Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 140
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Skeletal Radiol ; 53(4): 811-816, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37665347

RESUMO

Targeted muscle reinnervation (TMR) was originally developed as a means for increasing intuitive prosthesis control, though later found to play a role in phantom limb pain and neuroma prevention. There is a paucity of literature describing the clinical course of patients with poor TMR surgical outcomes and the value of imaging in the postoperative recovery period. This report will illustrate the potential utility of ultrasound neurography to accurately differentiate TMR surgical outcomes in two patients that received upper extremity amputation and subsequent reconstruction with TMR. Ultrasound evaluation of TMR sites in patient 1 confirmed successful reinnervation, evident by nerve fascicle continuity and eventual integration of the transferred nerve into the target muscle. Conversely, the ultrasound of patient 2 showed discontinuity of the nerve fascicles, neuroma formation, and muscle atrophy in all three sites of nerve transfer, suggesting an unsuccessful procedure and poor functional recovery. Ultrasound neurography is uniquely able to capture the longitudinal trajectory of rerouted nerves to confirm continuity and eventual reinnervation into muscle. Therefore, the application of ultrasound in a postoperative setting can correctly identify instances of failed TMR before this information would become available through clinical evaluation. Early identification of poor TMR outcomes may benefit future patients by fostering the discovery of failure mechanisms and aiding in further surgical planning to improve functional outcomes.


Assuntos
Transferência de Nervo , Neuroma , Membro Fantasma , Humanos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/cirurgia , Músculo Esquelético/inervação , Amputação Cirúrgica , Membro Fantasma/prevenção & controle , Membro Fantasma/cirurgia , Transferência de Nervo/métodos
2.
J Dairy Sci ; 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39122152

RESUMO

The objective of this study was to examine the impact of stage of lactation (early, mid and late) and proportion of pasture in the cows diet (high: GRS, medium: PMR and no: TMR) on the composition and quality of Cheddar cheese. Triplicate trials were carried out in each stage of lactation, and milk protein and fat contents were standardized for Cheddar cheese manufacture at pilot scale. As cheese milks were standardized for milk fat and protein contents, gross composition did not differ as a result of diet. Fatty acid profiles of GRS cheese were significantly different from TMR, while PMR profiles were less distinct and more similar to both GRS and TMR profiles, as illustrated by partial least squares discriminatory analysis. Fatty acids including CLA C18:2 cis-9, trans-11, C22:1 n-9 and C18:3 n-3 were most influential in this separation of profiles. Fatty acid profiling revealed that GRS derived cheese contained higher proportions of nutrients considered beneficial for human health including higher proportions of unsaturated fatty acids and omega-3 fatty acids. A biomarker model utilizing the proportions of 5 fatty acids was constructed and was effective at distinguishing between cheese of GRS, TMR and PMR feeding systems. Proportions of ρ-κ-casein, αs2-casein and αs1-casein in cheese also differed between diets while proportions of ρ-κ-casein, αs1-casein and ß-casein were lowest in late lactation cheese. The impact of diet was less influential compared with that of stage of lactation on the ripening characteristics of cheese. An index of primary proteolysis was highest in late lactation cheese. The peptides derived from the proteolysis of κ-casein and ß-casein and levels of secondary proteolysis, in particular, the proportions of 12 free amino acids were most influenced by stage of lactation. Overall this study demonstrated the effects of increasing pasture allowance and stage of lactation on the nutritional quality and ripening properties of Cheddar cheese.

3.
Sensors (Basel) ; 24(2)2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38257481

RESUMO

This paper proposes a non-contact current measurement method for three-phase rectangular busbars based on TMR (tunneling magneto-resistance) sensors, due to their advantages of large dynamic range, wide bandwidth, light weight, and easy installation. A non-contact current sensor composed of only three TMR sensors is developed and the TMR sensors are respectively placed at a location with a certain distance from the surface of each rectangular busbar to measure the magnetic fields generated by the busbar currents. To calibrate the developed current sensor, i.e., to establish the relationship between the magnetic fields measured by the TMR sensors and the currents flowing in the three-phase rectangular busbars, we designed a thyristor-controlled resistive load as a calibrator, which is connected to a downstream branch of the distribution cabinet. By switching the resistive load, a calibration current, which can be identified from the background current, is generated in one rectangular busbar and its value is measured at the location of the calibrator, and transmitted wirelessly to the location of the TMR sensors. A new and robust method is proposed to extract the voltage components, corresponding to the calibration current, from the voltage waveforms of the TMR sensors. By calculating the proportional coefficients between the calibration currents and the extracted voltage components, online calibration of the current sensor is achieved. We designed and implemented a current measurement system consisting of a current sensor using TMR sensors, a thyristor-controlled resistive load for current sensor calibration, and a data acquisition circuit based on a multi-channel analog-to-digital converter (ADC). Current measurement experiments were performed in a practical distribution cabinet installed in our laboratory. Compared to the measurement results using a commercial current probe with an accuracy of 1%, the relative error of the measured currents in RMS is less than 2.5% and the phase error is less than 1°, while the nonlinearity error of the current sensor is better than 0.8%.

4.
Sensors (Basel) ; 24(11)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38894055

RESUMO

Ferromagnetic pipes are widely used in the oil and gas industry. They are subject to cracks due to corrosion, pressure, and fatigue. It is significant to detect cracks for the safety of pipes. A residual magnetic field testing (RMFT) system is developed for crack detection in ferromagnetic pipes. Based on this background, a detection probe based on an array of tunneling magneto-resistive (TMR) sensors and permanent magnets is exploited. The probe is able to partially magnetize the pipe wall and collect magnetic signals simultaneously. First, a theoretical analysis of RMFT is presented. The physics principle of RMFT is introduced, and a finite element model is built. In the finite element simulations, the effects of the crack length and depth on the RMFT signal are analyzed, and the signal characteristics are selected to represent the crack size. Next, the validated experiments are conducted to demonstrate the feasibility of the proposed RMFT method in this paper.

5.
Trop Anim Health Prod ; 56(3): 124, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38613629

RESUMO

The study aimed to assess the impact of feeding Bengal gram residual forage-based pelleted Total Mixed Ration (TMR) with varying concentrate (C) to roughage (R) ratios on feed intake, nutrient utilization, growth, and carcass characteristics in Barbari kids. Sixteen weaned male Barbari kids (av. age, 233 ± 11 days; weight, 13.86 ± 0.76 kg) were divided into two groups (T1 and T2), each receiving different pelleted diets (TMR) with distinct concentrate to roughage ratios (T1 with 60:40; T2 with 40:60). The kids were fed for 133 days, and a digestion trial was conducted at the end of the study. After completion, all kids were slaughtered. Although, kids under T1 consumed higher (P < 0.001) amount of dry matter, and crude protein compared to T2, which was due to a higher concentrate to roughage ratio in T1. But, the average daily body weight gain (ADG) of finisher kids was 88.53, and 79.83 g/d/kid in T1 and T2, respectively; however, the difference was non-significant. Digestibility of organic matter, crude protein, and total carbohydrate was also greater in T1 compared to T2. Total digestible nutrients intake was higher (P < 0.001) in T1; similarly intake of digestible energy, and metabolizable energy were significantly increased (P < 0.01) in T1 compared to T2. Concentrations of volatile fatty acids and NH3-nitrogen were also enhanced (P < 0.05) in T1 compared to T2. We observed similar carcass weight, and dressing percentage in both groups, and carcass composition remained unaffected. The pelleted diet containing greater ratio of concentrate: roughage (60:40) had no additional benefits in terms of ADG, and carcass traits in finisher kids. Therefore, it may be concluded that the Bengal gram residual forage-based pelleted TMR diet containing C40: R60 (TDN 57.13%, DCP 7.64%, ME 9.11MJ/kg feed) is suitable for optimizing growth performance with desirable carcass traits, and meat composition in finisher Barbari kids reared under the intensive system.


Assuntos
Fibras na Dieta , Nutrientes , Masculino , Animais , Fenótipo , Sorogrupo , Ingestão de Alimentos
6.
Can J Neurol Sci ; : 1-6, 2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37489506

RESUMO

BACKGROUND: Causalgia and complex regional pain syndrome (CRPS) type II with nerve injury can be difficult to treat. Surgical peripheral nerve denervation for causalgia has been largely abandoned by pain clinicians because of a perception that this may aggravate a central component (anesthesia dolorosa). METHODS: We selectively searched Pubmed, Cochrane, MEDLINE, EMBASE, CINAHL Plus, and Scopus from 1947 for articles, books, and book chapters for evidence of surgical treatments (nerve resection and amputation) and treatment related to autoimmunity and immune deficiency with CRPS. RESULTS: Reviews were found for the treatment of causalgia or CRPS type II (n = 6), causalgia relieved by nerve resection (n = 6), and causalgia and CRPS II treated by amputation (n = 8). Twelve reports were found of autoimmunity with CRPS, one paper of these on associated immune deficiency and autoimmunity, and two were chosen for discussion regarding treatment with immunoglobulin and one by plasma exchange. We document a report of a detailed and unique pathological examination of a CRPS type II affected amputated limb and related successful treatment with immunoglobulin. CONCLUSIONS: Nerve resection, with grafting, and relocation may relieve uncomplicated causalgia and CRPS type II in some patients in the long term. However, an unrecognized and treatable immunological condition may underly some CRPS II cases and can lead to the ultimate failure of surgical treatments.

7.
Sensors (Basel) ; 23(23)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38067880

RESUMO

This paper proposes a flexible eddy current TMR (FEC-TMR) sensor to monitor the internal crack of metal joint structures. First, the finite element model of the FEC-TMR sensor is established to analyze the influence of the sensor's crack identification sensitivity with internal crack propagation at different depths and determine the optimal location and exciting frequency of the sensor. Then, the optimal longitudinal spacing and exciting frequency of the sensor are tested by experiment. The experimental results are consistent with the simulation results, which verify the correctness of the simulation model. Finally, the experiment is carried out for internal cracks of different depths to verify that the sensor can monitor internal cracks, and the crack identification sensitivity gradually decreases with the increase in the depth of the crack from the surface.

8.
Sensors (Basel) ; 23(8)2023 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-37112169

RESUMO

The status of zinc oxide (ZnO) arresters is directly related to the safety of power grids. However, as the service life of ZnO arresters increases, their insulation performance may decrease due to factors such as operating voltage and humidity, which can be identified through the measurement of leakage current. Tunnel magnetoresistance (TMR) sensors with high sensitivity, good temperature stability, and small size are excellent for measuring leakage current. This paper constructs a simulation model of the arrester and investigates the deployment of the TMR current sensor and the size of the magnetic concentrating ring. The arrester's leakage current magnetic field distribution under different operating conditions is simulated. The simulation model can aid in optimizing the detection of leakage current in arresters using TMR current sensors, and the findings serve as a basis for monitoring the condition of arresters and improving the installation of current sensors. The TMR current sensor design offers potential advantages such as high accuracy, miniaturization, and ease of distributed application measurement, making it suitable for large-scale use. Finally, the validity of the simulations and conclusions is verified through experiments.

9.
Sensors (Basel) ; 23(2)2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36679442

RESUMO

A magnetocardiograph that enables the clear observation of heart magnetic field mappings without magnetically shielded rooms at room temperatures has been successfully manufactured. Compared to widespread electrocardiographs, magnetocardiographs commonly have a higher spatial resolution, which is expected to lead to early diagnoses of ischemic heart disease and high diagnostic accuracy of ventricular arrhythmia, which involves the risk of sudden death. However, as the conventional superconducting quantum interference device (SQUID) magnetocardiographs require large magnetically shielded rooms and huge running costs to cool the SQUID sensors, magnetocardiography is still unfamiliar technology. Here, in order to achieve the heart field detectivity of 1.0 pT without magnetically shielded rooms and enough magnetocardiography accuracy, we aimed to improve the detectivity of tunneling magnetoresistance (TMR) sensors and to decrease the environmental and sensor noises with a mathematical algorithm. The magnetic detectivity of the TMR sensors was confirmed to be 14.1 pTrms on average in the frequency band between 0.2 and 100 Hz in uncooled states, thanks to the original multilayer structure and the innovative pattern of free layers. By constructing a sensor array using 288 TMR sensors and applying the mathematical magnetic shield technology of signal space separation (SSS), we confirmed that SSS reduces the environmental magnetic noise by -73 dB, which overtakes the general triple magnetically shielded rooms. Moreover, applying digital processing that combined the signal average of heart magnetic fields for one minute and the projection operation, we succeeded in reducing the sensor noise by about -23 dB. The heart magnetic field resolution measured on a subject in a laboratory in an office building was 0.99 pTrms and obtained magnetocardiograms and current arrow maps as clear as the SQUID magnetocardiograph does in the QRS and ST segments. Upon utilizing its superior spatial resolution, this magnetocardiograph has the potential to be an important tool for the early diagnosis of ischemic heart disease and the risk management of sudden death triggered by ventricular arrhythmia.


Assuntos
Magnetocardiografia , Isquemia Miocárdica , Humanos , Coração , Arritmias Cardíacas/diagnóstico , Morte Súbita
10.
Anaerobe ; 73: 102508, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34974183

RESUMO

Coconut coir (a lignin-rich, organic material) is widely used for its commercial and economic benefits. In this study, crossbred (exotic) and Kankrej (indigenous) breeds of cattle were fed diets containing 7 or 14% coconut coir. Metagenomic analyses (16S rRNA gene amplicon and shotgun sequencing) were used to characterize the microbial community in the rumen and fecal samples along with their functional capabilities. Both amplicon and shotgun analyses revealed the predominance of bacterial phyla, Bacteroidetes, Firmicutes, Actinobacteria and Fibrobacter in ruminal liquid, ruminal solid and fecal samples. 16S rRNA gene amplicon sequencing revealed a total of 18 different bacterial taxa were found to be enriched exclusively in the animals fed with 14% coir. The shotgun analysis revealed abundance of bacterial genera, Fibrobacter, Clostridium, Prevotella, Butyrivibrio, and Ruminococcus in both liquid and solid fractions of ruminal contents, while in the fecal sample, Bacteroides, Alistipes, Plaudibacter, Parabacteroides, Porphyromonas, and Victivallis and archaeal genus, Methanocorpusculum were abundant. The functional analysis based on dbCAN database suggested that among the Glycoside hydrolase family, genes that encode oligosaccharide degrading enzymes, GH3, GH13 (p-value < 0.05), and GH43 were abundant in the feces. In ruminal solid, cellulase encoding the GH5 family was abundant. Also, lignocellulosic binding modules encoded by the CBM family, including cellulose (CBM3) and hemicellulose binding modules (CBM32 and CBM67) were abundant. Thus, the study indicated the enrichment of lignocellulosic enzymes in ruminal contents in response to feeding the coconut coir, which could be mined for potential biofuel production and other biotechnological applications.


Assuntos
Metagenoma , Rúmen , Animais , Bovinos , Dieta/veterinária , Fezes , Lignina , RNA Ribossômico 16S/genética , Rúmen/microbiologia
11.
Sensors (Basel) ; 22(24)2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36560218

RESUMO

A pattern-recognition (PR)-based myoelectric control system is the trend of future prostheses development. Compared with conventional prosthetic control systems, PR-based control systems provide high dexterity, with many studies achieving >95% accuracy in the last two decades. However, most research studies have been conducted in the laboratory. There is limited research investigating how EMG signals are acquired when users operate PR-based systems in their home and community environments. This study compares the statistical properties of surface electromyography (sEMG) signals used to calibrate prostheses and quantifies the quality of calibration sEMG data through separability indices, repeatability indices, and correlation coefficients in home and laboratory settings. The results demonstrate no significant differences in classification performance between home and laboratory environments in within-calibration classification error (home: 6.33 ± 2.13%, laboratory: 7.57 ± 3.44%). However, between-calibration classification errors (home: 40.61 ± 9.19%, laboratory: 44.98 ± 12.15%) were statistically different. Furthermore, the difference in all statistical properties of sEMG signals is significant (p < 0.05). Separability indices reveal that motion classes are more diverse in the home setting. In summary, differences in sEMG signals generated between home and laboratory only affect between-calibration performance.


Assuntos
Membros Artificiais , Eletromiografia/métodos , Movimento (Física) , Músculos , Reconhecimento Automatizado de Padrão/métodos
12.
Sensors (Basel) ; 22(3)2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35161769

RESUMO

Tunnel magnetoresistance (TMR) is a kind of magnetic sensor with the advantages of low cost and high sensitivity. For ultra-weak and low-frequency magnetic field measurement, the TMR sensor is affected by the 1/f noise. This paper proposes an AC modulation method with impedance compensation to improve the performance. The DC and AC characteristics of the sensors were measured and are presented here. It was found that both the equivalent resistance and capacitor of the sensors are affected by the external magnetic field. The TMR sensors are connected as a push-pull bridge circuit to measure the magnetic field. To reduce the common-mode noise, two similar bridge circuits form a magnetic gradiometer. Experimental results show that the sensor's sensitivity in the low-frequency range is obviously improved by the modulation and impedance compensation. The signal-to-noise ratio of the sensor at 1 Hz was increased about 25.3 dB by the AC modulation, impedance compensation, and gradiometer measurement setup. In addition, the sensitivity of the sensor was improved from 165.2 to 222.1 mV/V/mT. Ultra-weak magnetic signals, namely magnetocardiography signals of two human bodies, were measured by the sensor in an unshielded environment. It was seen that the R peak of MCG can be clearly visualized from the recorded signal.

13.
J Dairy Sci ; 104(5): 5405-5416, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33612209

RESUMO

This study aimed to evaluate the effects of organic acid (OA; Mold-Zap, Alltech, Nicholasville, KY) inclusion in the total mixed ration (TMR) and feeding frequency of TMR for lactating dairy cows on intake, total-tract apparent digestibility, sorting index, feeding behavior, ruminal fermentation, milk yield and composition, nitrogen balance, and serum metabolites. Twenty-four lactating Holstein cows, 4 with rumen cannulas, with (mean ± standard error) 247 ± 22.2 d in milk, 672 ± 14.6 kg of body weight, and 31.1 ± 1.09 kg of milk yield at the beginning of the experiment were used. The cows were distributed in a balanced and contemporary 4 × 4 Latin square experimental design and randomly assigned in a 2 × 2 factorial arrangement to evaluate OA [0 (OA-) or 0.5 (OA+) L of Mold-Zap/tonne of TMR on a natural matter basis] and feeding frequency of TMR offered once a day (1×) or twice a day (2×). Each experimental period lasted 21 d, with 14 d for acclimation and 7 d for data collection. The treatments were tested for TMR, in which its temperature was recorded every 2 h through a 24-h period in each experimental period. Organic acid-treated TMR showed a lower temperature during the 24-h period compared with nontreated TMR. The OA and feeding frequency had no effect on intake and total-tract apparent digestibility of dry matter and nutrients, aside from a tendency to increase neutral detergent fiber digestibility in cows fed 2×. Also, cows fed 1× tended to select more particles between 19 and 8 mm and refused particles smaller than 4 mm, whereas cows fed OA tended to select more particles smaller than 4 mm. Cows fed OA had greater milk yield and milk protein and lactose yields, but tended to have higher 3.5% fat-corrected milk yield. Neither treatment influenced ruminal and serum variables nor milk fat yield and milk production efficiency. Cows fed OA spent less time idling and tended to have lower rumination time, and tended to have higher time spent drinking water and eating, whereas animals fed 1× spent more time drinking water. Under the conditions of this experiment, we conclude that it was possible to reduce the feeding frequency of TMR, without negative effects on dairy cow performance. However, the use of OA resulted in higher milk yield and mitigated TMR temperature rise regardless of feeding frequency. The effect of external factors such as collective stimulation of intake and stage of lactation on feeding frequency effect must be surveyed in further research.


Assuntos
Lactação , Rúmen , Ração Animal/análise , Animais , Bovinos , Dieta/veterinária , Digestão , Feminino , Fermentação , Leite , Rúmen/metabolismo
14.
Clin Oral Investig ; 25(9): 5375-5390, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33891172

RESUMO

OBJECTIVES: Dental caries is closely associated with acid-producing bacteria, and Streptococcus mutans is one of the primary etiological agents. Bacterial accumulation and dental demineralization lead to destruction of bonding interface, thus limiting the longevity of composite. The present study investigated remineralization effectiveness of adhesive containing nanoparticles of amorphous calcium phosphate (NACP) in a stimulated oral biofilm environment. METHODS: The enamel blocks were immersed in demineralization solution for 72 h to imitate artificial initial carious lesion and then subjected to a Streptococcus mutans biofilm for 24 h. All the samples then underwent 4-h demineralization in brain heart infusion broth with sucrose (BHIS) and 20-h remineralization in artificial saliva (AS) for 7 days. The daily pH of BHIS after 4-h incubation, lactic acid production, colony-forming unit (CFU) count, and content of calcium (Ca) and phosphate (P) in biofilm were evaluated. Meanwhile, the remineralization effectiveness of enamel was analyzed by X-ray diffraction (XRD), surface microhardness testing, transverse microradiography (TMR) and scanning electron microscopy (SEM). RESULTS: The NACP adhesive released abundant Ca and P, achieved acid neutralization, reduced lactic acid production, and lowered CFU count (P < 0.05). Enamel treated with NACP adhesive demonstrated the best remineralization effectiveness with remineralization value of 52.29 ± 4.79% according to TMR. Better microhardness recovery of cross sections and ample mineral deposits were also observed in NACP group. CONCLUSIONS: The NACP adhesive exhibited good performance in remineralizing initial enamel lesion with cariogenic biofilm. SIGNIFICANCE: The NACP adhesive is promising to be applied for the protection of bonding interface, prevention of secondary caries, and longevity prolonging of the restoration.


Assuntos
Cárie Dentária , Nanopartículas , Antibacterianos , Biofilmes , Fosfatos de Cálcio , Cárie Dentária/tratamento farmacológico , Suscetibilidade à Cárie Dentária , Cimentos Dentários , Humanos , Metacrilatos , Remineralização Dentária
15.
Sensors (Basel) ; 21(22)2021 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-34833745

RESUMO

Tunneling magnetoresistive (TMR) sensors have broad application prospects because of their high sensitivity and small volume. However, the inherent hysteresis characteristics of TMR affect its applications in high accuracy scenarios. It is essential to build a model to describe the attributes of hysteresis of TMR accurately. Preisach model is one of the popular models to describe the behavior of inherent hysteresis for TMR, whereas it presents low accuracy in high-order hysteresis reversal curves. Furthermore, the traditional Preisach model has strict congruence constraints, and the amount of data seriously affects the accuracy. This paper proposes a hysteresis model from a probability perspective. This model has the same computational complexity as the classic Preisach model while presenting higher accuracy, especially in high-order hysteresis reversal curves. When measuring a small amount of data, the error of this method is significantly reduced compared with the classical Preisach model. Besides, the proposed model's congruence in this paper only needs equal vertical chords.

16.
Sensors (Basel) ; 21(12)2021 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-34208671

RESUMO

An alignment-free sensing module for the positioning system based on tunneling magnetoresistive (TMR) sensors with an absolute-incremental-integrated scale is demonstrated. The sensors of the proposed system for both lines consist of identical layer stacks; therefore, all sensors can be fabricated in identical processes from thin film deposition to device patterning on a single substrate. Consequently, the relative position of the sensors can be predefined at the lithography stage and the alignment error between sensors caused by the manual installation is completely eliminated. Different from the existing sensing scheme for incremental lines, we proposed to utilize the magnetic tunnel junctions with a perpendicular anisotropy reference layer and an in-plane anisotropy sensing layer. The sensors are placed parallel to the scale plane with magnetization of the sensing layer in the plane, which show the capability of polarity detection for the absolute line and reveal sinusoidal output signal for the incremental line. Furthermore, due to the large signal of TMR, the working distance can be further improved compared with conventional sensors. In addition, the cost of the positioning system is expected to be lowered, since all the sensors are fabricated in the same process without extra installation. Our design may pave a new avenue for the positioning system based on a magnetic detection scheme.

17.
Sensors (Basel) ; 21(6)2021 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-33802231

RESUMO

The evolution of technological and surgical techniques has made it possible to obtain an even more intuitive control of multiple joints using advanced prosthetic systems. Targeted Muscle Reinnervation (TMR) is considered to be an innovative and relevant surgical technique for improving the prosthetic control for people with different amputation levels of the limb. Indeed, TMR surgery makes it possible to obtain reinnervated areas that act as biological amplifiers of the motor control. On the technological side, a great deal of research has been conducted in order to evaluate various types of myoelectric prosthetic control strategies, whether direct control or pattern recognition-based control. In the literature, different control performance metrics, which have been evaluated on TMR subjects, have been introduced, but no accepted reference standard defines the better strategy for evaluating the prosthetic control. Indeed, the presence of several evaluation tests that are based on different metrics makes it difficult the definition of standard guidelines for comprehending the potentiality of the proposed control systems. Additionally, there is a lack of evidence about the comparison of different evaluation approaches or the presence of guidelines on the most suitable test to proceed for a TMR patients case study. Thus, this review aims at identifying these limitations by examining the several studies in the literature on TMR subjects, with different amputation levels, and proposing a standard method for evaluating the control performance metrics.


Assuntos
Membros Artificiais , Amputação Cirúrgica , Cotos de Amputação , Eletromiografia , Humanos , Extremidade Superior
18.
J Surg Oncol ; 122(8): 1693-1710, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32885434

RESUMO

BACKGROUND: Targeted muscle reinnervation (TMR) has been shown to decrease or prevent neuropathic pain, including phantom and residual limb pain, after extremity amputation. Currently, a paucity of data and lack of anatomical description exists regarding TMR in the setting of hemipelvectomy and/or hip disarticulations. We elaborate on the technique of TMR, illustrated through cadaveric and clinical correlates. METHODS: Cadaveric dissections of multiple transpelvic exposures were performed. The major mixed motor and sensory nerve branches were identified, dissected, and tagged. Amputated peripheral nerves were transferred to identified, labeled target motor nerves via direct end-to-end nerve coaptations per traditional TMR technique. A retrospective review was completed by our multi-institutional teams to include examples of clinical correlates for TMR performed in the setting of hemipelvectomies and hip disarticulations. RESULTS: A total of 12 TMR hemipelvectomy/hip disarticulation cases were performed over a 2 to 3-year period (2018-2020). Of these 12 cases, 9 were oncologic in nature, 2 were secondary to traumatic injury, and 1 was a failed limb salvage in the setting of chronic refractory osteomyelitis of the femoral shaft. CONCLUSIONS: This manuscript outlines the technical considerations for TMR in the setting of hemipelvectomy and hip disarticulation with supporting clinical case correlates.


Assuntos
Amputados/reabilitação , Desarticulação/métodos , Hemipelvectomia/métodos , Músculos/inervação , Músculos/cirurgia , Membro Fantasma/prevenção & controle , Procedimentos de Cirurgia Plástica/métodos , Feminino , Seguimentos , Humanos , Masculino , Prognóstico , Estudos Retrospectivos
19.
J Appl Microbiol ; 128(3): 675-687, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31721404

RESUMO

AIM: To compare the effects of steam explosion and Lactobacillus buchneri inoculation on fungal community in ensiled total mixed ration (TMR) during aerobic exposure. METHODS AND RESULTS: The TMRs were prepared using wheat straw with or without steam explosion, sweet potato residue, lucerne hay, maize meal and soybean meal, and ensiled with or without L. buchneri inoculation. Fungal communities were detected by high-throughput sequencing. All ensiled TMRs were well ensiled and steam explosion has a major effect on improving aerobic stability. The fungal species, such as Xeromyces bisporus and Cryptococcus victoriae, that dominated in the TMR decreased after ensiling, with a concomitant increase in Candida humilis, Pichia kudriavzevii, Aspergillus flavus and Phanerochaete chrysosporium. Most mould species decreased, with C. humilis and P. kudriavzevii dominating during aerobic exposure. CONCLUSION: Steam explosion could improve the aerobic stability in ensiled TMR by inhibition of C. humilis. SIGNIFICANCE AND IMPACT OF THE STUDY: High-throughput sequencing used in this study provides insight into the fungal community in ensiled TMR during aerobic exposure, which could contribute towards elucidating the mechanism by which aerobic deterioration develops.


Assuntos
Fungos/isolamento & purificação , Lactobacillus , Silagem/microbiologia , Triticum , Aerobiose , Micobioma , Poaceae , Glycine max , Vapor , Zea mays
20.
J Dairy Sci ; 103(10): 8721-8731, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32773315

RESUMO

The animal diet is a critical variable affecting the composition and functionality of dairy products. As "Grass-Fed" labeling becomes more prominent on the market, rapid and label-free methods for verification of feeding systems are required. This work proposes the use of Raman spectroscopy to study the effects of 3 different experimental cow feeding systems-perennial ryegrass pasture, perennial ryegrass with white clover pasture, and an indoor total mixed ration diet (TMR)-on the nutritional quality of sweet cream butter. The results demonstrate that Raman spectroscopy coupled with multivariate analysis is a promising approach to distinguish butter derived from pasture or conventional TMR feeding systems. A Pearson correlation analysis confirmed high positive correlations between the spectral bin at 1,657 cm-1, ascribed to the stretching vibrations of C=C bonds, and concentrations of α-linolenic acid and conjugated linolenic acid (CLA) in butter, and in general with the concentration of n-3 and n-3+CLA fatty acids and polyunsaturated fatty acids in the samples. The yellow color indicative of the presence of carotenoids in butter, which has previously been suggested as a biomarker of pasture or "Grass-Fed" feeding, was also positively correlated with the data obtained from the Raman spectra. Raman spectroscopy could also be used to accurately predict indicators of the nutritional quality of butter, such as the thrombogenic index, which showed a strong negative correlation with the spectral bin at 3,023 cm-1.


Assuntos
Ração Animal , Manteiga/análise , Herbivoria , Valor Nutritivo , Análise Espectral Raman , Ração Animal/análise , Animais , Bovinos , Ácidos Graxos/análise , Feminino , Lactação , Lolium , Leite/química , Projetos Piloto , Poaceae , Trifolium
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA