Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Arch Orthop Trauma Surg ; 143(3): 1619-1626, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35179634

RESUMO

PURPOSE: Minimally invasive approaches (MIS) in total hip arthroplasty (THA) show inconsistent findings regarding planning adherence in digital templating. The purpose of this study is to evaluate any difference in planning adherence between the direct anterior approach (DAA) and an anterolateral MIS approach (AL MIS) in cementless short stem THA. METHODS: A single surgeon series of 222 THAs in 208 patients with an uncemented short curved stem and a bi-hemispherical acetabular cup were screened for inclusion. A total of 118 THAs were implanted via the DAA and 72 THAs via the AL MIS were included. The planning adherence for the offset option, stem size and the acetabular cup were retrospectively evaluated. RESULTS: Planning adherence for cup size (perfect match: p = 0.763; ± 1 size: p = 0.124), offset option (0.125) and stem size (perfect match: p = 0.275; ± 1 size: p = 0.552) did not show any statistical significance. Preoperative diagnosis of avascular necrosis of the femoral head in AL MIS approach (OR 6.045; CI 1.153-31.696) or mild hip dysplasia in the general cohort poses (OR 11.789; CI 1.386-100.293) a significant risk for inadequate prediction of the offset option. CONCLUSION: digital templating for THA with an uncemented short curved stem and a bi-hemispherical acetabular cup show comparable results between a direct anterior approach and a minimally invasive anterolateral approach in supine position. Surgeons should be aware of a low planning adherence for this type of short stem in minimally invasive approaches. CONCLUSION: Digital templating for THA with an uncemented short curved stem and a bi-hemispherical acetabular cup show comparable results between a direct anterior approach and a minimally invasive anterolateral approach in supine position. Surgeons should be aware of a low planning adherence for this type of short stem in minimally invasive approaches.


Assuntos
Artroplastia de Quadril , Luxação Congênita de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Acetábulo
2.
Arch Orthop Trauma Surg ; 143(1): 529-537, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35020039

RESUMO

PURPOSE: Varus positioning of the femoral stem can affect the hip offset (HO). The critical trochanter angle (CTA) was introduced in 2019 as a novel geometric angle, to predict varus stem alignment in cementless straight stem THA. The aim of this study was to evaluate the applicability of the CTA as a predictor for stem alignment in THA with a cementless neck resecting short stem. PATIENTS AND METHODS: In this retrospective study, 106 patients (index surgery 2014-2019) with unilateral THA and a morphologically healthy contralateral hip as a reference (Kellgren-Lawrence ≤ 1) were included. A cementless short stem with meta-diaphyseal fixation and press-fit cup was implanted in all cases. Stem alignment, CCD angle, CTA and offset reconstruction were measured on preoperative and 3 months postoperative AP radiographs of the pelvis. RESULTS: Preoperative lower CTA and lower CCD angle were positively correlated (r = 0.472; p < 0.001). Higher varus stem alignment is correlated with lower CTA (r = - 0.384; p < 0.001) and lower CCD angle (r = - 0.474; p < 0.001). A CTA of 23.1° or lower showed a sensitivity of 59.1% and a specificity of 87.1% (AUC: 0.733) and a CCD angle of 132.75° or lower a sensitivity of 68.2% and a specificity of 80.6% (AUC: 0.77) for a varus stem alignment > 3°. CONCLUSION: The CTA is also applicable in cementless THA with a neck resecting short stem to evaluate risk of intraoperative varus stem positioning. The CCD angle shows higher sensitivity with marginally lower specificity. Therefore, the CTA is not superior in predicting varus stem alignment in short-stem THA. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Estudos Retrospectivos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Radiografia , Desenho de Prótese
3.
Arch Orthop Trauma Surg ; 142(7): 1661-1668, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34169356

RESUMO

PURPOSE: Digital templating shows reliable accuracy for straight stem systems. In recent years, the implantation of short stems through minimally invasive approaches has gained more popularity. Minimally invasive approaches (MIS) show the risk of undersizing femoral components. Therefore, we questioned the planning adherence for a curved short stem and a bi-hemispherical acetabular cup implanted through an anterolateral MIS approach. METHODS: A consecutive series of 964 hips (index surgery between 2014 and 2019) with Fitmore® curved short stem and Allofit/-S® acetabular cup (both ZimmerBiomet Inc, Warsaw, IN) were included. Preoperative digital templating was conducted anterior-posterior (AP) digital radiographs of the hip using mediCAD® version 5.1 (Hectec GmbH, Altdorf, Germany). The templates of acetabular and femoral components (offset option and stem size) were retrospectively evaluated for general adherence, and according to sex, BMI and planner's experience. RESULTS: Planning adherence for the exact offset option was 70.6 and 21.6% for exact offset option and stem size. Adherence for acetabular cup ± 1 size was 74.8%. A significant difference between male and female patients for the offset option could be found (p = 0.03, z = -2983). In 22.5% of male patients, an offset option one size higher and in 12.3% of female patients an offset option one size smaller than templated was used intraoperatively CONCLUSION: Digital templating for the Fitmore® stem in cementless THA with a minimally invasive anterolateral approach shows comparable planning adherence to the existing literature for this cementless short stem. However, a lower planning adherence was detected compared to conventional straight stem systems. In male patients, the femoral offset is frequently undersized and in female patients frequently oversized compared to the preoperative plan. Surgeons should be aware of this difficulty in digital templating for Fitmore® hip stem.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Feminino , Quadril/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Masculino , Estudos Retrospectivos , Fatores Sexuais
4.
Int Orthop ; 42(9): 2077-2086, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29178044

RESUMO

PURPOSE: Short-stem hip arthroplasty (SHA) was designed to preserve bone stock and provide an improved load transfer. To gain more evidence regarding the load transfer, this review analysed the periprosthetic bone remodelling of SHA in comparison to standard hip arthroplasty (THA). METHODS: PubMed and ScienceDirect were screened to extract dual-energy X-ray absorptiometry (DXA) studies evaluating the periprosthetic bone remodelling of SHA and two proven THA designs. From the studies included, the postoperative change in periprosthetic bone mineral density (BMD) after one year and the trend over two years was determined. RESULTS: Fifteen studies with four SHAs (CFP, Metha, Nanos, Fitmore) and two THAs (CLS and Bicontact) designs were included. All SHA and THA stems revealed an initial decrease at the calcar and major trochanter (Gruen 1 and 7) with the Metha, Nanos and Fitmore showing a smaller and more balanced remodelling compared to THA. The pattern after one year and the trend over two years argue for a methaphyseal anchorage of the Metha and Nanos, whereas the Fitmore and CFP seem to anchor metha-diaphyseal. Clearly different pattern of bone remodelling were observed between all four SHAs. CONCLUSIONS: Periprosthetic bone remodelling is also present in SHA, with the main bone reduction observed proximally. However, certain SHA stems show a more balanced remodelling compared to THA, arguing for a favourable load transfer. Also, the femoral length where bone remodelling occurs is clearly shorter in SHA. As distinctively different pattern between the SHA designs were observed, they should not be judged as a single implant group.


Assuntos
Artroplastia de Quadril/efeitos adversos , Densidade Óssea/fisiologia , Remodelação Óssea/fisiologia , Prótese de Quadril/efeitos adversos , Absorciometria de Fóton/métodos , Feminino , Fêmur/cirurgia , Articulação do Quadril/cirurgia , Humanos , Masculino , Período Pós-Operatório , Desenho de Prótese/efeitos adversos
5.
Arch Orthop Trauma Surg ; 136(2): 277-84, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26739137

RESUMO

INTRODUCTION: Uncemented short, curved femoral stems may help save proximal bone stock during total hip arthroplasty (THA) and facilitate insertion in minimal invasive surgery. The aim of this 2 year, prospective, single-center study was to examine the stability and migration of the Fitmore (®) stem in THA using model-based radiostereometric analysis (RSA), and thus predict the implant's long-term survival. In addition, we evaluated the stem's clinical performance using standard clinical measures. PATIENTS AND METHODS: We conducted a prospective cohort study of 34 THA patients who received the short Fitmore Hip Stem (Zimmer, Winterthur, Switzerland). At 3, 6, 12 and 24 months postoperatively, the patients underwent clinical evaluation and radiostereometric analysis (RSA) to measure stem migration. RESULTS: RSA analysis revealed a mean subsidence of -0.39 mm (95 % CI -0.60 to -0.18) at 3 months with no further migration after 2 years. Mean internal rotation along the longitudinal axis was 1.09° (95 % CI 0.52-1.66) at 2 years, versus 0.85° (95 % CI 0.44-1.26) at 3 months. The Harris hip score improved from 60 (range 30-80) preoperatively to 99 (range 83-100) after 2 years. Three patients underwent revision due to deep infection, non-specific thigh pain and aseptic loosening in one case. CONCLUSION: We conclude that the Fitmore Hip Stem stabilizes after 3 months and achieves good short-term clinical results in most cases.


Assuntos
Artroplastia de Quadril , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Análise Radioestereométrica , Adulto , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados da Assistência ao Paciente , Desenho de Prótese , Adulto Jovem
6.
J Clin Densitom ; 17(2): 307-13, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24613452

RESUMO

Currently, an increasing number of younger patients undergo total hip arthroplasty surgery. This has led to a minimal invasive approach and the use of short, bone preserving, femoral stems. In this study, we sought to evaluate osseointegration of the Fitmore stem (Zimmer, Inc; Warsaw, IN) during the first 12 mo after surgery, which reflects the biological phenomenon of osseointegration with radiographic evaluation and bone densitometry (dual-energy X-ray absorptiometry). We evaluated 33 patients (mean age 62.3) using dual-energy X-ray absorptiometry scan around the stem and X-ray. Moreover, we studied functional recovery using the Harris Hip Score, timed up and go test, and a quality of life form (SF-36), during the follow-up period. At 12 mo, we observed an increased periprosthetic bone mineral density in region of interest 1 (1.7%) and region of interest 7 (8.3%), where there is usually a greater amount of bone resorption. Also Harris Hip Score, timed up and go test, and SF-36 showed an improvement of clinical conditions of all patients. We also used a control group with a standard stem implanted. Because this is the first study correlating osseointegration and clinical outcome of the Fitmore stem, further clinical studies will be necessary to confirm good/positive results and a long stable fixation.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osseointegração , Desenho de Prótese , Absorciometria de Fóton , Feminino , Indicadores Básicos de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia
7.
J Orthop Surg Res ; 18(1): 893, 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-37993946

RESUMO

BACKGROUND: Short stems were introduced into total hip arthroplasty (THA) to preserve bone stock, to transmit more load to the proximal femur, and to enable minimal invasive approaches. This study is the first long-term study (with a follow-up of 10 years) of the survival as well as the clinical and radiographic outcomes of the Fitmore hip stem, a short curved uncemented stem. METHODS: In total, 123 Fitmore hip stems were prospectively evaluated. At the final 10-year follow-up, 80 Fitmore stems (78 patients: 30 female, 48 male) were eligible for evaluation. Clinical parameters were thigh pain, EQ-5D, Harris Hip Score (HHS) and Oxford Hip Score. Radiographic parameters were cortical hypertrophy (CH), bone condensation, cortical thinning, radiolucency, reactive lines, calcar rounding, calcar resorption, subsidence and varus/valgus position. RESULTS: After 10 years, there was a survival rate of 99% (1 revision because of aseptic stem loosening). HHS had improved from 59 to 94 and Oxford Hip Score from 22 to 43. CH rate after 1 year was 69% and after 10 years 74%. In the first year, radiolucency was found in 58% and in 17.5% after 10 years. Subsidence after 1 year was 1.6 ± 1.6 mm and 5.0 ± 3.1 mm after 10 years. CONCLUSIONS: The Fitmore hip stem showed a survival rate of 99% as well as good clinical and radiographic outcomes in the long-term follow-up of 10 years.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Masculino , Feminino , Artroplastia de Quadril/métodos , Hipertrofia , Fêmur/cirurgia , Osso e Ossos/cirurgia , Desenho de Prótese , Seguimentos , Resultado do Tratamento
8.
J Orthop Surg Res ; 14(1): 156, 2019 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-31133027

RESUMO

BACKGROUND: An increased occurrence of cortical hypertrophy (CH) was observed 1-2 years after implanting short curved Fitmore hip stems. There are no published data about either the clinical relevance or the progression of CH over the long term. METHODS: Ninety-six primary total hip arthroplasties were performed between 2008 and 2010 using the Fitmore hip stem. Clinical and radiological parameters were recorded preoperatively and at 1, 2, 3, and 5 year follow-up. RESULTS: CH appeared mainly on antero-posterior radiographs in Gruen Zones 2, 3, 5, and 6. After 1 year, the diameter was 10 ± 2 mm and remained constant thereafter. The CH rate after 1 year was 69% and after 5 years 71%. Subsidence after 1 year was 1.6 ± 1.55 mm and 1.93 ± 1.72 mm after 5 years. Cortical thinning was 46% after 1 year and 56% after 5 years, mainly in Gruen Zones 7 and 8. In the first year radiolucencies were found in 51% in all Gruen Zones, and in 20% after 5 years. Patient, implant, and surgical factors did not correlate with radiological outcomes except that larger stems had more CH. After 5 years, the Harris Hip Score had improved from 59 to 94 and the Oxford Hip Score from 22 to 41. Radiographic parameters, notably CH, were not associated with clinical outcomes except that cortical thinning correlated with lower outcome scores. CONCLUSIONS: CH correlated neither with clinical outcome nor with patient, surgical or implant factors, except for a positive correlation with stem size. The Fitmore hip stems settled within the first year to a stable fixation and then remained almost unchanged. However, cortical thinning is common in Gruen Zone 7 and 8 meaning that there is stress-shielding.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/tendências , Osso Cortical/diagnóstico por imagem , Prótese de Quadril/tendências , Hiperostose/diagnóstico por imagem , Desenho de Prótese/tendências , Idoso , Estudos de Coortes , Feminino , Seguimentos , Prótese de Quadril/normas , Humanos , Hiperostose/etiologia , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA