Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 273
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Gastroenterology ; 164(6): 906-920, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36736437

RESUMO

BACKGROUND & AIMS: The use of computer-aided detection (CAD) increases the adenoma detection rates (ADRs) during colorectal cancer (CRC) screening/surveillance. This study aimed to evaluate the requirements for CAD to be cost-effective and the impact of CAD on adenoma detection by endoscopists with different ADRs. METHODS: We developed a semi-Markov microsimulation model to compare the effectiveness of traditional colonoscopy (mean ADR, 26%) to colonoscopy with CAD (mean ADR, 37%). CAD was modeled as having a $75 per-procedure cost. Extensive 1-way sensitivity and threshold analysis were performed to vary cost and ADR of CAD. Multiple scenarios evaluated the potential effect of CAD on endoscopists' ADRs. Outcome measures were reported in incremental cost-effectiveness ratios, with a willingness-to-pay threshold of $100,000/quality-adjusted life year. RESULTS: When modeling CAD improved ADR for all endoscopists, the CAD cohort had 79 and 34 fewer lifetime CRC cases and deaths, respectively, per 10,000 persons. This scenario was dominant with a cost savings of $143 and incremental effectiveness of 0.01 quality-adjusted life years. Threshold analysis demonstrated that CAD would be cost-effective up to an additional cost of $579 per colonoscopy, or if it increases ADR from 26% to at least 30%. CAD reduced CRC incidence and mortality when limited to improving ADRs for low-ADR endoscopists (ADR <25%), with 67 fewer CRC cases and 28 CRC deaths per 10,000 persons compared with traditional colonoscopy. CONCLUSIONS: As CAD is implemented clinically, it needs to improve mean ADR from 26% to at least 30% or cost less than $579 per colonoscopy to be cost-effective when compared with traditional colonoscopy. Further studies are needed to understand the impact of CAD when used in community practice.


Assuntos
Adenoma , Neoplasias Colorretais , Humanos , Análise Custo-Benefício , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/epidemiologia , Adenoma/diagnóstico , Detecção Precoce de Câncer , Computadores
2.
Clin Gastroenterol Hepatol ; 22(3): 630-641.e4, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37918685

RESUMO

BACKGROUND: The effect of computer-aided polyp detection (CADe) on adenoma detection rate (ADR) among endoscopists-in-training remains unknown. METHODS: We performed a single-blind, parallel-group, randomized controlled trial in Hong Kong between April 2021 and July 2022 (NCT04838951). Eligible subjects undergoing screening/surveillance/diagnostic colonoscopies were randomized 1:1 to receive colonoscopies with CADe (ENDO-AID[OIP-1]) or not (control) during withdrawal. Procedures were performed by endoscopists-in-training with <500 procedures and <3 years' experience. Randomization was stratified by patient age, sex, and endoscopist experience (beginner vs intermediate level, <200 vs 200-500 procedures). Image enhancement and distal attachment devices were disallowed. Subjects with incomplete colonoscopies or inadequate bowel preparation were excluded. Treatment allocation was blinded to outcome assessors. The primary outcome was ADR. Secondary outcomes were ADR for different adenoma sizes and locations, mean number of adenomas, and non-neoplastic resection rate. RESULTS: A total of 386 and 380 subjects were randomized to CADe and control groups, respectively. The overall ADR was significantly higher in the CADe group than in the control group (57.5% vs 44.5%; adjusted relative risk, 1.41; 95% CI, 1.17-1.72; P < .001). The ADRs for <5 mm (40.4% vs 25.0%) and 5- to 10-mm adenomas (36.8% vs 29.2%) were higher in the CADe group. The ADRs were higher in the CADe group in both the right colon (42.0% vs 30.8%) and left colon (34.5% vs 27.6%), but there was no significant difference in advanced ADR. The ADRs were higher in the CADe group among beginner (60.0% vs 41.9%) and intermediate-level (56.5% vs 45.5%) endoscopists. Mean number of adenomas (1.48 vs 0.86) and non-neoplastic resection rate (52.1% vs 35.0%) were higher in the CADe group. CONCLUSIONS: Among endoscopists-in-training, the use of CADe during colonoscopies was associated with increased overall ADR. (ClinicalTrials.gov, Number: NCT04838951).


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Pólipos , Humanos , Neoplasias Colorretais/diagnóstico , Método Simples-Cego , Colonoscopia/métodos , Adenoma/diagnóstico , Computadores , Pólipos do Colo/diagnóstico
3.
Artigo em Inglês | MEDLINE | ID: mdl-38437999

RESUMO

BACKGROUND & AIMS: The use of computer-aided detection (CADe) has increased the adenoma detection rates (ADRs) during colorectal cancer (CRC) screening/surveillance in randomized controlled trials (RCTs) but has not shown benefit in real-world implementation studies. We performed a single-center pragmatic RCT to evaluate the impact of real-time CADe on ADRs in colonoscopy performed by community gastroenterologists. METHODS: We enrolled 1100 patients undergoing colonoscopy for CRC screening, surveillance, positive fecal-immunohistochemical tests, and diagnostic indications at one community-based center from September 2022 to March 2023. Patients were randomly assigned (1:1) to traditional colonoscopy or real-time CADe. Blinded pathologists analyzed histopathologic findings. The primary outcome was ADR (the percentage of patients with at least 1 histologically proven adenoma or carcinoma). Secondary outcomes were adenomas detected per colonoscopy (APC), sessile-serrated lesion detection rate, and non-neoplastic resection rate. RESULTS: The median age was 55.5 years (interquartile range, 50-62 years), 61% were female, 72.7% were of Hispanic ethnicity, and 9.1% had inadequate bowel preparation. The ADR for the CADe group was significantly higher than the traditional colonoscopy group (42.5% vs 34.4%; P = .005). The mean APC was significantly higher in the CADe group compared with the traditional colonoscopy group (0.89 ± 1.46 vs 0.60 ± 1.12; P < .001). The improvement in adenoma detection was driven by increased detection of <5 mm adenomas. CADe had a higher sessile-serrated lesion detection rate than traditional colonoscopy (4.7% vs 2.0%; P = .01). The improvement in ADR with CADe was significantly higher in the first half of the study (47.2% vs 33.7%; P = .002) compared with the second half (38.7% vs 34.9%; P = .33). CONCLUSIONS: In a single-center pragmatic RCT, real-time CADe modestly improved ADR and APC in average-detector community endoscopists. (ClinicalTrials.gov number, NCT05963724).

4.
Scand J Gastroenterol ; : 1-8, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38850200

RESUMO

BACKGROUND AND STUDY AIMS: Long-time follow-up of sigmoidoscopy screening trials has shown reduced incidence and mortality of colorectal cancer (CRC), but inadequate bowel cleansing may hamper efficacy. The aim of this study was to assess the impact of bowel cleansing quality in sigmoidoscopy screening. PATIENTS AND METHODS: Individuals 50 to 74 years old who had a screening sigmoidoscopy in a population-based Norwegian, randomized trial between 2012 and 2019, were included in this cross-sectional study. The bowel cleansing quality was categorised as excellent, good, partly poor, or poor. The effect of bowel cleansing quality on adenoma detection rate (ADR) and referral to colonoscopy was evaluated by fitting multivariable logistic regression models. RESULTS: 35,710 individuals were included. The bowel cleansing at sigmoidoscopy was excellent in 20,934 (58.6%) individuals, good in 6580 (18.4%), partly poor in 7097 (19.9%) and poor in 1099 (3.1%). The corresponding ADRs were 17.0%, 16.6%, 14.5%, and 13.0%. Compared to participants with excellent bowel cleansing, those with poor bowel cleansing had an odds ratio for adenoma detection of 0.66 (95% confidence interval 0.55-0.79). We found substantial differences in the assessment of bowel cleansing quality among endoscopists. CONCLUSIONS: Inadequate bowel cleansing reduces the efficacy of sigmoidoscopy screening, by lowering ADR. A validated rating scale and improved bowel preparation are needed to make sigmoidoscopy an appropriate screening method.Trial registration Clinicaltrials.gov (NCT01538550).

5.
Scand J Gastroenterol ; : 1-11, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38775234

RESUMO

BACKGROUND: Adenoma detection rate (ADR) is higher after a positive fecal immunochemical test (FIT) compared to direct screening colonoscopy. OBJECTIVE: This meta-analysis evaluated how ADR, the rates of advanced adenoma detection (AADR), colorectal cancer detection (CDR), and sessile serrated lesion detection (SSLDR) are affected by different FIT positivity thresholds. METHODS: We searched MEDLINE, EMBASE, CINAHL, and EBM Reviews databases for studies reporting ADR, AADR, CDR, and SSLDR according to different FIT cut-off values in asymptomatic average-risk individuals aged 50-74 years old. Data were stratified according to sex, age, time to colonoscopy, publication year, continent, and FIT kit type. Study quality, heterogeneity, and publication bias were assessed. RESULTS: Overall, 4280 articles were retrieved and fifty-eight studies were included (277,661 FIT-positive colonoscopies; mean cecal intubation 96.3%; mean age 60.8 years; male 52.1%). Mean ADR was 56.1% (95% CI 53.4 - 58.7%), while mean AADR, CDR, and SSLDR were 27.2% (95% CI 24.4 - 30.1%), 5.3% (95% CI 4.7 - 6.0%), and 3.0% (95% CI 1.7 - 4.6%), respectively. For each 20 µg Hb/g increase in FIT cut-off level, ADR increased by 1.54% (95% CI 0.52 - 2.56%, p < 0.01), AADR by 3.90% (95% CI 2.76 - 5.05%, p < 0.01) and CDR by 1.46% (95% CI 0.66 - 2.24%, p < 0.01). Many detection rates were greater amongst males and Europeans. CONCLUSIONS: ADRs in FIT-positive colonoscopies are influenced by the adopted FIT positivity threshold, and identified targets, importantly, proved to be higher than most current societal recommendations.

6.
BMC Gastroenterol ; 24(1): 132, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609900

RESUMO

BACKGROUND: Different split regimens of polyethylene glycol are routinely used and no guidelines are available to select an optimal protocol of ingestion. This study aims to compare the efficacy and side effect profile of two different regimens of polyethylene glycol bowel preparation solution: PEG (3 + 1) vs. PEG (2 + 2). METHODS: 240 patients above the age of 18 years were included in the study between June 1st and November 31st, 2023. Patients were randomly assigned either to Group A, consisting of 115 patients receiving a 3 L of PEG the night before the colonoscopy, and 1 L the same morning of the procedure. Or to group B, where 125 patients ingested 2 L the night before the procedure, and the remaining 2 L the same morning. The cleansing efficacy was evaluated by the attending endoscopist using the Boston Bowel Preparation Scale, through a score assigned for each segment of the colon (0-3). Side effects, tolerability, and willingness to retake the same preparation were listed by an independent investigator using a questionnaire administered before the procedure. RESULTS: A higher percentage of patients had gastric fullness with the 3 + 1 vs. 2 + 2 preparation (58.3% vs. 31.2%; p <.001). A higher Boston bowel preparation score was seen in patients who took the 2 + 2 vs. 3 + 1 preparation (7.87 vs. 7.23). Using the 2 + 2 preparation was significantly associated with higher Boston bowel preparation scores vs. the 3 + 1 preparation (OR = 1.37, p =.001, 95% CI 1.14, 1.64). After adjustment over other variables (age, gender, comorbidities, previous abdominal surgeries, presence of adenoma, and time between last dose and colonoscopy), results remained the same (aOR = 1.34, p =.003, 95% CI 1.10, 1.62). CONCLUSION: While both (2 + 2) and (3 + 1) regimens of polyethylene glycol are a good choice for a successful colonoscopy, we recommend the use of (2 + 2) regimen for its superior efficacy in bowel cleansing.


Assuntos
Colonoscopia , Polietilenoglicóis , Humanos , Adolescente , Estudos Prospectivos , Protocolos Clínicos , Polietilenoglicóis/efeitos adversos , Estômago
7.
J Gastroenterol Hepatol ; 39(7): 1374-1381, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38602345

RESUMO

BACKGROUND AND AIM: Linked color imaging (LCI) is an image-enhanced endoscopy technique that accentuates the color difference between red and white, potentially improving the adenoma detection rate (ADR). However, it remains unclear whether LCI performance in detecting colorectal lesions differs based on endoscopists' experience levels. We aimed to evaluate the differences in LCI efficacy based on the experience levels of endoscopists by conducting an exploratory analysis. METHODS: In this post hoc analysis of an international randomized controlled trial comparing the detection of adenoma and other lesions using colonoscopy with LCI and high-definition white light imaging (WLI), we included patients from 11 institutions across four countries/regions: Japan, Thailand, Taiwan, and Singapore. We retrospectively reviewed differences in the lesion detection of LCI according to endoscopists' colonoscopy history or ADR. RESULTS: We included 1692 and 1138 patients who underwent colonoscopies performed by 54 experts (experience of ≥ 5000 colonoscopies) and by 43 non-experts (experience of < 5000 colonoscopies), respectively. Both expert and non-expert groups showed a significant improvement in ADR with LCI compared to WLI (expert, 61.7% vs 46.4%; P < 0.001; non-expert, 56.6% vs 46.4%; P < 0.001). LCI had no effect on sessile serrated lesion detection rate in non-experts (3.1% vs 2.5%; P = 0.518). LCI significantly improved detection rates in endoscopists with relatively low detection performance, defined as an ADR < 50%. CONCLUSIONS: This exploratory study analyzed data from a previous trial and revealed that LCI is useful for both experts and non-experts and is even more beneficial for endoscopists with relatively low detection performance using WLI.


Assuntos
Adenoma , Colonoscopia , Cor , Neoplasias Colorretais , Humanos , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/diagnóstico por imagem , Adenoma/diagnóstico por imagem , Adenoma/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Competência Clínica , Estudos Retrospectivos , Aumento da Imagem/métodos , Ásia
8.
J Gastroenterol Hepatol ; 39(3): 457-463, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37984841

RESUMO

BACKGROUND AND AIM: The purpose of this randomized controlled study was to compare the characteristics of the CF-H290I (high-definition) colonoscope with those of the PCF-Q260JI (high-resolution) colonoscope in non-sedated patients with a history of abdominal or pelvic surgery in an effort to help endoscopists to select more effectively and objectively between the various colonoscopes. METHODS: A total of 397 patients who underwent colonoscopy at the Affiliated Wuxi People's Hospital of Nanjing Medical University, between August 2022 and October 2022 were randomized to a CF-H290I group (n = 198) or a PCF-Q260JI group (n = 199) using a computer-generated allocation method. We compared the adenoma detection rate (ADR), patient satisfaction with the examination, discomfort associated with colonoscopy including abdominal distension and pain, cecal intubation time, and patient willingness to undergo colonoscopy in the future between the CF-H290I and PCF-Q260JI groups. RESULTS: There was no statistically significant difference in the overall ADR between the CF-H290I and PCF-Q260JI groups (81 [40.9%] vs 63 [31.7%], Z = 3.674, P = 0.055). However, the ADRs in the transverse colon and left colon were significantly higher in the CF-H290I group (22 [11.1%] vs 6 [3.0%], Z = 9.588, P = 0.002 and 57 [28.8%] vs 37 [18.6%], Z = 5.212, P = 0.017, respectively). More sessile serrated lesions were detected in the CF-H290I group (52 [26.3] vs 30 [15.1%], Z = 7.579, P = 0.006). Patient satisfaction with colonoscopy was better in the PCF-Q260JI group (8.91 ± 1.09 vs 8.51 ± 1.44, t = -3.158, P < 0.01) with less likelihood of discomfort (23 [11.6%] vs 41 [20.7%], Z = 6.144, P = 0.013), The number of patients willing to undergo colonoscopy in the future was significantly greater in the PCF-Q260JI group (168 [84.4%] vs 149 [75.3%], Z = 5.186, P = 0.023). The cecal intubation time was significantly shorter in the CF-H290I group (256.09 ± 155.70 s vs 315.64 ± 171.64 s, P = 0.004). There were no complications such as perforation or bleeding in either group. CONCLUSION: The CF-H290I and PCF-Q260JI colonoscopes each have advantages when used in patients with a history of abdominal or pelvic surgery. The CF-H290I has higher ADRs in the transverse and left colon whereas the PCF-Q260JI is less painful and better accepted by patients. This study was approved by the Clinical Research Ethics Committee of Wuxi People's Hospital and was registered in the Chinese Clinical Trial Registry (ChiCTR2200063092).


Assuntos
Adenoma , Colonoscopia , Humanos , Colonoscopia/efeitos adversos , Colonoscopia/métodos , Ceco , Estudos Prospectivos , Desenho de Equipamento , Colonoscópios/efeitos adversos , Dor/etiologia
9.
Dig Dis Sci ; 69(4): 1380-1388, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38436866

RESUMO

BACKGROUND AND AIMS: Screening colonoscopy has significantly contributed to the reduction of the incidence of colorectal cancer (CRC) and its associated mortality, with adenoma detection rate (ADR) as the quality marker. To increase the ADR, various solutions have been proposed including the utilization of Artificial Intelligence (AI) and employing second observers during colonoscopies. In the interest of AI improving ADR independently, without a second observer, and the operational similarity between AI and second observer, this network meta-analysis aims at evaluating the effectiveness of AI, second observer, and a single observer in improving ADR. METHODS: We searched the Medline, Embase, Cochrane, Web of Science Core Collection, Korean Citation Index, SciELO, Global Index Medicus, and Cochrane. A direct head-to-head comparator analysis and network meta-analysis were performed using the random-effects model. The odds ratio (OR) was calculated with a 95% confidence interval (CI) and p-value < 0.05 was considered statistically significant. RESULTS: We analyzed 26 studies, involving 22,560 subjects. In the direct comparative analysis, AI demonstrated higher ADR (OR: 0.668, 95% CI 0.595-0.749, p < 0.001) than single observer. Dual observer demonstrated a higher ADR (OR: 0.771, 95% CI 0.688-0.865, p < 0.001) than single operator. In network meta-analysis, results were consistent on the network meta-analysis, maintaining consistency. No statistical difference was noted when comparing AI to second observer. (RR 1.1 (0.9-1.2, p = 0.3). Results were consistent when evaluating only RCTs. Net ranking provided higher score to AI followed by second observer followed by single observer. CONCLUSION: Artificial Intelligence and second-observer colonoscopy showed superior success in Adenoma Detection Rate when compared to single-observer colonoscopy. Although not statistically significant, net ranking model favors the superiority of AI to the second observer.


Assuntos
Adenoma , Neoplasias Colorretais , Humanos , Inteligência Artificial , Colonoscopia/métodos , Adenoma/diagnóstico , Metanálise em Rede , Razão de Chances , Neoplasias Colorretais/diagnóstico
10.
Dig Endosc ; 36(1): 40-48, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37079002

RESUMO

OBJECTIVE: This study was performed to evaluate whether the use of CAD EYE (Fujifilm, Tokyo, Japan) for colonoscopy improves colonoscopy quality in gastroenterology trainees. METHODS: The patients in this multicenter randomized controlled trial were divided into Group A (observation using CAD EYE) and Group B (standard observation). Six trainees performed colonoscopies using a back-to-back method in pairs with gastroenterology experts. The primary end-point was the trainees' adenoma detection rate (ADR), and the secondary end-points were the trainees' adenoma miss rate (AMR) and Assessment of Competency in Endoscopy (ACE) tool scores. Each trainee's learning curve was evaluated using a cumulative sum (CUSUM) control chart. RESULTS: We analyzed data for 231 patients (Group A, n = 113; Group B, n = 118). The ADR was not significantly different between the two groups. Group A had a significantly lower AMR (25.6% vs. 38.6%, P = 0.033) and number of missed adenomas per patient (0.5 vs. 0.9, P = 0.004) than Group B. Group A also had significantly higher ACE tool scores for pathology identification (2.26 vs. 2.07, P = 0.030) and interpretation and identification of pathology location (2.18 vs. 2.00, P = 0.038). For the CUSUM learning curve, Group A showed a trend toward a lower number of cases of missed multiple adenomas by the six trainees. CONCLUSION: CAD EYE did not improve ADR but decreased the AMR and improved the ability to accurately locate and identify colorectal adenomas. CAD EYE can be assumed to be beneficial for improving colonoscopy quality in gastroenterology trainees. TRIAL REGISTRATION: University Hospital Medical Information Network Clinical Trials Registry (UMIN000044031).


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Inteligência Artificial , Estudos Prospectivos , Competência Clínica , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Adenoma/diagnóstico , Adenoma/patologia , Pólipos do Colo/diagnóstico
11.
Clin Gastroenterol Hepatol ; 21(1): 200-209.e6, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35341951

RESUMO

BACKGROUND & AIMS: The proportion of colonoscopies with at least one adenoma (adenoma detection rate [ADR]) is inversely associated with colorectal cancer (CRC) risk and death. The aim of this study was to examine whether such associations exist for colonoscopy quality measures other than ADR. METHODS: We used data from the Polish Colorectal Cancer Screening Program collected in 2000-2011. For all endoscopists who performed ≥100 colonoscopies we calculated detection rates of adenomas (ADR), polyps (PDR), and advanced adenomas (≥10 mm/villous component/high-grade dysplasia [AADR]); and number of adenomas per colonoscopy (APC) and per colonoscopy with ≥1 adenoma (APPC). We followed patients until CRC diagnosed before recommended surveillance, death, or December 31, 2019. We estimated hazard ratios (HRs) and 95% confidence intervals (CIs) using Cox proportional-hazard models. We used Harrell's C statistic to compare the predictive power of the quality measures. RESULTS: Data on 173,287 patients (median age, 56 years; 37.8% male) and 262 endoscopists were used. During a median follow-up of 10 years and 1,490,683 person-years, we identified 395 CRCs. All quality measures were significantly associated with CRC risk and death. The relative reductions in CRC risk were as follows: for ADR ≥24.9% (reference <12.1%; HR, 0.41; 95% CI, 0.25-0.66), PDR ≥42.7% (reference <19.9%; HR, 0.35; 95% CI, 0.24-0.51), AADR ≥9.1% (reference <4.1%; HR, 0.69; 95% CI, 0.49-0.96), APC ≥0.37 (reference <0.15; HR, 0.35; 95% CI, 0.21-0.58), and APPC ≥1.54 (reference <1.19; HR, 0.54; 95% CI, 0.35-0.83). AADR was the only quality measure with significantly lower predictive power than ADR (Harrell's C, 59.7 vs 63.4; P = .001). Similar relative reductions were observed for CRC death. CONCLUSIONS: This large observational study confirmed the inverse association between ADR and CRC risk and death. The PDR and APC quality measures appear to be comparable with ADR.


Assuntos
Adenoma , Neoplasias Colorretais , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Indicadores de Qualidade em Assistência à Saúde , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Colonoscopia , Risco , Programas de Rastreamento , Adenoma/diagnóstico , Detecção Precoce de Câncer
12.
Clin Gastroenterol Hepatol ; 21(6): 1493-1502.e4, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36328306

RESUMO

BACKGROUND & AIMS: Effects of linked-color imaging (LCI) on colorectal lesion detection and colonoscopy quality remain controversial. This study compared the detection rates of adenoma and other precursor lesions using LCI vs white-light imaging (WLI) during screening, diagnostic, and surveillance colonoscopies. METHODS: This randomized controlled trial was performed at 11 institutions in 4 Asian countries/regions. Patients with abdominal symptoms, a primary screening colonoscopy, positive fecal immunochemical test results, or undergoing postpolypectomy surveillance were recruited and randomly assigned in a 1:1 ratio to either the LCI or high-definition WLI group. The primary outcome was adenoma detection rate (ADR). Secondary outcomes were polyp detection rate, advanced ADR, sessile serrated lesion (SSL) detection rate, and the mean number of adenomas per colonoscopy. The recommended surveillance schedule distribution after trial colonoscopy was analyzed. RESULTS: Between November 2020 and January 2022, there were 3050 participants (LCI, n = 1527; WLI, n = 1523) recruited. The LCI group ADR was significantly higher than the WLI group ADR using intention-to-treat (58.7% vs 46.7%; P < .01) and per-protocol analyses (59.6% vs 46.4%; P < .01). The LCI group polyp detection rates (68.6% vs 59.5%; P < .01), SSL detection rates (4.8% vs 2.8%; P < .01), and adenomas per colonoscopy (1.48 vs 1.02; P < .01) also were significantly higher. However, the advanced ADR was not significantly different (13.2% vs 11.0%; P = .06). Significantly more patients in the LCI group had shorter recommended surveillance schedules than the WLI group (P < .01). CONCLUSIONS: Compared with WLI, LCI improved adenoma and other polyp detection rates, including SSLs, resulting in alteration of the recommended surveillance schedule after screening, diagnostic, and postpolypectomy surveillance colonoscopies. TRIAL REGISTRATION NUMBER: UMIN000042432 (https://www.umin.ac.jp/ctr/index.htm).


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Pólipos , Humanos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Colonoscopia/métodos , Adenoma/diagnóstico , Adenoma/patologia , Pólipos/diagnóstico , Diagnóstico por Imagem , Pólipos do Colo/diagnóstico
13.
Clin Gastroenterol Hepatol ; 21(13): 3238-3257, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37080261

RESUMO

BACKGROUND & AIMS: Adenoma detection rate (ADR) is inversely correlated with the risk of interval colon cancer and is a key target for quality improvement in endoscopy units. We conducted a systematic review and meta-analysis to identify and evaluate the effectiveness of interventions that can be implemented at the endoscopy unit level to improve ADRs. METHODS: Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, a systematic search was conducted in MEDLINE, Embase, and Cochrane Central Register of Controlled Trials databases between January 1990 and December 2022 to identify relevant studies. Both randomized controlled trials and observational studies were eligible. Data for the primary outcome of ADR were analyzed and reported on the log-odds scale with 95% CIs using a random-effects meta-analysis model using the empiric Bayes estimator. RESULTS: From 10,778 initial citations, 34 studies were included in the meta-analysis comprising 371,041 procedures and 1501 endoscopists. The provision of report cards (odds ratio [OR], 1.28; 95% CI, 1.13-1.45; P < .001) and the presence of an additional observer to identify polyps (OR, 1.25; 95% CI, 1.09-1.43; P = .002) were associated with significant increases in ADRs whereas multimodal interventions were borderline significant (OR, 1.18; 95% CI, 1.00-1.40; P = .05) and withdrawal time monitoring was not associated significantly with an increase in ADRs (OR, 1.35; 95% CI, 0.93-1.96; P = .11). CONCLUSIONS: The provision of report cards and the presence of an additional observer to identify polyps are associated with improved ADRs and should be considered for implementation in endoscopy facilities.


Assuntos
Adenoma , Neoplasias do Colo , Pólipos , Humanos , Colonoscopia/métodos , Teorema de Bayes , Adenoma/diagnóstico , Melhoria de Qualidade
14.
Cancer Control ; 30: 10732748231193243, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37528552

RESUMO

BACKGROUND: Although colonoscopy is considered the most effective tool for reducing colorectal cancer-related morbidity, the age at which average-risk individuals begin colonoscopic screening is undetermined. This study aimed to compare the adenoma and advanced adenoma detection rates according to age and sex in a large average-risk population in the rural areas of Eastern China. METHODS: This observational, single-center, retrospective study included patients with average colorectal cancer risk and examined the adenoma and advanced adenoma detection rates using age intervals of 5 years. We also compared the size and age of patients with and without advanced adenoma. RESULTS: We included 18 928 patients with a median age of 54 years (range 15-90 years), including 10 143 men and 8785 women. The adenoma and advanced adenoma detection rates were 17.08% and 5.24%, respectively, and increased with age in the whole population. The adenoma detection rates increased from 8.97% (aged 40-44) to 14.98% (aged 45-49) and 6.24% (aged 45-49) to 11.00% (aged 50-54) in men and women (both P < .001), respectively. The advanced adenoma detection rates increased from 2.19% (aged 40-44) to 4.76% (aged 45-49) and 1.89% (aged 45-49) to 3.13% (aged 50-54) in men (P = .002) and women (P = .056), respectively. Patients with advanced adenomas were significantly older than those with non-advanced adenomas (P < .001). The tumors in the advanced adenoma group were significantly larger than those in the non-advanced adenoma group (P < .001). CONCLUSION: The adenoma and advanced adenoma detection rates increased significantly in average-risk population aged 45 years and older, especially in men.


Assuntos
Adenoma , Neoplasias Colorretais , Masculino , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Neoplasias Colorretais/patologia , Fatores de Risco , Colonoscopia , Adenoma/diagnóstico , Adenoma/epidemiologia , Detecção Precoce de Câncer
15.
Scand J Gastroenterol ; 58(8): 937-944, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36756743

RESUMO

INTRODUCTION: Overall caecum intubation rate(oCIR) and overall polyp detection rate(oPDR) have been proposed as performance indicators, but varying complexity in case mix among endoscopists may potentially affect validity. The study aims to explore the effect of adjusting for case mix on individual endoscopist performance by calculating case mix-adjusted performance estimates (cmCIR and cmPDR) and comparing them to overall performance estimates (oCIR and oPDR). The study also provides an R program for case mix analysis. METHODS: Logistic regression associated endoscopist, colonoscopy indication, patient age and patient gender with the binary outcomes of cecum intubation and polyp detection. Case mix-adjusted performance indicators were calculated for each endoscopist based on logistic regression and bootstraps. Endoscopists were ranked from best to worst by overall and case mix-adjusted performance estimates, and differences were evaluated using percentage points(pp) and rank changes. RESULTS: The dataset consisted of 7376 colonoscopies performed by 47 endoscopists. The maximum rank change for an endoscopist comparing oCIR and cmCIR was eight positions, interquartile range (IQR 1-3). The maximum change in CIR was 1.95 percentage point (pp) (IQR 0.27-0.86). The maximum rank change in the oPDR versus cmPDR analysis was 17 positions (IQR 1.5-8.5). The maximum change in PDR was 11.21 pp (IQR 2.05-6.70). Three endoscopists improved their performance from significantly inferior to within the 95% confidence interval (CI) range of performance targets using case mix-adjusted estimates. CONCLUSIONS: The majority of endoscopists were unaffected by adjustment for case mix, but a few unfortunate endoscopists had an unfavourable case mix that could invite incorrect suspicion of inferior performance.


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Humanos , Pólipos do Colo/diagnóstico , Colonoscopia , Ceco , Modelos Logísticos , Grupos Diagnósticos Relacionados , Neoplasias Colorretais/diagnóstico
16.
BMC Gastroenterol ; 23(1): 347, 2023 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-37803276

RESUMO

BACKGROUND: Surveillance colonoscopy decreases colorectal cancer mortality; however, lesions are occasionally missed. Although an appropriate surveillance interval is indicated, variations may occur in the methods used, such as scope manipulation or observation. Therefore, individual endoscopists may miss certain areas. This study aimed to verify the effectiveness of performing repeat colonoscopies with a different endoscopist from the initial procedure. METHODS: We retrospectively reviewed a database of 8093 consecutive colonoscopies performed in the Omori Red Cross Hospital from January 1st 2018 to June 30th 2021. Data from repeat total colonoscopies performed within three months were collected to assess missed lesions. The patients were divided into two groups according to whether the two examinations were performed by different endoscopists (group D) or the same endoscopist (group S). The primary outcome in both groups was the missed lesion detection rate (MLDR). RESULTS: Overall, 205 eligible patients were analyzed. In total, 102 and 103 patients were enrolled in groups D and S, respectively. The MLDR was significantly higher in group D (61.8% vs. 31.1%, P < 0.0001). Multivariate logistic regression analysis for the detection of missed lesions identified performance by the different endoscopists (odds ratio, 3.38; 95% CI, 1.81-6.30), and sufficient withdrawal time (> 6 min) (odds ratio, 3.10; 95% CI, 1.12-8.61) as significant variables. CONCLUSIONS: Overall, our study showed a significant improvement in the detection of missed lesions when performed by different endoscopists. When performing repeat colonoscopy, it is desirable that a different endoscopist perform the second colonoscopy. TRIAL REGISTRATION: This study was approved by the Institutional Review Board of the Omori Red Cross Hospital on November 28, 2022 (approval number:22-43).


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Estudos Retrospectivos , Pólipos do Colo/patologia , Colonoscopia/métodos , Razão de Chances , Adenoma/diagnóstico , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia
17.
Int J Colorectal Dis ; 38(1): 63, 2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36884096

RESUMO

BACKGROUND: Melanosis coli is characterized by brown mucosa with pigmentation. Studies have showed an increased adenoma detection rate in melanosis patients, whether it is caused by a contrast effect or an oncogenic effect is still controversial. The detection of serrated polys in melanosis patients remains unknown. AIMS: The study aimed to clarify the correlation of adenoma detection rate with melanosis coli and discuss outcomes in less-experienced endoscopists. Serrated polyp detection rate was also been investigated. METHODS: A total of 2150 patients and 39,630 controls were enrolled. A propensity score matching method was used to balance covariates between the two groups. The detection of polyps, adenomas, serrated polyps, and their features was analyzed. RESULTS: The polyp detection rate (44.65% vs 41.01%, P = 0.005) and adenoma detection rate (30.34% vs 23.92%, P < 0.001) were significantly higher, and the serrated polyp detection rate (0.93% vs 1.58%, P = 0.033) was significantly lower in melanosis coli. The percentage of low-risk adenomas (44.60% vs 39.16%, P < 0.001) and polyps with 6 to 10 mm in size (20.16% vs 16.21%, P < 0.001) were higher in melanosis coli. The detection of large serrated polyps was lower (0.11% vs 0.41%, P = 0.026) in melanosis coli. CONCLUSION: Melanosis coli correlates with an increased adenoma detection rate. The detection of large serrated polyps was lower in melanosis patients. Melanosis coli may not be considered a precancerous lesion.


Assuntos
Adenoma , Doenças do Colo , Pólipos do Colo , Neoplasias Colorretais , Melanose , Humanos , Pólipos do Colo/diagnóstico , Pólipos do Colo/patologia , Colonoscopia , Estudos Retrospectivos , Neoplasias Colorretais/patologia , Melanose/diagnóstico , Adenoma/diagnóstico , Adenoma/patologia
18.
Int J Colorectal Dis ; 38(1): 240, 2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37755588

RESUMO

INTRODUCTION: The incremental yield of I-Scan virtual chromoendoscopy compared to high-definition white light endoscopy (HD-WLE) in detection of colorectal adenomas has not been thoroughly elucidated. METHODS: A systematic search from inception to April 2023 was conducted to identify randomized controlled trials (RCTs) comparing I-Scan to HD-WLE for detection of adenomas. A random effects model was used to compute risk difference (RD) with corresponding 95% confidence intervals in adenoma detection rate (ADR). Influence analysis was done to assess robustness of findings. The number needed to diagnose was computed. Heterogeneity was assessed using the I2 statistic and explored further by subgroup analyses defined a priori. Certainty in effect estimates was assessed using the GRADE approach. RESULTS: We identified four studies (I-Scan n = 730, HD-WLE n = 765). I-Scan increased adenoma detection by 9% (risk difference (RD), 0.09; 0.04, 0.14; I2 02%; certainty, low). Influence analysis revealed that the gain in yield remained statistically significant with exclusion of all but one study. The number needed to capture one additional adenomatous polyp with I-Scan use was 11.2. I-Scan 1 use was associated with a statistically significant gain in ADR, whereas no significant difference in ADR was noted with I-Scan use on subgroup analysis. DISCUSSION: In conclusion, I-Scan increases the yield of adenoma detection by 9% compared to HD-WLE, with low certainty in the estimate of this effect. Data on the gain in yield of detecting large polyps, sessile serrated lesions, and on the impact of formally training endoscopists and trainees in I-Scan use and similar technology on adenoma detection rate are needed.


Assuntos
Adenoma , Neoplasias Colorretais , Pólipos , Humanos , Colonoscopia , Adenoma/diagnóstico por imagem , Neoplasias Colorretais/diagnóstico , Luz
19.
J Gastroenterol Hepatol ; 38(2): 162-176, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36350048

RESUMO

BACKGROUND AND AIM: Multiple computer-aided techniques utilizing artificial intelligence (AI) have been created to improve the detection of polyps during colonoscopy and thereby reduce the incidence of colorectal cancer. While adenoma detection rates (ADR) and polyp detection rates (PDR) are important colonoscopy quality indicators, adenoma miss rates (AMR) may better quantify missed lesions, which can ultimately lead to interval colorectal cancer. The purpose of this systematic review and meta-analysis was to determine the efficacy of computer-aided colonoscopy (CAC) with respect to AMR, ADR, and PDR in randomized controlled trials. METHODS: A comprehensive, systematic literature search was performed across multiple databases in September of 2022 to identify randomized, controlled trials that compared CAC with traditional colonoscopy. Primary outcomes were AMR, ADR, and PDR. RESULTS: Fourteen studies totaling 10 928 patients were included in the final analysis. There was a 65% reduction in the adenoma miss rate with CAC (OR, 0.35; 95% CI, 0.25-0.49, P < 0.001, I2  = 50%). There was a 78% reduction in the sessile serrated lesion miss rate with CAC (OR, 0.22; 95% CI, 0.08-0.65, P < 0.01, I2  = 0%). There was a 52% increase in ADR in the CAC group compared with the control group (OR, 1.52; 95% CI, 1.39-1.67, P = 0.04, I2  = 47%). There was 93% increase in the number of adenomas > 10 mm detected per colonoscopy with CAC (OR 1.93; 95% CI, 1.18-3.16, P < 0.01, I2  = 0%). CONCLUSIONS: The results of the present study demonstrate the promise of CAC in improving AMR, ADR, PDR across a spectrum of size and morphological lesion characteristics.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Pólipos do Colo/patologia , Inteligência Artificial , Colonoscopia/métodos , Adenoma/diagnóstico , Computadores , Neoplasias Colorretais/patologia
20.
Digestion ; 104(3): 193-201, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36599306

RESUMO

INTRODUCTION: Computer-aided diagnostic systems are emerging in the field of gastrointestinal endoscopy. In this study, we assessed the clinical performance of the computer-aided detection (CADe) of colonic adenomas using a new endoscopic artificial intelligence system. METHODS: This was a single-center prospective randomized study including 415 participants allocated into the CADe group (n = 207) and control group (n = 208). All endoscopic examinations were performed by experienced endoscopists. The performance of the CADe was assessed based on the adenoma detection rate (ADR). Additionally, we compared the adenoma miss rate for the rectosigmoid colon (AMRrs) between the groups. RESULTS: The basic demographic and procedural characteristics of the CADe and control groups were as follows: mean age, 54.9 and 55.9 years; male sex, 73.9% and 69.7% of participants; and mean withdrawal time, 411.8 and 399.0 s, respectively. The ADR was 59.4% in the CADe group and 47.6% in the control group (p = 0.018). The AMRrs was 11.9% in the CADe group and 26.0% in the control group (p = 0.037). CONCLUSION: The colonoscopy with the CADe system yielded an 11.8% higher ADR than that performed by experienced endoscopists alone. Moreover, there was no need to extend the examination time or request the assistance of additional medical staff to achieve this improved effectiveness. We believe that the novel CADe system can lead to considerable advances in colorectal cancer diagnosis.


Assuntos
Adenoma , Neoplasias do Colo , Pólipos do Colo , Neoplasias Colorretais , Humanos , Masculino , Pessoa de Meia-Idade , Inteligência Artificial , Pólipos do Colo/diagnóstico por imagem , Estudos Prospectivos , Colonoscopia , Adenoma/diagnóstico por imagem , Computadores , Neoplasias Colorretais/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA