Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Adv Exp Med Biol ; 3234: 191-205, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38507208

RESUMO

Recent advancements in cryo-electron microscopy (cryo-TEM) have enabled the determination of structures of macromolecular complexes at near-atomic resolution, establishing it as a pivotal tool in Structural Biology. This high resolution allows for the detection of ligands and substrates under physiological conditions. Enhancements in detectors and imaging devices, like phase plates, improve signal quality, facilitating the reconstruction of even smaller macromolecular complexes. The 100-kDa barrier has been surpassed, presenting new opportunities for pharmacological research and expanding the scope of crystallographic analyses in the pharmaceutical industry. Cryo-TEM produces vast data sets from minimal samples, and refined classification methods can identify different conformational states of macromolecular complexes, offering deeper insights into the functional characteristics of macromolecular systems. Additionally, cryo-TEM is paving the way for time-resolved microscopy, with rapid freezing techniques capturing snapshots of vital structural changes in biological complexes. Finally, in Structural Cell Biology, advanced cryo-TEM, through tomographic procedures, is revealing conformational changes related to the specific subcellular localization of macromolecular systems and their interactions within cells.


Assuntos
Biologia Molecular , Microscopia Crioeletrônica/métodos , Conformação Molecular , Substâncias Macromoleculares/química
2.
J Struct Biol ; 214(2): 107852, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35351542

RESUMO

The potential of energy filtering and direct electron detection for cryo-electron microscopy (cryo-EM) has been well documented. Here, we assess the performance of recently introduced hardware for cryo-electron tomography (cryo-ET) and subtomogram averaging (STA), an increasingly popular structural determination method for complex 3D specimens. We acquired cryo-ET datasets of EIAV virus-like particles (VLPs) on two contemporary cryo-EM systems equipped with different energy filters and direct electron detectors (DED), specifically a Krios G4, equipped with a cold field emission gun (CFEG), Thermo Fisher Scientific Selectris X energy filter, and a Falcon 4 DED; and a Krios G3i, with a Schottky field emission gun (XFEG), a Gatan Bioquantum energy filter, and a K3 DED. We performed constrained cross-correlation-based STA on equally sized datasets acquired on the respective systems. The resulting EIAV CA hexamer reconstructions show that both systems perform comparably in the 4-6 Å resolution range based on Fourier-Shell correlation (FSC). In addition, by employing a recently introduced multiparticle refinement approach, we obtained a reconstruction of the EIAV CA hexamer at 2.9 Å. Our results demonstrate the potential of the new generation of energy filters and DEDs for STA, and the effects of using different processing pipelines on their STA outcomes.


Assuntos
Elétrons , Processamento de Imagem Assistida por Computador , Microscopia Crioeletrônica/métodos , Tomografia com Microscopia Eletrônica/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X
3.
Microsc Microanal ; 26(6): 1110-1116, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32867871

RESUMO

A scanning precession electron diffraction system has been integrated with a direct electron detector to allow the collection of improved quality diffraction patterns. This has been used on a two-phase α­ß titanium alloy (Timetal® 575) for phase and orientation mapping using an existing pattern-matching algorithm and has been compared to the commonly used detector system, which consisted of a high-speed video-camera imaging the small phosphor focusing screen. Noise is appreciably lower with the direct electron detector, and this is especially noticeable further from the diffraction pattern center where the real electron scattering is reduced and both diffraction spots and inelastic scattering between spots are weaker. The results for orientation mapping are a significant improvement in phase and orientation indexing reliability, especially of fine nanoscale laths of α-Ti, where the weak diffracted signal is rather lost in the noise for the optically coupled camera. This was done at a dose of ~19 e−/Å2, and there is clearly a prospect for reducing the current further while still producing indexable patterns. This opens the way for precession diffraction phase and orientation mapping of radiation-sensitive crystalline materials.

4.
Microsc Microanal ; 24(4): 406-419, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30175702

RESUMO

Cryo-electron microscopy (cryo-EM) is a powerful tool for macromolecular to near-atomic resolution structure determination in the biological sciences. The specimen is maintained in a near-native environment within a thin film of vitreous ice and imaged in a transmission electron microscope. The images can then be processed by a number of computational methods to produce three-dimensional information. Recent advances in sample preparation, imaging, and data processing have led to tremendous growth in the field of cryo-EM by providing higher resolution structures and the ability to investigate macromolecules within the context of the cell. Here, we review developments in sample preparation methods and substrates, detectors, phase plates, and cryo-correlative light and electron microscopy that have contributed to this expansion. We also have included specific biological applications.


Assuntos
Microscopia Crioeletrônica/métodos , Tomografia com Microscopia Eletrônica/métodos , Imageamento Tridimensional/métodos , Substâncias Macromoleculares/análise , Manejo de Espécimes/métodos
5.
J Struct Biol ; 189(2): 87-97, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25528571

RESUMO

With the introduction of direct electron detectors (DED) to the field of electron cryo-microscopy, a wave of atomic-resolution structures has become available. As the new detectors still require comparative characterization, we have used tobacco mosaic virus (TMV) as a test specimen to study the quality of 3D image reconstructions from data recorded on the two direct electron detector cameras, K2 Summit and Falcon II. Using DED movie frames, we explored related image-processing aspects and compared the performance of micrograph-based and segment-based motion correction approaches. In addition, we investigated the effect of dose deposition on the atomic-resolution structure of TMV and show that radiation damage affects negative carboxyl chains first in a side-chain specific manner. Finally, using 450,000 asymmetric units and limiting the effects of radiation damage, we determined a high-resolution cryo-EM map at 3.35Å resolution. Here, we provide a comparative case study of highly ordered TMV recorded on different direct electron detectors to establish recording and processing conditions that enable structure determination up to 3.2Å in resolution using cryo-EM.


Assuntos
Proteínas do Capsídeo/ultraestrutura , Vírus do Mosaico do Tabaco/ultraestrutura , Microscopia Crioeletrônica/instrumentação , Modelos Moleculares , Estrutura Quaternária de Proteína
6.
Arch Biochem Biophys ; 581: 54-8, 2015 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-25912526

RESUMO

The field of three-dimensional electron microscopy began more than 45years ago with a reconstruction of a helical phage tail, and helical polymers continue to be important objects for three-dimensional reconstruction due to the centrality of helical protein and nucleoprotein polymers in all aspects of biology. We are now witnessing a fundamental revolution in this area, made possible by direct electron detectors, which has led to near-atomic resolution for a number of important helical structures. Most importantly, the possibility of achieving such resolution routinely for a vast number of helical samples is within our reach. One of the main problems in helical reconstruction, ambiguities in assigning the helical symmetry, is overcome when one reaches a resolution where secondary structure is clearly visible. However, obstacles still exist due to the intrinsic variability within many helical filaments.


Assuntos
Microscopia Eletrônica/métodos , Polímeros/química , Bacteriófagos/ultraestrutura , Estrutura Molecular
7.
IUCrJ ; 7(Pt 5): 780-781, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32939268

RESUMO

Electron-event representation saves the spatial and temporal coordinates of every electron with ultimate accuracy. Through maximum signal extraction, it will improve the performance of electron cryo-microscopy.

8.
IUCrJ ; 6(Pt 5): 921-926, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31576224

RESUMO

Microcrystal electron diffraction (MicroED) combines crystallography and electron cryo-microscopy (cryo-EM) into a method that is applicable to high-resolution structure determination. In MicroED, nanosized crystals, which are often intractable using other techniques, are probed by high-energy electrons in a transmission electron microscope. Diffraction data are recorded by a camera in movie mode: the nanocrystal is continuously rotated in the beam, thus creating a sequence of frames that constitute a movie with respect to the rotation angle. Until now, diffraction-optimized cameras have mostly been used for MicroED. Here, the use of a direct electron detector that was designed for imaging is reported. It is demonstrated that data can be collected more rapidly using the Falcon III for MicroED and with markedly lower exposure than has previously been reported. The Falcon III was operated at 40 frames per second and complete data sets reaching atomic resolution were recorded in minutes. The resulting density maps to 2.1 Šresolution of the serine protease proteinase K showed no visible signs of radiation damage. It is thus demonstrated that dedicated diffraction-optimized detectors are not required for MicroED, as shown by the fact that the very same cameras that are used for imaging applications in electron microscopy, such as single-particle cryo-EM, can also be used effectively for diffraction measurements.

9.
Acta Crystallogr B Struct Sci Cryst Eng Mater ; 75(Pt 4): 495-504, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32830707

RESUMO

3D electron diffraction is an emerging technique for the structural analysis of nanocrystals. The challenges that 3D electron diffraction has to face for providing reliable data for structure solution and the different ways of overcoming these challenges are described. The route from zone axis patterns towards 3D electron diffraction techniques such as precession-assisted electron diffraction tomography, rotation electron diffraction and continuous rotation is also discussed. Finally, the advantages of the new hybrid detectors with high sensitivity and fast readout are demonstrated with a proof of concept experiment of continuous rotation electron diffraction on a natrolite nanocrystal.

10.
IUCrJ ; 6(Pt 6): 1007-1013, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31709056

RESUMO

Direct electron detectors (DEDs) have revolutionized cryo-electron microscopy (cryo-EM) by facilitating the correction of beam-induced motion and radiation damage, and also by providing high-resolution image capture. A new-generation DED, the DE64, has been developed by Direct Electron that has good performance in both integrating and counting modes. The camera has been characterized in both modes in terms of image quality, throughput and resolution of cryo-EM reconstructions. The modulation transfer function, noise power spectrum and detective quantum efficiency (DQE) were determined for both modes, as well as the number of images per unit time. Although the DQE for counting mode was superior to that for integrating mode, the data-collection throughput for this mode was more than ten times slower. Since throughput and resolution are related in single-particle cryo-EM, data for apoferritin were collected and reconstructed using integrating mode, integrating mode in conjunction with a Volta phase plate (VPP) and counting mode. Only the counting-mode data resulted in a better than 3 Šresolution reconstruction with similar numbers of particles, and this increased performance could not be compensated for by the increased throughput of integrating mode or by the increased low-frequency contrast of integrating mode with the VPP. These data show that the superior image quality provided by counting mode is more important for high-resolution cryo-EM reconstructions than the superior throughput of integrating mode.

11.
Methods Enzymol ; 579: 307-28, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27572732

RESUMO

Treating helices as single-particle-like segments followed by helical image reconstruction has become the method of choice for high-resolution structure determination of well-ordered helical viruses as well as flexible filaments. In this review, we will illustrate how the combination of latest hardware developments with optimized image processing routines have led to a series of near-atomic resolution structures of helical assemblies. Originally, the treatment of helices as a sequence of segments followed by Fourier-Bessel reconstruction revealed the potential to determine near-atomic resolution structures from helical specimens. In the meantime, real-space image processing of helices in a stack of single particles was developed and enabled the structure determination of specimens that resisted classical Fourier helical reconstruction and also facilitated high-resolution structure determination. Despite the progress in real-space analysis, the combination of Fourier and real-space processing is still commonly used to better estimate the symmetry parameters as the imposition of the correct helical symmetry is essential for high-resolution structure determination. Recent hardware advancement by the introduction of direct electron detectors has significantly enhanced the image quality and together with improved image processing procedures has made segmented helical reconstruction a very productive cryo-EM structure determination method.


Assuntos
Algoritmos , Microscopia Crioeletrônica/métodos , Elétrons , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Software , Actinas/ultraestrutura , Microscopia Crioeletrônica/instrumentação , Proteínas de Escherichia coli/ultraestrutura , Análise de Fourier , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Modelos Moleculares , Conformação Proteica em alfa-Hélice , Vírus do Mosaico do Tabaco/ultraestrutura , Tropomiosina/ultraestrutura
12.
Ultramicroscopy ; 170: 86-95, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27566048

RESUMO

This review article discusses the current and future possibilities for the application of in situ transmission electron microscopy to reveal synthesis pathways and functional mechanisms in complex and nanoscale materials. The findings of a group of scientists, representing academia, government labs and private sector entities (predominantly commercial vendors) during a workshop, held at the Center for Nanoscale Science and Technology- National Institute of Science and Technology (CNST-NIST), are discussed. We provide a comprehensive review of the scientific needs and future instrument and technique developments required to meet them.

13.
Microscopy (Oxf) ; 63(2): 119-30, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24401331

RESUMO

There is great interest in developing novel position-sensitive direct detectors for transmission electron microscopy (TEM) that do not rely in the conversion of electrons into photons. Direct imaging improves contrast and efficiency and allows the operation of the microscope at lower energies and at lower doses without loss in resolution, which is especially important for studying soft materials and biological samples. We investigate the feasibility of employing a silicon strip detector as an imaging detector for TEM. This device, routinely used in high-energy particle physics, can detect small variations in electric current associated with the impact of a single charged particle. The main advantages of using this type of sensor for direct imaging in TEM are its intrinsic radiation hardness and large detection area. Here, we detail design, simulation, fabrication and tests in a TEM of the front-end electronics developed using low-cost discrete components and discuss the limitations and applications of this technology for TEM.

14.
Elife ; 2: e00573, 2013 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-23426864

RESUMO

Improved electron detectors and image-processing techniques will allow the structures of macromolecules to be determined from tens of thousands of single-particle cryo-EM images, rather than the hundreds of thousands needed previously.


Assuntos
Microscopia Crioeletrônica/métodos , Processamento de Imagem Assistida por Computador
15.
Elife ; 2: e00461, 2013 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-23427024

RESUMO

Although electron cryo-microscopy (cryo-EM) single-particle analysis has become an important tool for structural biology of large and flexible macro-molecular assemblies, the technique has not yet reached its full potential. Besides fundamental limits imposed by radiation damage, poor detectors and beam-induced sample movement have been shown to degrade attainable resolutions. A new generation of direct electron detectors may ameliorate both effects. Apart from exhibiting improved signal-to-noise performance, these cameras are also fast enough to follow particle movements during electron irradiation. Here, we assess the potentials of this technology for cryo-EM structure determination. Using a newly developed statistical movie processing approach to compensate for beam-induced movement, we show that ribosome reconstructions with unprecedented resolutions may be calculated from almost two orders of magnitude fewer particles than used previously. Therefore, this methodology may expand the scope of high-resolution cryo-EM to a broad range of biological specimens.DOI:http://dx.doi.org/10.7554/eLife.00461.001.


Assuntos
Microscopia Crioeletrônica/métodos , Ribossomos/ultraestrutura , Thermus thermophilus/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA