Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 465
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 39(8S1): S218-S223, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38417556

RESUMO

BACKGROUND: Optimal soft-tissue management in total knee arthroplasty (TKA) may reduce symptomatic instability. We hypothesized that TKA outcomes using a computer-assisted dynamic ligament balancer that acquires medial and lateral gap sizes throughout the motion arc would show improved Knee Society Scores (KSS) compared to TKAs done with a traditional tensioner at 0 and 90°. We also sought to quantify the degree to which the planned femoral rotation chosen to optimize medio-lateral balance throughout the arc of motion deviated from the femoral rotation needed to achieve a rectangular flexion gap at 90° alone. METHODS: Baseline demographics, clinical outcomes, KSSs, and femoral rotations were compared in 100 consecutive, computer-assisted TKAs done with the balancer (balancer group) to the immediately prior 100 consecutive computer-assisted TKAs done without the balancer (control group). Minimum follow-up was 13 months and all patients had osteoarthritis. Mean knee motion did not differ preoperatively (110.1 ± 13.6° balancer, 110.4 ± 12.5° control, P = .44) or postoperatively (119.1 ± 10.3° balancer, 118.8 ± 10.9° control, P = .42). Tourniquet times did not differ (93.1 ± 13.0 minutes balancer, 90.7 ± 13.0 minutes control, P = .13). Postoperative length of stay differed (40.2 ± 20.9 hours balancer, 49.0 ± 18.3 hours control, P = .0009). There were 14 readmissions (7 balancer, 7 control), 11 adverse events (4 balancer, 7 control), and 3 manipulations (1 balancer, 2 control). The cohorts were compared using Student's t-tests, Shapiro-Wilk normalities, Wilcoxon rank-sums, and multivariable logistic regression analyses. RESULTS: Postoperative KSS improvements were higher in the balancer group (P < .0001). In multivariable regression analyses, the balancer group experienced 7 ± 2 point improvement in KSS Knee scores (P < .0001) and 4 ± 2 point improvement in KSS Function scores (P = .040) compared to the control group. CONCLUSIONS: The statistically and clinically significant improvements in postoperative KSS demonstrated in the balancer cohort are likely driven by improved stability throughout the motion arc. Further study is warranted to evaluate replicability by non-design surgeons.


Assuntos
Artroplastia do Joelho , Articulação do Joelho , Osteoartrite do Joelho , Amplitude de Movimento Articular , Humanos , Artroplastia do Joelho/métodos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiopatologia , Osteoartrite do Joelho/cirurgia , Cirurgia Assistida por Computador/métodos , Estudos Retrospectivos , Instabilidade Articular/cirurgia , Instabilidade Articular/prevenção & controle , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos
2.
Sensors (Basel) ; 24(14)2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39066150

RESUMO

Periacetabular osteotomy (PAO) is an effective approach for the surgical treatment of developmental dysplasia of the hip (DDH). However, due to the complex anatomical structure around the hip joint and the limited field of view (FoV) during the surgery, it is challenging for surgeons to perform a PAO surgery. To solve this challenge, we propose a robot-assisted, augmented reality (AR)-guided surgical navigation system for PAO. The system mainly consists of a robot arm, an optical tracker, and a Microsoft HoloLens 2 headset, which is a state-of-the-art (SOTA) optical see-through (OST) head-mounted display (HMD). For AR guidance, we propose an optical marker-based AR registration method to estimate a transformation from the optical tracker coordinate system (COS) to the virtual space COS such that the virtual models can be superimposed on the corresponding physical counterparts. Furthermore, to guide the osteotomy, the developed system automatically aligns a bone saw with osteotomy planes planned in preoperative images. Then, it provides surgeons with not only virtual constraints to restrict movement of the bone saw but also AR guidance for visual feedback without sight diversion, leading to higher surgical accuracy and improved surgical safety. Comprehensive experiments were conducted to evaluate both the AR registration accuracy and osteotomy accuracy of the developed navigation system. The proposed AR registration method achieved an average mean absolute distance error (mADE) of 1.96 ± 0.43 mm. The robotic system achieved an average center translation error of 0.96 ± 0.23 mm, an average maximum distance of 1.31 ± 0.20 mm, and an average angular deviation of 3.77 ± 0.85°. Experimental results demonstrated both the AR registration accuracy and the osteotomy accuracy of the developed system.


Assuntos
Realidade Aumentada , Osteotomia , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Osteotomia/métodos , Osteotomia/instrumentação , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Cirurgia Assistida por Computador/métodos , Acetábulo/cirurgia
3.
Surg Innov ; 31(1): 48-57, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38019844

RESUMO

BACKGROUND: Computer assisted surgical navigation systems are designed to improve outcomes by providing clinicians with procedural guidance information. The use of new technologies, such as mixed reality, offers the potential for more intuitive, efficient, and accurate procedural guidance. The goal of this study is to assess the positional accuracy and consistency of a clinical mixed reality system that utilizes commercially available wireless head-mounted displays (HMDs), custom software, and localization instruments. METHODS: Independent teams using the second-generation Microsoft HoloLens© hardware, Medivis SurgicalAR© software, and localization instruments, tested the accuracy of the combined system at different institutions, times, and locations. The ASTM F2554-18 consensus standard for computer-assisted surgical systems, as recognized by the U.S. FDA, was utilized to measure the performance. 288 tests were performed. RESULTS: The system demonstrated consistent results, with an average accuracy performance that was better than one millimeter (.75 ± SD .37 mm). CONCLUSION: Independently acquired positional tracking accuracies exceed conventional in-market surgical navigation tracking systems and FDA standards. Importantly, the performance was achieved at two different institutions, using an international testing standard, and with a system that included a commercially available off-the-shelf wireless head mounted display and software.


Assuntos
Realidade Aumentada , Cirurgia Assistida por Computador , Estados Unidos , Cirurgia Assistida por Computador/métodos , Sistemas de Navegação Cirúrgica , United States Food and Drug Administration , Software
4.
Arch Orthop Trauma Surg ; 144(3): 1077-1089, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38133802

RESUMO

INTRODUCTION: The periacetabular osteotomy is a technically demanding procedure with the goal to improve the osseous containment of the femoral head. The options for controlled execution of the osteotomies and verification of the acetabular reorientation are limited. With the assistance of augmented reality, new possibilities are emerging to guide this intervention. However, the scientific knowledge regarding AR navigation for PAO is sparse. METHODS: In this cadaveric study, we wanted to find out, if the execution of this complex procedure is feasible with AR guidance, quantify the accuracy of the execution of the three-dimensional plan, and find out what has to be done to proceed to real surgery. Therefore, an AR guidance for the PAO was developed and applied on 14 human hip cadavers. The guidance included performance of the four osteotomies and reorientation of the acetabular fragment. The osteotomy starting points, the orientation of the osteotomy planes, as well as the reorientation of the acetabular fragment were compared to the 3D planning. RESULTS: The mean 3D distance between planned and performed starting points was between 9 and 17 mm. The mean angle between planned and performed osteotomies was between 6° and 7°. The mean reorientation error between the planned and performed rotation of the acetabular fragment was between 2° and 11°. CONCLUSION: The planned correction can be achieved with promising accuracy and without serious errors. Further steps for a translation from the cadaver to the patient have been identified and must be addressed in future work.


Assuntos
Realidade Aumentada , Humanos , Estudos de Viabilidade , Acetábulo/cirurgia , Osteotomia/métodos , Cadáver
5.
Arch Orthop Trauma Surg ; 144(6): 2811-2821, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38704436

RESUMO

BACKGROUND: The use of portable navigation systems (PNS) in total hip arthroplasty (THA) has become increasingly prevalent, with second-generation PNS (sPNS) demonstrating superior accuracy in the lateral decubitus position compared to first-generation PNS. However, few studies have compared different types of sPNS. This study retrospectively compares the accuracy and clinical outcomes of two different types of sPNS instruments in patients undergoing THA. METHODS: A total of 158 eligible patients who underwent THA at a single institution between 2019 and 2022 were enrolled in the study, including 89 who used an accelerometer-based PNS with handheld infrared stereo cameras in the Naviswiss group (group N) and 69 who used an augmented reality (AR)-based PNS in the AR-Hip group (group A). Accuracy error, navigation error, clinical outcomes, and preparation time were compared between the two groups. RESULTS: Accuracy errors for Inclination were comparable between group N (3.5° ± 3.0°) and group A (3.5° ± 3.1°) (p = 0.92). Accuracy errors for anteversion were comparable between group N (4.1° ± 3.1°) and group A (4.5° ± 4.0°) (p = 0.57). The navigation errors for inclination (group N: 2.9° ± 2.7°, group A: 3.0° ± 3.2°) and anteversion (group N: 4.3° ± 3.5°, group A: 4.3° ± 4.1°) were comparable between the groups (p = 0.86 and 0.94, respectively). The preparation time was shorter in group A than in group N (p = 0.036). There were no significant differences in operative time (p = 0.255), intraoperative blood loss (p = 0.387), or complications (p = 0.248) between the two groups. CONCLUSION: An Accelerometer-based PNS using handheld infrared stereo cameras and AR-based PNS provide similar accuracy during THA in the lateral decubitus position, with a mean error of 3°-4° for both inclination and anteversion, though the AR-based PNS required a shorter preparation time.


Assuntos
Artroplastia de Quadril , Realidade Aumentada , Cirurgia Assistida por Computador , Sistemas de Navegação Cirúrgica , Humanos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação , Raios Infravermelhos
6.
BMC Oral Health ; 24(1): 88, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38229117

RESUMO

OBJECTIVE: The aim of this study was to present an innovative surgical protocol, navigation-based endoscopic enucleation (NBEE) for the treatment of large mandibular cystic lesions involving the mandibular ramus. METHODS: Twelve patients who presented with a large mandibular cystic lesion involving the mandibular ramus were enrolled in this study. Preoperative planning and intraoperative navigation were performed in all 12 patients. RESULTS: All patients in this study were treated with navigation-based endoscopic enucleation successfully. The follow-up period ranged from 7 to 10 months. Bone regenerated was found in all patients postoperatively. Three patients experienced temporary mandibular nerve palsy, and all relieved within 2 months. No pathological bone fracture was found during surgery. CONCLUSIONS: The use of navigation-based endoscopic enucleation (NBEE) for the treatment of large mandibular cystic lesions involving the ramus proved to be an effective method for complete and precise enucleation of the cystic lesion that also preserved the surrounding tissue.


Assuntos
Endoscopia , Mandíbula , Humanos , Mandíbula/cirurgia , Endoscopia/métodos , Osteotomia/métodos
7.
BMC Oral Health ; 24(1): 359, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38509530

RESUMO

This systematic review explores the accuracy of computerized guided implant placement including computer-aided static, dynamic, and robot-assisted surgery. An electronic search up to February 28, 2023, was conducted using the PubMed, Embase, and Scopus databases using the search terms "surgery", "computer-assisted", "dynamic computer-assisted", "robotic surgical procedures", and "dental implants". The outcome variables were discrepancies including the implant's 3D-coronal, -apical and -angular deviations. Articles were selectively retrieved according to the inclusion and exclusion criteria, and the data were quantitatively meta-analysed to verify the study outcomes. Sixty-seven articles were finally identified and included for analysis. The accuracy comparison revealed an overall mean deviation at the entry point of 1.11 mm (95% CI: 1.02-1.19), and 1.40 mm (95% CI: 1.31-1.49) at the apex, and the angulation was 3.51˚ (95% CI: 3.27-3.75). Amongst computerized guided implant placements, the robotic system tended to show the lowest deviation (0.81 mm in coronal deviation, 0.77 mm in apical deviation, and 1.71˚ in angular deviation). No significant differences were found between the arch type and flap operation in cases of dynamic navigation. The fully-guided protocol demonstrated a significantly higher level of accuracy compared to the pilot-guided protocol, but did not show any significant difference when compared to the partially guided protocol. The use of computerized technology clinically affirms that operators can accurately place implants in three directions. Several studies agree that a fully guided protocol is the gold standard in clinical practice.


Assuntos
Implantação Dentária Endóssea , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Implantação Dentária Endóssea/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Implantes Dentários , Ensaios Clínicos como Assunto
8.
Gen Dent ; 72(2): 60-64, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38411487

RESUMO

This case report presents a challenging case of catastrophic failure of a fixed partial denture involving fracture of the prosthesis as well as supporting implants and teeth. The use of robotics facilitated efficient and successful restoration of the patient's dentition. After extraction of 2 fractured teeth and 1 fractured implant, 2 new implants were placed with haptic guidance from robotics, which allowed for stable osteotomies and high initial implant stability quotients. Due to the patient's tremors and heavy occlusal forces, restoration was delayed to allow the surgical site to heal, and the patient received a provisional partial denture. With subsequent placement of the final restoration, the treatment was fully completed in 4.5 months and required only a single surgical procedure. The use of haptic robotics in this case allowed for accurate planning, spacing, and placement of screw-retained implants with an optimal arch, leading to the best long-term outcome for the patient.


Assuntos
Implantes Dentários , Robótica , Fraturas dos Dentes , Humanos , Força de Mordida , Parafusos Ósseos
9.
Minim Invasive Ther Allied Technol ; 33(3): 176-183, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38334755

RESUMO

INTRODUCTION: The use of laparoscopic and robotic liver surgery is increasing. However, it presents challenges such as limited field of view and organ deformations. Surgeons rely on laparoscopic ultrasound (LUS) for guidance, but mentally correlating ultrasound images with pre-operative volumes can be difficult. In this direction, surgical navigation systems are being developed to assist with intra-operative understanding. One approach is performing intra-operative ultrasound 3D reconstructions. The accuracy of these reconstructions depends on tracking the LUS probe. MATERIAL AND METHODS: This study evaluates the accuracy of LUS probe tracking and ultrasound 3D reconstruction using a hybrid tracking approach. The LUS probe is tracked from laparoscope images, while an optical tracker tracks the laparoscope. The accuracy of hybrid tracking is compared to full optical tracking using a dual-modality tool. Ultrasound 3D reconstruction accuracy is assessed on an abdominal phantom with CT transformed into the optical tracker's coordinate system. RESULTS: Hybrid tracking achieves a tracking error < 2 mm within 10 cm between the laparoscope and the LUS probe. The ultrasound reconstruction accuracy is approximately 2 mm. CONCLUSION: Hybrid tracking shows promising results that can meet the required navigation accuracy for laparoscopic liver surgery.


Assuntos
Imageamento Tridimensional , Laparoscopia , Fígado , Imagens de Fantasmas , Ultrassonografia , Laparoscopia/métodos , Humanos , Imageamento Tridimensional/métodos , Ultrassonografia/métodos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Cirurgia Assistida por Computador/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Sistemas de Navegação Cirúrgica , Laparoscópios
10.
Ann Surg Oncol ; 30(12): 7373-7383, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37606841

RESUMO

BACKGROUND: Laparoscopic anatomical Segment 8 (S8) resection is a highly challenging hepatectomy. Augmented reality navigation (ARN), which could be combined with indocyanine green (ICG) fluorescence imaging, has been applied in various complex liver resections and may also be applied in laparoscopic anatomical S8 resection. However, no study has explored how to apply ARN plus ICG fluorescence imaging (ARN-FI) in laparoscopic anatomical S8 resection, or explored its accuracy. PATIENTS AND METHODS: This study is a post hoc analysis that included 31 patients undergoing laparoscopic anatomical S8 resection from the clinical NaLLRFI trial, and the resected liver volume was measured in each patient. The perioperative parameters of safety and feasibility, as well as the accuracy analysis outcomes were compared. RESULTS: There were 16 patients in the ARN-FI group and 15 patients underwent conventional laparoscopic hepatectomy without ARN or fluorescence imaging (non-ARN-FI group). There was no significant difference in baseline characteristics between the two groups. Compared with the non-ARN-FI group, the ARN-FI group had lower intraoperative bleeding (median 125 vs. 300 mL, P = 0.003). No significant difference was observed in other postoperative short-term outcomes. Accuracy analysis indicated that the actual resected liver volume (ARLV) in the ARN-FI group was more accurate. CONCLUSIONS: ARN-FI was associated with less intraoperative bleeding and more accurate resection volume. These techniques may address existing challenges and provide rational guidance for laparoscopic anatomical S8 resection.

11.
Periodontol 2000 ; 91(1): 89-112, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35906928

RESUMO

Flapless and fully guided implant placement has the potential to maximize efficacy outcomes and at the same time to minimize surgical invasiveness. The aim of the current systematic review was to answer the following PICO question: "In adult human subjects undergoing dental implant placement (P), is minimally invasive flapless computer-aided fully guided (either dynamic or static computer-aided implant placement (sCAIP)) (I) superior to flapped conventional (free-handed implant placement (FHIP) or cast-based/drill partially guided implant placement (dPGIP)) surgery (C), in terms of efficacy, patient morbidity, long-term prognosis, and costs (O)?" Randomized clinical trials (RCTs) fulfilling specific inclusion criteria established to answer the PICO question were included. Two review authors independently searched for eligible studies, screened the titles and abstracts, performed full-text analysis, extracted the data from the published reports, and performed the risk of bias assessment. In cases of disagreement, a third review author took the final decision during ad hoc consensus meetings. The study results were summarized using random effects meta-analyses, which were based (wherever possible) on individual patient data (IPD). A total of 10 manuscripts reporting on five RCTs, involving a total of 124 participants and 449 implants, and comparing flapless sCAIP with flapped FHIP/cast-based partially guided implant placement (cPGIP), were included. There was no RCT analyzing flapless dynamic computer-aided implant placement (dCAIP) or flapped dPGIP. Intergroup meta-analyses indicated less depth deviation (difference in means (MD) = -0.28 mm; 95% confidence interval (CI): -0.59 to 0.03; moderate certainty), angular deviation (MD = -3.88 degrees; 95% CI: -7.00 to -0.77; high certainty), coronal (MD = -0.6 mm; 95% CI: -1.21 to 0.01; low certainty) and apical (MD = -0.75 mm; 95% CI: -1.43 to -0.07; moderate certainty) three-dimensional bodily deviations, postoperative pain (MD = -17.09 mm on the visual analogue scale (VAS); 95% CI: -33.38 to -0.80; low certainty), postoperative swelling (MD = -6.59 mm on the VAS; 95% CI: -19.03 to 5.85; very low certainty), intraoperative discomfort (MD = -9.36 mm on the VAS; 95% CI: -17.10 to -1.61) and surgery duration (MD = -24.28 minutes; 95% CI: -28.62 to -19.95) in flapless sCAIP than in flapped FHIP/cPGIP. Despite being more accurate than flapped FHIP/cPGIP, flapless sCAIP still resulted in deviations with respect to the planned position (intragroup meta-analytic means: 0.76 mm in depth, 2.57 degrees in angular, 1.43 mm in coronal, and 1.68 in apical three-dimensional bodily position). Moreover, flapless sCAIP presented a 12% group-specific intraoperative complication rate, resulting in an inability to place the implant with this protocol in 7% of cases. Evidence regarding more clinically relevant outcomes of efficacy (implant survival and success, prosthetically and biologically correct positioning), long-term prognosis, and costs, is currently scarce. When the objective is to guarantee minimal invasiveness at implant placement, clinicians could consider the use of flapless sCAIP. A proper case selection and consideration of a safety margin are, however, suggested.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Adulto , Humanos , Implantação Dentária Endóssea/métodos , Retalhos Cirúrgicos
12.
Surg Endosc ; 37(10): 8156-8164, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37653158

RESUMO

BACKGROUND: Right hemi-hepatectomy plus total caudate lobectomy is the appropriate procedure for type IIIa or partial type II pCCA. However, the laparoscopic implementation of this procedure remains technically challenging, especially hilar vascular dissection and en bloc resection of the total caudate lobe. Augmented reality navigation can provide intraoperative navigation to enhance visualization of invisible hilar blood vessels and guide the parenchymal transection plane. METHODS: Eleven patients who underwent laparoscopic right hemi-hepatectomy plus total caudate lobectomy from January 2021 to January 2023 were enrolled in this study. Augmented reality navigation technology and the anterior approach were utilized in this operation. Routine operative and short-term postoperative outcomes were assessed to evaluate the feasibility of the novel navigation method in this operation. RESULTS: Right hemi-hepatectomy plus total caudate lobectomy was successfully performed in all 11 enrolled patients. Among the 11 patients, the mean operation time was 454.5 ± 25.0 min and the mean estimated blood loss was 209.1 ± 56.1 ml. Negative surgical margins were achieved in all patients. The postoperative course of all the patients was uneventful, and the mean length of postoperative hospital stay was 10.5 ± 1.2 days. CONCLUSION: Laparoscopic right hemi-hepatectomy plus total caudate lobectomy via the anterior approach may be feasible and safe for pCCA with the assistance of augmented reality navigation.


Assuntos
Realidade Aumentada , Neoplasias dos Ductos Biliares , Colangiocarcinoma , Tumor de Klatskin , Laparoscopia , Neoplasias Hepáticas , Humanos , Tumor de Klatskin/cirurgia , Hepatectomia/métodos , Estudos de Viabilidade , Neoplasias Hepáticas/cirurgia , Laparoscopia/métodos , Neoplasias dos Ductos Biliares/cirurgia , Neoplasias dos Ductos Biliares/patologia , Colangiocarcinoma/cirurgia
13.
Surg Endosc ; 37(9): 7083-7099, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37386254

RESUMO

BACKGROUND: Surgical process model (SPM) analysis is a great means to predict the surgical steps in a procedure as well as to predict the potential impact of new technologies. Especially in complicated and high-volume treatments, such as parenchyma sparing laparoscopic liver resection (LLR), profound process knowledge is essential for enabling improving surgical quality and efficiency. METHODS: Videos of thirteen parenchyma sparing LLR were analyzed to extract the duration and sequence of surgical steps according to the process model. The videos were categorized into three groups, based on the tumor locations. Next, a detailed discrete events simulation model (DESM) of LLR was built, based on the process model and the process data obtained from the endoscopic videos. Furthermore, the impact of using a navigation platform on the total duration of the LLR was studied with the simulation model by assessing three different scenarios: (i) no navigation platform, (ii) conservative positive effect, and (iii) optimistic positive effect. RESULTS: The possible variations of sequences of surgical steps in performing parenchyma sparing depending on the tumor locations were established. The statistically most probable chain of surgical steps was predicted, which could be used to improve parenchyma sparing surgeries. In all three categories (i-iii) the treatment phase covered the major part (~ 40%) of the total procedure duration (bottleneck). The simulation results predict that a navigation platform could decrease the total surgery duration by up to 30%. CONCLUSION: This study showed a DESM based on the analysis of steps during surgical procedures can be used to predict the impact of new technology. SPMs can be used to detect, e.g., the most probable workflow paths which enables predicting next surgical steps, improving surgical training systems, and analyzing surgical performance. Moreover, it provides insight into the points for improvement and bottlenecks in the surgical process.


Assuntos
Laparoscopia , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/cirurgia , Hepatectomia/métodos , Laparoscopia/métodos , Tempo de Internação
14.
Clin Oral Implants Res ; 34(5): 438-449, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36794798

RESUMO

OBJECTIVES: To assess dental implant placement accuracy with a dynamic computer-assisted implant surgery (dCAIS) system and a freehand approach. Secondarily, to compare the patients' perception and quality of life (QoL) with the two approaches. METHODS: A double-arm randomized clinical trial was conducted. Consecutive partially edentulous patients were randomly allocated to the dCAIS or standard freehand approach groups. Implant placement accuracy was evaluated by overlapping the preoperative and postoperative Cone Beam Computer Tomographs (CBCT) and recording linear deviations at the implant apex and platform (in mm) and angular deviations (in degrees). Questionnaires recorded self-reported satisfaction, pain and QoL during surgery and postoperatively. RESULTS: Thirty patients (22 implants) were enrolled in each group. One patient was lost to follow-up. A significant difference (p < .001) in mean angular deviation was found between the dCAIS (4.02°; 95% CI: 2.85 to 5.19) and the FH (7.97°; 95% CI: 5.36 to 10.58) groups. Linear deviations were significantly lower in the dCAIS group, except for the apex vertical deviation, where no differences were found. Although dCAIS took 14 min longer (95% CI: 6.43 to 21.24; p < .001), patients in both groups considered the surgical time acceptable. Postoperative pain and analgesic consumption during the first postoperative week were similar between groups and self-reported satisfaction was very high. CONCLUSION: dCAIS systems significantly increase the accuracy of implant placement in partially edentulous patients in comparison with the conventional freehand approach. However, they increase the surgical time significantly and do not seem to improve patient satisfaction or reduce postoperative pain.


Assuntos
Implantes Dentários , Boca Edêntula , Cirurgia Assistida por Computador , Humanos , Qualidade de Vida , Implantação Dentária Endóssea , Tomografia Computadorizada de Feixe Cônico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Desenho Assistido por Computador , Imageamento Tridimensional
15.
Eur Spine J ; 32(10): 3425-3433, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37552327

RESUMO

PURPOSE: Over the last years, interest and efforts to implement augmented reality (AR) in orthopedic surgery through head-mounted devices (HMD) have increased. However, the majority of experiments were preclinical and within a controlled laboratory environment. The operating room (OR) is a more challenging environment with various confounding factors potentially affecting the performance of an AR-HMD. The aim of this study was to assess the performance of an AR-HMD in a real-life OR setting. METHODS: An established AR application using the HoloLens 2 HMD was tested in an OR and in a laboratory by two users. The accuracy of the hologram overlay, the time to complete the trial, the number of rejected registration attempts, the delay in live overlay of the hologram, and the number of completely failed runs were recorded. Further, different OR setting parameters (light condition, setting up partitions, movement of personnel, and anchor placement) were modified and compared. RESULTS: Time for full registration was higher with 48 s (IQR 24 s) in the OR versus 33 s (IQR 10 s) in the laboratory setting (p < 0.001). The other investigated parameters didn't differ significantly if an optimal OR setting was used. Within the OR, the strongest influence on performance of the AR-HMD was different light conditions with direct light illumination on the situs being the least favorable. CONCLUSION: AR-HMDs are affected by different OR setups. Standardization measures for better AR-HMD performance include avoiding direct light illumination on the situs, setting up partitions, and minimizing the movement of personnel.


Assuntos
Realidade Aumentada , Humanos , Salas Cirúrgicas
16.
Nanomedicine ; 50: 102671, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37054805

RESUMO

OBJECTIVE: Perineural invasion (PNI) is associated with local recurrence, distant metastasis, and a poor prognosis in pancreatic cancer. However, rare attempt was made to identified the PNI intraoperative. To facilitate precise R0 excision of the tumor, we planned to develop a fluorescent probe for intraoperative imaging of the PNI using GAP-43 as the target and indocyanine green (ICG) as the carrier. METHODS: The probe was created by binding peptide antibody and ICG. Its targeting was tested in vitro and in vivo using a co-culture model of PC12 and tumor cells to create an in vitro neural invasion model and a mouse sciatic nerve invasion model. The small animal imaging system and surgical navigation system confirmed the probe's potential clinical applicability. The sciatic nerve damage model was created to confirm the probe's targeting. RESULTS: We used the pancreatic cancer samples and the public database to confirm that GAP-43 was preferentially overexpressed in pancreatic cancer, particularly in PNI. PC12 cells showed high GAP-43RA-PEG-ICG probe-specific absorption after being co-cultured with tumor cells in vitro. In the sciatic nerve invasion experiment, animals in probe group displayed a significantly stronger fluorescence signal at the PNI compared to ICG-NP and the contralateral normal nerves groups. Although only 60 % of mice appeared to have R0 resections by the naked eye, small animal imaging systems and surgical fluorescence navigation systems could remove the tumor with R0 precision. The injury model used in the probe imaging experimental trials demonstrated that the probe was specifically targeted to the injured nerve, regardless of whether the injury was infiltrated by a tumor or physical. CONCLUSION: We developed the GAP-43Ra-ICG-PEG, an active-targeting near-infrared fluorescent (NIRF) probe, that specifically binds to GAP-43-positive neural cells in an in vitro model of PNI. The probe efficiently visualized PNI lesions in pancreatic cancer in preclinical models, opening up new possibilities for NIRF-guided pancreatic surgery, particularly for PNI patients.


Assuntos
Verde de Indocianina , Neoplasias Pancreáticas , Ratos , Camundongos , Animais , Corantes Fluorescentes , Proteína GAP-43 , Neoplasias Pancreáticas/patologia , Modelos Animais de Doenças , Neoplasias Pancreáticas
17.
J Arthroplasty ; 38(6S): S374-S378, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36828051

RESUMO

BACKGROUND: The accuracy, precision, and repeatability by which the tibial sagittal plane can be found with imageless technology is currently unknown. The purpose of this study was to identify any differences between imageless and image-based technology to define the sagittal plane of the tibia. METHODS: A computed tomography (CT) was obtained of 18 cadavers with the knee fully extended. The surgical trans-epicondylar axis and several tibial rotation references were acquired on the CT scan. After a medial parapatellar approach, the same anatomical landmarks were acquired in vivo. In the horizontal plane, the angle between the surgical trans-epicondylar axis and the tibial rotational axes was assessed. RESULTS: Highest accuracy was found for posterior cruciate ligament (PCL)-anterior cruciate ligament (ACL, -1.48°, standard deviation [SD] 13.64; imageless), tibial medial condyle (TMC)-tibial lateral condyle (TLC, 1.72°, SD 4.24; image-based), the ACL-medial border of tibial tuberosity (MTT, -2.89°, SD 18.86; image-based). Highest precision was acquired with image-based technology: TMC-TLC (SD 4.24), PCL-ACL (SD 5.86), and PCL-medial third of tibial tuberosity (M3TT, SD 7.10). Excellent intraobserver and interobserver correlation coefficients were observed with image-based technology: PCL-MTT, anterior medial condyle (AMC)-anterior lateral condyle (ALC), and TMC-TLC (Intraobserver and interobserver correlation coefficients 0.90-0.98). CONCLUSION: The tibial sagittal plane could be defined with highest accuracy, precision, and repeatability on a preoperative CT. Imageless methodology lacked the precision and repeatability of image-based technology. With the current pursuit of high accuracy and precision in total knee arthroplasty, the reference frame used to quantify implant position should be highly accurate and precise as well. LEVEL OF EVIDENCE: IV, Case Series.


Assuntos
Ligamento Cruzado Posterior , Tíbia , Humanos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Ligamento Cruzado Anterior/cirurgia , Cadáver
18.
Sensors (Basel) ; 23(10)2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37430734

RESUMO

We are developing a transmission-based probe for point-of-care assessment of vertebrae strength needed for fabricating the instrumentation used in supporting the spinal column during spinal fusion surgery. The device is based on a transmission probe whereby thin coaxial probes are inserted into the small canals through the pedicles and into the vertebrae, and a broad band signal is transmitted from one probe to the other across the bone tissue. Simultaneously, a machine vision scheme has been developed to measure the separation distance between the probe tips while they are inserted into the vertebrae. The latter technique includes a small camera mounted to the handle of one probe and associated fiducials printed on the other. Machine vision techniques make it possible to track the location of the fiducial-based probe tip and compare it to the fixed coordinate location of the camera-based probe tip. The combination of the two methods allows for straightforward calculation of tissue characteristics by exploiting the antenna far field approximation. Validation tests of the two concepts are presented as a precursor to clinical prototype development.


Assuntos
Osso e Ossos , Coluna Vertebral , Sistemas Automatizados de Assistência Junto ao Leito
19.
Sensors (Basel) ; 23(24)2023 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-38139718

RESUMO

Medical image analysis forms the basis of image-guided surgery (IGS) and many of its fundamental tasks. Driven by the growing number of medical imaging modalities, the research community of medical imaging has developed methods and achieved functionality breakthroughs. However, with the overwhelming pool of information in the literature, it has become increasingly challenging for researchers to extract context-relevant information for specific applications, especially when many widely used methods exist in a variety of versions optimized for their respective application domains. By being further equipped with sophisticated three-dimensional (3D) medical image visualization and digital reality technology, medical experts could enhance their performance capabilities in IGS by multiple folds. The goal of this narrative review is to organize the key components of IGS in the aspects of medical image processing and visualization with a new perspective and insights. The literature search was conducted using mainstream academic search engines with a combination of keywords relevant to the field up until mid-2022. This survey systemically summarizes the basic, mainstream, and state-of-the-art medical image processing methods as well as how visualization technology like augmented/mixed/virtual reality (AR/MR/VR) are enhancing performance in IGS. Further, we hope that this survey will shed some light on the future of IGS in the face of challenges and opportunities for the research directions of medical image processing and visualization.


Assuntos
Realidade Aumentada , Cirurgia Assistida por Computador , Realidade Virtual , Cirurgia Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador
20.
IEEE Trans Robot ; 39(6): 4500-4519, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38249319

RESUMO

Aortic valve surgery is the preferred procedure for replacing a damaged valve with an artificial one. The ValveTech robotic platform comprises a flexible articulated manipulator and surgical interface supporting the effective delivery of an artificial valve by teleoperation and endoscopic vision. This article presents our recent work on force-perceptive, safe, semiautonomous navigation of the ValveTech platform prior to valve implantation. First, we present a force observer that transfers forces from the manipulator body and tip to a haptic interface. Second, we demonstrate how hybrid forward/inverse mechanics, together with endoscopic visual servoing, lead to autonomous valve positioning. Benchtop experiments and an artificial phantom quantify the performance of the developed robot controller and navigator. Valves can be autonomously delivered with a 2.0±0.5 mm position error and a minimal misalignment of 3.4±0.9°. The hybrid force/shape observer (FSO) algorithm was able to predict distributed external forces on the articulated manipulator body with an average error of 0.09 N. FSO can also estimate loads on the tip with an average accuracy of 3.3%. The presented system can lead to better patient care, delivery outcome, and surgeon comfort during aortic valve surgery, without requiring sensorization of the robot tip, and therefore obviating miniaturization constraints.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA