Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.264
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Magn Reson Med ; 91(6): 2638-2651, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38263948

RESUMO

PURPOSE: Our aim was to design and build a 3T 31P/1H calf coil that is capable of providing both good 31P and 1H transmit and receive performance, as well as being capable of accommodating a near-infrared spectroscopy (NIRS) device for simultaneous NIRS data and MRI/MRS acquisition. METHOD: In this work, we propose a new 3T 31P/1H birdcage combination design consisting of two co-centrically positioned birdcages on the same surface to maximize transmit efficiency and sensitivity for both nuclei. The 31P birdcage is a high-pass birdcage, whereas the 1H birdcage is a low-pass one to minimize coupling. The diameter of the 31P/1H birdcage combination was designed to be large enough to accommodate a NIRS device for simultaneous NIRS data and MRI/MRS acquisition. RESULTS: The one-layer coil structure of the birdcage combination significantly streamlines the mechanical design and coil assembly process. Full-wave simulation results show that the 31P and 1H are very well decoupled with each other, and the 1H and 31P SNR surpasses that of their standalone counterparts in the central area. Experiment results show that the inclusion of a NIRS device does not significantly affect the performance of the coil, thus enabling simultaneous NIRS and MRI readouts during exercise. CONCLUSION: Our findings demonstrate the feasibility and effectiveness of this dual-tuned coil design for combined NIRS and MRS measurements, offering potential benefits for studying metabolic and functional changes in the skeletal muscle in vivo.


Assuntos
Imageamento por Ressonância Magnética , Espectroscopia de Luz Próxima ao Infravermelho , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/diagnóstico por imagem , Simulação por Computador , Exercício Físico , Desenho de Equipamento , Imagens de Fantasmas
2.
Behav Brain Funct ; 20(1): 4, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38468270

RESUMO

BACKGROUND: Visual-motor integration (VMI) is an essential skill in daily life. The present study aimed to use functional near-infrared spectroscopy (fNIRS) technology to explore the effective connectivity (EC) changes among brain regions during VMI activities of varying difficulty levels. METHODS: A total of 17 healthy participants were recruited for the study. Continuous Performance Test (CPT), Behavior Rating Inventory of Executive Function-Adult Version (BRIEF-A), and Beery VMI test were used to evaluate attention performance, executive function, and VMI performance. Granger causality analysis was performed for the VMI task data to obtain the EC matrix for all participants. One-way ANOVA analysis was used to identify VMI load-dependent EC values among different task difficulty levels from brain network and channel perspectives, and partial correlation analysis was used to explore the relationship between VMI load-dependent EC values and behavioral performance. RESULTS: We found that the EC values of dorsal attention network (DAN) → default mode network (DMN), DAN → ventral attention network (VAN), DAN → frontoparietal network (FPN), and DAN → somatomotor network (SMN) in the complex condition were higher than those in the simple and moderate conditions. Further channel analyses indicated that the EC values of the right superior parietal lobule (SPL) → right superior frontal gyrus (SFG), right middle occipital gyrus (MOG) → left SFG, and right MOG → right postcentral gyrus (PCG) in the complex condition were higher than those in the simple and moderate conditions. Subsequent partial correlation analysis revealed that the EC values from DAN to DMN, VAN, and SMN were positively correlated with executive function and VMI performance. Furthermore, the EC values of right MOG → left SFG and right MOG → right PCG were positively correlated with attention performance. CONCLUSIONS: The DAN is actively involved during the VMI task and thus may play a critical role in VMI processes, in which two key brain regions (right SPL, right MOG) may contribute to the EC changes in response to increasing VMI load. Meanwhile, bilateral SFG and right PCG may also be closely related to the VMI performance.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Adulto , Humanos , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Função Executiva , Lobo Parietal
3.
Eur J Pediatr ; 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39110215

RESUMO

Preterm birth represents a public health problem, with prematurity being the leading cause of infant mortality. An objective brain maturation and oxygenation measurement are necessary. The objective has been To test the feasibility of EEG and NIRS combination in the assessment of physiological brain maturation and oxygenation in preterm and non-preterm babies. A systematic review in Pubmed, Web of Science, MEDLINE, Cochrane, Dialnet, CINAHL, Scopus, Lilacs and PEDro databases until December 2022 was developed. 598 registers were found, finally 5 of them reached the inclusion criteria. Two independent reviewers analyzed data and a third reviewer were available for discrepancies. All articles combined EEG and NIRS to assess brain oxygenation and maturation in healthy new-born babies. There is an agreement on the electrode's placement for EEG at P3 and P4; besides, these regions have been shown to be a development predictive area, as well as the frontoparietal region for the NIRS region and comparison between regions. There is little evidence about the physiological brain electrical activity and oxygenation without stimuli.Conclusion: EEG and NIRS have been useful to assess brain electrical activity and oxygenation in preterm and non-preterm. The combined measurement of these instruments could be essential in neurological disorders diagnosis or their sequels. Unfortunately, the heterogeneity of the results found prevents a consensus on which variables are the most appropriate for the assessment of this population. What is Known • Brain assessment could help clinicians to prevent sequels. • There is an agreement for EEG electrodes placement at P3 and P4 region. What is New • EEG and NIRS assessment are effective measurements for preterm babies. • P3 and P4 regions have shown to be a predictive area of development, as well as the frontoparietal region for NIRS assessment.

4.
Eur J Pediatr ; 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39136757

RESUMO

New health technologies are constantly developing. However, their impacts on health and implications for health systems are not always clear. Faced with this situation, in the last 45 years, Health Technology Assessment (HTA) has taken an important role in the decision-making process related to the implementation of technologies in healthcare systems. According to the Core Model® EUnetHTA, a "full HTA" should cover nine domains: health problems and current use of technology, description and technical characteristics, safety, clinical effectiveness, costs and economic evaluation, ethical analysis, organizational aspects, patients and social aspects, legal aspects. In all domains of a HTA, the approach is evidence-based and uses epidemiological data, systematic reviews to gather the best level of proofs regarding clinical efficacy and safety of interventions and comparators and organizational and economic models. One exception is the ethical analysis, that uses value-based approach. Although in Neonatal Intensive Care Units (NICUs) there are highly advanced technological environments, HTA has not yet been widely used in this field for determining the "value" of the diagnostic and therapeutic procedures. An example of diagnostic tool used in NICUs is the near-infrared spectroscopy (NIRS), a noninvasive device that enables real-time monitoring of the condition of peripheral tissues in critically ill newborns. The availability of this diagnostic tool could improve the choice of the most appropriate treatment to the clinical situation of the newborn. The expected benefit of NIRS motivates the need of a full HTA. Conclusion: HTA is still little used in Neonatal Critical Care, but it may be the appropriate tool to determine the "value" of technologies used in this field. The implementation of clinical trials and HTA may help in an evidence-based evaluation of new technologies for the neonatal critical care. This could facilitate the rapid introduction of the best health technologies into clinical practice. What is Known: • Health Technology Assessment (HTA) has taken an important role in the decision-making process related to the implementation of technologies in healthcare systems • The centrality of ethics in HTA has been known. In fact, ethics is everywhere in HTA, and value judgments permeate all levels of HTA What is New: • HTA is still little used in Neonatal Critical Care, but it may be the appropriate tool to determine the "value" of technologies used in this field • The implementation of clinical trials and HTA may help in an evidence-based evaluation of new technologies for the neonatal critical care and in introduction of the best and ethically acceptable health technologies into clinical practice.

5.
J Thromb Thrombolysis ; 57(3): 466-472, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38085469

RESUMO

Revascularization treatments (IV thrombolysis, mechanical thrombectomy) related to ischemic stroke have developed in recent years. With devices such as NIRS, non-invasive monitoring of treatment efficacy is provided. In this study, we aimed to use near-infrared spectroscopy (NIRS) as an objective monitoring method to see the effect of intravenous (IV) thrombolysis or mechanical thrombectomy treatments applied for cerebral oxygenation in patients with acute ischemic stroke. This study was carried out as a prospective study involving patients admitted to the emergency department in the years 2021-2022. NIRS measured regional oxygen saturation (rSO2) of both hemispheres of the brain before IV thrombolysis treatment, during the treatment at 0. min, 15. min, 30. min, 45. min, 60. min, after the treatment, and before and after the mechanical thrombectomy procedure. The significance level of the change in rSO2 values measured by NIRS was examined. 80 patients were included in the study. IV thrombolysis was applied to 58 patients, mechanical thrombectomy was applied to 5 of them, and both treatments were applied to 17 of them. In patients receiving IV thrombolysis, a significant difference was found in the affected hemisphere between the NIRS values measured at 0.min-15.min, 0.min-30.min, 0.min-45.min, 0.min-60.min, 0.min-post-treatment, 15.min-60.min (p < 0.001). In the patients included in the study, there was a strong and significant negative correlation between the deltaNIHSS value and the deltaNIRS values in the affected hemisphere (r=- 0.307, p = 0.013). There was a significant increase in the NIRS measurement values during and after the IV thrombolysis treatment in the affected hemisphere in the group with clinical improvement (p < 0.001). It is thought that IV thrombolysis or mechanical thrombectomy treatment applied to patients admitted to the emergency department with acute ischemic stroke can be followed objectively by NIRS.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Trombólise Mecânica , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/induzido quimicamente , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/tratamento farmacológico , AVC Isquêmico/etiologia , Espectroscopia de Luz Próxima ao Infravermelho , Estudos Prospectivos , Seguimentos , Trombectomia/métodos , Terapia Trombolítica/métodos , Resultado do Tratamento , Serviço Hospitalar de Emergência , Fibrinolíticos
6.
Artif Organs ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38884389

RESUMO

BACKGROUND: Functional electrical stimulation (FES) cycling has been reported to enhance muscle strength and improve muscle fatigue resistance after spinal cord injury (SCI). Despite its proposed benefits, the quantification of muscle fatigue during FES cycling remains poorly documented. This study sought to quantify the relationship between the vibrational performance of electrically-evoked muscles measured through mechanomyography (MMG) and its oxidative metabolism through near-infrared spectroscopy (NIRS) characteristics during FES cycling in fatiguing paralyzed muscles in individuals with SCI. METHODS: Six individuals with SCI participated in the study. They performed 30 min of FES cycling with MMG and NIRS sensors on their quadriceps throughout the cycling, and the signals were analyzed. RESULTS: A moderate negative correlation was found between MMG root mean square (RMS) and oxyhaemoglobin (O2Hb) [r = -0.38, p = 0.003], and between MMG RMS and total hemoglobin (tHb) saturation [r = -0.31, p = 0.017]. Statistically significant differences in MMG RMS, O2Hb, and tHb saturation occurred during pre- and post-fatigue of FES cycling (p < 0.05). CONCLUSIONS: MMG RMS was negatively associated with O2Hb and muscle oxygen derived from NIRS. MMG and NIRS sensors showed good inter-correlations, suggesting a promising use of MMG for characterizing metabolic fatigue at the muscle oxygenation level during FES cycling in individuals with SCI.

7.
Eur J Appl Physiol ; 124(2): 595-606, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37656280

RESUMO

PURPOSE: The physiological examination of boxing has been limited to systemic response in amateur athletes. The demands of professional boxing have been overlooked, despite the different competition format. We sought to determine the physiological demands placed on skeletal muscle in professional boxing. METHODS: Ten male professional boxers (age 26 ± 5 years, height 177 ± 4 cm, weight 71 ± 6 kg) were recruited for this observational study. On different days, the athletes completed 6 × 3 min rounds of pad, bag or spar-based training with 1 min recovery between each round. Prior to each session, participants put on a heart rate monitor and near-infrared spectroscopy attached to the belly of the rectus femoris muscle to record heart rate and muscle oxygenation. RESULTS: There were significantly less punches thrown in sparring compared to other training modalities (p < 0.001). Skeletal muscle oxygenation across training modalities consisted of a delay, fast desaturation and steady state. Across rounds there was a significant increase in time delay for desaturation (p = 0.016), rate of fast desaturation (p < 0.001) and duration of fast desaturation (p = 0.019). There was a significant difference in sparring for the heart rate where skeletal muscle oxygenation changes occurred compared to pads or bag sessions (p < 0.001). CONCLUSION: The findings highlight differences in the skeletal muscle response to the different training modalities. Practitioners need to be aware of the muscular demands of each session to allow optimal adaptation across a training camp. Training needs to allow the skeletal muscle to achieve a new oxygenation steady state rapidly to promote efficient performance across rounds.


Assuntos
Boxe , Humanos , Masculino , Adulto Jovem , Adulto , Boxe/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho , Fenômenos Fisiológicos Respiratórios , Músculo Esquelético , Músculo Quadríceps
8.
Eur J Appl Physiol ; 124(7): 2069-2079, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38400931

RESUMO

PURPOSE: Different strategies for near-infrared spectroscopy (NIRS)-derived muscle oxidative capacity assessment have been reported. This study compared and evaluated (I) approaches for averaging trials; (II) NIRS signals and blood volume correction equations; (III) the assessment of vastus lateralis (VL) and tibialis anterior (TA) muscles in two fitness levels groups. METHODS: Thirty-six participants [18 chronically trained (CT: 14 males, 4 females) and 18 untrained (UT: 10 males, 8 females)] participated in this study. Two trials of twenty transient arterial occlusions were performed for NIRS-derived muscle oxidative capacity assessment. Muscle oxygen consumption ( V ˙ O2m) was estimated from deoxygenated hemoglobin (HHb), corrected for blood volume changes following Ryan (HHbR) and Beever (HHbB) equations, and from oxygen saturation (StO2) in VL and TA. RESULTS: Superimposing or averaging V ˙ O2m or averaging the rate constants (k) from the two trials resulted in equivalent k values [two one-sided tests (TOST) procedure with 5% equivalence margin-P < 0.001]. Whereas HHbR (2.35 ± 0.61 min-1) and HHbB (2.34 ± 0.58 min-1) derived k were equivalent (P < 0.001), StO2 derived k (2.81 ± 0.92 min-1) was greater (P < 0.001) than both. k values were greater in CT vs UT in both muscles (VL: + 0.68 min-1, P = 0.002; TA: + 0.43 min-1, P = 0.01). CONCLUSION: Different approaches for averaging trials lead to similar k. HHb and StO2 signals provided different k, although different blood volume corrections did not impact k. Group differences in k were detected in both muscles.


Assuntos
Músculo Esquelético , Consumo de Oxigênio , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Masculino , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Consumo de Oxigênio/fisiologia , Feminino , Músculo Esquelético/metabolismo , Músculo Esquelético/fisiologia , Adulto , Oxigênio/metabolismo , Oxigênio/sangue , Hemoglobinas/metabolismo
9.
Eur J Appl Physiol ; 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38668851

RESUMO

PURPOSE: The critical force (CF) concept, differentiating steady and non-steady state conditions, extends the critical power paradigm for sport climbing. This study aimed to validate CF for finger flexors derived from the 4 min all-out test as a boundary for the highest sustainable work intensity in sport climbers. METHODS: Twelve participants underwent multiple laboratory visits. Initially, they performed the 4 min intermittent contraction all-out test for CF determination. Subsequent verification visits involved finger-flexor contractions at various intensities, including CF, CF -2 kg, CF -4 kg, and CF -6 kg, lasting for 720 s or until failure, while monitoring muscle-oxygen dynamics of forearm muscles. RESULTS: CF, determined from the mean force of last three contractions, was measured at 20.1 ± 5.7 kg, while the end-force at 16.8 ± 5.2 kg. In the verification trials, the mean time to failure at CF was 440 ± 140 s, with only one participant completing the 720 s task. When the load was continuously lowered (-2 kg, -4 kg, and -6 kg), a greater number of participants (38%, 69%, and 92%, respectively) successfully completed the 720 s task. Changes of muscle-oxygen dynamics showed a high variability and could not clearly distinguish between exhaustive and non-exhaustive trials. CONCLUSIONS: CF, based on the mean force of the last three contractions, failed to reliably predict the highest sustainable work rate. In contrast, determining CF as the end-force of the last three contractions exhibited a stronger link to sustainable work. Caution is advised in interpreting forearm muscle-oxygen dynamics, lacking sensitivity for nuanced metabolic responses during climbing-related tasks.

10.
Acta Paediatr ; 113(4): 700-708, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38156367

RESUMO

AIM: To investigate the effects of caffeine loading/maintenance administration on near-infrared spectroscopy cerebral, kidney and splanchnic patterns in preterm infants. METHODS: We conducted a multicentre case-control prospective study in 40 preterm infants (gestational age 29 ± 2 weeks) where each case acted as its own control. A caffeine loading dose of 20 mg/kg and a maintenance dose of 5 mg/kg after 24 h were administered intravenously. Near infrared spectroscopy monitoring parameters were monitored 30 min before, 30 min during and 180 min after caffeine therapy administration. RESULTS: A significant increase (p < 0.05) in splanchnic regional oxygenation and tissue function and a decrease (p < 0.05) in cerebral tissue function after loading dose was shown. A preferential hemodynamic redistribution from cerebral to splanchnic bloodstream was also observed. After caffeine maintenance dose regional oxygenation did not change in the monitored districts, while tissue function increased in kidney and splanchnic bloodstream. CONCLUSION: Different caffeine administration modalities affect cerebral/systemic oxygenation status, tissue function and hemodynamic pattern in preterm infants. Future studies correlating near infrared spectroscopy parameters and caffeine therapy are needed to determine the short/long-term effect of caffeine in preterm infants.


Assuntos
Cafeína , Recém-Nascido Prematuro , Recém-Nascido , Humanos , Lactente , Cafeína/farmacologia , Espectroscopia de Luz Próxima ao Infravermelho , Estudos Prospectivos , Idade Gestacional , Oxigênio
11.
Acta Paediatr ; 113(4): 677-683, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37970733

RESUMO

AIM: To investigate cerebral blood volume (CBV) in preterm neonates using time-resolved near-infrared spectroscopy. METHODS: In this prospective observational study, time-resolved near-infrared spectroscopy measurements of CBV using tNIRS-1 were performed in 70 preterm neonates. For measurements, a sensor was placed for a duration of 1 min, followed by four further reapplications of the sensor, overall five measurements. RESULTS: In this study, 70 preterm neonates with a mean ± SD gestational age of 33.4 ± 1.7 weeks and a birthweight of 1931 ± 398 g were included with a postnatal age of 4.7 ± 2.0 days. Altogether, 2383 CBV values were obtained with an overall mean of 1.85 ± 0.30 mL/100 g brain. A total of 95% of the measured CBV values varied in a range from -0.31 to 0.33 from the overall individual mean. Taking the deviation of the mean of each single application for each patient, this range reduced from -0.07 to 0.07. The precision of the measurement defined as within-variation in CBV was 0.24 mL/100 g brain. CONCLUSION: The overall mean CBV in stable preterm neonates was 1.85 ± 0.30 mL/100 g brain. The within-variation in CBV was 0.24 mL/100 g brain. Based on the precision obtained by our data, CBV of 1.85 ± 0.30 mL/100 g brain may be assumed as normal value for this cohort.


Assuntos
Volume Sanguíneo Cerebral , Espectroscopia de Luz Próxima ao Infravermelho , Recém-Nascido , Humanos , Lactente , Valores de Referência , Circulação Cerebrovascular , Encéfalo/diagnóstico por imagem , Oxigênio
12.
Acta Paediatr ; 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39115093

RESUMO

AIM: To establish reference ranges of peripheral-muscle regional oxygen saturation (prSO2) and peripheral fractional tissue oxygen extraction (pFTOE) during the first 15 min after birth in stable term neonates. METHODS: Secondary outcome parameters of prospective observational studies in healthy term neonates delivered by Caesarean section were analysed. prSO2 was measured on the right forearm using the INVOS 5100C monitor. pFTOE was calculated out of prSO2 and arterial oxygen saturation (SpO2). Centile charts (10th-90th) of prSO2 and pFTOE were defined during the first 15 min after birth. RESULTS: Three-hundred-five term neonates with a mean gestational age and birth weight of 39.0 ± 0.9 weeks and 3321 ± 454 g, respectively, were included. The 50th centiles of prSO2 were 39% (minute two), 52% (minute five), 71% (minute 10), and 73% (minute 15). The 50th centiles of pFTOE were 0.529 (minute two), 0.378 (minute five), 0.237 (minute 10), and 0.231 (minute 15). CONCLUSION: Reference ranges of prSO2 and pFTOE were established for term neonates delivered by Caesarean section during the immediate transition after birth. These reference ranges increase knowledge of physiological processes taking place immediately after birth and are necessary for possible future clinical applications.

13.
Adv Physiol Educ ; 48(3): 566-572, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38779745

RESUMO

Monitoring the metabolic cost or oxygen consumption associated with rest and exercise is crucial to understanding the impact of disease or physical training on the health of individuals. Traditionally, measuring the skeletal muscle oxygen cost associated with exercise/muscle contractions can be rather expensive or invasive (i.e., muscle biopsies). More recently, specific protocols designed around the use of near-infrared spectroscopy (NIRS) have been shown to provide a quick, noninvasive easy-to-use tool to measure skeletal muscle oxygen consumption ([Formula: see text]). However, the data and results from NIRS devices are often misunderstood. Thus the primary purpose of this sourcebook update is to provide several experimental protocols students can utilize to improve their understanding of NIRS technology, learn how to analyze results from NIRS devices, and better understand how muscle contraction intensity and type (isometric, concentric, or eccentric) influence the oxygen cost of muscle contractions.NEW & NOTEWORTHY Compared to traditional methods, near-infrared spectroscopy (NIRS) provides a relatively cheap and easy-to-use noninvasive technique to measure skeletal muscle oxygen uptake following exercise. This laboratory not only enables students to learn about the basics of NIRS and muscle energetics but also addresses more complex questions regarding skeletal muscle physiology.


Assuntos
Músculo Esquelético , Consumo de Oxigênio , Espectroscopia de Luz Próxima ao Infravermelho , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Humanos , Músculo Esquelético/metabolismo , Músculo Esquelético/fisiologia , Consumo de Oxigênio/fisiologia , Fisiologia/educação , Fisiologia/métodos , Oxigênio/metabolismo , Contração Muscular/fisiologia , Exercício Físico/fisiologia
14.
Sensors (Basel) ; 24(13)2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-39000941

RESUMO

Functional Near Infrared Spectroscopy (fNIRS) and Electroencephalography (EEG) are commonly employed neuroimaging methods in developmental neuroscience. Since they offer complementary strengths and their simultaneous recording is relatively easy, combining them is highly desirable. However, to date, very few infant studies have been conducted with NIRS-EEG, partly because analyzing and interpreting multimodal data is challenging. In this work, we propose a framework to carry out a multivariate pattern analysis that uses an NIRS-EEG feature matrix, obtained by selecting EEG trials presented within larger NIRS blocks, and combining the corresponding features. Importantly, this classifier is intended to be sensitive enough to apply to individual-level, and not group-level data. We tested the classifier on NIRS-EEG data acquired from five newborn infants who were listening to human speech and monkey vocalizations. We evaluated how accurately the model classified stimuli when applied to EEG data alone, NIRS data alone, or combined NIRS-EEG data. For three out of five infants, the classifier achieved high and statistically significant accuracy when using features from the NIRS data alone, but even higher accuracy when using combined EEG and NIRS data, particularly from both hemoglobin components. For the other two infants, accuracies were lower overall, but for one of them the highest accuracy was still achieved when using combined EEG and NIRS data with both hemoglobin components. We discuss how classification based on joint NIRS-EEG data could be modified to fit the needs of different experimental paradigms and needs.


Assuntos
Eletroencefalografia , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Eletroencefalografia/métodos , Recém-Nascido , Lactente , Masculino , Feminino , Encéfalo/fisiologia , Encéfalo/diagnóstico por imagem
15.
Sensors (Basel) ; 24(5)2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38474955

RESUMO

Human skin acts as a protective barrier, preserving bodily functions and regulating water loss. Disruption to the skin barrier can lead to skin conditions and diseases, emphasizing the need for skin hydration monitoring. The gold-standard sensing method for assessing skin hydration is the Corneometer, monitoring the skin's electrical properties. It relies on measuring capacitance and has the advantage of precisely detecting a wide range of hydration levels within the skin's superficial layer. However, measurement errors due to its front end requiring contact with the skin, combined with the bipolar configuration of the electrodes used and discrepancies due to variations in various interfering analytes, often result in significant inaccuracy and a need to perform measurements under controlled conditions. To overcome these issues, we explore the merits of a different approach to sensing electrical properties, namely, a tetrapolar bioimpedance sensing approach, with the merits of a novel optical sensing modality. Tetrapolar bioimpedance allows for the elimination of bipolar measurement errors, and optical spectroscopy allows for the identification of skin water absorption peaks at wavelengths of 970 nm and 1450 nm. Employing both electrical and optical sensing modalities through a multimodal approach enhances skin hydration measurement sensitivity and validity. This layered approach may be particularly beneficial for minimising errors, providing a more robust and comprehensive tool for skin hydration assessment. An ex vivo desorption experiment was carried out on fresh porcine skin, and an in vivo indicative case study was conducted utilising the developed optical and bioimpedance sensing devices. Expected outcomes were expressed from both techniques, with an increase in the output of the optical sensor voltage and a decrease in bioimpedance as skin hydration decreased. MLR models were employed, and the results presented strong correlations (R-squared = 0.996 and p-value = 6.45 × 10-21), with an enhanced outcome for hydration parameters when both modalities were combined as opposed to independently, highlighting the advantage of the multimodal sensing approach for skin hydration assessment.


Assuntos
Água Corporal , Dermatopatias , Humanos , Pele , Dermatopatias/diagnóstico , Água , Análise Espectral
16.
Sensors (Basel) ; 24(11)2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38894153

RESUMO

As a non-destructive, fast, and cost-effective technique, near-infrared (NIR) spectroscopy has been widely used to determine the content of bioactive components in tea. However, due to the similar chemical structures of various catechins in black tea, the NIR spectra of black tea severely overlap in certain bands, causing nonlinear relationships and reducing analytical accuracy. In addition, the number of NIR spectral wavelengths is much larger than that of the modeled samples, and the small-sample learning problem is rather typical. These issues make the use of NIRS to simultaneously determine black tea catechins challenging. To address the above problems, this study innovatively proposed a wavelength selection algorithm based on feature interval combination sensitivity segmentation (FIC-SS). This algorithm extracts wavelengths at both coarse-grained and fine-grained levels, achieving higher accuracy and stability in feature wavelength extraction. On this basis, the study built four simultaneous prediction models for catechins based on extreme learning machines (ELMs), utilizing their powerful nonlinear learning ability and simple model structure to achieve simultaneous and accurate prediction of catechins. The experimental results showed that for the full spectrum, the ELM model has better prediction performance than the partial least squares model for epicatechin (EC), epicatechin gallate (ECG), epigallocatechin (EGC), and epigallocatechin gallate (EGCG). For the feature wavelengths, our proposed FIC-SS-ELM model enjoys higher prediction performance than ELM models based on other wavelength selection algorithms; it can simultaneously and accurately predict the content of EC (Rp2 = 0.91, RMSEP = 0.019), ECG (Rp2 = 0.96, RMSEP = 0.11), EGC (Rp2 = 0.97, RMSEP = 0.15), and EGCG (Rp2 = 0.97, RMSEP = 0.35) in black tea. The results of this study provide a new method for the quantitative determination of the bioactive components of black tea.


Assuntos
Algoritmos , Catequina , Espectroscopia de Luz Próxima ao Infravermelho , Chá , Catequina/análise , Catequina/química , Catequina/análogos & derivados , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Chá/química , Análise dos Mínimos Quadrados , Aprendizado de Máquina
17.
Sensors (Basel) ; 24(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38610488

RESUMO

Near-infrared spectroscopy (NIRS) during repeated limb occlusions is a noninvasive tool for assessing muscle oxidative capacity. However, the method's reliability and validity remain under investigation. This study aimed to determine the reliability of the NIRS-derived mitochondrial power of the musculus vastus lateralis and its correlation with whole-body (cycling) aerobic power (V̇O2 peak). Eleven healthy active men (28 ± 10 y) twice (2 days apart) underwent repeated arterial occlusions to induce changes in muscle oxygen delivery after 15 s of electrical muscle stimulation. The muscle oxygen consumption (mV̇O2) recovery time and rate (k) constants were calculated from the NIRS O2Hb signal. We assessed the reliability (coefficient of variation and intraclass coefficient of correlation [ICC]) and equivalency (t-test) between visits. The results showed high reproducibility for the mV̇O2 recovery time constant (ICC = 0.859) and moderate reproducibility for the k value (ICC = 0.674), with no significant differences between visits (p > 0.05). NIRS-derived k did not correlate with the V̇O2 peak relative to body mass (r = 0.441, p = 0.17) or the absolute V̇O2 peak (r = 0.366, p = 0.26). In conclusion, NIRS provides a reproducible estimate of muscle mitochondrial power, which, however, was not correlated with whole-body aerobic capacity in the current study, suggesting that even if somewhat overlapping, not the same set of factors underpin these distinct indices of aerobic capacity at the different (peripheral and whole-body systemic) levels.


Assuntos
Músculo Quadríceps , Espectroscopia de Luz Próxima ao Infravermelho , Masculino , Humanos , Reprodutibilidade dos Testes , Ciclismo , Estimulação Elétrica
18.
Sensors (Basel) ; 24(10)2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38794026

RESUMO

Participant movement is a major source of artifacts in functional near-infrared spectroscopy (fNIRS) experiments. Mitigating the impact of motion artifacts (MAs) is crucial to estimate brain activity robustly. Here, we suggest and evaluate a novel application of the nonlinear Hammerstein-Wiener model to estimate and mitigate MAs in fNIRS signals from direct-movement recordings through IMU sensors mounted on the participant's head (head-IMU) and the fNIRS probe (probe-IMU). To this end, we analyzed the hemodynamic responses of single-channel oxyhemoglobin (HbO) and deoxyhemoglobin (HbR) signals from 17 participants who performed a hand tapping task with different levels of concurrent head movement. Additionally, the tapping task was performed without head movements to estimate the ground-truth brain activation. We compared the performance of our novel approach with the probe-IMU and head-IMU to eight established methods (PCA, tPCA, spline, spline Savitzky-Golay, wavelet, CBSI, RLOESS, and WCBSI) on four quality metrics: SNR, △AUC, RMSE, and R. Our proposed nonlinear Hammerstein-Wiener method achieved the best SNR increase (p < 0.001) among all methods. Visual inspection revealed that our approach mitigated MA contaminations that other techniques could not remove effectively. MA correction quality was comparable with head- and probe-IMUs.


Assuntos
Artefatos , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Masculino , Adulto , Feminino , Movimento/fisiologia , Movimento (Física) , Oxiemoglobinas/análise , Encéfalo/fisiologia , Adulto Jovem , Hemoglobinas/análise , Algoritmos , Processamento de Sinais Assistido por Computador , Hemodinâmica/fisiologia
19.
Molecules ; 29(4)2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38398532

RESUMO

Protein adulteration is a common fraud in the food industry due to the high price of protein sources and their limited availability. Total nitrogen determination is the standard analytical technique for quality control, which is incapable of distinguishing between protein nitrogen and nitrogen from non-protein sources. Three benchtops and one handheld near-infrared spectrometer (NIRS) with different signal processing techniques (grating, Fourier transform, and MEM-micro-electro-mechanical system) were compared with detect adulteration in protein powders at low concentration levels. Whey, beef, and pea protein powders were mixed with a different combination and concentration of high nitrogen content compounds-namely melamine, urea, taurine, and glycine-resulting in a total of 819 samples. NIRS, combined with chemometric tools and various spectral preprocessing techniques, was used to predict adulterant concentrations, while the limit of detection (LOD) and limit of quantification (LOQ) were also assessed to further evaluate instrument performance. Out of all devices and measurement methods compared, the most accurate predictive models were built based on the dataset acquired with a grating benchtop spectrophotometer, reaching R2P values of 0.96 and proximating the 0.1% LOD for melamine and urea. Results imply the possibility of using NIRS combined with chemometrics as a generalized quality control tool for protein powders.


Assuntos
Nitrogênio , Espectroscopia de Luz Próxima ao Infravermelho , Animais , Bovinos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Pós , Soro do Leite , Ureia , Contaminação de Alimentos/análise
20.
Khirurgiia (Mosk) ; (6): 20-27, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38888015

RESUMO

OBJECTIVE: To evaluate prognostic significance of tissue oximetry in healing of trophic defects in patients with diabetic foot syndrome (DFS) after endovascular revascularization. MATERIAL AND METHODS: In 42 patients with DFS, tissue oximetry was performed in angiosome projection with the FORE-SIGHT MC-2000 (CASMED) device before and the next day after revascularization of lower limb arteries. The 1st group included 30 patients with wound healing throughout 3 months, the 2nd group included 12 patients with amputation or no healing of trophic defects. RESULTS: Direct revascularization was more common in the 1st group (p=0.001). On the day after intervention, oxygen saturation (StO2) increased in all angiosomes in both groups (p<0.05). StO2 increment differed significantly between groups in all angiosomes except for point I (p<0.05). According to ROC analysis, StO2 increment by 4.5% in absolute values and 7.9% in percentage leads to trophic defect healing within 3 months (sensitivity and specificity were 76.7% and 66.7% for absolute values, 80% and 58.3% for percentage, respectively). CONCLUSION: Evaluation of StO2 in target angiosome may be valuable to predict trophic defect healing after endovascular surgery.


Assuntos
Pé Diabético , Oximetria , Cicatrização , Humanos , Pé Diabético/cirurgia , Pé Diabético/diagnóstico , Pé Diabético/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Oximetria/métodos , Cicatrização/fisiologia , Idoso , Procedimentos Endovasculares/métodos , Prognóstico , Saturação de Oxigênio/fisiologia , Resultado do Tratamento , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Extremidade Inferior/irrigação sanguínea
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA