Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Toxicol In Vitro ; 49: 90-98, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28941583

RESUMO

Assessment of ocular irritation is a regulatory requirement in safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as stand-alone assays. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed to assess the reliability of eight in vitro test methods and computational models as well as establishing an optimal tiered-testing strategy. For three computational models (Toxtree, and Case Ultra EYE_DRAIZE and EYE_IRR) performance parameters were calculated. Coverage ranged from 15 to 58%. Coverage was 2 to 3.4 times higher for liquids than for solids. The lowest number of false positives (5%) was reached with EYE_IRR; this model however also gave a high number of false negatives (46%). The lowest number of false negatives (25%) was seen with Toxtree; for liquids Toxtree predicted the lowest number of false negatives (11%), for solids EYE_DRAIZE did (17%). It can be concluded that the training sets should be enlarged with high quality data. The tested models are not yet sufficiently powerful for stand-alone evaluations, but that they can surely become of value in an integrated weight-of-evidence approach in hazard assessment.


Assuntos
Olho/efeitos dos fármacos , Irritantes/classificação , Irritantes/toxicidade , Modelos Biológicos , Animais , Simulação por Computador , Relação Quantitativa Estrutura-Atividade , Coelhos , Testes de Toxicidade
2.
Toxicol In Vitro ; 49: 2-5, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28629855

RESUMO

The main objective of the CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project (2015-2016) was to develop tiered, non-animal testing strategies for serious eye damage and eye irritation assessment in relation to the most important drivers of classification. The serious eye damage and eye irritation potential of a set of 80 chemicals was identified based on existing in vivo Draize eye test data and testing was conducted using the following eight alternative test methods: BCOP (Bovine Corneal Opacity and Permeability)+histopathology, BCOP-LLBO (BCOP Laser Light-Based Opacitometer), ICE (Isolated Chicken Eye)+histopathology, STE (Short Term Exposure), EpiOcular™ EIT (EpiOcular Eye Irritation Test), EpiOcular™ ET-50 (EpiOcular™ Time-to-toxicity), SkinEthic™ HCE EIT (SkinEthic™ Human Corneal Epithelial Eye Irritation Test), and SMI (Slug Mucosal Irritation). Project management decided to not include the ICE data in this project since the execution showed relevant, and not predictable, deviations from Organisation for Economic Co-operation and Development (OECD) Test Guideline (TG) 438 and Guidance Document 160. At this stage, the outcome of these deviations has not been fully assessed. In addition to these alternative test methods, the computational models Toxtree and Case Ultra were taken into account. This project assessed the relevance of these test methods, their applicability domains and limitations in terms of 'drivers of classification', and their strengths and weaknesses. In this way, methods were identified that fit into a tiered-testing strategy for serious eye damage/eye irritation assessment to distinguish United Nations Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS) Category 1 (Cat 1) chemicals from non-Cat 1 chemicals and address the gap namely distinguish between Category 2 (Cat 2) and Cat 1 chemicals.


Assuntos
Olho/efeitos dos fármacos , Irritantes/classificação , Irritantes/toxicidade , Testes de Toxicidade/métodos , Animais , União Europeia , Humanos , Organização para a Cooperação e Desenvolvimento Econômico , Nações Unidas
3.
Toxicol In Vitro ; 49: 34-52, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28866024

RESUMO

Assessment of acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. The objective of the CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for eye irritation assessment for all drivers of classification. A set of 80 reference chemicals (38 liquids and 42 solids) was tested with eight different alternative methods. Here, the results obtained with reconstructed human cornea-like epithelium (RhCE) EpiOcular™ in the EpiOcular time-to-toxicity Tests (Neat and Dilution ET-50 protocols) are presented. The primary aim of this study was to evaluate whether test methods can discriminate chemicals not requiring classification for serious eye damage/eye irritancy (No Category) from chemicals requiring classification and labelling for Category 1 and Category 2. In addition, the predictive capacity in terms of in vivo drivers of classification was investigated. The chemicals were tested in two independent runs by MatTek In Vitro Life Science Laboratories. Results of this study demonstrate very high specificity of both test protocols. With the existing prediction models described in the SOPs, the specificity of the Neat and Dilution method was 87% and 100%, respectively. The Dilution method was able to correctly predicting 66% of GHS Cat 2 chemicals, however, prediction of GHS Cat 1 chemicals was only 47%-55% using the current protocols. In order to achieve optimal prediction for all three classes, a testing strategy was developed which combines the most predictive time-points of both protocols and for tests liquids and solids separately. Using this new testing strategy, the sensitivity for predicting GHS Cat 1 and GHS Cat 2 chemicals was 73% and 64%, respectively and the very high specificity of 97% was maintained. None of the Cat 1 chemicals was underpredicted as GHS No Category. Further combination of the EpiOcular time-to-toxicity protocols with other validated in vitro systems evaluated in this project, should enable significant reduction and even possible replacement of the animal tests for the final assessment of the irritation potential in all of the GHS classes.


Assuntos
Olho/efeitos dos fármacos , Irritantes/classificação , Irritantes/toxicidade , Testes de Toxicidade/métodos , Alternativas aos Testes com Animais , Opacidade da Córnea/induzido quimicamente , Humanos , Reprodutibilidade dos Testes
4.
Toxicol In Vitro ; 49: 99-115, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28964898

RESUMO

Assessment of acute eye irritation potential is part of the international regulatory requirements for safety testing of chemicals. In the last decades, many efforts have been made in the search for alternative methods to replace the regulatory in vivo Draize rabbit eye test (OECD TG 405). Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. The main objective of the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for serious eye damage and eye irritation assessment that can lead to complete replacement of OECD TG 405. A set of 80 reference chemicals (e.g. balanced by important driver of classification and physical state), was tested with seven test methods. Based on the results of this project, three different strategies were suggested. We have provided a standalone (EpiOcular ET-50), a two-tiered and three-tiered strategy, that can be used to distinguish between Cat 1 and Cat 2 chemicals and chemicals that do not require classification (No Cat). The two-tiered and three-tiered strategies use an RhCE test method (EpiOcular EIT or SkinEthic™ EIT) at the bottom (identification No Cat) in combination with the BCOP LLBO (two-tiered strategy) or BCOP OP-KIT and SMI (three-tiered strategy) at the top (identification Cat 1). For our proposed strategies, 71.1% - 82.9% Cat 1, 64.2% - 68.5% Cat 2 and ≥80% No Cat chemicals were correctly identified. Also, similar results were obtained for the Top-Down and Bottom-Up approach.


Assuntos
Olho/efeitos dos fármacos , Irritantes/classificação , Irritantes/toxicidade , Testes de Toxicidade/métodos , Animais , Bovinos , Gastrópodes , Humanos
5.
Toxicol In Vitro ; 49: 77-89, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28870540

RESUMO

Assessment of ocular irritancy is an international regulatory requirement in the safety evaluation of industrial and consumer products. Although many in vitro ocular irritation assays exist, alone they are incapable of fully categorizing chemicals. The objective of CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for eye irritation assessment that can lead to complete replacement of the in vivo Draize rabbit eye test (OECD TG 405). A set of 80 reference chemicals was tested with seven test methods, one method was the Slug Mucosal Irritation (SMI) test method. The method measures the amount of mucus produced (MP) during a single 1-hour contact with a 1% and 10% dilution of the chemical. Based on the total MP, a classification (Cat 1, Cat 2, or No Cat) is predicted. The SMI test method correctly identified 65.8% of the Cat 1 chemicals with a specificity of 90.5% (low over-prediction rate for in vivo Cat 2 and No Cat chemicals). Mispredictions were predominantly unidirectional towards lower classifications with 26.7% of the liquids and 40% of the solids being underpredicted. In general, the performance was better for liquids than for solids with respectively 76.5% vs 57.1% (Cat 1), 61.5% vs 50% (Cat 2), and 87.5% vs 85.7% (No Cat) being identified correctly.


Assuntos
Olho/efeitos dos fármacos , Gastrópodes , Irritantes/classificação , Irritantes/toxicidade , Mucosa/efeitos dos fármacos , Testes de Toxicidade/métodos , Animais
6.
Toxicol In Vitro ; 49: 21-33, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28697962

RESUMO

Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. The objective of the CON4EI project was to develop tiered testing strategies for eye irritation assessment. A set of 80 reference chemicals (38 liquids and 42 solids) was tested with eight different methods. Here, the results obtained with the EpiOcular™ Eye Irritation Test (EIT), adopted as OECD TG 492, are shown. The primary aim of this study was to evaluate of the performance of the test method to discriminate between chemicals not requiring classification for serious eye damage/eye irritancy (No Category) and chemicals requiring classification and labelling. In addition, the predictive capacity in terms of in vivo drivers of classification (i.e. corneal opacity, conjunctival redness and persistence at day 21) was investigated. EpiOcular™ EIT achieved a sensitivity of 97%, a specificity of 87% and accuracy of 95% and also confirmed its excellent reproducibility (100%) from the original validation. The assay was applicable to all chemical categories tested in this project and its performance was not limited to the particular driver of the classification. In addition to the existing prediction model for dichotomous categorization, a new prediction model for Cat 1 is suggested.


Assuntos
Olho/efeitos dos fármacos , Irritantes/classificação , Irritantes/toxicidade , Testes de Toxicidade/métodos , Alternativas aos Testes com Animais , Opacidade da Córnea/induzido quimicamente , Humanos , Reprodutibilidade dos Testes
7.
Toxicol In Vitro ; 49: 65-76, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28801046

RESUMO

Assessment of ocular irritancy is an international regulatory requirement in the safety evaluation of industrial and consumer products. Although many in vitro ocular irritation assays exist, alone they are incapable of fully categorizing chemicals. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium was developed to assess the reliability of eight in vitro test methods and establish an optimal tiered-testing strategy. One assay selected was the Short Time Exposure (STE) assay. This assay measures the viability of SIRC rabbit corneal cells after 5min exposure to 5% and 0.05% solutions of test material, and is capable of categorizing of Category 1 and No Category chemicals. The accuracy of the STE test method to identify Cat 1 chemicals was 61.3% with 23.7% sensitivity and 95.2% specificity. If non-soluble chemicals and unqualified results were excluded, the performance to identify Cat 1 chemicals remained similar (accuracy 62.2% with 22.7% sensitivity and 100% specificity). The accuracy of the STE test method to identify No Cat chemicals was 72.5% with 66.2% sensitivity and 100% specificity. Excluding highly volatile chemicals, non-surfactant solids and non-qualified results resulted in an important improvement of the performance of the STE test method (accuracy 96.2% with 81.8% sensitivity and 100% specificity). Furthermore, it seems that solids are more difficult to test in the STE, 71.4% of the solids resulted in unqualified results (solubility issues and/or high variation between independent runs) whereas for liquids 13.2% of the results were not qualified, supporting the restriction of the test method regarding the testing of solids.


Assuntos
Córnea/citologia , Irritantes/classificação , Irritantes/toxicidade , Testes de Toxicidade/métodos , Animais , Sobrevivência Celular/efeitos dos fármacos , Coelhos
8.
Toxicol In Vitro ; 49: 6-10, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29598996

RESUMO

Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. In the past, several prospective and retrospective validation studies have taken place in the area of serious eye damage/eye irritation testing. Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. A very important aspect to ensure development of successful alternative test methods and/or strategies for serious eye damage/eye irritation testing is the selection of appropriate reference chemicals. A set of 80 reference chemicals was selected for the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project, in collaboration with Cosmetics Europe, from the Draize Reference Database published by Cosmetics Europe based on key criteria that were set in their paper (e.g. balanced by important driver of classification and physical state). The most important goals of the CON4EI project were to identify the performance of eight in vitro alternative tests in terms of driver of classification and to identify similarities/differences between the methods in order the build a successful testing strategy that can discriminate between all UN GHS categories. This paper provides background on selection of the test chemicals.

9.
Toxicol In Vitro ; 49: 11-20, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28625465

RESUMO

Assessment of ocular irritancy is an international regulatory requirement and a necessary step in the safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as a stand-alone assay. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed with the goal of assessing the reliability of eight in vitro/alternative test methods as well as establishing an optimal tiered-testing strategy. One of the in vitro assays selected was the validated SkinEthic™ Human Corneal Epithelium Eye Irritation Test method (SkinEthic™ HCE EIT). The SkinEthic™ HCE EIT has already demonstrated its capacity to correctly identify chemicals (both substances and mixtures) not requiring classification and labelling for eye irritation or serious eye damage (No Category). The goal of this study was to evaluate the performance of the SkinEthic™ HCE EIT test method in terms of the important in vivo drivers of classification. For the performance with respect to the drivers all in vivo Cat 1 and No Cat chemicals were 100% correctly identified. For Cat 2 chemicals the liquids and the solids had a sensitivity of 100% and 85.7%, respectively. For the SkinEthic™ HCE EIT test method, 100% concordance in predictions (No Cat versus No prediction can be made) between the two participating laboratories was obtained. The accuracy of the SkinEthic™ HCE EIT was 97.5% with 100% sensitivity and 96.9% specificity. The SkinEthic™ HCE EIT confirms its excellent results of the validation studies.


Assuntos
Epitélio Corneano/efeitos dos fármacos , Irritantes/classificação , Irritantes/toxicidade , Testes de Toxicidade/métodos , Alternativas aos Testes com Animais , Humanos , Reprodutibilidade dos Testes
10.
Toxicol In Vitro ; 49: 53-64, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29598995

RESUMO

Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals.

11.
Toxicol In Vitro ; 44: 44-48, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28595836

RESUMO

Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. In the past, several prospective and retrospective validation studies have taken place in the area of serious eye damage/eye irritation testing. Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. A very important aspect to ensure development of successful alternative test methods and/or strategies for serious eye damage/eye irritation testing is the selection of appropriate reference chemicals. A set of 80 reference chemicals was selected for the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project, in collaboration with Cosmetics Europe, from the Draize Reference Database published by Cosmetics Europe based on key criteria that were set in their paper (e.g. balanced by important driver of classification and physical state). The most important goals of the CON4EI project were to identify the performance of eight in vitro alternative tests in terms of driver of classification and to identify similarities/differences between the methods in order the build a successful testing strategy that can discriminate between all UN GHS categories. This paper provides background on selection of the test chemicals.


Assuntos
Alternativas aos Testes com Animais , Irritantes/classificação , Irritantes/toxicidade , Testes de Toxicidade , Animais , Bases de Dados Factuais , Olho/efeitos dos fármacos , Rotulagem de Produtos , Coelhos
12.
Toxicol In Vitro ; 44: 122-133, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28673559

RESUMO

Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals.


Assuntos
Alternativas aos Testes com Animais , Opacidade da Córnea/induzido quimicamente , Olho/efeitos dos fármacos , Irritantes/classificação , Irritantes/toxicidade , Permeabilidade/efeitos dos fármacos , Animais , Bovinos , Olho/metabolismo , Rotulagem de Produtos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA