Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Sensors (Basel) ; 22(7)2022 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-35408280

RESUMO

The torsional fatigue test determines the fatigue limit for a certain asymmetry coefficient of the cycle. The assessment of fatigue tests is performed on specialized machines. There are two types of torsion testing machines: universal machines that have the torsion component and specialized machines only for torsion testing. Nevertheless, no matter which proposed option we choose, the purchase prices for these testing machines or the values spent for self-management are quite high. This paper presented a device used for torsion fatigue testing, adaptable to a universal pulsating testing machine, designed to determine the torsion fatigue limit for different materials. The built device is simple and reliable, and therefore inexpensive. By using this device, we can determine the limit of the torsional fatigue after any stress cycle and we can use the parameters obtained from the universal machine to which it was attached. The torque and twisting angle of the test specimen during the test can be determined by calculation. The paper also presented an experimental method for determining shear strains based on calibration experiment, using a specimen on which strain gauges were mounted. The values taken from this calibration experiment were compared with those obtained from the theoretical calculation.


Assuntos
Titânio , Desenho de Equipamento , Teste de Materiais , Estresse Mecânico , Torque , Torção Mecânica
2.
Fatigue Fract Eng Mater Struct ; 45(11): 3361-3377, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36590824

RESUMO

The influence of load ratio on the high and very high cycle fatigue (VHCF) strength of Ck45M steel processed by thermomechanical rolling integrated direct quenching was investigated. Ultrasonic fatigue tests were performed under uniaxial and torsional loading at load ratios of R = -1, 0.05, 0.3, and 0.5 with smooth specimens and specimens containing artificially introduced defects. Up to 2 × 105 cycles, failure originated from surface aluminate inclusions and pits under both loading conditions. The prevailing fracture mechanisms in the VHCF regime were interior crack initiation under uniaxial loading and surface shear crack initiation under torsional loading. The mean-stress sensitivity and the fatigue strength were evaluated using fracture mechanics approaches. Equal fatigue limits for uniaxial and torsional loading were determined considering the size of crack initiating defects and the appropriate threshold condition for Mode-I crack growth. Furthermore, the mean-stress sensitivity is independent of loading condition and can be expressed by σ w R = σ w R = - 1 · 1 - R 2 0.63 and τ w R = τ w R = - 1 · 1 - R 2 0.63 .

3.
Int Orthop ; 41(9): 1709-1714, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28349182

RESUMO

PURPOSE: Six different mono-axial and poly-axial distal humeral plating systems with an anatomical plate design were compared. The aim of the biomechanical tests was to examine differences regarding system stiffness, median fatigue limit, and failure mechanisms. METHODS: Different configurations of two double plate fixation systems by two manufacturers for the treatment of complex distal humeral fractures (AO/OTA type C2.3) were biomechanically tested in a physiologically relevant setup. RESULTS: The 180° Stryker configuration presented itself as the system with the highest stiffness, being significantly stiffer (p < 0.001) than every system other than the poly-axial 180° aap system (p = 0.378). For the median fatigue limit the 180° Stryker and poly-axial aap systems were ranked first and second. The failure mechanism for all 90° systems was a fatigue breakage of the posterolateral plate. The 180° aap systems demonstrated breakage of the most distal screws of the lateral plate. The 180° Stryker system demonstrated screw breakage on both the medial and lateral plates. DISCUSSION: Breakage of the posterolateral plate as a failure mechanism for the 90° systems was expected. The 180° systems demonstrated a higher stiffness compared to the 90° constructs for the axial loading. In conclusion, both poly-axial anatomical plating systems provide sufficient stability in this scenario, and the 180° configurations demonstrated superior stiffness.


Assuntos
Placas Ósseas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Fraturas do Úmero/cirurgia , Úmero/cirurgia , Fenômenos Biomecânicos , Parafusos Ósseos , Articulação do Cotovelo , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Humanos , Desenho de Prótese/efeitos adversos , Falha de Prótese/etiologia
4.
Materials (Basel) ; 17(18)2024 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-39336373

RESUMO

The issues of the high-cycle fatigue resistance of notches and the role of non-propagating short cracks in defining the fatigue notch sensitivity and fatigue limit of the configuration are addressed. A fracture mechanics approach is employed to determine the threshold configuration that defines the associated fatigue limit. The influence of notch sharpness, notch size, intrinsic fatigue limit, microstructural dimensions, and the threshold for crack propagation is examined. A simple expression is proposed to estimate the maximum fatigue notch factor, kfMax, which incorporates the influence of these non-propagating cracks. The fatigue limits for both blunt and sharp elliptical notches are analyzed and predicted based on experimental results reported in the literature. Additionally, shallow notches or small defects are analyzed, where it is found that the same hypothesis may not be applicable.

5.
Ultrasonics ; 138: 107236, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38183759

RESUMO

Fatigue properties of polyetheretherketone (PEEK) and multiwall carbon nanotube (CNT) reinforced PEEK were investigated with the ultrasonic fatigue testing method. Lifetimes were measured in the high and very high cycle fatigue regime at resonance frequency 19 kHz and load ratio R = -1. Pulse-pause loading served to avoid specimen self-heating and led to effective cycling frequencies in the range from several hundred Hz to about two kHz. Stress amplitude for 50 % fracture probability at 109 cycles is 21.2 ± 4.3 MPa for unreinforced PEEK (22 % of its tensile strength) and 33.5 ± 3.5 MPa for CNT reinforced PEEK (33 % of its tensile strength). Servohydraulic fatigue tests at 22 Hz with CNT reinforced PEEK delivered fatigue lifetimes comparable to ultrasonic tests, i.e. no frequency effect and no influence of load versus displacement control was observed. Keeping specimen temperature far below the glass transition temperature, ultrasonic fatigue testing of a high temperature resistant plastic was successfully implemented.

6.
Materials (Basel) ; 17(7)2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38612004

RESUMO

Within the scope of this research, patterns of changes in the fatigue life and limit of metals under cyclic stress were identified and the most informative parameters were determined as the basis for developing a method for the universal transformation of experimental data on the fatigue of metals and alloys for their subsequent generalization. Experimental data on metal fatigue, obtained by a large number of authors for a wide range of grades of steels and alloys, under the influence of various combinations of factors, were systematized. A generalized dependence of the recalculated parameters of fatigue life and limit was obtained, its characteristics were assessed, and a sensitivity analysis was performed, confirming the universal nature of the obtained dependence. A system of parameters has been proposed making it possible to consider and forecast high-cycle fatigue processes for a wide range of metals and alloys, under the conditions of various combinations of operating factors, from unified positions and a more general point of view.

7.
Materials (Basel) ; 17(18)2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39336226

RESUMO

Understanding short fatigue-crack propagation behavior is inevitable in the defect-tolerant design of structures. Short cracks propagate differently from long cracks, and the amount of crack closure plays a key role in the propagation behavior of short cracks. In the present paper, the buildup of fatigue-crack closure due to plasticity with crack extension from crack-like defects is simulated with a modified strip yield model, which leaves plastic stretch in the wake of the advancing crack. Crack-like defects are assumed to be closure-free and do not close even under compression. The effect of the size of crack-like defects on the growth and arrest of short cracks was systematically investigated and the cyclic R-curve derived. The cyclic R-curve determined under constant amplitude loading of multiple specimens is confirmed to be independent of the initial defect length. Load-shedding and ΔK-constant loading tests are employed to extend the cyclic R-curve beyond the fatigue limit determined under constant amplitude loading. The initiation stage of cracks is taken into account in R-curves when applied to smooth specimens.

8.
J Clin Med ; 13(6)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38541858

RESUMO

Background: Scientific literature lacks strong support for using narrow diameter implants (NDI) in high masticatory force areas, especially in molars. Implant splinting in cases of multiple missing teeth reduces lateral forces, improves force distribution, and minimizes stress on implants. However, no studies have evaluated the fatigue load resistance of unitary or splinted implants. Methods: This in vitro study compares five groups of new metal alloy implants, including unitary and splinted implants with varying diameters. Mechanical characterization was assessed using a BIONIX 370 testing machine (MTS, Minneapolis, MN, USA) according to ISO 14801. For each of the five study sample groups, (n = 5) specimens underwent monotonic uniaxial compression at break testing and (n = 15) cyclic loading to determine the maximum force (Fmax) and the fatigue life (LF) values. Scanning electron microscopy (SEM) was employed for the fractographic analysis of the fractured samples. Results: The Fmax values for unitary samples ranged from 196 N to 246 N, whereas the two-splinted samples displayed significantly higher values, ranging from 2439 N to 3796 N. Similarly, the LF values for unitary samples ranged from 118 N to 230 N, while the two-splinted samples exhibited notably higher values, ranging from 488 N to 759 N. Conclusions: The observed resistance difference between sample groups in terms of Fmax and LF may be due to variations in effective cross-sectional area, determined by implant diameter and number. Additionally, this disparity may indicate a potential stiffening effect resulting from the splinting process. These findings have significant implications for dental clinical practice, suggesting the potential use of splinted sets of small-sized NDI as replacements for posterior dentition (premolars and molars) in cases of alveolar bone ridge deficiencies.

9.
Materials (Basel) ; 16(13)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37445065

RESUMO

Welding is prone to several defects. To test the fatigue properties of the welded defective joints of high-speed rail bogies, SMA490BW steel cruciform welded joints were employed with artificial defects treatment. Consequently, fatigue tests were conducted on the specimens. Fatigue fracture morphology was studied via scanning electron microscopy. The ABAQUS (version 2022) finite element software was used to calculate the stress distribution and concentration factor of cruciform welded joints with defects. The results show that the fatigue limits of 1 and 2.4 mm defect specimens were approximately 57.2 and 53.75 Mpa, respectively. Furthermore, the stress concentration factor of no, 1 mm, and 2.4 mm defects were 2.246, 4.441, and 6.684, respectively, indicating that the stress concentration factor of 1 and 2.4 mm defects increased by 98 and 198%, respectively, with respect to the no-defect case.

10.
Materials (Basel) ; 16(17)2023 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-37687567

RESUMO

In the field of long-life fatigue, predicting fatigue lives and limits for mechanical components is crucial for ensuring reliability and safety. Fracture mechanics tools have enabled the estimation of fatigue lives for components with small cracks or defects. However, when dealing with defects larger than the microstructural characteristic size, estimating the fatigue resistance of a material requires determining the cyclic resistance curve for the defect-free matrix, which depends on knowledge of the material's intrinsic fatigue limit. This study focuses on the experimental evidence regarding the intrinsic fatigue limit and its correlation with naturally nucleated non-propagating cracks. Fracture mechanics models for small crack propagation are introduced, and their disparities and limitations are analyzed. The concept of intrinsic fatigue limit is then introduced and applied to reanalyze a recent publication. Methods for estimating the intrinsic fatigue limit are explored and applied to experimental results reported in the literature. The need to clarify and accurately predict the intrinsic fatigue limit is highlighted in alloys where the processing generates defects larger than the microstructural size of the matrix, as often observed in materials and components produced using additive manufacturing.

11.
Materials (Basel) ; 16(22)2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-38005114

RESUMO

The high-cycle bending fatigue experiment is one of the most important necessary steps in guiding the crankshaft manufacturing process, especially for high-power engines. In this paper, an accelerated method was proposed to shorten the time period of this experiment. First, the loading period was quickened through the prediction of the residual fatigue life based on the unscented Kalman filtering algorithm approach and the crack growth speed. Then, the accuracy of the predictions was improved obviously based on the modified training section based on the theory of fracture mechanics. Finally, the fatigue limit load analysis result was proposed based on the predicted fatigue life and the modified SAFL (statistical analysis for the fatigue limit) method. The main conclusion proposed from this paper is that compared with the conventional training sections, the modified training sections based on the theory of fracture mechanics can obviously improve the accuracy of the remaining fatigue life prediction results, which makes this approach more suitable for the application. In addition, compared with the system's inherent natural frequency, the fatigue crack can save the experiment time more effectively and thus is superior to the former factor as the failure criterion parameter.

12.
Materials (Basel) ; 16(2)2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36676621

RESUMO

The paper presents and analyzes the results of experimental tests performed on two non-alloy low carbon steels (1.1141 and 1.0122) in cases of their exposure to impact fracture energy and uniaxial high cyclic mechanical stress-controlled fatigue. The experimental results provide insight into the changes in the Charpy impact fracture energy of the V-notched test specimen that occur as a result of temperature changes. The experimental results also provide insight into the mechanical response of the tested materials to mechanical uniaxial high-cycle fatigue at room temperature in an air atmosphere and at different applied stress ratios. Material fatigue tests refer to symmetric (R = -1), asymmetric (R = -0.5) and pulsating tensile (R = 0) cycles. The test results are shown in the S-N diagrams and refer to the highest applied stresses in relation to the number of failures at a given stress ratio. Using the modified staircase method, the fatigue limit (endurance limit) was calculated for both tested materials at each prescribed stress ratio. For both tested steel alloys, and at prescribed stress ratios, the fatigue limit levels (σ_f) are shown as follows: for steel C15E+C (1.1141)→σf[250.8R=-1;&nbsp;345.4R=-0.5;&nbsp;527R=0](MPa); and for steel S235JRC+C (1.0122)→σf[202R=-1;&nbsp;310R=-0.5;&nbsp;462R=0](MPa). All uniaxial fatigue tests were performed on unnotched, smooth, highly-polished specimens. The microhardness of both materials was also tested.

13.
Materials (Basel) ; 15(10)2022 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-35629632

RESUMO

Cold spray technique has been major improved in the last decades, for studying new properties for metals and alloys of aluminum, copper, nickel, and titanium, as well as steels, stainless steel and other types of alloys. Cold sprayed Ni/CrC coatings have the potential to provide a barrier as well as improved protection to steels. Fatigue characteristics of 52100 steel coated with Ni/Chrome-Carbide (Ni/CrC) powder mixture by using cold gas dynamic spray are investigated. Fatigue samples were subjected to symmetrically alternating, axially applied cyclic fatigue loading until failure. The test was stopped if a sample survived more than 5 × 106 cycles at the applied stress. Fracture surfaces for each sample were examined to investigate the behaviour of the coating both at high stress levels and at a high number of stress cycles. Scanning electron microscopy was used to assess the damage in the interface of the two materials. Good fatigue behaviour of the coating material was observed, especially at low stresses and a high number of cycles. Details of the crack initiation region, the stable crack propagation region and the sudden crack expansion region are identified for each sample. In most of the samples, the initiation of the crack occurred on the surface of the base material and propagated into the coating material. The possible effects of coatings on the initial deterioration of the base material and the reduction of the lifespan of the coated system were also investigated. The aim of the paper was to study the interface between the base material and the coating material at the fatigue analysis for different stresses, highlighting the appearance of cracks and the number of breaking cycles required for each sample.

14.
J Mech Behav Biomed Mater ; 136: 105535, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36302274

RESUMO

BACKGROUND: Dental zirconium oxide restorations are milled from pre-sintered blocks or disks which are produced either with high isostatic pressure (HIP) or, simpler, a slurry technique. The objective was to perform a fatigue test and an in vitro wear simulation of two ceramics, yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) ceramic and a hybrid zirconium oxide-aluminum oxide ceramic, (ATZ) both produced either the classical way using high isostatic pressure (HIP, control) or with a slurry technique. MATERIALS AND METHODS: Ten discs/group were subjected to a cyclic biaxial fatigue test using a staircase approach under water at 37 °C in a dynamic universal testing machine. The 2-body wear test was performed on eight lapped 12 mm thick cylindrical samples subjected to spherical (ø 6 mm) leucite ceramic antagonists in a CS-4 chewing simulator at 49 N force and 0.7 mm lateral movement for 600 k cycles and 4167 thermal cycles (5-55 °C). Volumetric wear was calculated based on laser-scanned surfaces. Selected samples of both tests were viewed in SEM. RESULTS: All the ceramic specimens produced using the HIP method survived up to 1.2 M cycles with the maximum load of the equipment (1000 N) loading the specimens up to 1527 MPa. The fatigue limit stress at 1.2 M cycles for the Slurry ATZ samples was 946 MPa. For the Slurry Y-TZP samples the fatigue limit stress at 1.2 M cycles was 658 MPa. At 600 k cycles, all zirconium oxide ceramics showed no measurable wear and had a highly polished appearance. The leucite ceramic antagonists wear developed in a linear way. There was no difference between the materials produced with the slurry and the HIP process. ATZ ceramic produced significantly more wear than 3Y- TZP ceramic. CONCLUSIONS: The HIP method provided higher fatigue strength than the Slurry manufacturing method. All HIP ceramics surpassed the limit threshold (1527 MPa) of the testing machine. The tested ceramics did not show any measurable wear but had worn the leucite reinforced glass ceramic antagonists for a considerable amount.


Assuntos
Cerâmica , Zircônio , Teste de Materiais , Propriedades de Superfície , Zircônio/química , Cerâmica/química , Ítrio/química , Porcelana Dentária
15.
Materials (Basel) ; 15(7)2022 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-35407684

RESUMO

Traditional fatigue fracture theory and practice focus principally on structural design. It is thus too conservative and inappropriate when used to predict the high-cycle fatigue life of dies used for metal forming, especially cold forging. We propose a novel mean stress correction model and diagram to predict the high-cycle fatigue lives of cold forging dies, which focuses on the upper part of the equivalent fatigue strength curve. Considering the features of die materials characterized by high yield strength and low ductility, a straight line is assumed for the tensile yield line. To the contrary, a general curve is used to represent the fatigue strength. They are interpolated, based on the distance ratio, when finding an appropriate equivalent fatigue strength curve at the mean stress and stress amplitude between the line and curve. The approach is applied to a well-defined literature example to verify its validity and shed light on the characteristics of die fatigue life. The approach is also applied to practical forging and useful qualitative results are obtained.

16.
Materials (Basel) ; 14(11)2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34063927

RESUMO

The paper is focused on testing the weld of the S960MC steel produced at the micro-jet cooling under static and fatigue loading at critical parameters. This kind of material was in the form of a sheet with a thickness equal to 2 mm. The joint was obtained using three different types of welding wires: EDFK 1000, Union NiMoCr and Union X96 at the same parameters of the process. The joints were examined using non-destructive and destructive tests. The results from non-destructive experiments enable us to assess the quality of the welds directly before the joining process. In contrast, the destructive one allows following welds behavior under different loading conditions with their critical parameters. The bending experiments confirmed the good plastic properties of the weld, expressed by no cracks in the region tested in many variants of the joint manufactured. The results from static tests indicated a significant reduction of mechanical parameters of the weld in comparison to the base metal, expressed by 50% differences. Fatigue data have enabled us to follow the welding behavior at the increasing amplitude of axial stress up to fracture at constant amplitude value covering the following values of stress 650 MPa-100 MPa. Variations of total energy are presented at different values of several cycles up to fracture. Fracture regions are collected for analysis of the joint region features under cyclic loading. They have indicated differences in weld cracking depended on the stress level. Finally, the Wöhler S-N curve of the weld was determined, indicating the value of the fatigue limit of the weld tested, i.e., 100 MPa. The weld at the Union NiMoCr welding wire was indicated as the joint having the highest resistance on static and fatigue loadings.

17.
Materials (Basel) ; 13(22)2020 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-33218031

RESUMO

In this paper, infrared thermography was employed to study the fatigue process of AZ31B magnesium alloy. In order to eliminate the interference caused by the temperature rise of the fixture, a data processing method was proposed, which is based on a special model to describe the temperature change of the specimen. Based on the temperature data after processing, the temperature evolution indicates that AZ31B magnesium alloy has undergone cyclic hardening during fatigue. Three different temperature indicators were selected to evaluate the fatigue limit based on the evolution curve after processing. In addition, the experimental results showed that the temperature data processed by the proposed method can be used to estimate the fatigue limit of AZ31B magnesium alloy. Experiments were performed for both extrusion and transverse directions in consideration of the anisotropy of the AZ31B.

18.
J Mech Behav Biomed Mater ; 110: 103957, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32957248

RESUMO

OBJECTIVES: To evaluate and compare the fatigue behavior (fatigue limit and fatigue life) and damage modes of high-performance poly-ether-ketone-ketone (PEKK), zirconia and alloy bilayered crowns. MATERIALS AND METHODS: A total of 110 crowns (n = 50 for fatigue limit and n = 60 for fatigue life) were fabricated and used in this study. Pekkton® ivory discs, yttrium stabilized zirconia blanks and NiCr casting alloy were used to produce the respective PEKK, zirconia and alloy copings for crown fabrication. The prepared crowns were veneered with composite resin and subjected to fatigue tests. The fatigue limit was evaluated using the staircase method and the fatigue life of the samples was evaluated by subjecting the crowns to a load lower than the fatigue limit of that particular group, and also with an intermediate load of 522 N. A graphical plot was generated from the shape parameter (ß) and life parameter (α) values obtained through the Weibull analysis method. Kruskal-Wallis and Mann-Whitney tests were applied to determine the significance differences in the recorded fracture mode between the study groups. The damage modes of the samples were assessed using Burke's classification. RESULTS: The recorded fatigue limits of the groups were 442.8 ± 42.1 N, 608.7 ± 7.6 N, and 790.4 ± 29.2 N for zirconia, NiCr and PEKK, respectively. A significant difference in the fatigue limit of the groups was observed (p < 0.05). PEKK samples demonstrated the highest survival cycles of 1,170,000 and the lowest survival cycles was observed with zirconia samples at 100,000 under 522 N loading. The fracture modes in PEKK samples were largely distributed between code 1 and 2 whereas the fracture modes in NiCr group was distributed between code 1 and 4 and YZ crowns exhibited more of code 5 fractures. The difference in fracture modes among the groups was statistically significant (p < 0.05). CONCLUSION: The PEKK group demonstrated better results compared to zirconia and NiCr based crowns. The PEKK group demonstrated high fatigue limit and survived the highest fatigue life cycles among the tested groups.


Assuntos
Éter , Cetonas , Desenho Assistido por Computador , Coroas , Porcelana Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Ítrio , Zircônio
19.
Polymers (Basel) ; 12(11)2020 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-33202929

RESUMO

Polymeric joints, made of biomedical polyethylene (UHMWPE) nanocomposite sheets, were welded with a diode laser. Since polyethylene does not absorb laser light, nanocomposites were prepared containing different percentages by weight of titanium dioxide as it is a laser absorbent. The joints were first analyzed with static mechanical tests to establish the best percentage weight content of filler that had the best mechanical response. Then, the nanocomposites containing 1 wt% titanium dioxide were selected (white color) to be subjected to fatigue tests. The experimental results were also compared with those obtained on UMMWPE with a different laser light absorbent nano filler (carbon, with greater laser absorbing power, gray in color), already studied by our research team. The results showed that the two types of joints had an appreciable resistance to fatigue, depending on the various loads imposed. Therefore, they can be chosen in different applications of UHMWPE, depending on the stresses imposed during their use.

20.
Materials (Basel) ; 13(15)2020 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-32722201

RESUMO

Fatigue limit stress is a key design parameter for the structure fatigue design of composite materials. In this paper, a micromechanical fatigue limit stress model of fiber-reinforced ceramic-matrix composites (CMCs) subjected to stochastic overloading stress is developed. The fatigue limit stress of different carbon fiber-reinforced silicon carbide (C/SiC) composites (i.e., unidirectional (UD), cross-ply (CP), 2D, 2.5D, and 3D C/SiC) is predicted based on the micromechanical fatigue damage models and fatigue failure criterion. Under cyclic fatigue loading, the fatigue damage and fracture under stochastic overloading stress at different applied cycle numbers are characterized using two parameters of fatigue life decreasing rate and broken fiber fraction. The relationships between the fatigue life decreasing rate, stochastic overloading stress level and corresponding occurrence applied cycle number, and broken fiber fraction are analyzed. Under the same stochastic overloading stress level, the fatigue life decreasing rate increases with the occurrence applied cycle of stochastic overloading, and thus, is the highest for the cross-ply C/SiC composite and lowest for the 2.5D C/SiC composite. Among the UD, 2D, and 3D C/SiC composites, at the initial stage of cyclic fatigue loading, under the same stochastic overloading stress, the fatigue life decreasing rate of the 3D C/SiC is the highest; however, with the increasing applied cycle number, the fatigue life decreasing rate of the UD C/SiC composite is the highest. The broken fiber fraction increases when stochastic overloading stress occurs, and the difference of the broken fiber fraction between the fatigue limit stress and stochastic overloading stress level increases with the occurrence applied cycle.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA