Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 437
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Clin Oral Investig ; 28(8): 454, 2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39066793

RESUMO

PURPOSE: The main aim of the present study was to carry out a scoping review on the differences in degree of conversion of monomers regarding several types resin cements, indirect restorative materials, and light-curing procedures used in dentistry. METHOD: A bibliographic review was performed on PubMed using the following search items: "degree of conversion" OR "filler" AND "resin cement" OR "inorganic cement" AND "organic" OR "radiopacity" OR "refractive" OR "transmittance" OR "type" AND "resin composite." The search involved articles published in English language within the last thirteen years. A research question has been formulated following the PICO approach as follow: "How different is the degree of conversion of monomers comparing several types of resin-matrix cements?". RESULTS: Within the 15 selected studies, 8 studies reported a high degree of conversion (DC) of the organic matrix ranging from 70 up to 90% while 7 studies showed lower DC values. Dual-cured resin-matrix cements revealed the highest mean values of DC, flexural strength, and hardness when compared with light- and self-polymerized ones. DC mean values of resin-matrix cements light-cured through a ceramic veneer with 0.4 mm thickness were higher (~ 83%) than those recorded for resin-matrix cements light-cured through a thicker ceramic layer of 1.5 mm (~ 77%). CONCLUSIONS: The highest percentage of degree of conversion of monomers was reported for dual-cured resin-matrix cements and therefore both chemical and light-induced pathways promoted an enhanced polymerization of the material. Similar degree of conversion of the same resin-matrix cement were recorded when the prosthetic structure showed a low thickness. On thick prosthetic structures, translucent materials are required to allow the light transmission achieving the resin-matrix cement. CLINICAL RELEVANCE: The chemical composition of resin-matrix cements and the light-curing mode can affect the polymerization of the organic matrix. Thus, physical properties of the materials can vary leading to early clinical failures at restorative interfaces. Thus, the analysis of the polymerization pathways of resin-matrix cements is significantly beneficial for the clinical performance of the restorative interfaces.


Assuntos
Polimerização , Cimentos de Resina , Cimentos de Resina/química , Resinas Compostas/química , Teste de Materiais , Restauração Dentária Permanente/métodos , Humanos , Cura Luminosa de Adesivos Dentários
2.
J Esthet Restor Dent ; 2024 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-39373394

RESUMO

OBJECTIVE: To evaluate the plant-derived compound lignin (LIG) as a pretreatment of intraradicular dentin in combination with EDTA on push-out bond strength (PBS) and nanoleakage of the glass fiber posts (GFPs) cemented using adhesive resin cement. MATERIAL AND METHODS: Twenty-eight human incisor roots were prepared for GFP cementation and divided based on dentin pretreatment: (1) CONTROL: no pretreatment, (2) EDTA: 17% EDTA for 3 min, (3) EDTA-LIG: 17% EDTA and 2% lignin for 3 min, (4) EDTA-PAC: 17% EDTA and 2% lignin for 3 min. The GFPs were cemented using the self-adhesive resin cement Multilink Speed. The roots (n = 7) were sectioned into 1 mm-thick discs and subjected to PBS testing after 1 week or 6 months. Nanoleakage was analyzed by SEM. Statistical analysis was performed using two-factor ANOVA and Tukey's test (p < 0.05). RESULTS: Higher PBS was identified for the CONTROL group (p < 0.001). After 6 months, the EDTA-LIG maintained the bond strength with a predominance of mixed failures, while the EDTA-PAC, EDTA, and CONTROL groups showed reduction of bond strength, with a predominance of adhesive failures along with severe silver infiltration in the interface. CONCLUSION: LIG associated with EDTA as a pretreatment for intraradicular dentin shows significant potential for attaining stable bond strength and interfacial integrity of self-adhesive resin cement to intraradicular dentin.

3.
J Contemp Dent Pract ; 25(3): 226-230, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38690694

RESUMO

AIM: To assess the effectiveness of various surface treatments and adhesives on the bond strength of zirconia-based ceramic to dentin. MATERIALS AND METHODS: Eighty samples of zirconia were subjected to the four-surface treatment protocols (sandblasting, 48% hydrofluoric acid (HF), 48% hydrofluoric acid + 70% nitric acid (HNO3) and no treatment (control) following which the samples from each group were subdivided into two subgroups (n = 10) based on the resin cement employed for cementation (RelyX U200 and G-Cem Linkforce). The bonded specimens were subjected to shear stress to measure the bond strength using Universal testing machine. To test the difference in bond strength among the eight study groups, the Kruskal-Wallis ANOVA test was applied and for comparison between cements in each group, Mann-Whitney U test was applied. RESULTS: The highest bond strength values were observed for 48% HF group cemented with G-Cem Linkforce resin cement (16.220 ± 1.574) and lowest for control group-RelyX (4.954 ± 0.972). G-Cem cement showed higher bond strength than RelyX for all surface treatments except 48% HF + 70% nitric acid. CONCLUSION: It can be inferred that 48% HF can etch zirconia and generate a porous structure that proves to be beneficial for bonding. CLINICAL SIGNIFICANCE: The increasing demand for esthetics has led to the replacement of metal-ceramic materials with zirconia-based ceramics. However, the chemical inertness of zirconia to various conventional surface treating agents has continuously challenged researchers to discover a new surface treatment protocol that could enhance the bond strength of zirconia. How to cite this article: Yenamandra MS, Joseph A, Singh P, et al. Effect of Various Surface Treatments of Zirconia on its Adhesive Properties to Dentin: An In Vitro Study. J Contemp Dent Pract 2024;25(3):226-230.


Assuntos
Colagem Dentária , Dentina , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Zircônio , Cimentos de Resina/química , Colagem Dentária/métodos , Técnicas In Vitro , Humanos , Análise do Estresse Dentário , Resistência ao Cisalhamento , Ácido Fluorídrico/química , Ácido Nítrico/química , Cerâmica/química
4.
Eur J Prosthodont Restor Dent ; 32(1): 28-44, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-37463022

RESUMO

INTRODUCTION: This systematic review examined the effect of neutralizing agents on bond strength after irrigation with sodium hypochlorite and their existing protocols in literature. METHODS: This present study adhered to the PRISMA guidelines and was registered at PROSPERO. Five electronic databases were searched (sept-2020/jan-2021) in English, Spanish, and Portuguese, without any restrictions on publication date. Cases reports, editorials and literature reviews were not included. The risk of bias was assessed using the Cochrane Collaboration tool. From the initial 7,147 studies, 2,745 were removed as duplicates and 4,382 were excluded after a title/abstract screen. RESULTS: Seventeen in vitro studies were included. The results showed that the higher the concentration of sodium hypochlorite, the lower the bond strength at dentine/restoration interface (p⟨0.01). Among the studies, sodium ascorbate was the most widely used neutralizer and showed the most significant results in increasing bond strength (p⟨0.01). The bond strength values were found to increase with longer application time of the neutralizing substances (p⟨0.01). CONCLUSIONS: The use of sodium ascorbate as a neutralizing agent can reverse the negative effects of the sodium hypochlorite and improve the bond strength between dentine and resin cement, however, it isn't possible to determine the best protocol for use.


Assuntos
Colagem Dentária , Hipoclorito de Sódio/química , Hipoclorito de Sódio/farmacologia , Cimentos de Resina/química , Ácido Ascórbico/química , Ácido Ascórbico/farmacologia , Dentina , Teste de Materiais
5.
Eur J Prosthodont Restor Dent ; 32(1): 83-90, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-37814894

RESUMO

INTRODUCTION: The degree of conversion (DC) of resin cements can be affected by ceramics, and by the type of resin cement. The purpose was to evaluate the influence of thickness and translucencies of lithium disilicate ceramic on the DC of resin cements: two light-cure (Variolink LC; NX3 LC) and one dual-cure (NX3 Dual). METHODS: IPS e.max Press ceramic (A2) discs were prepared in 4 thicknesses (0.3, 0.5, 1.0, and 1.5 mm) and in 3 translucencies: HT (high translucency), LT (low translucency), and MO (medium opacity). Subsequently, 234 samples of resin cement (5 x 1 mm) were light-cured through those ceramic discs. The DC was assessed by Fourier Transform Infrared Spectroscopy (FTIR). RESULTS: Ceramic thicknesses decreased DC of NX3 Dual through HT-1.0 and HT 1.5 (p=0.005). Between translucencies, only MO-0.3 affected Variolink LC DC (p=0.018). There was difference among light- and dual-cured resin cements (p=0.001). CONCLUSION: Increasing thickness and opacity lead to a decrease in the DC of all resin cements, with a significantly lower DC value in NX3 Dual (HT-1.0; HT-1.5), and in Variolink LC (MO- 0.3). Light- and dual-cured resin cements were different among each other. NX3 Dual achieved a significantly lower value than its counterpart NX3 LC.


Assuntos
Porcelana Dentária , Cimentos de Resina , Cimentos de Resina/química , Teste de Materiais , Porcelana Dentária/química , Cerâmica/química , Espectroscopia de Infravermelho com Transformada de Fourier
6.
Eur J Oral Sci ; 131(2): e12926, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36792368

RESUMO

This study intended to evaluate the effect of digital veneering on four-point flexural strength (FS) and microtensile bond strength (µTBS) of veneered zirconia. Two different zirconia blocks, a lithium disilicate and a feldspathic ceramic block, and two different layering ceramics were used. IPS e.max Zir CAD (ZC) and Vita In-Ceram YZ (YZ) with yttria stabilized tetragonal zirconia polycrystals (3Y-TZP) were used as substructures. IPS e.max CAD (LD), Vita Mark II (VMII), IPS e.max Ceram (EC) and Vita VM9 (VM9) were used for veneering. Resin cement and fusion ceramic were placed between veneer and zirconia substructure for digital veneering. A total of one hundred and fifty specimens in five groups (n = 30) were prepared for FS and tested in universal machine at 1.0 mm/min. One hundred specimens in five groups (n = 20) were obtained for the µTBS and tested at 1.0 mm/min. Statistical analysis was made by one way ANOVA and Tukey HSD. Conventional veneering showed statistically significant FS. ZC veneered with EC had the highest mean FS and the lowest was obtained in groups veneered through resin cement. YZ layered with VM9 had the highest mean µTBS. ZC veneered through fusion ceramic and YZ veneered through resin cement showed significantly lower and similar µTBS.


Assuntos
Colagem Dentária , Resistência à Flexão , Cimentos de Resina , Teste de Materiais , Análise do Estresse Dentário , Propriedades de Superfície , Porcelana Dentária/química , Cerâmica , Zircônio/química , Facetas Dentárias
7.
Clin Oral Investig ; 27(12): 7833-7840, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37989965

RESUMO

OBJECTIVES: To assess the effect of glass-ceramic coated zirconia versus alumina air-abraded zirconia on the shear bond strength (SBS) of resin cement and investigate the residual stresses present on both mechanically pre-treated surfaces. MATERIALS AND METHODS: A total of 180 zirconia disks, with diameters of 10 mm and 5 mm, were divided into two groups: DCMhotbond glass-ceramic coated, followed by hydrofluoric acid etching (DCM), and alumina air-abraded (AB). All mechanically pre-treated disks were conditioned with G-Multi Primer and bonded using G-Cem Linkforce Cement. Ninety specimens were immersed in distilled water for 24 h and subsequently allocated into three groups based on aging conditions (n = 15/subgroups): immediate testing, 5000 thermal cycles, and 10,000 thermal cycles. Then, the shear bond strength was assessed, and the obtained data were subjected to analysis using a two-way ANOVA, followed by a one-way ANOVA and Tukey's HSD post hoc test (α = 0.05). The residual stresses present on both mechanically pre-treated surfaces were examined using X-ray diffraction analysis. RESULTS: The mean SBS values of the DCM and AB groups showed no significant difference under each aging condition. The SBS of DCM groups was not affected by thermal cycles, whereas the SBS of AB groups exhibited a significant decrease following thermal cycles. Glass-ceramic coated surfaces exhibited higher compressive stresses than alumina air-abrasion. CONCLUSIONS: The DCMhotbond glass-ceramic coated zirconia showed comparable bond strength to the alumina air-abrasion technique. CLINICAL RELEVANCE: The DCMhotbond glass-ceramic coating technique is a promising alternative for zirconia surface pre-treatment. However, further investigations are needed before suggesting its clinical use.


Assuntos
Colagem Dentária , Óxido de Alumínio/química , Propriedades de Superfície , Cerâmica/química , Cimentos de Resina/química , Zircônio/química , Resistência ao Cisalhamento , Teste de Materiais , Análise do Estresse Dentário
8.
Clin Oral Investig ; 27(8): 4379-4387, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37162571

RESUMO

OBJECTIVES: This study aims to investigate the load-to-fracture of procedures changing crown-to-root ratio (RCRR) aimed to restore severely damaged upper central incisors to avoid tooth extraction compared to implant placement. There is no evidence on load capability after apical root resection (AR), orthodontic extrusion (OE), and surgical crown lengthening (SCL) in respect to RCRR, respectively. MATERIAL AND METHODS: Human maxillary central incisors were endodontically treated, decoronated, and divided into 4 groups (n = 48). The following specimen preparation was performed: (I) adhesive core-and-post build-up (control), (II) as (I) and 2 mm apical root resection (AR), (III) before adhesive core-and-post build-up teeth were shortened 2 mm coronally (OE) (IV) as (I), but specimens were embedded 4 mm instead of 2 mm below the CEJ (SCL), group (V) implant-borne restoration with individual all-ceramic abutments (n = 12; ∅4.1/l = 12 mm) (IBR). All specimens received all-ceramic crowns, thermo-mechanical (TML), and subsequent linear loading (LL) until failure. RCRR were calculated and log-rank, Kruskal-Wallis, Mann-Whitney U, ANOVA, and chi-square tests applied (p = 0.05). RESULTS: Fracture loads after subsequent LL differed significantly (p = 0.001) between groups, while implants showed the highest values. Fmax median (min/max) were as follows: (I) 252 (204/542), (II) 293 (243/443), (III) 253 (183/371), (IV) 195 (140/274), and (V) 446 (370/539). Pair-wise comparison showed significant differences (p = 0.001) between group I/IV and group V, I, and IV (p = 0.045), II and IV (p = 0.001), and III compared to IV (p = 0.033), respectively. RCRR below 1 significantly increased load capability compared to RCRR = 1. CONCLUSIONS: OE appears to preferably ensure biomechanical stability of teeth that are endodontically treated and receive core-and-post and crown placement compared to SCL. AR has no adverse biomechanical impact. RCRR < 1 is biomechanically beneficial. CLINICAL RELEVANCE: For endodontically treated and restored teeth, orthodontic extrusion should be preferred compared to surgical crown lengthening prior single-crown restoration. As orthodontic extrusion, apical root resection has no adverse effect on load capability. Single-crown implant-borne restorations are most load capable.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Humanos , Extrusão Ortodôntica/efeitos adversos , Aumento da Coroa Clínica/efeitos adversos , Resinas Compostas , Dente não Vital/cirurgia , Coroas , Fraturas dos Dentes/cirurgia , Análise do Estresse Dentário , Falha de Restauração Dentária
9.
BMC Oral Health ; 23(1): 636, 2023 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-37670286

RESUMO

OBJECTIVES: Successful ceramic restorations depend on the strong bonding with resin cement and even stress distribution. The aim of this study was to evaluate the impact of adding MDP-containing zirconia primer before self-adhesive resin cements with different functional acidic monomers on fracture resistance of monolithic zirconia crown. MATERIALS AND METHODS: Eighty defect-free human maxillary premolars were divided according to the cement type and application of MDP-containing zirconia primer into eight groups (n = 10): Calibra Universal (C), Calibra Universal combined with zirconia primer (CZ), RelyX U200 (R), RelyXU200 combined with zirconia primer (RZ), Panavia SA Cement Plus (P), Panavia SA Cement Plus combined with zirconia primer (PZ), Multilink Speed (M), and Multilink Speed combined with zirconia primer (MZ). After teeth preparation and fabrication of zirconia crowns, each crown was bonded to its corresponding tooth. All specimens were subjected to 10,000 thermocycles between 5 and 55°C, followed by cyclic load (50 N) for 240,000 cycles. Each specimen was subjected to a static axial load until fracture using universal testing machine and the fracture load was recorded. The fracture mode studied and recorded. The fracture load results were analyzed using two-way ANOVA test (α = 0.05). RESULTS: A significant interaction (P = 0.038) of combining MDP-containing zirconia primer and cement type on fracture resistance of monolithic zirconia crown was detected. The mean fracture load values of zirconia crown were significantly influenced by the combined application of the MDP-containing zirconia primer with Calibra Universal (P = 0.01), RelyX U200 (P < 0.001), and Multilink Speed (P = 0.038), while there was no significant difference with Panavia SA Cement Plus (P = 0.660). There was significant difference (F = 20.69, P < 0.001) between the mean fracture loads of groups with self-adhesive cements (C, R, P, and M groups). The highest fracture load was recorded with RZ group (2446.90 ± 126.72 N) while the lowest fracture load was recorded with C group (1623.18 ± 149.86 N). CONCLUSIONS: The self-adhesive resin cement with different acidic functional monomer affects the fracture resistance of monolithic zirconia crown. Application of MDP-containing primer could improve the fracture resistance of monolithic zirconia crown with most self-adhesive cements. The application of an MDP-containing primer had no impact on the fracture resistance of monolithic translucent zirconia crown bonded by MDP-containing self-adhesive resin cement.


Assuntos
Cimentos Dentários , Cimentos de Resina , Humanos , Cemento Dentário , Cimentos de Ionômeros de Vidro , Coroas
10.
Medicina (Kaunas) ; 59(10)2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37893515

RESUMO

Background and Objectives: Although fiber posts are widely used in the restoration of endodontically treated teeth (ETT), their ideal cementation depth into the root canal is still debated in literature. The aim of the present study was to evaluate whether the different intra-radicular insertion lengths of the fiber posts influence the fracture strength of ETT. Materials and Methods: A total of 10 permanent human lower incisors with straight roots of similar length and volume extracted for periodontal reason were sectioned 2 mm above the cement-enamel junction (CEJ) to a total length of 18 mm and endodontically treated in the same manner, then randomly divided into two groups of five each (Groups 1 and 2, n = 5). Two sound incisors, with no endodontic treatment, were used as the control group (Group 3, n = 2). After one week of storage in a humid environment, spaces for fiber post no. 1 (Reforpost, Angelus, Londrina, PR, Brazil) were prepared in the first two groups at a depth of 5 mm (Group 1) and 7 mm (Group 2), and the fiber posts were adhesively cemented using self-adhesive resin cement (Maxcem Elite, Kerr GmbH, Herzogenrath, Germany). After 7 days, the samples were vertically positioned and fixed in a self-curing transparent acrylic resin, up to 2 mm below the CEJ level, and mechanically tested in compression after another week of storage using a displacement-controlled testing machine up to each sample's fracture. The force-displacement curves were recorded for each sample, the means were calculated for each group and a statistical comparative analysis between groups was conducted. Results: Although no statistically significant differences between groups were observed, the highest mean fracture force (N) was recorded in Group 2 (1099.41 ± 481.89) in comparison to Group 1 (985.09 ± 330.28), even when compared to the sound, non-treated teeth (1045.69 ± 146.19). Conclusions: Within the limitations of this in vitro study, teeth where fiber posts were placed deeper into the root canal (7 mm) recorded slightly higher fracture forces in comparison with shorter lengths (5 mm). However, similar biomechanical performances obtained in the mechanical tests showed no statistical differences between the 7 mm and the 5 mm inserted posts.


Assuntos
Fraturas dos Dentes , Dente não Vital , Humanos , Resistência à Flexão , Resinas Compostas , Dente não Vital/terapia , Incisivo
11.
J Contemp Dent Pract ; 24(10): 725-728, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38152902

RESUMO

AIM: The purpose of this study was to evaluate the bond strength and fracture mode of universal resin cement to dentin compared to self-adhesive and adhesive resin cement with and without an adhesive bonding agent. MATERIALS AND METHODS: Seventy-two molar teeth were sectioned to expose coronal dentin, divided into three groups, and assigned to RelyX Universal (universal), RelyX Ultimate (adhesive), or RelyX Unicem 2 (self-adhesive) cements from 3M. The 3 groups were further subdivided into 2 subgroups of 12 specimens each, with or without the use of an adhesive bonding agent. Lithium-disilicate discs were bonded to the dentin surface using the cements, stored for 24 hours in distilled water, and subjected to 2,000 thermocycles before shear bond strength testing and fracture mode analysis. RESULTS: Significant differences in bond strength and fracture mode were found between groups based on cement or the use of a bonding agent. Both the universal and adhesive cements had significantly greater bond strengths to dentin with the use of a bonding agent versus no bonding agent. With the self-adhesive cement, there was no significant increase in bond strength to dentin with the use of a bonding agent. CONCLUSION: The novel universal resin cement had similar bond strengths to dentin as the adhesive cement with the use of a bonding agent, and similar bond strengths as the self-adhesive cement without the use of a bonding agent. The adhesively bonded universal cement had the greatest percentage of mixed and cohesive fractures. CLINICAL SIGNIFICANCE: When greater adhesion is needed clinically, the novel universal resin cement may be used with an adhesive bonding agent. However, when less adhesion is needed, it could be used without a bonding agent in self-adhesive mode.


Assuntos
Colagem Dentária , Cimentos de Resina , Cimentos de Resina/química , Cimentos Dentários/química , Cimentos de Ionômeros de Vidro/química , Dentina , Teste de Materiais , Análise do Estresse Dentário , Adesivos Dentinários/química , Propriedades de Superfície , Resistência ao Cisalhamento
12.
J Contemp Dent Pract ; 24(11): 859-863, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-38238273

RESUMO

AIM: To compare the bond strength of two resin cements to leucite-reinforced ceramics using three different boding agents and evaluate the compatibility of bonding agents. MATERIALS AND METHODS: Twenty extracted sound human molars were sectioned horizontally 2-3 mm above the cementoenamel junction (CEJ). CAD/CAM ceramic blocks for inLab were also sectioned to create 4 mm thick and bonded to the dentin. The adhesive groups assigned were divided into four adhesive groups: Group I: Variolink II dual-cure resin cement and Scotchbond Multi-Purpose Plus adhesive, group II: Multilink Automix dual-cure resin cement and Multilink primers, group III: Multilink Automix and Clearfil SE bond 2 (CSE2) adhesive, group IV: Multilink Automix and CSE2 with light curing after adhesive application. Five specimens of each group were sectioned perpendicular to obtain six microsticks of 1 × 1 mm width from each sample. Microtensile bond strength data were expressed in MPa. Fracture modes (FrMs) analyzed for the surfaces were divided into six patterns. Microtensile bond strength data were statistically analyzed with one-way ANOVA and Tukey post hoc tests (α = 0.05). T-test was performed at the 5% significance level to analyze groups III and IV with and without light curing. RESULTS: Group I showed the highest µTBS average of 13.67 MPa, group IV showed 12.26 MPa, group III showed 12.15 MPa, and group II showed the lowest average of 10.84 MPa. No significant differences were found between the bonding agents. However, the six types of failure modes, although all observed, were characterized by the adhesive system: Type I: adhesive failure of laminated dentin and ceramic; type II: adhesive failure of laminated ceramic; type III: adhesive failure of laminated dentin; type IV: cohesive failure of luting agent; type V: cohesive failure of dentin, and type VI: mixed failure of adhesion and cohesion. As a result, the FrM most commonly observed was the adhesive failure at the luting cement-ceramic block interface. CONCLUSION: The combination of resin cements and bonding agents did not significantly affect the bond strength of CAD/CAM ceramic restorations and dentin. CLINICAL SIGNIFICANCE: Several universal bonding agents are currently available for direct and indirect bonding, and using the same bonding agent for direct and indirect restorations could simplify inventory and benefit routine clinical practice. How to cite this article: Aida N, Koi K, Amaya-Pajares SP, et al. Bond Strength of Two Resin Cements with Leucite-reinforced Ceramic Using Different Bonding Agents. J Contemp Dent Pract 2023;24(11):859-863.


Assuntos
Silicatos de Alumínio , Colagem Dentária , Cimentos de Resina , Humanos , Cimentos de Resina/química , Porcelana Dentária/química , Propriedades de Superfície , Cerâmica/química , Cimentos Dentários/química , Teste de Materiais , Resistência à Tração , Adesivos Dentinários/química
13.
Int Endod J ; 55(9): 950-963, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35768890

RESUMO

AIM: The aim of the study was to investigate the influence of cavity cleaning and conditioning on marginal integrity of directly placed post-endodontic composite class-I-restorations in vitro. METHODOLOGY: A total of 168 fully intact teeth without caries or fillings received pre-endodontic composite restorations (class-II) after their extraction. Occlusal endodontic access-cavities were prepared, and root canals were instrumented and filled with gutta-percha and an epoxy resin-based sealer. Prior to post-endodontic class-I-restoration, access cavities were completely contaminated with sealer, cleaned with alcohol and pre-treated as follows: cleaner only (alcohol), glycine-polishing, Al2 O3 sandblasting, carbide bur (immediate as well as delayed restoration). A positive control (not contaminated with sealer and adhesive used) and negative control (cleaner used but no adhesive) were established. Half of the teeth from each group were subjected to thermocycling and mechanical loading (TCML). Marginal integrity of post-endodontic restoration was evaluated in oro-vestibular or mesio-distal sections after AgNO3 dye penetration (DP) by standardized photomacroscopic imaging and expressed in per cent of margin length along all segments and separately for enamel, dentine and composite, respectively. Results were analysed non-parametrically (α = .05). RESULTS: No restorations or teeth fractured or debonded completely. Without TCML, the median DP of all segments was significantly higher for the negative control compared with all other groups in oro-vestibular cutting direction (53%; p = .002) and in mesio-distal cutting direction (51%; p ≤ .041). The other groups without TCML revealed 16%-24% DP (oro-vestibular) and 12%-24% DP (mesio-distal). With TCML, the median DP in oro-vestibular cutting direction for all segments ranged between 48% and 62% for all groups, a significant difference was only observed between glycine-polishing and carbide bur (p = .041). In mesio-distal cutting direction, the median DP in negative control was 69% with TCML and significantly higher compared with all other groups (p = .002). For all other groups, the median DP of all segments ranged between 28% and 40% with TCML without significant differences. Error rates method (k = 7) revealed a significant influence of TCML in general on penetration of all segments in both oro-vestibular and mesio-distal cutting directions. CONCLUSION: Additional access cavity pre-treatment after alcohol cleaning did not improve the marginal integrity of post-endodontic composite restorations. Thorough cleaning of the access cavity with alcohol seems to assure an acceptable marginal integrity to the tooth and restorative composite.


Assuntos
Infiltração Dentária , Restauração Dentária Permanente , Resinas Compostas , Preparo da Cavidade Dentária/métodos , Infiltração Dentária/prevenção & controle , Adaptação Marginal Dentária , Restauração Dentária Permanente/métodos , Glicina , Humanos , Teste de Materiais , Cimentos de Resina
14.
J Esthet Restor Dent ; 34(7): 1051-1059, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35644927

RESUMO

OBJECTIVES: To evaluate the influence of dentin pretreatments on the push-out bond strength (POBS) of self-adhesive resin cements (SARCs) to radicular dentin. MATERIALS AND METHODS: Two experimental pretreatments (2.5% titanium tetrafluoride (TiF4 ) and 26% polyacrylic acid (PA)) and two SARCs: Maxcem Elite (MAX) and Calibra Universal (CAL) were used. For each cement, a control group was applied as indicated by the manufacturer. Sixty bovine incisors were restored (n = 10) and subjected to POBS evaluation. Failure mode, adhesive interface and surface morphology were analyzed by a Scanning Electron Microscopy (SEM) and resin infiltration was performed by confocal laser scanning microscopy (CLSM). Data for POBS and CLSM were analyzed by three-way ANOVA and Bonferroni post-hoc (α = 0.05). RESULTS: For MAX, both experimental pretreatments resulted in increased POBS in the cervical third, and for CAL, only the PA resulted in higher POBS in the cervical third. The most failures occurred between the dentin and the resin cement, except when TiF4 was applied. For PA, analysis of surface morphology showed open dentinal tubules, while TiF4 presented particle agglomerates. SEM and CLSM images confirmed presence of resin tags for both pretreatments. CONCLUSION: Pretreating radicular dentin with PA and TiF4 solutions improves the bond strength of SARCs.


Assuntos
Colagem Dentária , Cimentos de Resina , Animais , Bovinos , Colagem Dentária/métodos , Cimentos Dentários/química , Análise do Estresse Dentário , Dentina , Adesivos Dentinários/química , Teste de Materiais , Cimentos de Resina/química , Propriedades de Superfície
15.
J Esthet Restor Dent ; 34(1): 117-135, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35072329

RESUMO

OBJECTIVES: Several systematic literature reviews have assessed the scientific evidence on resin bonding protocols to conventional 3 mol% ytrria-stabilized zirconia (3Y-TZP) ceramics. It has been widely discussed, however, that the differing composition and physical properties of new high-translucent zirconia generations (4Y-TZP and 5Y-TZP) may require alternative bonding materials and procedures. This paper reviewed in vitro studies on the success and durability of bonding protocols to high-translucent zirconia. MATERIAL AND METHODS: A systematic search of PubMed and Cochrane Library for in vitro studies on bonding to new zirconia generations published until November 2020 was conducted and complemented by a manual search. Studies selected for review fulfilled the applied inclusion and exclusion criteria. The quality of the included studies was assessed with the Cochrane risk-of-bias tool for randomized trials. RESULTS: Of 629 screened articles, 18 were included in this review. They investigated different surface pretreatment methods, primers, resin cements, aging procedures, and bond strength test protocols. The limited number of the identified studies and the heterogeneity of the extracted data did not allow to conduct a meta-analysis. CONCLUSIONS: The available evidence suggests that resin bonding protocols successfully applied to conventional zirconia are also the most successful for high-translucent zirconia. Airborne particle abrasion and special phosphate monomer-containing primers or composite resin cements provide long-term durable resin bonds. CLINICAL SIGNIFICANCE: Durable bonds can be established between high-translucent zirconia and resin cements. The bonding materials and procedures applied do not compromise their physical properties.


Assuntos
Colagem Dentária , Cerâmica/química , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina/química , Propriedades de Superfície , Zircônio/química
16.
J Esthet Restor Dent ; 34(4): 641-649, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34897958

RESUMO

OBJECTIVE: This study aims to evaluate and compare the film thickness obtained with a resin cement and two composite resins, preheated and/or ultrasonically vibrated, as luting agents. MATERIALS AND METHODS: One hundred and twenty-six (126) pairs of resin discs were randomly assigned to six experimental groups (n = 21) according to luting agent (Variolink Esthetic LC, IPS Empress Direct or Estelite Omega) and cementation technique (preheating at 68°C and/or ultrasonic vibration). Specimens were luted by applying a controlled force. Following sectioning and film thickness measurement through field emission gun scanning electron microscopy, statistical analysis was carried out considering a 5% significance level. RESULTS: Statistically significant lower film thickness was observed in Variolink Esthetic LC group when compared to all composite resin groups (p < 0.001), except IPS Empress Direct preheated and ultrasonically vibrated group (p = 0.073). IPS Empress Direct with ultrasonic vibration yielded statistically lower film thickness values than Estelite Omega groups, regardless of luting technique (p < 0.05). Ultrasonically vibrated Estelite Omega groups showed statistically lower film thickness values than solely preheated groups (p < 0.05). CONCLUSIONS: Both Variolink Esthetic LC and IPS Empress Direct preheated and ultrasonically vibrated provided the lowest film thickness. The addition of ultrasonic vibration during cementation proved to be effective in reducing film thickness of both tested composite resins. CLINICAL SIGNIFICANCE: The cementation technique will have variable results depending on the luting material. Adhesive cementation protocols with composite resins should mainly consider ultrasonic vibration, but also preheating, as strategies for reducing film thickness. The tested resin cement, alongside with IPS Empress Direct composite resin preheated and ultrasonically vibrated, provided the lowest film thickness among the tested materials and techniques.


Assuntos
Colagem Dentária , Cimentos de Resina , Cimentação , Resinas Compostas , Colagem Dentária/métodos , Cimentos Dentários , Porcelana Dentária , Teste de Materiais , Propriedades de Superfície
17.
J Contemp Dent Pract ; 23(5): 539-542, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35986463

RESUMO

AIM: Aim of this study was to assess the thermal changes within the pulp at the time of polymerization of three different adhesive resin materials. MATERIALS AND METHODS: Sixty human premolar teeth that had been recently extracted for orthodontic reasons and were devoid of dental caries/flaws were included in this research. Following preparation of the cavities, all 60 samples consisting of 20 premolars in every group, depending on the adhesive resins that were positioned as were assigned at random to one of the following three groups: Group I: RelyX self-adhesive resin cement; Group II: Breeze self-adhesive resin cement; Group III: Pan F self-etch adhesive resin cement. The temperature changes were calculated using a thermocouple wire attached to a digital thermometer. The dissimilarities amid the baseline temperature as well as the temperatures at different time intervals (1, 5, 10, and 15 minutes) were established. RESULTS: The thermal value was higher at first minute (1.84 ± 0.34) and gradually reduced at 5 minutes (1.36 ± 0.29), 10 minutes (0.62 ± 0.11), and 15 minutes (0.06 ± 0.03) in RelyX self-adhesive resin cement. The maximum thermal value was found at the first minute (2.66 ± 0.21) and gradually reduced at 5 minutes (1.42 ± 0.13), 10 minutes (0.86 ± 0.09), and 15 minutes (0.28 ± 0.01) in Breeze self-adhesive resin cement. The higher thermal value was found at the first minute (1.98 ± 0.19) and gradually reduced at 5 minutes (1.49 ± 0.14), 10 minutes (0.76 ± 0.10), and 15 minutes (0.16 ± 0.09) in Pan F self-etch adhesive resin cement and there was a statistically significant difference found between various time points and with all three adhesive resin material groups (p <0.001). CONCLUSION: This current research arrived at a conclusion that each of the three adhesive resin substances showed a safe temperature change within the pulp. However, the lowest heat scores within the pulp were depicted by RelyX self-adhesive resin in pursuit by Pan F self-etch adhesive resin cement as well as the Breeze self-adhesive resin cement in that order. CLINICAL SIGNIFICANCE: The clinical triumph of a restoration is dependent partially on the method of cementation, which is utilized to establish a connection amid the restoration and the tooth. Temporary and permanent pulp inflammation can be avoided by the decreased temperature changes in the adhesive resin cement at the time of polymerization.


Assuntos
Colagem Dentária , Cárie Dentária , Resinas Compostas/química , Colagem Dentária/métodos , Cimentos Dentários/química , Análise do Estresse Dentário , Humanos , Teste de Materiais , Polimerização , Cimentos de Resina/química
18.
J Contemp Dent Pract ; 23(4): 388-392, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35945830

RESUMO

AIM: To assess dentin-post bond strength and mode of failure through tensile strength testing of two endodontic post systems: CAD/CAM custom-milled fiber posts vs Splendor SAP. MATERIALS AND METHODS: Thirty extracted single-rooted mandibular premolars were sectioned 2 mm coronal to the cementoenamel junction. Root length was standardized at 15 mm, and the root canals were instrumented with #20 K-files followed by 30/0.03 and 30/0.05 ProDesign Logic rotary files, under irrigation with 2.5% NaOCl, and then submitted to final irrigation with 17% EDTA. Canals were filled with gutta-percha and AH PLUS sealer. After 24 hours, the teeth were prepared for post placement to a depth of 10 mm and randomly allocated into two experimental groups (n = 15): CAD/CAM (CC) and Splendor SAP (SS). All posts were cemented with RelyX U200 dual-cure self-adhesive resin cement. The roots were embedded in acrylic resin, and the specimens were stored for 7 days in moist heat (37°C). Tensile strength testing until failure was then performed in a universal testing machine using a crosshead speed of 0.5 mm/minute. The final failure load was tabulated for statistical analysis, and the G test was used to compare the failure modes observed under light microscopy (5× magnification). RESULTS: There was no significant difference between groups regarding tensile bond strength to root dentin (p = 0.325). Conversely, failure mode differed significantly between groups (p = 0.037). CONCLUSION: The tensile bond strength observed for the CAD/CAM and Splendor SAP post systems was similar. Adhesive failure was predominant in both groups; however, the CAD/CAM custom-milled fiber posts failed predominantly at the dentin-resin cement interface, whereas Splendor SAP posts failed mostly at the post-resin cement interface. CLINICAL SIGNIFICANCE: A strong post-dentin bond is a key to the success of dental restorations and prosthetic rehabilitation. In teeth with severe coronal decay and wide canals, both of the tested systems would be able to achieve good cervical fit.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Desenho Assistido por Computador , Cavidade Pulpar , Análise do Estresse Dentário , Dentina , Teste de Materiais , Cimentos de Resina/química
19.
Eur J Prosthodont Restor Dent ; 30(3): 230-238, 2022 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-34982861

RESUMO

PURPOSE/AIM: To determine the effect of translucency of four CAD/CAM materials and different curing modes on the degree of conversion of resin cements. MATERIALS AND METHODS: Disks were fabricated from IPS e.max CAD, Vita Suprinity, Vita Enamic, and DD Cube X². Translucency was measured using a spectrophotometer. The degree of conversion of two resin cements Variolink Esthetic DC and LC were measured using a Fourier transform infrared spectrometer. For Esthetic DC, the degree of conversion was determined in self-cure and dual cure modes. ANOVA, Tukey HSD test, and /Linear Regression R2 were used to statistically analyze the data. RESULTS: There was a significant difference in the translucency of the four materials (P ⟨ 0.0001). The mean translucency of Vita Suprinity was significantly higher, followed by Vita Enamic, DD Cube X², and IPS E.max CAD. Degree of conversion of resin cements cured under DD Cube X² had the highest values (25.22%), whereas those cured under Vita Suprinity showed the lowest values (17.86%). The self-cure mode had the lowest degree of conversion values (16.22%) and dual cure mode showed the highest values (26.12%). A negative linear relationship was found between degree of conversion and translucency of the CAD/CAM materials.


Assuntos
Cerâmica , Cimentos de Resina , Desenho Assistido por Computador , Teste de Materiais , Polimerização , Propriedades de Superfície
20.
Eur J Oral Sci ; 129(4): e12791, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34057757

RESUMO

The purpose of the study was to measure the cement thickness obtained when ceramic rods were luted to dentin and to analyze the relation between cement thickness and the previously published tensile bond strength of similar test specimens. In addition, the ISO standard 4049:2019 method was used to determine the film thickness of the used cements. Zirconia (n = 100) and lithium disilicate (n = 50) rods were cemented to bovine dentin using one of five different resin-based cements. The ceramic-dentin test specimens were cut into two slices and the cement thickness was measured using a scanning electron microscope and compared to the bond strength values of similar specimens already published. The mean cement thickness recorded for ceramic rods cemented to dentin was in the range 20-40 µm, which was larger than the cement film thickness found by the ISO method. The cement film thickness determined according to ISO standard methods did not concur with the results obtained when cementing ceramic rods to dentin. For cementing ceramic restorations, a cement thickness in the range 25-35 µm seems to be favorable for the bond strength.


Assuntos
Colagem Dentária , Cimentos de Resina , Animais , Bovinos , Cerâmica , Porcelana Dentária , Dentina , Teste de Materiais , Propriedades de Superfície , Resistência à Tração , Zircônio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA