Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Compr Psychiatry ; 129: 152447, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38134553

RESUMO

BACKGROUND: Personalization is considered an important principle in virtual reality (VR) exposure therapy. We aimed to identify whether personalized VR exposure could provoke increased anxiety in patients with panic disorder and agoraphobia as it is considered the first step in successful treatment for anxiety. METHODS: We performed a double-arm, one-day preliminary study among 28 patients with panic disorder and agoraphobia. Three sessions of VR exposure, including a theater, train, and elevator scenario, were conducted in two groups. In the personalized group (n = 14), the brightness and crowd density were customized based on a pre-assessment. In the control group (n = 14), these conditions were fully randomized. Self-reported anxiety, heart rate, skin conductance, and electroencephalography were measured before, during, and after the VR sessions. RESULTS: In the later VR sessions, higher self-reported anxiety levels measured by the Visual Analogue Scale were observed in the personalized exposure group. Increased heart rates during and after the VR sessions were observed in the personalized group. The changes in skin conductance peaks were not significantly different between the groups, but the increase in skin conductance was associated with the participants' perception of presence. The electroencephalogram showed widespread increases in alpha waves in the frontal and temporal areas of the brain in the personalized group than in the control group. CONCLUSION: Personalized VR exposure elicits stronger anxiogenic effects in patients with panic disorder and agoraphobia as suggested by self-report and neurophysiological data. Personalization of VR exposure has the potential for effective behavioral therapy.


Assuntos
Transtorno de Pânico , Realidade Virtual , Humanos , Transtorno de Pânico/diagnóstico , Transtorno de Pânico/terapia , Agorafobia/diagnóstico , Agorafobia/terapia , Ansiedade/terapia , Transtornos de Ansiedade
2.
Eur J Appl Physiol ; 124(1): 317-327, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37505231

RESUMO

PURPOSE: Menthol is known to elicit opposing thermoregulatory and perceptual alterations during intense exercise. The current purpose was to determine the thermoregulatory and perceptual effects of topical menthol application prior to walking in the heat. METHODS: Twelve participants walked (1.6 m s-1, 5% grade) for 30 min in the heat (38 °C, 60% relative humidity) with either a 4% menthol or control gel on the upper (shoulder to wrist) and lower (mid-thigh to ankle) limbs. Skin blood flow (SkBF), sweat (rate, composition), skin conductivity, heart rate, temperature (skin, core), and thermal perception were measured prior to and during exercise. RESULTS: Skin conductivity expressed as time to 10, 20, 30, and 40 µS was delayed due to menthol (559 ± 251, 770 ± 292, 1109 ± 301, 1299 ± 335 s, respectively) compared to the control (515 ± 260, 735 ± 256, 935 ± 300, 1148 ± 298 s, respectively, p = 0.048). Sweat rate relative to body surface area was lower due to menthol (0.55 ± 0.16 L h-1 m(2)-1) than the control (0.64 ± 0.16 L h-1 m(2)-1, p = 0.049). Core temperature did not differ at baseline between the menthol (37.4 ± 0.3 °C) and control (37.3 ± 0.4 °C, p = 0.298) but was higher at 10, 20, and 30 min due to menthol (37.5 ± 0.3, 37.7 ± 0.2, 38.1 ± 0.3 °C, respectively) compared to the control (37.3 ± 0.4, 37.4 ± 0.3, 37.7 ± 0.3 °C, respectively, p < 0.05). The largest rise in core temperature from baseline was at 30 min during menthol (0.7 ± 0.3 °C) compared to the control (0.4 ± 0.2 °C, p = 0.004). Overall, the menthol treatment was perceived cooler, reaching "slightly warm" whereas the control treatment reached "warm" (p < 0.001). CONCLUSION: Menthol application to the limbs impairs whole-body thermoregulation while walking in the heat despite perceiving the environment as cooler.


Assuntos
Temperatura Alta , Mentol , Humanos , Mentol/farmacologia , Regulação da Temperatura Corporal/fisiologia , Sudorese , Temperatura Cutânea , Caminhada , Percepção/fisiologia
3.
Sensors (Basel) ; 24(14)2024 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-39065963

RESUMO

Electrodermal Activity (EDA), which primarily indicates arousal through sympathetic nervous system activity, serves as a tool to measure constructs like engagement, cognitive load, performance, and stress. Despite its potential, empirical studies have often yielded mixed results and found it of limited use. To better understand EDA, we conducted a mixed-methods study in which quantitative EDA profiles and survey data were investigated using qualitative interviews. This study furnishes an EDA dataset measuring the engagement levels of seven participants who watched three videos for 4-10 min. The subsequent interviews revealed five EDA morphologies with varying short-term signatures and long-term trends. We used this dataset to demonstrate the moving average crossover, a novel metric for EDA analysis, in predicting engagement-disengagement dynamics in such data. Our contributions include the creation of the detailed dataset, comprising EDA profiles annotated with qualitative data, the identification of five distinct EDA morphologies, and the proposition of the moving average crossover as an indicator of the beginning of engagement or disengagement in an individual.


Assuntos
Resposta Galvânica da Pele , Humanos , Resposta Galvânica da Pele/fisiologia , Masculino , Feminino , Adulto , Adulto Jovem , Nível de Alerta/fisiologia
4.
Sensors (Basel) ; 24(13)2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-39000810

RESUMO

The current study investigated the effectiveness of social robots in facilitating stress management interventions for university students by evaluating their physiological responses. We collected electroencephalogram (EEG) brain activity and Galvanic Skin Responses (GSRs) together with self-reported questionnaires from two groups of students who practiced a deep breathing exercise either with a social robot or a laptop. From GSR signals, we obtained the change in participants' arousal level throughout the intervention, and from the EEG signals, we extracted the change in their emotional valence using the neurometric of Frontal Alpha Asymmetry (FAA). While subjective perceptions of stress and user experience did not differ significantly between the two groups, the physiological signals revealed differences in their emotional responses as evaluated by the arousal-valence model. The Laptop group tended to show a decrease in arousal level which, in some cases, was accompanied by negative valence indicative of boredom or lack of interest. On the other hand, the Robot group displayed two patterns; some demonstrated a decrease in arousal with positive valence indicative of calmness and relaxation, and others showed an increase in arousal together with positive valence interpreted as excitement. These findings provide interesting insights into the impact of social robots as mental well-being coaches on students' emotions particularly in the presence of the novelty effect. Additionally, they provide evidence for the efficacy of physiological signals as an objective and reliable measure of user experience in HRI settings.


Assuntos
Eletroencefalografia , Emoções , Resposta Galvânica da Pele , Saúde Mental , Robótica , Estresse Psicológico , Humanos , Robótica/métodos , Masculino , Feminino , Emoções/fisiologia , Eletroencefalografia/métodos , Estresse Psicológico/terapia , Estresse Psicológico/fisiopatologia , Resposta Galvânica da Pele/fisiologia , Adulto Jovem , Adulto , Inquéritos e Questionários , Nível de Alerta/fisiologia , Estudantes/psicologia
5.
J Therm Biol ; 121: 103828, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38604115

RESUMO

Heating, Ventilation, and Air Conditioning (HVAC) systems in high-speed trains (HST) are responsible for consuming approximately 70% of non-operational energy sources, yet they frequently fail to ensure provide adequate thermal comfort for the majority of passengers. Recent advancements in portable wearable sensors have opened up new possibilities for real-time detection of occupant thermal comfort status and timely feedback to the HVAC system. However, since occupant thermal comfort is subjective and cannot be directly measured, it is generally inferred from thermal environment parameters or physiological signals of occupants within the HST compartment. This paper presents a field test conducted to assess the thermal comfort of occupants within HST compartments. Leveraging physiological signals, including skin temperature, galvanic skin reaction, heart rate, and ambient temperature, we propose a Predicted Thermal Comfort (PTC) model for HST cabin occupants and establish an intelligent regulation model for the HVAC system. Nine input factors, comprising physiological signals, individual physiological characteristics, compartment seating, and ambient temperature, were formulated for the PTS model. In order to obtain an efficient and accurate PTC prediction model for HST cabin occupants, we compared the accuracy of different subsets of features trained by Machine Learning (ML) models of Random Forest, Decision Tree, Vector Machine and K-neighbourhood. We divided all the predicted feature values into four subsets, and did hyperparameter optimisation for each ML model. The HST compartment occupant PTC prediction model trained by Random Forest model obtained 90.4% Accuracy (F1 macro = 0.889). Subsequent sensitivity analyses of the best predictive models were then performed using SHapley Additive explanation (SHAP) and data-based sensitivity analysis (DSA) methods. The development of a more accurate and operationally efficient thermal comfort prediction model for HST occupants allows for precise and detailed feedback to the HVAC system. Consequently, the HVAC system can make the most appropriate and effective air supply adjustments, leading to improved satisfaction rates for HST occupant thermal comfort and the avoidance of energy wastage caused by inaccurate and untimely predictive feedback.


Assuntos
Aprendizado de Máquina , Temperatura Cutânea , Humanos , Ar Condicionado/instrumentação , Ar Condicionado/métodos , Frequência Cardíaca , Resposta Galvânica da Pele , Sensação Térmica , Temperatura , Masculino
6.
Wilderness Environ Med ; 35(1): 36-43, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38379484

RESUMO

INTRODUCTION: Capsaicin, a chili pepper extract, can stimulate increased skin blood flow (SkBF) with a perceived warming sensation on application areas. Larger surface area application may exert a more systemic thermoregulatory response. Capsaicin could assist with maintaining heat transport to the distal extremities, minimizing cold weather injury risk. However, the thermoregulatory and perceptual impact of topical capsaicin cream application prior to exercise in the cold is unknown. METHODS: Following application of either a 0.1% capsaicin or control cream to the upper and lower extremities (10 g total, ∼40-50% body surface area), 11 participants in shorts and a t-shirt were exposed to 30 min of cold (0 °C, 40% relative humidity). Exposures comprised of 5 min seated rest, 20 min walking (1.6 m·s-1, 5% grade), and 5 min seated rest. Temperature (skin, core), SkBF, skin conductivity, heart rate, thermal sensation, and thermal comfort were measured throughout. RESULTS: The capsaicin treatment did not differ from the control treatment in skin temperature (treatment mean: 30.0 ± 2.5, 30.1 ± 2.4 °C, respectively, p = 0.655), core temperature (treatment mean: 37.3 ± 0.5, 37.4 ± 0.4 °C, respectively, p = 0.113), SkBF (treatment mean: -8.4 ± 10.0, -11.1 ± 10.7 A.U., respectively, p = 0.492), skin conductivity (treatment mean: -0.7 ± 5.1, 0.4 ± 6.4 µS, respectively, p = 0.651), or heart rate (treatment mean: 83 ± 29, 85 ± 28 beats·minute-1, respectively, p = 0.234). The capsaicin and control treatments also did not differ in thermal sensation (p = 0.521) and thermal comfort (p = 0.982), with perceptual outcomes corresponding with feeling "cool" and "just uncomfortable," respectively. CONCLUSIONS: 0.1% topical capsaicin application to exposed limbs prior to walking in a cold environment does not alter whole-body thermoregulation or thermal perception.


Assuntos
Capsaicina , Temperatura Baixa , Humanos , Capsaicina/farmacologia , Caminhada , Regulação da Temperatura Corporal , Percepção
7.
Proc Natl Acad Sci U S A ; 117(45): 27906-27915, 2020 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-33106394

RESUMO

Soft microfluidic systems that capture, store, and perform biomarker analysis of microliter volumes of sweat, in situ, as it emerges from the surface of the skin, represent an emerging class of wearable technology with powerful capabilities that complement those of traditional biophysical sensing devices. Recent work establishes applications in the real-time characterization of sweat dynamics and sweat chemistry in the context of sports performance and healthcare diagnostics. This paper presents a collection of advances in biochemical sensors and microfluidic designs that support multimodal operation in the monitoring of physiological signatures directly correlated to physical and mental stresses. These wireless, battery-free, skin-interfaced devices combine lateral flow immunoassays for cortisol, fluorometric assays for glucose and ascorbic acid (vitamin C), and digital tracking of skin galvanic responses. Systematic benchtop evaluations and field studies on human subjects highlight the key features of this platform for the continuous, noninvasive monitoring of biochemical and biophysical correlates of the stress state.


Assuntos
Técnicas Biossensoriais/instrumentação , Microfluídica/métodos , Suor/química , Espectroscopia Dielétrica/instrumentação , Espectroscopia Dielétrica/métodos , Impedância Elétrica , Desenho de Equipamento/instrumentação , Desenho de Equipamento/métodos , Fluorometria , Humanos , Imunoensaio , Dispositivos Lab-On-A-Chip , Pele/química , Dispositivos Eletrônicos Vestíveis
8.
Sensors (Basel) ; 23(2)2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36679418

RESUMO

Wearable devices have been shown to play an important role in disease prevention and health management, through the multimodal acquisition of peripheral biosignals. However, many of these wearables are exposed, limiting their long-term acceptability by some user groups. To overcome this, a wearable smart sock integrating a PPG sensor and an EDA sensor with textile electrodes was developed. Using the smart sock, EDA and PPG measurements at the foot/ankle were performed in test populations of 19 and 15 subjects, respectively. Both measurements were validated by simultaneously recording the same signals with a standard device at the hand. For the EDA measurements, Pearson correlations of up to 0.95 were obtained for the SCL component, and a mean consensus of 69% for peaks detected in the two locations was obtained. As for the PPG measurements, after fine-tuning the automatic detection of systolic peaks, the index finger and ankle, accuracies of 99.46% and 87.85% were obtained, respectively. Moreover, an HR estimation error of 17.40±14.80 Beats-Per-Minute (BPM) was obtained. Overall, the results support the feasibility of this wearable form factor for unobtrusive EDA and PPG monitoring.


Assuntos
Resposta Galvânica da Pele , Dispositivos Eletrônicos Vestíveis , Humanos , Fotopletismografia/métodos , Estudos de Viabilidade , , Frequência Cardíaca
9.
Sensors (Basel) ; 23(8)2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-37112345

RESUMO

The majority of car accidents worldwide are caused by drowsy drivers. Therefore, it is important to be able to detect when a driver is starting to feel drowsy in order to warn them before a serious accident occurs. Sometimes, drivers are not aware of their own drowsiness, but changes in their body signals can indicate that they are getting tired. Previous studies have used large and intrusive sensor systems that can be worn by the driver or placed in the vehicle to collect information about the driver's physical status from a variety of signals that are either physiological or vehicle-related. This study focuses on the use of a single wrist device that is comfortable for the driver to wear and appropriate signal processing to detect drowsiness by analyzing only the physiological skin conductance (SC) signal. To determine whether the driver is drowsy, the study tests three ensemble algorithms and finds that the Boosting algorithm is the most effective in detecting drowsiness with an accuracy of 89.4%. The results of this study show that it is possible to identify when a driver is drowsy using only signals from the skin on the wrist, and this encourages further research to develop a real-time warning system for early detection of drowsiness.


Assuntos
Condução de Veículo , Vigília/fisiologia , Algoritmos , Conscientização , Aprendizado de Máquina
10.
J Clin Monit Comput ; 37(6): 1573-1584, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37195623

RESUMO

Monitoring of high-risk patients in hospital wards is crucial in identifying and preventing clinical deterioration. Sympathetic nervous system activity measured continuously and non-invasively by Electrodermal activity (EDA) may relate to complications, but the clinical use remains untested. The aim of this study was to explore associations between deviations of EDA and subsequent serious adverse events (SAE). Patients admitted to general wards after major abdominal cancer surgery or with acute exacerbation of chronic obstructive pulmonary disease were continuously EDA-monitored for up to 5 days. We used time-perspectives consisting of 1, 3, 6, and 12 h of data prior to first SAE or from start of monitoring. We constructed 648 different EDA-derived features to assess EDA. The primary outcome was any SAE and secondary outcomes were respiratory, infectious, and cardiovascular SAEs. Associations were evaluated using logistic regressions with adjustment for relevant confounders. We included 714 patients and found a total of 192 statistically significant associations between EDA-derived features and clinical outcomes. 79% of these associations were EDA-derived features of absolute and relative increases in EDA and 14% were EDA-derived features with normalized EDA above a threshold. The highest F1-scores for primary outcome with the four time-perspectives were 20.7-32.8%, with precision ranging 34.9-38.6%, recall 14.7-29.4%, and specificity 83.1-91.4%. We identified statistically significant associations between specific deviations of EDA and subsequent SAE, and patterns of EDA may be developed to be considered indicators of upcoming clinical deterioration in high-risk patients.


Assuntos
Deterioração Clínica , Resposta Galvânica da Pele , Humanos , Estudos de Coortes , Sistema Nervoso Simpático/fisiologia
11.
Acta Neuropsychiatr ; : 1-11, 2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-36960675

RESUMO

BACKGROUND: Chronic stress responses can lead to physical and behavioural health problems, often experienced and observed in the care of people with intellectual disabilities or people with dementia. Electrodermal activity (EDA) is a bio-signal for stress, which can be measured by wearables and thereby support stress management. However, the how, when and to what extent patients and healthcare providers can benefit is unclear. This study aims to create an overview of available wearables enabling the detection of perceived stress by using EDA. METHODS: Following the PRISMA-SCR protocol for scoping reviews, four databases were included in the search of peer-reviewed studies published between 2012 and 2022, reporting detection of EDA in relation to self-reported stress or stress-related behaviours. Type of wearable, bodily location, research population, context, stressor type and the reported relationship between EDA and perceived stress were extracted. RESULTS: Of the 74 included studies, the majority included healthy subjects in laboratory situations. Field studies and studies using machine learning (ML) to predict stress have increased in the last years. EDA is most often measured on the wrist, with offline data processing. Studies predicting perceived stress or stress-related behaviour using EDA features, reported accuracies between 42% and 100% with an average of 82.6%. Of these studies, the majority used ML. CONCLUSION: Wearable EDA sensors are promising in detecting perceived stress. Field studies with relevant populations in a health or care context are lacking. Future studies should focus on the application of EDA-measuring wearables in real-life situations to support stress management.

12.
Sensors (Basel) ; 22(19)2022 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-36236461

RESUMO

The ability to monitor mental effort during a task using a wearable sensor may improve productivity for both work and study. The use of the electrodermal activity (EDA) signal for tracking mental effort is an emerging area of research. Through analysis of over 92 h of data collected with the Empatica E4 on a single participant across 91 different activities, we report on the efficacy of using EDA features getting at signal intensity, signal dispersion, and peak intensity for prediction of the participant's self-reported mental effort. We implemented the logistic regression algorithm as an interpretable machine learning approach and found that features related to signal intensity and peak intensity were most useful for the prediction of whether the participant was in a self-reported high mental effort state; increased signal and peak intensity were indicative of high mental effort. When cross-validated by activity moderate predictive efficacy was achieved (AUC = 0.63, F1 = 0.63, precision = 0.64, recall = 0.63) which was significantly stronger than using the model bias alone. Predicting mental effort using physiological data is a complex problem, and our findings add to research from other contexts showing that EDA may be a promising physiological indicator to use for sensor-based self-monitoring of mental effort throughout the day. Integration of other physiological features related to heart rate, respiration, and circulation may be necessary to obtain more accurate predictions.


Assuntos
Resposta Galvânica da Pele , Aprendizado de Máquina , Algoritmos , Frequência Cardíaca , Humanos , Monitorização Fisiológica
13.
Sensors (Basel) ; 21(2)2021 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-33430220

RESUMO

Sleep is an essential element to human life, restoring the brain and body from accumulated fatigue from daily activities. Quantitative monitoring of daily sleep quality can provide critical feedback to evaluate human health and life patterns. However, the existing sleep assessment system using polysomnography is not available for a home sleep evaluation, while it requires multiple sensors, tabletop electronics, and sleep specialists. More importantly, the mandatory sleep in a designated lab facility disrupts a subject's regular sleep pattern, which does not capture one's everyday sleep behaviors. Recent studies report that galvanic skin response (GSR) measured on the skin can be one indicator to evaluate the sleep quality daily at home. However, the available GSR detection devices require rigid sensors wrapped on fingers along with separate electronic components for data acquisition, which can interrupt the normal sleep conditions. Here, we report a new class of materials, sensors, electronics, and packaging technologies to develop a wireless, soft electronic system that can measure GSR on the wrist. The single device platform that avoids wires, rigid sensors, and straps offers the maximum comfort to wear on the skin and minimize disruption of a subject's sleep. A nanomaterial GSR sensor, printed on a soft elastomeric membrane, can have intimate contact with the skin to reduce motion artifact during sleep. A multi-layered flexible circuit mounted on top of the sensor provides a wireless, continuous, real-time recording of GSR to classify sleep stages, validated by the direct comparison with the standard method that measures other physiological signals. Collectively, the soft bioelectronic system shows great potential to be working as a portable, at-home sensor system for assessing sleep quality before a hospital visit.


Assuntos
Dispositivos Eletrônicos Vestíveis , Eletrônica , Resposta Galvânica da Pele , Humanos , Polissonografia , Fases do Sono
14.
Sensors (Basel) ; 21(3)2021 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-33498830

RESUMO

Wearable sensors are nowadays largely employed to assess physiological signals derived from the human body without representing a burden in terms of obtrusiveness. One of the most intriguing fields of application for such systems include the assessment of physiological responses to sensory stimuli. In this specific regard, it is not yet known which are the main psychophysiological drivers of olfactory-related pleasantness, as the current literature has demonstrated the relationship between odor familiarity and odor valence, but has not clarified the consequentiality between the two domains. Here, we enrolled a group of university students to whom olfactory training lasting 3 months was administered. Thanks to the analysis of electrocardiogram (ECG) and galvanic skin response (GSR) signals at the beginning and at the end of the training period, we observed different autonomic responses, with higher parasympathetically-mediated response at the end of the period with respect to the first evaluation. This possibly suggests that an increased familiarity to the proposed stimuli would lead to a higher tendency towards relaxation. Such results could suggest potential applications to other domains, including personalized treatments based on odors and foods in neuropsychiatric and eating disorders.


Assuntos
Olfato , Dispositivos Eletrônicos Vestíveis , Sistema Nervoso Autônomo , Resposta Galvânica da Pele , Humanos , Odorantes
15.
Sensors (Basel) ; 21(7)2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33808147

RESUMO

Mental stress can lead to traffic accidents by reducing a driver's concentration or increasing fatigue while driving. In recent years, demand for methods to detect drivers' stress in advance to prevent dangerous situations increased. Thus, we propose a novel method for detecting driving stress using nonlinear representations of short-term (30 s or less) physiological signals for multimodal convolutional neural networks (CNNs). Specifically, from hand/foot galvanic skin response (HGSR, FGSR) and heart rate (HR) short-term input signals, first, we generate corresponding two-dimensional nonlinear representations called continuous recurrence plots (Cont-RPs). Second, from the Cont-RPs, we use multimodal CNNs to automatically extract FGSR, HGSR, and HR signal representative features that can effectively differentiate between stressed and relaxed states. Lastly, we concatenate the three extracted features into one integrated representation vector, which we feed to a fully connected layer to perform classification. For the evaluation, we use a public stress dataset collected from actual driving environments. Experimental results show that the proposed method demonstrates superior performance for 30-s signals, with an overall accuracy of 95.67%, an approximately 2.5-3% improvement compared with that of previous works. Additionally, for 10-s signals, the proposed method achieves 92.33% classification accuracy, which is similar to or better than the performance of other methods using long-term signals (over 100 s).


Assuntos
Condução de Veículo , Redes Neurais de Computação , Acidentes de Trânsito , Resposta Galvânica da Pele , Frequência Cardíaca
16.
Sensors (Basel) ; 21(11)2021 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-34071556

RESUMO

The theory of modern organizations considers emotional intelligence to be the metric for tools that enable organizations to create a competitive vision. It also helps corporate leaders enthusiastically adhere to the vision and energize organizational stakeholders to accomplish the vision. In this study, the one-dimensional convolutional neural network classification model is initially employed to interpret and evaluate shifts in emotion over a period by categorizing emotional states that occur at particular moments during mutual interaction using physiological signals. The self-organizing map technique is implemented to cluster overall organizational emotions to represent organizational competitiveness. The analysis of variance test results indicates no significant difference in age and body mass index for participants exhibiting different emotions. However, a significant mean difference was observed for the blood volume pulse, galvanic skin response, skin temperature, valence, and arousal values, indicating the effectiveness of the chosen physiological sensors and their measures to analyze emotions for organizational competitiveness. We achieved 99.8% classification accuracy for emotions using the proposed technique. The study precisely identifies the emotions and locates a connection between emotional intelligence and organizational competitiveness (i.e., a positive relationship with employees augments organizational competitiveness).


Assuntos
Emoções , Redes Neurais de Computação , Algoritmos , Nível de Alerta , Resposta Galvânica da Pele , Humanos
17.
Sensors (Basel) ; 21(12)2021 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-34205302

RESUMO

The galvanic skin response (GSR; also widely known as electrodermal activity (EDA)) is a signal for stress-related studies. Given the sparsity of studies related to the GSR and the variety of devices, this study was conducted at the Human Health Activity Laboratory (H2AL) with 17 healthy subjects to determine the variability in the detection of changes in the galvanic skin response among a test group with heterogeneous respondents facing pleasant and unpleasant stimuli, correlating the GSR biosignals measured from different body sites. We experimented with the right and left wrist, left fingers, the inner side of the right foot using Shimmer3GSR and Empatica E4 sensors. The results indicated the most promising homogeneous places for measuring the GSR, namely, the left fingers and right foot. The results also suggested that due to a significantly strong correlation among the inner side of the right foot and the left fingers, as well as the moderate correlations with the right and left wrists, the foot may be a suitable place to homogenously measure a GSR signal in a test group. We also discuss some possible causes of weak and negative correlations from anomalies detected in the raw data possibly related to the sensors or the test group, which may be considered to develop robust emotion detection systems based on GRS biosignals.


Assuntos
Emoções , Resposta Galvânica da Pele , Humanos , Punho
18.
Sensors (Basel) ; 20(16)2020 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-32824477

RESUMO

In traditional Chinese medicine (TCM), pulse diagnosis is one of the most important methods for diagnosis. A pulse can be felt by applying firm fingertip pressure to the skin where the arteries travel. The pulse diagnosis has become an important tool not only for TCM practitioners but also for several areas of Western medicine. Many pulse measuring devices have been proposed to obtain objective pulse conditions. In the past, pulse diagnosis instruments were single-point sensing methods, which missed a lot of information. Later, multi-point sensing instruments were developed that resolved this issue but were much higher in cost and lacked mobility. In this article, based on the concept of sensor fusion, we describe a portable low-cost system for TCM pulse-type estimation using a smartphone connected to two sensors, including one photoplethysmography (PPG) sensor and one galvanic skin response (GSR) sensor. As a proof of concept, we collected five-minute PPG pulse information and skin impedance on 24 acupoints from 80 subjects. Based on these collected data, we implemented a fully connected neural network (FCN), which was able to provide high prediction accuracy (>90%) for patients with a TCM wiry pulse.


Assuntos
Pontos de Acupuntura , Medicina Tradicional Chinesa , Smartphone , Impedância Elétrica , Estudos de Viabilidade , Humanos
19.
J Med Syst ; 45(1): 1, 2020 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-33236166

RESUMO

The neurological status of patients in the Intensive Care Units (ICU) is determined by the Glasgow Coma Scale (GCS). Patients in coma are thought to be unaware of what is happening around them. However, many studies show that the family plays an important role in the recovery of the patient and is a great emotional resource. In this study, Galvanic Skin Response (GSR) signals were analyzed from 31 patients with low consciousness levels between GCS 3 and 8 to determine relationship between consciousness level and GSR signals as a new approach. The effect of family and nurse on unconscious patients was investigated by GSR signals recorded with a new proposed protocol. The signals were recorded during conversation and touching of the patient by the nurse and their families. According to numerical results, the level of consciousness can be separated using GSR signals. Also, it was found that family and nurse had statistically significant effects on the patient. Patients with GCS 3,4, and 5 were considered to have low level of consciousness, while patients with GCS 6,7, and 8 were considered to have high level of consciousness. According to our results, it is obtained lower GSR amplitude in low GCS (3, 4, 5) compared to high GCS (7, 8). It was concluded that these patients were aware of therapeutic affect although they were unconscious. During the classification stage of this study, the class imbalance problem, which is common in medical diagnosis, was solved using Synthetic Minority Over-Sampling Technique (SMOTE), Adaptive Synthetic Sampling (ADASYN) and random oversampling methods. In addition, level of consciousness was classified with 92.7% success using various decision tree algorithms. Random Forest was the method which provides higher accuracy compared to all other methods. The obtained results showed that GSR signal analysis recorded in different stages gives very successful GCS score classification performance according to literature studies.


Assuntos
Estado de Consciência , Resposta Galvânica da Pele , Coma , Escala de Coma de Glasgow , Humanos , Inconsciência
20.
Anim Cogn ; 22(3): 365-372, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30788671

RESUMO

"Audience effect" is the influence of an audience size or composition on the emotional state of a public speaker. One characteristic of the audience which has received little attention is the spatial position of observers. We tested the influence of three positions (frontal, bi-frontal, and quadri-frontal) on actors and spectators' emotions in real theatrical representations. Measurements consisted in self-report questionnaires and galvanic skin responses. The layout of the theatre hall influenced both cognitive and physiological components of emotions. Actors were more influenced than spectators and showed an overall accuracy in self-perception. The quadri-frontal audience received the highest scores in actors' feeling assessments and galvanic skin responses. In addition, we found a discrepancy between self-assessment of emotional states by spectators and how actors perceive them. Attention should thus be paid in the layout of performance places with obviously more attention from the public and better feelings for actors in more dispersed settings.


Assuntos
Emoções , Autoimagem , Fala , Animais , Emoções/fisiologia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA