Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Neurosurg Focus ; 49(1): E5, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32610296

RESUMO

OBJECTIVE: Intracranial human brain recordings typically utilize recording systems that do not distinguish individual neuron action potentials. In such cases, individual neurons are not identified by location within functional circuits. In this paper, verified localization of singly recorded hippocampal neurons within the CA3 and CA1 cell fields is demonstrated. METHODS: Macro-micro depth electrodes were implanted in 23 human patients undergoing invasive monitoring for identification of epileptic seizure foci. Individual neurons were isolated and identified via extracellular action potential waveforms recorded via macro-micro depth electrodes localized within the hippocampus. A morphometric survey was performed using 3T MRI scans of hippocampi from the 23 implanted patients, as well as 46 normal (i.e., nonepileptic) patients and 26 patients with a history of epilepsy but no history of depth electrode placement, which provided average dimensions of the hippocampus along typical implantation tracks. Localization within CA3 and CA1 cell fields was tentatively assigned on the basis of recording electrode site, stereotactic positioning of the depth electrode in comparison with the morphometric survey, and postsurgical MRI. Cells were selected as candidate CA3 and CA1 principal neurons on the basis of waveform and firing rate characteristics and confirmed within the CA3-to-CA1 neural projection pathways via measures of functional connectivity. RESULTS: Cross-correlation analysis confirmed that nearly 80% of putative CA3-to-CA1 cell pairs exhibited positive correlations compatible with feed-forward connection between the cells, while only 2.6% exhibited feedback (inverse) connectivity. Even though synchronous and long-latency correlations were excluded, feed-forward correlation between CA3-CA1 pairs was identified in 1071 (26%) of 4070 total pairs, which favorably compares to reports of 20%-25% feed-forward CA3-CA1 correlation noted in published animal studies. CONCLUSIONS: This study demonstrates the ability to record neurons in vivo from specified regions and subfields of the human brain. As brain-machine interface and neural prosthetic research continues to expand, it is necessary to be able to identify recording and stimulation sites within neural circuits of interest.


Assuntos
Eletrofisiologia , Hipocampo/fisiologia , Vias Neurais/fisiologia , Neurônios/fisiologia , Estimulação Encefálica Profunda/métodos , Estimulação Elétrica/métodos , Eletrodos , Eletrofisiologia/métodos , Humanos
2.
Neurosurg Focus ; 48(2): E2, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32006952

RESUMO

OBJECTIVE: Stimulation of the primary somatosensory cortex (S1) has been successful in evoking artificial somatosensation in both humans and animals, but much is unknown about the optimal stimulation parameters needed to generate robust percepts of somatosensation. In this study, the authors investigated frequency as an adjustable stimulation parameter for artificial somatosensation in a closed-loop brain-computer interface (BCI) system. METHODS: Three epilepsy patients with subdural mini-electrocorticography grids over the hand area of S1 were asked to compare the percepts elicited with different stimulation frequencies. Amplitude, pulse width, and duration were held constant across all trials. In each trial, subjects experienced 2 stimuli and reported which they thought was given at a higher stimulation frequency. Two paradigms were used: first, 50 versus 100 Hz to establish the utility of comparing frequencies, and then 2, 5, 10, 20, 50, or 100 Hz were pseudorandomly compared. RESULTS: As the magnitude of the stimulation frequency was increased, subjects described percepts that were "more intense" or "faster." Cumulatively, the participants achieved 98.0% accuracy when comparing stimulation at 50 and 100 Hz. In the second paradigm, the corresponding overall accuracy was 73.3%. If both tested frequencies were less than or equal to 10 Hz, accuracy was 41.7% and increased to 79.4% when one frequency was greater than 10 Hz (p = 0.01). When both stimulation frequencies were 20 Hz or less, accuracy was 40.7% compared with 91.7% when one frequency was greater than 20 Hz (p < 0.001). Accuracy was 85% in trials in which 50 Hz was the higher stimulation frequency. Therefore, the lower limit of detection occurred at 20 Hz, and accuracy decreased significantly when lower frequencies were tested. In trials testing 10 Hz versus 20 Hz, accuracy was 16.7% compared with 85.7% in trials testing 20 Hz versus 50 Hz (p < 0.05). Accuracy was greater than chance at frequency differences greater than or equal to 30 Hz. CONCLUSIONS: Frequencies greater than 20 Hz may be used as an adjustable parameter to elicit distinguishable percepts. These findings may be useful in informing the settings and the degrees of freedom achievable in future BCI systems.


Assuntos
Interfaces Cérebro-Computador/normas , Epilepsia Resistente a Medicamentos/fisiopatologia , Eletrocorticografia/métodos , Eletrodos Implantados/normas , Desempenho Psicomotor/fisiologia , Córtex Somatossensorial/fisiologia , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Estimulação Elétrica/métodos , Eletrocorticografia/instrumentação , Humanos , Imageamento por Ressonância Magnética/métodos , Distribuição Aleatória , Tomografia Computadorizada por Raios X/métodos
3.
Neurosurg Focus ; 48(1): E10, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31896084

RESUMO

Pediatric brain tumors are the most common solid tumor and the first cause of cancer death in childhood, adolescence, and young adulthood. Current treatments are far from optimal in most of these tumors and the prognosis remains dismal for many of them. One of the main causes of the failure of current medical treatments is in part due to the existence of the blood-brain barrier (BBB), which limits drug delivery to tumors. Opening of the BBB with low-intensity pulsed ultrasound (LIPU) has emerged during the last 2 decades as a promising technique for enhancing drug delivery to the brain. In preclinical models, enhanced delivery of a wide range of therapeutic agents, from low-molecular-weight drugs, to antibodies and immune cells, has been observed as well as tumor control and increased survival. This technique has recently entered clinical trials with extracranial and intracranial devices. The safety and feasibility of this technique has furthermore been shown in patients treated monthly for recurrent glioblastoma receiving carboplatin chemotherapy. In this review, the characteristics of the BBB in the most common pediatric brain tumors are reviewed. Then, principles and mechanisms of BBB disruption with ultrasound (US) are summarized and described at the histological and biological levels. Lastly, preclinical studies that have used US-induced BBB opening in tumor models, recent clinical trials, and the potential use of this technology in pediatrics are provided.


Assuntos
Barreira Hematoencefálica/patologia , Neoplasias Encefálicas/tratamento farmacológico , Recidiva Local de Neoplasia/tratamento farmacológico , Ondas Ultrassônicas , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/patologia , Glioma/diagnóstico , Glioma/tratamento farmacológico , Glioma/patologia , Humanos , Recidiva Local de Neoplasia/diagnóstico , Recidiva Local de Neoplasia/patologia , Pediatria
4.
J Neurosurg ; : 1-8, 2019 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-31299656

RESUMO

OBJECTIVE: To develop and assess a convective delivery technique that enhances the effectiveness of drug delivery to nonspherical brain nuclei, the authors developed an occipital "infuse-as-you-go" approach to the putamen and compared it to the currently used transfrontal approach. METHODS: Eleven nonhuman primates received a bilateral putamen injection of adeno-associated virus with 2 mM gadolinium-DTPA by real-time MR-guided convective perfusion via either a transfrontal (n = 5) or occipital infuse-as-you-go (n = 6) approach. RESULTS: MRI provided contemporaneous assessment and monitoring of putaminal infusions for transfrontal (2 to 3 infusion deposits) and occipital infuse-as-you-go (stepwise infusions) putaminal approaches. The infuse-as-you-go technique was more efficient than the transfrontal approach (mean 35 ± 1.1 vs 88 ± 8.3 minutes [SEM; p < 0.001]). More effective perfusion of the postcommissural and total putamen was achieved with the infuse-as-you-go versus transfronatal approaches (100-µl infusion volumes; mean posterior commissural coverage 76.2% ± 5.0% vs 32.8% ± 2.9% [p < 0.001]; and mean total coverage 53.5% ± 3.0% vs 38.9% ± 2.3% [p < 0.01]). CONCLUSIONS: The infuse-as-you-go approach, paralleling the longitudinal axis of the target structure, provides a more effective and efficient method for convective infusate coverage of elongated, irregularly shaped subcortical brain nuclei.

5.
J Neurosurg ; : 1-8, 2019 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-31323637

RESUMO

OBJECTIVE: Botulinum toxin serotype A (BoNT/A) was reported to raise the seizure threshold when injected into the seizure focus of a kindled rodent model. Delivering BoNT/A to the nonhuman primate (NHP) central nervous system via convection-enhanced delivery (CED) has not been performed. The objective of this study was to determine the toxicity and distribution characteristics of CED of BoNT/A into the NHP hippocampus and cisterna magna. METHODS: Escalating BoNT/A doses were delivered by CED into the NHP hippocampus (n = 4) and cisterna magna (n = 5) for behavioral and histological assessment and to determine the highest nonlethal dose (LD0) and median lethal dose (LD50). Hippocampal BoNT/A was coinfused with Gd-albumin, a surrogate MRI tracer. Gd-albumin and radioiodinated BoNT/A (125I-BoNT/A) were coinfused into the hippocampus of 3 additional NHPs to determine BoNT/A distribution by in vivo MRI and postmortem quantitative autoradiography. Scintillation counting of CSF assessed the flow of 125I-BoNT/A from the hippocampus to CSF postinfusion. RESULTS: LD0 and LD50 were 4.2 and 18 ng/kg, and 5 and > 5 ng/kg for the NHP hippocampus and cisterna magna, respectively. Gd-albumin and 125I-BoNT/A completely perfused the hippocampus (155-234 mm3) in 4 of 7 NHPs. Fifteen percent of BoNT/A entered CSF after hippocampal infusion. The MRI distribution volume of coinfused Gd-albumin (VdMRI) was similar to the quantitative autoradiography distribution of 125I-BoNT/A (VdQAR) (mean VdMRI = 139.5 mm3 [n = 7]; VdQAR = 134.8 mm3 [n = 3]; r = 1.00, p < 0.0001). No infusion-related toxicity was identified histologically except that directly attributable to needle placement. CONCLUSIONS: Gd-albumin accurately tracked BoNT/A distribution on MRI. BoNT/A did not produce CNS toxicity. BoNT/A LD0 exceeded 10-fold the dose administered safely to humans for cosmesis and dystonia.

6.
J Neurosurg ; 132(2): 595-604, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30771782

RESUMO

OBJECTIVE: Successful convection-enhanced delivery of therapeutic agents to subcortical brain structures requires accurate cannula placement. Stereotactic guiding devices have been developed to accurately target brain nuclei. However, technologies remain limited by a lack of MRI compatibility, or by devices' size, making them suboptimal for direct gene delivery to brain parenchyma. The goal of this study was to validate the accuracy of a novel frameless skull-mounted ball-joint guide array (BJGA) in targeting the nonhuman primate (NHP) brain. METHODS: Fifteen MRI-guided cannula insertions were performed on 9 NHPs, each targeting the putamen. Optimal trajectories were planned on a standard MRI console using 3D multiplanar baseline images. After cannula insertion, the intended trajectory was compared to the final trajectory to assess deviation (euclidean error) of the cannula tip. RESULTS: The average cannula tip deviation was 1.18 ± 0.60 mm (mean ± SD) as measured by 2 independent reviewers. Topological analysis showed a superior, posterior, and rightward directional bias, and the intra- and interclass correlation coefficients were > 0.85, indicating valid and reliable intra- and interobserver evaluation. CONCLUSIONS: The data demonstrate that the BJGA can be used to reliably target subcortical brain structures by using MRI guidance, with accuracy comparable to current frameless stereotactic systems. The size and versatility of the BJGA, combined with a streamlined workflow, allows for its potential applicability to a variety of intracranial neurosurgical procedures, and for greater flexibility in executing MRI-guided experiments within the NHP brain.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neuronavegação/métodos , Procedimentos Neurocirúrgicos/métodos , Crânio/diagnóstico por imagem , Crânio/cirurgia , Animais , Encéfalo/diagnóstico por imagem , Encéfalo/cirurgia , Macaca mulatta , Imageamento por Ressonância Magnética/instrumentação , Masculino , Neuronavegação/instrumentação , Procedimentos Neurocirúrgicos/instrumentação , Técnicas Estereotáxicas/instrumentação
7.
J Neurosurg ; 125(2): 472-80, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26745490

RESUMO

OBJECTIVE Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a well-established therapy for motor symptoms in patients with pharmacoresistant Parkinson's disease (PD). However, the procedure, which requires multimodal perioperative exploration such as imaging, electrophysiology, or clinical examination during macrostimulation to secure lead positioning, remains challenging because the STN cannot be reliably visualized using the gold standard, T2-weighted imaging (T2WI) at 1.5 T. Thus, there is a need to improve imaging tools to better visualize the STN, optimize DBS lead implantation, and enlarge DBS diffusion. METHODS Gradient-echo sequences such as those used in T2WI suffer from higher distortions at higher magnetic fields than spin-echo sequences. First, a spin-echo 3D SPACE (sampling perfection with application-optimized contrasts using different flip angle evolutions) FLAIR sequence at 3 T was designed, validated histologically in 2 nonhuman primates, and applied to 10 patients with PD; their data were clinically compared in a double-blind manner with those of a control group of 10 other patients with PD in whom STN targeting was performed using T2WI. RESULTS Overlap between the nonhuman primate STNs segmented on 3D-histological and on 3D-SPACE-FLAIR volumes was high for the 3 most anterior quarters (mean [± SD] Dice scores 0.73 ± 0.11, 0.74 ± 0.06, and 0.60 ± 0.09). STN limits determined by the 3D-SPACE-FLAIR sequence were more consistent with electrophysiological edges than those determined by T2WI (0.9 vs 1.4 mm, respectively). The imaging contrast of the STN on the 3D-SPACE-FLAIR sequence was 4 times higher (p < 0.05). Improvement in the Unified Parkinson's Disease Rating Scale Part III score (off medication, on stimulation) 12 months after the operation was higher for patients who underwent 3D-SPACE-FLAIR-guided implantation than for those in whom T2WI was used (62.2% vs 43.6%, respectively; p < 0.05). The total electrical energy delivered decreased by 36.3% with the 3D-SPACE-FLAIR sequence (p < 0.05). CONCLUSIONS 3D-SPACE-FLAIR sequences at 3 T improved STN lead placement under stereotactic conditions, improved the clinical outcome of patients with PD, and increased the benefit/risk ratio of STN-DBS surgery.


Assuntos
Estimulação Encefálica Profunda/métodos , Imageamento por Ressonância Magnética , Doença de Parkinson/terapia , Núcleo Subtalâmico , Animais , Método Duplo-Cego , Eletrodos Implantados , Humanos , Imageamento Tridimensional , Macaca mulatta , Estudos Prospectivos
8.
J Neurosurg ; 123(6): 1569-77, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25932605

RESUMO

OBJECT: Assessing the safety and feasibility of chronic delivery of compounds to the brain using convection-enhanced delivery (CED) is important for the further development of this important therapeutic technology. The objective of this study was to follow and model the distribution of a compound delivered by CED into the putamen of rhesus monkeys. METHODS: The authors sequentially implanted catheters into 4 sites spanning the left and right putamen in each of 6 rhesus monkeys. The catheters were connected to implanted pumps, which were programmed to deliver a 5-mM solution of the MRI contrast agent Gd-DTPA at 0.1 µl/minute for 7 days and 0.3 µl/minute for an additional 7 days. The animals were followed for 28 days per implant cycle during which they were periodically examined with MRI. RESULTS: All animals survived the 4 surgeries with no deficits in behavior. Compared with acute infusion, the volume of distribution (Vd) increased 2-fold with 7 days of chronic infusion. Increasing the flow rate 3-fold over the next week increased the Vd an additional 3-fold. Following withdrawal of the compound, the half-life of Gd-DTPA in the brain was estimated as 3.1 days based on first-order pharmacokinetics. Histological assessment of the brain showed minimal tissue damage limited to the insertion site. CONCLUSIONS: These results demonstrate several important features in the development of a chronically implanted pump and catheter system: 1) the ability to place catheters accurately in a predetermined target; 2) the ability to deliver compounds in a chronic fashion to the putamen; and 3) the use of MRI and MR visible tracers to follow the evolution of the infusion volume over time.


Assuntos
Meios de Contraste/administração & dosagem , Convecção , Sistemas de Liberação de Medicamentos , Gadolínio DTPA/administração & dosagem , Bombas de Infusão Implantáveis , Putamen/metabolismo , Animais , Meios de Contraste/farmacocinética , Feminino , Gadolínio DTPA/farmacocinética , Macaca mulatta , Imageamento por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA