Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.043
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Circulation ; 149(10): 734-743, 2024 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-37874908

RESUMO

BACKGROUND: Atrial fibrillation (AF) is common in patients undergoing transcatheter aortic valve replacement (TAVR) and is associated with increased risk of bleeding and stroke. While left atrial appendage occlusion (LAAO) is approved as an alternative to anticoagulants for stroke prevention in patients with AF, placement of these devices in patients with severe aortic stenosis, or when performed at the same time as TAVR, has not been extensively studied. METHODS: WATCH-TAVR (WATCHMAN for Patients with AF Undergoing TAVR) was a multicenter, randomized trial evaluating the safety and effectiveness of concomitant TAVR and LAAO with WATCHMAN in AF patients. Patients were randomized 1:1 to TAVR + LAAO or TAVR + medical therapy. WATCHMAN patients received anticoagulation for 45 days followed by dual antiplatelet therapy until 6 months. Anticoagulation was per treating physician preference for patients randomized to TAVR + medical therapy. The primary noninferiority end point was all-cause mortality, stroke, and major bleeding at 2 years between the 2 strategies. RESULTS: The study enrolled 349 patients (177 TAVR + LAAO and 172 TAVR + medical therapy) between December 2017 and November 2020 at 34 US centers. The mean age of patients was 81 years, and the mean scores for CHA2DS2-VASc and HAS-BLED (Hypertension, Abnormal renal/liver function, Stroke, Bleeding history or predisposition, Labile INR, Elderly, Drugs/alcohol concomitantly) were 4.9 and 3.0, respectively. At baseline, 85.4% of patients were taking anticoagulants and 71.3% patients were on antiplatelet therapy. The cohorts were well-balanced for baseline characteristics. The incremental LAAO procedure time was 38 minutes, and the median contrast volume used for combined procedures was 119 mL versus 70 mL with TAVR alone. At the 24-month follow-up, 82.5% compared with 50.8% of patients were on any antiplatelet therapy, and 13.9% compared with 66.7% of patients were on any anticoagulation therapy in TAVR + LAAO compared with TAVR + medical therapy group, respectively. For the composite primary end point, TAVR + LAAO was noninferior to TAVR + medical therapy (22.7 versus 27.3 events per 100 patient-years for TAVR + LAAO and TAVR + medical therapy, respectively; hazard ratio, 0.86 [95% CI, 0.60-1.22]; Pnoninferiority<0.001). CONCLUSIONS: Concomitant WATCHMAN LAAO and TAVR is noninferior to TAVR with medical therapy in severe aortic stenosis patients with AF. The increased complexity and risks of the combined procedure should be considered when concomitant LAAO is viewed as an alternative to medical therapy for patients with AF undergoing TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03173534.


Assuntos
Estenose da Valva Aórtica , Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Apêndice Atrial/cirurgia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Hemorragia/induzido quimicamente , Anticoagulantes/efeitos adversos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
2.
Circulation ; 150(12): 952-965, 2024 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-38836358

RESUMO

BACKGROUND: Whether aortic valve stenosis (AS) can adversely affect systemic endothelial function independently of standard modifiable cardiovascular risk factors is unknown. METHODS: We therefore investigated endothelial and cardiac function in an experimental model of AS mice devoid of standard modifiable cardiovascular risk factors and human cohorts with AS scheduled for transcatheter aortic valve replacement. Endothelial function was determined by flow-mediated dilation using ultrasound. Extracellular hemoglobin (eHb) concentrations and nitric oxide (NO) consumption were determined in blood plasma of mice and humans by ELISA and chemiluminescence. This was complemented by measurements of aortic blood flow using 4-dimensional flow acquisition by magnetic resonance imaging and computational fluid dynamics simulations. The effects of plasma and red blood cell (RBC) suspensions on vascular function were determined in transfer experiments in a murine vasorelaxation bioassay system. RESULTS: In mice, the induction of AS caused systemic endothelial dysfunction. In the presence of normal systolic left ventricular function and mild hypertrophy, the increase in the transvalvular gradient was associated with elevated eryptosis, increased eHb, and increased plasma NO consumption; eHb sequestration by haptoglobin restored endothelial function. Because the aortic valve orifice area in patients with AS decreased, postvalvular mechanical stress in the central ascending aorta increased. This was associated with elevated eHb, circulating RBC-derived microvesicles, eryptotic cells, lower haptoglobin levels without clinically relevant anemia, and consecutive endothelial dysfunction. Transfer experiments demonstrated that reduction of eHb by treatment with haptoglobin or elimination of fluid dynamic stress by transcatheter aortic valve replacement restored endothelial function. In patients with AS and subclinical RBC fragmentation, the remaining circulating RBCs before and after transcatheter aortic valve replacement exhibited intact membrane function, deformability, and resistance to osmotic and hypoxic stress. CONCLUSIONS: AS increases postvalvular swirling blood flow in the central ascending aorta, triggering RBC fragmentation with the accumulation of hemoglobin in the plasma. This increases NO consumption in blood, thereby limiting vascular NO bioavailability. Thus, AS itself promotes systemic endothelial dysfunction independent of other established risk factors. Transcatheter aortic valve replacement is capable of limiting NO scavenging and rescuing endothelial function by realigning postvalvular blood flow to near physiological patterns. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT05603520 and NCT01805739.


Assuntos
Estenose da Valva Aórtica , Endotélio Vascular , Hemoglobinas , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/metabolismo , Animais , Humanos , Endotélio Vascular/metabolismo , Endotélio Vascular/fisiopatologia , Camundongos , Hemoglobinas/metabolismo , Masculino , Feminino , Camundongos Endogâmicos C57BL , Idoso , Substituição da Valva Aórtica Transcateter , Óxido Nítrico/metabolismo , Óxido Nítrico/sangue , Modelos Animais de Doenças , Idoso de 80 Anos ou mais , Vasodilatação
3.
Eur Heart J ; 45(11): 940-949, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38243821

RESUMO

BACKGROUND AND AIMS: Mitral valve surgery and, more recently, mitral transcatheter edge-to-edge repair (TEER) are the two treatments of severe mitral regurgitation in eligible patients. Clinical comparison of both therapies remains limited by the number of patients analysed. The objective of this study was to analyse the outcomes of mitral TEER vs. isolated mitral valve surgery at a nationwide level in France. METHODS: Based on the French administrative hospital discharge database, the study collected information for all consecutive patients treated for mitral regurgitation with isolated TEER or isolated mitral valve surgery between 2012 and 2022. Propensity score matching was used for the analysis of outcomes. RESULTS: A total of 57 030 patients were found in the database. After matching on baseline characteristics, 2160 patients were analysed in each arm. At 3-year follow-up, TEER was associated with significantly lower incidence of cardiovascular death (hazard ratio 0.685, 95% confidence interval 0.563-0.832; P = .0001), pacemaker implantation, and stroke. Non-cardiovascular death (hazard ratio 1.562, 95% confidence interval 1.238-1.971; P = .0002), recurrent pulmonary oedema, and cardiac arrest were more frequent after TEER. No significant differences between the two groups were observed regarding all-cause death (hazard ratio 0.967, 95% confidence interval 0.835-1.118; P = .65), endocarditis, major bleeding, atrial fibrillation, and myocardial infarction. CONCLUSIONS: Our results suggest that TEER for severe mitral regurgitation was associated with lower cardiovascular mortality than mitral surgery at long-term follow-up. Pacemaker implantation and stroke were less frequently observed after TEER.


Assuntos
Fibrilação Atrial , Endocardite , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Acidente Vascular Cerebral , Humanos , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Acidente Vascular Cerebral/epidemiologia , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Bases de Dados Factuais , Resultado do Tratamento
4.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Assuntos
Endocardite , Falha de Prótese , Infecções Relacionadas à Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/mortalidade , Endocardite/cirurgia , Endocardite/mortalidade , Remoção de Dispositivo , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
5.
Eur Heart J ; 45(13): 1116-1124, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38321820

RESUMO

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become a viable treatment option for patients with severe aortic valve stenosis across a broad range of surgical risk. The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize patients at lower surgical risk to TAVI or surgical aortic valve replacement (SAVR). The aim of the present study was to report clinical and bioprosthesis outcomes after 10 years. METHODS: The NOTION trial randomized 280 patients to TAVI with the self-expanding CoreValve (Medtronic Inc.) bioprosthesis (n = 145) or SAVR with a bioprosthesis (n = 135). The primary composite outcome was the risk of all-cause mortality, stroke, or myocardial infarction. Bioprosthetic valve dysfunction (BVD) was classified as structural valve deterioration (SVD), non-structural valve dysfunction (NSVD), clinical valve thrombosis, or endocarditis according to Valve Academic Research Consortium-3 criteria. Severe SVD was defined as (i) a transprosthetic gradient of 30 mmHg or more and an increase in transprosthetic gradient of 20 mmHg or more or (ii) severe new intraprosthetic regurgitation. Bioprosthetic valve failure (BVF) was defined as the composite rate of death from a valve-related cause or an unexplained death following the diagnosis of BVD, aortic valve re-intervention, or severe SVD. RESULTS: Baseline characteristics were similar between TAVI and SAVR: age 79.2 ± 4.9 years and 79.0 ± 4.7 years (P = .7), male 52.6% and 53.8% (P = .8), and Society of Thoracic Surgeons score < 4% of 83.4% and 80.0% (P = .5), respectively. After 10 years, the risk of the composite outcome all-cause mortality, stroke, or myocardial infarction was 65.5% after TAVI and 65.5% after SAVR [hazard ratio (HR) 1.0; 95% confidence interval (CI) 0.7-1.3; P = .9], with no difference for each individual outcome. Severe SVD had occurred in 1.5% and 10.0% (HR 0.2; 95% CI 0.04-0.7; P = .02) after TAVI and SAVR, respectively. The cumulative incidence for severe NSVD was 20.5% and 43.0% (P < .001) and for endocarditis 7.2% and 7.4% (P = 1.0) after TAVI and SAVR, respectively. No patients had clinical valve thrombosis. Bioprosthetic valve failure occurred in 9.7% of TAVI and 13.8% of SAVR patients (HR 0.7; 95% CI 0.4-1.5; P = .4). CONCLUSIONS: In patients with severe AS and lower surgical risk randomized to TAVI or SAVR, the risk of major clinical outcomes was not different 10 years after treatment. The risk of severe bioprosthesis SVD was lower after TAVR compared with SAVR, while the risk of BVF was similar.


Assuntos
Estenose da Valva Aórtica , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Infarto do Miocárdio , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Infarto do Miocárdio/etiologia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Endocardite/cirurgia , Trombose/etiologia
6.
Eur Heart J ; 45(21): 1877-1886, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38190428

RESUMO

BACKGROUND AND AIMS: Severe aortic stenosis (AS) is the guideline-based indication for aortic valve replacement (AVR), which has markedly increased with transcatheter approaches, suggesting possible increasing AS incidence. However, reported secular trends of AS incidence remain contradictory and lack quantitative Doppler echocardiographic ascertainment. METHODS: All adults residents in Olmsted County (MN, USA) diagnosed over 20 years (1997-2016) with incident severe AS (first diagnosis) based on quantitatively defined measures (aortic valve area ≤ 1 cm2, aortic valve area index ≤ 0.6 cm2/m2, mean gradient ≥ 40 mmHg, peak velocity ≥ 4 m/s, Doppler velocity index ≤ 0.25) were counted to define trends in incidence, presentation, treatment, and outcome. RESULTS: Incident severe AS was diagnosed in 1069 community residents. The incidence rate was 52.5 [49.4-55.8] per 100 000 patient-year, slightly higher in males vs. females and was almost unchanged after age and sex adjustment for the US population 53.8 [50.6-57.0] per 100 000 residents/year. Over 20 years, severe AS incidence remained stable (P = .2) but absolute burden of incident cases markedly increased (P = .0004) due to population growth. Incidence trend differed by sex, stable in men (incidence rate ratio 0.99, P = .7) but declining in women (incidence rate ratio 0.93, P = .02). Over the study, AS clinical characteristics remained remarkably stable and AVR performance grew and was more prompt (from 1.3 [0.1-3.3] years in 1997-2000 to 0.5 [0.2-2.1] years in 2013-16, P = .001) but undertreatment remained prominent (>40%). Early AVR was associated with survival benefit (adjusted hazard ratio 0.55 [0.42-0.71], P < .0001). Despite these improvements, overall mortality (3-month 8% and 3-year 36%), was swift, considerable and unabated (all P ≥ .4) throughout the study. CONCLUSIONS: Over 20 years, the population incidence of severe AS remained stable with increased absolute case burden related to population growth. Despite stable severe AS presentation, AVR performance grew notably, but while declining, undertreatment remained substantial and disease lethality did not yet decline. These population-based findings have important implications for improving AS management pathways.


Assuntos
Estenose da Valva Aórtica , Humanos , Estenose da Valva Aórtica/epidemiologia , Masculino , Feminino , Incidência , Idoso , Pessoa de Meia-Idade , Minnesota/epidemiologia , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/tendências , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Ecocardiografia Doppler , Implante de Prótese de Valva Cardíaca/tendências , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Índice de Gravidade de Doença , Resultado do Tratamento
7.
Eur Heart J ; 45(21): 1890-1900, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38270189

RESUMO

BACKGROUND AND AIMS: In transcatheter aortic valve replacement (TAVR) recipients, the optimal management of concomitant chronic obstructive coronary artery disease (CAD) remains unknown. Some advocate for pre-TAVR percutaneous coronary intervention, while others manage it expectantly. The aim of this study was to assess the impact of varying degrees and extent of untreated chronic obstructive CAD on TAVR and longer-term outcomes. METHODS: The authors conducted a retrospective cohort study of TAVR recipients from January 2015 to November 2021, separating patients into stable non-obstructive or varying degrees of obstructive CAD. The major outcomes of interest were procedural all-cause mortality and complications, major adverse cardiovascular events, and post-TAVR unplanned coronary revascularization. RESULTS: Of the 1911 patients meeting inclusion, 75%, 6%, 10%, and 9% had non-obstructive, intermediate-risk, high-risk, and extreme-risk CAD, respectively. Procedural complication rates overall were low (death 0.4%, shock 0.1%, extracorporeal membrane oxygenation 0.1%), with no difference across groups. At a median follow-up of 21 months, rates of acute coronary syndrome and unplanned coronary revascularization were 0.7% and 0.5%, respectively, in the non-obstructive population, rising in incidence with increasing severity of CAD (P < .001 for acute coronary syndrome/unplanned coronary revascularization). Multivariable analysis did not yield a significantly greater risk of all-cause mortality or major adverse cardiovascular events across groups. One-year acute coronary syndrome and unplanned coronary revascularization rates in time-to-event analyses were significantly greater in the non-obstructive (98%) vs. obstructive (94%) subsets (Plog-rank< .001). CONCLUSIONS: Transcatheter aortic valve replacement can be performed safely in patients with untreated chronic obstructive CAD, without portending higher procedural complication rates and with relatively low rates of unplanned coronary revascularization and acute coronary syndrome at 1 year.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/mortalidade , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Idoso , Intervenção Coronária Percutânea , Resultado do Tratamento , Fatores de Risco
8.
Eur Heart J ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38953786

RESUMO

BACKGROUND AND AIMS: Physical activity has proven effective in preventing atherosclerotic cardiovascular disease, but its role in preventing degenerative valvular heart disease (VHD) remains uncertain. This study aimed to explore the dose-response association between moderate to vigorous physical activity (MVPA) volume and the risk of degenerative VHD among middle-aged adults. METHODS: A full week of accelerometer-derived MVPA data from 87 248 UK Biobank participants (median age 63.3, female: 56.9%) between 2013 and 2015 were used for primary analysis. Questionnaire-derived MVPA data from 361 681 UK Biobank participants (median age 57.7, female: 52.7%) between 2006 and 2010 were used for secondary analysis. The primary outcome was the diagnosis of incident degenerative VHD, including aortic valve stenosis (AS), aortic valve regurgitation (AR), and mitral valve regurgitation (MR). The secondary outcome was VHD-related intervention or mortality. RESULTS: In the accelerometer-derived MVPA cohort, 555 incident AS, 201 incident AR, and 655 incident MR occurred during a median follow-up of 8.11 years. Increased MVPA volume showed a steady decline in AS risk and subsequent AS-related intervention or mortality risk, levelling off beyond approximately 300 min/week. In contrast, its association with AR or MR incidence was less apparent. The adjusted rates of AS incidence (95% confidence interval) across MVPA quartiles (Q1-Q4) were 11.60 (10.20, 13.20), 7.82 (6.63, 9.23), 5.74 (4.67, 7.08), and 5.91 (4.73, 7.39) per 10 000 person-years. The corresponding adjusted rates of AS-related intervention or mortality were 4.37 (3.52, 5.43), 2.81 (2.13, 3.71), 1.93 (1.36, 2.75), and 2.14 (1.50, 3.06) per 10 000 person-years, respectively. Aortic valve stenosis risk reduction was also observed with questionnaire-based MVPA data [adjusted absolute difference Q4 vs. Q1: AS incidence, -1.41 (-.67, -2.14) per 10 000 person-years; AS-related intervention or mortality, -.38 (-.04, -.88) per 10 000 person-years]. The beneficial association remained consistent in high-risk populations for AS, including patients with hypertension, obesity, dyslipidaemia, and chronic kidney disease. CONCLUSIONS: Higher MVPA volume was associated with a lower risk of developing AS and subsequent AS-related intervention or mortality. Future research needs to validate these findings in diverse populations with longer durations and repeated periods of activity monitoring.

9.
Eur Heart J ; 45(3): 198-210, 2024 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-37874971

RESUMO

BACKGROUND AND AIMS: Transcatheter pulmonary valve implantation (TPVI) is indicated to treat right-ventricular outflow tract (RVOT) dysfunction related to congenital heart disease (CHD). Outcomes of TPVI with the SAPIEN 3 valve that are insufficiently documented were investigated in the EUROPULMS3 registry of SAPIEN 3-TPVI. METHODS: Patient-related, procedural, and follow-up outcome data were retrospectively assessed in this observational cohort from 35 centres in 15 countries. RESULTS: Data for 840 consecutive patients treated in 2014-2021 at a median age of 29.2 (19.0-41.6) years were obtained. The most common diagnosis was conotruncal defect (70.5%), with a native or patched RVOT in 50.7% of all patients. Valve sizes were 20, 23, 26, and 29 mm in 0.4%, 25.5%, 32.1%, and 42.0% of patients, respectively. Valve implantation was successful in 98.5% [95% confidence interval (CI), 97.4%-99.2%] of patients. Median follow-up was 20.3 (7.1-38.4) months. Eight patients experienced infective endocarditis; 11 required pulmonary valve replacement, with a lower incidence for larger valves (P = .009), and four experienced pulmonary valve thrombosis, including one who died and three who recovered with anticoagulation. Cumulative incidences (95%CI) 1, 3, and 6 years after TPVI were as follows: infective endocarditis, 0.5% (0.0%-1.0%), 0.9% (0.2%-1.6%), and 3.8% (0.0%-8.4%); pulmonary valve replacement, 0.4% (0.0%-0.8%), 1.3% (0.2%-2.4%), and 8.0% (1.2%-14.8%); and pulmonary valve thrombosis, 0.4% (0.0%-0.9%), 0.7% (0.0%-1.3%), and 0.7% (0.0%-1.3%), respectively. CONCLUSIONS: Outcomes of SAPIEN 3 TPVI were favourable in patients with CHD, half of whom had native or patched RVOTs.


Assuntos
Endocardite Bacteriana , Endocardite , Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Trombose , Adulto , Humanos , Cateterismo Cardíaco/efeitos adversos , Endocardite/epidemiologia , Endocardite Bacteriana/complicações , Cardiopatias Congênitas/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Desenho de Prótese , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/epidemiologia , Insuficiência da Valva Pulmonar/cirurgia , Sistema de Registros , Estudos Retrospectivos , Trombose/etiologia , Resultado do Tratamento
10.
Eur Heart J ; 45(37): 3804-3814, 2024 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-38747246

RESUMO

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become the first choice to treat older patients with severe symptomatic aortic stenosis (AS). This study aimed to compare TAVI with surgery in low-risk patients ≤75 years of age, including both tricuspid and bicuspid AS. METHODS: The Nordic Aortic Valve Intervention (NOTION)-2 trial enrolled and 1:1 randomized low-risk patients aged ≤75 years with severe symptomatic AS to TAVI or surgery. The primary endpoint was a composite of all-cause mortality, stroke, or rehospitalization (related to the procedure, valve, or heart failure) at 12 months. RESULTS: A total of 370 patients were enrolled with a mean age of 71.1 years and a median Society of Thoracic Surgeons risk score of 1.1%. A total of 100 patients had bicuspid AS. The 1-year incidence of the primary endpoint was 10.2% in the TAVI group and 7.1% in the surgery group [absolute risk difference 3.1%; 95% confidence interval (CI), -2.7% to 8.8%; hazard ratio (HR) 1.4; 95% CI, 0.7-2.9; P = .3]. Patients with TAVI, when compared to surgery, had lower risk of major bleeding and new-onset atrial fibrillation and higher risk of non-disabling stroke, permanent pacemaker implantation, and moderate or greater paravalvular regurgitation. The risk of the primary composite endpoint was 8.7% and 8.3% in patients with tricuspid AS (HR 1.0; 95% CI, 0.5-2.3) and 14.3% and 3.9% in patients with bicuspid AS (HR 3.8; 95% CI, 0.8-18.5) treated with TAVI or surgery, respectively (P for interaction = .1). CONCLUSIONS: Among low-risk patients aged ≤75 years with severe symptomatic AS, the rate of the composite of death, stroke, or rehospitalization at 1 year was similar between TAVI and surgery. Transcatheter aortic valve implantation outcomes in young bicuspid AS patients warrant caution and should be further investigated. (NOTION-2, ClinicalTrials.gov, NCT02825134). TRIAL REGISTRATION NUMBER: ClinicalTrials.gov NCT02825134.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Masculino , Feminino , Idoso , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/complicações , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/complicações , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Readmissão do Paciente/estatística & dados numéricos , Valva Tricúspide/cirurgia
11.
Circulation ; 148(16): 1220-1230, 2023 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-37634187

RESUMO

BACKGROUND: Computed tomography (CT) is recommended for guiding transcatheter aortic valve replacement (TAVR). However, a sizable proportion of TAVR candidates have chronic kidney disease, in whom the use of iodinated contrast media is a limitation. Cardiac magnetic resonance imaging (CMR) is a promising alternative, but randomized data comparing the effectiveness of CMR-guided versus CT-guided TAVR are lacking. METHODS: An investigator-initiated, prospective, randomized, open-label, noninferiority trial was conducted at 2 Austrian heart centers. Patients evaluated for TAVR according to the inclusion criteria (severe symptomatic aortic stenosis) and exclusion criteria (contraindication to CMR, CT, or TAVR, a life expectancy <1 year, or chronic kidney disease level 4 or 5) were randomized (1:1) to undergo CMR or CT guiding. The primary outcome was defined according to the Valve Academic Research Consortium-2 definition of implantation success at discharge, including absence of procedural mortality, correct positioning of a single prosthetic valve, and proper prosthetic valve performance. Noninferiority was assessed using a hybrid modified intention-to-treat/per-protocol approach on the basis of an absolute risk difference margin of 9%. RESULTS: Between September 11, 2017, and December 16, 2022, 380 candidates for TAVR were randomized to CMR-guided (191 patients) or CT-guided (189 patients) TAVR planning. Of these, 138 patients (72.3%) in the CMR-guided group and 129 patients (68.3%) in the CT-guided group eventually underwent TAVR (modified intention-to-treat cohort). Of these 267, 19 patients had protocol deviations, resulting in a per-protocol cohort of 248 patients (121 CMR-guided, 127 CT-guided). In the modified intention-to-treat cohort, implantation success was achieved in 129 patients (93.5%) in the CMR group and in 117 patients (90.7%) in the CT group (between-group difference, 2.8% [90% CI, -2.7% to 8.2%]; P<0.01 for noninferiority). In the per-protocol cohort (n=248), the between-group difference was 2.0% (90% CI, -3.8% to 7.8%; P<0.01 for noninferiority). CONCLUSIONS: CMR-guided TAVR was noninferior to CT-guided TAVR in terms of device implantation success. CMR can therefore be considered as an alternative for TAVR planning. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03831087.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética , Insuficiência Renal Crônica/cirurgia , Fatores de Risco
12.
Circulation ; 147(21): 1594-1605, 2023 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-37154049

RESUMO

BACKGROUND: In patients with severe symptomatic aortic stenosis at low surgical risk, transfemoral transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 valve has been shown to reduce the composite of death, stroke, or rehospitalization at 2-year follow-up compared with surgical aortic valve replacement (SAVR). Whether TAVR is cost-effective compared with SAVR for low-risk patients remains uncertain. METHODS: Between 2016 and 2017, 1000 low-risk patients with aortic stenosis were randomly assigned to TAVR with the SAPIEN 3 valve or SAVR in the PARTNER 3 trial (Placement of Aortic Transcatheter Valves). Of these patients, 929 underwent valve replacement, were enrolled in the United States, and were included in the economic substudy. Procedural costs were estimated using measured resource use. Other costs were determined by linkage with Medicare claims or by regression models when linkage was not feasible. Health utilities were estimated using the EuroQOL 5-item questionnaire. With the use of a Markov model informed by in-trial data, lifetime cost-effectiveness from the perspective of the US health care system was estimated in terms of cost per quality-adjusted life-year gained. RESULTS: Although procedural costs were nearly $19 000 higher with TAVR, total index hospitalization costs were only $591 more with TAVR compared with SAVR. Follow-up costs were lower with TAVR such that TAVR led to 2-year cost savings of $2030/patient compared with SAVR (95% CI, -$6222 to $1816) and a gain of 0.05 quality-adjusted life-years (95% CI, -0.003 to 0.102). In our base-case analysis, TAVR was projected to be an economically dominant strategy with a 95% probability that the incremental cost-effectiveness ratio for TAVR would be <$50 000/quality-adjusted life-year gained (consistent with high economic value from a US health care perspective). These findings were sensitive to differences in long-term survival, however, such that a modest long-term survival advantage with SAVR would render SAVR cost-effective (although not cost saving) compared with TAVR. CONCLUSIONS: For patients with severe aortic stenosis and low surgical risk similar to those enrolled in the PARTNER 3 trial, transfemoral TAVR with the SAPIEN 3 valve is cost saving compared with SAVR at 2 years and is projected to be economically attractive in the long run as long as there are no substantial differences in late death between the 2 strategies. Long-term follow-up will be critical to ultimately determine the preferred treatment strategy for low-risk patients from both a clinical and economic perspective.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Estados Unidos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Medicare , Substituição da Valva Aórtica Transcateter/métodos , Fatores de Risco
13.
Stroke ; 2024 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-39371005

RESUMO

Cerebrovascular events (CVEs) are a dreaded complication of transcatheter aortic valve replacement (TAVR). They are associated with significant mortality, morbidity, and reduced quality of life and impose a significant burden to health care systems. Although the rates of clinical stroke have reduced since the advent of TAVR, it remains an important complication, particularly as TAVR is increasingly utilized. CVE may occur at the time of the TAVR, as a direct consequence of the procedure, or may occur later, related to thrombosis of the prosthetic valve, atrial fibrillation, and other comorbidities. Imaging of the brain has revealed a high prevalence of subclinical cerebral infarcts (68%-98%) associated with the TAVR procedure. Although their clinical significance has not been fully established, clinically evident CVE ranges between 3% and 5% in patients considered at high operative risk to between 1% and 3% in low operative risk patients. Periprocedural CVEs are largely the result of embolization of the thrombus and tissue derived from the valve, vasculature, or myocardium. Cerebral embolic protection devices have been studied in multiple trials, with some evidence supporting a reduction in new cerebral lesion volume, number, and potentially disabling strokes. However, thus far, there is no robust evidence that they reduce the overall stroke rate. The number and severity of comorbidities, in particular, new-onset atrial fibrillation, are associated with CVEs. Valve thrombosis diagnosed using computed tomography as areas of hypoattenuated leaflet thickening has been identified in 10% to 15% of patients. This is a dynamic process associated with an increase in CVEs, but that resolves with anticoagulation or sometimes without it. Routine use of anticoagulation compared with a single antiplatelet agent is associated with an increased risk of bleeding, without any additional alleviation in risk of thromboembolism. Future studies to improve risk stratification could facilitate the tailoring of preventive therapies to patients at high risk of CVE, who stand to gain the most benefit.

14.
Ann Surg Oncol ; 31(8): 5449-5456, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38526833

RESUMO

BACKGROUND: In-hospital mortality and complication rates after partial and radical nephrectomy in patients with history of heart-valve replacement are unknown. PATIENTS AND METHODS: Relying on the National Inpatient Sample (2000-2019), kidney cancer patients undergoing partial or radical nephrectomy were stratified according to presence or absence of heart-valve replacement. Multivariable logistic and Poisson regression models addressed adverse hospital outcomes. RESULTS: Overall, 39,673 patients underwent partial nephrectomy versus 94,890 radical nephrectomy. Of those, 248 (0.6%) and 676 (0.7%) had a history of heart-valve replacement. Heart-valve replacement patients were older (median partial nephrectomy 69 versus 60 years; radical nephrectomy 71 versus 63 years), and more frequently exhibited Charlson comorbidity index ≥ 3 (partial nephrectomy 22 versus 12%; radical nephrectomy 32 versus 23%). In partial nephrectomy patients, history of heart-valve replacement increased the risk of cardiac complications [odds ratio (OR) 4.33; p < 0.001), blood transfusions (OR 2.00; p < 0.001), intraoperative complications (OR 1.53; p = 0.03), and longer hospital stay [rate ratio (RR) 1.25; p < 0.001], but not in-hospital mortality (p = 0.5). In radical nephrectomy patients, history of heart-valve replacement increased risk of postoperative bleeding (OR 4.13; p < 0.001), cardiac complications (OR 2.72; p < 0.001), intraoperative complications (OR 1.53; p < 0.001), blood transfusions (OR 1.27; p = 0.02), and longer hospital stay (RR 1.12; p < 0.001), but not in-hospital mortality (p = 0.5). CONCLUSIONS: History of heart-valve replacement independently predicted four of twelve adverse outcomes in partial nephrectomy and five of twelve adverse outcomes in radical nephrectomy patients including intraoperative and cardiac complications, blood transfusions, and longer hospital stay. Conversely, no statistically significant differences were observed in in-hospital mortality.


Assuntos
Mortalidade Hospitalar , Neoplasias Renais , Nefrectomia , Complicações Pós-Operatórias , Humanos , Nefrectomia/mortalidade , Nefrectomia/efeitos adversos , Nefrectomia/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/etiologia , Neoplasias Renais/cirurgia , Neoplasias Renais/mortalidade , Neoplasias Renais/patologia , Seguimentos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Taxa de Sobrevida , Prognóstico , Tempo de Internação/estatística & dados numéricos , Complicações Intraoperatórias/mortalidade , Fatores de Risco
15.
J Cardiovasc Electrophysiol ; 35(3): 488-497, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38254339

RESUMO

Transcatheter aortic valve replacement (TAVR) often leads to conduction abnormalities, necessitating pacemaker implantation. This review of 38 meta-analyses identified preexisting right bundle branch block (RBBB), LAHB, and new-onset left bundle branch block as key risk factors, with a higher PPM risk in male and older patients. Procedural factors like transfemoral access and self-expandable valves also increase this risk. Prevention focuses on tailoring TAVR to individual electrophysiological and anatomical profiles. However, there's a lack of consensus in managing these conduction disturbances post-TAVR, highlighting the need for further research and standardized treatment strategies.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Marca-Passo Artificial/efeitos adversos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/prevenção & controle , Valva Aórtica/cirurgia
16.
Heart Fail Rev ; 29(1): 219-226, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37851119

RESUMO

Tricuspid regurgitation (TR) is the most common valvular pathology after heart transplantation (HTx) and endomyocardial biopsy (EMB) remains responsible for the majority of cases due to the high probability of structural valve damage. The aim of the present review was to describe the results of surgical management of severe tricuspid regurgitation through tricuspid valve replacement (TVR) after a previous HTx. A systematic review was conducted by searching Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane databases until June 2023 for publications reporting patients undergoing TVR surgery after a previous HTx. If no right heart valve surgery was undertaken, or a heterotopic heart transplant was performed, or if the concomitant procedure was performed during the transplant itself, the paper was excluded. Twenty articles met our inclusion criteria out of 1532 potentially eligible studies, with a total of 300 patients. Mean age was 55.1 ± 9.6 years, and 85.1% were male. The mean number of EMB per patient was 31.1 ± 5.5 with a mean time between HTx and TVR of 7.64 ± 3.31 years. Bioprostheses were used in 83.3% of cases and 75.0% of patients with a bioprosthesis were reported as alive at last follow-up. Tricuspid valve repair is a valuable option, but these patients will be susceptible to recurrent TR after EMB. TVR with a bioprosthesis may provide the optimal solution for this subset of patients, as EMB is not feasible with a mechanical valve.


Assuntos
Transplante de Coração , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/complicações , Valva Tricúspide/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Próteses Valvulares Cardíacas/efeitos adversos , Transplante de Coração/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos
17.
Cardiovasc Diabetol ; 23(1): 73, 2024 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-38365751

RESUMO

BACKGROUND: Stress hyperglycemia ratio (SHR) has recently been recognized as a novel biomarker that accurately reflects acute hyperglycemia status and is associated with poor prognosis of heart failure. We evaluated the relationship between SHR and clinical outcomes in patients with severe aortic stenosis receiving transcatheter aortic valve replacement (TAVR). METHODS: There were 582 patients with severe native aortic stenosis who underwent TAVR consecutively enrolled in the study. The formula used to determine SHR was as follows: admission blood glucose (mmol/L)/(1.59×HbA1c[%]-2.59). The primary endpoint was defined as all-cause mortality, while secondary endpoints included a composite of cardiovascular mortality or readmission for heart failure, and major adverse cardiovascular events (MACE) including cardiovascular mortality, non-fatal myocardial infarction, and non-fatal stroke. Multivariable Cox regression and restricted cubic spline analysis were employed to assess the relationship between SHR and endpoints, with hazard ratios (HRs) and 95% confidence intervals (CIs). RESULTS: During a median follow-up of 3.9 years, a total of 130 cases (22.3%) of all-cause mortality were recorded. Results from the restricted cubic spline analysis indicated a linear association between SHR and all endpoints (p for non-linearity > 0.05), even after adjustment for other confounding factors. Per 0.1 unit increase in SHR was associated with a 12% (adjusted HR: 1.12, 95% CI: 1.04-1.21) higher incidence of the primary endpoint, a 12% (adjusted HR: 1.12, 95% CI: 1.02-1.22) higher incidence of cardiovascular mortality or readmission for heart failure, and a 12% (adjusted HR: 1.12, 95% CI: 1.01-1.23) higher incidence of MACE. Subgroup analysis revealed that SHR had a significant interaction with diabetes mellitus with regard to the risk of all-cause mortality (p for interaction: 0.042). Kaplan-Meier survival analysis showed that there were significant differences in the incidence of all endpoints between the two groups with 0.944 as the optimal binary cutoff point of SHR (all log-rank test: p < 0.05). CONCLUSIONS: Our study indicates linear relationships of SHR with the risk of all-cause mortality, cardiovascular mortality or readmission for heart failure, and MACE in patients with severe aortic stenosis receiving TAVR after a median follow-up of 3.9 years. Patients with an SHR exceeding 0.944 had a poorer prognosis compared to those with lower SHR values.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Hiperglicemia , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Prognóstico , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Hiperglicemia/diagnóstico , Fatores de Risco
18.
Cardiovasc Diabetol ; 23(1): 260, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39026315

RESUMO

BACKGROUND: Type I and type II diabetes mellitus (DM) patients have a higher prevalence of cardiovascular diseases, as well as a higher mortality risk of cardiovascular diseases and interventions. This study provides an update on the impact of DM on clinical outcomes, including mortality, complications and reinterventions, using data on percutaneous and surgical cardiac interventions in the Netherlands. METHODS: This is a retrospective, nearby nationwide study using real-world observational data registered by the Netherlands Heart Registration (NHR) between 2015 and 2020. Patients treated for combined or isolated coronary artery disease (CAD) and aortic valve disease (AVD) were studied. Bivariate analyses and multivariate logistic regression models were used to evaluate the association between DM and clinical outcomes both unadjusted and adjusted for baseline characteristics. RESULTS: 241,360 patients underwent the following interventions; percutaneous coronary intervention(N = 177,556), coronary artery bypass grafting(N = 39,069), transcatheter aortic valve implantation(N = 11,819), aortic valve replacement(N = 8,028) and combined CABG and AVR(N = 4,888). The incidence of DM type I and II was 21.1%, 26.7%, 17.8%, 27.6% and 27% respectively. For all procedures, there are statistically significant differences between patients living with and without diabetes, adjusted for baseline characteristics, at the expense of patients with diabetes for 30-days mortality after PCI (OR = 1.68; p <.001); 120-days mortality after CABG (OR = 1.35; p <.001), AVR (OR = 1.5; p <.03) and CABG + AVR (OR = 1.42; p =.02); and 1-year mortality after CABG (OR = 1.43; p <.001), TAVI (OR = 1.21; p =.01) and PCI (OR = 1.68; p <.001). CONCLUSION: Patients with DM remain to have unfavourable outcomes compared to nondiabetic patients which calls for a critical reappraisal of existing care pathways aimed at diabetic patients within the cardiovascular field.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana , Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Intervenção Coronária Percutânea , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Estudos Retrospectivos , Resultado do Tratamento , Intervenção Coronária Percutânea/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Fatores de Tempo , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/cirurgia , Pessoa de Meia-Idade , Medição de Risco , Idoso de 80 Anos ou mais , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Países Baixos/epidemiologia , Diabetes Mellitus Tipo 2/mortalidade , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/terapia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Diabetes Mellitus Tipo 1/mortalidade , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/terapia , Incidência , Valvopatia Aórtica/cirurgia , Valvopatia Aórtica/mortalidade , Complicações Pós-Operatórias/mortalidade , Hospitais com Alto Volume de Atendimentos
19.
Cardiovasc Diabetol ; 23(1): 312, 2024 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-39182080

RESUMO

BACKGROUND: The triglyceride glucose (TyG) index, as a reliable marker of insulin resistance, is associated with the incidence and poor prognosis of various cardiovascular diseases. However, the relationship between the TyG index and clinical outcomes in patients with severe aortic stenosis (AS) who underwent transcatheter aortic valve replacement (TAVR) remains unclear. METHODS: This study consecutively enrolled 1569 patients with AS underwent TAVR at West China Hospital of Sichuan University between April 2014 and August 2023. The outcomes of interest included all-cause mortality, cardiovascular mortality, and major adverse cardiovascular events (MACE). Multivariate adjusted Cox regression and restricted cubic splines (RCS) regression analyses were used to assess the associations between the TyG index and the clinical outcomes. The incremental prognostic value of the TyG index was further assessed by the time-dependent Harrell's C-index, integrated discrimination improvement (IDI) and the net reclassification improvement (NRI). RESULTS: During a median follow-up of 1.09 years, there were 146, 70, and 196 patients experienced all-cause death, cardiovascular death, and MACE, respectively. After fully adjusting for confounders, a per-unit increase of TyG index was associated with a 441% (adjusted HR: 5.41, 95% CI: 4.01-7.32), 385% (adjusted HR: 4.85, 95% CI: 3.16-7.43), and 347% (adjusted HR: 4.47, 95% CI: 3.42-5.85) higher risk of all-cause mortality, cardiovascular mortality and MACE, respectively. The RCS regression analyses revealed a linear association between TyG index and endpoints (all P for non-linearity > 0.05) with 8.40 as the optimal binary cutoff point. Furthermore, adding TyG index to the basic risk model provided a significant incremental value in predicting poor prognosis (Time-dependent Harrell's C-index increased for all the endpoints; All-cause mortality, IDI: 0.11, P < 0.001; NRI: 0.32, P < 0.001; Cardiovascular mortality, IDI: 0.043, P < 0.001; NRI: 0.37, P < 0.001; MACE, IDI: 0.092, P < 0.001; NRI: 0.32, P < 0.001). CONCLUSIONS: In patients with severe AS receiving TAVR, there was a positive linear relationship between TyG index and poor prognosis, with 8.4 as the optimal bivariate cutoff value. Our findings suggest TyG index holds potential value for risk stratification and guiding therapeutic decisions in patients after TAVR.


Assuntos
Estenose da Valva Aórtica , Biomarcadores , Glicemia , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Triglicerídeos , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Idoso , Medição de Risco , Fatores de Risco , Idoso de 80 Anos ou mais , Fatores de Tempo , Resultado do Tratamento , China/epidemiologia , Biomarcadores/sangue , Glicemia/metabolismo , Triglicerídeos/sangue , Causas de Morte , Resistência à Insulina
20.
Rev Cardiovasc Med ; 25(5): 182, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-39076485

RESUMO

Functional tricuspid regurgitation (FTR) is a common type of tricuspid regurgitation (TR), particularly in cases of left heart valve disease. Historically, cardiac surgeons have not placed much emphasis on FTR and instead focused primarily on managing left heart valve disease. However, as research has progressed, it has become evident that severe TR significantly impacts the prognosis of heart valve surgery. Furthermore, significant improvements in postoperative cardiac function and quality of life have been observed when addressing the tricuspid valve alongside left heart disease management. This article aims to review current approaches for and timing of the surgical management of FTR while also analyzing the limitations of existing tricuspid surgical strategies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA