1.
Magn Reson Med ; 92(3): 1064-1078, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38726772

RESUMO

PURPOSE: This study aims to develop and evaluate a novel cardiovascular MR sequence, MyoFold, designed for the simultaneous quantifications of myocardial tissue composition and wall motion. METHODS: MyoFold is designed as a 2D single breathing-holding sequence, integrating joint T1/T2 mapping and cine imaging. The sequence uses a 2-fold accelerated balanced SSFP (bSSFP) for data readout and incorporates electrocardiogram synchronization to align with the cardiac cycle. MyoFold initially acquires six single-shot inversion-recovery images, completed during the diastole of six successive heartbeats. T2 preparation (T2-prep) is applied to introduce T2 weightings for the last three images. Subsequently, over the following six heartbeats, segmented bSSFP is performed for the movie of the entire cardiac cycle, synchronized with an electrocardiogram. A neural network trained using numerical simulations of MyoFold is used for T1 and T2 calculations. MyoFold was validated through phantom and in vivo experiments, with comparisons made against MOLLI, SASHA, T2-prep bSSFP, and the conventional cine. RESULTS: In phantom studies, MyoFold exhibited a 10% overestimation in T1 measurements, whereas T2 measurements demonstrated high accuracy. In vivo experiments revealed that MyoFold T1 had comparable accuracy to SASHA and precision similar to MOLLI. MyoFold demonstrated good agreement with T2-prep bSSFP in myocardial T2 measurements. No significant differences were observed in the quantification of left-ventricle wall thickness and function between MyoFold and the conventional cine. CONCLUSION: MyoFold presents as a rapid, simple, and multitasking approach for quantitative cardiovascular MR examinations, offering simultaneous assessment of tissue composition and wall motion. The sequence's multitasking capabilities make it a promising tool for comprehensive cardiac evaluations in clinical settings.


Assuntos
Coração , Imagem Cinética por Ressonância Magnética , Imagens de Fantasmas , Adulto , Feminino , Humanos , Masculino , Algoritmos , Eletrocardiografia , Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio , Reprodutibilidade dos Testes
2.
Magn Reson Med ; 2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39188085

RESUMO

PURPOSE: To develop a reconstruction method for highly accelerated cardiac cine MRI with high spatiotemporal resolution and low temporal blurring, and to demonstrate accurate estimation of ventricular volumes and myocardial strain in healthy subjects and in patients. METHODS: The proposed method, called CineVN, employs a spatiotemporal Variational Network combined with conjugate gradient descent for optimized data consistency and improved image quality. The method is first evaluated on retrospectively undersampled cine MRI data in terms of image quality. Then, prospectively accelerated data are acquired in 18 healthy subjects both segmented over two heartbeats per slice as well as in real time with 1.6 mm isotropic resolution. Ventricular volumes and strain parameters are computed and compared to a compressed sensing reconstruction and to a conventional reference cine MRI acquisition. Lastly, the method is demonstrated in 46 patients and ventricular volumes and strain parameters are evaluated. RESULTS: CineVN outperformed compressed sensing in image quality metrics on retrospectively undersampled data. Functional parameters and myocardial strain were the most accurate for CineVN compared to two state-of-the-art compressed sensing methods. CONCLUSION: Deep learning-based reconstruction using our proposed method enables accurate evaluation of cardiac function in real-time cine MRI with high spatiotemporal resolution. This has the potential to improve cardiac imaging particularly for patients with arrhythmia or impaired breath-hold capability.

3.
NMR Biomed ; 37(4): e5091, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38196195

RESUMO

BACKGROUND: Despite the widespread use of cine MRI for evaluation of cardiac function, existing real-time methods do not easily enable quantification of ventricular function. Moreover, segmented cine MRI assumes periodicity of cardiac motion. We aim to develop a self-gated, cine MRI acquisition scheme with data-driven cluster-based binning of cardiac motion. METHODS: A Cartesian golden-step balanced steady-state free precession sequence with sorted k-space ordering was designed. Image data were acquired with breath-holding. Principal component analysis and k-means clustering were used for binning of cardiac phases. Cluster compactness in the time dimension was assessed using temporal variability, and dispersion in the spatial dimension was assessed using the Calinski-Harabasz index. The proposed and the reference electrocardiogram (ECG)-gated cine methods were compared using a four-point image quality score, SNR and CNR values, and Bland-Altman analyses of ventricular function. RESULTS: A total of 10 subjects with sinus rhythm and 8 subjects with arrhythmias underwent cardiac MRI at 3.0 T. The temporal variability was 45.6 ms (cluster) versus 24.6 ms (ECG-based) (p < 0.001), and the Calinski-Harabasz index was 59.1 ± 9.1 (cluster) versus 22.0 ± 7.1 (ECG based) (p < 0.001). In subjects with sinus rhythm, 100% of the end-systolic and end-diastolic images from both the cluster and reference approach received the highest image quality score of 4. Relative to the reference cine images, the cluster-based multiphase (cine) image quality consistently received a one-point lower score (p < 0.05), whereas the SNR and CNR values were not significantly different (p = 0.20). In cases with arrhythmias, 97.9% of the end-systolic and end-diastolic images from the cluster approach received an image quality score of 3 or more. The mean bias values for biventricular ejection fraction and volumes derived from the cluster approach versus reference cine were negligible. CONCLUSION: ECG-free cine cardiac MRI with data-driven clustering for binning of cardiac motion is feasible and enables quantification of cardiac function.


Assuntos
Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Função Ventricular , Análise por Conglomerados , Reprodutibilidade dos Testes
4.
J Magn Reson Imaging ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38436994

RESUMO

BACKGROUND: Balanced steady-state free precession (bSSFP) imaging is commonly used in cardiac cine MRI but prone to image artifacts. Ferumoxytol-enhanced (FE) gradient echo (GRE) has been proposed as an alternative. Utilizing the abundance of bSSFP images to develop a computationally efficient network that is applicable to FE GRE cine would benefit future network development. PURPOSE: To develop a variable-splitting spatiotemporal network (VSNet) for image reconstruction, trained on bSSFP cine images and applicable to FE GRE cine images. STUDY TYPE: Retrospective and prospective. SUBJECTS: 41 patients (26 female, 53 ± 19 y/o) for network training, 31 patients (19 female, 49 ± 17 y/o) and 5 healthy subjects (5 female, 30 ± 7 y/o) for testing. FIELD STRENGTH/SEQUENCE: 1.5T and 3T, bSSFP and GRE. ASSESSMENT: VSNet was compared to VSNet with total variation loss, compressed sensing and low rank methods for 14× accelerated data. The GRAPPA×2/×3 images served as the reference. Peak signal-to-noise-ratio (PSNR), structural similarity index (SSIM), left ventricular (LV) and right ventricular (RV) end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) were measured. Qualitative image ranking and scoring were independently performed by three readers. Latent scores were calculated based on scores of each method relative to the reference. STATISTICS: Linear mixed-effects regression, Tukey method, Fleiss' Kappa, Bland-Altman analysis, and Bayesian categorical cumulative probit model. A P-value <0.05 was considered statistically significant. RESULTS: VSNet achieved significantly higher PSNR (32.7 ± 0.2), SSIM (0.880 ± 0.004), rank (2.14 ± 0.06), and latent scores (-1.72 ± 0.22) compared to other methods (rank >2.90, latent score < -2.63). Fleiss' Kappa was 0.52 for scoring and 0.61 for ranking. VSNet showed no significantly different LV and RV ESV (P = 0.938) and EF (P = 0.143) measurements, but statistically significant different (2.62 mL) EDV measurements compared to the reference. CONCLUSION: VSNet produced the highest image quality and the most accurate functional measurements for FE GRE cine images among the tested 14× accelerated reconstruction methods. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 1.

5.
Eur Radiol ; 34(2): 1113-1122, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37594524

RESUMO

OBJECTIVES: To evaluate a dynamic half-Fourier acquired single turbo spin echo (HASTE) sequence following anterior cervical discectomy and fusion (ACDF) at the junctional level for adjacent segment degeneration comparing dynamic listhesis to radiographs and assessing dynamic cord contact and deformity during flexion-extension METHODS: Patients with ACDF referred for cervical spine MRI underwent a kinematic flexion-extension sagittal 2D HASTE sequence in addition to routine sequences. Images were independently reviewed by three radiologists for static/dynamic listhesis, and compared to flexion-extension radiographs. Blinded assessment of the HASTE sequence was performed for cord contact/deformity between neutral, flexion, and extension, to evaluate concordance between readers and inter-modality agreement. Inter-reader agreement for dynamic listhesis and impingement grade and inter-modality agreement for dynamic listhesis on MRI and radiographs was assessed using the kappa coefficient and percentage concordance. RESULTS: A total of 28 patients, mean age 60.2 years, were included. Mean HASTE acquisition time was 42 s. 14.3% demonstrated high grade dynamic stenosis (> grade 4) at the adjacent segment. There was substantial agreement for dynamic cord impingement with 70.2% concordance (kappa = 0.62). Concordance across readers for dynamic listhesis using HASTE was 81.0% (68/84) (kappa = 0.16) compared with 71.4% (60/84) (kappa = 0.40) for radiographs. Inter-modality agreement between flexion-extension radiographs and MRI assessment for dynamic listhesis across the readers was moderate (kappa = 0.41; 95% confidence interval: 0.16 to 0.67). CONCLUSIONS: A sagittal flexion-extension HASTE cine sequence provides substantial agreement between readers for dynamic cord deformity and moderate agreement between radiographs and MRI for dynamic listhesis. CLINICAL RELEVANCE STATEMENT: Degeneration of the adjacent segment with instability and myelopathy is one of the most common causes of pain and neurological deterioration requiring re-operation following cervical fusion surgery. KEY POINTS: • A real-time kinematic 2D sagittal HASTE flexion-extension sequence can be used to assess for dynamic listhesis, cervical cord, contact and deformity. • The additional kinematic cine sequence was well tolerated and the mean acquisition time for the 2D HASTE sequence was 42 s (range 31-44 s). • A sagittal flexion-extension HASTE cine sequence provides substantial agreement between readers for dynamic cord deformity and moderate agreement between radiographs and MRI for dynamic listhesis.


Assuntos
Vértebras Cervicais , Fusão Vertebral , Humanos , Pessoa de Meia-Idade , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Vértebras Cervicais/patologia , Fenômenos Biomecânicos , Imageamento por Ressonância Magnética/métodos , Radiografia , Discotomia
6.
Eur Radiol ; 34(8): 4920-4927, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38195730

RESUMO

OBJECTIVES: Assessment of myocardial strain by feature tracking magnetic resonance imaging (FT-MRI) in human fetuses with and without congenital heart disease (CHD) using cardiac Doppler ultrasound (DUS) gating. METHODS: A total of 43 human fetuses (gestational age 28-41 weeks) underwent dynamic cardiac MRI at 3 T. Cine balanced steady-state free-precession imaging was performed using fetal cardiac DUS gating. FT-MRI was analyzed using dedicated post-processing software. Endo- and epicardial contours were manually delineated from fetal cardiac 4-chamber views, followed by automated propagation to calculate global longitudinal strain (GLS) of the left (LV) and right ventricle (RV), LV radial strain, and LV strain rate. RESULTS: Strain assessment was successful in 38/43 fetuses (88%); 23 of them had postnatally confirmed diagnosis of CHD (e.g., coarctation, transposition of great arteries) and 15 were heart healthy. Five fetuses were excluded due to reduced image quality. In fetuses with CHD compared to healthy controls, median LV GLS (- 13.2% vs. - 18.9%; p < 0.007), RV GLS (- 7.9% vs. - 16.2%; p < 0.006), and LV strain rate (1.4 s-1 vs. 1.6 s-1; p < 0.003) were significantly higher (i.e., less negative). LV radial strain was without a statistically significant difference (20.7% vs. 22.6%; p = 0.1). Bivariate discriminant analysis for LV GLS and RV GLS revealed a sensitivity of 67% and specificity of 93% to differentiate between fetuses with CHD and healthy fetuses. CONCLUSION: Myocardial strain was successfully assessed in the human fetus, performing dynamic fetal cardiac MRI with DUS gating. Our study indicates that strain parameters may allow for differentiation between fetuses with and without CHD. CLINICAL RELEVANCE STATEMENT: Myocardial strain analysis by cardiac MRI with Doppler ultrasound gating and feature tracking may provide a new diagnostic approach for evaluation of fetal cardiac function in congenital heart disease. KEY POINTS: • MRI myocardial strain analysis has not been performed in human fetuses so far. • Myocardial strain was assessed in human fetuses using cardiac MRI with Doppler ultrasound gating. • MRI myocardial strain may provide a new diagnostic approach to evaluate fetal cardiac function.


Assuntos
Coração Fetal , Cardiopatias Congênitas , Humanos , Feminino , Gravidez , Cardiopatias Congênitas/diagnóstico por imagem , Coração Fetal/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Técnicas de Imagem de Sincronização Cardíaca/métodos
7.
Eur Radiol ; 34(9): 5691-5704, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38451322

RESUMO

OBJECTIVE: This work aimed to derive a machine learning (ML) model for the differentiation between ischemic cardiomyopathy (ICM) and non-ischemic cardiomyopathy (NICM) on non-contrast cardiovascular magnetic resonance (CMR). METHODS: This retrospective study evaluated CMR scans of 107 consecutive patients (49 ICM, 58 NICM), including atrial and ventricular strain parameters. We used these data to compare an explainable tree-based gradient boosting additive model with four traditional ML models for the differentiation of ICM and NICM. The models were trained and internally validated with repeated cross-validation according to discrimination and calibration. Furthermore, we examined important variables for distinguishing between ICM and NICM. RESULTS: A total of 107 patients and 38 variables were available for the analysis. Of those, 49 were ICM (34 males, mean age 60 ± 9 years) and 58 patients were NICM (38 males, mean age 56 ± 19 years). After 10 repetitions of the tenfold cross-validation, the proposed model achieved the highest area under curve (0.82, 95% CI [0.47-1.00]) and lowest Brier score (0.19, 95% CI [0.13-0.27]), showing competitive diagnostic accuracy and calibration. At the Youden's index, sensitivity was 0.72 (95% CI [0.68-0.76]), the highest of all. Analysis of predictions revealed that both atrial and ventricular strain CMR parameters were important for the identification of ICM patients. CONCLUSION: The current study demonstrated that using a ML model, multi chamber myocardial strain, and function on non-contrast CMR parameters enables the discrimination between ICM and NICM with competitive diagnostic accuracy. CLINICAL RELEVANCE STATEMENT: A machine learning model based on non-contrast cardiovascular magnetic resonance parameters may discriminate between ischemic and non-ischemic cardiomyopathy enabling wider access to cardiovascular magnetic resonance examinations with lower costs and faster imaging acquisition. KEY POINTS: • The exponential growth in cardiovascular magnetic resonance examinations may require faster and more cost-effective protocols. • Artificial intelligence models can be utilized to distinguish between ischemic and non-ischemic etiologies. • Machine learning using non-contrast CMR parameters can effectively distinguish between ischemic and non-ischemic cardiomyopathies.


Assuntos
Cardiomiopatias , Aprendizado de Máquina , Imagem Cinética por Ressonância Magnética , Isquemia Miocárdica , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Cardiomiopatias/diagnóstico por imagem , Estudos Retrospectivos , Isquemia Miocárdica/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Diagnóstico Diferencial , Idoso , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Eur Radiol ; 34(7): 4261-4272, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38114847

RESUMO

OBJECTIVES: To compare cardiac computed tomography (CCT) and cardiac magnetic resonance (CMR) for the quantitative assessment of the left ventricular (LV) trabeculated layer in patients with suspected noncompaction cardiomyopathy (NCCM). MATERIALS AND METHODS: Subjects with LV excessive trabeculation who underwent both CMR and CCT imaging as part of the prospective international multicenter NONCOMPACT clinical study were included. For each subject, short-axis CCT and CMR slices were matched. Four quantitative metrics were estimated: 1D noncompacted-to-compacted ratio (NCC), trabecular-to-myocardial area ratio (TMA), trabecular-to-endocardial cavity area ratio (TCA), and trabecular-to-myocardial volume ratio (TMV). In 20 subjects, end-diastolic and mid-diastolic CCT images were compared for the quantification of the trabeculated layer. Relationships between the metrics were investigated using linear regression models and Bland-Altman analyses. RESULTS: Forty-eight subjects (49.9 ± 12.8 years; 28 female) were included in this study. NCC was moderately correlated (r = 0.62), TMA and TMV were strongly correlated (r = 0.78 and 0.78), and TCA had excellent correlation (r = 0.92) between CMR and CCT, with an underestimation bias from CCT of 0.3 units, and 5.1, 4.8, and 5.4 percent-points for the 4 metrics, respectively. TMA, TCA, and TMV had excellent correlations (r = 0.93, 0.96, 0.94) and low biases (- 3.8, 0.8, - 3.8 percent-points) between the end-diastolic and mid-diastolic CCT images. CONCLUSIONS: TMA, TCA, and TMV metrics of the LV trabeculated layer in patients with suspected NCCM demonstrated high concordance between CCT and CMR images. TMA and TCA were highly reproducible and demonstrated minimal differences between mid-diastolic and end-diastolic CCT images. CLINICAL RELEVANCE STATEMENT: The results indicate similarity of CCT to CMR for quantifying the LV trabeculated layer, and the small differences in quantification between end-diastole and mid-diastole demonstrate the potential for quantifying the LV trabeculated layer from clinically performed coronary CT angiograms. KEY POINTS: • Data on cardiac CT for quantifying the left ventricular trabeculated layer are limited. • Cardiac CT yielded highly reproducible metrics of the left ventricular trabeculated layer that correlated well with metrics defined by cardiac MR. • Cardiac CT appears to be equivalent to cardiac MR for the quantification of the left ventricular trabeculated layer.


Assuntos
Ventrículos do Coração , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Ventrículos do Coração/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Adulto
9.
J Cardiovasc Magn Reson ; : 101089, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39218220

RESUMO

PURPOSE: To apply free-running three-dimensional (3D) cine balanced steady state free precession (bSSFP) CMR framework in combination with AI segmentations to quantify time-resolved aortic displacement, diameter and diameter change. METHODS: In this prospective study, we implemented a free-running 3D cine bSSFP sequence with scan time of about 4minutes facilitated by pseudo-spiral Cartesian undersampling and compressed-sensing reconstruction. Automated segmentation of all cardiac timeframes was applied through the use of nnU-Net. Dynamic 3D motion maps were created for three repeated scans per volunteer, leading to the detailed quantification of motion, as well as the measurement and change in diameter of the ascending aorta. RESULTS: A total of 14 adult healthy volunteers (median age, 28 years (IQR: 26.0-31.3), 6 female) were included. Automated segmentation compared to manual segmentation of the aorta test set showed a Dice score of 0.93 ± 0.02. The median (interquartile range) over all volunteers for the largest maximum and mean ascending aorta (AAo) displacement in the first scan was 13.0 (4.4) mm and 5.6 (2.4) mm, respectively. Peak mean diameter in the AAo was 25.9 (2.2) mm and peak mean diameter change was 1.4 (0.5) mm. The maximum individual variability over the three repeated scans of maximum and mean AAo displacement was 3.9 (1.6) mm and 2.2 (0.8) mm, respectively. The maximum individual variability of mean diameter and diameter change were 1.2 (0.5) mm and 0.9 (0.4) mm. CONCLUSION: A free-running 3D cine bSSFP CMR scan with a scan time of four minutes combined with an automated nnU-net segmentation consistently captured the aorta's cardiac motion-related 4D displacement, diameter, and diameter change.

10.
AJR Am J Roentgenol ; 222(5): e2330272, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38323784

RESUMO

BACKGROUND. Cine cardiac MRI sequences require repeated breath-holds, which can be difficult for patients with ischemic heart disease (IHD). OBJECTIVE. The purpose of the study was to compare a free-breathing accelerated cine sequence using deep learning (DL) reconstruction and a standard breath-hold cine sequence in terms of image quality and left ventricular (LV) measurements in patients with IHD undergoing cardiac MRI. METHODS. This prospective study included patients undergoing 1.5- or 3-T cardiac MRI for evaluation of IHD between March 15, 2023, and June 21, 2023. Examinations included an investigational free-breathing cine short-axis sequence with DL reconstruction (hereafter, cine-DL sequence). Two radiologists (reader 1 [R1] and reader 2 [R2]), in blinded fashion, independently assessed left ventricular ejection fraction (LVEF), left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), and subjective image quality for the cine-DL sequence and a standard breath-hold balanced SSFP sequence; R1 assessed artifacts. RESULTS. The analysis included 26 patients (mean age, 64.3 ± 11.7 [SD] years; 14 men, 12 women). Acquisition was shorter for the cine-DL sequence than the standard sequence (mean ± SD, 0.6 ± 0.1 vs 2.4 ± 0.6 minutes; p < .001). The cine-DL sequence, in comparison with the standard sequence, showed no significant difference for LVEF for R1 (mean ± SD, 51.7% ± 14.3% vs 51.3% ± 14.7%; p = .56) or R2 (53.4% ± 14.9% vs 52.8% ± 14.6%; p = .53); significantly greater LVEDV for R2 (mean ± SD, 171.9 ± 51.9 vs 160.6 ± 49.4 mL; p = .01) but not R1 (171.8 ± 53.7 vs 165.5 ± 52.4 mL; p = .16); and no significant difference in LVESV for R1 (mean ± SD, 88.1 ± 49.3 vs 86.0 ± 50.5 mL; p = .45) or R2 (85.2 ± 48.1 vs 81.3 ± 48.2 mL; p = .10). The mean bias between the cine-DL and standard sequences by LV measurement was as follows: LVEF, 0.4% for R1 and 0.7% for R2; LVEDV, 6.3 mL for R1 and 11.3 mL for R2; and LVESV, 2.1 mL for R1 and 3.9 mL for R2. Subjective image quality was better for cine-DL sequence than the standard sequence for R1 (mean ± SD, 2.3 ± 0.5 vs 1.9 ± 0.8; p = .02) and R2 (2.2 ± 0.4 vs 1.9 ± 0.7; p = .02). R1 reported no significant difference between the cine-DL and standard sequences for off-resonance artifacts (3.8% vs 23.1% examinations; p = .10) and parallel imaging artifacts (3.8% vs 19.2%; p = .19); blurring artifacts were more frequent for the cine-DL sequence than the standard sequence (42.3% vs 7.7% examinations; p = .008). CONCLUSION. A free-breathing cine-DL sequence, in comparison with a standard breath-hold cine sequence, showed very small bias for LVEF measurements and better subjective quality. The cine-DL sequence yielded greater LV volumes than the standard sequence. CLINICAL IMPACT. A free-breathing cine-DL sequence may yield reliable LVEF measurements in patients with IHD unable to repeatedly breath-hold. TRIAL REGISTRATION. ClinicalTrials.gov NCT05105984.


Assuntos
Suspensão da Respiração , Aprendizado Profundo , Imagem Cinética por Ressonância Magnética , Isquemia Miocárdica , Humanos , Masculino , Feminino , Estudos Prospectivos , Isquemia Miocárdica/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Idoso , Interpretação de Imagem Assistida por Computador/métodos
11.
Heart Vessels ; 39(2): 135-143, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37777970

RESUMO

Interstitial lung disease and cardiac involvement are common manifestations and prognostic factors of systemic sclerosis. However, it is unclear whether impaired right atrial function associated with interstitial lung disease in systemic sclerosis can be used as a prognostic factor in this patient population. Therefore, this study aimed to investigate the relationship between right atrial function, interstitial lung disease, and prognosis in patients with systemic sclerosis using tissue tracking analysis with cine cardiac magnetic resonance imaging. In this retrospective observational study, a total of 40 patients with systemic sclerosis were enrolled. Tissue tracking analysis was used to obtain time curves of right atrial strain. Reservoir (total strain), conduit (passive strain), and booster (active strain) pump function were calculated, and right atrial strain, interstitial lung disease, and clinical outcomes were examined. An adverse clinical event was defined as all-cause death. Overall, 23 patients had interstitial lung disease (58%). Six patients died during the follow-up (median, 44 months). The total skin score and right ventricular systolic pressure on echocardiography were higher in patients with an event than in those without an event (28 ± 16% vs. 13 ± 13%, P = 0.02; 46.3 ± 10.7 mmHg vs. 36.0 ± 8.5 mmHg, P = 0.01, respectively). Further, right atrial total strain and active strain were significantly lower in patients with an event than in those without an event (14.3 ± 11.3% vs. 25.8 ± 11.4%, P = 0.03; 3.48 ± 2.37 vs. 11.7 ± 6.78, P = 0.007, respectively). Multivariate analysis revealed that active strain was an independent predictor of all-cause death (hazard ratio 0.76, P = 0.029). Kaplan-Meier analysis revealed that the survival rate was significantly higher in patients with right atrial active strain levels above the cutoff 7.4 (P < 0.05). In systemic sclerosis, right atrial booster function was predictive of mortality. Hence, right atrial functional assessment may have incremental prognostic value for patients with systemic sclerosis, leading to better risk stratification.


Assuntos
Doenças Pulmonares Intersticiais , Escleroderma Sistêmico , Humanos , Átrios do Coração/diagnóstico por imagem , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Pulmonares Intersticiais/etiologia , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Prognóstico , Escleroderma Sistêmico/complicações , Escleroderma Sistêmico/diagnóstico , Estudos Retrospectivos
12.
BMC Med Imaging ; 24(1): 124, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38802736

RESUMO

BACKGROUND: The prevalence of hypertensive heart disease (HHD) is high and there is currently no easy way to detect early HHD. Explore the application of radiomics using cardiac magnetic resonance (CMR) non-enhanced cine sequences in diagnosing HHD and latent cardiac changes caused by hypertension. METHODS: 132 patients who underwent CMR scanning were divided into groups: HHD (42), hypertension with normal cardiac structure and function (HWN) group (46), and normal control (NOR) group (44). Myocardial regions of the end-diastolic (ED) and end-systolic (ES) phases of the CMR short-axis cine sequence images were segmented into regions of interest (ROI). Three feature subsets (ED, ES, and ED combined with ES) were established after radiomic least absolute shrinkage and selection operator feature selection. Nine radiomic models were built using random forest (RF), support vector machine (SVM), and naive Bayes. Model performance was analyzed using receiver operating characteristic curves, and metrics like accuracy, area under the curve (AUC), precision, recall, and specificity. RESULTS: The feature subsets included first-order, shape, and texture features. SVM of ED combined with ES achieved the highest accuracy (0.833), with a macro-average AUC of 0.941. AUCs for HHD, HWN, and NOR identification were 0.967, 0.876, and 0.963, respectively. Precisions were 0.972, 0.740, and 0.826; recalls were 0.833, 0.804, and 0.863, respectively; and specificities were 0.989, 0.863, and 0.909, respectively. CONCLUSIONS: Radiomics technology using CMR non-enhanced cine sequences can detect early cardiac changes due to hypertension. It holds promise for future use in screening for latent cardiac damage in early HHD.


Assuntos
Diagnóstico Precoce , Hipertensão , Imagem Cinética por Ressonância Magnética , Humanos , Feminino , Masculino , Imagem Cinética por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Hipertensão/diagnóstico por imagem , Hipertensão/complicações , Máquina de Vetores de Suporte , Cardiopatias/diagnóstico por imagem , Idoso , Adulto , Teorema de Bayes , Curva ROC , Interpretação de Imagem Assistida por Computador/métodos , Radiômica
13.
Sensors (Basel) ; 24(4)2024 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-38400470

RESUMO

Cardiac CINE, a form of dynamic cardiac MRI, is indispensable in the diagnosis and treatment of heart conditions, offering detailed visualization essential for the early detection of cardiac diseases. As the demand for higher-resolution images increases, so does the volume of data requiring processing, presenting significant computational challenges that can impede the efficiency of diagnostic imaging. Our research presents an approach that takes advantage of the computational power of multiple Graphics Processing Units (GPUs) to address these challenges. GPUs are devices capable of performing large volumes of computations in a short period, and have significantly improved the cardiac MRI reconstruction process, allowing images to be produced faster. The innovation of our work resides in utilizing a multi-device system capable of processing the substantial data volumes demanded by high-resolution, five-dimensional cardiac MRI. This system surpasses the memory capacity limitations of single GPUs by partitioning large datasets into smaller, manageable segments for parallel processing, thereby preserving image integrity and accelerating reconstruction times. Utilizing OpenCL technology, our system offers adaptability and cross-platform functionality, ensuring wider applicability. The proposed multi-device approach offers an advancement in medical imaging, accelerating the reconstruction process and facilitating faster and more effective cardiac health assessment.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Coração/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos
14.
Magn Reson Med ; 89(3): 977-989, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36346081

RESUMO

PURPOSE: To develop a free-breathing (FB) 2D radial balanced steady-state free precession cine cardiac MRI method with 100% respiratory gating efficiency using respiratory auto-calibrated motion correction (RAMCO) based on a motion-sensing camera. METHODS: The signal from a respiratory motion-sensing camera was recorded during a FB retrospectively electrocardiogram triggered 2D radial balanced steady-state free precession acquisition using pseudo-tiny-golden-angle ordering. With RAMCO, for each acquisition the respiratory signal was retrospectively auto-calibrated by applying different linear translations, using the resulting in-plane image sharpness as a criterium. The auto-calibration determines the optimal magnitude of the linear translations for each of the in-plane directions to minimize motion blurring caused by bulk respiratory motion. Additionally, motion-weighted density compensation was applied during radial gridding to minimize through-plane and non-bulk motion blurring. Left ventricular functional parameters and sharpness scores of FB radial cine were compared with and without RAMCO, and additionally with conventional breath-hold Cartesian cine on 9 volunteers. RESULTS: FB radial cine with RAMCO had similar sharpness scores as conventional breath-hold Cartesian cine and the left ventricular functional parameters agreed. For FB radial cine, RAMCO reduced respiratory motion artifacts with a statistically significant difference in sharpness scores (P < 0.05) compared to reconstructions without motion correction. CONCLUSION: 2D radial cine imaging with RAMCO allows evaluation of left ventricular functional parameters in FB with 100% respiratory efficiency. It eliminates the need for breath-holds, which is especially valuable for patients with no or impaired breath-holding capacity. Validation of the proposed method on patients is warranted.


Assuntos
Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda , Humanos , Suspensão da Respiração , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Respiração , Estudos Retrospectivos , Função Ventricular Esquerda/fisiologia
15.
Magn Reson Med ; 90(3): 1041-1052, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37183485

RESUMO

PURPOSE: To develop and evaluate a 3D sector-wise golden-angle (3D-SWIG) profile ordering scheme for cardiovascular MR cine imaging that maintains high k-space uniformity after electrocardiogram (ECG) binning. METHOD: Cardiovascular MR (CMR) was performed at 1.5 T. A balanced SSFP pulse sequence was implemented with a novel 3D-SWIG radial ordering, where k-space was divided into wedges, and each wedge was acquired in a separate heartbeat. The high uniformity of k-space coverage after physiological binning can be used to perform functional imaging using a very short acquisition. The 3D-SWIG was compared with two commonly used 3D radial trajectories for CMR (i.e., double golden angle and spiral phyllotaxis) in numerical simulations. Free-breathing 3D-SWIG and conventional breath-held 2D cine were compared in patients (n = 17) referred clinically for CMR. Quantitative comparison was performed based on left ventricular segmentation. RESULTS: Numerical simulations showed that 3D-SWIG both required smaller steps between successive readouts and achieved better k-space sampling uniformity after binning than either the double golden angle or spiral phyllotaxis trajectories. In vivo evaluation showed that measurements of left ventricular ejection fraction calculated from a 48 heart-beat free-breathing 3D-SWIG acquisition were highly reproducible and agreed with breath-held 2D-Cartesian cine (mean ± SD difference of -3.1 ± 3.5% points). CONCLUSIONS: The 3D-SWIG acquisition offers a simple solution for highly improved k-space uniformity after physiological binning. The feasibility of the 3D-SWIG method is demonstrated in this study through whole-heart cine imaging during free breathing with an acquisition time of less than 1 min.


Assuntos
Coração , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Humanos , Eletrocardiografia , Respiração , Coração/diagnóstico por imagem , Frequência Cardíaca , Volume Sistólico , Função Ventricular Esquerda
16.
Magn Reson Med ; 89(6): 2242-2254, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36763898

RESUMO

PURPOSE: To develop a motion-robust reconstruction technique for free-breathing cine imaging with multiple averages. METHOD: Retrospective motion correction through multiple average k-space data elimination (REMAKE) was developed using iterative removal of k-space segments (from individual k-space samples) that contribute most to motion corruption while combining any remaining segments across multiple signal averages. A variant of REMAKE, termed REMAKE+, was developed to address any losses in SNR due to k-space information removal. With REMAKE+, multiple reconstructions using different initial conditions were performed, co-registered, and averaged. Both techniques were validated against clinical "standard" signal averaging reconstruction in a static phantom (with simulated motion) and 15 patients undergoing free-breathing cine imaging with multiple averages. Quantitative analysis of myocardial sharpness, blood/myocardial SNR, myocardial-blood contrast-to-noise ratio (CNR), as well as subjective assessment of image quality and rate of diagnostic quality images were performed. RESULTS: In phantom, motion artifacts using "standard" (RMS error [RMSE]: 2.2 ± 0.5) were substantially reduced using REMAKE/REMAKE+ (RMSE: 1.5 ± 0.4/1.0 ± 0.4, p < 0.01). In patients, REMAKE/REMAKE+ led to higher myocardial sharpness (0.79 ± 0.09/0.79 ± 0.1 vs. 0.74 ± 0.12 for "standard", p = 0.004/0.04), higher image quality (1.8 ± 0.2/1.9 ± 0.2 vs. 1.6 ± 0.4 for "standard", p = 0.02/0.008), and a higher rate of diagnostic quality images (99%/100% vs. 94% for "standard"). Blood/myocardial SNR for "standard" (94 ± 30/33 ± 10) was higher vs. REMAKE (80 ± 25/28 ± 8, p = 0.002/0.005) and tended to be lower vs. REMAKE+ (105 ± 33/36 ± 12, p = 0.02/0.06). Myocardial-blood CNR for "standard" (61 ± 22) was higher vs. REMAKE (53 ± 19, p = 0.003) and lower vs. REMAKE+ (69 ± 24, p = 0.007). CONCLUSIONS: Compared to "standard" signal averaging reconstruction, REMAKE and REMAKE+ provide improved myocardial sharpness, image quality, and rate of diagnostic quality images.


Assuntos
Coração , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Estudos Retrospectivos , Coração/diagnóstico por imagem , Respiração , Movimento (Física) , Artefatos
17.
Magn Reson Med ; 90(1): 222-230, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36864561

RESUMO

PURPOSE: To investigate the feasibility of combining simultaneous multislice (SMS) and region-optimized virtual coils (ROVir) for single breath-hold CINE imaging. METHOD: ROVir is a recent virtual coil approach that allows reduced-field of view (FOV) imaging by localizing the signal from a region-of-interest (ROI) and/or suppressing the signal from unwanted spatial regions. In this work, ROVir is used for reduced-FOV SMS bSSFP CINE imaging, which enables whole heart CINE with a single breath-hold acquisition. RESULTS: Reduced-FOV CINE with either SMS-only or ROVir-only resulted in significant aliasing, with severely reduced image quality when compared to the full FOV reference CINE, while the visual appearance of aliasing was substantially reduced with the proposed SMS+ROVir. The end diastolic volume, end systolic volume, and ejection fraction obtained using the proposed approach were similar to the clinical reference (correlations of 0.92, 0.94, and 0.88, respectively with p < 0 . 05 $$ p<0.05 $$ in each case, and biases of 0.1, 1.6 mL, and - 0 . 6 % $$ -0.6\% $$ , respectively). No statistically significant differences for these parameters were found with a Wilcoxon rank test (p = 0.96, 0.20, and 0.40, respectively). CONCLUSION: We demonstrated that reduced-FOV CINE imaging with SMS+ROVir enables single breath-hold whole-heart imaging without compromising visual image quality or quantitative cardiac function parameters.


Assuntos
Suspensão da Respiração , Imagem Cinética por Ressonância Magnética , Imagem Cinética por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/métodos
18.
Magn Reson Med ; 89(1): 217-232, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36198014

RESUMO

PURPOSE: To introduce non-rigid cardiac motion correction into a novel free-running framework for the simultaneous acquisition of 3D whole-heart myocardial T 1 $$ {T}_1 $$ and T 2 $$ {T}_2 $$ maps and cine images, enabling a ∼ $$ \sim $$ 3-min scan. METHODS: Data were acquired using a free-running 3D golden-angle radial readout interleaved with inversion recovery and T 2 $$ {T}_2 $$ -preparation pulses. After correction for translational respiratory motion, non-rigid cardiac-motion-corrected reconstruction with dictionary-based low-rank compression and patch-based regularization enabled 3D whole-heart T 1 $$ {T}_1 $$ and T 2 $$ {T}_2 $$ mapping at any given cardiac phase as well as whole-heart cardiac cine imaging. The framework was validated and compared with established methods in 11 healthy subjects. RESULTS: Good quality 3D T 1 $$ {T}_1 $$ and T 2 $$ {T}_2 $$ maps and cine images were reconstructed for all subjects. Septal T 1 $$ {T}_1 $$ values using the proposed approach ( 1200 ± 50 $$ 1200\pm 50 $$ ms) were higher than those from a 2D MOLLI sequence ( 1063 ± 33 $$ 1063\pm 33 $$ ms), which is known to underestimate T 1 $$ {T}_1 $$ , while T 2 $$ {T}_2 $$ values from the proposed approach ( 51 ± 4 $$ 51\pm 4 $$ ms) were in good agreement with those from a 2D GraSE sequence ( 51 ± 2 $$ 51\pm 2 $$ ms). CONCLUSION: The proposed technique provides 3D T 1 $$ {T}_1 $$ and T 2 $$ {T}_2 $$ maps and cine images with isotropic spatial resolution in a single ∼ $$ \sim $$ 3.3-min scan.


Assuntos
Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Coração/diagnóstico por imagem , Miocárdio , Movimento (Física) , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética , Imagens de Fantasmas
19.
NMR Biomed ; : e4942, 2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-36999225

RESUMO

The aim of the current study was to develop a novel approach for 2D breath-hold cardiac cine imaging from a single heartbeat, by combining cardiac motion-corrected reconstructions and nonrigidly aligned patch-based regularization. Conventional cardiac cine imaging is obtained via motion-resolved reconstructions of data acquired over multiple heartbeats. Here, we achieve single-heartbeat cine imaging by incorporating nonrigid cardiac motion correction into the reconstruction of each cardiac phase, in conjunction with a motion-aligned patch-based regularization. The proposed Motion-Corrected CINE (MC-CINE) incorporates all acquired data into the reconstruction of each (motion-corrected) cardiac phase, resulting in a better posed problem than motion-resolved approaches. MC-CINE was compared with iterative sensitivity encoding (itSENSE) and Extra-Dimensional Golden Angle Radial Sparse Parallel (XD-GRASP) in 14 healthy subjects in terms of image sharpness, reader scoring (range: 1-5) and reader ranking (range: 1-9) of image quality, and single-slice left ventricular assessment. MC-CINE was significantly superior to both itSENSE and XD-GRASP using 20 heartbeats, two heartbeats, and one heartbeat. Iterative SENSE, XD-GRASP, and MC-CINE achieved a sharpness of 74%, 74%, and 82% using 20 heartbeats, and 53%, 66%, and 82% with one heartbeat, respectively. The corresponding results for reader scoring were 4.0, 4.7, and 4.9 with 20 heartbeats, and 1.1, 3.0, and 3.9 with one heartbeat. The corresponding results for reader ranking were 5.3, 7.3, and 8.6 with 20 heartbeats, and 1.0, 3.2, and 5.4 with one heartbeat. MC-CINE using a single heartbeat presented nonsignificant differences in image quality to itSENSE with 20 heartbeats. MC-CINE and XD-GRASP at one heartbeat both presented a nonsignificant negative bias of less than 2% in ejection fraction relative to the reference itSENSE. It was concluded that the proposed MC-CINE significantly improves image quality relative to itSENSE and XD-GRASP, enabling 2D cine from a single heartbeat.

20.
J Magn Reson Imaging ; 58(3): 807-814, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36533630

RESUMO

BACKGROUND: Although radiomics features of the left ventricular wall have been used to assess cardiac diseases, radiomics features of the cardiac blood pool have been relatively ignored. PURPOSE: To test the hypothesis that cine MRI-derived radiomics features of the cardiac blood pool are associated with cardiac function and motion. STUDY TYPE: Retrospective. POPULATION: A total of 26 healthy volunteers (51.2 ± 15.6 years; 17 males). FIELD STRENGTH/SEQUENCE: A 1.5 T/balanced steady-state free precession (bSSFP). ASSESSMENT: The radiomics features (107 features in seven classes) of the blood pool of the left/right ventricle/atrium (LV/RV/LA/RA) were extracted on four-chamber cine images (25 phases). Conventional cardiac function parameters (volumes, ejection fraction [EF] and longitudinal strain) were assessed in each cardiac chamber. Intraobserver- and interobserver agreements of radiomics features of all chambers acquired at all phases were assessed, as well as scan-rescan agreement in a subset of 13 volunteers. STATISTICAL TESTS: Pearson correlation coefficients (r) were used to assess the associations between peak values of radiomics features and end-diastolic (or maximal) volume, end-systolic (or minimal) volume, EF, and longitudinal strain of corresponding chambers. Good intraobserver, interobserver, and scan-rescan agreements for radiomics features acquired were defined as intraclass correlation coefficient (ICC) > 0.7 or coefficient of variation (CoV) < 20%. RESULTS: Most radiomics features of the blood pool varied periodically throughout the cardiac cycle. Peak values of chamber-specific blood pool radiomics features were correlated with traditional cardiac function and motion indices of corresponding chambers (r: 0.4-0.87). Ninety-three (87%), 86 (80%), and 73 (68%) radiomics features demonstrated good intraobserver, interobserver, and scan-rescan reproducibility, respectively. CONCLUSION: Cine MRI-derived radiomics features within LV/RV/LA/RA are associated with traditional cardiac function and motion indices of corresponding chambers and may have the potential to become novel quantitative imaging biomarkers in cardiovascular medicine. EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: 1.


Assuntos
Ventrículos do Coração , Imagem Cinética por Ressonância Magnética , Masculino , Humanos , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Ventrículos do Coração/diagnóstico por imagem , Átrios do Coração , Volume Sistólico , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS