancy, a biopsy and histological work-up is recommended.


Assuntos
Fraturas Ósseas , Fraturas Espontâneas , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fraturas Espontâneas/diagnóstico por imagem , Fraturas Espontâneas/cirurgia , Humanos , Imageamento por Ressonância Magnética , Radiografia , Tomografia Computadorizada por Raios X
6.
Unfallchirurg ; 124(9): 704-719, 2021 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-34427698

RESUMO

Pathological fractures of the extremities frequently lead to uncertainty with respect to the treatment strategy and timing. The origin of metastases is typically breast, bronchial, renal and prostate cancer and myelomas. Primary bone tumors play a subordinate role. The majority affect the femur, humerus and occasionally the tibia. Surgery is typically the first line treatment as healing under conservative treatment is unlikely. The most important goal is to relieve pain and the preservation or restoration of function. For correct assessment of indications, analysis of the fracture pattern and oncological aspects including dignity, entity, prognosis, metastatic status and the general condition of the patient need to be taken into consideration. Based on all these aspects the surgical approach can be chosen. Treatment options range from osteosynthetic stabilization and augmentation osteosynthesis up to endoprosthesis replacement. The treatment is carried out in an interdisciplinary procedure as additional measures need to be addressed in addition to the surgical treatment.


Assuntos
Neoplasias Ósseas , Fraturas Espontâneas , Neoplasias Ósseas/cirurgia , Extremidades , Fêmur , Fixação Interna de Fraturas , Fraturas Espontâneas/cirurgia , Humanos , Úmero , Masculino , Estudos Retrospectivos , Resultado do Tratamento
7.
Radiologe ; 60(6): 541-548, 2020 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-32333035

RESUMO

BACKGROUND: The shoulder girdle is a chain of bones and joints which connect the upper extremity to the axial skeleton. The shoulder as a biomechanical unit has a remarkable range of motion and is therefore frequently prone to injuries of the three major joints (sternoclavicular joint, acromioclavicular joint, glenohumeral joint) and the bony elements (clavicle, scapula, humerus). Projection radiography is still the first imaging modality for injuries of the shoulder and usually sufficient for initial diagnosis and injury classification. Computed tomography (including 3D reconstructions) and magnetic resonance imaging provide additional useful information for the detection of accompanying soft-tissue injury, for surgical planning and in cases of complex anatomy (e.g., scapular fractures). PURPOSE: We aim to describe the fundamentals of injuries of the shoulder girdle and the proximal humerus with special emphasis on radiological diagnostics. MATERIALS AND METHODS: A selective PubMed literature search was performed using the following terms: "sternoclavicular joint dislocation", "clavicle fracture", "acromioclavicular joint injury", "scapular fracture", "shoulder dislocation", "proximal humerus fracture", and "shoulder girdle injuries". RESULTS: The article describes the basics of the anatomy, the trauma mechanism and the epidemiology of the most common injuries of the shoulder girdle and the proximal humerus. Special emphasis is given to radiological diagnostics, including basic projection radiography and advanced cross-sectional imaging.


Assuntos
Articulação Acromioclavicular , Fraturas Ósseas , Articulação do Ombro , Clavícula , Fraturas Ósseas/diagnóstico por imagem , Humanos , Escápula , Ombro
8.
Neuroradiology ; 61(8): 935-942, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31161261

RESUMO

PURPOSE: To evaluate technical success and long-term outcome of CT-guided radiofrequency ablation (RFA) of spinal osteoid osteomas (OO) and osteoblastomas (OB) in six different European centres. METHODS: Eighty-seven patients with spinal OO (77) or OB (10) were treated with CT-guided RFA, after three-dimensional CT-guided access planning. Patient's long-term outcome was assessed by clinical examination and questionnaire-based evaluation including 10-point visual analogue scales (VAS) regarding the effect of RFA on severity of pain and limitations of daily activities. Clinical success was defined as a reduction of > 30% in the VAS score and patient's satisfaction. RESULTS: Overall, RFA was technically successful in 82/87 cases (94.3%) with no major complications; clinical success was achieved in 78/87 cases (89.7%). The OO/OB were localized in the cervical (n = 9/3), the thoracic (n = 27/1), the lumbar (n = 29/4), and the sacral spine (n = 12/2). A decrease in severity of pain after RFA was observed in 86/87 patients (98.9%) with a persistent mean reduction of overall pain score from 8.04 ± 0.96 to 1.46 ± 1.95 (p < 0.001) after a median follow-up time of 29.35 ± 35.59 months. VAS scores significantly decreased for limitations of both daily (5.70 ± 2.73 to 0.67 ± 1.61, p < 0.001) and sports activities (6.40 ± 2.58 to 0.67 ± 1.61, p < 0.001). CONCLUSION: In a multicentric setting, this trial proves RFA to be a safe and efficient method to treat spinal OO/OB and should be regarded as first-line therapy after interdisciplinary case discussion.


Assuntos
Ablação por Cateter , Osteoblastoma/cirurgia , Osteoma Osteoide/cirurgia , Neoplasias da Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador , Adolescente , Adulto , Criança , Pré-Escolar , Estudos de Coortes , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoblastoma/diagnóstico por imagem , Osteoma Osteoide/diagnóstico por imagem , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
10.
BMC Musculoskelet Disord ; 20(1): 357, 2019 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-31387574

RESUMO

BACKGROUND: Scaphoid fractures are the most common carpal fractures. They often need to be treated by surgery, where the use of a compression screw is the globally accepted gold standard. Surgeons may choose between different implant materials including titanium alloys, which remain in the body or are removed after healing. An alternative are biodegradable magnesium-based implants. Properties of magnesium alloys include high stability, osteoconductivity, potential reduction of infections and few artifacts in magnetic resonance imaging (MRI). The aim of this trial is to demonstrate non-inferiority of magnesium-based compression screws compared with titanium Herbert screws for scaphoid fractures. METHODS: The trial is designed as a multicenter, blinded observer, randomized controlled parallel two-group post market trial. Approximately 190 patients will be randomized (1:1) with stratification by center either to titanium or magnesium-based compression screws. Follow-up is 1 year per patient. Surgical procedures and aftercare will be performed according to the German treatment guideline for scaphoid fractures. The first primary endpoint is the patient-rated wrist evaluation (PRWE) score after 6 months. The second primary endpoint is a composite safety endpoint including bone union until 6 months, no adverse device effect (ADE) during surgery or wound healing and no serious ADE or reoperation within 1 year. The third primary endpoint is the difference in change MRI artifacts over time. Non-inferiority will be investigated for primary endpoints 1 (t-test confidence interval) and 2 (Wilson's score interval) using both the full analysis set (FAS) and the per protocol population at the one-sided 2.5% test-level. Superiority of magnesium over titanium screws will be established using the FAS at the two-sided 5% test-level (Welch test) only if non-inferiority has been established for both primary endpoints. Secondary endpoints include quality of life. DISCUSSION: This study will inform care providers whether biodegradable magnesium-based implants are non-inferior to standard titanium Herbert screws for the treatment of scaphoid fractures in terms of wrist function and safety. Furthermore, superiority of magnesium-based implants may be demonstrated using MRI, which is used as surrogate endpoint for screw degradation. TRIAL REGISTRATION: DRKS, DRKS00013368 . Registered Dec 04, 2017.


Assuntos
Implantes Absorvíveis/efeitos adversos , Parafusos Ósseos/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Osso Escafoide/lesões , Traumatismos do Punho/cirurgia , Adolescente , Adulto , Ensaios Clínicos Fase IV como Assunto , Estudos de Equivalência como Asunto , Fixação Interna de Fraturas/efeitos adversos , Humanos , Magnésio/efeitos adversos , Imageamento por Ressonância Magnética , Masculino , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Reoperação/estatística & dados numéricos , Osso Escafoide/diagnóstico por imagem , Osso Escafoide/cirurgia , Titânio/efeitos adversos , Resultado do Tratamento , Traumatismos do Punho/diagnóstico por imagem , Traumatismos do Punho/fisiopatologia , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/fisiopatologia , Adulto Jovem
11.
J Orthop Sci ; 23(2): 321-327, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29174422

RESUMO

BACKGROUND: For the treatment of hallux valgus commonly distal metatarsal osteotomies are performed. Persistent problems due to the hardware and the necessity of hardware removal has led to the development of absorbable implants. To overcome the limitations of formerly used materials for biodegradable implants, recently magnesium has been introduced as a novel implant material. This is the first study showing mid-term clinical and radiological (MRI) data after using magnesium implants for fixation of distal metatarsal osteotomies. MATERIAL AND METHODS: 26 patients with symptomatic hallux valgus were included in the study. They were randomly selected to be treated with a magnesium or standard titanium screw for fixation of a modified distal metatarsal osteotomy. The patients had a standardized clinical follow up and MRI investigation 3 years' post-surgery. The clinical tests included the range of motion of the MTP 1, the AOFAS, FAAM and SF-36 scores. Further on the pain was evaluated on a VAS. RESULTS: Eight patients of the magnesium group and 6 of the titanium group had a full clinical and MRI follow up 3 years postoperatively. One patient was lost to follow-up. All other patients could be interviewed, but denied full study participation. There was a significant improvement for all tested clinical scores (AOFAS, SF-36, FAAM, Pain-NRS) from pre-to postoperative investigation, but no statistically relevant difference between the groups. Magnesium implants showed significantly less artifacts in the MRI, no implant related cysts were found and the implant was under degradation three years postoperatively. CONCLUSION: In this study, bioabsorbable magnesium implants showed comparable clinical results to titanium standard implants 3 years after distal modified metatarsal osteotomy and were more suitable for radiologic analysis. LEVEL OF EVIDENCE: 2.


Assuntos
Implantes Absorvíveis , Parafusos Ósseos , Hallux Valgus/cirurgia , Magnésio/química , Osteotomia/instrumentação , Titânio/química , Adulto , Idoso , Feminino , Seguimentos , Hallux Valgus/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Ossos do Metatarso/cirurgia , Pessoa de Meia-Idade , Variações Dependentes do Observador , Osteotomia/métodos , Amplitude de Movimento Articular/fisiologia , Medição de Risco , Estatísticas não Paramétricas , Fatores de Tempo , Resultado do Tratamento
12.
Eur Radiol ; 27(10): 4345-4350, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28289946

RESUMO

OBJECTIVES: We aimed to evaluate the involvement of extensor tendon sheaths in a large MDCT study group of patients with distal intra-articular radial fractures using the floating fat sign. METHODS: 603 MDCT scans of patients with acute intra-articular distal radial fractures (Frykman III-VIII) acquired between January 2005 and October 2011 were analysed in consensus by two radiologists. The extensor tendon sheath involvement was assessed for each extensor tendon compartment and visually graded from 0 to 2 based on the amount of fat-fluid levels. RESULTS: Extensor tendon sheath involvement with fat-fluid levels was observed in 71.0% of the distal radial fractures, mainly in the second or third compartment. The frequency and degree of tendon sheath involvement was not related to the fracture severity. There was no statistically significant difference in the frequency of tendon effusion between the CT scans acquired before or after closed reduction. CONCLUSION: Traumatic rupture of the extensor tendon sheaths with concomitant fatty effusion is a common finding in patients with distal intra-articular radial fractures. KEY POINTS: • Fat effusions in tendon sheaths are frequent in distal intra-articular radial fractures. • Fat effusions in tendon sheaths are caused by traumatic bone marrow spilling. • Effusions typically involve the second and third compartment simultaneously.


Assuntos
Tomografia Computadorizada Multidetectores , Fraturas do Rádio/diagnóstico por imagem , Traumatismos dos Tendões/diagnóstico por imagem , Traumatismos do Punho/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas do Rádio/complicações , Estudos Retrospectivos , Ruptura/complicações , Ruptura/diagnóstico por imagem , Traumatismos dos Tendões/complicações , Traumatismos do Punho/complicações , Adulto Jovem
13.
BMC Med Imaging ; 17(1): 16, 2017 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-28196474

RESUMO

BACKGROUND: Magnesium alloys have recently been rediscovered as biodegradable implants in musculoskeletal surgery. This study is an ex-vivo trial to evaluate the imaging characteristics of magnesium implants in different imaging modalities as compared to conventional metallic implants. METHODS: A CE-approved magnesium Herbert screw (MAGNEZIX®) and a titanium screw of the same dimensions (3.2x20 mm) were imaged using different modalities: digital radiography (DX), multidetector computed tomography (MDCT), high resolution flat panel CT (FPCT) and magnetic resonance imaging (MRI). The screws were scanned in vitro and after implantation in a fresh chicken tibia in order to simulate surrounding bone and soft tissue. The images were quantitatively evaluated with respect to the overall image quality and the extent and intensity of artifacts. RESULTS: In all modalities, the artifacts generated by the magnesium screw had a lesser extent and were less severe as compared to the titanium screw (mean difference of artifact size of solo scanned screws in DX: 0.7 mm, MDCT: 6.2 mm, FPCT: 5.9 mm and MRI: 4.73 mm; p < 0.05). In MDCT and FPCT multiplanar reformations and 3D reconstructions were superior as compared with the titanium screw and the metal-bone interface after implanting the screws in chicken cadavers was more clearly depicted. While the artifacts of the titanium screw could be effectively reduced using metal-artifact reduction sequences in MRI (WARP, mean reduction of 2.5 mm, p < 0.05), there was no significant difference for the magnesium screw. CONCLUSIONS: Magnesium implants generate significantly less artifacts in common imaging modalities (DX, MDCT, FPCT and MRI) as compared with conventional titanium implants and therefore may facilitate post-operative follow-up.


Assuntos
Implantes Absorvíveis , Artefatos , Parafusos Ósseos , Magnésio , Imageamento por Ressonância Magnética/métodos , Titânio , Tomografia Computadorizada por Raios X/métodos , Animais , Galinhas , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Filme para Raios X
14.
J Vasc Interv Radiol ; 27(3): 361-8.e2, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26803575

RESUMO

PURPOSE: To compare the depiction of pulmonary arteries in pulmonary arterial catheter-based contrast-enhanced cone-beam CT with peripheral intravenous contrast-enhanced multidetector CT in patients with suspected chronic thromboembolic pulmonary hypertension. MATERIAL AND METHODS: In 20 patients (15 men and 5 women, 63.4 y ± 16.3), cone-beam CT using a catheter placed in the main pulmonary artery and 64-row multidetector CT using an appropriate venous access were performed. Contrast enhancement was measured in the main pulmonary artery, the right and left pulmonary arteries, and the left atrium. The amount of peripheral vessel conspicuity adjacent to the pleural surface (distance from vessel-to pleura) was measured. Two readers (R1, R2) independently evaluated the pulmonary arteries for image quality and pathologic findings in both modalities. RESULTS: Contrast density was higher in the main pulmonary artery and right and left pulmonary arteries (P < .002) and lower in the left atrium (P = .001) on cone-beam CT. The smallest distance between clearly delineated vessels and the pleura was significantly lower on cone-beam CT images (P < .0001). Interobserver agreement was good for cone-beam CT (κ = 0.79) and multidetector CT (κ = 0.78), whereas intermodality agreement was moderate (R1, κ = 0.60; R2, κ = 0.59). Both readers detected more weblike stenoses with cone-beam CT (76; 22%) compared with multidetector CT (25; 7%). CONCLUSIONS: Cone-beam CT shows improved contrast between pulmonary arteries and the left atrium and allows a more detailed depiction of the pulmonary arteries.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada de Feixe Cônico , Hipertensão Pulmonar/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Meios de Contraste/administração & dosagem , Feminino , Humanos , Hipertensão Pulmonar/etiologia , Infusões Intravenosas , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Iopamidol/administração & dosagem , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Embolia Pulmonar/complicações
15.
BMC Med Imaging ; 14: 16, 2014 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-24885665

RESUMO

BACKGROUND: Magnetic resonance cholangiopancreatography (MRCP) is an established technique for the evaluation of intra- and extrahepatic bile ducts in patients with known or suspected hepatobiliary disease. However, the ideal acquisition and reconstruction plane for optimal bile duct evaluation with 3D technique has not been evaluated. The purpose of our study was to compare different acquisition and reconstruction planes of 3D-MRCP for bile duct assessment. METHODS: 34 patients (17f/17 m, mean age 41y) referred for MRCP were included in this prospective IRB-approved study. Respiratory-triggered 3D-T2w-MRCP sequences were acquired in coronal and axial plane. Coronal and axial MIP were reconstructed based on each dataset (resulting in two coronal and two axial MIP, respectively). Three readers in two sessions independently assessed the MIP, regarding visualization of bile ducts and image quality. Results were compared (Wilcoxon test). Intra- and interobserver variability were calculated (kappa-statistic). RESULTS: In case of coronal data acquisition, visualization of bile duct segments was significantly better on coronal reconstructed MIP images as compared to axial reconstructed MIP (p < 0.05). Regarding visualization, coronal MIP of the coronal acquisition were equal to coronal MIP of the axial acquisition (p > 0.05). Image quality of coronal and axial datasets did not differ significantly. Intra- and interobserver agreement regarding bile duct visualization were moderate to excellent (κ-range 0.55-1.00 and 0.42-0.85, respectively). CONCLUSIONS: The results of our study suggest that for visualization and evaluation of intra- and extrahepatic bile duct segments reconstructed images in coronal orientation are preferable. The orientation of the primary dataset (coronal or axial) is negligible.


Assuntos
Ductos Biliares Extra-Hepáticos/diagnóstico por imagem , Ductos Biliares Intra-Hepáticos/diagnóstico por imagem , Colangiopancreatografia por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Adulto Jovem
16.
BMC Med Imaging ; 13: 25, 2013 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-23924063

RESUMO

BACKGROUND: To investigate the imaging features of primary sarcomas of the great vessels in CT, MRI and (18)F-FDG PET/CT. METHODS: Thirteen patients with a primary sarcoma of the great vessels were retrospectively evaluated. All available images studies including F-18 FDG PET(/CT) (n = 4), MDCT (n = 12) and MRI (n = 6) were evaluated and indicative image features of this rare tumor entity were identified. RESULTS: The median interval between the first imaging study and the final diagnosis was 11 weeks (0-12 weeks). The most frequently observed imaging findings suggestive of malignant disease in patients with sarcomas of the pulmonary arteries were a large filling defect with vascular distension, unilaterality and a lack of improvement despite effective anticoagulation. In patients with aortic sarcomas we most frequently observed a pedunculated appearance and an atypical location of the filling defect. The F-18 FDG PET(/CT) examinations demonstrated an unequivocal hypermetabolism of the lesion in all cases (4/4). MRI proved lesion vascularization in 5/6 cases. CONCLUSION: Intravascular unilateral or atypically located filling defects of the great vessels with vascular distension, a pedunculated shape and lack of improvement despite effective anticoagulation are suspicious for primary sarcoma on MDCT or MRI. MR perfusion techniques can add information on the nature of the lesion but the findings may be subtle and equivocal. F-18 FDG PET/CT may have a potential role in these patients and may be considered as part of the imaging workup.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Sarcoma/irrigação sanguínea , Sarcoma/patologia , Idoso , Feminino , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/métodos
17.
Rofo ; 195(8): 713-719, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37160146

RESUMO

PURPOSE: Radiology reports mostly contain free-text, which makes it challenging to obtain structured data. Natural language processing (NLP) techniques transform free-text reports into machine-readable document vectors that are important for creating reliable, scalable methods for data analysis. The aim of this study is to classify unstructured radiograph reports according to fractures of the distal fibula and to find the best text mining method. MATERIALS & METHODS: We established a novel German language report dataset: a designated search engine was used to identify radiographs of the ankle and the reports were manually labeled according to fractures of the distal fibula. This data was used to establish a machine learning pipeline, which implemented the text representation methods bag-of-words (BOW), term frequency-inverse document frequency (TF-IDF), principal component analysis (PCA), non-negative matrix factorization (NMF), latent Dirichlet allocation (LDA), and document embedding (doc2vec). The extracted document vectors were used to train neural networks (NN), support vector machines (SVM), and logistic regression (LR) to recognize distal fibula fractures. The results were compared via cross-tabulations of the accuracy (acc) and area under the curve (AUC). RESULTS: In total, 3268 radiograph reports were included, of which 1076 described a fracture of the distal fibula. Comparison of the text representation methods showed that BOW achieved the best results (AUC = 0.98; acc = 0.97), followed by TF-IDF (AUC = 0.97; acc = 0.96), NMF (AUC = 0.93; acc = 0.92), PCA (AUC = 0.92; acc = 0.9), LDA (AUC = 0.91; acc = 0.89) and doc2vec (AUC = 0.9; acc = 0.88). When comparing the different classifiers, NN (AUC = 0,91) proved to be superior to SVM (AUC = 0,87) and LR (AUC = 0,85). CONCLUSION: An automated classification of unstructured reports of radiographs of the ankle can reliably detect findings of fractures of the distal fibula. A particularly suitable feature extraction method is the BOW model. KEY POINTS: · The aim was to classify unstructured radiograph reports according to distal fibula fractures.. · Our automated classification system can reliably detect fractures of the distal fibula.. · A particularly suitable feature extraction method is the BOW model.. CITATION FORMAT: · Dewald CL, Balandis A, Becker LS et al. Automated Classification of Free-Text Radiology Reports: Using Different Feature Extraction Methods to Identify Fractures of the Distal Fibula. Fortschr Röntgenstr 2023; 195: 713 - 719.


Assuntos
Fíbula , Radiologia , Fíbula/diagnóstico por imagem , Radiografia , Algoritmos , Aprendizado de Máquina , Processamento de Linguagem Natural , Radiologia/métodos
18.
BMC Med Imaging ; 12: 21, 2012 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-22828359

RESUMO

BACKGROUND: Living donor liver transplantation (LDLT) is a valuable and legitimate treatment for patients with end-stage liver disease. Computed tomography (CT) has proven to be an important tool in the process of donor evaluation. The purpose of this study was to evaluate the significance of CT in the donor selection process. METHODS: Between May 1999 and October 2010 170 candidate donors underwent biphasic CT. We retrospectively reviewed the results of the CT and liver volumetry, and assessed reasons for rejection. RESULTS: 89 candidates underwent partial liver resection (52.4%). Based on the results of liver CT and volumetry 22 candidates were excluded as donors (31% of the cases). Reasons included fatty liver (n = 9), vascular anatomical variants (n = 4), incidental finding of hemangioma and focal nodular hyperplasia (n = 1) and small (n = 5) or large for size (n = 5) graft volume. CONCLUSION: CT based imaging of the liver in combination with dedicated software plays a key role in the process of evaluation of candidates for LDLT. It may account for up to 1/3 of the contraindications for LDLT.


Assuntos
Seleção do Doador/estatística & dados numéricos , Hepatopatias/diagnóstico por imagem , Hepatopatias/epidemiologia , Transplante de Fígado/diagnóstico por imagem , Transplante de Fígado/estatística & dados numéricos , Doadores Vivos/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adolescente , Adulto , Idoso , Seleção do Doador/métodos , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
19.
Int J Comput Assist Radiol Surg ; 17(10): 1837-1843, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35816271

RESUMO

PURPOSE: Cochlea implant surgery with proper positioning of the cochlear electrode can be challenging. Intraoperative real-time hybrid laser-fluoroscopic-guided navigation based on a multiplanar cone beam computed tomography (CBCT) dataset opens up the opportunity to immediate radiological control of primary electrode misalignments and offering new insights into the cochlea electrode insertion routes and favorable cochlear implant-insertion angle. METHODS: In this retrospective study, 50 cases (29 males, 18 females) of conventional electrode implantation (without intraoperative image control; group A) and nine cases (7 males, 2 females) of CBCT-laser-fluoroscopic-guided surgery (group B) were included in the present study. CBCT-laser-guided surgery under real-time fluoroscopic control was conducted using an intraoperative C-arm CBCT. All patients received preoperative cross-sectional imaging (CT and MRI), in which cochlear malformation could be excluded. Postoperatively, we looked for electrode misplacements. RESULTS: In group A, electrode misalignment was detected postoperatively in 14 of 50 cases (28.0%). In group B, primary electrode misalignment was detected intraoperatively in two patients (22.2%). In both patients, the misalignments were corrected in the same session. The comparison of cochlear insertion angles showed significant differences. Group A: 47.5 ± 2.6° (actual conventional surgery) vs 17.6 ± 2.8° (theoretical CBCT-laser-fluoroscopic-guided surgery) P < 0.001. Group A vs group B: 47.5 ± 2.6° (actual conventional surgery; Group A) vs 17.9 ± 2.5° (actual CBCT-laser-fluoroscopic-guided surgery; Group B) P < 0.001. CONCLUSION: We consider that an intraoperative hybrid CBCT-laser-fluoroscopic-controlled approach in cochlear implant surgery using a C-arm CT can be beneficial, because electrode misalignments can be reduced and if it does occur, remedied in the same surgical session.


Assuntos
Implante Coclear , Implantes Cocleares , Cóclea/cirurgia , Implante Coclear/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Humanos , Lasers , Masculino , Estudos Retrospectivos
20.
PLoS One ; 17(1): e0262758, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35051221

RESUMO

BACKGROUND AND PURPOSE: The complex anatomy of the temporal bone is difficult to understand and constitutes a challenge in the daily diagnostic routine even for experienced neuroradiologists. In the context of otoneurological (oVEMP) and preoperative diagnostics, the diagnosis of superior semicircular canal dehiscence (SSCD) is of great importance for Ear, Nose, and Throat (ENT) specialists. The gold standard for this diagnosis is a high-resolution CT (HRCT) of the temporal bone. In order to correctly diagnose SSCD, special oblique reconstructions are necessary in addition to standard (axial, coronal, sagittal) reconstructions. We evaluated the frequency of diagnosis and its location in HRCT in correlation with otoneurological examination. From this analysis, we present a new SSCD classification. This classification yields the potential of a differentiated analysis of the patient's clinical symptoms with correlation to the cross-sectional anatomy and may lead to a differentiated therapy approach. STUDY DESIGN AND SETTING: We evaluated 1370 temporal bone scans of patients with residual hearing and verified 343 superior semicircular canal dehiscence (SSCD). We conducted a subgroup analysis of these 343 HRCT scans displaying a SSCD and used them as a basis to create a classification. RESULTS: Three location types of SSCD were identified. These were anterior type 1, superior type 2 and posterior type 3. Type 2 were significantly more frequent in both sexes. SSCD at this location can be overlooked if diagnosis is performed only in the standard axial plane, since it can only be visualized by means of double oblique reconstruction. We present a standardized reconstruction algorithm. CONCLUSION: In total, three types of SSCD with differing incidences can be extrapolated from the locations. Superior type 2 is the most frequent one. Both sexes are affected with roughly equal incidence. The use of standardized double oblique reconstruction algorithm ensures that all three types are diagnosed in the HRCT.


Assuntos
Deiscência do Canal Semicircular/diagnóstico por imagem , Osso Temporal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA