Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Metabolomics ; 20(2): 43, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38491253

RESUMO

INTRODUCTION: Pre-analytical factors like sex, age, and blood processing methods introduce variability and bias, compromising data integrity, and thus deserve close attention. OBJECTIVES: This study aimed to explore the influence of participant characteristics (age and sex) and blood processing methods on the metabolic profile. METHOD: A Thermo UPLC-TSQ-Quantiva-QQQ Mass Spectrometer was used to analyze 175 metabolites across 9 classes in 208 paired serum and lithium heparin plasma samples from 51 females and 53 males. RESULTS: Comparing paired serum and plasma samples from the same cohort, out of the 13 metabolites that showed significant changes, 4 compounds related to amino acids and derivatives had lower levels in plasma, and 5 other compounds had higher levels in plasma. Sex-based analysis revealed 12 significantly different metabolites, among which most amino acids and derivatives and nitrogen-containing compounds were higher in males, and other compounds were elevated in females. Interestingly, the volcano plot also confirms the similar patterns of amino acids and derivatives higher in males. The age-based analysis suggested that metabolites may undergo substantial alterations during the 25-35-year age range, indicating a potential metabolic turning point associated with the age group. Moreover, a more distinct difference between the 25-35 and above 35 age groups compared to the below 25 and 25-35 age groups was observed, with the most significant compound decreased in the above 35 age groups. CONCLUSION: These findings may contribute to the development of comprehensive metabolomics analyses with confounding factor-based adjustment and enhance the reliability and interpretability of future large-scale investigations.


Assuntos
Metabolômica , Plasma , Masculino , Adulto , Feminino , Humanos , Metabolômica/métodos , Reprodutibilidade dos Testes , Plasma/química , Soro , Aminoácidos/análise
2.
Metabolomics ; 18(11): 82, 2022 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-36282338

RESUMO

INTRODUCTION: Metabolite stability is critical for tissue metabolomics. However, changes in metabolites in tissues over time from the operating room to the laboratory remain underexplored. OBJECTIVES: In this study, we evaluated the effect of postoperative freezing delay time on the stability of metabolites in normal and oral squamous cell carcinoma (OSCC) tissues. METHODS: Tumor and paired normal tissues from five OSCC patients were collected after surgical resection, and samples was sequentially quenched in liquid nitrogen at 30, 40, 50, 60, 70, 80, 90 and 120 min (80 samples). Untargeted metabolic analysis by liquid chromatography-mass spectrometry/mass spectrometry in positive and negative ion modes was used to identify metabolic changes associated with delayed freezing time. The trends of metabolite changes at 30-120 and 30-60 min of delayed freezing were analyzed. RESULTS: 190 metabolites in 36 chemical classes were detected. After delayed freezing for 120 min, approximately 20% of the metabolites changed significantly in normal and tumor tissues, and differences in the metabolites were found in normal and tumor tissues. After a delay of 60 min, 29 metabolites had changed significantly in normal tissues, and 84 metabolites had changed significantly in tumor tissues. In addition, we constructed three tissue freezing schemes based on the observed variation trends in the metabolites. CONCLUSION: Delayed freezing of tissue samples has a certain impact on the stability of metabolites. For metabolites with significant changes, we suggest that the freezing time of tissues be reasonably selected according to the freezing schemes and the actual clinical situation.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Neoplasias Bucais , Humanos , Metabolômica/métodos , Congelamento , Carcinoma de Células Escamosas de Cabeça e Pescoço , Nitrogênio
3.
Neurochem Res ; 46(3): 447-454, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33249516

RESUMO

Gene expression studies are reported to be influenced by pre-analytical factors that can compromise RNA yield and integrity, which in turn may confound the experimental findings. Here we investigate the impact of four pre-analytical factors on brain-derived RNA: time-before-collection, tissue specimen size, tissue collection method, and RNA isolation method. We report no significant differences in RNA yield or integrity between 20 mg and 60 mg tissue samples collected in either liquid nitrogen or the RNAlater stabilizing solution. Isolation of RNA employing the TRIzol reagent resulted in a higher yield compared to isolation via the QIAcube kit while the latter resulted in RNA of slightly better integrity. Keeping brain tissue samples at room temperature for up to 160 min prior to collection and isolation of RNA resulted in no significant difference in yield or integrity. Our findings have significant practical and financial consequences for clinical genomic departments and other laboratory settings performing large-scale routine RNA expression analysis of brain samples.


Assuntos
Encéfalo/metabolismo , RNA/metabolismo , Animais , Camundongos , RNA/isolamento & purificação , Estabilidade de RNA , Manejo de Espécimes/métodos , Temperatura , Fatores de Tempo
4.
Expert Rev Proteomics ; 15(8): 683-696, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30058389

RESUMO

INTRODUCTION: The development of precision medicine requires advanced technologies to address the multifactorial disease stratification and to support personalized treatments. Among omics techniques, proteomics based on Mass Spectrometry (MS) is becoming increasingly relevant in clinical practice allowing a phenotypic characterization of the dynamic functional status of the organism. From this perspective, Matrix Assisted Laser Desorption Ionization Time of Flight (MALDI-TOF) MS is a suitable platform for providing a high-throughput support to clinics. Areas covered: This review aims to provide an updated overview of MALDI-TOF MS applications in clinical proteomics. The most relevant features of this analysis have been discussed, highlighting both pre-analytical and analytical factors that are crucial in proteomics studies. Particular emphasis is placed on biofluids proteomics for biomarkers discovery and on recent progresses in clinical microbiology, drug monitoring, and minimal residual disease (MRD). Expert commentary: Despite some analytical limitations, the latest technological advances together with the easiness of use, the low time and low cost consuming and the high throughput are making MALDI-TOF MS instruments very attractive for the clinical practice. These features offer a significant potential for the routine of the clinical laboratory and ultimately for personalized medicine.


Assuntos
Proteômica , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Líquidos Corporais/metabolismo , Descoberta de Drogas , Humanos , Neoplasia Residual/metabolismo
5.
Pediatr Blood Cancer ; 65(10): e27248, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29923309

RESUMO

Measurement of the urine catecholamine metabolites homovanillic acid (HVA) and vanillylmandelic acid (VMA) are the standard method for detecting disease recurrence in neuroblastoma. We present a case of abnormal concentrations of catecholamine metabolites that prompted investigations for relapsed neuroblastoma. However, further study revealed that the abnormal biochemistry was likely due to ingestion of olives. Olive ingestion should be considered when interpreting urine HVA and VMA results, and excluded if concentrations are unexpectedly abnormal.


Assuntos
Ácido Homovanílico/urina , Recidiva Local de Neoplasia/diagnóstico , Neuroblastoma/diagnóstico , Olea/metabolismo , Ácido Vanilmandélico/urina , Pré-Escolar , Feminino , Humanos , Recidiva Local de Neoplasia/urina , Neuroblastoma/patologia , Neuroblastoma/urina
6.
Metabolites ; 14(4)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38668328

RESUMO

As end-products of the intersection between the genome and environmental influences, metabolites represent a promising approach to the discovery of novel biomarkers for diseases. However, many potential biomarker candidates identified by metabolomics studies fail to progress beyond analytical validation for routine implementation in clinics. Awareness of the challenges present can facilitate the development and advancement of innovative strategies that allow improved and more efficient applications of metabolite-based markers in clinical settings. This minireview provides a comprehensive summary of the pre-analytical factors, required analytical validation studies, and kit development challenges that must be resolved before the successful translation of novel metabolite biomarkers originating from research. We discuss the necessity for strict protocols for sample collection, storage, and the regulatory requirements to be fulfilled for a bioanalytical method to be considered as analytically validated. We focus especially on the blood as a biological matrix and liquid chromatography coupled with tandem mass spectrometry as the analytical platform for biomarker validation. Furthermore, we examine the challenges of developing a commercially viable metabolomics kit for distribution. To bridge the gap between the research lab and clinical implementation and utility of relevant metabolites, the understanding of the translational challenges for a biomarker panel is crucial for more efficient development of metabolomics-based precision medicine.

7.
Alzheimers Res Ther ; 16(1): 31, 2024 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-38331843

RESUMO

INTRODUCTION: Pre-analytical factors can cause substantial variability in the measurements of cerebrospinal fluid (CSF) and plasma biomarkers of Alzheimer's disease (AD). However, their effects on the performance of one of the most promising plasma AD biomarkers, phosphorylated tau (p-tau)217, are not known. METHODS: We included 50 amyloid-ß positive (Aß+) and 50 Aß- participants from the Swedish BioFINDER-1 study. Plasma and CSF p-tau217 were measured using an immunoassay developed by Lilly Research Laboratories. We examined the effect of four plasma handling conditions, i.e., (1) thawing at room temperature (RT) with no centrifugation, (2) thawing at RT followed by centrifugation, (3) thawing on ice with no centrifugation, and (4) thawing on ice followed by centrifugation. In addition, we also tested the effects of up to 3 freeze-thaw cycles on the associations of plasma p-tau217 with AD-related pathologies measured with CSF p-tau217 and CSF Aß42/Aß40. RESULTS: In the whole cohort (combining Aß+ and Aß- participants), we found significant correlations between plasma p-tau217 and both CSF p-tau217 (Rrange, 0.614-0.717, p < 0.001) and CSF Aß42/Aß40 (Spearman Rrange, - 0.515 to - 0.652, p < 0.001) for each of the four tested conditions. Correlations between plasma and CSF p-tau217 were also significant for all conditions in the Aß+ group (Rrange, 0.506-0.579, p < 0.001). However, in this Aß+ subgroup, correlations with CSF Aß42/Aß40 were only significant for centrifuged samples (thawed at RT, R = - 0.394, p = 0.010; thawed on ice, R = - 0.406; p = 0.007). In Aß- participants, correlations between plasma and CSF p-tau217 were again significant only for centrifuged samples (thawed at RT, R = 0.394, p = 0.007; thawed on ice, R = 0.334; p = 0.022), with no correlations seen between plasma p-tau217 and CSF Aß42/Aß40 for any of the conditions. While the accuracy of plasma p-tau217 to identify individuals with abnormal CSF Aß42/Aß40 or CSF p-tau217 status was high, the AUCs for samples thawed at RT and analyzed without centrifugation were numerically lower than the AUCs of other conditions (CSF Aß42/Aß40 = 0.845 vs 0.872-0.884; CSF p-tau217 = 0.866 vs 0.908-0.924, pdiff > 0.11). P-tau217 concentration was consistently higher in non-centrifuged samples than in centrifuged samples (p ≤ 0.021). There were no differences between samples freeze-thawed once, twice, or three times. CONCLUSION: Centrifugation improved the performance of plasma p-tau217, but thawing temperatures and up to three freeze-thaw cycles did not have a significant impact. These results may inform the future development of standardized sample-handling protocols for AD biomarkers.


Assuntos
Doença de Alzheimer , Gelo , Humanos , Fragmentos de Peptídeos/líquido cefalorraquidiano , Doença de Alzheimer/líquido cefalorraquidiano , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Biomarcadores/líquido cefalorraquidiano , Proteínas tau/líquido cefalorraquidiano
8.
Metabolites ; 14(1)2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38248839

RESUMO

This review article compiles critical pre-analytical factors for sample collection and extraction of eight uncommon or underexplored biological specimens (human breast milk, ocular fluids, sebum, seminal plasma, sweat, hair, saliva, and cerebrospinal fluid) under the perspective of clinical metabolomics. These samples are interesting for metabolomics studies as they reflect the status of living organisms and can be applied for diagnostic purposes and biomarker discovery. Pre-collection and collection procedures are critical, requiring protocols to be standardized to avoid contamination and bias. Such procedures must consider cleaning the collection area, sample stimulation, diet, and food and drug intake, among other factors that impact the lack of homogeneity of the sample group. Precipitation of proteins and removal of salts and cell debris are the most used sample preparation procedures. This review intends to provide a global view of the practical aspects that most impact results, serving as a starting point for the designing of metabolomic experiments.

9.
Biopreserv Biobank ; 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37878356

RESUMO

Development of novel biomarkers for diagnosis of disease and assessment of treatment efficacy utilizes a wide range of biospecimens for discovery research. The fitness of biospecimens for the purpose of biomarker development depends on the clinical characteristics of the donor and on a number of critical and potentially uncontrolled pre-analytical variables. Pre-analytical factors influence the reliability of the biomarkers to be analyzed and can seriously impact analytic outcomes. Sample quality stratification assays and tools can be utilized by biorepositories to minimize bias resulting from samples' inconsistent quality. In this study, we evaluated the quality of biobanked specimens by comparing analytical outcomes at 1, 5, and 10 years after collection. Our results demonstrate that currently available assays and tools can be used by biobank laboratories to support objective biospecimen qualification. We have established a workflow to monitor the quality of different types of biospecimens and, in this study, present the results of a qualification exercise applied to fluid samples and their derivatives in the context of urological diseases.

10.
Afr J Lab Med ; 12(1): 2239, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38222270

RESUMO

Background: Accurate potassium measurements are necessary for effective clinical management of hyperkalaemia. Pre-analytical factors may affect laboratory measurements, leading to erroneous results and inappropriate patient management and negatively impact the efficiency and finances of laboratories and hospitals. Objective: This study evaluated the impact of rejected potassium test requests on laboratory service. Methods: We conducted a retrospective descriptive study to assess potassium test data at a public laboratory in Pretoria, Gauteng, South Africa, using samples collected from an academic hospital, peripheral hospitals, and outpatient clinics between January 2018 to December 2018. We assessed the relationship between reasons for rejection and health facility type, as well as financial implications for the laboratory. Results: The potassium result rejection rate was 15.1% (29 806 samples), out of the 197 405 requests received. The most common reasons for rejection were old sample (> 1 day old) (41.4%; 12 348 rejections) and haemolysis (38.2%; 11 398 rejections). The most frequent reason for rejections at the central, academic hospital was haemolysis (42.0%), while old sample was the most common reason for rejection at peripheral hospitals (43.4%; 4119/9493 requests) and outpatient health facilities (57.2%; 7208/12 605 requests) (p = 0.022). The total cost of potassium sample rejection over the study period was substantial, given the resource constraints in this setting. Conclusion: Peripheral hospitals and outpatient departments accounted for the majority of rejected potassium testing results, possibly resulting from delays in transportation; causing substantial financial impact on the laboratory. Improved sample collection, handling, and expedited transportation are recommended. What this study adds: This study highlights the importance of appropriate sample collection and handling and the undesirable consequences of non-adherence to these pre-analytical considerations.

11.
Front Med (Lausanne) ; 10: 1278641, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38259852

RESUMO

Nicotinamide adenine dinucleotide (NAD+), a coenzyme for more than 500 enzymes, plays a central role in energy production, metabolism, cellular signaling, and DNA repair. Until recently, NAD+ was primarily considered to be an intracellular molecule (iNAD+), however, its extracellular species (eNAD+) has recently been discovered and has since been associated with a multitude of pathological conditions. Therefore, accurate quantification of eNAD+ in bodily fluids such as plasma is paramount to answer important research questions. In order to create a clinically meaningful and reliable quantitation method, we analyzed the relationship of cell lysis, routine clinical laboratory parameters, blood collection techniques, and pre-analytical processing steps with measured plasma eNAD+ concentrations. Initially, NAD+ levels were assessed both intracellularly and extracellularly. Intriguingly, the concentration of eNAD+ in plasma was found to be approximately 500 times lower than iNAD+ in peripheral blood mononuclear cells (0.253 ± 0.02 µM vs. 131.8 ± 27.4 µM, p = 0.007, respectively). This stark contrast suggests that cellular damage or cell lysis could potentially affect the levels of eNAD+ in plasma. However, systemic lactate dehydrogenase in patient plasma, a marker of cell damage, did not significantly correlate with eNAD+ (n = 33; r = -0.397; p = 0.102). Furthermore, eNAD+ was negatively correlated with increasing c-reactive protein (CRP, n = 33; r = -0.451; p = 0.020), while eNAD+ was positively correlated with increasing hemoglobin (n = 33; r = 0.482; p = 0.005). Next, variations in blood drawing, sample handling and pre-analytical processes were examined. Sample storage durations at 4°C (0-120 min), temperature (0° to 25°C), cannula sizes for blood collection and tourniquet times (0 - 120 s) had no statistically significant effect on eNAD+ (p > 0.05). On the other hand, prolonged centrifugation (> 5 min) and a faster braking mode of the centrifuge rotor (< 4 min) resulted in a significant decrease in eNAD+ levels (p < 0.05). Taken together, CRP and hemoglobin appeared to be mildly correlated with eNAD+ levels whereas cell damage was not correlated significantly to eNAD+ levels. The blood drawing trial did not show any influence on eNAD+, in contrast, the preanalytical steps need to be standardized for accurate eNAD+ measurement. This work paves the way towards robust eNAD+ measurements, for use in future clinical and translational research, and provides an optimized hands-on protocol for reliable eNAD+ quantification in plasma.

12.
Clin Chim Acta ; 520: 168-171, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34081934

RESUMO

The analysis of circulating cell free DNA is an important tool for the analysis of tumor resistance, tumor heterogeneity, detection of minimal residual disease and detection of allograft rejection in kidney or heart transplant patients. The proper use of this technique is important, and starts with considering pre-analytic aspects. The current paper addresses some important technical considerations to ensure the proper and harmonized use of cfDNA techniques.


Assuntos
Ácidos Nucleicos Livres , DNA Tumoral Circulante , Biomarcadores Tumorais/genética , DNA Tumoral Circulante/genética , Testes Diagnósticos de Rotina , Humanos , Neoplasia Residual
13.
Epigenetics ; 16(7): 797-807, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33074045

RESUMO

The methylation pattern of cfDNA, isolated from liquid biopsies, is gaining substantial interest for diagnosis and monitoring of diseases. We have evaluated the impact of type of blood collection tube and time delay between blood draw and plasma preparation on bisulphite-based cfDNA methylation profiling. Fifteen tubes of blood were drawn from three healthy volunteer subjects (BD Vacutainer K2E EDTA spray tubes, Streck Cell-Free DNA BCT tubes, PAXgene Blood ccfDNA tubes, Roche Cell-Free DNA Collection tubes and Biomatrica LBgard blood tubes in triplicate). Samples were either immediately processed or stored at room temperature for 24 or 72 hours before plasma preparation. DNA fragment size was evaluated by capillary electrophoresis. Reduced representation bisulphite sequencing was performed on the cell-free DNA isolated from these plasma samples. We evaluated the impact of blood tube and time delay on several quality control metrics. All preservation tubes performed similar on the quality metrics that were evaluated. Furthermore, a considerable increase in cfDNA concentration and the fraction of it derived from NK cells was observed after a 72-hour time delay in EDTA tubes. The methylation pattern of cfDNA is robust and reproducible in between the different preservation tubes. EDTA tubes processed as soon as possible, preferably within 24 hours, are the most cost effective. If immediate processing is not possible, preservation tubes are valid alternatives.


Assuntos
Ácidos Nucleicos Livres , Estudo de Associação Genômica Ampla , Coleta de Amostras Sanguíneas , Metilação de DNA , Epigenoma , Humanos , Biópsia Líquida
14.
Biomolecules ; 11(10)2021 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-34680097

RESUMO

Proinflammatory biomarkers have been increasingly used in epidemiologic and intervention studies over the past decades to evaluate and identify an association of systemic inflammation with cardiovascular diseases. Although there is a strong correlation between the elevated level of inflammatory biomarkers and the pathology of various cardiovascular diseases, the mechanisms of the underlying cause are unclear. Identification of pro-inflammatory biomarkers such as cytokines, chemokines, acute phase proteins, and other soluble immune factors can help in the early diagnosis of disease. The presence of certain confounding factors such as variations in age, sex, socio-economic status, body mass index, medication and other substance use, and medical illness, as well as inconsistencies in methodological practices such as sample collection, assaying, and data cleaning and transformation, may contribute to variations in results. The purpose of the review is to identify and summarize the effect of demographic factors, epidemiological factors, medication use, and analytical and pre-analytical factors with a panel of inflammatory biomarkers CRP, IL-1b, IL-6, TNFa, and the soluble TNF receptors on the concentration of these inflammatory biomarkers in serum.


Assuntos
Biomarcadores/sangue , Doenças Cardiovasculares/sangue , Fatores Imunológicos/sangue , Inflamação/sangue , Proteína C-Reativa/metabolismo , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/genética , Humanos , Inflamação/diagnóstico , Inflamação/genética , Interleucina-1beta/sangue , Interleucina-6/sangue , Receptores do Fator de Necrose Tumoral/sangue , Fator de Necrose Tumoral alfa/sangue
15.
Metabolites ; 9(8)2019 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-31349624

RESUMO

Metabolomics provides a comprehensive assessment of numerous small molecules in biological samples. As it integrates the effects of exogenous exposures, endogenous metabolism, and genetic variation, metabolomics is well-suited for studies examining metabolic profiles associated with a variety of chronic diseases. In this review, we summarize the studies that have characterized the effects of various pre-analytical factors on both targeted and untargeted metabolomic studies involving human plasma, serum, and urine and were published through 14 January 2019. A standardized protocol was used for extracting data from full-text articles identified by searching PubMed and EMBASE. For plasma and serum samples, metabolomic profiles were affected by fasting status, hemolysis, collection time, processing delays, particularly at room temperature, and repeated freeze/thaw cycles. For urine samples, collection time and fasting, centrifugation conditions, filtration and the use of additives, normalization procedures and multiple freeze/thaw cycles were found to alter metabolomic findings. Consideration of the effects of pre-analytical factors is a particularly important issue for epidemiological studies where samples are often collected in nonclinical settings and various locations and are subjected to time and temperature delays prior being to processed and frozen for storage.

16.
Clin Chim Acta ; 494: 74-78, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30878539

RESUMO

The variability of Alzheimer's disease (AD) cerebrospinal fluid (CSF) biomarkers (Aß42, t-Tau and p-Tau) undermines their full-fledged introduction into routine diagnostics and clinical trials. The introduction of automatic systems can improve the diagnostic performance promoting standardization and reducing the impact of preanalytical and analytical factors. Here we assessed the diagnostic performance of a fully automated chemiluminescent enzyme assay (LUMIPULSE) and compared it with that obtained by using the classical manual enzyme-linked immunosorbent assays (ELISAs). Patients were clinically diagnosed as AD (n = 42) and non-AD (n = 38). Clinical diagnosis was confirmed at follow-up. LUMIPULSE Aß42 was reduced in AD (969.4 ±â€¯329.6 pg/mL vs. 1625.9 ±â€¯745.9 pg/mL, p <0.001), whereas LUMIPULSE t-Tau was increased in AD (768.2 ±â€¯281.0 pg/mL vs. 337.5 ±â€¯159.1 pg/mL, p < 0.001) compared to non-AD patients. Both LUMIPULSE Aß42 (AUC = 0.78, spec. = 0.74, sens. = 0.76) and t-Tau (AUC = 0.94, spec. = 0.93, sens. = 0.87) showed good accuracy in distinguish AD from non-AD and a high correlation with the manual ELISAs (r = 0.87, p < 0.001 and r = 0.92, p < 0.001, respectively). LUMIPULSE improves clinical accuracy in AD diagnosis, promoting the use of standardized values for CSF biomarkers with a good correlation with classical manual assays.


Assuntos
Doença de Alzheimer/diagnóstico , Automação , Ensaio de Imunoadsorção Enzimática , Medições Luminescentes , Idoso , Doença de Alzheimer/líquido cefalorraquidiano , Estudos de Coortes , Feminino , Humanos , Masculino
17.
Pract Lab Med ; 12: e00109, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30426060

RESUMO

OBJECTIVES: Deviation from manufacturers' pre-analytical sample handling recommendations necessitates extensive validation studies. This report uses plasma lactate testing, where a recommended 15 min room temperature sample handling limit cannot be met by the clinical laboratory, as an example for studies to bridge the gap with practice. DESIGN AND METHODS: Triplicate blood samples were collected from patients (n = 51) with lactate requests by clinicians and from normal volunteers (n = 50). One tube was transported on ice (4 °C), the others were maintained at room temperature (23 °C). Tubes stored at 4 °C were processed at 30 min from collection. Tubes stored at 23 °C were processed at 15 and at 30 min from collection. Lactate levels were measured using Roche Diagnostics Cobas 6000® analyzer. RESULTS: Lactate levels in normal subjects ranged from 0.6 to 3.1 mmol/L (median 1.1). Patient lactate levels ranged from 0.8 to 26.3 mmol/L (median 2.2). Bias in lactate levels following extended storage of samples from both normal subjects and patients ranged from - 1.3 to2.2 and from - 1.0-1.0 mmol/L when stored for 30 min at 23 °C or at 4 °C, respectively. The bias between lactate levels at 30 min at 23 °C and 4 °C was - 1.2 to - 0.5 mmol/L for both populations. Although the bias was not statistically significant for all variables, a clinically significant (>0.2 mmol/L) bias was observed in 28% of normal and 7.0% of patient samples. CONCLUSION: Extending the pre-analytical time to 30 min at 23 °C did not significantly impact clinical utility of lactate measurement in our patient population.

18.
Clin Chim Acta ; 478: 37-43, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29258744

RESUMO

BACKGROUND: In vitro deamination generates ammonia in freshly collected blood specimens. To prevent this, samples for ammonia testing are usually collected on ice and run rapidly (e.g., within 1h). We developed a method to stabilize specimens for ammonia analysis. METHODS: Following plasma separation, 500µmol/l cycloserine or a combination of 2mmol/l sodium borate with 5mmol/l l-serine were added to sample pools with normal or increased concentrations of ALT and/or GGT to inhibit deamination; and/or residual platelets were removed via centrifugation. Sample pools were then incubated at room temperature or 4°C. Untreated sample pools were also incubated at -80°C. Ammonia was measured at 0, 1, 2, 4, 8, 16, and 24h. RESULTS: When incubated at 4°C without treatment, sample pools with enzymes within their reference limit had an increase of 0.5µmol/l/h, whereas sample pools with ALT and/or GGT activity above their upper reference limit had an increase of 3.6µmol/l/h (p<0.001). When sample pools were incubated at 4°C with sodium borate/l-serine, the rate of ammonia increase was significantly reduced in samples with normal (0.3µmol/l/h, p<0.001 vs. untreated controls) or high enzyme activity (0.1µmol/l/h, p<0.001 vs. untreated controls). Independent of the ALT and/or GGT concentrations, storing the sample at -80°C also preserved the specimens for ammonia analysis (0.2µmol/l/h, p<0.001 vs. untreated controls). CONCLUSIONS: By combining sodium borate/l-serine with refrigeration, plasma ammonia specimens can be stabilized for >12h.


Assuntos
Amônia/sangue , Manejo de Espécimes/métodos , Amônia/química , Coleta de Amostras Sanguíneas/métodos , Boratos , Serviços de Laboratório Clínico , Criopreservação/métodos , Humanos , Serina , Temperatura
19.
J Immunol Methods ; 461: 53-62, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29906454

RESUMO

INTRODUCTION: Monocytes are important for innate immunity and include the classical (CD14brightCD16negative), intermediate (CD14brightCD16dim) and non-classical (CD14dimCD16bright) monocyte subsets. The quantification of these functionally different subsets in peripheral blood may become useful for diagnosis and follow-up in human diseases. The aim of the present study was to investigate how different pre-analytical parameters influence analysis of monocyte subsets in peripheral blood samples. METHODS: We determined relative levels of monocytes and monocyte subsets by flow cytometry of peripheral blood samples derived from healthy individuals. A gating strategy exclusively extracting viable CD14+ monocytes and focusing on the three monocyte subsets was applied. We investigated the effects of (i) various anticoagulants (i.e. Li-Heparin, ACD-A, K2EDTA), (ii) insufficient filling of blood sampling tubes, (iii) cryopreservation. In addition, we analysed expression of the CCR2 chemokine receptor. RESULTS: The relative numbers of CD14+ monocytes depended on the anticoagulant used, whereas the fraction of the three monocyte subsets did not. Insufficient filling of blood sampling tubes altered the relative levels of monocytes out of leukocytes, but not the relative levels of the monocyte subsets. Finally, the fraction of CD14+ monocytes out of isolated peripheral blood mononuclear cells was not significantly altered by cryopreservation, but the relative percentages of monocyte subsets was altered (similar effects for ACD-A and K2EDTA samples) and this was observed in correlation to a decreased CD16 expression. CONCLUDING REMARKS: Analysis of the monocyte subsets (i.e. classical, intermediate, non-classical) in peripheral blood samples requires a careful standardization of peripheral blood sampling and pre-analytic handling of the samples with respect to the anticoagulant used, filling of sample tubes, and cryopreservation of cells prior to analysis.


Assuntos
Criopreservação/normas , Receptores de Lipopolissacarídeos/sangue , Monócitos , Receptores CCR2/sangue , Receptores de IgG/sangue , Manejo de Espécimes/normas , Adulto , Criopreservação/métodos , Feminino , Humanos , Masculino , Monócitos/citologia , Monócitos/metabolismo , Manejo de Espécimes/métodos
20.
J. Bras. Patol. Med. Lab. (Online) ; 57: e3262021, 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1250142

RESUMO

ABSTRACT Introduction: Testosterone is the main hormone that regulates male reproductive functions, directly participating in spermatogenesis and increasing sexual activity. The blood measurement of this hormone is essential for the diagnosis of neuroendocrine disorders, such as hypogonadism. However, there is lack of standardization regarding patient preparation for the hormone collection in clinical laboratories. Objective: Evaluate the effect of pre-analytical variables, including fasting, circadian and seasonal variation on testosterone levels in healthy young males. Material and methods: Forty-two volunteers were selected for the study, in the city of Barbacena, Minas Gerais. Four blood samples were collected from each of the participants, three in the winter: the first one in the morning after fasting; the second in the afternoon, without fasting; the third, in the next day morning, without fasting; and the last one taken in the summer, in the morning, after fasting. Results: The analyses showed that there was a significant decrease in total testosterone levels when there was no fasting for eight hours prior to collection and in the afternoon compared to the morning, both with p < 0.001. There was no significant difference in the results obtained in winter and summer. Conclusion: It is recommended that clinical laboratories standardize the collection of total testosterone by performing the test in the morning and after an eight-hour fast, in order to reduce variability and ensure reliability in the results.


RESUMEN Introducción: La testosterona es la principal hormona reguladora de funciones reproductoras masculinas, participando directamente en la espermatogénesis y en el aumento de la actividad sexual. La medición sanguínea de esa hormona es fundamental en el diagnóstico de trastornos neuroendocrinos, como el hipogonadismo. Sin embargo, hay poca estandarización en la preparación adecuada del paciente para la recolección de la hormona en laboratorios clínicos. Objetivo: Evaluar el efecto de variables preanalíticas, incluyendo ayuno, variación circadiana y estacional en las mediciones de testosterona en hombres jóvenes sanos. Material y métodos: Se eligieron 42 voluntarios para el estudio, en la ciudad de Barbacena, Minas Gerais. Se tomaron cuatro muestras de sangre de cada uno de los participantes, de las cuales tres en invierno: la primera, matutina, en ayunas; la segunda, vespertina, sin ayunas; la tercera, el dia siguiente, matutina, sin ayunas; el última se recolectó en verano, por la mañana, en ayunas. Resultados: Los análisis demostraron que hubo reducción significativa en los niveles de testosterona total cuando no se realizó el ayuno de ocho horas antes de la recolección y en el período vespertino en comparación al matutino, ambos con valor de p < 0,001. No hubo diferencia significativa en los resultados obtenidos en invierno y en verano. Conclusión: Se recomienda que los laboratórios clínicos estandarizen la recolección de testosterona total con la realización de la prueba en el período matutino y en ayuno de ocho horas, para reducir la variación y garantizar la confiabilidad de los resultados.


RESUMO Introdução: A testosterona é o principal hormônio regulador das funções reprodutivas masculinas, participando diretamente da espermatogênese e do aumento da atividade sexual. A dosagem sanguínea desse hormônio é fundamental no diagnóstico de distúrbios neuroendócrinos, como o hipogonadismo. Entretanto, há pouca padronização no preparo adequado do paciente para a coleta do hormônio em laboratórios clínicos. Objetivo: Avaliar o efeito de variáveis pré-analíticas, incluindo realização de jejum, variação circadiana e sazonal nas dosagens de testosterona em jovens saudáveis do sexo masculino. Material e métodos: Foram selecionados 42 voluntários para o estudo, na cidade de Barbacena, Minas Gerais. Quatro amostras de sangue de cada um dos participantes foram coletadas, sendo três no inverno: a primeira de manhã, em jejum; a segunda à tarde, sem jejum; a terceira no dia seguinte, de manhã, sem jejum. A última foi coletada no verão, na parte da manhã, em jejum. Resultados: As análises demonstraram que houve diminuição significativa dos níveis de testosterona total quando não foi realizado jejum de 8 horas antes da coleta e no período da tarde em comparação ao período da manhã, ambos com valor de p < 0,001. Não houve diferença significativa nos resultados obtidos no inverno e no verão. Conclusão: Recomendamos que os laboratórios clínicos padronizem a coleta de testosterona total com a realização do exame no período da manhã e em jejum de 8 horas, a fim de reduzir a variabilidade e garantir a confiabilidade nos resultados.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA