Ann Hematol ; 103(8): 3219-3227, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38935318

RESUMO

INTRODUCTION: There are significant differences in the activated partial thromboplastin time (APTT) critical values reported in different studies, most of which does not make recommendations for any specific clear detection systems. The International Council for Standardization in Hematology (ICSH) recommends that APTT critical values be established based on the reagent type, coagulation factor sensitivity and heparin response. The objective of this study was to establish APTT critical values by using different reagents and based on single coagulation factor deficiencies. METHODS: The APTT values were determined in commercial endogenous coagulation factor-deficient plasma at concentrations of 1 IU/dL, 2 IU/dL, 5 IU/dL, 10 IU/dL, 20 IU/dL, and 30 IU/dL by using four assay systems. The retrospective collection of data from patients who lacked factor VIII (FVIII), FIX, or FXI alone was performed. Receiver operating characteristic (ROC) curves were constructed to assess the diagnostic accuracy of APTT for identifying patients with an endogenous coagulation factor activity < 5 IU/dL. RESULTS: The APTT values in the plasma samples with the same concentrations of endogenous coagulation factors were significantly different among the four assay systems (P < 0.001). The suggested critical values of APTT were 40.0 s for Sysmex CS5100 (Actin FSL), 58.0 s for Sysmex CS5100 (Actin), 51.8 s for STA-R Evolution (STA-PTTA), and 64.8 s for ACL TOP 700 (HemosIL SynthasIL). On the basis of the ROC curve, the optimal threshold values for APTT (STA-PTTA) were 55.8 s in patients with a simple deficiency of FVIII (sensitivity = 100%, specificity = 85.7%, area under the ROC curve (AUC) = 0.982), 54.3 s in patients with a simple deficiency of FIX (sensitivity = 100%, specificity = 92.9%, AUC = 0.986), and 71.7 s in patients with a simple deficiency of FXI (sensitivity = 100%, specificity = 94.1%, AUC = 0.992), which were closer (difference of 0.6-2.5 s) to the cutoff points for commercial plasma at equal factor levels. CONCLUSIONS: APTT critical values need to be established for different reagents based on the presence of a single coagulation factor deficiency.


Assuntos
Fatores de Coagulação Sanguínea , Humanos , Tempo de Tromboplastina Parcial , Estudos Retrospectivos , Fatores de Coagulação Sanguínea/análise , Feminino , Masculino , Transtornos de Proteínas de Coagulação/sangue , Transtornos de Proteínas de Coagulação/diagnóstico , Curva ROC , Testes de Coagulação Sanguínea/métodos , Testes de Coagulação Sanguínea/normas , Indicadores e Reagentes
2.
Haemophilia ; 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39118287

RESUMO

OBJECTIVE: To analyse the demographic, clinical and laboratory data of Beninese patients with haemophilia. METHOD: A prospective survey was conducted in three different hospitals of Benin from April 2021 to March 2022, to analyse clinical and biological features of patients with haemophilia previously diagnosed or identified based on personal/family history. RESULTS: A total of 101 patients were studied, 97 with haemophilia A and 4 with haemophilia B, including 26 new cases identified after family investigation. Their median age was 11 years, and the most frequent initial manifestations were cutaneous-mucosal haemorrhages (29.70%) and post-circumcision haemorrhages (25.74%). Previous joint bleedings were present in 77% of them, with an arthropathy in 65 cases, which particularly affected the knees (75%), elbows (41%) and ankles (29%). Factor VIII (FVIII) levels combined with activated partial thromboplastin time (APTT) values did not always enable, as would be expected, the distinction between severe and moderate haemophilia, since they were >1 IU/dl in 31 of 74 patients with APTT > 80 s, and between 1 and 2 IU/dl in 26 other cases with previous joint haemorrhages, including 18 with chronic arthropathy. Therefore, for these patients, severe haemophilia could not be excluded, and this uncertainty probably reflects technical difficulties affecting the pre-analytical and analytical stages of the APTT and FVIII/IX assays. CONCLUSION: Our study proved that haemophilia is a significant reality in Benin, but also remains under-diagnosed in some districts of the country. In addition, more reliable biological tests are needed in the future to better define the severity of the disease and improve treatment of patients.

3.
Haemophilia ; 30(1): 214-223, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37902390

RESUMO

INTRODUCTION: Structural and chemical modifications of factor VIII (FVIII) products may influence their behaviour in FVIII activity assays. Hence, it is important to assess the performance of FVIII products in these assays. Efanesoctocog alfa is a new class of FVIII replacement therapy designed to provide both high sustained factor activity levels and prolonged plasma half-life. AIM: Evaluate the accuracy of measuring efanesoctocog alfa FVIII activity in one-stage clotting assays (OSAs) and chromogenic substrate assays (CSAs). METHODS: Human plasma with no detectable FVIII activity was spiked with efanesoctocog alfa or a full-length recombinant FVIII product comparator, octocog alfa, at nominal concentrations of 0.80 IU/mL, 0.20 IU/mL, or 0.05 IU/mL, based on labelled potency. Clinical haemostasis laboratories (N = 35) tested blinded samples using in-house assays. Data from 51 OSAs (14 activated partial thromboplastin time [aPTT] reagents) and 42 CSAs (eight kits) were analyzed. RESULTS: Efanesoctocog alfa activity was reliably (±25% of nominal activity) measured across all concentrations using OSAs with Actin FSL and multiple other aPTT reagents. Under- and overestimation of FVIII activity occurred with some reagents. No specific trend was observed for any class of aPTT activators. A two- to three-fold overestimation was consistently observed using CSAs and the OSA with Actin FS as the aPTT reagent across evaluated concentrations. CONCLUSION: Under- or overestimation occurred with some specific OSAs and most CSAs, which has been previously observed with other modified FVIII replacement products. Efanesoctocog alfa FVIII activity was measured with acceptable accuracy and reliability using several OSA methods and commercial plasma standards.


Assuntos
Hemofilia A , Hemostáticos , Apneia Obstrutiva do Sono , Humanos , Actinas , Testes de Coagulação Sanguínea/métodos , Compostos Cromogênicos/uso terapêutico , Fator VIII/uso terapêutico , Hemofilia A/tratamento farmacológico , Hemostasia , Hemostáticos/uso terapêutico , Indicadores e Reagentes , Laboratórios , Reprodutibilidade dos Testes , Apneia Obstrutiva do Sono/tratamento farmacológico
4.
Nanotechnology ; 35(17)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38262054

RESUMO

Heparins are a family of sulfated linear negatively charged polysaccharides that have been widely used for their anticoagulant, antithrombotic, antitumor, anti-inflammatory, and antiviral properties. Additionally, it has been used for acute cerebral infarction relief as well as other pharmacological actions. However, heparin's self-aggregated macrocomplex may reduce blood circulation time and induce life-threatening thrombocytopenia (HIT) complicating the use of heparins. Nonetheless, the conjugation of heparin to immuno-stealth biomolecules may overcome these obstacles. An immunostealth recombinant viral capsid protein (VP28) was expressed and conjugated with heparin to form a novel nanoparticle (VP28-heparin). VP28-heparin was characterized and tested to determine its immunogenicity, anticoagulation properties, effects on total platelet count, and risk of inducing HIT in animal models. The synthesized VP28-heparin trimeric nanoparticle was non-immunogenic, possessed an average hydrodynamic size (8.81 ± 0.58 nm) optimal for the evasion renal filtration and reticuloendothelial system uptake (hence prolonging circulating half-life). Additionally, VP28-heparin did not induce mouse death or reduce blood platelet count when administered at a high dosein vivo(hence reducing HIT risks). The VP28-heparin nanoparticle also exhibited superior anticoagulation properties (2.2× higher prothrombin time) and comparable activated partial thromboplastin time, but longer anticoagulation period when compared to unfractionated heparin. The anticoagulative effects of the VP28-heparin can also be reversed using protamine sulfate. Thus, VP28-heparin may be an effective and safe heparin derivative for therapeutic use.


Assuntos
Heparina , Trombocitopenia , Animais , Camundongos , Heparina/farmacologia , Heparina/uso terapêutico , Anticoagulantes/farmacologia , Coagulação Sanguínea , Trombocitopenia/tratamento farmacológico , Contagem de Plaquetas
5.
Scand J Clin Lab Invest ; : 1-4, 2024 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-39180490

RESUMO

It is common practice in laboratories to store biological samples in ultra-low temperature (ULT) freezers. There is growing interest in raising the temperature of ULT freezers in order to save energy and reduce expenses, as energy conservation becomes increasingly important and sustainable laboratory practices gain popularity. In our laboratory, plasma samples are stored for three months for diagnostic purposes. We therefore took the opportunity to investigate the effect of two different storage temperatures (-70 °C vs -80 °C), on activated partial thromboplastin time (APTT), factor VIII (FVIII), international normalized ratio (INR) and factor VII (FVII) measurements on paired plasma samples collected from 26 individuals after three months of storage. Automated coagulation analysers CS-5100 and ACL TOP were used to perform the tests. We found no consistent difference between the two storage temperatures for any of the four coagulation parameters (all p-values > 0.05). We conclude that the temperature of ULT freezers used to store plasma samples for APTT, FVIII, INR, and FVII measurements can be safely increased from -80 to -70 °C without affecting the stability of the samples.

6.
Int J Mol Sci ; 25(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38612796

RESUMO

The development of novel anticoagulants requires a comprehensive investigational approach that is capable of characterizing different aspects of antithrombotic activity. The necessary experiments include both in vitro assays and studies on animal models. The required in vivo approaches include the assessment of pharmacokinetic and pharmacodynamic profiles and studies of hemorrhagic and antithrombotic effects. Comparison of anticoagulants with different mechanisms of action and administration types requires unification of the experiment scheme and its adaptation to existing laboratory conditions. The rodent thrombosis models in combination with the assessment of hemostasis parameters and hematological analysis are the classic methods for conducting preclinical studies. We report an approach for the comparative study of the activity of different anticoagulants in vivo, including the investigation of pharmacodynamics and the assessment of hemorrhagic effects (tail-cut bleeding model) and pathological thrombus formation (inferior vena cava stenosis model of venous thrombosis). The reproducibility and uniformity of our set of experiments were illustrated on unfractionated heparin and dabigatran etexilate (the most common pharmaceuticals in antithrombic therapy) as comparator drugs and an experimental drug variegin from the tick Amblyomma variegatum. Variegin is notorious since it is a potential analogue of bivalirudin (Angiomax, Novartis AG, Basel, Switzerland), which is now being actively introduced into antithrombotic therapy.


Assuntos
Anticoagulantes , Heparina , Animais , Preparações Farmacêuticas , Anticoagulantes/farmacologia , Anticoagulantes/uso terapêutico , Heparina/farmacologia , Heparina/uso terapêutico , Fibrinolíticos/farmacologia , Fibrinolíticos/uso terapêutico , Reprodutibilidade dos Testes
7.
Heart Lung Circ ; 33(7): 975-982, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38575436

RESUMO

BACKGROUND: Evidence supporting anticoagulation with unfractionated heparin (UFH) in patients with an intra-aortic balloon pump (IABP) to prevent limb ischaemia remains limited, while bleeding risks remain high. Monitoring heparin in this setting with anti-factor Xa (anti-Xa) is not previously described. OBJECTIVES: The study objective is to describe the incidence of thromboembolic and bleeding events with the use of UFH in patients with an IABP utilising monitoring with both anti-Xa and activated partial thromboplastin time (aPTT). METHODS: This is a retrospective study of adults who received an IABP and UFH for ≥24 hours. Electronic medical records were reviewed for pertinent data. The primary outcome was the incidence of limb ischaemia during IABP. Secondary outcomes included myocardial infarction, thrombus on IABP, or stroke. Exploratory outcomes included any venous thromboembolism and bleeding events. RESULTS: Of 159 patients, 88% received an IABP for cardiogenic shock and median duration of IABP support was 118 hours (interquartile range, 67-196). Limb ischaemia occurred in four of 159 patients (2.5%). Strokes occurred in 3.8% of the cohort, and bleeding events occurred in 33%. Despite anticoagulation use in all patients, 11% experienced a venous thromboembolism, with most identified upon asymptomatic screening with concern for heparin-induced thrombocytopenia. We found no differences in outcomes that occurred with a hybrid anti-Xa and aPTT versus aPTT monitoring alone. CONCLUSIONS: We observed a high rate of thrombotic and bleeding complications with the use of UFH in patients with an IABP. Use of anti-Xa versus aPTT for monitoring was not associated with complications. These data suggest safer anticoagulation strategies are needed in this setting.


Assuntos
Heparina , Balão Intra-Aórtico , Humanos , Heparina/efeitos adversos , Heparina/administração & dosagem , Balão Intra-Aórtico/métodos , Balão Intra-Aórtico/efeitos adversos , Estudos Retrospectivos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Choque Cardiogênico , Incidência , Anticoagulantes/efeitos adversos , Anticoagulantes/administração & dosagem , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia
8.
Haemophilia ; 29(1): 329-335, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36137299

RESUMO

INTRODUCTION: Emicizumab markedly shortens the activated partial thromboplastin time (aPTT), resulting in inaccurate measurements of procoagulant and anticoagulant factor activities. We have recently reported that mixtures of two different anti-idiotype monoclonal antibodies against emicizumab (anti-emicizumab-mAbs) allow measurement of factor (F)VIII activity (FVIII:C) and FVIII inhibitor in emicizumab-containing plasmas. It is unknown whether anti-emicizumab mAbs can work for other aPTT-based procoagulant and anticoagulant assays. AIM: To investigate whether anti-emicizumab mAbs were measured by all of the aPTT-based assays tested. METHODS: Two anti-emicizumab-mAbs (300 µg/mL each) were preincubated with emicizumab (200 µg/mL)-spiked FVIII-deficient plasma; we then measured FVIII:C, FIX:C, FXI:C, FXII:C, protein (P)C:C, PS:C, global PC-FV (aPTT-based), and prothrombin time (PT), diluted Russel's viper venom time (dRVVT), chromogenic-based FVIII:C, FIX:C and PC:C (non-aPTT-based). Emicizumab (100 µg/mL)-spiked haemophilia (H)A plasmas from patients (n = 23) were also measured. RESULTS: Emicizumab shortened the clotting time in all aPTT-based assays, resulting in high levels of FVIII:C, FIX:C, FXI:C and FXII:C; low levels of PC:C and PS:C; and false-positive results for activated PC resistance. The addition of anti-emicizumab-mAbs to emicizumab-added plasma restored all factors to the initial levels without emicizumab. Chromogenic FVIII:C measurement by human FIXa/FX was affected by emicizumab, but anti-emicizumab mAbs cancelled this effect. PT-based assays and dRVVT, chromogenic FIX:C and PC:C assays showed no effect with emicizumab. Twenty-three plasma samples from HA patients also showed similar patterns. CONCLUSION: Anti-emicizumab mAbs in vitro could cancel the effect of emicizumab, irrespective of the test base, resulting in accurate measurements of procoagulant and anticoagulant factor activity.


Assuntos
Anticorpos Biespecíficos , Hemofilia A , Humanos , Coagulação Sanguínea , Anticoagulantes/farmacologia , Anticoagulantes/uso terapêutico , Tempo de Tromboplastina Parcial , Testes de Coagulação Sanguínea/métodos , Anticorpos Biespecíficos/farmacologia , Anticorpos Biespecíficos/uso terapêutico , Fator VIII/farmacologia
9.
Eur J Vasc Endovasc Surg ; 65(3): 398-404, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36343749

RESUMO

OBJECTIVE: Regular measurement of fibrinogen as dose guidance in catheter directed thrombolysis (CDT) for acute limb ischaemia (ALI) has recently been dropped from European guidelines based on inconsistent literature. This study aimed to determine whether low fibrinogen levels and high activated partial thromboplastin time (APTT) are associated with an increased major bleeding risk during CDT. METHODS: All consecutive patients treated with CDT for ALI in two Dutch hospitals between January 2004 and April 2021 were analysed retrospectively. Patients were treated with two dosing regimens (low dose: 50 000 IU/hour; high dose: 100 000 IU/hour) of urokinase and, after 2018, with a single low dose regimen of alteplase (rtPA) due to urokinase manufacturing problems. The incidence of major bleeding and associated APTT and fibrinogen levels were reviewed from patient charts. RESULTS: Of the 443 included cases, 277 underwent CDT with urokinase and 166 with rtPA. The incidence of major bleeding in the whole cohort was 7%. Patients with a fibrinogen levels < 1.0 g/L developed more major bleeding than those in whom the fibrinogen level did not drop below 1.0 g/L (15% vs. 6%; p = .041). Systemic heparinisation during CDT or high (> 80 seconds) APTT were not significantly associated with major bleeding. Angiographic success (47% vs. 72%; p = .003) and 30 day amputation free survival (53% vs. 82%; p < .001) were lower for cases with major bleeding. Older age (odds ratio [OR] 1.06, 95% confidence interval [CI] 1.02 - 1.11), cardiac history (OR 3.35, 95% CI 1.39 - 8.06), high dose regimens (≥ 75 000 IU/hour urokinase; OR 2.67, 95% CI 1.18 - 6.04), and fibrinogen values < 1.0 g/L (OR 5.59, 95% CI 1.98 - 15.77) were independent predictors for major bleeding during CDT. CONCLUSION: High dose thrombolytic regimens and fibrinogen levels of ≤ 1.0 g/L are associated with more major bleeding during thrombolytic therapy. Major bleeding significantly worsened the clinical outcome. A prospective comparative study is needed to assess the benefit of monitoring fibrinogen levels.


Assuntos
Arteriopatias Oclusivas , Doenças Vasculares Periféricas , Humanos , Ativador de Plasminogênio Tipo Uroquinase , Estudos Retrospectivos , Estudos Prospectivos , Terapia Trombolítica/efeitos adversos , Fibrinolíticos , Ativador de Plasminogênio Tecidual , Arteriopatias Oclusivas/etiologia , Isquemia/etiologia , Hemorragia/etiologia , Doenças Vasculares Periféricas/complicações , Fibrinogênio , Tomada de Decisão Clínica , Resultado do Tratamento
10.
Mar Drugs ; 21(11)2023 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-37999392

RESUMO

Fucosylated glycosaminoglycans (FGs) derived from sea cucumbers exhibit potent intrinsic Xase (iXase) inhibition, anticoagulation, and antithrombosis. Plasma activated partial thromboplastin time (APTT), a widely used screening test worldwide, is crucial for evaluating anticoagulant efficacy. However, the applicability of these commercially available APTT reagents for assessing anticoagulation of FGs remains unreported. In this study, we investigated the disparity between ellagic acid and colloidal silica APTT reagents in evaluating anticoagulation of dHG-5 and dHLFG-4, two depolymerized FGs, and elucidated the underlying rationale. The results demonstrated that dHG-5 and dHLFG-4 exhibited heightened sensitivity to the ellagic acid APTT reagent both in vitro and in vivo, and did not significantly affect the activation of APTT reagents for plasma. In addition, both ellagic acid and colloidal silica APTT reagents inhibited the anti-iXase of dHG-5 and dHLFG-4, and the inhibition of the ellagic acid APTT reagent was less pronounced compared to the colloidal silica APTT reagent. These findings suggest that the reduced impact of the ellagic acid APTT reagent on the anti-iXase activity of dHG-5 and dHLFG-4 is responsible for the increased sensitivity in plasma APTT analysis. This study offers valuable insights into the characteristics of two APTT reagents applied for assessing the anticoagulant activity of FG-related compounds.


Assuntos
Anticoagulantes , Pepinos-do-Mar , Animais , Anticoagulantes/farmacologia , Tempo de Tromboplastina Parcial , Glicosaminoglicanos/farmacologia , Indicadores e Reagentes , Ácido Elágico , Dióxido de Silício
11.
Medicina (Kaunas) ; 59(6)2023 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-37374373

RESUMO

Activated partial thromboplastin time (aPTT) is a fundamental screening test for coagulation disturbances. An increased aPTT ratio is quite common in clinical practice. How the detection of prolonged activated aPTT with a normal prothrombin time is interpreted is therefore very important. In daily practice, the detection of this abnormality often leads to delayed surgery and emotional stress for patients and their families and may be associated with increased costs due to re-testing and coagulation factor assessment. An isolated, prolonged aPTT is seen in (a) patients with congenital or acquired deficiencies of specific coagulation factors, (b) patients receiving treatment with anticoagulants, mainly heparin, and (c) individuals/patients with circulating anticoagulants. We summarize here what may cause an isolated prolonged aPTT and evaluate the preanalytical interferences. The identification of the cause of an isolated prolonged aPTT is of the utmost importance in ensuring the correct diagnostic workup and therapeutic choices.


Assuntos
Transtornos da Coagulação Sanguínea , Coagulação Sanguínea , Humanos , Tempo de Tromboplastina Parcial , Testes de Coagulação Sanguínea , Tempo de Protrombina , Fatores de Coagulação Sanguínea , Anticoagulantes/uso terapêutico , Hemorragia
12.
J Avian Med Surg ; 36(4): 356-361, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36935206

RESUMO

Objective assessment of coagulation in birds is difficult, and traditional methods of measuring prothrombin time (PT) and activated partial thromboplastin time (aPTT) with the use of mammalian reagents have not been validated in birds. Avian-specific reagents must be prepared from brain extract and are not practical for clinical use. The objective of this investigation was to determine whether the InSight qLabs point-of-care analyzer (Micropoint Biotechnologies Inc, Guangdong, China) could measure PT and aPTT in Hispaniolan Amazon parrots (Amazona ventralis) in native and citrated whole blood, and whether the values obtained correlated with clinical appearance and basic hematologic and biochemical parameters from the bird. The qLabs analyzer was able to measure aPTT reliably, but not PT. Activated partial thromboplastin time of citrated blood was significantly different from the aPTT measured from native whole blood (P < 0.001). On the basis of this study, the qLabs machine may be used to measure aPTT, but clinical application between avian species requires further research.


Assuntos
Amazona , Animais , Tempo de Protrombina/veterinária , Tempo de Tromboplastina Parcial/veterinária , Sistemas Automatizados de Assistência Junto ao Leito , Citratos , Ácido Cítrico , Mamíferos
13.
Pak J Med Sci ; 39(3): 795-798, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37250575

RESUMO

Objective: To evaluate the efficacy of hematological parameters to predict severity of COVID-19 patients. Method: This was a cross-sectional comparative study conducted at Central Park Teaching Hospital, Lahore in COVID ward and COVID ICU between April 23, 2021 to June 23, 2021. Patients of all ages and both genders with positive PCR admitted in the COVID ward and ICU during this time span of two months were included in the study. Data was collected retrospectively. Results: This study included 50 patients with male to female ratio of 1.38:1. Though males are more affected by COVID-19 but the difference is not statistically significant. The mean age of the study population was 56.21 and the patients in the severe disease group have higher age. It was observed that in severe/critical group the mean values of total leukocyte count 21.76×103 µI (p-value= 0.002), absolute neutrophil count 71.37% (p-value=0.045), neutrophil lymphocyte ratio (NLR) 12.80 (p-value=0.00) and PT 11.9 seconds (p-value=0.034) and the difference was statistically significant. While in severe/critical group, the mean values of hemoglobin 12.03g/dl (p-value=0.075), lymphocyte count 28.41% (p-value=0.8), platelet count 226×103 µI (p-value=0.67) and APTT 30.7 (p-value=0.081) and the difference was not significantly different between groups. Conclusion: It can be concluded from the study that total leucocyte count, absolute neutrophil count and neutrophil lymphocyte ratio can predict in-hospital mortality and morbidity in COVID-19 patients.

14.
Transfusion ; 62(11): 2223-2234, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36250486

RESUMO

INTRODUCTION: Preoperative coagulation screening for patients without bleeding disorders remains controversial. The combinatorial risk of INR, aPTT, and platelet count (PLT) abnormalities leading to bleeding requiring transfusion is not known in these patients. We examined the association between abnormal coagulation profile and the risk of transfusion following common elective surgery in patients without bleeding disorders. STUDY DESIGN AND METHODS: We utilized the National Surgical Quality Improvement Program (NSQIP) database from 2004 to 2018 to identify patients without a history of bleeding disorders undergoing common 23 major elective procedures across 10 specialties. Multivariable logistic regression was used to assess the association between coagulation profile and bleeding requiring packed red blood cell transfusion intra-/post-operatively. RESULTS: Of the 672,075 patients meeting inclusion criteria, 53.7% presented with normal coagulation profile preoperatively. Overall, 12.2% (n = 82,368) received transfusion. In the setting of normal aPTT/PLT, both Equivocal INR of 1.1-1.5 (aOR 1.41, 95% CI 1.38-1.44) and Abnormal INR of >1.5 (aOR 1.81, 95% CI 1.71-1.93) were significantly associated with an increased risk of transfusion. Equivocal (60-70) and Abnormal (>70) aPTT with normal INR/PLT did not demonstrate a comparable risk of transfusion. We observed a synergistic effect of combinatorial lab abnormalities on the risk of transfusion when both Abnormal INR/aPTT and Low PLT of <100,000 were present (aOR 5.18, 95% CI 3.04-8.84), compared to the effect of Abnormal INR/aPTT and normal/elevated PLT (aOR 1.90, 95% CI 1.48-2.45). DISCUSSION: The preoperative presence of abnormal findings in INR or PLT was significantly associated with the risk of bleeding requiring transfusion during intraoperative and postoperative periods.


Assuntos
Transtornos da Coagulação Sanguínea , Melhoria de Qualidade , Humanos , Transtornos da Coagulação Sanguínea/terapia , Transtornos da Coagulação Sanguínea/complicações , Transfusão de Sangue , Tempo de Tromboplastina Parcial , Hemorragia/etiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos
15.
Artif Organs ; 46(3): 501-505, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34698388

RESUMO

BACKGROUND: Sheep are a primary model of mechanical circulatory support (MCS) with heparin anticoagulation therapy frequently being monitored by activated clotting time (ACT) due to ease and cost. In patients undergoing long-term heparin therapy, other anticoagulation monitoring strategies, such as activated partial thromboplastin time (aPTT), have proven to be more reliable indicators for the adequacy of anticoagulation, frequently determined by heparin concentration. As there is a paucity of similar studies in sheep, we sought to investigate the correlation between heparin concentration and ACT and aPTT using whole sheep blood in an ex vivo model. METHODS: Fresh whole blood was serially drawn from an adult female Dorset-hybrid sheep and aliquots were placed into tubes containing heparin saline solutions with concentrations ranging from 0 to 7.81 U heparin per mL of whole blood. ACT and aPTT values were measured on each of the samples. The experiment was performed four times with the same animal. A simple linear regression was performed to determine correlation, and subgroup analysis was performed on low versus high heparin concentrations typically seen in human patients on long-term MCS, such as extracorporeal membrane oxygenation (ECMO), versus cardiopulmonary bypass, respectively. RESULTS: aPTT measurements versus the heparin concentration had an R2  = 0.7295. ACT measurements versus the heparin concentration had a R2  = 0.4628. aPTT measurements versus the ACT measurements had a R2  = 0.2974. The strength of the correlation between aPTT and heparin concentration increased at low heparin concentrations (R2  = 0.8392). CONCLUSION: aPTT had a more reliable correlation to heparin concentration and thus anticoagulation level than ACT. This was particularly true at lower heparin concentrations, similar to ranges seen for patients on ECMO. The correlation between aPTT and ACT values was poor. Further in vivo studies should be performed to confirm our results.


Assuntos
Anticoagulantes/administração & dosagem , Heparina/administração & dosagem , Tempo de Tromboplastina Parcial , Tempo de Coagulação do Sangue Total , Animais , Relação Dose-Resposta a Droga , Modelos Lineares , Modelos Animais , Ovinos
16.
Artif Organs ; 46(9): 1901-1911, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35451086

RESUMO

BACKGROUND: Bleeding complications during venovenous extracorporeal membrane oxygenation (V-V ECMO) can be critical. However, there is limited information on the associated risk factors. This study investigated the risk factors for bleeding complications during V-V ECMO as a bridge to recovery. METHODS: This single-center retrospective study enrolled 59 patients (bleeding and non-bleeding groups) who received V-V ECMO from 2012 to 2020, to evaluate whether peak activated partial thromboplastin time (APTT) value, lowest platelet count, and mobilization to sitting on the edge of the bed during V-V ECMO were risk factors for bleeding complications, defined according to the Extracorporeal Life Support Organization guidelines. Age, sex, body mass index, Sequential Organ Failure Assessment score, and ECMO duration before bleeding complications were covariates in the multivariate logistic regression analysis. RESULTS: Thirty-one (53%) participants experienced 36 bleeding complications; the ECMO cannulation site, gastrointestinal tract, and nasopharyngeal region were the most common bleeding sites. The use of transfusion products and length of ECMO and intensive care unit stay were significantly and medical costs were non-significantly increased in the bleeding group. Peak APTT (odds ratio [OR] 1.03, 95% confidence interval [CI] 1.01-1.05, p < 0.01) was significantly associated whereas the lowest platelet count (OR 0.96, 95% CI 0.82-1.13, p = 0.66) was unassociated with bleeding complications during ECMO. Achieving mobilization (OR 0.14, 95% CI 0.02-1.17, p = 0.07) decreased the trend of risk for bleeding complications. CONCLUSIONS: Peak APTT might be an independent modifiable factor for bleeding complications during V-V ECMO. The protective effect of mobilization during V-V ECMO requires further investigation.


Assuntos
Oxigenação por Membrana Extracorpórea , Oxigenação por Membrana Extracorpórea/efeitos adversos , Hemorragia/etiologia , Hemorragia/terapia , Humanos , Estudos Retrospectivos , Fatores de Risco
17.
Langenbecks Arch Surg ; 407(6): 2309-2317, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35482049

RESUMO

BACKGROUND: Anastomotic leakage (AL) is a major complication after esophagectomy, potentiating morbidity and mortality. There are several patient risk factors associated with AL, but high-fidelity postoperative predictors are still under debate. The aim was to identify novel reliable predictors for AL after esophagectomy. METHODS: A high-volume single-center database study, including 138 patients receiving Ivor-Lewis-esophagectomy between 2017 and 2019, was performed. Serum levels of albumin, aPTT, and lactate before and after surgery were extracted to assess their impact on AL and in-hospital mortality. RESULTS: High serum lactate on postoperative day 1 (POD1) could be shown to predict AL after esophagectomy [AL vs. no AL: 1.2 (0.38) vs. 1.0 (0.37); p < 0.001]. Accordingly, also differences of serum lactate level between end (POD0-2) and start of surgery (POD0-1) (p < 0.001) as well as between POD1 and POD0-1 (p < 0.001) were associated with AL. Accordingly, logistic regression identified serum lactate on POD 1 as an independent predictor of AL [HR: 4.37 (95% CI: 1.28-14.86); p = 0.018]. Further, low serum albumin on POD0 [2.6 (0.53) vs. 3.1 (0.56); p = 0.001] and high serum lactate on POD 0-1 [1.1 (0.29) vs. 0.9 (0.30); p = 0.043] were associated with in-hospital death. Strikingly, logistic-regression (HR: 0.111; p = 0.008) and cox-regression analysis (HR: 0.118; p = 0.003) showed low serum albumin as an independently predictor for in-hospital death after esophagectomy. CONCLUSIONS: This study identified high serum lactate as an independent predictor of AL and low serum albumin as a high-fidelity predictor of in-hospital death after esophagectomy. These parameters can facilitate improved postoperative treatment leading to better short-term as well as long-term outcomes.


Assuntos
Neoplasias Esofágicas , Esofagectomia , Fístula Anastomótica/etiologia , Neoplasias Esofágicas/cirurgia , Esofagectomia/efeitos adversos , Mortalidade Hospitalar , Humanos , Lactatos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Albumina Sérica
18.
J Clin Lab Anal ; 36(9): e24608, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35853032

RESUMO

BACKGROUND: For the lack of standardized activated partial thromboplastin time (APTT), it has been pointed out that there are differences in values among several reagents. Recently, we have performed a parallel measurement on two reagents, Thrombocheck APTT-SLA and Coagpia APTT-n, and resulted with some dissociated samples. The purpose of this study is to clarify the possible factors related to ΔAPTT, the difference in measured values between the two reagents. MATERIALS AND METHODS: In order to clarify the factors related to ΔAPTT, multiple regression analysis was performed on 8324 samples, using clinical laboratory data of all test items requested simultaneously with APTT. To confirm the items extracted from the multiple regression analysis, the target substance was spiked to pooled plasma and measured with two APTT reagents. Additionally, by spiking phospholipids, the effect on APTT measurement system was assessed. RESULT: Multiple regression analysis detected albumin-globulin ratio (AGR), C-reactive protein (CRP), hematocrit, and prothrombin time as factors related to ΔAPTT (p < 0.001). Results revealed no significant differences when albumin was added to change the AGR. Whereas with the addition of CRP, prolongation of APTT was observed in Coagpia APTT-n compared to Thrombocheck APTT-SLA (p < 0.001). This prolongation was canceled by the addition of phospholipids, suggesting the interaction of CRP with phospholipids leads to the pseudo-prolongation. CONCLUSION: It is considered that the pseudo-prolongation of APTT is triggered by the interaction of CRP on the phospholipid in Coagpia APTT-n, which contributed to the APTT dissociation.


Assuntos
Albuminas , Fosfolipídeos , Testes de Coagulação Sanguínea , Humanos , Indicadores e Reagentes , Tempo de Tromboplastina Parcial , Tempo de Protrombina
19.
BMC Oral Health ; 22(1): 69, 2022 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-35282827

RESUMO

BACKGROUND: Uncontrollable bleeding after tooth extraction usually occurs in patients with coagulation diseases, including hemophilia, von Willebrand's disease, vitamin K deficiency, platelet deficiency, and taking anticoagulant drugs. Hemophilia A is an X-linked recessive disorder caused by insufficiency of coagulation factor VIII. Mild hemophilia, defined by factor level between 0.05 and 0.40 IU/mL, is characterized by uncontrollable hemorrhage after trauma or invasive operations. Some mild hemophiliacs may remain undiagnosed until late adulthood. Therefore, surgical management of these patients may be relatively neglected. These case reports describe two uncontrollable bleeding patients with unknown mild hemophilia A after tooth extraction. CASE PRESENTATION: This paper reports 2 cases of persistent bleeding after tooth extraction under local anesthesia which could not be completely stopped by routine treatments. Both of them denied prior illness and injury, allergies, anticoagulant medication history, systemic and family illness. The APTT and other coagulation screening tests of the two patients before surgery were normal. Finally, they were diagnosed with mild hemophilia A via coagulation factor assays. The patients acquired complete hemostasis by receiving coagulation factor supplement therapy in hematologic department. CONCLUSION: Mild hemophilia is marked by subclinical, asymptomatic and even normal coagulation test results. The purpose of these case reports is to bring dental professionals' attention that APTT test alone cannot be used to exclude mild hemophilia, and provide reasonable evaluation and treatment procedures of bleeding patients after tooth extraction.


Assuntos
Hemofilia A , Doenças de von Willebrand , Adulto , Plaquetas , Hemofilia A/complicações , Hemofilia A/diagnóstico , Hemorragia/etiologia , Hemorragia/prevenção & controle , Humanos , Extração Dentária/efeitos adversos , Doenças de von Willebrand/diagnóstico , Doenças de von Willebrand/tratamento farmacológico
20.
Medicina (Kaunas) ; 58(12)2022 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-36556985

RESUMO

Extracorporeal membrane oxygenation (ECMO) has been established as a life-saving technique for patients with the most severe forms of respiratory or cardiac failure. It can, however, be associated with severe complications. Anticoagulation therapy is required to prevent ECMO circuit thrombosis. It is, however, associated with an increased risk of hemocoagulation disorders. Thus, safe anticoagulation is a cornerstone of ECMO therapy. The most frequently used anticoagulant is unfractionated heparin, which can, however, cause significant adverse effects. Novel drugs (e.g., argatroban and bivalirudin) may be superior to heparin in the better predictability of their effects, functioning independently of antithrombin, inhibiting thrombin bound to fibrin, and eliminating heparin-induced thrombocytopenia. It is also necessary to keep in mind that hemocoagulation tests are not specific, and their results, used for setting up the dosage, can be biased by many factors. The knowledge of the advantages and disadvantages of particular drugs, limitations of particular tests, and individualization are cornerstones of prevention against critical events, such as life-threatening bleeding or acute oxygenator failure followed by life-threatening hypoxemia and hemodynamic deterioration. This paper describes the effects of anticoagulant drugs used in ECMO and their monitoring, highlighting specific conditions and factors that might influence coagulation and anticoagulation measurements.


Assuntos
Oxigenação por Membrana Extracorpórea , Heparina , Humanos , Heparina/efeitos adversos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Anticoagulantes/efeitos adversos , Antitrombinas/uso terapêutico , Coagulação Sanguínea , Estudos Retrospectivos