1.
Skeletal Radiol ; 53(11): 2511-2517, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38236295

RESUMO

Metallosis is an unusual but consequential complication arising from orthopedic hardware implantation, characterized by the deposition of metallic particles in the periprosthetic soft tissues. The incidence of metallosis associated with shoulder arthroplasties is exceptionally rare since the shoulder is not a weight-bearing joint, making it less susceptible to mechanical wear and, consequently, to conditions like particle disease and metallosis. Nevertheless, anomalous metal-on-metal interactions can develop in total shoulder arthroplasties if the polyethylene component fails due to wear, fracture, or dissociation. If left unaddressed, metallosis can incite an adverse immune-mediated local tissue response, culminating in joint destruction and adjacent soft tissues and muscle necrosis. In this case report, the diagnosis of metallosis was made in a patient with an anatomic total shoulder arthroplasty using a state-of-the-art photon counting detector CT supplemented by post-processing metal artifact reduction algorithms. This advanced imaging approach was effective in discerning the source of implant failure and in identifying manifestations of severe metallosis including osteolysis and pseudotumor formation. Advanced imaging methods can accurately characterize the severity and extent of metallosis, thereby helping guide surgical planning to mitigate serious complications associated with this condition.


Assuntos
Artroplastia do Ombro , Falha de Prótese , Humanos , Artroplastia do Ombro/efeitos adversos , Prótese de Ombro/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Metais/efeitos adversos , Masculino , Idoso , Feminino , Reoperação
2.
J Arthroplasty ; 39(9): 2368-2376, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38640966

RESUMO

BACKGROUND: Modular dual mobility (DM) bearings have a junction between a cobalt chrome alloy (CoCrMo) liner and titanium shell, and the risk of tribocorrosion at this interface remains a concern. The purpose of this study was to determine whether liner malseating and liner designs are associated with taper tribocorrosion. METHODS: We evaluated 28 retrieved modular DM implants with a mean in situ duration of 14.6 months (range, 1 to 83). There were 2 manufacturers included (12 and 16 liners, respectively). Liners were considered malseated if a distinct divergence between the liner and shell was present on postoperative radiographs. Tribocorrosion was analyzed qualitatively with the modified Goldberg Score and quantitatively with an optical coordinate-measuring machine. An acetabular shell per manufacturer was sectioned for metallographic analysis. RESULTS: There were 6 implants (22%) that had severe grade 4 corrosion, 6 (22%) had moderate grade 3, 11 (41%) had mild grade 2, and 5 (18.5%) had grade 1 or no visible corrosion. The average volumetric material loss at the taper was 0.086 ± 0.19 mm3. There were 7 liners (25%) that had radiographic evidence of malseating, and all were of a single design (P = .01). The 2 liner designs were fundamentally different from one another with respect to the cobalt chrome alloy type, taper surface finish, and shape deviations. Malseating was an independent risk factor for increased volumetric material loss (P = .017). CONCLUSIONS: DM tribocorrosion with quantifiable material loss occurred more commonly in malseated liners. Specific design characteristics may make liners more prone to malseating, and the interplay between seating mechanics, liner characteristics, and patient factors likely contributes to the shell/liner tribocorrosion environment. LEVEL OF EVIDENCE: Level III.


Assuntos
Artroplastia de Quadril , Ligas de Cromo , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Humanos , Corrosão , Artroplastia de Quadril/instrumentação , Idoso , Pessoa de Meia-Idade , Feminino , Masculino , Idoso de 80 Anos ou mais , Titânio , Adulto , Estudos Retrospectivos
3.
J Arthroplasty ; 39(9S1): S183-S187, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38336305

RESUMO

BACKGROUND: Ceramic heads are frequently combined with titanium sleeves in revision total hip arthroplasties (THAs), ostensibly to protect the ceramic head from existing damage to the retained trunnion. Although widely adopted, data on the performance and safety of this construct are minimal. The purpose of this study was to describe implant survivorships, radiographic results, and clinical outcomes of patients who underwent revision THA with a ceramic head and titanium sleeve on a retained femoral component. METHODS: We identified 516 revision THAs with femoral component retention (328 acetabular-only revisions and 188 bearing surface exchanges) treated with a new ceramic head and titanium sleeve between 2000 and 2020. Mean age at revision was 64 years, 56% were women, and mean body mass index was 30. The indications for revision THA were adverse local tissue reaction (25%), acetabular loosening (24%), dislocation (17%), infection (5%), and other (29%). Kaplan-Meier survivorships were analyzed, radiographs reviewed, and Harris Hip Scores evaluated. Mean follow-up was 4 years (range, 2 to 10). RESULTS: There were no reoperations or failures for ceramic head fracture, taper corrosion, or head/sleeve disengagement. The 10-year survivorship free of any re-revision was 85%. Indications for the 57 re-revisions included dislocation (33), infection (13), acetabular component loosening (7), periprosthetic fracture (2), psoas impingement (1), and sciatic nerve irritation (1). The 10-year survivorship free of any reoperation was 82%. There were an additional 14 reoperations. Radiographically, 1.9% had progressive femoral radiolucent lines, and 4.7% had progressive acetabular radiolucent lines. Mean Harris Hip Score was 81 at 2 years. CONCLUSIONS: New ceramic heads with titanium sleeves in revision THAs with retained femoral components were durable and reliable with no cases of ceramic head fracture or taper complications at mean 4-year follow-up, including those revised for adverse local tissue reaction. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia de Quadril , Cerâmica , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Reoperação , Titânio , Humanos , Reoperação/estatística & dados numéricos , Feminino , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/efeitos adversos , Pessoa de Meia-Idade , Prótese de Quadril/efeitos adversos , Masculino , Idoso , Adulto , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Resultado do Tratamento , Articulação do Quadril/cirurgia , Articulação do Quadril/diagnóstico por imagem
4.
Arch Orthop Trauma Surg ; 143(6): 3649-3657, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36178493

RESUMO

INTRODUCTION: Breakage of exchangeable-neck (EN) and adverse local tissue reactions (ALTRs) to neck-stem junction (NSJ) damage products are responsible for increasing the revision rate of EN hip prostheses. We investigated the survivorship of an EN hip prosthesis including a NSJ with both components made of titanium alloy (Ti-alloy/Ti-alloy) to assess whether, and to what extent, EN breakage and NSJ damage affected implant survivorship. MATERIALS AND METHODS: Using data from a hip replacement registry, we determined survivorship of 2857 EN prostheses. Long-offset configurations of head and EN were implanted in heavy (> 90 kg) patients only in 23 hips. We investigated under which conditions EN breakages or ALTRs occurred. We also measured titanium (Ti) and vanadium (V) blood concentrations in 24 patients with a unilateral well-working prosthesis. RESULTS: The 17-year survival rates for any reason and aseptic loosening of any component were 88.9% (95%CI 87.5-90.1; 857 hips at risk) and 96.9% (95%CI 96.0-97.6), respectively. There were two cases of EN breakage and one case of ALTR (metallosis), due to rim-neck impingement, out of 276 revisions. After an average period of 9.8 years (range 7.8-12.8 years), the maximum Ti and V blood concentrations in patients with a well-working prosthesis were 5.0 µg/l and 0.16 µg/l, respectively. CONCLUSION: The present incidence of EN breakage or ALTR is lower than those reported in other studies evaluating EN hip prosthesis survivorship. This study suggests that (i) the risk of EN breakage is reduced by limiting the use of long-offset configurations in heavy patients and (ii) Ti-alloy/Ti-alloy NSJ damage products do not promote ALTR nor significantly alter the rate of implant loosening. Since design decisions and implant configuration determine the NSJ strength, the NSJ strength in working conditions must be thoroughly investigated to proper define the clinical indications for any EN design.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Prótese de Quadril/efeitos adversos , Ligas , Titânio , Sobrevivência , Desenho de Prótese , Artroplastia de Quadril/efeitos adversos , Falha de Prótese , Reoperação/efeitos adversos
5.
J Arthroplasty ; 37(12): 2406-2411, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35738363

RESUMO

BACKGROUND: Revision total hip arthroplasty (THA) for adverse local tissue reactions (ALTRs) secondary to head-neck taper corrosion is associated with a high complication rate. Diagnosis of ALTR is based on risk stratification using the patient's history and examination, implant risk, serum metal ion levels, and imaging. The purpose of this study was to determine if stratification using similar risk factors is predictive of outcomes following revision THA for metal-on-polyethylene (MoP) ALTR. METHODS: We performed a retrospective review on 141 patients revised for ALTR due to head-neck taper corrosion. Pain outcomes following surgery were analyzed using a generalized linear mixed model. Complications were defined as instability/dislocation, infection, fracture, nerve palsy, leg-length discrepancy, or reoperation. RESULTS: The overall complication rate was 17.7%. The odds of having pain decreased by 44% after revision surgery (Odds Ratio = 0.56, 95% Confidence Interval: 0.324 to 0.952). There was no significant difference in instability/dislocation based on either increased or decreased head-neck offset (P = .67) or magnetic resonance imaging findings of abductor loss, effusion size, and degree of ALTR (P = .73). Increased serum cobalt (P = .31) and chromium (P = .08) levels did not predict complications; however, a decreased cobalt-chromium ratio was associated with postoperative complications (2.8 versus 3.5; P = .002). CONCLUSION: These findings are the first to suggest that patients who have ALTR after MoP THA undergoing revision surgery demonstrated major pain relief. Increasing femoral head offset did not change rates of instability/dislocation. In clinical scenarios where preoperative cobalt-chromium femoral head offsets were greater than available ceramic head offsets, a mandatory decrease in femoral head offset did not increase rates of instability/dislocation.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Reoperação/efeitos adversos , Prótese de Quadril/efeitos adversos , Falha de Prótese , Desenho de Prótese , Polietileno , Cobalto , Cromo , Corrosão , Metais , Medição de Risco , Dor/etiologia
6.
J Arthroplasty ; 37(8S): S941-S946, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34822931

RESUMO

BACKGROUND: One percent to 3% of contemporary non-cemented total hip arthroplasties (THAs) present with symptomatic mechanically assisted crevice corrosion (MACC). The incidence of this problem, however, as well as the rate of asymptomatic elevations in serum cobalt, is unknown. METHODS: Cobalt and chromium levels were obtained in conjunction with radiographs at routine 10-year surveillance follow-up of THAs from a single manufacturer with a titanium stem, cobalt alloy femoral head, and cross-linked polyethylene countersurface. RESULTS: Ten-year follow-up of patients with 162 consecutive THAs revealed that 17 patients with 18 hips had died of unrelated causes prior to metal ion testing. Two hips were revised for other reasons, and of the remaining 142 hips, 33 were in patients who were lost, leaving 109 hips (77% of those in alive patients and unrevised for other reasons and 67% of the entire cohort) for investigation. Sixty-three patients (58%) had a serum cobalt less than 1 ppb, and 35 (32%) a cobalt of ≥1 ppb, a cutoff consistent with MACC. Of the 32 hips with definite MACC, 15 of 32 (47%) patients were symptomatic, 16 of 30 (53%) patients had adverse local tissue reaction on magnetic resonance imaging, and 19 of 32 (59%) patients have undergone revision surgery for MACC to date. CONCLUSION: At 10-year follow-up, a minimum of 22% (35/162) of hips had a cobalt level more than 1 ppb, consistent with MACC. Symptoms and adverse local tissue reactions are each present about one-half of the time, and 59% of those with documented MACC have undergone revision.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Corrosão , Prótese de Quadril/efeitos adversos , Humanos , Incidência , Desenho de Prótese , Falha de Prótese , Reoperação/efeitos adversos
7.
Arch Orthop Trauma Surg ; 142(10): 2577-2583, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33837474

RESUMO

INTRODUCTION: Recalls of total hip arthroplasty (THA) implants, including metal-on-metal (MoM) THA and dual taper stems, due to increased risk of adverse local tissue reaction (ALTR), represent a challenge for both surgeons and patients. This study aims to analyze the revision surgery outcomes for ALTR in patients with recalled THA implants. METHODS: A total of 118 consecutive patients who underwent revision surgery due to ALTR with recalled THA were analyzed. Sub-group analysis was performed for recalled MoM THAs, head-neck modular stems, and dual taper neck-stems. RESULTS: At a mean follow-up of 6.6 years, the complication and reoperation rates of the recalled THAs were 32.2% and 25.4% respectively. The most common post-revision complication was dislocation (16%). Revision of modular taper corrosion THA and high-grade intraoperative tissue damage were risk factors associated with post-revision complications. CONCLUSION: This study reports high complication and reoperation rates of recalled THAs at mid-term follow-up. The high revision surgery complication rates in both groups suggest the importance of a systematic evaluation of all THA patients with at-risk implants. LEVEL OF EVIDENCE: Level III, case control retrospective analysis.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Prótese de Quadril/efeitos adversos , Humanos , Próteses Articulares Metal-Metal/efeitos adversos , Metais , Desenho de Prótese , Falha de Prótese , Reoperação/efeitos adversos , Estudos Retrospectivos
8.
J Arthroplasty ; 36(7S): S358-S362, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33036841

RESUMO

BACKGROUND: Diagnosis of adverse local tissue reaction (ALTR) in metal-on-polyethylene (MoP) total hip arthroplasty (THA) secondary to head-neck taper corrosion is challenging. The purpose of this study is to compare differences between asymptomatic and symptomatic ALTR in an observational cohort, including presentation, metal ion differences, and metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) findings. METHODS: We performed a retrospective review of an observational cohort of 492 MoP THA patients at increased risk of developing ALTR. Ninety-four patients underwent revision arthroplasty for ALTR. Patients were stratified into symptomatic and asymptomatic ALTR groups. Presentation, metal ion levels, and imaging findings were compared. RESULTS: For patients with confirmed ALTR, 41% were asymptomatic. There was a statistically significant difference in the serum chromium levels between symptomatic and asymptomatic ALTR patients (2.2 µg/L vs 3.1 µg/L, P = .05). There was no statistically significant difference between the serum cobalt levels or MRI findings in these 2 groups. We observed that extracapsular disease associated with ALTR could be misinterpreted as trochanteric bursitis. CONCLUSION: Almost half of the MoP THA ALTR cases identified were asymptomatic. Cobalt levels could not differentiate between symptomatic and asymptomatic pseudotumor formation. Symptomatic and asymptomatic MoP ALTRs have similar MARS MRI characteristics. Our findings suggest that it is essential to risk stratify patients who could potentially have ALTR based on implant type, symptoms, ion levels, and MARS MRI.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto/efeitos adversos , Corrosão , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
9.
Genomics ; 111(6): 1404-1411, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-30248488

RESUMO

Total hip arthroplasty (THA) alleviates hip pain and improves joint function. Current implant design permits long-term survivorship of THAs, but certain metal-on-metal (MoM) articulations can portend catastrophic failure due to adverse local tissue reactions (ALTR). Here, we identified biological and molecular differences between periacetabular synovial tissues of patients with MoM THA failure undergoing revision THA compared to patients undergoing primary THA for routine osteoarthritis (OA). Analysis of tissue biopsies by RNA-sequencing (RNA-seq) revealed that MoM patient samples exhibit significantly increased expression of immune response genes but decreased expression of genes related to extracellular matrix (ECM) remodeling. Thus, interplay between local tissue inflammation and ECM degradation may account for the pathology and compromised clinical outcomes in select patients with MoM implants. We conclude that adverse responses of host tissues to implant materials result in transcriptomic modifications in patients with MoM implants that permit consideration of strategies that could mitigate ECM damage.


Assuntos
Artroplastia de Quadril/efeitos adversos , Reação a Corpo Estranho/patologia , Próteses Articulares Metal-Metal/efeitos adversos , Osteoartrite/cirurgia , Falha de Prótese/etiologia , Sinoviócitos/patologia , Transcriptoma , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Reação a Corpo Estranho/etiologia , Reação a Corpo Estranho/metabolismo , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/patologia , Patologia Molecular , Reoperação , Sinoviócitos/metabolismo
10.
J Arthroplasty ; 35(12): 3686-3691, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32654942

RESUMO

BACKGROUND: Treatment of adverse local tissue reaction (ALTR) is challenging owing to high complications and poor outcomes after a revision surgery. As dislocation is the most common cause of reoperation, it is often necessary to use advanced articulations such as dual mobility. This study aims to evaluate the outcome and complication rates after revision surgery with dual mobility constructs, compared to constrained and conventional articulations in the setting of significant abductor deficiency due to ALTR. METHODS: Out of a total of 338 revision total hip arthroplasties for ALTR, 234 patients with a significant tissue necrosis and abductor muscle insufficiency (grade 3) were evaluated. The complication rates after revisions were compared between 42 hips with dual mobility implants, 24 hips with constrained liners, 104 hips with large diameter heads (36-40 mm), and 64 hips with small diameter heads (≤32 mm). RESULTS: After an average of 4 years of follow-up (2.8-8.6), the dual mobility articulation had no dislocation, compared to 4.1% and 15.5% for constrained liner and conventional articulations, respectively (P < .001). Utilization of dual mobility and constrained liner cup also did not increase the risk of nondislocation complications, including periprosthetic joint infection and periprosthetic fracture (P = .18 and .52). CONCLUSIONS: This study demonstrates significantly lower dislocation rates for dual mobility when compared to conventional articulations and comparable to constrained liners in cases of severe abductor deficiency due to ALTR, suggesting that dual mobility implants are viable surgical treatment alternatives to constrained liners to minimize dislocation during revision total hip arthroplasty in the setting of significant abductor deficiency due to ALTR.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Luxação do Quadril/epidemiologia , Luxação do Quadril/etiologia , Luxação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
11.
J Arthroplasty ; 35(10): 2919-2925, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32475785

RESUMO

BACKGROUND: We compared the revision risk between metal-on-polyethylene (MOP) and ceramic-on-polyethylene (COP) total hip arthroplasty patients and evaluated temporal changes in short-term revision risks for MOP patients. METHODS: Primary MOP (n = 9480) and COP (n = 3620) total hip arthroplasties were evaluated from the Medicare data set (October 2005 to December 2015) for revision risk, with up to 10 years of follow-up using multivariate analysis. Temporal change in the short-term revision risk for MOP was evaluated (log-rank and Wilcoxon tests). RESULTS: Revision incidence was 3.8% for COP and 4.3% for MOP. MOP short-term revision risk did not change over time (P ≥ .844 at 1 year and .627 at 2 years). Dislocation was the most common reason for revision (MOP: 23.5%; COP: 24.8%). Overall adjusted revision risks were not different between MOP and COP up to 10 years of follow-up (P ≥ .181). CONCLUSIONS: Concerns with corrosion for metal heads do not appear to result in significantly elevated revision risk for MOP at up to 10 years. Corrosion does not appear as a primary reason for revision compared to other mechanisms.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Idoso , Artroplastia de Quadril/efeitos adversos , Cerâmica , Corrosão , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Medicare , Polietileno , Desenho de Prótese , Falha de Prótese , Reoperação , Fatores de Risco , Estados Unidos
12.
J Arthroplasty ; 35(6S): S60-S62, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32061479

RESUMO

BACKGROUND: Modern total hip arthroplasty has seen an unfortunate increase in proportional implant failures secondary to adverse local tissue reactions (ALTRs) secondary to wear of metal-on-metal (MoM) bearings and mechanically assisted crevice corrosion (MACC) related to corrosion at implant junctions and tapers. The purpose of this study is to describe the appropriate choice of metal ion testing and evaluation of those levels to identify failed total hip arthroplasty implants containing cobalt and chromium. METHODS: When presented with an arthroplasty of concern, the surgeon must determine what metal ion levels to obtain and then incorporate those levels into a treatment algorithm. Patients with painful hip arthroplasties are evaluated for chromium and cobalt by obtaining whole blood and synovial metal levels. RESULTS: Synovial fluid cobalt had the highest correlation with ALTR compared with the other tests, with a threshold of 19.75 ng/ml, with a specificity of 89%, if the cobalt-to-chromium ratio is greater than 1.4 ng/ml in a metal on polyethylene hip, with a sensitivity of 95%. CONCLUSION: The interpretation of whole blood metal ions is a key component of the algorithm in treating the symptomatic hip arthroplasty but is not to be used in a vacuum.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Prótese de Quadril/efeitos adversos , Humanos , Íons , Próteses Articulares Metal-Metal/efeitos adversos , Desenho de Prótese , Falha de Prótese , Reoperação
13.
J Arthroplasty ; 35(11): 3338-3342, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32622715

RESUMO

BACKGROUND: Metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) has been recommended as a cross-sectional imaging modality in clinical evaluation of adverse local tissue reactions (ALTRs) in metal-on-metal (MoM) patients and metal-on-polyethylene (MoP) patients with taper corrosion. The aim of the study was to compare MARS MRI characteristics of ALTR in MoM total hip arthroplasty (THA) with ALTR in MoP THA with modular taper corrosion. METHODS: A total of 197 patients with ALTR were evaluated: 86 patients with MoM THA; 37 MoP patients with head-neck taper corrosion; and 74 MoP patients with neck-stem dual taper corrosion. MARS MRI scans were evaluated to identify location, size, type of ALTR (I-III), and associated ALTR synovitis (cystic, solid, and mixed). RESULTS: MARS MRI characteristics of ALTR were significantly different between the MoM and MoP groups (P = .017). The MoP group demonstrated the highest proportion of thick-walled cystic masses type II (56.7% in head-neck taper corrosion MoP and 46.5% in dual taper corrosion MoP vs 28.7% in MoM), whereas the MoM group had the highest proportion of thin-walled cystic masses type I. MoM implants (96.8%) were significantly more likely to have ALTR in multiple locations compared with both MoP groups (P = .001). CONCLUSION: This study demonstrates that MARS MRI characteristics of ALTR differ by bearing type with a significantly higher percentage of mixed type and solid type ALTR in the taper corrosion MoP THA compared with MoM THA. This information provides clinically useful information in evaluation of symptomatic MoP and MoM THA patients for ALTRs.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Corrosão , Prótese de Quadril/efeitos adversos , Humanos , Imageamento por Ressonância Magnética , Polietileno , Desenho de Prótese , Falha de Prótese
14.
J Arthroplasty ; 35(6S): S284-S288, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32113811

RESUMO

BACKGROUND: Adverse local tissue reactions (ALTRs), initially described as a complication of metal-on-metal (MoM) total hip arthroplasty (THA), have also become an important risk factor for implant failure requiring revision surgery in metal-on-polyethylene (MoP) THA due to modular taper corrosion. This study aims to report early complication rates and outcomes as well as potential risk factors for a re-revision. METHODS: A total of 252 consecutive THA patients who underwent revision for ALTR were reviewed. There were 40 patients (16%) who underwent a second revision: (1) 26 MoP patients with modular taper corrosion and (2) 14 MoM patients. Patient demographics as well as clinical information were analyzed. Binary logistic regression was used to test for associations between re-revision surgery and clinical parameters. RESULTS: The overall complication rate following initial revision for ALTR was 21%. Sixteen percent of these revision patients required a re-revision. The most common indication for re-revision was dislocation (45%). The complication rate was 35% following a re-revision which included dislocation (36%), infection (36%), fracture (14%), and implant loosening (14%). The rate of patients requiring a third revision was 23% with the most common indications being dislocation (33%) and infection (33%) (P = .032). CONCLUSION: High rate of early complications (35%) and third revisions (23%) were observed following re-revision of symptomatic ALTR patients with those requiring re-revision associated with extensive intraoperative tissue necrosis. These findings provide clinically useful information that may assist surgeons in clinical decision making and preoperative counseling of both MoM and MoP patients undergoing re-revision surgery for ALTR.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Prótese de Quadril/efeitos adversos , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese , Reoperação , Resultado do Tratamento
15.
J Arthroplasty ; 35(12): 3737-3742, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32665158

RESUMO

BACKGROUND: The accurate diagnosis of periprosthetic joint infection (PJI) in the setting of adverse local tissue reactions in patients with metal-on-polyethylene (MoP) total hip arthroplasty (THA) secondary to head-neck taper junction corrosion is challenging as it frequently has the appearance of purulence. The aim of this study is to evaluate the utility of erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and synovial fluid markers in diagnosing PJI in failed MoP THA due to head-neck taper corrosion. METHODS: A total of 89 consecutive patients with MoP THA with head-neck taper corrosion in 2 groups was evaluated: (1) infection group (n = 11) and (2) noninfection group (n = 78). All patients had highly crossed polyethylene with cobalt chromium femoral heads and had preoperative synovial fluid aspiration. In addition, serum cobalt and chromium levels were analyzed. RESULTS: The optimal cutoff value for synovial white blood cell was 2144 with 93% sensitivity and 84% specificity. Neutrophil count optimal cutoff value was 82% with 93% sensitivity and 82% specificity. Receiver operating characteristic analysis of ESR and CRP determined optimal cutoff at 57 mm/h and 35 mg/L with 57% sensitivity and 94% specificity and 93% sensitivity and 76% specificity, respectively. There were no significant differences in metal ion levels between the infected and noninfected groups. CONCLUSION: The results of this study suggest that ESR and CRP are useful in excluding PJI, whereas both synovial white blood cell count and neutrophil percentage in hip aspirate are useful markers for diagnosing infection in MoP THA patients with head-neck taper corrosion associated adverse local tissue reaction.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Cobalto , Corrosão , Prótese de Quadril/efeitos adversos , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese , Reoperação , Líquido Sinovial
16.
J Arthroplasty ; 33(7S): S270-S274, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29428467

RESUMO

BACKGROUND: This study investigated the influence of femoral head impaction force, number of head strikes, the energy sequence of head strikes, and head offset on the strength of the taper-trunnion junction. METHODS: Thirty titanium-alloy trunnions were mated with 36-mm zero-offset cobalt-chromium femoral heads of corresponding taper angle. A drop tower impacted the head with 2.5J or 8.25J, resulting in 6 kN or 14 kN impaction force, respectively, in a single strike or combinations of 6 kN + 14 kN or 14 kN + 14 kN. In addition, ten 36-mm heads with -5 and +5 offset were impacted with sequential 14 kN + 14 kN strikes. Heads were subsequently disassembled using a screw-driven mechanical testing frame, and peak distraction force was recorded. RESULTS: Femoral head pull-off force was 45% the strike force, and heads struck with a single 14 kN impact showed a pull-off force twice that of the 6 kN group. Two head strikes with the same force did not improve pull-off force for either 6 kN (P = .90) or 14 kN (P = .90). If the forces of the 2 impactions varied, but either impact measured 14 kN, a 51% higher pull-off force was found compared to impactions of either 6 kN or 6 kN + 6 kN. Femoral head offset did not significantly change the pull-off force among -5, 0, and +5 heads (P = .37). CONCLUSION: Femoral head impaction force influenced femoral head trunnion-taper stability, whereas offset did not affect pull-off force. Multiple head strikes did not add additional stability, as long as a single strike achieved 14 kN force at the mallet-head impactor interface. Insufficient impaction force may lead to inadequate engagement of the trunnion-taper junction.


Assuntos
Artroplastia de Quadril/instrumentação , Cabeça do Fêmur/cirurgia , Prótese de Quadril , Desenho de Prótese , Ligas , Artroplastia de Quadril/métodos , Cromo , Cobalto , Humanos , Fenômenos Mecânicos , Falha de Prótese , Titânio
17.
J Arthroplasty ; 33(9): 2712-2715, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29502964

RESUMO

There has been an increasing use of modularity at the head-neck junction in total hip arthroplasty to more closely mimic the native anatomy, allowing for optimal leg length and stability. Corrosion at this junction in metal-on-polyethylene bearings can lead to an adverse local tissue reaction (ALTR). This increasingly prevalent condition should be considered in the differential diagnosis of hip pain and difficulty ambulating. A recent symposium by the American Academy of Hip and Knee Surgeons described the diagnosis, etiology, management, and prevention of taper corrosion. This article describes the history, physical, plain and advanced imaging findings, laboratory tests, and other diagnoses that should be taken into consideration when diagnosing taper corrosion. The presence of ALTR due to taper corrosion can mimic other diagnoses such as periprosthetic joint infection, instability, or aseptic loosening. Serum metal levels have been found to be the most effective screening tool for identifying corrosion, but other common causes of hip pain and difficulty ambulating should always be ruled out with the use of radiographs and common laboratory techniques before diagnosing ALTR due to corrosion.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Cromo/sangue , Cobalto/sangue , Prótese de Quadril/efeitos adversos , Falha de Prótese , Artrite Infecciosa/etiologia , Corrosão , Diagnóstico Diferencial , Humanos , Metais/sangue , Dor , Manejo da Dor , Medição da Dor , Polietileno , Desenho de Prótese , Radiografia , Reoperação , Líquido Sinovial
18.
J Arthroplasty ; 33(6): 1919-1925, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29606289

RESUMO

BACKGROUND: Currently, there are no universally accepted guidelines on when to obtain metal artifact reduction sequence magnetic resonance imaging (MARS-MRI) in metal-on-metal (MoM) hip resurfacing arthroplasty (HRA) patients. Our primary aims were to identify which patient and clinical factors are predictive of adverse local tissue reaction (ALTR) and create an algorithm for indicating MARS-MRI in patients with Articular Surface Replacement (ASR) HRA. The secondary aim was to compare our algorithm to existing guidelines on when to perform MARS-MRI in MoM HRA patients. METHODS: The study cohort consisted of 182 patients with unilateral ASR HRA from a prospective, multicenter study. Subjects received MARS-MRI at a mean of 7.8 years from surgery, regardless of symptoms. We determined which variables were predictive of ALTR and generated cutoffs for each variable. Finally, we created an algorithm to predict ALTR and indicate MARS-MRI in ASR HRA patients using these cutoffs and compared it to existing guidelines. RESULTS: We found high blood cobalt (Co) (odds ratio = 1.070; P = .011) and high blood chromium (Cr) (odds ratio = 1.162; P = .002) to be significant predictors of ALTR presence. Our algorithm using a blood Co cutoff of 1.15 ppb and a Cr cutoff of 1.09 ppb achieved 96.6% sensitivity and 35.3% specificity in predicting ALTR, which outperformed the existing guidelines. CONCLUSION: Blood Co and Cr levels are predictive of ALTR in ASR HRA patients. Our algorithm considering blood Co and Cr levels predicts ALTR in ASR HRA patients with higher sensitivity than previously established guidelines.


Assuntos
Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Próteses Articulares Metal-Metal/efeitos adversos , Metais/sangue , Algoritmos , Cromo/sangue , Cobalto/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Sensibilidade e Especificidade
19.
J Arthroplasty ; 33(10): 3231-3237, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29958755

RESUMO

BACKGROUND: Adverse local tissue reactions (ALTRs) due to tribocorrosion of head-neck taper junctions in contemporary metal-on-polyethylene (MoP) total hip arthroplasty (THA) are emerging as an important reason for failure requiring revision surgery. This study aimed at: (1) reporting early complication rates and outcome, and (2) identifying risk factors associated with complications of revision surgery for head-neck taper corrosion in patients with MoP THA. METHODS: Forty consecutive revision surgeries in 39 patients (male, 16; female, 23) with MoP THA were evaluated. The follow-up period after revision was a minimum of 14 months (range, 14-45). The indication for revision surgery was the presence of symptomatic ALTR on magnetic resonance imaging (MRI) with elevated metal ion levels. RESULTS: The overall complication rate was 25% and the reoperation rate was 10%. The median serum level of cobalt ions decreased significantly 8.2 µg/L (1.2-56.1 µg/L) pre-revision to 3.1 µg/L (0.2-14.0 µg/L) post-revision (P < .01). High fretting and corrosion grades (Goldberg score ≥ 3) were observed in 82% of retrieved implants. MRI findings of solid lesion(s) with abductor deficiency (P < .01) and intraoperative tissue damage at revision (P = .02) were significantly associated with post-revision complications. CONCLUSION: A high rate of early complications (25%) and re-revisions (10%) was observed after revision of ALTR associated with head-neck taper corrosion. Pre-revision MRI findings of solid lesion(s) with abductor deficiency and intraoperative tissue damage were risk factors associated with the occurrence of a complication after revision surgery. This information provides clinically useful information for clinical decision-making and preoperative counseling of MoP THA patients undergoing revision surgery for head-neck taper corrosion.


Assuntos
Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Reoperação/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/estatística & dados numéricos , Boston/epidemiologia , Cromo/sangue , Cobalto/sangue , Corrosão , Feminino , Prótese de Quadril/estatística & dados numéricos , Humanos , Íons , Imageamento por Ressonância Magnética , Masculino , Metais/sangue , Pessoa de Meia-Idade , Polietileno , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Reoperação/estatística & dados numéricos , Fatores de Risco
20.
J Arthroplasty ; 33(6): 1820-1825, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29429884

RESUMO

INTRODUCTION: Hard-on-hard (HoH) bearing surfaces in total hip arthroplasty (THA) are commonly utilized in younger patients and may decrease mechanical wear compared to polyethylene bearing surfaces. To our knowledge, no study has prospectively compared the 2 most common HoH bearings, ceramic-on-ceramic (CoC) and metal-on-metal (MoM) THA. MATERIALS AND METHODS: We prospectively enrolled 40 patients to undergo an MoM THA and 42 patients to undergo a CoC THA utilizing the same acetabular component. Patients were followed up for a minimum of 2 years. Comparative outcomes included clinical scores, revision or reoperation for any reason, complication rates, and radiographic outcomes. RESULTS: The average follow-up was significantly longer in the CoC cohort (94 vs 74 months; P = .005). The CoC cohort had significantly improved Harris Hip Scores (95 vs 84; P = .0009) and pain scores (42 vs 34; P = .0003). The revision (0% vs 31%; P = .0001), reoperation (7.5% vs 36%; P = .004), and complication rates (10% vs 56%; P = .0001) were significantly lower in the CoC cohort. There were no statistically significant differences in radiographic parameters. CONCLUSION: The clinical outcomes in the CoC cohort exceeded the MoM cohort. It is unlikely that another prospective comparative study of HoH THAs will be conducted. Our midterm results support the use of CoC THA as a viable option that may reduce long-term wear in younger patients. Close surveillance of MoM THA patients is recommended considering the higher failure and complication rates reported in this cohort.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/estatística & dados numéricos , Próteses Articulares Metal-Metal/estatística & dados numéricos , Acetábulo , Idoso , Cerâmica , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Próteses Articulares Metal-Metal/efeitos adversos , Pessoa de Meia-Idade , Polietileno , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Reoperação