Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 181
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Eur J Neurol ; 30(3): 729-740, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36409153

RESUMO

BACKGROUND AND PURPOSE: This study evaluates the quantitative measurability of glial fibrillary acidic protein (GFAP), neurofilament light chain (NfL), ubiquitin carboxy-terminal hydrolase L1 (UCH-L1) and total tau (t-tau) in urine of patients with acute cerebral damage. METHODS: Serum and urine samples were prospectively collected from patients with an acute ischemic stroke or intracerebral hemorrhage (target group) and compared to healthy subjects (control group); samples were measured using ultrasensitive single-molecule arrays (Simoa®). Glomerular barrier function was assessed based on albumin-creatinine ratio (ACR); biomarker-creatinine ratios were calculated for correction of urine dilution. RESULTS: Ninety-three urine-serum pairs in the target group and 10 urine-serum pairs in the control group were measured. The mean absolute concentration ± standard deviation in urine of the target and control groups were 184.7 ± 362.4 pg/ml and 27.3 ± 24.1 pg/ml for GFAP (r = 0.3 [Wilcoxon effect size], p = 0.007), 17.5 ± 38.6 pg/ml and 0.9 ± 0.3 pg/ml for NfL (r = 0.4, p < 0.005), 320.2 ± 443.3 pg/ml and 109.6 ± 116.8 pg/ml for UCH-L1 (r = 0.26, p = 0.014), and 219.5 ± 255.8 pg/ml and 21.1 ± 27.1 pg/ml for t-tau (r = 0.37, p < 0.005), respectively, whereas biomarker-creatinine ratio was significantly different only for NfL (r = 0.29, p = 0.015) and t-tau (r = 0.32, p < 0.01). In patients with intact glomerular barrier (ACR < 30 mg/g), only NfL in urine was significantly different between the target and control group and showed a significant correlation with the respective serum concentrations (r = 0.58 [Pearson's correlation-coefficient], p < 0.005). CONCLUSION: All four investigated biomarkers could be measured in urine, with NfL and t-tau showing the strongest effect size after correction for urine dilution. NfL revealed the most accurate relation between serum and urine concentrations in patients with intact kidney function.


Assuntos
AVC Isquêmico , Humanos , Creatinina , Encéfalo/metabolismo , Neurônios , Biomarcadores , Proteína Glial Fibrilar Ácida , Proteínas de Neurofilamentos
2.
Clin Chem Lab Med ; 61(2): 302-310, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36395058

RESUMO

OBJECTIVES: During 2020, the UK's Department of Health and Social Care (DHSC) established the Moonshot programme to fund various diagnostic approaches for the detection of SARS-CoV-2, the pathogen behind the COVID-19 pandemic. Mass spectrometry was one of the technologies proposed to increase testing capacity. METHODS: Moonshot funded a multi-phase development programme, bringing together experts from academia, industry and the NHS to develop a state-of-the-art targeted protein assay utilising enrichment and liquid chromatography tandem mass spectrometry (LC-MS/MS) to capture and detect low levels of tryptic peptides derived from SARS-CoV-2 virus. The assay relies on detection of target peptides, ADETQALPQRK (ADE) and AYNVTQAFGR (AYN), derived from the nucleocapsid protein of SARS-CoV-2, measurement of which allowed the specific, sensitive, and robust detection of the virus from nasopharyngeal (NP) swabs. The diagnostic sensitivity and specificity of LC-MS/MS was compared with reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) via a prospective study. RESULTS: Analysis of NP swabs (n=361) with a median RT-qPCR quantification cycle (Cq) of 27 (range 16.7-39.1) demonstrated diagnostic sensitivity of 92.4% (87.4-95.5), specificity of 97.4% (94.0-98.9) and near total concordance with RT-qPCR (Cohen's Kappa 0.90). Excluding Cq>32 samples, sensitivity was 97.9% (94.1-99.3), specificity 97.4% (94.0-98.9) and Cohen's Kappa 0.95. CONCLUSIONS: This unique collaboration between academia, industry and the NHS enabled development, translation, and validation of a SARS-CoV-2 method in NP swabs to be achieved in 5 months. This pilot provides a model and pipeline for future accelerated development and implementation of LC-MS/MS protein/peptide assays into the routine clinical laboratory.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Pandemias , COVID-19/diagnóstico , Teste para COVID-19 , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida , Estudos Prospectivos , Técnicas de Laboratório Clínico/métodos , Sensibilidade e Especificidade , Peptídeos
3.
Proteomics ; 22(13-14): e2100170, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35598103

RESUMO

Limited data exist on the performance of high-throughput proteomics profiling in epidemiological settings, including the impact of specimen collection and within-person variability over time. Thus, the Olink (972 proteins) and SOMAscan7Kv4.1 (7322 proteoforms of 6596 proteins) assays were utilized to measure protein concentrations in archived plasma samples from the Nurses' Health Studies and Health Professionals Follow-Up Study. Spearman's correlation coefficients (r) and intraclass correlation coefficients (ICCs) were used to assess agreement between (1) 42 triplicate samples processed immediately, 24-h or 48-h after blood collection from 14 participants; and (2) 80 plasma samples from 40 participants collected 1-year apart. When comparing samples processed immediately, 24-h, and 48-h later, 55% of assays had an ICC/r ≥ 0.75 and 87% had an ICC/r ≥ 0.40 in Olink compared to 44% with an ICC/r ≥ 0.75 and 72% with an ICC/r ≥ 0.40 in SOMAscan7K. For both platforms, >90% of the assays were stable (ICC/r ≥ 0.40) in samples collected 1-year apart. Among 817 proteins measured with both platforms, Spearman's correlations were high (r > 0.75) for 14.7% and poor (r < 0.40) for 44.8% of proteins. High-throughput proteomics profiling demonstrated reproducibility in archived plasma samples and stability after delayed processing in epidemiological studies, yet correlations between proteins measured with the Olink and SOMAscan7K platforms were highly variable.


Assuntos
Proteômica , Manejo de Espécimes , Estudos Epidemiológicos , Seguimentos , Humanos , Reprodutibilidade dos Testes
4.
J Clin Microbiol ; 60(6): e0007522, 2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35574677

RESUMO

Sensitive and specific serological tests are mandatory for epidemiological studies evaluating severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) prevalence as well as coronavirus disease 2019 (COVID-19) morbidity and mortality rates. The accuracy of results is challenged by antibody waning after convalescence and by cross-reactivity induced by previous infections with other pathogens. By employing a patented platform technology based on capturing antigen-antibody complexes with a solid-phase-bound Fcγ receptor (FcγR) and truncated nucleocapsid protein as the antigen, two SARS-CoV-2 IgG enzyme-linked immunosorbent assays (ELISAs), featuring different serum and antigen dilutions, were developed. Validation was performed using a serum panel comprising 213 longitudinal samples from 35 COVID-19 patients and a negative-control panel consisting of 790 pre-COVID-19 samples from different regions of the world. While both assays show similar diagnostic sensitivities in the early convalescent phase, ELISA 2 (featuring a higher serum concentration) enables SARS-CoV-2 IgG antibody detection for a significantly longer time postinfection (≥15 months). Correspondingly, analytical sensitivity referenced to indirect immunofluorescence testing (IIFT) is significantly higher for ELISA 2 in samples with a titer of ≤1:640; for high-titer samples, a prozone effect is observed for ELISA 2. The specificities of both ELISAs were excellent not only for pre-COVID-19 serum samples from Europe, Asia, and South America but also for several challenging African sample panels. The SARS-CoV-2 IgG FcγR ELISAs, methodically combining antigen-antibody binding in solution and isotype-specific detection of immune complexes, are valuable tools for seroprevalence studies requiring the (long-term) detection of anti-SARS-CoV-2 IgG antibodies in populations with a challenging immunological background and/or in which spike-protein-based vaccine programs have been rolled out.


Assuntos
COVID-19 , Receptores de IgG , Anticorpos Antivirais , COVID-19/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Imunoglobulina G , Proteínas do Nucleocapsídeo , SARS-CoV-2 , Sensibilidade e Especificidade , Estudos Soroepidemiológicos , Glicoproteína da Espícula de Coronavírus
5.
J Transl Med ; 20(1): 199, 2022 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-35538547

RESUMO

BACKGROUND: Urinary extracellular vesicles (EVs) are a source of biomarkers with broad potential applications across clinical research, including monitoring radiation exposure. A key limitation to their implementation is minimal standardization in EV isolation and analytical methods. Further, most urinary EV isolation protocols necessitate large volumes of sample. This study aimed to compare and optimize isolation and analytical methods for EVs from small volumes of urine. METHODS: 3 EV isolation methods were compared: ultracentrifugation, magnetic bead-based, and size-exclusion chromatography from 0.5 mL or 1 mL of rat and human urine. EV yield and mass spectrometry signals (Q-ToF and Triple Quad) were evaluated from each method. Metabolomic profiling was performed on EVs isolated from the urine of rats exposed to ionizing radiation 1-, 14-, 30- or 90-days post-exposure, and human urine from patients receiving thoracic radiotherapy for the treatment of lung cancer pre- and post-treatment. RESULTS: Size-exclusion chromatography is the preferred method for EV isolation from 0.5 mL of urine. Mass spectrometry-based metabolomic analyses of EV cargo identified biochemical changes induced by radiation, including altered nucleotide, folate, and lipid metabolism. We have provided standard operating procedures for implementation of these methods in other laboratories. CONCLUSIONS: We demonstrate that EVs can be isolated from small volumes of urine and analytically investigated for their biochemical contents to detect radiation induced metabolomic changes. These findings lay a groundwork for future development of methods to monitor response to radiotherapy and can be extended to an array of molecular phenotyping studies aimed at characterizing EV cargo.


Assuntos
Vesículas Extracelulares , Exposição à Radiação , Animais , Biomarcadores/metabolismo , Vesículas Extracelulares/metabolismo , Humanos , Espectrometria de Massas , Ratos , Ultracentrifugação
6.
Clin Chem ; 68(11): 1410-1424, 2022 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-36264679

RESUMO

BACKGROUND: Indirect methods leverage real-world data for the estimation of reference intervals. These constitute an active field of research, and several methods have been developed recently. So far, no standardized tool for evaluation and comparison of indirect methods exists. METHODS: We provide RIbench, a benchmarking suite for quantitative evaluation of any existing or novel indirect method. The benchmark contains simulated test sets for 10 biomarkers mimicking routine measurements of a mixed distribution of non-pathological (reference) values and pathological values. The non-pathological distributions represent 4 common distribution types: normal, skewed, heavily skewed, and skewed-and-shifted. To identify strengths and weaknesses of indirect methods, test sets have varying sample sizes and pathological distributions differ in location, extent of overlap, and fraction. For performance evaluation, we use an overall benchmark score and sub-scores derived from absolute z-score deviations between estimated and true reference limits. We illustrate the application of RIbench by evaluating and comparing the Hoffmann method and 4 modern indirect methods -TML (Truncated-Maximum-Likelihood), kosmic, TMC (Truncated-Minimum-Chi-Square), and refineR- against one another and against a nonparametric direct method (n = 120). RESULTS: For the modern indirect methods, pathological fraction and sample size had a strong influence on the results: With a pathological fraction up to 20% and a minimum sample size of 5000, most methods achieved results comparable or superior to the direct method. CONCLUSIONS: We present RIbench, an open-source R-package, for the systematic evaluation of existing and novel indirect methods. RIbench can serve as a tool for enhancement of indirect methods, improving the estimation of reference intervals.


Assuntos
Benchmarking , Humanos , Valores de Referência , Tamanho da Amostra
7.
Clin Chem ; 68(2): 291-302, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34897415

RESUMO

BACKGROUND: The European Society of Cardiology (ESC) rule-out algorithms use cutoffs optimized for exclusion of non-ST elevation myocardial infarction (NSTEMI). We investigated these and several novel algorithms for the rule-out of non-ST elevation acute coronary syndrome (NSTE-ACS) including less urgent coronary ischemia. METHOD: A total of 1504 unselected patients with suspected NSTE-ACS were included and divided into a derivation cohort (n = 988) and validation cohort (n = 516). The primary endpoint was the diagnostic performance to rule-out NSTEMI and unstable angina pectoris during index hospitalization. The secondary endpoint was combined MI, all-cause mortality (within 30 days) and urgent (24 h) revascularization. The ESC algorithms for high-sensitivity cardiac troponin T (hs-cTnT) and I (hs-cTnI) were compared to different novel low-baseline (limit of detection), low-delta (based on the assay analytical and biological variation), and 0-1-h and 0-3-h algorithms. RESULTS: The prevalence of NSTE-ACS was 24.8%, 60.0% had noncardiac chest pain, and 15.2% other diseases. The 0-1/0-3-h algorithms had superior clinical sensitivity for the primary endpoint compared to the ESC algorithm (validation cohort); hs-cTnT: 95% vs 63%, and hs-cTnI: 87% vs 64%, respectively. Regarding the secondary endpoint, the algorithms had similar clinical sensitivity (100% vs 94%-96%) but lower clinical specificity (41%-19%) compared to the ESC algorithms (77%-74%). The rule-out rates decreased by a factor of 2-4. CONCLUSION: Low concentration/low-delta troponin algorithms improve the clinical sensitivity for a combined endpoint of NSTEMI and unstable angina pectoris, with the cost of a substantial reduction in total rule-out rate. There was no clear benefit compared to ESC for diagnosing high-risk events.


Assuntos
Síndrome Coronariana Aguda , Infarto do Miocárdio , Infarto do Miocárdio sem Supradesnível do Segmento ST , Síndrome Coronariana Aguda/diagnóstico , Algoritmos , Angina Instável/diagnóstico , Biomarcadores , Humanos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Troponina I , Troponina T
8.
Clin Chem ; 68(8): 1075-1083, 2022 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-35699503

RESUMO

BACKGROUND: Newborn screening (NBS) laboratories in the United Kingdom adhere to common protocols based on single analyte cutoff values (COVs); therefore, interlaboratory harmonization is of paramount importance. Interlaboratory variation for screening analytes in UK NBS laboratories ranges from 17% to 59%. While using common stable isotope internal standards has been shown to significantly reduce interlaboratory variation, instrument set-up, sample extraction, and calibration approach are also key factors. METHODS: Dried blood spot (DBS) extraction processes, instrument set-up, mobile-phase composition, sample introduction technique, and calibration approach of flow injection analysis-tandem mass spectrometry (FIA-MS/MS) methods were optimized. Inter- and intralaboratory variation of methionine, leucine, phenylalanine, tyrosine, isovaleryl-carnitine, glutaryl-carnitine, octanoyl-carnitine, and decanoyl-carnitine were determined pre- and postoptimization, using 3 different calibration approaches. RESULTS: Optimal recovery of analytes from DBS was achieved with a 35-min extraction time and 80% methanol (150 µL). Optimized methodology decreased the mean intralaboratory percentage relative SD (%RSD) for the 8 analytes from 20.7% (range 4.1-46.0) to 5.4% (range 3.0-8.5). The alternative calibration approach reduced the mean interlaboratory %RSD for all analytes from 16.8% (range 4.1-25.0) to 7.1% (range 4.1-11.0). Nuclear magnetic resonance analysis of the calibration material highlighted the need for standardization. The purities of isovaleryl-carnitine and glutaryl-carnitine were 85.13% and 69.94% respectively, below the manufacturer's stated values of ≥98%. CONCLUSIONS: For NBS programs provided by multiple laboratories using single analyte COVs, harmonization and standardization of results can be achieved by optimizing legacy FIA-MS/MS methods, adopting a common analytical protocol, and using standardized calibration material rather than internal calibration.


Assuntos
Análise de Injeção de Fluxo , Espectrometria de Massas em Tandem , Calibragem , Carnitina , Análise de Injeção de Fluxo/métodos , Humanos , Recém-Nascido , Triagem Neonatal/métodos , Padrões de Referência , Espectrometria de Massas em Tandem/métodos
9.
Clin Chem Lab Med ; 60(5): 740-747, 2022 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-35150123

RESUMO

OBJECTIVES: Internal quality control (IQC) plays an important role in quality assurance in laboratory medicine. However, there is no universal consensus or guideline on when and how IQC should be analyzed on point-of-care testing (POCT) devices. The aim of this study was to develop a scoring system to determine how often IQC should be analyzed in primary healthcare on the various POCT devices. METHODS: Based on a systematic literature review and a thorough process involving the whole Noklus, a nationwide POC organization, a scoring system for when to analyze IQC was developed. Four factors were considered to significantly impact IQC frequency: The importance of the analyte in diagnosing and monitoring patients, type of POCT device, user-friendliness, and number of patient samples. For each POCT device, the first three factors were given a score, and the sum of the scores determined the general recommended IQC frequency. The number of patient samples determined whether and how to adjust these frequencies in each individual general practice. RESULTS: The scoring system was applied to 17 analytes and 134 different POCT devices (153 analyte-device combinations). Most of the devices analyzing high-risk analytes (71 out of 74) obtained daily or weekly IQC frequency. For example, all blood-cell counters and all glucose meters should undergo IQC daily and weekly, respectively. CONCLUSIONS: This study presents a consensus-based scoring system for differentiated and device-specific recommendations for IQC frequency on POCT devices in primary healthcare. The scoring system can easily be adopted to other local environments and is easy to use.


Assuntos
Laboratórios , Testes Imediatos , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Atenção Primária à Saúde , Controle de Qualidade
10.
Clin Chem ; 67(12): 1699-1708, 2021 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-34580703

RESUMO

BACKGROUND: Blood typing, donor compatibility testing, and hematocrit analysis are common tests that are important in many clinical applications, including those found in high-stakes settings such as the trauma center. These tests are typically performed in centralized laboratories with sample batching; the minutes that are lost in this mode can lead to adverse outcomes, especially for critical-care patients. As a step toward providing rapid results at the bedside, we developed a point-of-care hemagglutination system relying on digital microfluidics (DMF) and a unique, automated readout tool, droplet agglutination assessment using digital microfluidics (DAAD). METHODS: ABO and Rhesus blood grouping, donor crossmatching, and hematocrit assays were developed on a portable DMF platform that allowed for automated sample processing. The result of each assay could be determined by eye or automatically with the DAAD imaging tool. RESULTS: DMF-DAAD was applied to 109 samples collected from different sources (including commercial samples, pinpricks from volunteers, and a hospital blood bank), with perfect fidelity to gold-standard results. Some of these tests were carried out by a nonexpert in a hospital trauma center. Proof-of-concept results were also collected from smaller sample sets for donor compatibility testing and hematocrit analysis. CONCLUSION: DMF-DAAD shows promise for delivering rapid, reliable results in a format well suited for a trauma center and other settings where every minute counts.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas , Microfluídica , Bancos de Sangue , Hemaglutinação , Hematócrito , Humanos , Microfluídica/métodos
11.
Sex Transm Infect ; 97(6): 397-401, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33208510

RESUMO

OBJECTIVES: Biologically false positive (BFP) reactions are well described in early literature. However, only a few recent reports described the incidence and clinical characteristics of patients with BFP reactions. We reviewed the serological test results of patients tested for syphilis in our hospital in the past decade and described the clinical characteristics of patients with BFP reactions. METHODS: This is a retrospective study of patients tested for syphilis in a tertiary academic hospital. All serological results were retrieved from the clinical laboratory database. We calculated the incidence of BFP reactions. Clinical characteristics and laboratory data of patients with BFP reactions were reviewed manually. RESULTS: Among 94 462 subjects, 588 patients had BFP reactions (0.62%). Most BFP reactions were observed in patients aged over 60 years, with a history of malignancy and autoimmune diseases. Eighty-five per cent of patients had low rapid plasma reagin (RPR) titre (≤1:4), but two patients had extremely high RPR titre (≥1:256). BFP reactions were more likely to persist beyond 6 months among patients with RPR titre of ≥1:8. There was no statistically significant correlation between RPR titre and total protein albumin gap, surrogate of immunoglobulin levels among patients with BFP reactions. CONCLUSION: There was a low incidence of BFP reactions in the last decade. A minority of BFP reactions had high non-treponemal antibody titre and persisted longer than 6 months. In the era of re-emergence of syphilis, this information could help clinicians interpret the results of well-established diagnostic tests for syphilis.


Assuntos
Centros Médicos Acadêmicos/estatística & dados numéricos , Sífilis/epidemiologia , Centros de Atenção Terciária/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Reações Falso-Positivas , Feminino , Humanos , Lactente , Recém-Nascido , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Testes Sorológicos , Sífilis/imunologia , Sorodiagnóstico da Sífilis , Treponema pallidum/imunologia , Adulto Jovem
12.
Artigo em Inglês | MEDLINE | ID: mdl-33132676

RESUMO

Field analyzers for the measurement of lead in drinking water samples are gaining interest from states, water utilities and building managers as rapid, inexpensive and simple tools to quantify lead concentrations. This literature review compares data quality by field analyzers to established laboratory methods and provides practical information (e.g. costs, ease-of-use) on commercial lead analyzers that are based on: (1) Electrochemistry, (2) Colorimetry and (3) Fluorescence. Between and within these three general field analyzer categories, manufacturers specify a variety of protocols to prepare the samples, which differ from the standard acidification in laboratory methods. Review of the literature raised concerns that without adequate sample preparation, field analyzers may not always fully quantify the total lead concentration, including particulate lead, thereby resulting in underestimations. Nonetheless, field analyzers have been used to quickly obtain experimental results in the laboratory, or in the field when access to laboratory equipment was limited, expensive or otherwise impractical. Field analyzers were also successfully used to detect lead from service lines, by a water utility where lead was mostly in the dissolved form. Overall, intrinsic strengths and weaknesses of field analyzers are discussed, to better balance practical convenience and adequate data quality depending on the objective.

13.
Bratisl Lek Listy ; 121(12): 840-846, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33300351

RESUMO

BACKGROUND: The toxigenic strains of Clostridioides (Clostridium) difficile is the most common pathogen of nosocomial and antibiotic-related diarrhoea in healthcare facilities. Lately, there has been an increase in the incidence of C. difficile infection (CDI) cases in Slovakia. MATERIALS AND METHODS: Retrospective analysis of the CDI appearance was carried out in the Zilina region. Additionally, an electronic survey focused on the diagnosis and treatment management of C. difficile infection was conducted among leading clinicians of the wards where CDI was present. RESULTS: Eighty percent of clinicians reported that they were following the recommendations for diagnosis and treatment of C. difficile infection in their everyday practice. The majority of leading physicians were from internal medicine wards (50 %). Most respondents stated that the laboratory results correlated with the clinical symptoms of patients. The first-choice treatment of C. difficile infections was reported to be oral vancomycin (in 21.7 %) and oral metronidazole (in 47.8 %). The estimate of first-choice treatment success rate was 80 %, while the recurrence rate and severe course was observed in 20%. Vancomycin was the standard treatment for recurrent infection. It was administered orally either alone (31 %) or combined with metronidazole (38 %) or fidaxomicin (31 %). CONCLUSION: The results of the survey showed that recommendations for the diagnosis and treatment were implemented in the wards of hospitals and showed the awareness of the necessity of rapid diagnosis and early treatment of C. difficile infection in patients (Fig. 4, Ref. 30).


Assuntos
Infecções por Clostridium , Aminoglicosídeos , Antibacterianos/uso terapêutico , Clostridioides difficile , Infecções por Clostridium/diagnóstico , Infecções por Clostridium/tratamento farmacológico , Infecções por Clostridium/epidemiologia , Humanos , Estudos Retrospectivos , Eslováquia/epidemiologia , Inquéritos e Questionários
14.
Sex Transm Infect ; 95(1): 43-45, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30072393

RESUMO

OBJECTIVES: This is a comparative review between using dried blood spot (DBS) and mini-tube (MT) HIV sampling kits as part of an online sexually transmitted infection (STI) postal testing service. England has recently seen increases in internet-based and postal (eHealth) STI services. Expanding accessibility and testing for patients, cost implications and narrowing the HIV undiagnosed margin are drivers for this. METHODS: In 2017, data were reviewed from an online postal STI kit requesting service at a time of transitioning from MT to DBS. We compared the STI postal kit and HIV blood sample return rates, and the successful processing/analysis rates of the DBS and MT kits. Descriptive statistics were applied to participant characteristics, with Pearson's χ2 or Fisher exact test used to demonstrate statistical differences. We also describe and calculate a 'request-to-result ratio' (RRR) for both kit types. The RRR is defined as the number of online kit requests required to produce one successfully analysed result. RESULTS: 550 STI postal kit requests from a North-West of England region were reviewed from 13 June 2017 to 22 September 2017 (275 MT, 275 DBS). Baseline characteristics between the two groups were comparable (63% woman, 90% white British and 86% heterosexual with a median age of 26 years). The successful processing rate for the DBS was 98.8% c.f. 55.7% for the MT (p<0.001). The RRR for MT was 2.96, c.f. 1.70 for DBS. There was a 5.4% false positive HIV rate in the MT c.f. none in the DBS. CONCLUSIONS: This comparative analysis suggests that in this community setting, the use of postal HIV DBS kits resulted in a significantly improved RRR compared with MT. The biggest factor was the large number of MT samples not analysed due to inadequate blood volumes. The unexpected level of false positive results in the MT samples needs confirming in larger studies.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Infecções por HIV/diagnóstico , Serviços Postais , Telemedicina/métodos , Adulto , Análise Química do Sangue/métodos , Coleta de Amostras Sanguíneas/métodos , Inglaterra , Reações Falso-Positivas , Feminino , Anticorpos Anti-HIV/análise , Antígenos HIV/análise , Infecções por HIV/sangue , Heterossexualidade , Humanos , Masculino , Programas de Rastreamento , Testes Sorológicos , Minorias Sexuais e de Gênero , Adulto Jovem
15.
Medicina (Kaunas) ; 55(8)2019 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-31366156

RESUMO

BACKGROUND AND OBJECTIVES: Human papillomavirus (HPV) is the most prevalent etiological agent of viral sexually-transmitted infection. This study retrospectively evaluated the impact of a switch to a real-time PCR assay in the HPV prevalence and genotypes distribution by a quasi-experimental before-and-after approach. MATERIALS AND METHODS: In total, 1742 samples collected from 1433 patients were analyzed at the UOC Microbiology and Virology of Policlinico of Bari, Italy. HPV DNA detection was performed using initially nested PCR and subsequently multiplex real-time PCR assay. RESULTS: Statistically significant difference in HPV overall prevalence after the introduction of the real-time assay was not detected (48.97% vs. 50.62%). According to different extraction-DNA amplification methods, differences were observed in the prevalence rates of HPV-45, 68, 40, 42, and 43. The lowest prevalence for HPV-45 was observed in the Magna Pure-Real Time PCR group, while HPV-68, 40, 42, and 43 were less observed in the Qiagen-Real Time PCR group. After, a multivariate logistic regression, an increase in the prevalence of HPV-42 (aOR: 4.08, 95% CI: 1.71-9.73) was associated with the multiplex real-time PCR assay. CONCLUSIONS: Although this study is a not a direct comparison between two diagnostic methods because it has a sequential structure, it serves to verify the impact of a new molecular assay on HPV distribution. Moreover, the stability of HPV prevalence over time suggests that the population composition and the behavioral variables did not likely change during the observation period. Our study proposes that the introduction of a molecular test for HPV detection may be related to changes of HPV genotypes distribution.


Assuntos
Reação em Cadeia da Polimerase Multiplex/normas , Infecções por Papillomavirus/virologia , Reação em Cadeia da Polimerase/normas , Humanos , Itália , Reação em Cadeia da Polimerase Multiplex/métodos , Reação em Cadeia da Polimerase Multiplex/estatística & dados numéricos , Papillomaviridae/genética , Reação em Cadeia da Polimerase/métodos , Reação em Cadeia da Polimerase/estatística & dados numéricos , Prevalência , Estudos Retrospectivos
16.
Sud Med Ekspert ; 62(2): 55-60, 2019.
Artigo em Russo | MEDLINE | ID: mdl-31213594

RESUMO

The objective of the present work was the analysis of the literature publications concerned with the modern approaches to the diagnostics of gunshot injuries with special reference to the most promising applications of the immunohistochemical methods. The use of certain antibodies for determining of intravitality and prescription of gunshot injuries is illustrated by concrete examples. It is concluded that further studies on the possibilities for the application of the immunohistochemical methods are needed.


Assuntos
Imuno-Histoquímica , Ferimentos por Arma de Fogo/diagnóstico , Humanos
17.
J Clin Lab Anal ; 32(9): e22594, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29921038

RESUMO

BACKGROUND: Hydroelectrolytic disorders are common in clinical situations and may be harmful to the patient, especially those involving plasma sodium and potassium dosages. Among the possible methods for the dosages are flame photometry, ion-selective electrode (ISE) and colorimetric enzymatic method. METHODS: We analyzed 175 samples in the three different methods cited from patients attending the laboratory of the University Hospital of the Federal University of Juiz de Fora. The values obtained were statistically treated using SPSS 19.0 software. The present study aims to evaluate the impact of the use of these different methods in the determination of plasma sodium and potassium. RESULTS: The averages obtained for sodium and potassium measurements by flame photometry were similar (P > .05) to the means obtained for the two electrolytes by ISE. The averages obtained by the colorimetric enzymatic method presented statistical difference in relation to ISE, both for sodium and potassium. In the correlation analysis, both flame photometry and colorimetric enzymatic showed a strong correlation with the ISE method for both dosages. CONCLUSION: At the first time in the same work sodium and potassium were analyzed by three different methods and the results allowed us to conclude that the methods showed a positive and strong correlation, and can be applied in the clinical routine.


Assuntos
Colorimetria/métodos , Fotometria/métodos , Potássio/sangue , Sódio/sangue , Adolescente , Adulto , Idoso , Correlação de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Potássio/análise , Sódio/análise , Adulto Jovem
18.
Sud Med Ekspert ; 61(4): 59-62, 2018.
Artigo em Russo | MEDLINE | ID: mdl-30168532

RESUMO

This article was designed to consider the problem of diagnostics of prescription of death coming taking account of the present-day level of the forensic medical activities with special reference to the disadvantages of the application of the classical and laboratory diagnostic methods for the establishment of prescription of death coming. The priority approaches to addressing this problem are highlighted.


Assuntos
Autopsia/métodos , Morte , Patologia Legal/métodos , Humanos , Mudanças Depois da Morte , Fatores de Tempo
20.
Euro Surveill ; 22(45)2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29162204

RESUMO

Enteroviruses (EVs) cause severe outbreaks of respiratory and neurological disease as illustrated by EV-D68 and EV-A71 outbreaks, respectively. We have mapped European laboratory capacity for identification and characterisation of non-polio EVs to improve preparedness to respond to (re)-emerging EVs linked to severe disease. An online questionnaire on non-polio EV surveillance and laboratory detection was submitted to all 30 European Union (EU)/European Economic Area (EEA) countries. Twenty-nine countries responded; 26 conducted laboratory-based non-polio EV surveillance, and 24 included neurological infections in their surveillance. Eleven countries have established specific surveillance for EV-D68 via sentinel influenza surveillance (n = 7), typing EV-positive respiratory samples (n = 10) and/or acute flaccid paralysis surveillance (n = 5). Of 26 countries performing non-polio EV characterisation/typing, 10 further characterised culture-positive EV isolates, whereas the remainder typed PCR-positive but culture-negative samples. Although 19 countries have introduced sequence-based EV typing, seven still rely entirely on virus isolation. Based on 2015 data, six countries typed over 300 specimens mostly by sequencing, whereas 11 countries characterised under 50 EV-positive samples. EV surveillance activity varied between EU/EEA countries, and did not always specifically target patients with neurological and/or respiratory infections. Introduction of sequence-based typing methods is needed throughout the EU/EEA to enhance laboratory capacity for the detection of EVs.


Assuntos
Surtos de Doenças/prevenção & controle , Enterovirus Humano D/isolamento & purificação , Infecções por Enterovirus/diagnóstico , Enterovirus/isolamento & purificação , Infecções Respiratórias/virologia , Vigilância de Evento Sentinela , Adolescente , Proteínas do Capsídeo/genética , Criança , Notificação de Doenças , Enterovirus/genética , Enterovirus Humano D/genética , Infecções por Enterovirus/epidemiologia , Infecções por Enterovirus/virologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Infecções Respiratórias/epidemiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA