Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.047
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Osteoporos Int ; 35(10): 1767-1772, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38900164

RESUMO

Patients who sustain fragility fractures prior to total shoulder arthroplasty have significantly higher risk for bone health-related complications within 8 years of procedure. Identification of these high-risk patients with an emphasis on preoperative, intraoperative, and postoperative bone health optimization may help minimize these preventable complications. PURPOSE: As the population ages, more patients with osteoporosis are undergoing total shoulder arthroplasty (TSA), including those who have sustained a prior fragility fracture. Sustaining a fragility fracture before TSA has been associated with increased risk of short-term revision rates, periprosthetic fracture (PPF), and secondary fragility fractures but long-term implant survivorship in this patient population is unknown. Therefore, the purpose of this study was to characterize the association of prior fragility fractures with 8-year risks of revision TSA, periprosthetic fracture, and secondary fragility fracture. METHODS: Patients aged 50 years and older who underwent TSA were identified in a large national database. Patients were stratified based on whether they sustained a fragility fracture within 3 years prior to TSA. Patients who had a prior fragility fracture (7631) were matched 1:1 to patients who did not based on age, gender, Charlson Comorbidity Index (CCI), smoking, obesity, diabetes mellitus, and alcohol use. Kaplan-Meier and Cox Proportional Hazards analyses were used to observe the cumulative incidences of all-cause revision, periprosthetic fracture, and secondary fragility fracture within 8 years of index surgery. RESULTS: The 8-year cumulative incidence of revision TSA (5.7% vs. 4.1%), periprosthetic fracture (3.8% vs. 1.4%), and secondary fragility fracture (46.5% vs. 10.1%) were significantly higher for those who had a prior fragility fracture when compared to those who did not. On multivariable analysis, a prior fragility fracture was associated with higher risks of revision (hazard ratio [HR], 1.48; 95% confidence interval [CI], 1.24-1.74; p < 0.001), periprosthetic fracture (HR, 2.98; 95% CI, 2.18-4.07; p < 0.001) and secondary fragility fracture (HR, 8.39; 95% CI, 7.62-9.24; p < 0.001). CONCLUSIONS: Prior fragility fracture was a significant risk factor for revision, periprosthetic fracture, and secondary fragility fracture within 8 years of primary TSA. Identification of these high-risk patients with an emphasis on preoperative and postoperative bone health optimization may help minimize these complications. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Ombro , Fraturas por Osteoporose , Fraturas Periprotéticas , Reoperação , Humanos , Feminino , Idoso , Masculino , Artroplastia do Ombro/efeitos adversos , Pessoa de Meia-Idade , Fraturas por Osteoporose/epidemiologia , Fraturas por Osteoporose/etiologia , Fraturas por Osteoporose/cirurgia , Reoperação/estatística & dados numéricos , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Idoso de 80 Anos ou mais , Medição de Risco/métodos , Fatores de Risco , Recidiva , Bases de Dados Factuais
2.
J Ultrasound Med ; 43(2): 375-383, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37987527

RESUMO

OBJECTIVES: A new ultrasound-based device is proposed to non-invasively measure the orientation of the scapula in the standing position to consider this parameter for Total Shoulder Arthroplasty. The aim of this study was to assess the accuracy and reliability of this device. METHODS: Accuracy was assessed by comparing measurements made with the ultrasound device to those acquired with a three-dimensional (3D) optical localization system (Northern Digital, Canada) on a dedicated mechanical phantom. Three users performed 10 measurements on three healthy volunteers with different body mass (BMI) indices to analyze the reliability of the device by measuring the intra and interobserver variabilities. RESULTS: The mean accuracy of the device was 0.9°± 0.7 (0.01-3.03), 1.3°± 0.8 (0.03-4.55), 1.9°± 1.5 (0.05-5.76), respectively, in the axial, coronal, and sagittal planes. The interobserver and intraobserver variabilities were excellent whatever the BMI and the users experience. CONCLUSIONS: The device is accurate and reliable enough for the measurement of the scapula orientation in the standing position.


Assuntos
Articulação do Ombro , Posição Ortostática , Humanos , Reprodutibilidade dos Testes , Escápula/diagnóstico por imagem , Variações Dependentes do Observador , Canadá , Articulação do Ombro/diagnóstico por imagem , Amplitude de Movimento Articular , Fenômenos Biomecânicos
3.
BMC Musculoskelet Disord ; 25(1): 204, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454432

RESUMO

BACKGROUND: The two major reverse shoulder arthroplasty (RSA) designs are the Grammont design and the lateralized design. Even if the lateralized design is biomechanically favored, the classic Grammont prosthesis continues to be used. Functional and subjective patient scores as well as implant survival described in the literature so far are comparable to the lateralized design. A pure comparison of how the RSA design influences outcome in patients has not yet been determined. The aim of this study was a comparison focused on patients with cuff tear arthropathy (CTA). METHODS: We analyzed registry data from 696 CTA patients prospectively collected between 2012 and 2020 in two specialized orthopedic centers up to 2 years post-RSA with the same follow-up time points (6,12 24 months). Complete teres minor tears were excluded. Three groups were defined: group 1 (inlay, 155° humeral inclination, 36 + 2 mm eccentric glenosphere (n = 50)), group 2 (inlay, 135° humeral inclination, 36 + 4 mm lateralized glenosphere (n = 141)) and group 3 (onlay, 145° humeral inclination, + 3 mm lateralized base plate, 36 + 2 mm eccentric glenosphere (n = 35)) We compared group differences in clinical outcomes (e.g., active and passive range of motion (ROM), abduction strength, Constant-Murley score (CS)), radiographic evaluations of prosthetic position, scapular anatomy and complications using mixed models adjusted for age and sex. RESULTS: The final analysis included 226 patients. The overall adjusted p-value of the CS for all time-points showed no significant difference (p = 0.466). Flexion of group 3 (mean, 155° (SD 13)) was higher than flexion of group 1 (mean, 142° (SD 18) and 2 (mean, 132° (SD 18) (p < 0.001). Values for abduction of group 3 (mean, 145° (SD 23)) were bigger than those of group 1 (mean, 130° (SD 22)) and group 2 (mean, 118° (SD 25)) (p < 0.001). Mean external rotation for group 3 (mean, 41° (SD 23)) and group 2 (mean, 38° (SD 17)) was larger than external rotation of group 1 (mean, 24° (SD 16)) (p < 0.001); a greater proportion of group 2 (78%) and 3 (69%) patients reached L3 level on internal rotation compared to group 1 (44%) (p = 0.003). Prosthesis position measurements were similar, but group 3 had significantly less scapular notching (14%) versus 24% (group 2) and 50% (group 1) (p = 0.001). CONCLUSIONS: Outcome scores of different RSA designs for CTA revealed comparable results. However, CTA patients with a lateralized and distalized RSA configuration were associated with achieving better flexion and abduction with less scapular notching. A better rotation was associated with either of the lateralized RSA designs in comparison with the classic Grammont prosthesis. LEVEL OF EVIDENCE: Therapeutic study, Level III.


Assuntos
Artroplastia do Ombro , Artropatia de Ruptura do Manguito Rotador , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Manguito Rotador/cirurgia , Desenho de Prótese , Amplitude de Movimento Articular , Resultado do Tratamento , Estudos Retrospectivos
4.
BMC Musculoskelet Disord ; 25(1): 439, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38835042

RESUMO

BACKGROUND: The use of reverse total shoulder arthroplasty (RTSA) has increased at a greater rate than other shoulder procedures. In general, clinical and functional outcomes after RTSA have been favorable regardless of indication. However, little evidence exists regarding patient specific factors associated with clinical improvement after RTSA. Predicting postoperative outcomes after RTSA may support patients and physicians to establish more accurate patient expectations and contribute in treatment decisions. The aim of this study was to determine predictive factors for postoperative outcomes after RTSA for patients with degenerative shoulder disorders. METHODS: EMBASE, PubMed, Cochrane Library and PEDro were searched to identify cohort studies reporting on predictive factors for postoperative outcomes after RTSA. Authors independently screened publications on eligibility. Risk of bias for each publication was assessed using the QUIPS tool. A qualitative description of the results was given. The GRADE framework was used to establish the quality of evidence. RESULTS: A total of 1986 references were found of which 11 relevant articles were included in the analysis. Risk of bias was assessed as low (N = 7, 63.6%) or moderate (N = 4, 36.4%). According to the evidence synthesis there was moderate-quality evidence indicating that greater height predicts better postoperative shoulder function, and greater preoperative range of motion (ROM) predicts increased postoperative ROM following. CONCLUSION: Preoperative predictive factors that may predict postoperative outcomes are: patient height and preoperative range of motion. These factors should be considered in the preoperative decision making for a RTSA, and can potentially be used to aid in preoperative decision making. LEVEL OF EVIDENCE: Level I; Systematic review.


Assuntos
Artroplastia do Ombro , Amplitude de Movimento Articular , Articulação do Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Resultado do Tratamento , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia
5.
BMC Musculoskelet Disord ; 25(1): 396, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773483

RESUMO

PURPOSE: This systematic review aims to provide an overview of the current knowledge on the role of the metaverse, augmented reality, and virtual reality in reverse shoulder arthroplasty. METHODS: A systematic review was performed using the PRISMA guidelines. A comprehensive review of the applications of the metaverse, augmented reality, and virtual reality in in-vivo intraoperative navigation, in the training of orthopedic residents, and in the latest innovations proposed in ex-vivo studies was conducted. RESULTS: A total of 22 articles were included in the review. Data on navigated shoulder arthroplasty was extracted from 14 articles: seven hundred ninety-three patients treated with intraoperative navigated rTSA or aTSA were included. Also, three randomized control trials (RCTs) reported outcomes on a total of fifty-three orthopedics surgical residents and doctors receiving VR-based training for rTSA, which were also included in the review. Three studies reporting the latest VR and AR-based rTSA applications and two proof of concept studies were also included in the review. CONCLUSIONS: The metaverse, augmented reality, and virtual reality present immense potential for the future of orthopedic surgery. As these technologies advance, it is crucial to conduct additional research, foster development, and seamlessly integrate them into surgical education to fully harness their capabilities and transform the field. This evolution promises enhanced accuracy, expanded training opportunities, and improved surgical planning capabilities.


Assuntos
Artroplastia do Ombro , Realidade Aumentada , Realidade Virtual , Humanos , Artroplastia do Ombro/métodos , Cirurgia Assistida por Computador/educação , Cirurgia Assistida por Computador/métodos , Articulação do Ombro/cirurgia
6.
BMC Musculoskelet Disord ; 25(1): 709, 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39232737

RESUMO

INTRODUCTION: In reverse shoulder arthroplasty (RSA) new designs enable greater amounts of lateralization to prevent instability and scapular notching and increase range of motion, however, excessive lateralization leads to stress upon the acromion that can result in scapular spine fatigue fractures. Aim of this study was to gender- and size-specifically assess the influence of glenosphere size and different humeral designs on lateralization, distalization, and bony impingement-free range of motion (ROM) in patients undergoing RSA. METHODS: Computed tomography scans from 30 osteoarthritic patients (f:15, m:15) and 20 cuff tear arthropathy patients (f:10, m:10) were used to virtually simulate RSA implantation. The efficacy of an inlay Grammont-type system vs. an onlay lateralizing system combined with different glenosphere sizes (36 mm vs. 42 mm) in achieving ROM, lateralization, and distalization was evaluated. Moreover, gender and patient's constitution were correlated to humeral size by radiologically measuring the best-fit circle of the humeral head. RESULTS: A different amount of relative lateralization was achieved in both genders using large glenospheres and onlay designs. Latter yielded a higher ROM in all planes for men and women with a 42 mm glenosphere; with the 36 mm glenosphere, an increased ROM was observed only in men. The 155° inlay design led to joint medialization only in men, whereas all designs led to lateralization in women. When adjusting the absolute amount of lateralization to humerus' size (or patient's height), regardless of implant type, women received greater relative lateralization using 36 mm glenosphere (inlay: 1%; onlay 12%) than men with 42 mm glenosphere (inlay: -3%; onlay: 8%). CONCLUSION: The relative lateralization achieved using onlay design is much higher in women than men. Small glenospheres yield greater relative lateralization in women compared to large glenospheres in men. Humeral lateralization using onlay designs should be used cautiously in women, as they lead to great relative lateralization increasing stress onto the acromion. LEVEL OF EVIDENCE: Basic Science Study, Computer Modeling.


Assuntos
Artroplastia do Ombro , Desenho de Prótese , Amplitude de Movimento Articular , Articulação do Ombro , Prótese de Ombro , Humanos , Feminino , Masculino , Artroplastia do Ombro/métodos , Artroplastia do Ombro/instrumentação , Idoso , Pessoa de Meia-Idade , Articulação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Fatores Sexuais , Osteoartrite/cirurgia , Osteoartrite/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso de 80 Anos ou mais , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico por imagem
7.
BMC Musculoskelet Disord ; 25(1): 13, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167047

RESUMO

BACKGROUND: Reverse shoulder arthroplasty (RSA) is a valuable treatment for rotator cuff arthropathy (RCA) in developed regions. Socioeconomic issues impact access to specialized care and there is a lack of data on RSA outcomes in developing regions. We present our 24-month follow-up on RSA surgeries to treat RCA in our low-income population. METHODS: Prospective evaluation of 26 patients subjected to RSA at Hospital Geral de Fortaleza-CE, Brazil, between January 2018 and December 2020. Literacy [>/≤ 8 school years(SY)] and income were documented. Outcomes considered pain (visual analogue scale; VAS) as well as SSV, SPADI, ASES, and UCLA scoring, and range of motion [forward flexion (FF); external rotation (ER)]. RESULTS: Patients were 68.5 ± 7.6 years-old with 16(61.5%) females; 65% had hypertension and 7 (26.9%) had diabetes. Over 90% declared < 900.00 US$ monthly family earnings and 10 (38.4%) patients declared ≤8 SY with > 80% exerting blue-collar jobs. Pain showed a significant reduction from baseline (8 ± 2) to 24 months (2.1 ± 2.3; p < 0.001). UCLA (10.3 ± 5.6 and 28.6 ± 7.2), ASES (16.7 ± 10.8 and 63.1 ± 28.4), SSV (326 ± 311 and 760 ± 234), and SPADI (98.3 ± 26.5) scores significantly improved from baseline to 24 months, achieving minimal clinically important difference. FF (89.2° ± 51.2° to 140.6 ± 38.3°) and ER (19.2° ± 22.5 to 33.4° ± 20.6°) significantly improved from baseline to 24 months (p = 0.004 and 0.027, respectively). There were 5 non-serious adverse events with one surgical revision. All patients returned to daily life activities. CONCLUSION: This is the first outcome report 2 years following RSA in a low-income population. Data indicate this procedure is justifiable regardless of socioeconomic issues.


Assuntos
Artroplastia do Ombro , Artropatias , Lesões do Manguito Rotador , Articulação do Ombro , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Manguito Rotador/cirurgia , Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/métodos , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Resultado do Tratamento , Artropatias/cirurgia , Amplitude de Movimento Articular , Dor , Pobreza , Articulação do Ombro/cirurgia , Estudos Retrospectivos
8.
BMC Musculoskelet Disord ; 25(1): 231, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38521910

RESUMO

BACKGROUND: The current study aimed to determine the changes in pre-and post-operative Pittsburg sleep quality index (PSQI) and Tampa scale of kinesiophobia (TSK) values ​​according to the Hamada classification in patients who underwent reverse shoulder arthroplasty (RSA) for rotator cuff tear arthropathy (RCTA). METHODS: One hundred and eight patients who underwent RSA for RCTA were reviewed retrospectively. The patients were divided into two groups with low grade (stages 1-2-3) (n = 49) and high grade (stages 4a-4b-5) (n = 59) according to the Hamada classification, which is the radiographic evaluation of RCTA. PSQI and TSK values ​​were calculated preoperatively, and post-operatively at the 6th week, 6th month, and 1st year. The change in PSQI and TSK values ​​between the evaluations and the effect of staging according to the Hamada classification on this change was examined. RESULTS: When compared in preoperative evaluations, PSQI and TSK scores were found to be lower in low-grade group 1 (7.39 ± 1.56, 51.88 ± 4.62, respectively) than in high-grade group 2 (10.47 ± 2.39, 57.05 ± 3.25, respectively) according to Hamada classification (both p < 0.001). In the postoperative evaluations, PSQI and TSK results decreased gradually compared to the preoperative evaluations, and there was a severe decrease in both parameters between the 6th-week and 6th-month evaluations (both p < 0.001). Preoperatively, 102 (95%) patients had sleep disturbance (PSQI ≥ 6), and 108 (100%) patients had high kinesiophobia (TSK > 37). In the 1st year follow-ups, sleep disturbance was observed in 5 (5%) patients and kinesiophobia in 1 (1%) patient. When the Hamada stages were compared, it was seen that there was a significant difference before the operation (both p < 0.001), but the statistically significant difference disappeared in the PSQI value in the 1st year (p = 0.092) and in the TSK value in the 6th month (p = 0.164) post-operatively. It was observed that Hamada staging caused significant differences in PSQI and TSK values ​​in the preoperative period but did not affect the clinical results after treatment. CONCLUSIONS: RSA performed based on RCTA improves sleep quality and reduces kinesiophobia. RCTA stage negatively affects PSQI and TSK before the operation but does not show any effect after the treatment.


Assuntos
Artroplastia do Ombro , Artropatias , Lesões do Manguito Rotador , Artropatia de Ruptura do Manguito Rotador , Articulação do Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/métodos , Manguito Rotador/cirurgia , Estudos Retrospectivos , Cinesiofobia , Resultado do Tratamento , Artropatia de Ruptura do Manguito Rotador/cirurgia , Artropatias/cirurgia , Sono , Lesões do Manguito Rotador/complicações , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia , Amplitude de Movimento Articular
9.
BMC Musculoskelet Disord ; 25(1): 17, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166758

RESUMO

BACKGROUND: Various surgical techniques and conservative therapies are useful tools for treating proximal humerus fractures (PHFs), but it is important to understand how to properly utilize them. Therefore, we performed a systematic review and network meta-analysis to compare and rank the efficacy and safety of medical treatments for PHF. METHODS: PubMed, Embase, the Cochrane Library, and the ClinicalTrials.gov databases were systematically searched for eligible randomized controlled trials (RCTs) from inception until June 2022. Conservative therapy-controlled or head-to-head RCTs of open reduction internal fixation (ORIF), intramedullary nailing (IMN), hemiarthroplasty (HA), and reverse total shoulder arthroplasty (RTSA) used for the treatment of adult patients with PHF were included. The surface under the cumulative ranking (SUCRA) probabilities were applied to compare and rank the effects of medical treatments for PHF. RESULTS: Eighteen RCTs involving 1,182 patients with PHF were selected for the final analysis. Mostly baseline characteristics among groups were well balanced, and the imbalanced factors only included age, injury type, medial comminution, blood loss, and cognitive function in single trial. The SUCRA probabilities found that RTSA provided the best effect on the Constant-Murley score (SUCRA: 100.0%), and the disabilities of the arm, shoulder and hand (DASH) score (SUCRA: 99.0%). Moreover, HA (SUCRA: 85.5%) and RTSA (SUCRA: 68.0%) had a relatively better effect on health-related quality of life than the other treatment modalities. Furthermore, conservative therapy (SUCRA: 84.3%) and RTSA (SUCRA: 80.7%) were associated with a lower risk of secondary surgery. Finally, the best effects on the risk of complications are varied, including infection was observed with conservative therapy (SUCRA: 94.2%); avascular necrosis was observed in HA (SUCRA: 78.1%), nonunion was observed in RTSA (SUCRA: 69.6%), and osteoarthritis was observed in HA (SUCRA: 93.9%). CONCLUSIONS: This study found that RTSA was associated with better functional outcomes, while the comparative outcomes of secondary surgery and complications varied. Optimal treatment for PHF should consider patient-specific factors.


Assuntos
Artroplastia do Ombro , Hemiartroplastia , Fraturas do Úmero , Fraturas do Ombro , Adulto , Humanos , Hemiartroplastia/efeitos adversos , Fraturas do Úmero/cirurgia , Úmero/cirurgia , Metanálise em Rede , Fraturas do Ombro/cirurgia , Fraturas do Ombro/etiologia , Resultado do Tratamento
10.
BMC Musculoskelet Disord ; 25(1): 752, 2024 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-39304857

RESUMO

BACKGROUND: Insufficient tuberosity healing is the most common reason for poor outcome after treatment of proximal humerus fractures (PHFs) using hemiarthroplasty (HA). In these cases, revision to reverse total shoulder arthroplasty (RTSA) can improve function and reduce pain in the short term, however, long-term results remain scarce. Aim of this study was to evaluate the clinical and radiological mid- to long-term results in patients with a revision RTSA after failed HA for PHF. METHODS: In this retrospective study all patients that received a revision to RTSA after failed fracture HA between 2006 and 2018 were included. A total of 49 shoulders in 48 patients (38 female, 10 male; mean age 82 ± 9 years) were identified in our database. A total of 20 patients (17 female, 3 male; mean age was 79 ± 9 years) were available for follow-up examination after a mean time period of approximately eight years (3-14 years) after revision surgery. At final follow-up, patients were assessed using a subjective shoulder value (SSV), range of motion (ROM), visual analogue score (VAS), the Constant Score (CS) and the 12-Item Short Form Survey (SF-12). RESULTS: At final follow-up, mean CS was 55 ± 19 (19-91), VAS averaged 3 ± 3 (0-8) and mean SSV was 61 ± 18% (18-90%). Mean SF-12 was 44 (28-57) with a mean physical component summary (PCS) of 38 (21-56) and a mean mental component summary (MCS) of 51 (29-67). On average active forward flexion (FF) was 104° (10-170°), active abduction (ABD) was 101° (50-170°), active external rotation (ER) was 19° (10-30°) and active internal rotation (IR) of the lumbosacral transition was reached. Three patients presented with a periprosthetic humeral fracture after RTSA implantation and underwent a reoperation (15%) during follow-up period. CONCLUSIONS: Revision RTSA results in promising clinical results in patients after initial failed HA after PHF. A complication and reoperation rate of 15% is tolerable in consideration of satisfactory functional and psychological outcome. TRIAL REGISTRATION: Retrospectively registered.


Assuntos
Artroplastia do Ombro , Hemiartroplastia , Amplitude de Movimento Articular , Reoperação , Fraturas do Ombro , Humanos , Feminino , Masculino , Idoso , Fraturas do Ombro/cirurgia , Fraturas do Ombro/diagnóstico por imagem , Estudos Retrospectivos , Artroplastia do Ombro/métodos , Idoso de 80 Anos ou mais , Hemiartroplastia/métodos , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Articulação do Ombro/diagnóstico por imagem , Seguimentos , Falha de Tratamento , Resultado do Tratamento
11.
Artigo em Inglês | MEDLINE | ID: mdl-39244149

RESUMO

OBJECTIVE: This retrospective, observational study aimed to assess the revision rates and survival curves in total shoulder arthroplasty (TSA) and hemi-shoulder arthroplasty (HSA) patients, including a sub analysis to investigate the impact of pyrocarbon humeral head in revision rates. METHODS: Data from 92 primary HSA and 508 primary TSA patients performed by seven surgeons at a large private clinic, were analyzed. The study focused on revision rates and identified factors leading to revisions, including rotator cuff insufficiency, dislocation, aseptic loosening, implant material, and glenoid erosion. RESULTS: The overall revision rate for HSA was found to be significantly higher at 7.6% compared to TSA at 1.2% with a maximum follow-up of seven years. Sub-analysis within the HSA group revealed a notably higher revision rate in cases involving a metal head (cobalt-chrome or titanium) at 12.8% compared to those with a pyrocarbon head (2.3%). CONCLUSION: This study underscores the importance of distinguishing between TSA and HSA when evaluating shoulder arthroplasty outcomes. The significantly higher revision rate in HSA, particularly with metal heads, suggests the need for careful consideration of implant selection to optimize long-term success in shoulder arthroplasty procedures.

12.
J Shoulder Elbow Surg ; 33(2): 281-290, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37499786

RESUMO

BACKGROUND: We compared the rate of all-cause revision of 2 classes of primary anatomic shoulder arthroplasty, stemmed (stTSA) and stemless (slTSA), undertaken with cemented all-polyethylene glenoid components. METHODS: A large national arthroplasty registry identified 2 cohort groups for comparison, stTSA and l undertaken for all diagnoses between January 1, 2011, and December 31, 2021. A subanalysis from January 1, 2017, allowed capturing of additional patient demographics including American Society of Anesthesiologists score, body mass index, and glenoid morphology. The cumulative percent revision (CPR) was determined using Kaplan-Meier estimates of survivorship and hazard ratios (HR) from Cox proportional hazard models adjusted for age and gender. RESULTS: Of the 7995 stTSA procedures, the CPR at 9 years was 5.6% (95% confidence interval [CI]: 5.0, 6.4), and for 3156 slTSA procedures, the CPR was 4.4% (95% CI: 3.6, 5.5). There was no significant difference in the rate of revision between the study groups (HR = 0.76 [95% CI: 0.51, 1.14], P = .189, adjusted for age, gender, humeral head size, humeral fixation, bearing surface, glenoid design, and mean surgeon volume [MSV]). There was an increased rate of revision for stTSA and slTSA undertaken with humeral head sizes <44 mm (stTSA <44 mm vs. 44-50 mm, HR = 1.56 [CI: 1.18, 2.08], P = .001; slTSA <44 mm vs. 44-50 mm, HR = 2.08 [CI: 1.32, 3.33], P = .001). MSV as a continuous predictor was not a revision risk to stTSA vs. slTSA, but categorically, a low MSV (<10 stTSA + slTSA cases per annum) was associated with a higher revision rate for stTSA (10-20 cases/yr vs. <10 cases/yr, HR = 0.72 [CI: 0.55, 0.95], P = .019) but was not in slTSA. Revision rates were increased for stTSA with non-crosslinked polyethylene (XLPE) glenoids vs. XPLE after 2 years (HR = 2.20 [CI: 1.57, 3.08], P < .001) but did not significantly differ for slTSA. Metal/XPLE (humeral/glenoid) bearing surface of stTSA rate of revision was not different from each combination of slTSA bearing surface. Instability/dislocation was a revision risk for slTSA vs. stTSA (HR = 1.93 [CI: 1.28, 2.91], P = .001), but from 2017, neither of American Society of Anesthesiologists score, body mass index, and glenoid morphology changed the rate of revision. CONCLUSIONS: Revision rates of stTSA and slTSA did not significantly differ and were associated with humeral head size but not patient characteristics. Surgeon inexperience of anatomic shoulder arthroplasty and non-XLPE glenoids were risk factors for stTSA revision but not slTSA. The metal/XLPE stTSA rate of revision was not found to differ significantly from slTSA regardless of polyethylene or humeral head bearing type. Revision for instability/dislocation was more common for slTSA.


Assuntos
Artroplastia do Ombro , Luxações Articulares , Ortopedia , Articulação do Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Polietileno , Desenho de Prótese , Austrália , Luxações Articulares/cirurgia , Sistema de Registros , Resultado do Tratamento , Articulação do Ombro/cirurgia , Reoperação
13.
J Shoulder Elbow Surg ; 33(8): e438-e442, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38642875

RESUMO

BACKGROUND: Prior research has shown that industry funding can impact the outcomes reported in medical literature. Limited data exist on the degree of bias that industry funding may have on shoulder arthroplasty literature outside of the Journal of Shoulder and Elbow Surgery. The purpose of this study is to characterize the type and frequency of funding for recently published shoulder arthroplasty studies and the impact of industry funding on reported outcomes. We hypothesized that studies with industry funding are more likely to report positive outcomes than those without. MATERIALS AND METHODS: We performed a retrospective study searching all articles with the term "shoulder arthroplasty," "reverse shoulder arthroplasty," "anatomic total shoulder arthroplasty," or "total shoulder arthroplasty" on PubMed from the years January 2020 to December 2022. The primary outcome of studies was coded as either positive, negative, or neutral. A positive result was defined as one in which the null hypothesis was rejected. A negative result was defined as one in which the result did not favor the group in which the industry-funded implant was used. A neutral result was defined as one in which the null hypothesis was confirmed. Article funding type, subcategorized as National Institutes of Health funding or industry funding was recorded. Author disclosures were recorded to determine conflicts of interest. Statistical analysis was conducted using the χ2 test and Fisher exact test. RESULTS: A total of 750 articles reported on either conflict of interest or funding source and were included in the study. Of the total number of industry-funded studies, the majority were found to have a positive primary endpoint (58.1%, 104 of 179), as compared to a negative (7.8%, 14 of 179) or neutral endpoint (33.5%, 60 of 179) (P = .004). Overall, 363 articles reported an author conflict of interest, and the majority of these studies had positive primary endpoint (55.6%, 202 of 363) as compared to negative (9.1%, 33 of 363) or neutral endpoints (34.4%, 125 of 363) (P = .002). CONCLUSION: The results of this study suggest that there is a significant relationship between conflicts of interest and the primary outcome of shoulder arthroplasty studies, beyond the overall positive publication bias. Studies with industry funding and author conflicts of interest both report positive outcomes more frequently than negative outcomes. Shoulder surgeons should be aware of this potential bias when choosing to base clinical practice on published data.


Assuntos
Artroplastia do Ombro , Humanos , Artroplastia do Ombro/economia , Estudos Retrospectivos , Pesquisa Biomédica/economia , Conflito de Interesses , Apoio à Pesquisa como Assunto
14.
J Shoulder Elbow Surg ; 33(5): e233-e247, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37852429

RESUMO

BACKGROUND: Inflammatory arthritis (IA) represents a less common indication for anatomic and reverse total shoulder arthroplasty (TSA) than osteoarthritis (OA). The safety and efficacy of anatomic and reverse TSA in this population has not been as well studied compared to OA. We analyzed the differences in outcomes between IA and OA patients undergoing TSA. METHODS: Patients who underwent primary anatomic total shoulder arthroplasty (aTSA) and reverse total shoulder arthroplasty (rTSA) from 2016-2020 were identified in the Premier Healthcare Database. Inflammatory arthritis (IA) patients were identified using International Classification of Diseases, Tenth Revision, diagnosis codes and compared to osteoarthritis controls. Patients were matched in a 1:8 fashion by age (±3 years), sex, race, and presence of pertinent comorbidities. Patient demographics, hospital factors, and patient comorbidities were compared. Multivariate regression was performed following matching to account for any residual confounding and 90-day complications were compared between the 2 cohorts. Descriptive statistics and regression analysis were employed with significance set at P < .05. RESULTS: Prior to matching, 5685 IA cases and 93,539 OA controls were identified. Patients with IA were more likely to be female, have prolonged length of stay and increased total costs (P < .0001). After matching and multivariate analysis, 4082 IA cases and 32,656 controls remained. IA patients were at increased risk of deep wound infection (OR 3.14, 95% CI 1.38-7.16, P = .006), implant loosening (OR 4.11, 95% CI 1.17-14.40, P = .027), and mechanical complications (OR 6.34, 95% CI 1.05-38.20, P = .044), as well as a decreased risk of postoperative stiffness (OR 0.36, 95% CI 0.16-0.83, P = .002). Medically, IA patients were at increased risk of PE (OR 2.97, 95% CI 1.52-5.77, P = .001) and acute blood loss anemia (OR 1.27, 95% CI 1.12-1.44, P < .0001). DISCUSSION AND CONCLUSION: Inflammatory arthritis represents a distinctly morbid risk profile compared to osteoarthritis patients with multiple increased surgical and postoperative medical complications in patients undergoing aTSA and rTSA. Surgeons should consider these potential complications and employ a multidisciplinary approach in preoperative risk stratification of IA undergoing shoulder replacement.


Assuntos
Artroplastia do Ombro , Artroplastia de Substituição , Osteoartrite , Articulação do Ombro , Humanos , Feminino , Masculino , Artroplastia do Ombro/efeitos adversos , Artroplastia de Substituição/efeitos adversos , Complicações Pós-Operatórias/etiologia , Osteoartrite/complicações , Estudos de Coortes , Estudos Retrospectivos , Resultado do Tratamento , Articulação do Ombro/cirurgia
15.
J Shoulder Elbow Surg ; 33(4): 900-907, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37625693

RESUMO

BACKGROUND: Outpatient total shoulder arthroplasty (TSA) presents a safe alternative to inpatient arthroplasty, while helping meet the rapidly rising volume of shoulder arthroplasty needs and minimizing health care costs. Identifying the correct patient for outpatient surgery is critical to maintaining the safety standards with TSA. This study sought to update an ambulatory surgery center (ASC) TSA patient-selection algorithm previously published by our institution. METHODS: A retrospective chart review of TSAs was performed in an ASC at a single institution to collect patient demographics, perioperative risk factors, and postoperative outcomes with regard to reoperations, hospital admissions, and complications. The existing ASC algorithm for outpatient TSA was altered based on collected perioperative information, review of pertinent literature, and anesthesiology recommendations. RESULTS: A total of 319 TSAs were performed in an ASC in 298 patients over 7 years. Medically related complications occurred in 3 patients (0.9%) within 90 days of surgery, 2 of whom required hospital admission (0.6%) for acute kidney injury and pulmonary embolus. There were no instances of major cardiac events. Orthopedic-related complications occurred in 11 patients (3.4%), with hematoma development requiring evacuation and instability requiring revision being the most common causes. CONCLUSIONS: There was a low rate of perioperative complications and hospital admissions, confirming the safety of TSAs in an ASC setting. Based on prior literature and the population included, a pre-existing patient-selection algorithm was updated to better reflect increased comfort, knowledge, and data regarding safe patient selection for TSA in an ASC.


Assuntos
Artroplastia do Ombro , Humanos , Estudos Retrospectivos , Procedimentos Cirúrgicos Ambulatórios/efeitos adversos , Pacientes Ambulatoriais , Seleção de Pacientes , Algoritmos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
16.
Artigo em Inglês | MEDLINE | ID: mdl-39270774

RESUMO

BACKGROUND: Revision shoulder arthroplasty continues to add an increasing burden on patients and the healthcare system. This study aimed to delineate long-term shoulder arthroplasty revision incidence, quantify associated Medicare spending, and identify relevant predictors of both revision and spending. METHODS: The complete 2016-2022(Q3) Medicare fee-for-service inpatient and outpatient claims data was analyzed. Patients receiving a primary total shoulder arthroplasty for osteoarthritis, rotator cuff pathology, or inflammatory arthropathy were included and subsequent ipsilateral revision surgeries were identified. The time to revision was modeled using the Prentice, Williams, and Peterson Gap Time Model. Medicare spending within 90 days post-discharge was modeled using a generalized linear model. The analysis was subdivided by index procedure type: anatomic total shoulder arthroplasty (TSA) and reverse shoulder arthroplasty (RSA). RESULTS: A total of 82,949 primary TSAs and 172,524 RSAs were identified. Compared to index TSA cases, index RSA cases had a lower first revision rate in an observation window of nearly 7 years (1.9% vs. 3.5%, p<0.001), but a higher rate of second (11.4% vs. 4.9%, p<0.001) as well as third revision (13.8% vs. 13.8%, p=0.449). TSA spending was significantly lower than RSA spending for the index procedure ($21,531 vs. $23,267, p<0.001), first ($23,096 vs. $26,414, p<0.001), and second ($25,060 vs. $29,983, p<0.001) revision. There was no statistically significant difference in third revision between TSA and RSA groups ($31,313 vs. $30,829, p=0.860). Age, sex, race, and rheumatoid arthritis were among the top predictors of revisions. Top predictors of Medicare spending included having a non-osteoarthritis surgical indication, a hospital stay of three or more days, a discharge to a setting other than home, malnutrition, dementia, stroke, major kidney diseases, and being operated on in a teaching hospital. CONCLUSION: Compared with TSA, RSA was associated with a lower first revision rate, but a higher subsequent revision rate. An index RSA procedure was also associated with higher initial Medicare spending as well as subsequent revision surgery spending compared with an index TSA procedure. Demographics and comorbid medical conditions were among the top predictors of revisions, while procedure-related factors predicted Medicare spending.

17.
Artigo em Inglês | MEDLINE | ID: mdl-38810910

RESUMO

BACKGROUND: Patients who rely on their upper extremities for ambulation, or upper extremity ambulators (UEAs), place considerable stress on their shoulders through the use of assistive devices like walkers, crutches, canes, and wheelchairs. It has been postulated that UEAs may be at increased risk for complications following shoulder arthroplasty. This study aimed to systematically review the literature related to (1) patient-reported outcomes measures (PROMs), (2) functional outcomes, and (3) complications in UEAs who undergo shoulder arthroplasty. METHODS: A systematic review of the PubMed/MEDLINE, Embase, and Cochrane databases was performed to identify studies reporting clinical outcomes of shoulder arthroplasty in UEAs. Patient demographics, clinical characteristics, patient-reported outcomes measures, radiographic outcomes, and postoperative range of motion were collected and compared to control patients (ie bipedal ambulators) from the constituent studies. RESULTS: A total of eight studies evaluating 248 UEA cases and 206 control cases were included for review. Ambulatory assistive devices utilized by UEAs included walkers (39%), wheelchairs (38%), canes (22%), and a crutch (<1%). Among UEA cases, 197 (79%) reverse total shoulder arthroplasty (TSA), 37 (15%) anatomic TSA, and 14 (6%) hemiarthroplasty were performed. Overall, patients exhibited significant improvements in mean American Shoulder and Elbow Surgeons scores, Constant-Murley scores, Simple Shoulder Test scores, and Visual Analog Scale scores postoperatively. Among 3 studies that included comparison with control groups of bipedal ambulators, no significant differences in outcomes were identified. The overall clinical complication rate was 17% for UEAs compared to 9.1% for controls. The rate of revision surgery was 7.7% for UEAs and 4.9% for bipedal ambulators. CONCLUSIONS: UEAs experience satisfactory pain relief, functional improvements, and good subjective outcomes following shoulder arthroplasty. However, complication and revision rates are higher compared to those for bipedal ambulators, and the majority of UEAs undergo reverse shoulder arthroplasty compared to anatomic TSA.

18.
J Shoulder Elbow Surg ; 33(3): 707-714, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37543279

RESUMO

BACKGROUND: Baseplate failure in reverse shoulder arthroplasty (RSA) is a rare but potentially catastrophic complication owing to poor patient outcomes and significant glenoid bone loss. The purpose of this study was to report on the prevalence, causes, and outcomes of revision RSA (rRSA) for baseplate failure or loosening. METHODS: A retrospective review of our institutional database was performed to identify all patients treated for a failed RSA from 2006 to 2021 who required revision to another RSA (rRSA) performed by a single surgeon. A total of 676 failed RSA procedures were identified, and further analysis identified 46 patients (6.8%) who underwent rRSA for baseplate failure with a confirmed loose baseplate at the time of rRSA. The primary outcome was repeated failure of the reimplanted baseplate following rRSA. The mode of failure associated with baseplate failure was stratified into 1 of 3 groups: aseptic, septic, or traumatic. Twenty-four patients underwent primary revision, and 22 had undergone >1 previous arthroplasty prior to undergoing re-revision. Five patients underwent previous rRSA for baseplate failure performed by an outside surgeon. The criteria for secondary outcome analysis of final American Shoulder and Elbow Surgeons score, Simple Shoulder Test score, and range of motion were met by 32 patients and 23 patients at 1- and 2-year follow-up, respectively. RESULTS: Three patients (6.5%) had repeated baseplate failure requiring re-revision; 2 had baseplate failure at <1 year with associated periprosthetic infections and underwent conversion to hemiarthroplasty. The third patient experienced traumatic failure at 10 years and underwent successful rRSA. The mean American Shoulder and Elbow Surgeons scores at 1 and 2 years were 62.3 and 61.7, respectively. There was no significant difference in outcomes based on mode of baseplate failure (P = .232) or total arthroplasty burden (P = .305) at 1 year. There were 13 total complications in 11 patients, 5 of which required reoperation for reasons other than baseplate failure. CONCLUSION: In this study, rRSA for baseplate failure constituted 6.8% of all revisions performed over a period of 15 years. Re-revision for recurrent baseplate failure was required in 3 of 46 patients (6.5%). Complications and reoperation rates were higher than those for primary RSA but outcomes were comparable for revision of failed anatomic shoulder arthroplasty.


Assuntos
Artroplastia do Ombro , Hemiartroplastia , Articulação do Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/cirurgia , Falha de Prótese , Estudos Retrospectivos , Hemiartroplastia/efeitos adversos , Reoperação/métodos , Resultado do Tratamento , Amplitude de Movimento Articular
19.
J Shoulder Elbow Surg ; 33(2): 425-434, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37696486

RESUMO

BACKGROUND: Elderly patients and their surgeons may eschew shoulder arthroplasty due to concerns over patient safety and longevity. The purpose of this study was to review the current literature evaluating the clinical and radiographic outcomes of shoulder arthroplasty performed in patients 80 years and older. METHODS: A literature search of the Embase, PubMed, Medline, and Cochrane databases was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Studies evaluating the outcomes of primary and revision anatomic (aTSA) and reverse (RSA) total shoulder arthroplasty in patients 80 years and older were included for analysis. RESULTS: A total of 15 studies evaluating 1685 primary aTSAs, 1170 primary RSAs, 69 RSAs performed for fracture, and 45 revision RSAs were included for review. The postoperative active forward flexion and external rotation ranged from 138° to 150° and 45° to 48° after aTSA and from 83° to 139° and 16° to 47° after RSA, respectively. Postoperative visual analog scale pain scores ranged from 0 to 1.8 after aTSA and from 0 to 1.4 after RSA. Ninety-day mortality ranged from 0% to 3%, and perioperative complications ranged from 0% to 32%. Late complications ranged from 5.6% to 24% for aTSA patients and 3.5% to 29% for patients undergoing RSA for all indications. Common complications included glenoid loosening (0%-18%) and rotator cuff tear (5.6%-10%) after aTSA and scapular notching (0%-40%) and scapular fracture (4%-9.4%) after RSA. Reoperation rates ranged from 0% to 6% after aTSA and from 0% to 13% after RSA. CONCLUSIONS: aTSA and RSA in this population are safe and effective, demonstrating low rates of perioperative mortality and reoperation, durability that exceeds patient longevity, satisfactory postoperative range of motion, and excellent pain relief. Late complication rates appear to be similar for aTSA and RSA.


Assuntos
Artroplastia do Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Dor/etiologia , Amplitude de Movimento Articular , Fraturas do Ombro/cirurgia , Articulação do Ombro/cirurgia , Resultado do Tratamento , Idoso de 80 Anos ou mais
20.
Artigo em Inglês | MEDLINE | ID: mdl-38944375

RESUMO

BACKGROUND: Current options for reconstruction of large glenoid defects in reverse total shoulder arthroplasty (RTSA) include structural bone grafting, use of augmented components, or 3D-printed custom implants. Given the paucity in the literature on structural bone grafts in RTSA, this study reflects our experience on clinical and radiographic outcomes of structural bone grafts used for glenoid defects in RTSA. METHODS: We identified 33 consecutive patients who underwent RTSA using structural bone grafts for glenoid bone loss between 2008 and 2019. Twenty-six patients with a mean clinical follow-up of 4.4 ± 3.9 years and a mean radiographic follow-up of 2.7 ± 3.2 years were included. Patient demographic data, perioperative functional outcomes, radiographic outcomes, complications, and reoperation rates were determined. RESULTS: Between 2008 and 2019, 26 RTSAs were performed using structural autograft or allograft for glenoid defects. There were 20 females (77%) and 6 males (23%), with a mean presenting age of 68 years (range 41-86), mean BMI of 29 (range 21-44), and mean Charlson Comorbidity Index of 3 (range 0-8). There were 19 cases of central glenoid defects, and 7 were combined central and peripheral defects. Structural grafts included humeral head autograft (7), proximal humerus autograft (7), iliac crest autograft (7), distal clavicle autograft (2), and femoral head allograft (3). All 18 revision RTSA cases had simultaneous humeral-sided revision. There was significant postoperative improvement in American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form scores (27.0 ± 12.6 preoperation vs. 59.8 ± 24.1 postoperation; P < .001) and visual analog scale scores (8.1 ± 3.6 preoperation vs. 3.0 ± 3.2 postoperation; P < .001). Range of motion improved significantly for active forward elevation (63° ± 36° preoperation vs. 104° ± 36° postoperation; P < .001) and external rotation (21° ± 20° preoperation vs. 32° ± 23° postoperation, P = .036). Eighty-eight percent of cases (23 of 26) had successful reconstruction of the glenoid, defined as no visible radiolucent lines nor glenoid component migration at final follow-up. The reoperation rate was 19% (5 of 26). Postoperative complications included 2 cases of acromial stress fractures that were treated nonoperatively, for a total complication rate (including reoperation) of 27% (7 of 26 cases). CONCLUSIONS: The use of structural bone autografts and allografts in RTSA was associated with improved outcome scores and range of motion. A reoperation rate of 19% and total complication rate of 27% were reported for these challenging cases. However, 86% of these complications were not related to structural glenoid reconstruction failure. Structural grafts are a reasonable option for glenoid reconstruction in RTSA cases with glenoid bone loss.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA